Home
GE EWSW & EESW Installation Guide
Contents
1. recessed mounted outlet box is to position back cover over the box and securely mount with lag bolts not provided through the holes provided in the back cover see Figure 1 FIGURE 1 MOUNTING Remove the back cover by loosening the two security screws and sliding the cover downward off of the hinges e A gasket is provided on the back of the unit to provide water and dust protection when mounting to smooth surfaces To maintain IP65 dust and water protection of the unit on textured surfaces block brick etc caulk the back of housing with generic non hardening sealant not provided across the top bottom and both sides Pull wires from outlet box into the cover e Attach the cover to the wall or outlet using the holes in the cover as a drill template Alternately the mounting diagram in these instructions may be used as a drill template e Slide fixture onto the cover hinge e Connect wires Close the fixture and secure with the two security screws MAINTENANCE CLEANING WARNING Risk of electric shock Make certain power is off before attempting any maintenance maintain high efficiency of the lens occasional cleaning of the outer lens surface may be needed with frequency dependant on local conditions e Use q mild soap or detergent which is essentially neutral pH pH approximately 6 to 8 non abrasive and which contains no chlorinated or aromatic
2. is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense imagination at work e This luminaire is designed for outdoor lighting applications and should not be used in areas of limited ventilation or in high ambient temperature enclosures e Best results will be obtained if installed and maintained according to the following recommendations e This luminaire is designed to operate in ambient temperatures ranging from 40 C to 50 C and to be mounted horizontally on a vertical wall with LEDs facing down SPECIFICATIONS e Weight Maximum weight 29 lbs 13 kgs e IP Rating Optical 65 Standard Electrical Enclosure UL 1598 Wet Location Rated UNPACKING e This luminaire has been properly packed so that no parts should have been damaged during transit e Inspect to confirm 2 HANDLING Damage may occur if luminaire is improperly handled outside of pack e Do not impact or stack luminaire after removal from package OUTLET BOX MOUNTING WARNING Risk of injury or damage Unit will fall if not installed properly Follow installation instructions The luminaire can be mounted to a suitable recessed mounted outlet box 3 1 2 in or 4 in octagonal The back cover may be attached to the outlet box with two 10 24 screws not provided approximately 1 25mm long An alternate method of mounting the back cover over
3. hydrocarbons e Wash thoroughly using a soft cloth e Rinse with clean cold water and wipe dry 5 STORAGE Prior to installation units should NOT be stored outside in corrugated boxes cardboard boxes alone e Until installation all units should be placed in a covered dry storage area The storage area should not exceed 40 C 40 F to 50 1227 This can be preferably in a roofed area or with a tarp that is secured in such a way to keep water off of the corrugated boxes cardboard boxes MOUNTING DIAGRAM 4 4 in 112mm 3 1 2 Octagonal J box ctagonal J box Lee ed O These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting GE Lighting e 1 888 MY GE LED 1 888 69 43 533 e www gelighting com GE Lighting is a subsidiary of the General Electric Company Evolve and the GE brand and logo are trademarks of the General Electric Company 2013 GE Lighting Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 199 Rev 09 18 13 English GE Lighting Guide d instal
4. recevoir le moindre coup ni tre empil e MONTAGE SUR BOITIER DE PRISE AVERTISSEMENT Danger de blessure ou de dommage mat riel L appareil tombera s il est mal install Suivez les instructions d installation e Ce luminaire peut se monter sur un bo tier de prise en castr convenable octogonal de 3 1 2 ou 4 pouces e Le couvercle arri re peut se fixer sur le bo tier de prise avec deux vis de 10 24 non fournies d environ 1 25 mm de long e Une autre m thode pour monter le couvercle arri re sur un bo tier de prise encastr est de le positionner soigneusement dessus et de bien le fixer avec des tire fond fournis au travers des trous fournis dans le couvercle arri re voir la Figure 1 FIGURE 1 ASSEMBLAGE e tezle couvercle arri re en desserront les deux vis de s curit et en glissant le couvercle vers le bos pour le sortir des charni res e Un joint est fourni au dos de l appareil pour assurer une protection contre l eau et la poussi re en cas mon tage sur une surface lisse Pour garder une protection de l appareil contre poussi re et eau de niveau d tanch it IP65 sur des surfaces textur es bloc brique etc endui sez le dos du carter avec un mastic g n rique ne durcis sant pas non fourni en en mettant le long du haut du bas et des deux c t s e Tirez les fils du bo tier de prise dans le couvercle e Fixez le couvercle sur
5. GE Lighting Installation Guide GEH 6007A Evolve LED Area Light Wall Pack amp Egress EWSW amp EESW BEFORE YOU BEGIN Read these instructions completely and carefully Save these instructions for future use A WARNING Risk of electrical shock Disconnect power before servicing or installing product A WARNING Risk of injury or damage Unit will fall if not installed properly Follow installation instructions WARNING Risk of fire Use supply wire specified on nameplate This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A RFLD complies with the Canadian standard ICES 003 Ce DEFR de la classe A est conforme la NMB 003 du Canada Note This equipment has been tested and found to comply with the limits for a Class digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area
6. lation GEH 6007A Luminaire de zone a DEL Evolve Ensemble mural et de sortie EWSW et EESW AVANT DE COMMENCER Lisez compl tement et attentivement ces instructions Conservez ces instructions pour une utilisation future AVERTISSEMENT Risque de commotion lectrique D connectez l alimentation lectrique avant d installer ou r parer ce produit AVERTISSEMENT Danger de blessure ou de dommage mat riel L appareil tombera s il est mal install Suivez les instructions d installation AVERTISSEMENT Risque de d part d incendie N utilisez que les fils d alimentation sp cifi s sur la plaque signal tique Cet appareil est conforme aux exigences de la partie 15 des r gles de la FCC Son utilisation est sujette aux conditions suivantes 1 cet appareil ne doit pas causer d interf rences nuisibles 2 cet appareil doit accepter toutes les interf rences re ues y compris celles pouvant causer un fonctionnement ind sirable Ce DEFR de la classe est conforme la NMB 003 du Canada Remarque Cet appareil a t test et reconnu conforme aux limites tablies pour les appareils num riques de classe selon la partie 15 des r gles de la FCC Ces limites sont con ues pour assurer une protection raisonnable contre les interf rences nuisibles dans un environnement commercial Cet appareil g n re utilise et met de l nergie sous forme de radiofr quences de sorte que si son installa
7. le mur ou le bo tier de prise en utilisant les trous du couvercle comme gabarit de percage Sinon vous pouvez aussi utiliser le sch ma de montage de ce document comme gabarit de percage e Faites glisser l appareil sur la charni re de couvercle Raccordez les fils e Fermez l appareil et fixez le avec les deux vis de s curit 5 ENTRETIEN NETTOYAGE Risque de commotion lectrique Assurez vous que l alimentation lectrique est bien coup e avant toute inter vention e Pour conserver l efficacit du module optique nettoyez p riodiquement la surface ext rieure de la lentille la fr quence des nettoyages d pendra des conditions locales e Utilisez un savon doux ou un d tergent essentiellement neutre ayant un pH d environ 6 8 sans abrasif et sans hydrocarbure chlor ou aromatique e Lavez fond avec la solution de nettoyage en utilisant un chiffon doux Rincez avec de l eau froide et propre puis essuyez ENTREPOSAGE e Avant leur installation les luminaires ne doivent PAS tre entrepos s l ext rieur dans de simples bo tes en carton e Jusqu leur installation tous les luminaires doivent tre conserv s dans un lieu de stockage couvert et sec La temp rature du site de stockage doit se situer entre 40 C et 50 40 et 122 F Conservez les pr f rablement sous un toit ou sous une b che install e solidement de fa on ce que l eau ne puisse atteindre
8. les bo tes en carton SCH MA MONTAGE 4 4 po 112 mm Boitier 1 3 po 33 J octogonal de mm 3 1 2 po 3 9 po 73 mm Boitier en J octogonal de Z Ces instructions n ont pas pour but de couvrir tous les d tails et toutes les variantes de l quipement ni de r pondre tous les impond rables possibles en relation avec l installation le fonctionnement et l entretien Si vous d sirez plus d informations ou si des probl mes particuliers surviennent qui ne sont pas couverts suffisamment pour les besoins de l acheteur le sujet doit tre soumis GE Lighting GE Lighting e 1 888 MY GE LED 888 69 43 533 e www gelighting com GE Lighting est une filiale de la General Electric Company Evolve ainsi que la marque et le logo GE sont des marques commerciales d pos es de la General Electric Company 2013 GE Lighting Les informations fournies ici sont susceptibles de changer sans pr avis Toutes les donn es sont des valeurs de conception ou caract ristiques lors de leur mesure en conditions de laboratoire 35 201578 199 R v 09 18 13 French
9. tion et son utilisation ne sont pas conformes la notice d utilisation il peut tre la cause de parasites nuisibles aux communications radio L utilisation de cet quipement dans une zone r sidentielle risque fort de causer des interf rences nuisibles auquel cas l utilisateur devra corriger le probl me ses propres frais imagination at work Ce luminaire a t con u pour une utilisation l ext rieur et ne doit pas tre employ sur un site mal ventil ni dans un endroit clos o la temp rature ambiante peut tre lev e Pour obtenir des performances optimales il doit tre in stall et entretenu conform ment aux recommandations suivantes e Ce luminaire est con u pour fonctionner dans des temp ratures ambiantes allant de 40 50 C et tre mont horizontalement sur un mur vertical avec ses diodes lectroluminescentes dirig es vers le bas SPECIFICATIONS e Poids Poids maximal de 29 Ibs 13 kg e Classification IP Module optique 65 boitier lectrique standard Homologation UL 1598 pour environnement mouill DEBALLAGE e Celuminaire a t soigneusement emball pour qu aucune ne subisse de dommages durant le transport e Proc dez une inspection pour vous en assurer 2 MANUTENTION Sile luminaire est incorrectement manipul hors de son emballage il risque d tre endommag Lorsque le luminaire est sorti de son emballage il ne doit pas
Download Pdf Manuals
Related Search
Related Contents
Powermatic PF-BS User's Manual Service Manual Manuale installazione e Manutenzione Serbatoi COBWEBSERVER isofloc AG – VR-Protokoll 1.10 – 17.02.10 Grid-based Collaboration in Interactive Data USER MANUAL - sertech indonesia Copyright © All rights reserved.
Failed to retrieve file