Home
GE DPGT750GCWW User's Manual
Contents
1. 750GC GE Profile Harmony King size 7 3 Cu Ft Capacity Gas Dryer For complete information see installation instructions packed with your dryer Ducting Materials For best performance this dryer should be vented with 4 diameter all rigid metal exhaust duct If rigid metal duct cannot be used then UL listed flexible metal semi rigid ducting can be used Kit WX08X10077 In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foil type duct A UL listed flexible metal foil type duct may be used ONLY in installations where rigid metal or flexible metal semi rigid ducting cannot be used AND where a 4 diameter can be maintained throughout the entire length of the transition duct Please see installation instruction packed with your dryer for complete instructions when using flexible metal foil type ducting Exhaust Length Calculation 1 Determine the number of 90 turns needed for your installation If you exhaust to the side or bottom of dryer add one turn 2 The maximum length of 4 rigid aluminum or galvanized duct which can be tolerated is shown in the table A turn of 45 or less may be ignored Two 45 turns within the duct length should be treated as a 90 elbow A turn over 45 should be treated as a 90 elbow Dryers must be exhausted to the outside Caution For personal safety do not terminate exhaust into a chimney under any enclosed house floor
2. DPGT 750GC GE Profile Harmony King size 7 3 Cu Ft Capacity Gas Dryer Dimensions and Installation Information in inches Exhaust Options When viewed from the front of the unit exhaust 3 way via rear left and bottom Dryer is shipped exhausted to the rear Alternate exhausting knockouts are supplied Left or bottom exhaust requires a conversion kit Gas An individual properly grounded branch circuit with a three prong grounding type receptacle protected by a 15 or 20 amp circuit breaker or a time delay fuse is required Gas Dryer Electric Rating 120V 60Hz 6A Gas BTU HR 25 000 Factory equipped for natural gas Tested for LP gas LP gas supply requires a conversion kit Check installation instructions for correct kit and have a qualified gas technician install a conversion kit See dryer ducting information for proper installation Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer For answers to your Monogram GE Profile or GE appliance questions visit our website at ge com or call GE Answer Center service 800 626 2000 imagination at work i x 22 1 2 lt 29 li lt _ 26 1 2 Side View x 27 Rear View Specification Revised 5 09 gt SB 270183 DPGT
3. crawl space or into an attic since the accumulated lint could create a fire hazard or moisture could cause damage Never terminate the exhaust into a common duct or plenum with a kitchen exhaust since the combination of lint and grease could create a fire hazard Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts bird nesting etc The wall cap must also be located at least 12 above the ground or any other obstruction with the opening pointed down Dryer Elbow Kit Pub No 14 A003 is available at additional cost For use with side or bottom exhaust options For more information on venting kits and accessories please call 1 800 GE CARES imagination at work Special Installation Requirements Alcove or Closet Installation e If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back e The dryer MUST be exhausted to the outside e Minimum clearances between dryer cabinet and adjacent walls or other surfaces are 0 either side 3 front and rear e Minimum vertical space from floor to overhead cabinets ceilings etc is 52 e Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed e No other fuel burning appliance shall be installed in the same cl
4. nd Dryer Control Panels Can be Easily Interchanged Without Any Loss of Function Allowing Installation Flexibility e Multiple Dry Cycles with 6 Custom Cycles and Adaptive Logic System e Dual Electronic Thermistors e Dual Motors e Dryer Interior Light e Model DPGT750GCPL Dark platinum e Model DPGT750GCWW White on white B imagination at work Specification Revised 5 09 270183
5. oset with a gas dryer Bathroom or Bedroom Installation e The dryer MUST be exhausted to the outdoors e The installation must conform with the local codes or in the absence of local codes with the National Electric Code and National Fuel Gas Code ANSI Z223 for gas dryers Minimum Clearances other than Alcove or Closet Installation e Minimum clearances to combustible surfaces are 0 both sides 3 rear Dryer Exhausting Information Use metal duct only vertical and horizontal ducting f A O Maximum length of 4 A dia rigid metal duct ba J Number of Domestic 2 1 2 90 dryer models turns 7 5 and 7 3 cu ft capacity electric and gas dryers Specification Revised 5 09 270183 DPGT 750GC GE Profile Harmony King size 7 3 Cu Ft Capacity Gas Dryer Features and Benefits e Receives Load Information Electronically from the Washer WPGT9350 e King size 7 3 Cu Ft Capacity Dryer with Stainless Steel Drum and Deluxe Dryer Rack e DuoDry System Quickly and Consistently Dries All Types of Clothes e LCD Electronic Controls with Time Display Status Lights and Cycle Countdown with LCD Indicators e Variable Heater Delivers Constant Heat with No On off Cycling for Optimal Drying Results e Adaptive Venting System Delivers Exceptional Drying Performance e Delicate Cycle with Extra Low Setting Maintains an Average Fabric Temperature of 125 F to Protect Fine Handwashables e Reversible Washer a
Download Pdf Manuals
Related Search
Related Contents
Corso Windows XP Eee Slate Benutzerhandbuch Tecumseh AJA2429ZXAXB Performance Data Sheet TransactionCentre - Módulo Client .exe Manual de Instalação Mai a c d b f g h i j l m k - Migros Políticas públicas e patrimônio cultural Orangenschäler Manuel d`utilisateur Handbuch - HiFi 強化ガラス t5`0 フ ロス ト仕上げ 3NR-CY-S (3 Copyright © All rights reserved.
Failed to retrieve file