GE BL Series Installation Guide
Contents
1. fix bracket to grid Risk of Injury Improper mounting bracket installation may cause injury or property damage Troubleshooting Symptom Solution Luminaire does not light e Check input voltage and check power supply input output connections e Check circuit breaker Luminaire is dim e Maximum recommended supply wire length is exceeded Refer to EP147 installation guide for Maximum Driver Remote Mounting Distance Luminaire is blinking e Ensure power supply temperature does not exceed its maximum rating e Refer to the tc point located on power supply Luminaire does not dim e Check dimming wire connection This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This Class A RFLD complies with the Canadian standard ICES 003 Ce DEFR de la classe A est conforme t la NMB 003 du Canada Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cau
2. on wire connectors min 18 AWG e M3 wingnut 8 pieces e UL cUL approved conduit fittings for 1 2 conduit trade e Ceiling grid safety screw for grid and bracket fixing 4 pieces size 2 pieces e Primary diffuser e Optional low glare diffuser with protective film imagination at work Diffuser Installation Carefully unpack unit from its packaging Properly Remove end cover closest to the cable glands inspect for defects before installing Wear Retain star washer for reinstalling end cover work gloves to prevent dirt and oil from being transferred to the luminaire One diffuser gt Two diffusers ottom Diffuser with green film faces up Remove before sliding in D One diffuser Slide diffuser into base of luminaire 3B Two diffusers Slide both diffusers into base of luminaire making sure the diffuser with the green protective film is placed on the bottom Prepare Electrical Wiring Electrical Requirements e The LED driver must be supplied with 100 277 VAC 60 Hz and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker Use min 600V 75 C supply conductor Grounding Instructions e The grounding and bonding of the overall system shall be done in accordance with National Electric Code NEC Article 600 and local codes Electrical Connections 1 Remove knockout closure to insert AC line Optionally remove both knockout closures if installing a dimm
3. GE Installation Guide Lighting Solutions Lumination LED Luminaires BL42 BL44 and BL45 Series Features e Long life 50 000 hour rated life e 5 year warranty e Dry location rated BEFORE YOU BEGIN Read these instructions completely and carefully WARNING AVERTISSEMENT RISK OF ELECTRIC SHOCK RISQUES DE DECHARGES ELECTRIQUES e Turn power off before inspection installation or removal e Coupez l alimentation avant d inspecter installer ou d placer le luminaire e Properly ground electrical enclosure e Assurez vous de correctement mettre la terre le bo tier d alimentation lectrique RISK OF FIRE RISQUES D INCENDIE e Follow all NEC and local codes e Respectez tous les codes NEC et codes locaux e Use only UL approved wire for input output connections e N utilisez que des fils approuv s par UL pour les entr es sorties de Minimum size 18 AWG 0 75mm connexion Taille minimum 18 AWG 0 75mm e Type IC inherently protected e Type IC protection inh rente Save These Instructions Use only in the manner intended by the manufacturer If you have any questions contact the manufacturer Provided in the package are Tools and components required e Luminare e For end cover install Philips headed screwdriver e Universal mounting bracket 4 pieces e Rigid RMC or flexible FMC metal conduit for supply connection e M3x12mm screws for mounting bracket installation 8 pieces e UL cUL approved twist
4. grey DALI 1 10V DALI 2 violet white DALI 1 10V O 1 10V wiring diagram O DALI wiring diagram Line Ground su Neutral Neniel Switched Hot Ground r PSU e aa EcoSystem 1 DALI 1 10V EcoSystem 2 DALI 1 10V EcoSystem 1 f EcoSystem 2 Neutral Lutron wiring diagram Luminaire Installation With the supplied universal bracket the product is compatible with the following USG type grids Dx DXI DXT DXF DXM Reference diagram right to determine which hole to use for a given grid Safety screw holes One is needed O more are optional 1 Slide four M3x12 bracket mounting screws into Fasten mounting brackets over screws by using housing groove on each side eight screws per two M3 wingnuts for each bracket but do not housing are required If the screw head cannot tighten them at this point Note that bracket flaps pass through end cover groove remove end have to be aligned with the groove covers and slide the screw head directly into the housing groove then re install end covers Always use two screws per bracket 4 Fasten the wingnuts of the mounting brackets by hand being careful not to strip the threads One safety screw is mandatory additional screws are optional O For added safety use additional celing grid screws to permanently
5. ing line Dimming line optional 3 Optional f using a dimmer connect black and red wires of the dimming line to the PSU dimming wires with twist on connectors Use the appropriate wires for your dimming type according to diagrams below Wiring for Lutron Controller two white neutral input wires of the LED Driver using 18 14 AWG 0 82 2 08 mm twist on wire connectors Connect AC line green ground wire to Troffer ground wire using twist on connectors neutral input wires of the LED Driver using 18 14 AWG 0 82 2 08 mm twist on wire connectors Connect AC line green ground wire to Troffer ground wire using twist on connectors Star washer 0 Replace cover using at least one star washer under countersunk screw head Lutron dimming wires For Lutron dimming connect black and red wires of the dimming line to the two purple Lutron dimming wires with twist on connectors Wiring Diagrams Optional Installation 1 10 Volt Dimming or DALI Lighting Controller Follow diagram A for 1 10V diagram B for DALI or diagram C for Lutron dimming At output side of LED driver make appropriate connections using twist on wire connectors Follow lighting controller installation instructions Line ine Line line Neutral Neutral Neutral Neutral 1 10V z Groug 4 Ground PSU ea Ground Ground PSU oN 1 10 violet DALI 1 violet DALI 1 10
6. se harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions LLC is a subsidiary of the General Electric Company Lumination is a trademark of GE Lighting Solutions LLC The GE brand and logo are trademarks of the General Electric Company 2013 GE Lighting Solutions LLC Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 1326613 IND034 051713