1. 7 Slide the side panel toward the front of the case about inch then lift the panel away from the server 30 www gateway com Opening the server case 8 If your server has an air duct pull the tab on the right until it releases the duct from the server then lift the duct away from the server i i H i EH A www gateway com 31 Chapter 4 Installing Components Closing the server case gt To close the server case 1 For more stability place the server on its side 2 Make sure that all of the internal cables are arranged inside the case so they will not be pinched when you close the case 3 Replace the air duct if one came with your server 4 Align the side panel s top and bottom tabs into the case notches then slide the side panel toward the back of the case until the back of the side panel is flush with the back of the case 5 Tighten the three captive thumbscrews that secure the front of the cover to the server case Thumbscrews 6 Set the case upright 32 www gateway com Closing the server case 7 Align the notch in the bottom of the front cover with the rail on the front of the case then swing the cover against the case 8 Lock the front cover 9 Reconnect the power cords and all other cables www gateway com 33 Chapter 4 Installing Components Installing drives Your server s basic configuration includes one CD drive and one 3 5 inch diskette drive Your server also
2. 0 a a E RR eee 98 A Server Specifications 0 0 c cece eee 99 System specifications isses en 100 System board specifications 060 eee 101 Environmental specifications iler 102 Video specifications s ux nes dap Rep RR Bea NU ER EE EET Rus 103 Resolution support 0 0 cece rne 103 Electronic specifications ersa rin 0 c eee eee 104 Memory mapzs ince bribe baed pede eeu eee bee Seb abh oth A 104 Interr pts abs te EER AVUNEX OE ges MERE BORED AR UR 104 PGI interrupt routing vues eho See ee Reese Pe eg E Erie em 105 Additional specifications 00 E EEE a IIR 106 B BIOS SeUings edo et esca e et ead hae tals rs 107 C Safety Regulatory and Legal Information 111 Index csetera re Eten daas uta doeet du cede 119 Checking Out Your Gateway Server Read this chapter to learn m Where drives ports jacks and controls are located m Where system board components are located m What help resources are available Chapter 1 Checking Out Your Gateway Server Front Diskette drive a CD drive Cover release E Cover release id ee atch Additional drive E bays Power button Reset button _ Power indicator A 0 Hard drive indicator Key lock Sj USB ports 2 www gateway com Chapter 1 Checking Out Your Gateway Server Back Power connector Power connector USB port
3. 7 Ifyou are replacing a drive disconnect the old drive s cables 38 www gateway com Installing drives 8 If you are removing a drive from one of the top two bays first remove the 3 5 inch diskette drive so you can reach the 5 25 inch drive s release latch 9 Press the old drive s release latches against the drive then pull the drive out of the bay www gateway com 39 Chapter 4 Installing Components 10 Remove the screws that secure the mounting rails to the old drive then use the screws to attach the rails to the new drive i a Screw Screw Screws for mounting the rails onto most tape drives are stored in the case near the full length card retention clips Tape drive screws 11 set any jumpers on the new drive See the drive s documentation for further instructions 12 Slide the new drive into the drive bay until the drive rails snap into place 40 www gateway com Installing drives 13 Connect the drive cables For more information see the drive s documentation 14 Follow the instructions in Closing the server case on page 32 www gateway com 41 Chapter 4 Installing Components Installing a SCSI hard drive Use this procedure to add or replace hard drives in the hot swap bay Your server supports up to eight 1 inch high 3 5 inch SCA SCSI hard drives You can purchase additional SCSI drives through your Gateway sales representative Important The numbers on the left si
4. Gateway 980 Server user sguide Customizing Troubleshooting CG Gateway Contents 1 Checking Out Your Gateway Server 1 onec Er 2 Back coe ses Hocico otis ected si bedun du Venen LAS DH Syed dct oce e Rent D dun Yes 4 NENTS o caer ct HE E RUN SURE THEE E REDI 5 System board erraia ean ua E E a hmmm 6 HI 4 cT 6 Right side ue eer eodem oe cem ate A Dee t e alee ae 7 Getting Help 1x52 rs oos E dee rs Rt eis 8 Server Companion CD 00000 se 8 Gateway Web site 0 0 ene 8 2 Setting Up Your Server sLslsuusus 9 Setting up the hardware 0 0 00 cect ns 10 Converting to a rackmount server 000 anaana eese 10 Protecting from power source problems 000 0c eee eee eens 11 Starting your server 0 0 eee 13 Understanding the power on self test 00 e eee ee 14 Turning off your server suie rrie a EE tees 15 Setting up the operating system 00 00 c cee 16 3 Maintaining Your Server susuuueeesseese 17 Caring for your server 0 0 nhe 18 Cleaning your server llisllellellel hr 18 Preparing for system recovery llseeeeee rens 21 Recording the BIOS configuration 0 00 c cece ee 21 System administration uaaa aaaea eae 22 Gateway Server Manager 0000 e eee eee 22 Server security coss Quse oo E uH ERN Res Des Ha a eee sh eee a
5. Whenever a recoverable error occurs during the power on self test POST the BIOS displays an error message that describes the problem The BIOS also sounds a beep code one long tone followed by two short tones during POST if the video configuration fails a faulty video controller or if an expansion card is not functioning correctly A PCI expansion card for example a RAID controller can also issue audible errors by itself usually consisting of one long tone followed by a series of short tones For more information on the beep codes issued check the documentation for that device Several POST routines issue a POST terminal error and shut down the system when they fail Before shutting down the system the terminal error handler sounds a beep code one long tone and a series of short tones that identifies the test point error If POST completes normally the BIOS issues one short beep before passing control to the operating system Beeps 10 11 BIOS Description The memory refresh circuitry on the system board is faulty Parity error in the first 64 KB of memory Memory failure in first 64 KB Memory failure in first 64 KB of memory or Timer 1 on the system board is not functioning A processor on the system board generated an error The keyboard controller 8042 may be defective The BIOS cannot switch to Protected mode The processor generated an exception interrupt The server s video memory is fau
6. m Make sure that the electrical outlet is working by plugging a working device such as a lamp into the outlet then turning it on to test the outlet m Open your server and make sure that the power supply cable and power button cable are connected correctly to the system board When you turn on the server it makes several short beeps m The short beeps indicate the server has encountered some type of error See Beep codes on page 86 Processor Your server does not recognize a new processor m Make sure that the processor is fully seated in its socket The processor should be recognized automatically if it is installed correctly m Ifyouhave upgraded your server from one processor to two you may need to reconfigure your operating system so it recognizes the additional processor For more information see your operating system s documentation m Make sure that a voltage regulator is installed for each processor on the system board 95 Chapter 6 Troubleshooting Telephone support Before calling Gateway Technical Support If you have a technical problem with your server follow these recommendations before contacting Gateway Technical Support 96 Make sure that your server is connected correctly to a grounded AC outlet that is supplying power If a peripheral device such as a keyboard or mouse does not appear to work make sure that all cables are plugged in securely If you have recently installed hardware or soft
7. n Resetting BIOS passwords To reset BIOS passwords you must reset and clear all BIOS settings To reset BIOS passwords follow the instructions in Resetting the BIOS on page 78 www gateway com 79 Chapter 5 Using the BIOS Setup Utility 80 www gateway com Troubleshooting Read this chapter to learn how to m Interpret error messages and codes m Troubleshoot m Get telephone support and training If the suggestions in this chapter do not correct the problem see Telephone support on page 96 for more information about how to get help 81 Chapter 6 Troubleshooting Safety guidelines While troubleshooting your server follow these safety guidelines 82 Never remove the side panel while your server is turned on and while the modem cable and the power cords are connected Do not attempt to open the monitor To do so is extremely dangerous Even if the power is disconnected energy stored in the monitor components can be dangerous Also opening the monitor voids its warranty Make sure that you are grounded correctly before opening the server case For more information about preventing damage from static electricity see Preventing static electricity discharge on page 27 After you complete any maintenance task where you have to open the server case make sure that you close the case tighten any screws then reconnect all cables before you restart your server Warning To avoid bodily injury do
8. Check BIOS settings to make sure that they detect the server s new hardware then save your changes if any and close the BIOS Setup utility www gateway com Replacing a fan Replacing a fan The pictures in this procedure show the hot swap bay fan All case fans can be replaced in the same manner Important Make sure that you replace a fan with an identical replacement fan The arrow on each fan indicates the direction of its air flow and the arrow should point toward the rear of the case gt To replace a fan 1 Follow the instructions in Preventing static electricity discharge on page 27 2 Follow the instructions in Opening the server case on page 28 C Unplug the fan from the system board 4 While pressing the locking clip slide the fan away from the system board then pull it away from the case System board tray thumbscrew gateway com 69 Chapter 4 Installing Components 5 Insert the new fan s mounting posts into the fan mounting slots then slide the fan down until it snaps into place 6 Reconnect the fan to the system board Rear fan connector Hot swap bay fan connector PCI fan connector f Follow the instructions in Closing the server case on page 32 70 www gateway com Replacing the CMOS battery Replacing the CMOS battery If the server clock does not keep time or the settings in the BIOS Setup utility are not saved when you turn off the server replace the CMOS batt
9. 22 Using your Server Companion CD sasaaa aaaea 24 4 Installing Components sseeeeeesese 25 Preparing to install components llleleleele eee 26 Selecting a place to work 000 ceca 26 Gathering the tools you need 000 c cee eae 26 Preventing static electricity discharge 0 eee eee 27 Opening the server case 0 0 cee rn 28 Closing the server case 0 0 ccc tte 32 Installing drives ssec mede be eee ends baer eee Pe 34 Installing an IDE drive llllselllere B BBBR6M M 35 Installing a SCSI hard drive liliis 42 Installing memory uem dem t Rm mm ym re eee 45 Installing PCI expansion cards lsllssleseeselel eh 47 Installing a processor sororia terade ee e E IRI 52 Installing a voltage regulator 0 eee 56 Replacing the power supply 000 eee eee tetas 57 Replacing the SCSI backplane 0000 e eee eee ee 60 Replacing the system board 0 cee eee 66 Replacing Atami seg 2 ssi cd eee Re SRG a wenn ea ead wee ewe oat aes 69 Replacing the CMOS battery 0 0 00 cece eee 71 Using the BIOS Setup Utility 22 02 75 Opening the BIOS Setup utility liliis 76 Updating the BIOS ii vus ur khhe reb EPA RD eae te bees dea ea ERE as 77 Recovering the BIOS lsussssseeseeeeeeee ne 77 Resetting the BIOS ee rh E EP RV ERR eS RE TEE UE
10. A tape drive cleaning cartridge if a tape drive is installed A CD drive cleaning kit Caring for your server Cleaning tips m Always turn off your server and other peripheral devices before cleaning any components Warning When you shut down your server the power turns off but some electrical current still flows through your server To D avoid possible injury from electrical shock unplug the power cords and all other cables connected to the server m Use a damp lint free cloth to clean your server and other parts of your server system Do not use abrasive or solvent cleaners because they can damage the finish on components m Keep the cooling vents free of dust With your server turned off and unplugged brush the dust away from the vents with a damp cloth but be careful not to drip any water into the vents Cleaning the keyboard You should clean the keyboard occasionally by using an aerosol can of air with a narrow straw like extension to remove dust and lint trapped under the keys If you spill liquid on the keyboard turn off your server and turn the keyboard upside down to let the liquid drain Let the keyboard dry completely before trying to use it again If the keyboard does not work after it dries you may need to replace it Keyboard damage resulting from spilled liquids is not covered by your warranty Cleaning the screen If your computer screen is a flat panel display use only a damp soft cloth to clean it
11. Gateway Flex Case Gateway Gaming Ware Gateway GoBack Gateway Gold Gateway Learning Ware Gateway Magazine Gateway Micro Server Gateway Money Ware Gateway Music Ware Gateway Networking Solutions Gateway Online Network O N solution Gateway Photo Ware Gateway Professional PCs Gateway Profile Gateway Solo green stylized GATEWAY green stylized Gateway logo Gateway Teacher Ware Gateway Video Ware HelpSpot InforManager Just click it Learn 9 Gateway Kids BackPack SERVE TO ORDER Server Watchdog SpotShop Spotshop com and Your Ware are trademarks of Gateway Inc Intel Intel Inside logo and Pentium are registered trademarks and MMX is a trademark of Intel Corporation Microsoft MS MS DOS and Windows are trademarks or registered trademarks of Microsoft Corporation All other product names mentioned herein are used for identification purposes only and may be the trademarks or registered trademarks of their respective companies 118 Index Numerics 3 5 inch drive adapter 36 5 25 inch drive installing 35 location 2 A accessories safety precautions 112 add in card see card adding see installing administrator password see supervisor password Advanced menu BIOS Setup utility 76 108 B backplane installing 60 location 5 battery location 7 replacing 71 troubleshooting 85 beep codes 86 BIOS recovering 77 resetting 78 resetting passwords 79 settings 107 troubleshooting 87 updating 77 BIOS
12. Ma eed 78 Resetting BIOS passwords 0 000 eee tees 79 Troubleshoolini eor tee ots eho a as S D ERE eden See ee 81 Safety guidelines n nesi rri oie na E AAE EA R E e A e A E 82 Error messages eel deena aa a O a a e er e deer ce a een es 83 Troubleshooting i ez cedo eso Pine Shake abere exo SPA Eat 85 FirSE Steps ica sni ead ga ek Igeu ee iad eee pd s 85 Battery replacement r HEEE cee eh 85 Beep codes zssLonxevpkiRuleg ekle pi eps 84ned k ad bela Get ale E 86 BIOS 5 5 sc uo db E el ahead ert Ao obere Ex abad d 87 CD diive 3 s or oud cce aeter eiat pts ue NU a ME DR 88 Diskette drive scotia le die ES aye ede bI ERG ER 88 Expansion Cards 4 csse c VERDE bh de Pwd ee bd te eee e 89 Hard drive i uei de Sree a ete pada Panay Ban Sauk Risers wate Ub EV 89 Intetriet Lion qu sui Avante ee sews aie estates hed Conve eas 91 Keyboard vide RT RES RR a tees RE EE 92 MEMON e csipimed neci zDew when nryO5gke 4X4 TRY RP RR URP ed ode dt 92 Modem telephone dial up sesseeee B 92 Monitor 0o caliente Pies ee a a eae este en a ee REM MIS E IL 94 POWOI 23 1o ERE EE EPA GERA Got wey RUNE TERES EU ET ENDS 95 PIOCOSSO ost ree n RR es a ee ld be ke Pe we Ea rub te UR EDEN us 95 Telephone SUPEO e aad howe Rae RR PEG XN bed PX ERA 96 Before calling Gateway Technical Support 00000 cee eens 96 Telephone Support sessing e E aid See Pea Hane UE Y Ma RU 97 Tutoring and training 0
13. Never spray water directly onto the screen Warning The computer screen is made of specially coated glass and can be scratched or damaged by abrasive or D ammonia based glass cleaners OR If your computer screen is not a flat panel display use a soft cloth dampened with glass cleaner to clean the screen Never spray cleaner directly onto the screen 19 Chapter 3 Maintaining Your Server Cleaning the tape drive If you use a tape drive to back up your files regular maintenance will lengthen the life of the drive To maintain the drive s reliability m Clean the drive monthly with the cleaning cartridge included with the drive m Remove the tape from the drive whenever the drive is not in use 20 Preparing for system recovery Preparing for system recovery If your system files are corrupted you may not be able to start the server from the hard drive Startup diskettes are diskettes that let you start the server and attempt to fix the problem See your operating system s documentation or online help for instructions on creating startup diskettes Some operating systems also let you create an emergency repair diskette to back up critical operating system files See your operating system s documentation or online help for instructions on using an emergency repair diskette Recording the BIOS configuration To help keep track of your custom changes to BIOS settings and to prepare for system recovery you should record
14. Setup utility 75 Advanced menu 108 Boot menu 110 Main menu 108 menus 76 108 navigating through 76 opening 76 passwords 22 79 Power menu 110 recording configuration 21 Security menu 110 settings 107 troubleshooting 87 boot device 14 menu 14 Boot menu BIOS Setup utility 76 110 C cable clips location 5 card fan 5 7 installing 47 paired slots 47 reseating 47 retention clip 5 retention cover 5 retention cover lever 4 retention cover release latch 5 slot location 6 47 troubleshooting 89 case closing 32 opening 28 CD Server Companion 24 troubleshooting 88 CD drive installing 35 location 2 troubleshooting 88 cleaning keyboard 19 screen 19 119 servers 18 tape drive 20 closing case 32 CMOS battery see battery conditioner line 12 configuration jumper 7 connections auxiliary power 7 diskette drive 7 fans 6 7 front panel 7 IDE 7 intrusion switch 7 keyboard 4 LAN 4 lock slot 4 main power 7 monitor 4 mouse 4 network 4 parallel 4 power 4 7 power supply manageability 7 RJ 45 4 SCSI 7 serial 4 USB 2 4 VGA 4 converting to rackmount 10 cover panels removing 28 cover release latch location 2 D DDR SDRAM see memory device drivers installing 24 DIMM 120 see memory diskette drive connector 7 installing 35 location 2 replacing 35 troubleshooting 88 display troubleshooting 94 documentation Gateway Web site 8 Server Companion CD 24 drive adapter 36
15. The color is not uniform Make sure that the monitor warms up for at least 30 minutes before making a final judgment about color uniformity Make sure that m The monitor is not positioned too close to another monitor electric fan or fluorescent light m You demagnetize the screen using the monitor s degauss feature For more information on degauss see the monitor s documentation A horizontal line or wire is visible across the monitor screen The monitor may use thin damper wires located approximately 1 3 of the way from the upper and lower screen edges to stabilize the internal aperture grille These wires are most obvious when the monitor displays a white background The aperture grille allows more light to pass through the screen for brighter colors and greater luminescence The damper wire is a critical part of the overall monitor design and does not negatively affect the monitor s function Troubleshooting Power You press the power button but the server does not turn on m Ifthe power button LED is green the server is turned on but you may not be seeing an image on the monitor For monitor troubleshooting see Monitor on page 94 m If your server is plugged into a surge protector or UPS make sure that the surge protector or UPS is connected securely to an electrical outlet turned on and working correctly One way to check this is to plug the server directly into a wall outlet bypassing the surge protector or UPS
16. You may lose data if you do not follow the correct procedure gt To turn off the server 1 See the operating system s documentation or online help for instructions on shutting down the operating system Whenever possible you should use the operating system s shut down procedure instead of pressing the power button 2 If your server did not turn off automatically press the power button If nothing happens when you press the power button press and hold it for five seconds and the server will turn off Warning The power button on the server does not turn off server AC power To remove AC power from the server you must D unplug both AC power cords from the wall outlet or power source The power cords are considered the disconnect device to the main AC power Warning If you routinely turn off your server daily or weekly do not unplug the server or use the On Off switch on the surge D protector Regularly cutting off all power to your server may cause the CMOS battery to fail prematurely 15 Chapter 2 Setting Up Your Server Setting up the operating system 16 If you ordered your server with the operating system already installed by Gateway it is completely installed and the basic settings are already configured See your operating system s documentation for instructions on configuring advanced settings for your specific network If you are installing an operating system because it was not already installed by Gatewa
17. consent in writing from Gateway The information in this manual has been carefully checked and is believed to be accurate However changes are made periodically These changes are incorporated in newer publication editions Gateway may improve and or change products described in this publication at any time Due to continuing system improvements Gateway is not responsible for inaccurate information which may appear in this manual For the latest product updates consult the Gateway Web site at www gateway com In no event will Gateway be liable for direct indirect special exemplary incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages In the interest of continued product development Gateway reserves the right to make improvements in this manual and the products it describes at any time without notices or obligation Trademark Acknowledgments 1 800 GATEWAY ActiveCPR ALR AnyKey black and white spot design CrystalScan Destination DestiVu EZ Pad EZ Point Field Mouse Gateway 2000 Gateway Country gateway net Gateway stylized logo Perfect Scholar Solo TelePath Vivitron stylized G design and You ve got a friend in the business slogan are registered trademarks and black and white spotted box logo GATEWAY Gateway Astro Gateway Work Gateway Connected touch pad Gateway Connected music player Gateway Cyber Ware Gateway Education Ware
18. dialing properties are set correctly 92 Troubleshooting gt To check the dialing properties in Windows 2000 Server 1 Click Start Settings then click Control Panel The Control Panel window opens 2 Double click the Modems icon then click Dialing Properties The Dialing Properties dialog box opens 3 Make sure that all settings are correct m Make sure that you are not using a digital rollover or PBX line These lines do not work with your modem m Check for line noise scratchy crackling or popping sounds Line noise is a common problem that can cause the modem to connect at a slower rate abort downloads or even disconnect The faster the modem the less line noise it can tolerate and still work correctly Listen to the line using your telephone Dial a single number such as 1 When the dial tone stops listen for line noise Wiggle the modem cable to see if that makes a difference Make sure that the connectors are free from corrosion and all screws in the wall or telephone jack are secure You can also call your telephone service and have your telephone line checked for noise or low line levels m Try connecting with the modem at a lower connection speed If reducing the connection speed lets you connect contact your telephone service The telephone line may be too noisy m Try another telephone line either a different telephone number in your business or a telephone line at a different location If you ca
19. has two additional 5 25 inch drive bays Your server can have up to eight SCSI hard drives in the hot swap bay behind the front access door CD drive Diskette drive 5 25 inch drive bay 5 25 inch drive bay Hot swap bays As you prepare to install drives remember m Do not use the top 5 25 inch drive bay for drives which have electronic components exposed on the top Drive mounting rails at the top of the bay may damage any exposed electronic components m Before you install a drive see the drive s documentation for information on configuring the drive setting drive jumpers and attaching cables m IDE hard drives can be configured as single master slave or cable select IDE CD drives can be configured as master slave or cable select 34 www gateway com Installing drives m If cable select is available drive assignments will be marked on the cable the IDE cable assigns the master slave positions to the drives it connects You can override these assignments using the jumpers on the drives m Ifcable select is not available and only one drive is attached to an IDE controller cable configure the drive as master if it is a CD drive If two drives of any type are attached to the cable configure one as master and one as slave m You may need to configure the drives you install using the BIOS Setup utility Press F2 at startup to open the BIOS Setup utility Installing an IDE drive Use these instructions
20. holes in the side of the drive tray then secure the drive to the tray with the four screws you removed in Step 4 6 Make sure that the tray s release lever is open then slide the new drive into the empty hot swap bay T Close the drive s release lever 44 www gateway com Installing memory Installing memory When you upgrade your server memory make sure that you install the correct type of memory module for your server Your server uses PC2100 DDR SDRAM registered ECC DIMM memory The following illustration shows the location of the memory modules on the system board Warning Modules must be installed in identical pairs Use only PC2100 DDR SDRAM registered ECC DIMM memory D modules Install memory first into slots 1 and 2 then into slots 3 and 4 If you have memory installed incorrectly your server will not start up i p B DIMM slot 1 Sm DIMM slot 2 e DIMMsiot3 DIMM slot 4 45 Chapter 4 Installing Components gt To install or replace memory 1 2 46 Follow the instructions in Preventing static electricity discharge on page 27 Follow the instructions in Opening the server case on page 28 Pull the plastic tabs away from the sides of the memory module slot If you are replacing a memory module remove the old module Align the notch on the new module with the notch in the memory module slot and press the module firmly into the slot The tabs on the sides of the
21. memory slot should secure the memory module automatically Follow the instructions in Closing the server case on page 32 Turn on the server Make sure that the server turns on and that the operating system loads completely Restart your server and open the BIOS Setup utility Verify the System Memory listed in the Main menu www gateway com Installing PCI expansion cards Installing PCI expansion cards Your server uses the PCI X bus Use the following chart to determine the PCI slot you should install your expansion card into PCI slot Description 1 Always runs at 64 bit 66 MHz Supports 32 bit and 64 bit cards 3 3 V or universal 2 3 Paired slots When only one card is installed in a slot of this pair the slot can run at 64 bit 133 MHz When two 64 bit 100 MHz cards are installed in this pair the slot can run at 64 bit 100 MHz When cards of different speeds are installed in this pair each slot runs at the slowest of the two speeds Supports both 32 bit and 64 bit cards 3 3 V or universal 4 5 Same as slots 2 3 6 Always runs at 32 bit 33 MHz Supports 5 V or universal cards agg s sesesssessessssessseesso or Erag PCI slot 1 PCI slots 2 3 PCI slots 4 5 PCI slot 6 www gateway com 47 Chapter 4 Installing Components gt To replace add or reseat a PCI expansion card 1 Follow the instructions in Preventing static electricity discharge on page 27 2 Follow the instruct
22. not attempt to troubleshoot your server problem if D Power cords or plugs are damaged Liquid has been spilled into your server Your server was dropped The case was damaged Instead unplug your server and contact a qualified computer technician If your server was damaged during shipment from Gateway contact Gateway Technical Support Error messages Error messages These messages often indicate procedural errors such as typing an incorrect keystroke or trying to save a file to a write protected diskette Some messages however may indicate a problem that requires further troubleshooting Diskette drive 0 seek to track 0 failed W Restart your server then open the BIOS Setup utility by pressing and holding F2 while your server restarts Make sure that the drive settings are correct Error loading operating system m The master boot record may be corrupt For troubleshooting information see The master boot record is corrupted on page 91 Hard disk controller failure m Make sure that the hard drive cable is connected securely m Restart your server then open the BIOS Setup utility by pressing and holding F2 while your server restarts Make sure that the correct drive type is selected Hard disk controller failure press F1 to try reboot m The drive controller may be defective Press F1 to try to restart the server For more information about running diagnostics on your hard drive see your operating system s documen
23. or server damage Protect your server and peripheral devices by connecting them to a surge protector which absorbs voltage surges and prevents them from reaching your server Warning High voltages can enter your server through both the power cords and the modem and network connections D Protect your server by using a surge protector If you have a modem use a surge protector that has the appropriate type of modem jack During an electrical storm unplug both the surge protector and the modem and network cables When your purchase a surge protector m Make sure that the surge protector meets the appropriate product safety certification for your location such as Underwriters Laboratories UL m Check the maximum amount of voltage the protector allows to pass through the line The lower the voltage that the protector allows to pass through the better the protection for your server m Check the energy absorption dissipation rating The higher the energy absorption rating the better the protection for your server m Check for line conditioner capabilities A line conditioner smooths out some of the normal line noise small voltage fluctuations of an electrical supply 11 Chapter 2 Setting Up Your Server 12 Line conditioners A line conditioner protects your server from the small fluctuations in voltage from an electrical supply Most servers can handle this variation called line noise without problems However so
24. processor type visit Gateway s eSupport page at support gateway com The eSupport page also has links to additional Gateway documentation and detailed specifications for your own server 106 BIOS Settings You can print this appendix then record your custom BIOS settings on the printout Only settings which can be changed are listed in this appendix For a complete list of viewable BIOS settings run the BIOS Setup utility gt To view all BIOS settings 1 Restart your server 2 Press F2 when the Gateway logo screen appears during startup The BIOS Setup utility opens 3 Select menus and submenus to display setting information n 107 Appendix B BIOS menu BIOS submenu Main Advanced SuperlO Configuration IDE Configuration IDE Configuration Primary IDE Master IDE Configuration Primary IDE Slave 108 Setting Value System Time System Date Plug amp Play O S Reset Config Data OnBoard Floppy Controller Serial Port1 Address Parallel Port Address Parallel Port Mode ECP Mode DMA Channel Parallel Port Irq OnBoard PCI IDE Controller Type LBA Large Mode Block Multi Sector Transfer PIO Mode DMA Mode S M A R T 32Bit Data Transfer ARMD Emulation Type Type LBA Large Mode Block Multi Sector Transfer PIO Mode DMA Mode BIOS menu BIOS submenu IDE Configuration Secondary IDE Master IDE Configuration Secondary IDE Slave IDE Configuration
25. some protection against voltage surges and buildup of static charges Care during use Do not walk on the power cord or allow anything to rest on it Do not spill anything on the system The best way to avoid spills is to avoid eating and drinking near your system Some products have a replaceable CMOS battery on the system board There is a danger of explosion if the CMOS battery is replaced incorrectly Replace the battery with the same or equivalent type recommended by the manufacturer Dispose of batteries according to the manufacturer s instructions When the computer is turned off a small amount of electrical current still flows through the computer To avoid electrical shock always unplug all power cables and modem cables from the wall outlets before cleaning the system Warning This unit has two power supplies To remove power from D all internal circuitry you must disconnect both power cords Unplug the system from the wall outlet and refer servicing to qualified personnel if The power cord or plug is damaged Liquid has been spilled into the system The system does not operate properly when the operating instructions are followed The system was dropped or the cabinet is damaged he system performance changes Replacement parts and accessories 112 Use only replacement parts and accessories recommended by Gateway Important Do not use Gateway products in areas classified as hazardous locations Such ar
26. system Retain all safety and operating instructions for future use Do not use this product near water or a heat source such as a radiator Set up the system on a stable work surface 111 Appendix C The product should be operated only from the type of power source indicated on the rating label If your computer has a voltage selector switch make sure that the switch is in the proper position for your area The voltage selector switch is set at the factory to the correct voltage Openings in the computer case are provided for ventilation Do not block or cover these openings Make sure you provide adequate space at least 6 inches 15 cm around the system for ventilation when you set up your work area Never insert objects of any kind into the computer ventilation openings Some products are equipped with a three wire power cord to make sure that the product is properly grounded when in use The plug on this cord will fit only into a grounding type outlet This is a safety feature If you are unable to insert the plug into an outlet contact an electrician to install the appropriate outlet If you use an extension cord with this system make sure that the total ampere rating on the products plugged into the extension cord does not exceed the extension cord ampere rating If your system is fitted with a TV Tuner cable or satellite receiver card make sure that the antenna or cable system is electrically grounded to provide
27. the bags provide electrostatic protection Always hold expansion cards by their edges or their metal mounting brackets Avoid touching the edge connectors and components on the cards Never slide expansion cards or components over any surface 27 Chapter 4 Installing Components Opening the server case Because the components inside your server are extremely sensitive to static electricity make sure that you follow the instructions at the beginning of this chapter to avoid static electricity damage Warning For correct cooling and air flow always reinstall the side panel and the air duct if included before you turn on the D server Operating the server without the cover in place can damage server components P To open the server case 1 Follow the instructions in Preventing static electricity discharge on page 27 2 Turn off the server then unplug the power cords and all other cables connected to the server Warning This server has two power cords To disconnect internal D AC power you must unplug both power cords 28 Opening the server case 3 Unlock the front cover Release latch E j Release latch Lock 4 Press the two front cover release latches then pull the cover away from the server 5 For more stability place the server on its side www gateway com 29 Chapter 4 Installing Components 6 Loosen the three captive thumbscrews that secure the side panel to the server Thumbscrews
28. using the CD are provided in Using Your Server Companion CD 24 Installing Components Read this chapter to learn how to Open and close the server case Install drives Install expansion cards and memory modules Install processors and replace voltage regulators Check and replace the power supplies Replace the SCSI backplanes Replace the system board Replace case fans Replace the CMOS battery You must open your server case to install components If you are not comfortable with these procedures get help from a more experienced computer user or computer service technician or contact Gateway Technical Support 25 Chapter 4 Installing Components Preparing to install components Selecting a place to work Work on your server in an area that Is clean avoid dusty areas Is a low static environment avoid carpeted areas Has a stable surface on which to set your server Has enough room to place all of your server parts Is near a grounded outlet so you can test your server after installation Is near a telephone in case you need help from Gateway Technical Support The telephone must be directly connected to a telephone jack and cannot be connected to your server Gathering the tools you need Some tools and supplies that you may need to work on your server are 26 A notebook to take notes A Phillips screwdriver A small flat blade screwdriver Small containers to store various types of screws A groundi
29. your BIOS configuration after you have your server set up and working B To record your BIOS configuration 1 Print the appendix for BIOS Settings in this guide 2 Restart your server then press F2 when the Gateway logo screen appears during startup The BIOS Setup utility opens 3 Record the BIOS settings on your printout 21 Chapter 3 Maintaining Your Server System administration Gateway Server Manager Gateway Server Manager lets you manage multiple computers on a Windows network from a single window then implement commands and policies across the network with a single action With Gateway Server Manager you can run system management tasks which are triggered by certain events or conditions Printed documentation comes with the Gateway Server Manager CD You can find additional documentation in the program s online help Server security To prevent unauthorized use of the server you can set BIOS startup passwords Using BIOS security passwords Set up a supervisor password to prevent unauthorized access to the BIOS Setup utility After you create a supervisor password you can set up a user password to prevent unauthorized access to the server You can m Enter either password to finish starting the server W Enter the supervisor password to access the BIOS Setup utility For information about resetting BIOS passwords see Resetting BIOS passwords on page 79 gt To set the BIOS security passwords 1 R
30. 10 C per hour Nonoperating 55 to 150 F 48 3 to 65 5 C Operating 41 to 95 F 5 to 35 C derated 0 9 F 0 5 C for every 1 000 feet 305 meters 10 000 feet 3 048 meters maximum Operating wet bulb Not to exceed 91 4 F 33 C with diskette drive or hard drive Nonoperating 9596 relative noncondensing at 86 F 30 C Operating 2 0 g 11 msec sine Packaged Operational after 30 inch free fall cosmetic damage might occur 100 240 V 8 0 A 50 60 Hz Video specifications Video specifications m DDC 2B support m Integrated 230 MHz DAC m 4 MB memory Resolution support Refresh Rate Hz Resolution 43 60 66 70 72 75 76 85 90 100 640 x 480 x x x x x 800 x 600 x x x x x 1024 x 768 x x x x x 1280 x 1024 x x x x 1600 x 1200 x x x x 103 Appendix A Electronic specifications Memory map Address Range hex Amount Function 0 to O7FFFFh 640 KB DOS region base system memory 0A0000h to OBFFFFh 128 KB Video or SMM memory 0CO0000h and ODFFFFh 128 KB Expansion card BIOS and buffer area OE0000h to OFFFFFh 128 KB System BIOS OEO0000h to OEFFFFh 2 MB Extended system BIOS FCO000000h to FFFFFFFFh 64 MB PCI memory space Interrupts The following table reflects a typical configuration but you can change these interrupts Use this information to determine how to program each interrupt The actual interrupt map is defined using configuration registers in the I O controller I O Redirection
31. 92 91 Chapter 6 Troubleshooting Keyboard Liquid has been spilled into the keyboard m If you spilled liquid in the keyboard turn off your server and unplug the keyboard Clean the keyboard and turn it upside down to drain it Let the keyboard dry before using it again If the keyboard does not work after it dries you may need to replace it This type of damage is not covered by your server s warranty Memory Memory errors were detected during server start up m Open your server and make sure that the memory modules are installed correctly For more information see Installing memory on page 45 m A memory module may be defective If possible try another memory module and see if the error repeats Modem telephone dial up See also Internet Your modem does not dial or does not connect m Make sure that your server is connected to the telephone line and the telephone line has a dial tone m Make sure that the modem cable is less than 6 feet 1 8 meters long m Remove any line splitters or surge protectors from your telephone line then check for a dial tone by plugging a working telephone into the telephone jack m If you have additional telephone services such as call waiting call messaging or voice mail make sure that all messages are cleared and call waiting is disabled before using the modem Contact your telephone service to get the correct code to temporarily disable the service Also make sure that the modem
32. D processor 14 Follow the instructions in Closing the server case on page 32 www gateway com 55 Chapter 4 Installing Components Installing a voltage regulator gt To install a voltage regulator 56 1 2 Follow the instructions in Preventing static electricity discharge on page 27 Follow the instructions in Opening the server case on page 28 If you are installing a new voltage regulator go to Step 5 OR If you are replacing a voltage regulator on each end of the voltage regulator support bracket pinch the sides together then lift the bracket away from the server You may need to first remove a heat sink or some memory modules in order to access the sides of the support bracket Lift the voltage regulator away from the system board Insert the new voltage regulator into the voltage regulator slot then replace the support bracket If you removed a heat sink or some memory modules in Step 3 replace them Follow the instructions in Closing the server case on page 32 www gateway com Replacing the power supply Replacing the power supply Your server uses hot swappable redundant power supplies If one of the two power supplies fails the other power supply supports the server while you replace the failed power supply You do not need to turn off the server or disconnect peripheral devices to replace a failed power supply Warning The power supplies in this server contains n
33. Floppy Configuration OnBoard Devices Configuration Setting Value S M A R T 32Bit Data Transfer ARMD Emulation Type Type LBA Large Mode Block Multi Sector Transfer PIO Mode DMA Mode S M A R T 32Bit Data Transfer ARMD Emulation Type Type LBA Large Mode Block Multi Sector Transfer PIO Mode DMA Mode S M A R T 32Bit Data Transfer ARMD Emulation Type Floppy A OnBoard LAN Device Onboard SCSI Controller 109 Appendix B BIOS menu BIOS submenu Remote Access Configuration Power Boot Boot Device Priority Removable Devices Security 110 Setting Value OnBoard VGA Device Legacy USB Support Remote Access Power Button Mode AC Power Failure Standby Time Out Quiet Boot Wait for F1 If Error 1st Boot Device 2nd Boot Device 1st Removable Device Supervisor Password User Password Safety Regulatory and Legal Information Important safety information Your Gateway system is designed and tested to meet the latest standards for safety of information technology equipment However to ensure safe use of this product it is important that the safety instructions marked on the product and in the documentation are followed Warning Always follow these instructions to help guard against personal injury and damage to D your Gateway system Setting up your system Read and follow all instructions marked on the product and in the documentation before you operate your
34. Gateway Companies Inc 610 Gateway Drive North Sioux City SD 57049 605 232 2000 Fax 605 232 2023 Product Gateway 980 Server For unique identification of the product configuration please submit the 10 digit serial number found on the product to the responsible party This device complies with Part 15 of the FCC Rules Operation of this product is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Caution Changes or modifications not expressly approved by Gateway could void the FCC compliance and negate your AN authority to operate the product 115 Appendix C Canada Industry Canada IC Unintentional emitter per ICES 003 This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of Industry Canada Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de Classe A prescrites dans le r glement sur le brouillage radio lectrique dict par Industrie Canada Telecommunications per DOC notice for products fitted with an IC compliant modem 116 The Industry Canada label identifies certified equipment This certification means that the equipment meets certain telecommunications ne
35. Registers in the I O APIC are provided for each interrupt signal The signals define hardware interrupt signal characteristics for 104 APIC messages sent Important to local APIC s If you disable an IDE controller to free the interrupt for that controller you must physically unplug the IDE cable from the system board Simply disabling the drive by configuring the SSU option does not make the interrupt available Interrupt IRQ Description 0 A OO Im 8254 timer Keyboard controller Cascade Serial port Serial port Interrupt IRQ oO o N Oo A 15 Description USB Diskette controller Parallel Real time clock ACPI SCI Mouse controller System interrupt FERR Primary IDE Secondary IDE PCI interrupt routing PCI interrupt routing in PIC mode Device Rage XL Debug slot Intel 82544GC SCSI 7899W PCI slot 1 PCI slot 2 PCI slot 3 PCI slot 4 PCI slot 5 Interrupt A ICH3 P IRQB ICH3 P IRQE P1 IRQ O 1 IRQ O S1 IRQ 4 82 IRQ 4 PCI IRQ 0 P2 IRQ 4 P2 IRQ 0 Interrupt B ICH3 P IRQF S1 IRQ 1 1 IRQ 5 S2 IRQ 5 PCI IRQ 1 P2 IRQ 5 P2 IRQ 1 Interrupt C ICH3 P IRQG S1 IRQ 2 S2 IRQ 6 PCI IRQ 2 P2 IRQ 6 P2 IRQ 2 Electronic specifications Interrupt D ICH3 P IRQH S1 IRQ 3 S2 IRQ 7 PCI IRQ 3 P2 IRQ 7 P2 IRQ 3 105 Appendix A Additional specifications For more information about your server such as memory size hard drive size and
36. ach you how to use the Internet and the most popular software programs including Microsoft Word Excel and PowerPoint A variety of courses and tutorials are available on CD Select from several easy to use learning libraries More than 450 online courses are available from Learn Q Gateway All you have to do is go online and log in You select the subject matter and the learning format self paced tutorials or virtual classrooms all from the comfort of your computer For more information www gateway com country www gateway com training www learnatgateway com Server Specifications The following specifications are for the standard configuration Your server may contain optional equipment All specifications are subject to change 99 Appendix A System specifications 100 Case size Weight Fans Ports Drives standard Card sizes Power supply Operating systems Certifications Tower 7 75 x 18 x 17 5 inches 19 69 x 45 72 x 44 45 cm Varies by configuration 3 chassis fans speed adjustable PS 2 keyboard PS 2 mouse USB 4 Serial VGA Parallel RJ 45 LAN 3 5 inch diskette CD ROM Supports full length full height PCI expansion cards 450 W RPS 2 Supports Windows 2000 Server Compatible with Windows NT Novell NetWare 6 FCC Class A UL cUL System board specifications System board specifications Processor Chipset Me
37. bles are connected to the drive For more information see Installing PCI expansion cards on page 47 or your controller card s documentation Make sure that the power cable and SCSI cable are attached securely to the drive Make sure that the last device on the SCSI cable is correctly terminated For more information about SCSI device configurations see the device s documentation Use a different SCSI cable Troubleshooting The master boot record is corrupted m ina Windows network operating system repair the master boot record using FDISK B To repair the master boot record m Ata DOS command prompt type fdisk mbr then press ENTER You need to troubleshoot an IDE hard drive m Use the GWScan utility to test a hard drive s ability to read data and to measure seek times and transfer rates GWScan can also repair some errors that may develop on IDE hard drives B To download the GWScan utility m Search for the utility at support gateway com For information about how to use GWScan go to ftp ftp gateway com pub hardware support drivers win3 x and dos mass storage hard drives 7510801 txt Internet See also Modem You cannot connect to the Internet m Make sure that your account with your Internet Service Provider ISP is set up correctly Contact your ISP technical support for help m Make sure that you do not have a problem with your modem For more information see Modem telephone dial up on page
38. ce description Order a catalog of documents on common problems then order documents by document numbers The documents will be faxed to you Learn networking tips from Gateway s tutorial support on a per issue fee basis Talkto a Gateway Technical Support representative about a non tutorial technical support question See Before calling Gateway Technical Support on page 96 before calling TDD Technical Support for hearing impaired is available Weekdays 6 00 a m 8 00 p m Central Time Weekends 6 00 a m 5 00 p m Central Time Get information about available systems pricing orders billing statements warranty service or other non technical issues Telephone support How to reach 800 846 4526 US 877 709 2951 Canada 877 485 1464 US 800 846 3609 Canada and Puerto Rico 605 232 2191 all other countries 800 846 1778 TDD 877 485 1464 US 800 846 3609 Canada and Puerto Rico 605 232 2191 all other countries 800 846 1778 TDD 800 846 2000 US 888 888 2037 Canada 97 Chapter 6 Troubleshooting Tutoring and training Gateway s Technical Support professionals cannot provide hardware and software training Instead Gateway recommends the following training resources Resource In store training at Gateway stores Gateway Learning Libraries Online training from Learn Gateway 98 Service description Our friendly and knowledgeable software trainers can te
39. d corresponds with Pin 1 on the diskette drive typically on the side farthest from the power supply connection If necessary reverse one end of the cable so the red striped edge of the data ribbon cable faces Pin 1 on the diskette drive Make sure that the pins are not bent or misaligned For more information see Installing an IDE drive on page 35 Expansion cards Your server does not recognize an expansion card m Restart your server m Makesurethat you have installed the necessary software or driver For more information see the card s documentation m Reseatthe card For more information see Installing PCI expansion cards on page 47 m Install the card in a different slot Hard drive The hard drive cannot be accessed or you receive a General failure reading drive C error message m If a diskette is in the diskette drive eject it and restart your server by pressing the reset button Restart your server by pressing the reset button m Use GWScan to test the hard drive For more information see You need to troubleshoot an IDE hard drive on page 91 W Open your server and make sure that the cables are connected correctly to the hard drive and the system board For more information see Installing a SCSI hard drive on page 42 m If your server has been subjected to static electricity or physical shock you may need to reinstall the operating system 89 Chapter 6 Troubleshooting 90 You receive a N
40. de of the hot swap bay identify the SCSI ID of each drive Install the topmost drives first Gateway tests and verifies the operation and compatibility of the drives it sells Especially in a hot swap or mission critical environment additional or replacement drives must conform to Gateway standards gt To install a hard drive 1 Unlock the front cover s lock then swing the hot swap bay door open Hot swap bays 42 www gateway com Installing drives 2 Ifa drive has failed determine which drive has failed by running storage console software Match the software s SCSI ID for the failed drive with the SCSI ID number to the left of the hot swap bays 3 Pull the drive tray s lever away from the server then pull the tray straight out of the server Caution Before you remove a failed drive use the appropriate software and utilities installed on the server to stop all N activity on the failed drive Instructions for using the software are provided by the software manufacturer Failure to do so may destroy the data on the drive 4 1f you are replacing a hard drive remove the four screws that secure the hard drive to the drive tray then remove the drive from the tray Screw OR www gateway com 43 Chapter 4 Installing Components If you are adding a new drive remove the bag taped to the inside of the drive tray then remove the screws from the bag 5 Line up the screw holes in the new drive with the
41. drive bays location 2 drivers installing 24 drives CD 2 35 configuring 34 diskette 2 35 hard drive 42 hot swap 3 42 installing 34 installing 5 25 inch 35 installing CD 35 installing diskette 35 installing hard drive 42 installing hot swap 42 installing RAID 42 installing SCSI 42 RAID 3 42 replacing 34 SCSI 3 42 tape 20 troubleshooting 88 89 E electronic specifications 104 electrostatic discharge ESD 27 environmental specifications 102 error messages 83 eSupport 106 Exit menu BIOS Setup utility 76 expansion card see card F fans connectors 7 hot swap bay 5 7 installing 69 location 4 5 7 PCI card 5 7 rear 4 5 finding specifications 99 106 front panel connector 7 G Gateway 8 Learn Gateway 98 Learning Libraries 98 stores 98 Technical Support 96 Web address 8 Gateway Server Manager 22 H hard drive indicator 2 installing 42 LED indicator 2 troubleshooting 89 heat sink installing 52 help telephone support 96 tutoring 98 hot swap cage 60 hard drives 3 42 power supply 57 hot swap drives fan 5 7 installing 42 location 2 l IDE BIOS configuration 108 cables 34 connectors 7 drive configuration 34 indicators 2 13 installing 5 25 inch drive 35 add in card 47 backplane 60 battery 71 card 47 CD drive 35 diskette drive 35 expansion cards 47 fans 69 hard drive 42 heat sink 52 hot swap cage 60 hot swap drive 42 media drive 35 memory 45 PCI card 47 power supply 57
42. eas include patient care areas of medical and dental facilities oxygen laden environments or industrial facilities Warning To reduce the risk of fire use only No 26 AWG or larger D telecommunications line cord 113 Appendix C Regulatory compliance statements Uni ted States of America Federal Communications Commission FCC Unintentional emitter per FCC Part 15 FCC Part 15 Class A Statement The server is designated as complying with Class A requirements if it bares the following text on the rating label This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a commercial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required to correct the interference at your own expense Caution Changes or modifications
43. ecting from surges 11 reset button 2 source problems 11 static electricity 27 surge protectors 11 troubleshooting 95 uninterruptible power supply UPS 12 Power menu BIOS Setup utility 76 110 power supply installing 57 manageability connector 7 uninterruptible 12 power on self test 14 processor fan connector 7 heat sink 52 installing 52 location 6 replacing 52 troubleshooting 95 R rackmount 10 RAID cage 60 RAID drives installing 42 location 3 RAM see memory rear fan 4 5 recovering BIOS 77 removing see installing replacing see installing reset button 2 resolution video 103 resources interrupts 104 memory map 104 RJ 45 jack 4 S safety general precautions 10 111 guidelines for troubleshooting 82 static electricity 27 screen cleaning 19 troubleshooting 94 SCSI backplane 60 connector 7 determining failed 43 ID 42 installing drives 42 SDRAM see memory security set passwords 22 setting up in BIOS 22 supervisor password 22 system 22 user passwords 22 using password 22 Security menu BIOS Setup utility 76 110 security switch connector location 7 serial number 96 serial port 4 Server Companion CD 8 24 setting up hardware 10 operating system 16 safety precautions 10 18 111 Setup utility see BIOS Setup utility slots card 6 memory 7 processor 6 123 voltage regulator 7 specifications 99 106 electronic 104 environmental 102 system board 101 video 103 starti
44. ersion For more information see Updating the BIOS on page 77 2 Follow the instructions in Preventing static electricity discharge on page 27 3 Follow the instructions in Opening the server case on page 28 Tips amp Tricks To make removing the heat sinks easier first remove the ON voltage regulators PCI expansion cards and rear fan For more information see Installing a voltage regulator on 4 page 56 Installing PCI expansion cards on page 47 and Replacing a fan on page 69 52 Installing a processor 4 if your server has a passive heat sink press down on the heat sink locking lever on each side push them slightly away from the heat sink then lift the levers out of the way OR If your server has a heat sink with a fan press down on the heat sink locking lever on each side push them slightly away from the heat sink then lift the levers out of the way Unplug the heat sink s fan from its connector on the system board www gateway com 53 Chapter 4 Installing Components 5 Remove the heat sink Important The heat sink mounting paste may harden over time and hold the heat sink securely to the processor If removing the heat sink also pulls the processor out of the processor Socket the processor should still be undamaged Rotate the processor locking lever out of the way and continue with the procedure 6 Press down on the processor locking lever push it slightly away from the proces
45. ery with an equivalent battery Warning Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type D recommended by the manufacturer Dispose of used batteries following the manufacturer s instructions B To replace the battery 1 Print the appendix for BIOS Settings in this guide 2 Open the BIOS Setup utility by following the instructions in Opening the BIOS Setup utility on page 76 3 Record the BIOS settings on your printout then close the utility 4 Turn off your server then follow the instructions in Preventing static electricity discharge on page 27 5 Follow the instructions in Opening the server case on page 28 71 Chapter 4 Installing Components 6 Locate the old battery on the system board and note its orientation You will need to install the new battery the same way Tu 1 72 www gateway com Replacing the CMOS battery 7 Push the battery retention clip away from the battery until the battery lifts up You can use a screwdriver to help lift the battery 8 Remove the old battery 9 Make sure that the positive side of the new battery is facing up then press the new battery into the socket until it snaps into place 10 Follow the instructions in Closing the server case on page 32 11 Turn on the server 12 Press F2 when the Gateway logo screen appears during startup The BIOS Setup utility opens 13 Restore any BIOS settings tha
46. estart your server then press F2 when the Gateway logo screen appears during startup The BIOS Setup utility opens 2 Select the Security menu 22 System administration 3 Select the password to set according to the following table Option Description Supervisor password To control access to system configuration set a supervisor password Using a supervisor password lets you make changes to any setting in the BIOS Passwords can be cleared To clear the passwords see Resetting BIOS passwords on page 79 User password The supervisor password must be set up before a user password can be set To control access to the server set a user password The supervisor can set the level of access granted to the user password The user password access levels are No Access User cannot access the BIOS Setup utility Limited User can change only the date and time View Only User can see all settings but cannot change them Full User can change every setting except the supervisor password Passwords can be cleared To clear the passwords see Resetting BIOS passwords on page 79 4 Type the password and press ENTER then type it again and press ENTER 5 Save your changes and exit the BIOS Setup utility 23 Chapter 3 Maintaining Your Server Using your Server Companion CD You can use your Server Companion CD to m Install hardware drivers m Install programs W View server documentation Instructions for
47. et do not attempt to modify the plugs in any way Use a surge protector UPS or wall outlet that is appropriate for the supplied AC power cords W Avoid subjecting your server to extreme temperature changes Do not expose your server to direct sunlight heating ducts or other heat generating objects Damage caused by extreme temperatures is not covered by your warranty As a general rule your server is safest at temperatures that are comfortable for you Keep your server and magnetic media away from equipment that generates magnetic fields such as unshielded stereo speakers Strong magnetic fields can erase data on both diskettes and hard drives Even a telephone placed too close to the server may cause interference Important Keep the server boxes and packing material in case you need to send the server to Gateway for service If you return your server in different packaging your warranty may be voided Converting to a rackmount server To convert your server to a rackmount configuration see Installing Your Gateway 960 or 980 Server into a Rackmount Cabinet 10 Protecting from power source problems Protecting from power source problems Surge protectors line conditioners and uninterruptible power supplies can help protect your server against power source problems Surge protectors During a power surge the voltage level of electricity coming into your server can increase to far above normal levels and cause data loss
48. figuration settings If an error occurs in a program see its documentation or online help Warning To avoid bodily injury do not attempt to troubleshoot your server problem if D Power cords or plugs are damaged Liquid has been spilled into your server Your server was dropped The case was damaged Instead unplug your server and contact a qualified computer technician Battery replacement If you have problems after installing a new CMOS battery try each of the following items closing the case and restarting the server after each try Restart your server then open the BIOS Setup utility by pressing and holding F2 while your server restarts Correct any discrepancies 85 Chapter 6 Troubleshooting m Remove the side panel by following the instructions in Closing the server case on page 32 then make sure that all cables inside the case are attached securely Also make sure that the colored cable edges are aligned correctly and that the connectors do not miss any pins Warning To avoid bodily injury do not attempt to troubleshoot your server problem if D Power cords or plugs are damaged Liquid has been spilled into your server Your server was dropped The case was damaged Instead unplug your server and contact a qualified computer technician m If you have the correct test equipment make sure that the new battery has power Although unlikely your new battery may be defective Beep codes 86
49. four SCSI drives Each hot swap cage is connected to a SCSI backplane The pictures in this procedure show replacing the upper SCSI backplane The other backplane can be replaced in the same manner gt To replace the SCSI backplane 1 Follow the instructions in Preventing static electricity discharge on page 27 2 Follow the instructions in Opening the server case on page 28 3 Remove the fan nearest the SCSI backplane For instructions see Replacing a fan on page 69 4 Remove each of the drives from the hot swap cage and note the location of each drive For instructions see Installing a SCSI hard drive on page 42 5 Loosen the four captive thumbscrews on the front of the hot swap cage Thumb screws Thumb screws 60 www gateway com Replacing the SCSI backplane 6 Slide the hot swap cage out about two inches from the case www gateway com 61 Chapter 4 Installing Components 7 From inside the case remove the power SCSI and manageability cables from the backplane The manageability cable connector is visible after removing the SCSI and power cables 8 Remove the hot swap cage completely from the server 62 www gateway com Replacing the SCSI backplane 9 Loosen the captive thumbscrew that secures the backplane to the hot swap cage Thumbscrew P N FDASS2TB28C4 REV C www gateway com 63 Chapter 4 Installing Components 10 Slide the backplane up slightly then lift it a
50. gateway com 13 Chapter 2 Setting Up Your Server If nothing happens when you press the power button m Make sure that the power cords are plugged in securely and that your surge protector if you are using one is plugged in and turned on m Make sure that the monitor is connected to the server plugged into the power outlet or surge protector and turned on You may also need to adjust the monitor s brightness and contrast controls 2 The first time you turn on the server any pre installed operating system may begin asking you for configuration settings See your operating system s documentation for instructions on configuring advanced settings for your specific network gt To select which device your server boots from 1 During server startup press F10 The Boot menu opens 2 Select the device you want to boot from Common choices include Removable Dev Removable device ATAPI CDROM CD drive Hard Drive IBA GE NIC Network boot Understanding the power on self test When you turn on your server the power on self test POST routine checks the server memory and components If POST finds any problems the server displays error messages Write down any error messages that you see then see Error messages on page 83 and Beep codes on page 86 for troubleshooting information 14 Turning off your server Turning off your server Every time you turn off your server first shut down the operating system
51. ions in Opening the server case on page 28 3 If you are replacing a card disconnect any cables that are attached to the old card 4 If you are removing a full length card pull back on the card retention clip that secures the end of the card OR If you are adding a full length card to an empty expansion slot pull back on the card retention clip for that slot 48 www gateway com Installing PCI expansion cards 5 Pull the card retention cover s release lever then swing the retention cover away from the expansion cards Release lever Card retention cover 6 Ifyou are replacing a card remove the old expansion card You can slightly seesaw the card end to end to loosen the card but do not bend the card sideways Warning Do not touch the contacts on the bottom part of the expansion card Touching the contacts can cause D electrostatic damage to the card 7 Press the new card into the expansion slot You can slightly seesaw the card end to end to help insert the card but do not bend the card sideways g E j www gateway com 49 Chapter 4 Installing Components 8 Push the card retention cover against the expansion cards until the retention cover clicks into place under the release lever Release lever Card retention cover OR Press on the card retention cover lever on the back of the server until the lever is flush with the back of the case 9 If you are installing a full leng
52. lty This is not a fatal error The ROM checksum value does not match the value encoded in the BIOS The shutdown register for CMOS RAM failed The external cache is faulty Troubleshooting Troubleshooting steps Reseat the memory or replace with modules you know are good Same as for 1 beep Same as for 1 beep Remove all expansion cards f the beep code occurs even when all expansion cards have been removed the system board is at fault If the beep code does not occur when the expansion cards have been removed one of the cards is causing the problem Install the cards one at a time until the problem happens again When the beep code returns the most recent card you installed is at fault Same as for 4 beeps Same as for 4 beeps Same as for 4 beeps The system board may be faulty Same as for 4 beeps Same as for 4 beeps Same as for 4 beeps The settings in the BIOS Setup utility are not retained m Replace the CMOS battery For more information see Replacing the CMOS battery on page 71 87 Chapter 6 Troubleshooting CD drive Your server does not recognize a CD or the CD drive W Restart your server then open the BIOS Setup utility by pressing and holding F2 while your server restarts Make sure that the IDE controllers are enabled For more information see Using the BIOS Setup Utility on page 75 Reinstall the device driver For more information see Using Your Server Com
53. lved The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of this equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service This equipment cannot be used on telephone company provided coin service Connection to party line service is subject to state tariffs Contact the state public utility commission or public service commission for information When programming or making test calls to emergency numbers Remain on the line and briefly explain to the dispatcher the reason for the call Perform such activities in the off peak hours such as early morning or late evenings The United States Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device to send any message via a telephone fax machine unless such message clearly contains in a margin at the top or bottom of each transmitted page or on the first page of the transmission the date and time it is sent an identification of the business other entity or other individual sending the message and the telephone number of the sending machine or such business other entity or individual Refer to your fax communication software documentation for details on how to comply with the fax branding requirement FCC declaration of conformity Responsible party
54. me electrical sources include more line noise than normal Line noise can also be a problem if your server is located near or shares a circuit with a device that causes electromagnetic interference such as a television or a motor Some surge protectors and uninterruptible power supplies include simple line conditioning capabilities Uninterruptible power supplies Usean uninterruptible power supply UPS to protect your server from data loss during a total power failure A UPS uses a battery to keep your server running temporarily during a power failure and lets you save your work and shut down your server You cannot run your server for an extended period of time while using only the UPS To buy a UPS visit accessories gateway com Starting your server Starting your server Before you start your server for the first time m Make sure that the server and monitor are plugged into a power outlet or surge protector and that the surge protector if you are using one is turned on m Make sure that all cables are connected securely to the correct ports and jacks on the back of the server Warning When you connect peripheral devices to the server make sure that your server and devices are turned off and the D power cords are unplugged gt To start the server 1 Press the power button Power button When the power It means indicator is Green The server is turned on Off The server is turned off www
55. mory PCI device slot VGA LAN RAID ACPI Hardware Monitor Dual 603 pin E7500 or 604 pin E7501 sockets 400 MHz E7500 or 400 MHz 533 MHz E7501 system bus Supports Intel Xeon CPU with 512 KB cache 1 VRM per processor 9 1 compliant Intel E7500 or E7501 400 MHz E7500 or 400 533 MHz E7501 system bus Dual PC1600 E7500 or PC2100 E7501 DDR SDRAM memory channels with ECC ATA 100 IDE interface two channels USB 1 1 4 ports Four DIMM slots support up to 8 GB total memory ECC registered DDR SDRAM On board VGA Gb Ethernet and U160 SCSI E7500 or U320 SCSI E7501 PCI slots 32 bit 33 MHz slot 1 64 bit 66 MHz slot 1 64 bit 100 MHz slot 4 or 64 bit 133 MHz slot 2 On board ATI Rage XL 4 MB SDRAM E7500 8 MB SDRAM E7501 On board Intel 82544GC Gb Ethernet NIC 64 bit 133 MHz PCI X interface 10Base T 100Base TX 1000Base T PXE support LSI Elite 1600 493 ACPI compliance Supports SO S1 S4 S5 Main logic board sensors Voltage sensors Temperature sensors Adaptive fan speed control and fan speed detection 101 Appendix A Environmental specifications 102 The following specifications identify maximum environmental conditions At no time should the server run under conditions which violate these specifications Variable Temperature Altitude Humidity Shock AC input power Requirements Maximum rate of change 18 F
56. n connect on this line call your telephone service Your 56K modem does not connect at 56K Current FCC regulations restrict actual data transfer rates over public telephone lines to 53K Other factors such as line noise telephone service provider equipment or ISP limitations may lower the speed even further If your system has a v 90 modem the speed at which you can upload send data is limited to 33 6K If your system has a v 92 modem the speed at which you can upload data is limited to 48K Your ISP may not support 48K uploads 93 Chapter 6 Troubleshooting The modem is not recognized by your server m If the modem shares the telephone line with another device make sure that the telephone line is not in use for example someone is on the telephone or another modem is in use m Shut down and restart your server m Reinstall the modem device driver For more information see Using Your Server Companion CD W Open your server and reseat the modem For more information see Installing PCI expansion cards on page 47 Monitor 94 Your server is running but there is no picture m Adjust the brightness and contrast controls to the center position m Make sure that the monitor is plugged in and turned on If the monitor is turned on the power LED should be lit m Check the port and cable for bent or damaged pins m Connect your monitor to another computer or connect a monitor that you know works to your server
57. ned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5 Laser safety statement All Gateway systems equipped with CD and DVD drives comply with the appropriate safety standards including IEC 825 The laser devices in these components are classified as Class 1 Laser Products under a US Department of Health and Human Services DHHS Radiation Performance Standard Should the unit ever need servicing contact an authorized service location Warning Use of controls or adjustments or performance of procedures other than those specified in this manual may D result in hazardous radiation exposure To prevent exposure to laser beams do not try to open the enclosure of a CD or DVD drive California Proposition 65 Warning Warning This product contains chemicals including lead known to the State of California to cause cancer and or birth defects D or reproductive harm 117 Appendix C Notices Copyright 2003 Gateway Inc All Rights Reserved 14303 Gateway Place Poway CA 92064 USA All Rights Reserved This publication is protected by copyright and all rights are reserved No part of it may be reproduced or transmitted by any means or in any form without prior
58. ng server 13 static electricity 27 supervisor password 22 surge protector 11 system 100 administration 22 control 22 management 22 security 22 specifications 100 startup 13 system board components 6 7 installing 66 replacing 66 specifications 101 thumbscrew location 4 system configuration protecting with passwords 22 system interrupts 104 system recovery recording BIOS configuration 21 I tape drive cleaning 20 technical support FaxBack support 97 resources 96 Technical Support 96 97 tips before contacting 96 telephone support 96 training CD 98 classroom 98 Gateway Learning Libraries 98 Learn Gateway 98 124 troubleshooting add in card 89 battery 85 beep codes 86 BIOS 87 card 89 CD 88 CD drive 88 diskette drive 88 error messages 83 expansion card 89 faxed answers 97 general guidelines 85 general safety guidelines 82 hard drive 89 IDE drive 90 91 Internet connection 91 keyboard 92 master boot record 91 memory 92 modem 92 monitor 94 power 95 power source problems 11 processor 95 safety guidelines 82 SCSI drive 90 technical support 96 telephone support 96 video 94 turning off server 15 turning on server 13 uninterruptible power supply UPS 12 updating BIOS 77 UPS 12 USB ports location 2 4 user password 22 utilities BIOS Setup 75 V VGA port 4 video 103 voltage regulator installing 56 location 7 W Web site Gateway 8 125 126
59. ng wrist strap available at most electronic stores Preventing static electricity discharge Preventing static electricity discharge The components inside your server are extremely sensitive to static electricity also known as electrostatic discharge ESD Warning ESD can permanently damage electrostatic discharge sensitive components in the server Prevent D ESD damage by following ESD guidelines every time you open the server case Warning To avoid exposure to dangerous electrical voltages and moving parts turn off your server and unplug the power D cords and modem cable before opening the server case Before working with server components follow these guidelines Turn off the server then unplug the power cords and all other cables Press the power button to drain any residual power from the server Wear a grounding wrist strap available at most electronics stores and attach it to a bare metal part of the server You can also touch a bare metal surface on the back of the server with your finger Warning To prevent risk of electric shock do not insert any object D into the vent holes of the power supply Avoid static causing surfaces such as carpeted floors plastic and packing foam Avoid working on the server when your work area is extremely humid Remove components from their antistatic bags only when you are ready to use them Do not lay components on the outside of antistatic bags because only the inside of
60. not expressly approved by Gateway could void the FCC compliance and negate your authority to operate the product Telecommunications per FCC part 68 applicable to products fitted with USA modems 114 Your modem complies with Part 68 of the Federal Communications Commission FCC rules On the computer or modem card is a label that contains the FCC registration number and Ringer Equivalence Number REN for this device If requested this information must be provided to the telephone company An FCC compliant telephone line cord with a modular plug is required for use with this device The modem is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant See installation instructions for details The Ringer Equivalence Number REN is used to determine the number of devices which may be connected to the telephone line Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call In most areas the sum of RENs should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as determined by the total RENS contact the local telephone company If this device causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required The telephone company may request that you disconnect the equipment until the problem is reso
61. o user serviceable parts Only a qualified computer D technician should service the power supplies Your server comes with 3 wire AC power cords fitted with the correct plug style for your region If this plug does not match the connector on your surge protector UPS or wall outlet do not attempt to modify the plug in any way Use a surge protector UPS or wall outlet that is appropriate for the supplied AC power cords 57 Chapter 4 Installing Components B To replace the power supply 1 Examine the LED indicators on the back of each power supply to identify the failed power supply The power supply has failed if the center LED indicator is on Server is turned on Fault in power supply center LED Power supply is connected to AC power source 58 www gateway com Replacing the power supply 2 Unplug the power cord from the failed power supply 3 While pressing the power supply s lever release latch pull the lever away from the server 4 Pull the power supply straight out of the server 5 Slide the new power supply into the power supply bay as far as it will go then swing the lever up until it snaps into place 6 Plug the power cord into the new power supply The new power supply is ready if the bottom green LED is on and the top LED is on or blinking www gateway com 59 Chapter 4 Installing Components Replacing the SCSI backplane Your server has two hot swap cages that can each hold
62. of these menus Main gives you access to basic information and settings related to your server s hardware and configuration Advanced gives you access to information and settings for system resources hardware and server s configuration Power gives you access to settings that control your server s power management features Boot gives you access to information and settings for startup features and startup sequences Security gives you access to settings related to system access passwords For more information see Server security on page 22 Exit gives you access to options for closing the BIOS Setup utility Updating the BIOS Updating the BIOS If you need a new version of the BIOS you can download the BIOS update from Gateway then install the new version from a diskette B To update the BIOS 1 Print the appendix for BIOS Settings in this guide 2 Download the BIOS update from support gateway com 3 Restart your server then press F2 when the Gateway logo screen appears during startup 4 Record any custom BIOS settings on your printout ol Follow the instructions in the self extracting BIOS update file 6 Enter any custom BIOS settings you recorded in Step 4 then save your changes and close the BIOS Setup utility n Recovering the BIOS If you encounter a problem while you are updating the BIOS such as a power outage the BIOS update may not be successful You can recover the old BIOS so
63. on system disk or disk error error message Eject the diskette from the diskette drive then press ENTER Make sure that your hard drive has an active partition For more information see The master boot record is corrupted on page 91 Your server does not recognize an IDE drive Make sure that the IDE connectors are enabled in the BIOS Setup utility For more information see Using the BIOS Setup Utility on page 75 Reinstall the device driver For more information see Using Your Server Companion CD Use GWScan to test the hard drive For more information see You need to troubleshoot an IDE hard drive on page 91 Open your server and make sure that the IDE cable is connected to both the system board IDE connector and the hard drive connector For more information see Installing a SCSI hard drive on page 42 Your server does not recognize a SCSI drive Make sure that the SCSI controller is enabled in the BIOS Setup utility Reinstall the device driver For more information see Using Your Server Companion CD Change the drive s SCSI address to one that is not being used by your server For more information about SCSI device configurations see your drive s documentation Run SCSI Verify in the SCSI BIOS For more information about the SCSI BIOS see the SCSI controller s documentation Reseat the drive Open your server and reseat the drive controller card Also make sure that the controller card and power ca
64. panion CD Make sure that the drive is configured correctly by following the instructions in the drive s documentation Open your server case and make sure that the cables are connected correctly to the CD drive and the IDE connector on the system board or controller card Your CD drive tray does not open Press a straightened paper clip wire into the CD drive s manual eject hole The drive tray opens If this problem happens frequently while the server is turned on the drive may be defective Diskette drive The diskette drive is not recognized Restart your server Open your server case and make sure that the cables are connected correctly to the diskette drive and the system board The red striped edge of the data ribbon cable indicates Pin 1 and corresponds with Pin 1 on the diskette drive typically on the side farthest from the power supply connection If necessary reverse one end of the cable so the red striped edge of the data ribbon cable faces Pin 1 on the diskette drive Make sure that the pins are not bent or misaligned For more information see Installing an IDE drive on page 35 The diskette drive LED is lit continuously 88 Remove the diskette from the drive If the light stays on try restarting your server Troubleshooting m Open your server and make sure that the cables are connected correctly to the diskette drive and the system board The red striped edge of the data ribbon cable indicates Pin 1 an
65. processor 52 RAID drive 42 SCSI backplane 60 SCSI drive 42 system board 66 voltage regulator 56 Internet connection troubleshooting 91 interrupts 104 PCI routing 105 intrusion switch 7 intrusion switch connector location 7 IRQ assignments 104 121 J jacks see connections jumper location 7 K Kensington lock slot 4 keyboard cleaning 19 port 4 troubleshooting 92 L LAN jack 4 LED indicators 2 13 line conditioners 12 lock Kensington 4 key 2 29 location 2 4 M Main menu BIOS Setup utility 76 108 maintenance cleaning 18 cleaning case 18 cleaning keyboard 19 cleaning screen 19 Gateway Server Manager 22 general guidelines 18 recording BIOS configuration 21 master boot record 91 memory installing 45 map 104 slot location 7 troubleshooting 92 messages 83 modem connection speed 93 troubleshooting 92 monitor 122 cleaning 19 port 4 troubleshooting 94 motherboard see system board mouse port 4 N network jack 4 non technical support Accounting 97 Sales 97 Warranty 97 O opening case 28 operating system setting up 16 P parallel port 4 password resetting BIOS 79 supervisor 22 user 22 PCI card fan 5 7 slot 6 PCI expansion card see card PCI interrupt routing 105 ports see connections POST power on self test 14 power auxiliary connector 7 BIOS Setup utility 110 button 2 13 15 cord connector 4 7 indicator 2 13 LED 2 13 line conditioners 12 main connector 7 prot
66. r a possible solution Memory size error W Restart your server then open the BIOS Setup utility by pressing and holding F2 while your server restarts Save the memory configuration Missing operating system m The master boot record may be corrupt For troubleshooting information see The master boot record is corrupted on page 91 System Event Log Full W Clear the event log To clear or view the event log restart your server then open the BIOS Setup utility by pressing and holding FZ while your server restarts Select the Advanced menu then select the Event Log Control menu 84 Troubleshooting Troubleshooting First steps Try these steps first before going to the following sections Make sure that the power cords are connected to your server and an AC outlet and that the AC outlet is supplying power If you use a surge protector or a UPS make sure that it is turned on and is rated to handle the power required by your server If you added or removed server components before the problem started review the installation procedures you performed and make sure that you followed each instruction You may need to remove the device uninstall the device s software then reinstall the device If an error message appears on the screen write down the exact message before calling Gateway Technical Support Restart your server then open the BIOS Setup utility by pressing and holding F2 while your server restarts Check your con
67. r old system board by removing the eight screws that secure them to the board Remove the voltage regulators For more information see Installing a voltage regulator on page 56 Disconnect the power data and fan cables from the system board noting their locations and orientation You will reconnect the cables after you install the new board Remove the rear fan to provide more space for removing the system board For more information see Replacing a fan on page 69 Replacing the system board 10 Remove the system board tray s thumbscrew on the back of the case System board tray thumbscrew 11 Slide the tray toward the front of the case If the tray is difficult to move push on the rear port panel for added leverage www gateway com 67 Chapter 4 Installing Components 68 12 13 14 15 16 17 18 19 20 21 Lift the tray away from the case Insert the new system board tray into the case then slide the tray toward the back of the case Tighten the system board tray thumbscrew on the back of the case Reinstall the memory processors voltage regulators and fans Connect the power and data cables Reinstall the expansion cards For more information see Installing PCI expansion cards on page 47 Follow the instructions in Closing the server case on page 32 Turn on your server Press FZ when the Gateway logo screen appears during startup The BIOS Setup utility opens
68. rver Companion CD Use the Server Companion CD to access file utilities Windows 2000 Server drivers and documentation for your server and its components For more information see Using Your Server Companion CD Gateway Web site Gateway provides a variety of information on its Web site to help you use your server Visit the Gateway Web site at support gateway com for Technical documentation and product guides Technical tips and support Updated hardware drivers Order status Frequently asked questions FAQs Setting Up Your Server Read this chapter to learn how to Use your server safely Start and turn off your server Restart reboot your server Set up the operating system Chapter 2 Setting Up Your Server Setting up the hardware To make sure that your working environment is safe Use a clean dry flat stable surface for your server Allow at least 6 inches at the rear of the server for cabling and air circulation Use the instructions on your server s setup poster to set up your hardware Use a grounded three prong surge protector A surge protector helps protect against AC power fluctuations For additional protection from power outages we recommend that you use an uninterruptible power supply UPS Warning Your server comes with a 3 wire AC power cords fitted with the correct plug style for your region If these plugs do not D match the connector on your surge protector UPS or wall outl
69. s 1 Serial port Parallel port Monitor port Rear fan LAN jack T RJ 45 System board thumbscrew Card retention cover lever Kensington lock slot 4 www gateway com Interior i am o 0 1 amm 1 01 o M o mI SCSI backplane Card retention Full length card Cable clip cover release Rear fan retention clip latch Hot swap bay fan PCI card fan www gateway com Interior Chapter 1 Checking Out Your Gateway Server System board Left side Processor 1 Processor 2 Rear fan connector 64 bit PCI card slots 32 bit PCI card slot 6 www gateway com Right side Processor 1 fan connector Front panel connector SCSI manageability connector Processor 2 fan connector Power supply manageability connector 555255022522222 Auxiliary power connector M www gateway com System board Main power connector Voltage regulator slot 1 Memory module slots Voltage regulator slot 2 Diskette drive connector Primary IDE connector Secondary IDE connector Intrusion switch connector SCSI 2 connector SCSI 1 connector Hot swap bay fan connector CMOS battery Configuration jumper JP7 PCI card fan connector Chapter 1 Checking Out Your Gateway Server Getting Help In addition to your operating system s documentation you can use the following information resources to help you use your server Se
70. sor then rotate the lever a full 135 to release the processor 7 Remove the old processor 8 Install the new processor into the processor socket Make sure that m The processor release lever is open all the way 135 from the closed position m The triangular arrow on the corner of the processor aligns with the triangular hole on the corner of the processor socket m The processor is flush with the socket Important If you install two processors onto the system board the processors can be different speeds Both processors will run at the lower of the two speeds 9 Press the processor locking lever down until it clicks into place 10 Apply thermal grease to the top of the processor if necessary 11 Place the heat sink on the processor then press the heat sink locking levers down until they click into place 54 www gateway com Installing a processor 12 1f your heat sink has a fan plug the fan into the connector on the system board next to the heat sink Processor 1 fan connector Processor 2 fan connector 13 it you have installed a new processor into the lower processor 2 slot for the first time you also need to install a voltage regulator for the processor If you ordered the processor from Gateway it came with a new voltage regulator For instructions on installing a voltage regulator see Installing a voltage regulator on page 56 Warning Only one voltage regulator should be installed for each
71. t you wrote down in Step 3 14 Save all your settings and close the BIOS Setup utility www gateway com 73 Chapter 4 Installing Components 74 www gateway com Using the BIOS Setup Utility Read this chapter to learn how to Open the BIOS Setup utility Update the BIOS Reset the BIOS settings to their factory defaults Reset the BIOS passwords 75 Chapter 5 Using the BIOS Setup Utility Opening the BIOS Setup utility The BIOS Setup utility stores basic settings for your server These settings include basic hardware configuration resource settings and password security These settings are stored and saved even when the power is off Caution The options in the BIOS Setup utility have been set at the factory for optimal performance Changes to these AN settings will affect the performance of your server Before changing any settings write them down in case you need to restore them later You can record the settings on a printout of BIOS Settings on page 107 gt To open the BIOS Setup utility 1 Restart your server 76 2 Press F2 when the Gateway logo screen appears during startup The BIOS Setup utility opens When you select menu items the Item Specific Help box on the right side of the screen displays specific information about the selection The command bar across the bottom of the screen shows the keys you press to access help navigate through the menus and perform other tasks 3 Select one
72. tation m See You need to troubleshoot an IDE hard drive on page 91 Insert bootable media device m Restart your server then open the BIOS Setup utility by pressing and holding F2 while your server restarts Make sure that the correct hard drive is set as the first bootable drive in the Boot menu m See Your server does not recognize an IDE drive on page 90 or Your server does not recognize a SCSI drive on page 90 for a possible solution Invalid configuration information m Restart your server then open the BIOS Setup utility by pressing and holding F2 while your server restarts Make sure that the settings are correct m Resetthe BIOS For more information see Resetting the BIOS on page 78 83 Chapter 6 Troubleshooting Invalid partition table m The master boot record may be corrupt For troubleshooting information see The master boot record is corrupted on page 91 Invalid password W Enter your password again Some passwords are case sensitive m If you do not know the password you may need to reinstall the software you are trying to access W System startup passwords are stored in BIOS If this password has been set and you do not know it you may be able to reset the password through system board jumper settings For more information see Resetting BIOS passwords on page 79 Memory errors were detected while the system started up W See Memory errors were detected during server start up on page 92 fo
73. th card press down on the card retention clip to secure the end of the card 50 www gateway com Installing PCI expansion cards 10 Connect any cables to the card For more information see the instructions in the card s documentation 11 Follow the instructions in Closing the server case on page 32 12 See the card s documentation for software installation instructions gateway com 51 Chapter 4 Installing Components Installing a processor The server is compatible with Intel Xeon processors with 512 KB cache The server automatically detects the processors each time you turn on the server Whenever you install new processors you should first install the most current version of the BIOS For more information see Updating the BIOS on page 77 Important You must have a processor in the upper processor 1 slot or your server will not start If you are upgrading your server from one processor to two you may need to reconfigure your operating system so it can recognize the additional processor For more information see your operating system s documentation Warning A heat sink must be installed on the processor Installing a processor without a heat sink could damage the D processor Warning Processors and heat sinks may be hot if the computer has been running Also there may be sharp edges on the heat D sinks Consider wearing protective gloves b To replace a processor 1 Install the most current BIOS v
74. to install or replace a diskette CD hard drive or tape drive P To install a 5 25 inch drive 1 Follow the instructions in Preventing static electricity discharge on page 27 2 Follow the instructions in Opening the server case on page 28 35 Chapter 4 Installing Components 3 If you are replacing a drive go to Step 7 OR If you are adding a new drive press and hold the two locking clips against the bay s 3 5 inch drive adapter then pull it out of the server 4 Press the drive bay face plate release tabs inward then pull the face plate away from the front cover 36 www gateway com Installing drives 5 If you are adding a 3 5 inch hard drive use the screws that came with your IDE hard drive to secure the drive to the 3 5 inch drive adapter IDE hard drive screws IDE hard drive screws OR www gateway com 37 Chapter 4 Installing Components If you are replacing the 3 5 inch drive adapter with a new 5 25 inch drive remove the two screws connecting each mounting rail to the adapter remove the rails then attach the rails to the sides of your new drive Mounting rail Mounting rail Screw j Mounting rail screw Mounting rail screw Two screws for mounting the rail onto CD and diskette drives are stored on each rail Screws for mounting onto most tape drives are stored in the case near the full length card retention clips Tape drive screws 6 Goto Step 11
75. twork protective operation and safety requirements The Department does not guarantee the equipment will operate to the users satisfaction Before installing this equipment users should make sure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection In some cases the inside wiring associated with a single line individual service may be extended by means of a certified connector assembly The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should make sure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Warning To avoid electrical shock or equipment malfunction do not attempt to make electrical ground connections by yourself D Contact the appropriate inspection authority or an electrician as appropriate The Ringer Equivalence Number REN assig
76. ware make sure that you have installed it following the instructions provided with it If you did not purchase the hardware or software from Gateway see the manufacturer s documentation and technical support resources If you have how to questions about using a program see m The program s online Help m The program s documentation m Your operating system s documentation m The software or hardware manufacturer s Web site See Troubleshooting on page 85 Have your client ID serial number located on the back of your server case and order number available along with a detailed description of your issue including the exact text of any error messages and the steps you have taken Make sure that your server is nearby at the time of your call The technician may have you follow appropriate troubleshooting steps Consider using Gateway s Internet technical support Gateway s Web site has FAQs tips and other technical help You can also use the Web site to e mail Technical Support For more information visit Gateway s Technical Support Web site at support gateway com Telephone support Gateway offers a wide range of customer service technical support and information services Telephone numbers You can access the following services through your telephone to get answers to your questions Resource Fax on demand support Tutorial support Gateway Technical Support Sales accounting and warranty Servi
77. way from the hot swap cage 11 Place the new backplane onto the hot swap cage then tighten the thumbscrew 12 Slide the hot swap cage part way into the hot swap bay Make sure that the side of the cage marked Top is oriented toward the top of the server case 13 Reconnect the power SCSI and manageability cables to the backplane 14 Slide the hot swap cage all the way into the hot swap bay then tighten the four thumbscrews 64 www gateway com Replacing the SCSI backplane 15 Reinstall the fan 16 Install each of the drives back into the hot swap cage Make sure that you replace the drives in the correct order by referring to your notes from Step 4 17 Follow the instructions in Closing the server case on page 32 www gateway com 65 Chapter 4 Installing Components Replacing the system board gt To replace the system board 66 1 2 Follow the instructions in Preventing static electricity discharge on page 27 Follow the instructions in Opening the server case on page 28 Remove the memory modules For more information see Installing memory on page 45 Remove all of the expansion cards For more information see Installing PCI expansion cards on page 47 Remove the heat sinks and processors For more information see Installing a processor on page 52 If your new system board does not include heat sink mounting brackets remove the heat sink brackets from you
78. y see the appropriate installation guide for instructions Maintaining Your Server Read this chapter to learn how to W Care for your server m Record the BIOS configuration m Manage your server and network 17 Chapter 3 Maintaining Your Server Caring for your server To extend the life of your server Be careful not to bump or drop your server When transporting your server we recommend that you put it in the original packaging materials Keep your server and magnetic media away from equipment that generates magnetic fields Avoid subjecting your server to extreme temperatures Do not expose your server to heating ducts or other heat generating objects Damage caused by extreme temperatures is not covered by your warranty As a general rule your server is safest at temperatures that are comfortable for you Keep all liquids away from your server When spilled onto server components almost any liquid can result in extremely expensive repairs that are not covered under your warranty Avoid dusty or dirty work environments Dust and dirt can clog the internal mechanisms and can cause the server to overheat Cleaning your server Keeping your server clean and the vents free from dust helps keep your server performing at its best Your server cleaning kit could include 18 A soft lint free cloth Glass cleaner An aerosol can of air with a narrow straw like extension Isopropyl alcohol Cotton swabs
79. you can try another update P To recover the old BIOS 1 Turn on or restart the server 2 Press and hold CTRL HOME The old BIOS is recovered 77 Chapter 5 Using the BIOS Setup Utility Resetting the BIOS The Clear BIOS jumper on the system board lets you return all BIOS settings to the factory defaults b To reset the BIOS 78 1 2 3 Print the appendix for BIOS Settings in this guide Restart your server Press F2 when the Gateway logo screen appears during startup The BIOS Setup utility opens Record any custom BIOS settings on your printout Follow the instructions in Preventing static electricity discharge on page 27 Turn off the server then disconnect the power cords and all other cables connected to the server Remove the side panel For more information see Opening the server case on page 28 Warning Moving the jumper while the power is on can damage your server Always turn off the server and unplug the power D cords and all other cables before changing the jumper Resetting the BIOS 8 Remove the jumper across pins 2 3 of jumper JP7 then place the jumper across pins 1 2 The BIOS memory is cleared Configuration jumper JP7 9 Place the jumper back onto pins 2 3 10 Follow the instructions in Closing the server case on page 32 11 Turn on the server A message appears saying that the CMOS Date and Time are not set 12 Press F1 to reset the BIOS to factory default settings

Download Pdf Manuals

image

Related Search

Related Contents

Samsung SVETA BMF con tecnología Digital Inverter, 328 L Manual de Usuario  Wiley OCP: Oracle Database 11g Administrator Certified Professional Study Guide: (Exam 1Z0-053)  7. 万一のとき    Mac OS X Server v10.6 - Mail Service Administration  Basler scout  Fiche de référence de génistéine plus  Cissell L28UR30 Clothes Dryer User Manual  