Home

Frigidaire FGMC2765PB Wiring diagram

image

Contents

1. 19 20 125 CL1251 3173 20 20 200 SEW 1 3122 CAUTION DISCONNECT POWER BEFORE SERVICING UNIT 21 22 125 3266 EY de LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS 22 22 150 10109 SWITCH WIRINGS ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION 23 18 200 3573 VERIFY PROPER OPERATION AFTER SERVICING 25 Es n Es E ATENCION CORTAR LA CORRIENTE ANTES DE REALIZAR EL MANTENIMIENTO DEL ELECTRODOMESTICO 2 2 as Habs WHT ji WC Lian ETIQUETE TODOS LOS CABLES ANTES DE DESCONECTAR CUANDO HAGA EL SERVICIO A LOS CONTROLES VOLTAGE 41 20 200 3512 CAPACITOR ERRORES AL VOLVER A ENSAMBLAR LOS CABLES PUEDE CAUSAR FALLAS U OPERACIONES PELIGROSAS VERIFIQUE LA CORRECTA OPERACION DESPUES DEL SERVICIO ATTENTION COUPEZ L ALIMENTATION AVANT D EFFECTUER LA REPARATION IDENTIFIEZ TOUS LES FILS AVANT DE LES DEBRANCHER QUAND L APPAREIL EST HORS SERVICE LES ERREURS DE CONNECTION DE FILS PEUVENT CAUSER UN MAL FONCTIONNEMENT ET UN DANGER D0003063 02 001 D USAGE DE L APPAREIL VERIFIEZ LE BON FONCTIONNEMENT DE L APPAREIL APRES LE SERVICE POWER TRANSFORMER FEUILLET DE DONEES TECHNIQU ES lectrom nager avec commande de four lectronique ES530 535 DESCRIPTION DES CODES D ERREUR wn Code Condition Cause Action corrective sugg r e AVIS Cette feuille de donn es d entretien est destin e aux
2. prise de courant qui est correctement FUSIBLE DE LA TEMP RATURE DE LA CAVIT P1 Sortie L2 l a Le fusible de la temp rature de la cavit situ sur le dessus de la cavit du four est d sign Entr e L2 P4 P11 P9 au MattenslElectriesleodesetaticeodos pour pr venir les dommages pouvant tre caus au four par un feu Si la nourriture est P5 Entr e L1 locaux et r glements situ e sur le dessus cuite outre mesure par soit une erreur de temps de cuisson ou par un d faut du contr le P7 Connecteur grillage J3 Sorties de relais Ventilateur convection P11 Entr e interrupteur de la porte interrupteur MDL et du four Dans l ventualit d un court C d du four le fusible de temp rature de la cavit s ouvrira pa P9 Connecteur cuisson MDL lumi re du four ventilateur sonde du four circuit la mise la terre r duit le risque de Lorsque le four est utilis normalement le fusible de la temp rature de la cavit demeure P11 Connecteur l ment convection refroidissement Entr e du courant L1 et choc lectrique en permettant au courant ferm Toutefois lorsque des temp ratures anormales sont atteintes dans la cavit du four P15 Entr e L1 Neutre lectrique de passer par le fil de mise e le fusible sautera 302 F 150 causant ainsi l arr t du four P17 Entr e L2 pas utilis e PISE NOTE C est un fusible Il ne peut pas tre r initialis
3. 5 c z z LT E cc ut W 6 z z N 22 m Dog HO me Qu z lt 2 gt E UE LT E E 22 giu 208 BK 8 a e L1 E TRE BK 7 6 8 TERMINAL BLOCK 1 BLOQUE DE CONEXION L2 R 8 R 7 R 7 DNI W 7 D W 6 Ey G 7 BLOC DE CONNEXION GND ELECTRONIC OVEN CONTROL CONTROL DE HORNO ELECTRONICO CONTROLE ELECTRONIQUE FOUR ES 530 W 5 MONITOR SWITCH MONITOR SWITCH DOOR SENSING SWITCH HUMIDITY SENSOR IE Note Indicates component Figure O 1 Oven Schematic Off Condition Figure O 2 Oven Schematic Cooking Condition E CONVECTION FAN ZX zz ui E LH VENTILADOR DE CONVECCION E AT amp 86 zB ES 51 VENTILATEUR CONVECTION DER V 14 conu LT 2 265 O J TOE SEP SONDA DE TEMPERATURA gt z nE LE SONDE THERMIQUE lt CE 5 lt XX n E _ gu 0 2 EI E CONVECTION FAN 14 5 gt CL oo gt gt QU D VENTILADOR DE CONVECCION 05 E LL lt 2 60 VENTILATEUR CONVECTION GY 14 gt 2 gt rOno 5 W 14 TON OP p o 7 R 14 ch O cc F D Qo W 35 5 Z a g 2E E DOOR SWITCH LL O 528 p i LATCH MOTOR INTERRUPTOR DE PUERTA OO i SE gy T O z Z S 3 2 MOTOR CERROJO INTERRUP
4. Ez g 5 45 22 du O lt MOTEUR_VERROU P 20 GY 20 lt x gt Q Z Zh gt lt TE gt d Bug 2 W 14 BR W 14z E X u u e uc be az c gt sa gs 3 OF OO uk L i 53 O EE Eg IS C Q T 2 IO amp os pE amp Us 25 OVEN LAMP OZ lt 5 Z a Leu T LUZ DE HORNO O z 50 O Q z zu OVOTOL EE E T T w m L 5 ETER LUMIERE FOUR z z ECz lt 5 9zou O LT E lt E TETE MOTOR SWITCH LATCH W oO Zz ui E TT INTERRUPTOR MOTOR DE LOQUETA DE PUERTA O ESO 0 T 14 INTERRUPTEUR MOTEUR VERROU O O WOLINOW s 5 m gt 2080501 0 14 GY 14 Z N co E HOLINOW VOIE OA O dA po Daga ea Urzzo gt NO EX rE LUZ DE HORNO z z 222 LUMIERE FOUR z z 1HM SEPVE IZ odzbhnt vg unk FA 25 ETER EEPO z A OUE 5 azz pues XL y 1 p ZO Ww EEE289 W 14 j T 14 14 2 pem cm Hd 4 T em CONNECTOR CONNECTOR CONNECTEUR FACULTATIF AH SENSOR FAN MOTOR E MEAT PROBE MOTEUR VENTILATEUR SONDE W 14 CON HIGH ALTA H
5. Coupe circuit thermique aussi dis PS Carte d alimentation lectrique NOTES IMPORTANTES Cet appareil inclut un contr leur de four lectronique Le que thermique ou limiteur thermique PS1 PS2 etc tableau de contr le n est pas r parable sur place INTERRUPTEUR SENSIBLE ET INTERRUPTEUR DE VERROUILLAGE PRIMAIRE Pratiques d entretien S curitaires e i L interrupteur de verrouillage primaire est mont la position la plus basse du support Pour viter tout risque de blessure et ou dommage mat riel il est important que Ha De ie de taquet et interrupteur sensible de la porte du syst me d interrupteur secondaire C bles plats mal branch s No communication pas entre le Coupez le courant lectrique V rifiez la connexion du c ble plat entre le panneau des Eis Apa a est mont la position la plus haute du support de taquet Ils sont activ par les t tes four et les contr leurs touches et le panneau EOC la tige P12 et P13 1 N essayez jamais de r parer un appareil si vous ne croyez pas avoir les com du taquet sur la porte Lorsque la porte est ouverte les interrupteurs interrompent Sile probl me persiste remplacez le p tences n cessaires pour le faire de mani re satisfaisante et s curitaire le courant toutes les composantes haut voltage Un cycle de cuisson ne peut Probl me avec le filage de sonde ou filage ouvert Note EOC 1 V rifiez si le filage de la
6. BR BROWN CAFE BRUN BL BLUE AZUL BLEU T TAN P PINK NOTE A The neutral WHT GRY wire must be connected to the terminal with mark on the power supply cord ENB CONNECTOR OPTION CONECTOR OPCION CONNECTEUR FACULTATIF BAKE ELEMENT MAGNETRON TEMP FUSE GAUGE CODIGO MEDIDA CSA ps ER ip n p n HU zi ss 9 L e 80 Eu P CPECLECCELCECECELECECELELECEEEECECECECECEEEE EE EEE EEE EEE EEE EEE xx 5 zl m CONVECTION FAN 5 d x 2 tt VENTILADOR DE CONVECCION NGOO 9 i AT E223 El zm z EM 2 T VENTILATEUR CONVECTION OPT TONI X14 o HSE z Xu E L ls839s 5 OPCION z ES 8 zu I amp o5sui TOT TEMPERATURE PROBE 252 z 2 m z E Ong FACULTATIF e QO _ uz 9 z z z SONDA DE TEMPERATURA X X LLI 220 z z SONDE THERMIQUE ge 2 xt EE E du gt QU oz 2 CONVECTION FAN 5 Z Z lt Z 55 2 VENTILADOR DE CONVECCION z T p zs A VENTILATEUR CONVECTION GY 14 2 e H HE B W 14 z z O LE GOu 3 8 R 14 Z 2 25 8 2 d DOOR SWITCH EI 2 LL I ii g LL spe usu 20 o 2 LATCH MOTOR z z INTERRUPTOR DE PUERTA O 3 9a lt A Z 5 E E o MOTOR CERROJO INTERRUPTEUR PORTE T z
7. MATRICE Sur le panneau relais Piden o affichage ERTSE FUSIBLE CONTR LE D ANALYSE DU F CEMENTS pem 1 Le fusible de contr le saute lorsque les contacts COM NO du relais de verrouillage CIRCUIT Moteur Venti Basse Ventil Haute DLB primaire RY2 et l interrupteur de verrouillage secondaire restent ferm s avec la Vent Conv verrou vitesse Vitesse L2 sortie de la porte Requis lectriques porte ouverte et lorsque l interrupteur de contr le est ferm P9 P7 J3 5 J3 4 J3 2 J3 1 P1 P11 4 P11 3 Les requis lectriques sont 120 volt 60 Hz AC seulement un fusible de protection is faced SHE Composantes e gangues Sonten e Pr chauffage x x x x du circuit 20 amp res est fourni en s rie avec la prise AC sur la dessus du four GOMTOIE SAUE POUF GNOG FUSIBLE DE LA TEMPERATURE DU MAGNETRON type classe cc Le fusible de la temp rature du magn tron est situ pr s du magn tron et est d sign se d veloppe dans le tube d une d faillance du ventilateur de refroidissement une MEN Es En condition normale le fusible de la temp rature de magn tron reste ferm Toutefois GrlComecion J 1 Es lorsque des temp ratures anormales sont atteintes dans le magn tron le fusible sautera Autonettoyant EX Ix p p qp Ho x x obstruction de la conduite de l air un blocage
8. de l vent etc RE CO EIE em ME Verrouillage D verrouitage bo x bo e op o ooo R DE CON CU NOTE C est un fusible II ne peut pas tre r initialis Meme o p px boo qo bo oo oo o E o REMETTRE LE CONTENU DANS LE SAC Porte Ouverte Jo o po x Po o o oro p e p o Jo j pb o do PS RE TE 807574801 Rev A 1 3 05 L l mentconvectionetsonventilateurfonctionnentseulementpendantle pr chauffage EE Le relais fonctionnera seulement dans cette condition NOH L3NDVIN OVEN CIRCUIT CIRCUITO DE HORNO CIRCUIT FOUR NOHIJNNDVN l ARMORED CABLE 120 VAC TUBO FLEXIBLE _ O EE FUSE 20A MICROWAVE OUTLET d R 8 f L2 R 8 Boy R 7 W 7 zE a 58 i Q z gt zg GE g UE Ws D Oz Cou uo wO xu W 6 E CEEE IS 25 UE TG 129955 22 E a ELE J EEEF BK 8 Li BK 7 Sunnonr G 8 TERMINAL BLOCK BLOQUE DE CONEXION G 7 BLOC DE CONNEXION GND ELECTRONIC OVEN CONTROL CONTROL DE HORNO ELECTRONICO CONTROLE ELECTRONIQUE FOUR ES 530 W 5 MONITOR SWITCH GRN GRN MONITOR SWITCH SENSING HUMIDITY SENSOR DOOR SENSING SWITCH Note Indicates component Figure O 1 Oven Schematic Off Condition Figure O 2 Oven Schematic Cooking Condition Y YELLOW AMARILLO JAUNE
9. personnes ayant Abr viation et terminologie de la fiche technique recu une formation en lectricit et en m canique et qui poss dent un niveau DEB lt Ligne Double tntenompus EOG de four lectroniqu F10 La commande a d cel e une condition possible d embal V rifiez la sonde RTD et remplacez la si n cessaire Si le four surchauffe d branchez le Si le de connaissance jug acceptable dans l industrie de r paration des appareils lement la commande pr sente un relais en court circuit et four continue de surchauffer remplacez le contr leur de four lectronique lectrom nagers Le fabricant ne peut tre tenu responsable ni assumer aucune LED Diode lectroluminescente MDL Moteur verrou de la porte RTD mauvais fonctionnement de la sonde responsabilit pour toute blessure ou dommage de quelque nature que ce soit pouvant r sulter de l utilisation de cette feuille de donn es RTD Sonde de temp rature VSC Commande de vitesse variable Touche en court circuit Si la commande d tecte qu une Appuyez sur ANNULER touche est appuy e pendant une longue p riode de temps Sile probl me persiste remplacez le EOC Elle sera consid r e en court circuit La commande g n re un signale sonore et teint le four F13 La m moire interne de la commande est corrompue Appuyez sur ANNULER Coupez le courant attendez 10 secondes et r tablissez le cou rant Si l erreur r appara t remplacez le EOC TCO
10. AUTE BL 14 E iiir O WHT z conductor of DOOR BLK the power supply cord has SENSING BLK been grounded by power SWITCH supply cord fixing screw COLORS CODIGOS DE COLOR CODE COULEUR 0 must always be ept tight z to Oven cavity CONVECTION ELEMENT z z BK BLACK NEGRO NOIR CAVITY TEMP FUSE PEMENTO DE COON COTON v CORD 120V 60H ELEMENT CONVECTION E z R RED ROJO ROUGE 0 6 6 ORANGE NARANJA ORANGE F TURNTABLE ELEMENTODE HORNO CODE CALIBRE pd PLEVENT 2 A6 2 p TN WHT h ANN 0 6 me ys ins 3 14 125 011251 3173 N AXX T P9 K5 4 12 125 11251 3173 BROIL ELEMENT 5 18 150 150 3321 S ELEMENTO DE ASADO pis BK 7 6 16 150 EXL 150 3321 CS ELEMENT GRILLAGE 7 14 150 EXL 150 3321 0 7 BL 7 8 12 150 EXL 150 3321 FAN MOTOR 9 10 150 EXL 150 3321 TT THERMAL CIRCUIT BREAKER 10 18 200 SEW 1 3122 INTERRUPTOR DE CIRCUITO TERMICO Hi 1e SEW 1 es DISJONCTEUR THERMIQUE dum DLB IN is 16 BED zem OVEN LAMP HIGH VOLTAGE COMPONENTS L3 14 20 150 EXL 150 3321 K1 EEG EXL 150 3321 ps R 7 SEW 1 3122 Wn HH HH HH LH EE HE E ELLE LL LL LLL LL LL LL LLL LL LLL LL LLL LL TITIN 19 20 125 CL1251 3173 20 20 200 SEW 1 3122 TET CAUTION DISCONNECT POWER BEFORE SERVICING UNIT 21 22 125 3266 mm EY T LABEL ALL WIRES PRIOR TO DISCONNECTION WH
11. EN SERVICING CONTROLS 22 22 150 10109 SWITCH lt WIRINGS ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION 23 18 200 3573 VERIFY PROPER OPERATION AFTER SERVICING iu us ec Rs ATENCION CORTAR LA CORRIENTE ANTES DE REALIZAR EL MANTENIMIENTO DEL ELECTRODOMESTICO 2n i SUO WHT ETIQUETE TODOS LOS CABLES ANTES DE DESCONECTAR CUANDO HAGA EL SERVICIO A LOS CONTROLES 41 20 200 3512 ERRORES AL VOLVER A ENSAMBLAR LOS CABLES PUEDE CAUSAR FALLAS U OPERACIONES PELIGROSAS VERIFIQUE LA CORRECTA OPERACION DESPUES DEL SERVICIO ATTENTION COUPEZ L ALIMENTATION AVANT D EFFECTUER LA REPARATION IDENTIFIEZ TOUS LES FILS AVANT DE LES DEBRANCHER QUAND L APPAREIL EST HORS SERVICE LES ERREURS DE CONNECTION DE FILS PEUVENT CAUSER UN MAL FONCTIONNEMENT ET UN DANGER D USAGE DE L APPAREIL VERIFIEZ LE BON FONCTIONNEMENT DE L APPAREIL APRES LE SERVICE POWER TRANSFORMER D0003063 02 001
12. SERVICE DATA SHEET Microwave Combination Unit with ES525 530 Electronic Oven Control NOTICE This service data sheet is intended for use by persons having DOOR SENSING AND PRIMARY INTERLOCK SWITCHES electrical and mechanical training and a level of knowledge of these subjects The primary interlock switch is mounted in the lower position of the latch hook and the Control has sensed a potential runaway oven condition Check RTD sensor probe and replace if necessary If oven is overheating disconnect Electronic Oven Control EOC Fault Code Descriptions generally considered acceptable in the appliance repair trade The manufac turer cannot be responsible nor assume any liability for injury or damage of control may have shorted relay and or RTD sensor probe power If oven continues to overheat when power is reapplied replace the Electronic door sensing switch in the secondary interlock system is mounted in the upper position may have gone bad Oven Control EOC Shorted Key A key has been detected as pressed for a 1 Press STOP key T MON COOKCYCIE long period Will be considered a shorted key alarm and 2 Ifthe problem persists replace the EOC ibn idis Bs unit includes an EOC electronic oven control This cannottake place until the door is firmly closed thereby activating both interlock switches will terminate all oven activit
13. TEUR PORTE Gc v gt MOTEUR VERROU 2 2 Z Nx lt Cou P 20 GY 20 a E g uoo 26 W 14 BR W 14 j E u 5 gt LLI T e TS 580 ja 2 O EO TD Eu Eg IE p O O X a ss dax m OVEN LAMP TE gu HE U LUZ DE HORNO 2 q dou E Eum Z _ Eu T O 29505 OOZ e E 2B E LUMIERE FOUR A Eng O Qe TH X lt 29505 MOTOR SWITCH LATCH T P ar HORS OO T lt INTERRUPTOR MOTOR DE LOQUETA DE PUERTA oO AFET uoo ETE T 14 INTERRUPTEUR MOTEUR VERROU O voz 3503 O lt JZ ur QO RTE f gt voz 35Na OA O GY 14 gt LEbos Z co lt YOLINOW Uca OVEN LAMP NO TUUM 22 U LUZ DE HORNO C Bass 9 FPE LUMIERE FOUR d 2 02632 EERE S uM Sun as W 14 T 14 T 14 2 4 m Bgemazo j E oUurzos iam am MEME E 1 noms j ETNen CONNECTOR CONNECTOR CONECTOR CONECTOR CONNECTEUR FACULTATIF AH SENSOR FAN MOTOR MEAT PROBE MOTOR DE VENTILADOR ow BAJA LENT Y 14 SONDA PARA CARNE SONDE A VIANDE COLORS CODIGOS DE COLOR CODE COULEUR W 14 Y HIGH ALTA HAUTE BL 14 NOTE The grounding conductor of the power supply cord has been grounded by power supply cord fixing screw The screw must always be
14. are properly and securely reassembled SENSING SWITCH SECONDARY INTERLOCK RELAY RY2 RELAY RY1 PRI Temperature F Resistance ohms MARY INTERLOCK SWITCH AND MONITOR SWITCH FOR PROPER OPERATION 32 1 9 0 1 0 1000 4 0 GROUNDING INSTRUCTIONS REFER TO CHAPTER TEST PROCEDURE 7512 5 24 1 3 1091 5 3 This oven is equipped with a three prong grounding plug It must be plugged into the wall oven receptacle that is properly installed and grounded in NOTE MONITOR FUSE AND MONITOR SWITCH ARE REPLACED AS AN AS 250 14 4 121 12 4 1453 8 9 accordance with the National Electrical Code and local codes and ordinances 350 5 4 177 3 0 1654 10 8 DN SEMBLY In the event of an electrical short circuit grounding reduces the risk of electric 450 6 9 232 3 8 1852 13 5 shock by providing an escape wire for the electric current CAVITY TEMPERATURE FUSE 550 8 2 288 4 5 2047 15 8 The cavity temperature fuse located on the top of the oven cavity is designed to prevent 650 9 6 343 5 3 2237 18 5 WARNING Improper use of the gt a di Iti sk damage to the oven by fire If the food load is overcooked by either error in cook time 900 13 6 482 7 5 2697 24 4 n Hans idi eo INE DA or defect in the control unit the cavity temperature fuse will open Probe circuit to case ground Open
15. circuit infinite resistance 1 1 4 K1 6 1 8 P1 L2Out Electrical Regui t Under normal operation the cavity temperature fuse remains closed However when ab P3 12 J35 een mda d normally high temperatures are reached within the oven cavity the cavity temperature fuse re EX A EXT The electrical requirements are a B P5 L1 Input will open at 302 F 150 C causing the oven to shut down Br BrolConnecor 120 volt 60 Hz AC only a branch J3 Relay Outputs Convection Fan Motor Door P11 Door switch Motor Door Latch Switch and circuit protection fuse 20 amp is P P9 Bake Connector provided in series with the ac outlet P11 Convection Element Connector on top of the wall oven support MONITOR FUSE L1 Input OVEN CIRCUIT On Relay Board On Display Board Latch Oven Light Cooling Fan Power Input L1 Oven Probe Inputs and Neutral 9 D eo Note B D the 0 1 The monitor fuse blows when the contacts COM NO of the primary interlock relay idet been Mi dimid a RY2 and secondary interlock switch remain closed with the oven door open and shall be replaced with class cc type MM when the monitor switch closes ANALYSIS ELEMENTS 2 f the wire harness or electrical components are short circuited this monitor fuse MATRIX Data Sheet Abbreviations and Terminology blows to prevent an electric shock or fire hazard Oven Light Conv Fan Door M
16. e door goes to a closed position the monitor switch contacts are first opened Door motor mechanism failure Motor If the motor does not rotate replace Lock Motor Assembly rior to returning the product to service ensure that 4 Check Lock Switch for proper operation do the contacts open and close check All alacttic conneclions correc and secure and then is door sensing switch and primary switch contacts close with ohmmeter The Da may E powered as in PU step to open and All electrical leads are properly dressed and secured away from On opening the door each of these switches operate inversely close Lock Switch If the Lock Switch is defective replace Motor Lock Assembly sharp edges high temperature components and moving parts 3 Ifthe door is opened and the secondary interlock relay RY2 and primary interlock 5 Ifall above steps fail to correct situation replace the EOC All uninsulated electrical terminals connectors heaters etc are adequately spaced away from all metal parts and panels e All safety grounds both internal and external are correctly and switch contacts fail to open the monitor fuse blows simultaneously with closing of Note Generally speaking F1X implies a control failure F3X an oven probe problem and F9x a latch motor problem the monitor switch contacts securely reassembled CAUTION BEFORE REPLACING A BLOWN MONITOR FUSE TEST THE DOOR peius All panels
17. ferm verrou est d fectueux remplacez le personnes et les biens condition ON puisque normalement il est ferm ce moment le relais verrouillage Si toutes les tapes mentionn es ci haut ont chou es remplacez le EOC secondaire RY2 et l interrupteur verrouillage primaire sont en position OFF contacts ouverts puisque normalement les contacts des interrupteurs sont ouverts 2 Lorsque la porte passe en position ferm e le contact de l interrupteur de contr le est le premier ouvert et ensuite les contacts de l interrupteur sensible de la porte et 6 Avant de retourner le produit au service de r paration ou d entretien as Surez vous que Toutes les connexions lectriques sont correctes et s curitaires Note G n ralement F1X signifie un probl me avec le contr leur F3X un probl me avec la sonde et F9X un probl me avec le moteur verrou de la porte CHELLE DU D TECTEUR DE TEMP RATURE Tous les conducteurs lectriques sont correctement pr par s et l abri de l int Ed trol didi tf te ch d R SISTANCE des bords tranchants des composants temp rature lev e et des pe up cu ii sur une porte ouverte chacun de Temp rature F R sistance ohms ces interrupteurs fonctionne de fa on invers e 3 Sila porte est ouverte et que les contacts du relais verrouillage secondaire RY2 32 1 9 0 1 0 1 000 4 0 Toutes les bornes lectriques connecteu
18. kept tight DOOR SENSING SWITCH to Oven cavity BK BLACK NEGRO NOIR G GREEN VERDE VERT W WHITE BLANCO BLANC R RED ROJO ROUGE O ORANGE NARANJA ORANGE Y YELLOW AMARILLO JAUNE BR BROWN CAFE BRUN BL BLUE AZUL BLEU T TAN P PINK CONVECTION ELEMENT ELEMENTO DE CONVECCION ELEMENT CONVECTION 0 6 V 6 POWER SUPPLY CORD 120V 60Hz NOTE A The neutral WHT GRY wire must be connected to the terminal with N mark on the power supply cord CN B CONNECTOR OPTION CONECTOR OPCION CONNECTEUR FACULTATIF BAKE ELEMENT CAVITY TEMP FUSE MAGNETRON TEMP FUSE GAUGE MEDIDA TEMP C CSA TURNTABLE ELEMENTODE HORNO ORG MOTOR ELEMENT CUISSON 1 CL1251 3173 x NI 2 16 125 011251 3173 ZRN 0 6 e Y 6 3 14 125 011251 3173 D K lt P9 4 12 125 CL1251 3173 S BEN BROIL ELEMENT Loxksexcas P 5 18 150 EXL 150 3321 d ELEMENTO DE ASADO P15LEK 7 6 16 150 EXL 150 3321 Es CS ELEMENT GRILLAGE 7 14 150 EXL 150 3321 0 7 BL 7 8 12 150 EXL 150 3321 FAN MOTOR 9 10 150 EXL 150 3321 WHT THERMAL CIRCUIT BREAKER 10 18 200 SEW 1 3122 INTERRUPTOR DE CIRCUITO TERMICO bs BE SEW 1 RES SECONDARY 0 7 DISJONCTEUR THERMIQUE 0 7 DLB IN 13 16 250 3252 OVEN LAMP HIGH VOLTAGE COMPONENTS L3 14 20 150 1 150 3321 ORE Ki EXL 150 3321 f EX SEW 1 3122
19. o probe resistance chart If tric outlet trip circuit breaker to Off or remove fuse primary interlock switch fail to open when the door is opened exists resistance does not match the chart replace the RTD sensor probe 3 Never interfere with the proper installation of any safety device Shorted RTD sensor probe wiring problem 3 Letthe oven cool down and restart the function 4 Use only replacement parts specified for this appliance Substitutions Functions 4 Ifthe problem persists replace the EOC may not comply with safety standards set for home appliances 4 5 Grounding The standard color coding for safety ground wires is green or green with yellow stripes Ground leads are not to be used as current When the door is opened the monitor switch contact close to the ON condition due to their being normally closed At this time the secondary interlock relay RY2 1 Turn off power for 10 seconds then turn on power Test tne door latch again try to start a Clean cycle carrying conductors It is extremely important that the service technician and primary interlock switch are in the OFF condition contacts open due to their 2 Ifitfails check wiring of Lock Motor Lock Switch and Door Switch circuits reestablish all safety grounds prior to completion of service Failure to do being normally open contact switches 3 Unplug the lock motor from the board and apply power L1 directly to the Lock zin ds a iin pria 2 As th
20. otor Cooling Fan Low Cooling Fan High DLB L2 Door Switch DLB Double Line Break EOC Electronic Oven Control Bake P9 Broil P7 Conv P11 Speed J3 2 Speed J3 1 P11 4 P11 3 MAGNETRON TEMPERATURE FUSE LED Light Emitting Diode MDL Motor Door Latch The magnetron temperature fuse located near the magnetron is designed to prevent Preheat x x x j x x fan failure obstructed air guide dirty or blocked air intake etc etc Detector Oven Probe disc or thermal limiter when abnormally high temperatures are reached within the magnetron the magnetron temperature fuse will open at 302 F 150 C causing the oven to shut down IMPORTANT Convecion Roast x x x JgjJ x j x j x j x x J x j x j x x DO NOT REMOVE THIS BAG gen Jg qQ X x j x OR DESTROY THE CONTENTS Lesung I bowo RS VE bocsa 0 RS D 807574801 EN Rev A 1 3l 05 Convection element and fan are used for the first rise of temperature Relay will operate in this condition only WIRING DIAGRAMS AND SERVICE INFORMATION ENCLOSED REPLACE CONTENTS IN BAG GENERAL TROUBLESHOOTING SCHEMATIC MICROWAVE GENERAL TROUBLESHOOTING SCHEMATIC OVEN vouno p OVEN CIRCUIT CIRCUITO DE HORNO CIRCUIT FOUR DH t 2 m 24 se
21. rs r chauffeurs etc d nud s td ji t teurd mare cch tar 9 le fusible d H 75225 24413 1091453 sont espac s convenablement loin de toute pi ce en m tal et des et de l interrupteur de contr le primaire c ouent l ouverture le fusible de contr le 2 1 5 saute et en m me temps le contact de l interrupteur de contr le se ferme 250 4 4 121 2 4 1 453 8 9 Toutes les mises la terre de s curit interne et externe sont correcte m Dec 350 5 4 177 3 0 1 654 10 8 ment rassembl es de fa on s curitaire Lo 1 He Tous les panneaux sont correctement et fermement remont s i n 2047 158 verrouillage primaire et l interrupteur de contr le fonctionnent correctement R f rez 550 8 2 288 4 5 ADAT ETS gt 650 9 6 343 5 3 2237 18 5 INSTRUCTIONS DE MISE LA TERRE vous la section proc dure de TEST 900 x 13 6 482 7 5 2 697 24 4 Cet appareil est muni d une fiche _ NOTE Le fusible d tr le et l int t tr l t t T bl mM Le fusible de contr le et l interrupteur contr le peuvent tre remplac ensemble Circuit de la sonde mise la Circuit ouvert r sistance infinie terre la caisse d alimentation lectrique trois fils mise y la terre Elle doit tre branch e la E KT K5 K3 K9 IK11IK14IK 16 K 18 a J3 RE P3
22. sonde qu il n est pas en court circuit 2 Avant de proc der au service d entretien ou de d placer tout appareil pas fonctionner tant que la porte n est pas completement ferm e ce qui activent les affiche initialement le code F 10 signifiant qu il d c le une V rifiez la r sistance RTD la temp rature de la pi ce comparez la valeur avec le tab m nager d branchez le cordon d alimentation de la prise lectrique r glez interrupteur de verrouillage Le syst me d interrupteur de verrouillage secondaire condition d emballement leau Si celle ci ne concorde pas avec le tableau remplacez le senseur de la sonde RTD le disjoncteur de circuit OFF ou enlevez le fusible et fermez le robinet d ali consiste en un interrupteur sensible et un relais de verrouillage secondaire situ s sur la Court circuit de la sonde probl me de filage Laissez refroidir le four et red marrez la fonction mentation en gaz plaque de s rie Sile probl me persiste remplacez le 3 N entravez jamais l installation ad quate de tout dispositif de s curit 4 Utilisez que les pi ces de remplacement num r es dans le catalogue pour L INTERRUPTEUR DE CONTROLE cet appareil La moindre substitution risque de ne pas tre conforme aux L interrupteur de contr le est activ les contacts sont ouverts par la t te du taquet J Coupez le courant lectrique pendant 10 secondes et r appliquez le courant par la suite normes de s curit
23. tablies pour les appareils lectrom nagers sur la porte lorsqu elle est ferm e L interrupteur est destin rendre le four inactif V rifiez le filage du moteur verrou de l interrupteur et le circuit de l interrupteur de la porte 5 Mise la Terre La couleur de codage standard des conducteurs de mise la en faisant sauter le fusible de contr le lorsque le contact du relais du verrouillage D branchez le moteur du EOC et branchez L1 directement au moteur Si le moteur terre de s curit est verte ou verte barres jaunes Les conducteurs de mise secondaire RY2 et l interrupteur de verrouillage primaire chouent l ouverture lorsque tourne pas remplacez l assemblage du moteur la terre ne doivent pas tre utilis s comme conducteurs de courant Il est la porte est ouverte 2 Syst me de verrouillage de porte d fectueux V rifiez si les interrupteurs fonctionnent correctement Est ce qu il permet de fermer et d une importance capitale que le technicien d entretien compl te toutes les d ouvrir la porte V rifiez avec un ohm m tre Le moteur verrou doit tre r activ tel mises la terre de s curit avant de terminer le service Si cette recom Fonctions qu indiqu l tape pr c dente afin que l interrupteur s ouvre et se ferme Si l interrupteur mandation n est pas suivie la lettre il en r sultera des risques pour les 1 Lorsque la porte est ouverte le contact de l interrupteur de contr le est
24. y oard is not field repairable Lis secondary interlock system of the door sensing switch and secondary F13 Control s internal checksum may be corrupted Press CLEAR key Disconnect power wait 10 seconds and reapply power If fault Safe Servicing Practices interlock relay located on the control circuit board returns upon power up replace EOC To avoid the possibility of personal injury and or property damage it is import Misconnected flat cables No communication between oven 1 Disconnect power Verify the flat cable connection between the touch panel or that oe ped D be observed The following are some but not MONITOR SWITCH And cantrols membrane and the EOC on P12 and P13 VE dad NES T The monitor switch is activated the contacts opened by the latch head on the door while 2 Ifthe problem persist replace the EOC 1 Do not attempt a product repair if you have any doubts as to your ability M M to complete it in a safe and satisfactory manner the door is closed The switch is intended to render the oven inoperative by means of Open RTD sensor probe wiring problem Note EOC may 1 Check wiring in probe circuit for possible open or short condition 2 Before servicing or moving an appliance remove power cord from elec blowing the monitor fuse when the contacts of the secondary interlock relay RY2 and initially display an F10 thinking a runaway condition 2 Check RTD resistance at room temperature compare t

Download Pdf Manuals