Home
Frigidaire FFEC3625LS Product Specifications Sheet
Contents
1. no cooktop Critica or installation guide on web 27 Electric Single Wall Oven GLEB27Z7H Under Counter Installation Specifications e Single phase 3 or 4 wire cable 120 240 or 120 208 Volt 60 Hertz AC only electrical supply with ground required on separate circuit used on both sides of line For detailed electrical requirements refer to mode page and installation guide on web Always consult local and national electric codes inimum 27 1 4 clearance for oven door depth when open inimum 23 1 2 deep cutout dimension is critical for proper installation to ensure that oven s faceplate will fit flush against cabinet front inimum 4 1 2 distance required from door hinge cutout opening to any adjoining cabinetry or wall clearance for oven rack removal e Side filler panels necessary to isolate oven from adjoining cabinets e Oven base of solid plywood or similar material required capable of supporting 150 Lbs Install over two runners and flush with toe plate e Base must be level and cabinet front must be square Recommended that bottom of cabinet remain partially opened to permit free air circulation avoiding possible water condensation which may appear inside control panel while operating oven Allow 5 maximum height from oven base to floor if NO cooktop is installed directly over wall oven specific product side of oven s o allow sufficient FRIGIDAIRE USA 10200 David Taylor Drive C
2. to junction box i cut minimum 4 x 4 opening in wood base Oven 29 max 2 from left side filler panel 27 Wall 24 7 s min 240 208V Junction box for electric Install 3 4 full plywood base on 2 runners flush with toe plate capable of supporting 200 Ibs 30 models or 150 Ibs 27 models Cutout Width A 30 Wall 28 2 min Oven 25 1 max Critical dimension MUST be applied For cooktop cutout dimensions refer to model specific product page or installation guide on web tThis installation drawing excludes model GLEB27Z7H with side swing door Electric Cooktop Installation Over 30 27 Electric Single Wall Oven Specifications All Frigidaire Electric Single Wall Ovens are approved to be used beneath any approved Frigidaire Electric Cooktop This installation page excludes approved wall oven model GLEB27Z7H For model specific installation details refer to Electric Cooktop Installation Over 27 Electric Single Wall Oven GLEB27Z7H Specifications pages on web For detailed Electric Cooktop installation refer to model specific product page and installation guide on web Side filler panel height may need to be modified to accommodate the depth of approved electric cooktop models To route armored cable to junction box cut minimum 4 x 4 opening in right side filler panel Allow 4 1 2 maximum height from oven base to floor if cooktop is installed directly over wall oven No
3. FRIGIDAIRE Built In Cooktops FFECS625L S7 W E Signature Features Ready Select Controls Select options or control cooking temperature with our easy to use controls Keep Warm Zone Keep food warm until everything and everyone is ready 36 Electric Product Dimensions Width 36 3 4 Depth 21 3 8 Height 3i More Easy To Use Features Ceramic Glass Cooktop For a more beautiful cooktop that s easy to clean Color Coordinated Control Knobs White and Black cooktops come with matching knobs while Stainless Steel models feature our neutral black knobs Hot Surface Indicator Alerts you when your cooktop may be too warm to touch Available in Stainless White Black S Ww B Elements Size Watts Right Front E 72500077 Right Rear TA 1 500 Left Front 12 2 700 Left Rear 6 1 200 Center Keep Warm 100 Zone Extra Large Element Our extra large 12 element gives you space for larger pots and pans Approved Over Frigidaire Electric Wall Ovens Cooktops are approved for installation above any of our Electric Single Wall Ovens frigidaire com FRIGIDAIRE Features Controls Ready Select Surface Type Black Ceramic Glass S Color Coordinated Ceramic Glass W B Right Front Element Watts O22 50 0 Right Rear Element Watts 7 1 500 Left Front Element Watt
4. N L5V 3E4 1 800 265 8352 frigidaire ca FFEC3625L 02 14 2014 Electrolux Home Products Inc on the web at frigidaire com Specifications subject to change FRIGIDAIRE 4 x 8 opening to route armored cable if base is present G min between rear edge of cutout and nearest combustible surface or backsplash above countertop Product Dimensions A Width 36 3 4 Product Cutout Dimensions D Width min max 35 7 8 36 1 8 E Depth min max 20 1 4 20 1 2 Built In Cooktop Specifications Product Shipping Weight approx 65 Lbs e Single phase 3 or 4 wire cable 120 240 or 120 208 Volt 60 Hertz AC only electrical supply with ground required on separate circuit used on both sides of line Connected Load kW Rating 240 208 Volts 8 1 6 1kW Amps 240 208 Volts 33 8 29 3 Amps Recommended Circuit Breaker 40 Amps Always consult local and national electric codes Cooktop cutout height includes clearance needed beneath cooktop to allow for armored cable and installation of junction box on back wall Position center of junction box 10 inward from right side of cooktop cutout and 12 down from underside of countertop Overhead cabinetry should not exceed a 13 maximum depth Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than 36 3 4 e Allow 30 minimum clearance between top of cookto
5. aximum height allowed from oven base to floor if cooktop is installed directly over wall oven 5 maximum height allowed with no cooktop 30 27 Electric Single Wall Oven Under Counter Installation Specifications e Single phase 3 or 4 wire cable 120 240 or 120 208 Volt 60 Hertz AC only electrical supply with ground required on separate circuit used on both sides of line For detailed electrical requirements refer to model specific product page and installation guide on web Always consult local and national electric codes inimum 21 clearance for oven door depth when open inimum 23 1 2 deep cutout dimension is critical for proper installation to ensure that oven s faceplate will fit flush against cabinet front Side filler panels necessary to isolate oven from adjoining cabinets Full oven base of solid plywood or similar material required capable of supporting 200 Lbs 30 models or 150 Lbs 27 models nstall over two runners and flush with toe plate e Base must be level and cabinet front must be square Allow 5 maximum height from oven base to floor if NO cooktop is installed directly over wall oven FRIGIDAIRE USA 10200 David Taylor Drive Charlotte NC 28262 1 800 FRIGIDAIRE frigidaire com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 frigidaire ca EC_EW INST FR 11 13 Unit will overlap cutout minimum edges by 1 To route armored cable
6. harlotte NC 28262 1 800 FRIGIDAIRE frigidaire com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 frigidaire ca EC_EW_SS INST FR 11 13 dimension MUST be applied For cooktop cutout dimensions refer to model specific product page Note Recommended that bottom of cabinet remain partially opened to permit free air circulation avoiding possible water condensation which may appear inside control panel while operating oven Electric Cooktop Installation Over 27 Electric Single Wall Oven GLEB27Z7H Specifications Frigidaire Single Wall Oven model GLEB27Z7H is approved to be used beneath any approved Frigidaire Electric Cooktop For detailed Electric Cooktop installation refer to model specific product page and installation guide on web Side filler panel height may need to be modified to accommodate the depth of approved electric cooktop models To route armored cable to junction box cut minimum 4 x 4 opening in right side filler panel Allow 4 1 2 maximum height from oven base to floor if cooktop is installed directly over wall oven Note For planning purposes only Refer to Product Installation Guide on the web at frigidaire com for detailed instructions Specifications subject to change 2013 Electrolux Home Products Inc
7. p platform and bottom of unprotected wood or metal overhead cabinet or 24 minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1 8 flame retardant millboard covered with not less than No 28 MGS sheet steel 0 015 stainless steel 0 024 aluminum or 0 020 copper FRIGIDAIRE USA 10200 David Taylor Drive Charlotte NC 28262 1 800 FRIGIDAIRE frigidaire com CANADA 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 frigidaire ca FFEC3625L 02 14 Plywood base optional F Height min min Built In Cooktops FFEC3625L S W B 36 Electric unprotected cabinet 24 min for protected cabinet Includes clearance needed beneath cooktop to allow for armored cable and installation of junction box on back wall 1 min from right edge of cooktop to nearest combustible wall J min from edge of cutout to front edge of countertop H min from left edge of cooktop to nearest combustible wall Required Clearances K Cabinet Opening Width Utility Connection Locations Power Supply e Allow 2 minimum clearance between rear edge of cutout and nearest combustible surface or backsplash above countertop Allow 7 1 2 minimum required clearance from left edge of cooktop to nearest combustible wall and 7 1 2 minimum from right edge of cooktop to nearest combustible wall Installation of drawer beneath cooktop requi
8. res 4 minimum clearance beneath countertop surface and assured clearance for electrical installation To reduce risk of fire when using overhead cabinetry install range hood that projects horizontally a recommended minimum of 5 beyond bottom of cabinets e Electric Drop In Cooktop model FFEC3625L is approved to be used over any Frigidaire Electric Single Wall Oven Refer to Electric Cooktop Installation Over 30 27 Electric Single Wall Oven Specifications page on web Note For planning purposes only Refer to Product Installation Guide on the web at frigidaire com for detailed instructions Optional Accessories e Granite Countertop Installation Kit PN 903061 9010 Accessories information available UL on the web at frigidaire com Specifications subject to change 2014 Electrolux Home Products Inc FRIGIDAIRE Electric Cooktop Installation Over 30 27 Electric Single Wall Oven For all approved electric cooktop models cut minimum 4 x 4 opening in right side filler panel to route armored cable to junction box Side filler panels necessary to isolate oven from adjoining cabinets Panel height may need to be modified to accommodate depth of approved electric cooktop models Electric Single Wall Oven Cutout For all 30 amp 27 modelst 4e Plywood min a i 1 L 1 1 1 1 1 1 Approx 3 240 208V Junction box X 0 for wall oven 0 iss 24 min cutout depth 4 1 2 m
9. s 12 2 700 Left Rear Element Watts 6 1 200 Keep Warm Zone 6 100 Hot Surface Indicator Yes Control Location Right Side Knob Color Black S Color Coordinated W B Knob Type Plastic Specifications Power Supply Connection Location Right Rear Voltage Rating 240V 208V 60Hz Connected Load 81 61 kW Rating 240 208 Volts Amps 240 208 Volts 33 8 29 3 Minimum Circuit Required Amps 40 Approved for Electric Single Wall Oven Wing Combination Installation Shipping Weight Approx 65 Lbs Single phase 3 or 4 wire cable 120 240 or 120 208 Volt 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line 2Cooktops are approved for installation above any of our Electric Single Wall Ovens FRIGIDAIRE Built In Cooktops FFEC3625L S W B 36 Electric NOTE Always consult local and national electric codes Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire com Product Dimensions Cutout Dimensions A Width 36 3 4 Width Min 35 7 8 B Depth 21 3 8 Width Max _36 1 8 C Height 3 Depth Min _20 1 4 Depth Max _20 1 2 Height E Granite Countertop Installation Kit available Accessories information available USA 10200 David Taylor Drive Charlotte NC 28262 1 800 FRIGIDAIRE frigidaire com CANADA 5855 Terry Fox Way Mississauga O
10. te For planning purposes only Refer to Product Installation Guide on the web at frigidaire com for detailed instructions Specifications subject to change 2013 Electrolux Home Products Inc FRIGIDAIRE Gyer 27 Electric Cooktop Installation Electric Single Wall Oven GLEB27Z7H For all approved electric cooktop models cut minimum 4 x 4 opening in right side filler panel to route armored Side filler panels necessary to isolate oven from adjoining cabinets Panel height may need to be modified to accommodate depth of approved electric cooktop models Electric Single Wall Oven Cutout For 27 model GLEB27Z7H with side swing door Approx 3 a Plywood 240 208V Junction box J O for wall oven Ss 24 min cutout depth 4 1 2 maximum height allowed from oven base to floor if cooktop cable to junction box 240 208V Junction box for electric cooktop Oven cutout 36 min Na 28 Ye min 28 5s max Install 3 4 plywood base on 2 runners flush with toe plate capable of supporting 150 Ibs Minimum 4 2 distance required from door hinge side of oven s cutout opening to any adjoining cabinetry or wall to allow sufficient clearance for oven rack removal To route armored cable to junction box cut minimum 4 x 4 opening in wood base 2 from left side filler panel is installed directly over wall oven 5 maximum height allowed with
Download Pdf Manuals
Related Search
Related Contents
Service Manual AH 271 - rev 2 the User Guide Targus Drifter Sport 14" MV3-E Series Installation and Operation Manual for Hybrid Engine cas Télécharger le fichier PDF H.264 IP Camera User Manual User Manual - ICP DAS USA`s I Samsung GE614W manual de utilizador Copyright © All rights reserved.
Failed to retrieve file