Home

Fluke Ti10 User's Manual

image

Contents

1. 2 Press the softkey labeled Up or Down to toggle the display between PIP and Full IR 3 Press the softkey labeled Back Done when finished Setting IR Fusion and PIP Ti25 and TiR1 Only Blending a visual image with a thermal image is called IR Fusion The Imager is set to one of three different levels of blending In addition to setting the visual to thermal blending the IR Fusion menu is used to select between a full thermal image display or a Picture In Picture PIP display To set the IR Fusion level and PIP display 1 Press 6 until IRFusion appears over f 2 Press the softkey labeled IRFusion to reveal the IR Fusion menu 3 Press the softkey labeled Up or Down to move between the six IR Fusion settings The top three settings select a PIP display The bottom three settings have full screen IR with different levels of visible blending 4 Press the softkey labeled Back Done when finished Reviewing and Deleting Stored Images To view stored images on the SD card 1 Press 6 until Memory appears over 2 Press the softkey labeled Memory to reveal the review menu 3 Press the softkey labeled Review 10 Thermal Imagers Adding Voice Annotation to Saved Data Ti25 and TiR1 Only 4 Press the softkey labeled Up to display the previous image or Down to display the next stored image To delete a single Image from the SD card 1 Perform the steps under viewing stored images above to bring the desi
2. TH10 1125 TIR and TIR Thermal Imagers Users Manual PN 2803044 August 2007 2007 Fluke Corporation All rights reserved Printed in USA All product names are trademarks of their respective companies LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service The warranty period is two years and begins on the date of shipment Parts product repairs and services are warranted for 90 days This warranty extends only to the original buyer or end user customer of a Fluke authorized reseller and does not apply to fuses disposable batteries or to any product which in Fluke s opinion has been misused altered neglected contaminated or damaged by accident or abnormal conditions of operation or handling Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non defective media Fluke does not warrant that software will be error free or operate without interruption Fluke authorized resellers shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of Fluke Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price Fluke reserves the right to i
3. Data Note Minimum focus distance for thermal IR camera is 15 cm approx 6 inches Minimum focus distance for visible visual light camera is 46 cm approx 18 inches Note The Imager can save the image as a simple picture or as a radiometric image that allows further temperature analysis To change the saved image format see the Setting File Format section later in this manual Note When IR Fusion is enabled adjusting the IR focus control will align the IR and visible light images on the LCD display When the IR image is properly focused the images should be almost perfectly aligned This functionality provides an east method to get a good focus on the IR image Because of image parallax and minimum focus specifications the minimum distance for an aligned IR Fusion image is approximately 46 cm 18 inches Pressing the softkey labeled Settings allows modification of image characteristics such as palette picture in picture and range Refer to the appropriate setting section for operational details Saving Imager Data The Imager saves displayed data on an SD card placed into the camera See the Changing the SD Card section for inserting and ejecting an SD card The file format set on the Imager determines how the measured information is stored on the SD card To store Imager data 1 Point camera at the area of interest and pull the trigger to capture an image This will freeze the image in the display
4. Setting Emissivity Ti25 and TiR1 only Setting your Imager with correct emissivity values is critical to making accurate temperature measurements To set the emissivity value 1 Press until Emissivity appears over 2 Press the softkey labeled Emissivity At this point emissivity can be set directly as a value or selected from a list of emissivity values for some common materials To select from a list of common materials 1 Press the softkey labeled Table 2 Press the softkey labeled Up or Down to move between the materials in the list The emissivity value for each material is shown on the screen as the selection moves between the different materials 3 Press the softkey labeled Done to select the highlighted material 13 Ti10 Ti25 TiR and TiR1 Users Manual To set the emissivity value directly 1 Press the softkey labeled 2 Press the softkey labeled Up or Down to increment or decrement respectively the emissivity value displayed just above the softkey labels 3 Press the softkey labeled Done to select the set value Setting File Format Data stored on the Imager s SD card can be saved in two different file formats bmp and is2 This setting is saved and remains valid when the Imager is turned off and back on It can always be changed prior to capturing images To change the file format 1 Press o until File Format appears over softkey F3 2 Press the softkey labeled File Format 3 Pres
5. included Power BANEN oa n sole stile dtnciwtadteuaeass Rechargeable battery pack included Baten LitG scarcer vena naa apes 3 to 4 hours continuous use assumes 50 brightness of LCD Battery Charge Time ccccceseceeeeesseeeeeeeneeees 2 hours full charge with ac adapter or dc car charger AC Operation CharQing cscccssseeeseeeeeeeeeees AC adapter charger 110 220 Vac 50 60 Hz Charges battery while imager is operating Universal ac mains adapters included POWE SAVING sra a a Sleep Mode activated after 5 minutes of inactivity Automatic Power Off after 30 minutes of inactivity Safety Standards GE Directive ssaernuen ie a cee IEC EN 61010 1 2 Edition Pollution Degree 2 Electromagnetic Compatibility EMG Directives a E a EN61326 1 C TICK i a a aledtanle Gite awe iedante Gls IEC EN 61326 MG Geass a et cnt a sree recs ban tee nate E A CFR 47 Part 15 Class A Vibration sons Sa cess cs ag sain ea 2 G IEC 68 2 29 STOCK sii acest a a a a 25 G IEC 68 2 6 DrOD esnea a peoiteieal en seeseei ee 2 meter drop all sides Size H x W xX L isiseicisuadcarievavernieuancusasrareiaiguateibdeuns 10 in x 5 in x 6 in 25 4 cm x 12 7 cm x 15 2 cm WY SUC ssis oicdy ta ottesamostieneiegnaceass 1 1 kg 2 35 Ib Enclosure Rating ccceeeeeeeeeeeeeeeeeeeenees IP54 Warranty e a AA eas ce amegdian oes 2 years Calibration Cycle cccccccccssseeeeeeeeeseeeeeeneees 2 years assumes normal operation and
6. Card Setting the BAC i OG sched cssocesclecndiedadandacexescestesnereadeaatadadtanasedeesadnel General Specifications Detailed Specifications List of Tables Table Title Page be ROVE DOUS eE 2 Features and Controls c cccccccsccsceccecceccsccscescescescecescescescess Figure Title Page 1 Range and Span Settings 00 cccesssssesseeeeeeeeeeeeeeeeeeeeeeeeeenees iii Ti10 Ti25 TiR and TiR1 Users Manual Introduction The Fluke T110 T125 TiR and TiR1 Thermal Imagers hereafter the Imager are handheld imaging cameras used for predictive maintenance equipment troubleshooting and verification All four Imagers produce thermal and visual images on a 640 X 480 display Thermal and visual images are displayed on the Imager LCD and can be saved to an SD Memory card Transferring images to a PC is accomplished by removing the SD memory card and connecting it to a PC through the included card reader SmartView software is included for image analysis and report generation from these saved images Both thermal and visual images can be presented simultaneously as a full fusion thermal displayed over visual image or as a Picture In Picture PIP image The thermal image temperature range starts at 20 C and goes up to 100 C for the TiR and TiR1 250 C for the T110 and 350 C for the T125 The thermal image can be displayed using any one of a number of color palettes depending on the model Imager power i
7. DING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES INCLUDING LOSS OF DATA ARISING FROM ANY CAUSE OR THEORY Since some countries or states do not allow limitation of the term of an implied warranty or exclusion or limitation of incidental or consequential damages the limitations and exclusions of this warranty may not apply to every buyer If any provision of this Warranty is held invalid or unenforceable by a court or other decision maker of competent jurisdiction such holding will not affect the validity or enforceability of any other provision Fluke Corporation Fluke Europe B V P O Box 9090 P O Box 1186 Everett WA 98206 9090 5602 BD Eindhoven U S A The Netherlands 11 99 To register your product online visit register fluke com Table of Contents Title Page TAH OCC n O AEE ETAT Contacting Te WKS sessseeiooceecne rrean EE Safety Intormafi Oiss siinne anaia aiii Unpacking the MAET s c002 s cdsvcerendascesesdersedaedddesdeecesaedaeddesnesneece Charging the Battery cccccccccceccccceceeeeceeeeeeeaaeeeeeseeeeeeeeeeees Turning the Imager On and Off cessseseseeeeeeeeeeeeeeeeeeaes Features and Control sieiiccvancsssncnswicnsvaieisanecnetinasen nebeosseevecestehenees Usine the Memi rsisi E i e a Changing the Displayed Language nneseeeeeesssessssssssseseee
8. Imager connected to battery 4 Audio recording associated charger with the displayed image On Off Symbol Imager in sleep mode or audio paused Do not dispose of this product as unsorted municipal waste Go to Fluke s website for recycling information Thermal Imagers Unpacking the Imager Unpacking the Imager Carefully unpack the following items e Ti10 T125 TiR or TiR1 Imager e AC Power Adapter Charger e Rugged Carrying Case e SD Memory Card e SD Card Reader e Soft Transport Bag e User Manuals in various languages e SmartView Software e Warranty Registration Card Charging the Battery Before using the Imager for the first time charge the battery for at least two hours The Imager s battery condition is displayed in the upper left corner of the display When the last segment of the battery icon extinguishes the Imager will shut down and will require recharging before operating again To charge the Imager s battery 1 Plug the ac input of the battery charger into an ac wall outlet 2 Plug the battery charger s dc output into the Imagers ac adapter socket The optional Car Charger can also be used to recharge the Imager s battery While the battery is charging the battery icon appears as while the Imager is operating With the Imager off appears in the display while connected to the battery charger Turning the Imager On and Off To turn the Imager on or off press the center softkey
9. and bring up the Image Capture menu 2 Press the softkey labeled Store If the SD card is in the Imager and there is enough room left on the card the information is stored Adjusting the Thermal Image The Imager uses different colors or shades of gray to display the temperature gradient of the area within the Imager s field of view There are two adjustments for changing how the Imager displays the image Palette and Range Ti10 Ti25 TiR and TiR1 Users Manual Selecting a Palette The palette menu provides different thermal viewing patterns Grayscale Blue Red High Contrast and Ironbow are available in all four Imagers The TiR1 and Ti25 add Amber and Hot Metal to the list To select a palette 1 Press until Palette appears over 2 Press the softkey labeled Palette to display the available palette options 3 Press the softkey labeled Up or Down to move between the palette options 4 Press the softkey labeled Back Done to set the Imager to the selected palette Setting the Range Viewing temperature level and span is set either automatically or manually To set the range do the following 1 Press 6 until Range appears over f 2 Press the softkey labeled Range 3 Press the softkey labeled Manual to set the Imager to manual ranging and press the softkey labeled Auto to select auto ranging Thermal Imagers Adjusting the Thermal Image exj02 eps Figure 1 Range and Span Settings Setting th
10. e Level Manual When put into manual ranging the level setting adjusts the thermal span within the total temperature range of the Imager See Figure 1 To set the level 1 After entering the manual range mode See the Setting the Range section above press the softkey labeled Level 2 Press the softkey labeled Up to move the temperature span to higher temperatures or Down to move the span to lower temperatures 3 Press the softkey labeled Done to set the Imager s range level The scale along the right side of the display indicates the range Setting the Temperature Span Manual When put into manual ranging the span setting adjusts the palette over a temperature range within the total range of the Imager See Figure 1 To adjust the temperature span 1 After entering the manual range mode See the Setting the Range section above press the softkey labeled Span Ti10 Ti25 TiR and TiR1 Users Manual 2 Press the softkey labeled Increase to widen the temperature span or Decrease to narrow it 3 Press the softkey labeled Done to set the Imager s range level Switching Between PIP and Full IR Ti10 and TiR Only The Imager can be set to display a full infrared image Full IR or an infrared image surrounded by a visual light image Picture in Picture PIP To switch the Ti10 or TiR Imagers between a full infrared display and Picture In Picture PIP display 1 Press until Fusion appears over f
11. eeeeeneeeeseaees 20 mm EFL F 0 8 lens Thermal Sensitivity NETD MPN stats elastin ieee EA lt 0 2 C at 30 C 200 mk US N E E A E EEEE lt 0 1 C at 30 C 100 mK DE o AEA I E O TE I lt 0 1 C at 30 C 100 mK LE E E EE A I EE E TE lt 0 07 C at 30 C 70 mK Infrared Spectral Band cccceeeeeeeeeeeeeeeeeeees 7 5 um to 14 um Visual CAMELA ccccecccceeeeceeseeseeeeesneeesneeeesnaes 640 x 480 resolution Image Presentation Palettes THR and TO wesc concicectenavecesivasenecaniecoecanssinacen lronbow Blue Red High Contrast Grey TiR 1 and Ti25 sacnsmercsvavucsuiiouteceusndvadantledusenamdoas lronbow Blue Red High Contrast Level and Span Amber Hot Metal Grey Smooth Auto Scaling and Manual Scaling of level and span Minimum Span in manual mode 17 Ti10 Ti25 TiR and TiR1 Users Manual WAT E A EE AE P E AEA Meas 5 C T25 HR NG TRA senina 2 5 C Minimum span in auto mode NID O aA EENE I E 10 C 125 HR and TRI Aena ii 5 C IR Fusion Information Visual and IR Blending Ti25 and TiR1 only Picture In Picture PIP TPO ae WP aa a aucncne ndawe aves 100 IR displayed in center 320 x 240 pixels T25 and TR Taiac Three levels of on screen IR blending displayed in center 320 x 240 pixels Full Screen PIP off VITO ANG TIR Siesceteteiceaseenaubedetstartven ecnerens 100 IR displayed on 640 x 480 LCD F2 gand TR Mee easier eee ae Three levels of on screen IR blending displayed on 640
12. ey 2 Press the softkey labeled Date The date can be displayed in one of two formats MM DD YY or DD MM YY 3 Press the softkey labeled with the desired date format 4 Press the softkey labeled Up or Down to adjust the selected date element 5 Press the softkey labeled Next to move to the next date element 6 Press the softkey labeled Done when finished Setting the Time To set the time 1 Press o until Time appears over the F3 softkey 2 Press the softkey labeled Time The Imager will display time in two different formats 24 hour or 12 hour 3 Press the softkey labeled with the desired format 4 Press the softkey labeled Up or Down f to adjust the selected time element 5 Press the softkey labeled Next to move to the next time element 6 Press softkey labeled Done when finished The 12 hour format has a selection for setting whether the time is AM or PM Focusing and Capturing an Image Point the Imager at the object or area of interest focus by turning the focus control until the image displayed on the LCD 1s as clear as possible and then press and release the trigger The Imager displays the captured image and a menu The TiR and T110 menu allows image storage The TiR1 and T125 menu allow image storage image setting adjustments and recording of audio annotations To cancel image storage and return to live viewing press and release the trigger 6 Thermal Imagers Saving Imager
13. for two seconds Features and Controls Imager features and controls are shown and described in Table 2 Ti10 Ti25 TiR and TiR1 Users Manual Table 2 Features and Controls Taw SS z en O e roces OOOO Ce ieoa nna OOOO 4 Thermal Imagers Using the Menu Table 2 Features and Controls cont es oo o o oreroraa OOOO Thermal IR camera Using the Menu The menus coupled with the three softkeys and FJ provide access for setting features date time language units backlight and spot temperatures thermal image display and saving and viewing stored images To bring up the menu press f The text above each function softkey and corresponds to that softkey throughout all menu screens Press to open and cycle through the menus The menu will disappear several seconds after the last press of a softkey Changing the Displayed Language To change the display to present information in another language 1 Press 6 until the F1 softkey label reads Language 2 Press the softkey labeled Language 3 Press the softkey labeled Up or Down to move the cursor to the desired language 4 Press the softkey labeled Back Done to set the units Setting the Imager Clock The Imager has an internal real time clock that holds the date and time of day Ti10 Ti25 TiR and TiR1 Users Manual Setting the Date To set the date 1 Press until Date appears over the F1 softk
14. form the steps in the Reviewing and Deleting Stored Images section to bring the desired image to the Imager s display 2 Press the softkey labeled Select 3 Press the softkey labeled Audio 4 Press the softkey labeled Review The saved voice annotation will be replayed through the Imager s speaker Changing the Temperature Units The Imager will display temperature in Fahrenheit or Celsius To change the temperature units 1 Press f until Units is displayed over f 2 Press the softkey labeled Units 3 Press for Celsius or F for Fahrenheit 4 Press the softkey labeled Back Done to set the language Enabling Disabling Spot Indicators Ti25 and TiR1 Only To enable or disable the hot and cold spot indicators 1 Press until Spot Temp appears over f 2 Press the softkey labeled Spot Temp 3 Press the softkey labeled Off to turn the hot spot indicators off or press the softkey labeled On to turn them on 4 Press the softkey labeled Back Done to accept the setting Making Accurate Temperature Measurements All objects radiate infrared energy The amount of energy radiated is based on two primary factors the surface temperature of the object and the emissivity of 12 Thermal Imagers Setting Emissivity Ti25 and TiR1 only the object s surface The Imager detects the infrared energy from an object and uses this information to estimate the temperature of the object Most of the objects measured
15. normal aging Supported Languages cccsecceeseeeeeeeeeees English Italian German Spanish French Russian Portuguese Swedish Turkish Czech Polish Finnish Simplified Chinese Traditional Chinese Korean and Japanese 16 Detailed Specifications Temperature Measurements Thermal Imagers Detailed Specifications Temperature Range not calibrated below 10 C TR and TIRT sermen a 20 C to 100 C i EESE AO S E A et 20 C to 250 C WIZ e E EEE IE AE E ET 20 C to 350 C Accuracy TA and TIO a 5 C or 5 whichever is greater TAT and WES senean is 2 C or 2 whichever is greater Measurement Modes cccceceeseeeeeeeeeeeeeeaeees Smooth Auto Scaling and Manual Scaling On screen Emissivity Correction 000000 Ti25 and TiR1 Only Imaging Performance Field Of ViOW cccceececseseeceeseecseeeesneseeeneeeesnaaes 23 x17 Spatial Resolution IFOV cccceeessseeeeeeeees 2 5 mRad Minimum Focus Distance Thermal LONG sscstcdesnccecteesend lt eaaevcncsteneDhtesseceases 15 cm approx 6 in Visible Visual Light Lens ccceeseeeees 46 cm approx 18 in FOCUS coins as cosactgareab E costes Manual IMAGE FLEQUENCY cccsecccseceeseeseeeeseeeenseeeseees 9 Hz refresh rate Detector TYG vacascecasnasisichs sanseteemasinalennntetyenniecton 160 X 120 Focal Plane Array uncooled microbolometer Infrared LENS TyPe cccceececsesseeee
16. nvoice Buyer for importation costs of repair replacement parts when product purchased in one country is submitted for repair in another country Fluke s warranty obligation is limited at Fluke s option to refund of the purchase price free of charge repair or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period To obtain warranty service contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepaid FOB Destination If Fluke determines that failure was caused by neglect misuse contamination alteration accident or abnormal condition of operation or handling including overvoltage failures caused by use outside the product s specified rating or normal wear and tear of mechanical components Fluke will provide an estimate of repair costs and obtain authorization before commencing the work Following repair the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges FOB Shipping Point THIS WARRANTY IS BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLU
17. of the slot Note The SD Card can be inserted and removed while the Imager is in operation To insert an SD card into the Imager carefully slip the card into the slot with the card s label facing toward the LCD display Push the card in until it catches Setting the Backlight The backlight can be set to Auto sensing or Full Bright To set the backlight 1 Press 6 until Backlight appears over f 2 Press the softkey labeled Backlight 3 Press the softkey labeled Auto or Full Bright Note To extend battery life Auto Sensing automatically adjusts backlight brightness based on ambient light levels General Specifications Temperature Operating wesesccsrevacevenavinweaiensswectacersccsannatdsercneeecete 10 C to 50 C 14 F to 122 F ONS P 20 C to 50 C 4 F to 122 F without batteries Relative Humidity 0 cccceeeeeeeeeeeeeeeeeees 10 to 90 non condensing DESAY gee sa Goes cette sad egies nessa netaner seca dadescaunels 640 x 480 color LCD approx 2 X 3 Landscape orientation with Backlight selectable Bright or Auto Controls and Adjustments User selectable temperature scale C F Language selection Time Date set Emissivity selection Ti25 and TiR1 only User selectable Hot Spot and Cold Spot on the image TiR1 and Ti25 only 15 Ti10 Ti25 TiR and TiR1 Users Manual SOWA E ceio a eare tarrean e wea leavend isha SmartView full analysis and reporting software
18. red image to the display 2 Press the softkey labeled Select 3 Press the softkey labeled Delete To delete all the images from the SD card 1 Press to activate the menu 2 Press the softkey labeled Memory 3 Press the softkey labeled All Images Adding Voice Annotation to Saved Data Ti25 and TiR1 Only Voice annotation can only be added to an image prior to storing it After capturing an image the Image Capture menu appears To add a voice annotation to the image 1 Press the softkey labeled Audio 2 Press the softkey labeled Record to start the recording 3 Speak into the Imager s microphone opening Up to 60 seconds of audio can be recorded for each image 4 When done recording press the softkey labeled Review to listen to what was recorded When an audio recording has been created for an image appears in the display while the image is displayed To keep the audio annotation proceed to the next step Otherwise press the softkey labeled Append or Replace to modify the recording before storing the image Once stored the audio annotation can only be reviewed and not modified 5 Press the softkey labeled Back to return to the Audio menu 6 Press the softkey labeled Store to store the measured data and audio annotation 11 Ti10 Ti25 TiR and TiR1 Users Manual Listening to Voice Annotations Ti25 and TiR1 Only To play the voice annotation already stored with an image on the SD card 1 Per
19. ree Setting the Imager Clock snnnnnnnneeeesssssssssssseetereeessssssssssssssse SA ea D eee eee E E E S eee ere Setane the TIME sn saninsiaccnsteancnecedussvesneenscndadancanaitevosesatsanyninianane Focusing and Capturing an mage eneeeesseessssssseeeeeerrressesss Saving Imager Data cccccccccssssssssseseeeeeeeceeeeeceeaaaasesssesseeeeeeees Adjusting the Thermal mage cc cceeeeeeseeseeseeeeeeeeeeeeeeeaaes SC lCCUIN SAP AICIIC ccasezacecgossteeaantecnascacnosaaevaseeteduadessuuvsaeeeasions CUMS CCR AN GS seses ET Setting the Level Manual ccccccsssssssssssssssseeeeeeeees Setting the Temperature Span Manual cccccccee Switching Between PIP and Full IR T110 and TiR Only Setting IR Fusion and PIP Ti25 and TiR1 Only Reviewing and Deleting Stored Images cccccceeeeeeeeeeees Adding Voice Annotation to Saved Data T125 and TELON arses nat sat e sag esateaiee sale seassataaionseseaiaesecaatle Listening to Voice Annotations T125 and TiR1 Only Changing the Temperature Units ccccccsssssseseeeeeeeeeeeeeeeeeaes Enabling Disabling Spot Indicators T125 and TiR1 Only Making Accurate Temperature Measurements ccce Setting Emissivity T125 and TiR1 only eeeeeeeeeeeeeeeees CLG File POA essuie ened esei ea SmantView SOMW ale asrasin einan aa a AEE Ti10 Ti25 TiR and TiR1 Users Manual Changing the SD
20. s to set the bitmap bmp file format or F to set the infrared storage is2 file format The bitmap format only saves the image shown on the Imager s display The is2 format is a proprietary file format that saves the radiometric data fusion blend palette visual image screen settings and voice recording to annotate the stored image Bitmap bmp images can be transferred to a PC and used immediately in non proprietary software and electronic documents Images in 1s2 format can be transferred to a PC for further analysis and report generation through Fluke SmartView software or non Fluke software which is available from specially approved software vendors Visit the Fluke web site or contact Fluke to find out about currently available software options SmartView Software SmartView software is supplied with the thermal imager This software is specially designed for Fluke imagers and contains powerful functions to analyze images organize data storage and create professional reports SmartView allows audio annotations to be reviewed on a PC SmartView can be used to export IR and visible images as JPEG BMP GIF TIFF WMF EXIF or EMF formatted files 14 Thermal Imagers Changing the SD Card Changing the SD Card To eject an SD card from the Imager press in on the exposed edge of the SD card and then release The card should pop partially out after releasing it Carefully pull the card out
21. s supplied by a rechargeable Nickel Metal Hydride battery A full visual image 640 X 480 can be displayed and stored with each IR image In addition to the features mentioned above the Ti25 and TiR1 provide voice recording for annotating saved images Contacting Fluke To contact Fluke call 1 800 760 4523 in USA 1 800 363 5853 in Canada 3 1 402 675 200 in Europe 8 1 3 3434 0181 in Japan 65 738 5655 in Singapore 425 446 6888 from anywhere in the world Or visit Fluke s Web site at www fluke com To register your product visit register fluke com Ti10 Ti25 TiR and TiR1 Users Manual Safety Information Use the Imager only as specified in this manual See Table 1 for a list of symbols used on the Imager and in this manual A Warning identifies hazardous conditions and actions that could cause bodily harm or death A Caution identifies conditions and actions that could damage the Imager or cause permanent loss of data A Warning To avoid a burn hazard remember that highly reflective objects will result in lower than actual temperature measurements See Emissivity information later in this manual for more information Do not use in a manner not specified in this manual or the protection provided by the equipment may be impaired Table 1 Symbols Battery condition Battery charging Conforms to requirements of European Union and Important information See European Free Trade manual Association
22. such as painted metal wood water skin and cloth are very efficient at radiating energy and it is easy to get very accurate measurements For surfaces that are efficient at radiating energy high emissivity the emissivity factor is estimated to be 95 or 0 95 This estimate works for most purposes This simplification does not work however on shiny surfaces or unpainted metals These materials are not efficient at radiating energy and are Classified as having low emissivity To accurately measure materials with a low emissivity an emissivity correction is necessary The easiest correction method is to set the Imager to the proper emissivity value so the Imager automatically calculates the correct surface temperature If the Imager uses a fixed emissivity value meaning that it is set to one value and the user cannot adjust it then the Imager s measurement must be multiplied by a value found in a look up table to get a more accurate estimate of the actual temperature The TiR1 and T125 have the ability to set emissivity by directly entering a value or using a table of built in values The TiR and T110 have emissivity that is permanently fixed at 0 95 which works well for most surfaces but can provide very inaccurate reading if used directly on a shiny metal surface A significant amount of information is available on emissivity Further study of this topic is recommended to get the most accurate temperature measurements using the Imager
23. x 480 LCD Ti25 and TiR1 allows user to adjust palette aloha blend level span PIP and emissivity on a captured image before it is stored Voice Annotation 00ccceccceeeeeeeeeeeeeeeeeeeeeeees 60 seconds maximum recording time per image TiR1 and Ti25 only Image and Data Storage Storage MECIUM cccsecccseseeeeeeeeceeeeeeaeeeeeaeees SD Memory Card 2 GB memory card will store at least 1200 fully radiometric is2 IR and linked visual images each with 60 seconds voice annotations or 3000 basic bmp IR images Pile FOrnmal a deviates a a Non Radiometric bmp or Fully Radiometric is2 No analysis software required for Non Radiometric bmp files Export File Formats w SmartView Software JPEG JPG JPE JFIF BMP GIF DIP PNG TIF and TIFF 18

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 K550N-D  EMRF-NRF51-SKY66111 DataSheet  SW VGA-Ars Rev E.pmd  Manual de instruçőes  Pulse - Instructions Manuals  Elite EIM-506 Use and Care Manual  Kensington Aluminum Finish Case for Samsung Galaxy S® 4  Ingrédients & Valeurs nutritionnelles moyennes  TEFAL FR401531 Instruction Manual  T===Sinus 44  