Home
FIELD CONTROLS CW-HD-1 User's Manual
Contents
1. CLEARWAVE WATER CONDITIONER Model CW HD 1 The ClearWave is the most advanced hi tech computerized anti scale device available today It operates by using a programmed chip to constantly cycle through and induce over 200 different electro magnetic low frequency wave pulses into the water These wave pulses produce water with remarkable anti scale properties without adding salts or chemicals at an operating cost for electricity of approximately 5 00 US per year POWER SPECIFICATIONS 18 VAC 5 Watts 09 Amps PRODUCT QUESTIONS PHONE FIELD FIRST for answers on product maintenance operation or replacement part questions Phone 252 522 3031 pg E mail fieldtec fieldcontrols com Y FELD CONTROLS THE VENTING SOLUTIONS COMPANY Field Controls LLC 2630 Airport Road Kinston NC 28504 Phone 252 522 3031 Fax 252 522 021 4 Web www fieldcontrols com HOW IT WORKS Pure water contains nothing but H20 But water as it comes out of the ground is rich in a multitude of minerals Minerals such as calcium and magnesium are the main components of hard water and the cause of scale formation and other problems There are three basic methods used to control the problem of hardness and specifically scale formation ION EXCHANGE One method is to remove the calcium and magnesium from the water through ion exchange the traditional water softener This method requires the use of a resi
2. The ClearWave unit is guaranteed for 18 months from the date of the original purchase against defects in workmanship and material During that period these defects will be repaired or the unit will be replaced without charge at manufacturers option This guarantee covers normal consumer usage but excludes damage caused by alteration accident misuse abuse neglect installation or normal wear and tear Should your unit fail within the unit guarantee period please pack it carefully in the original box and return it to your supplier This guarantee does not affect your statutory rights Please return the warranty registration sheet on the back of this manual to register your purchase SATISFACTION GUARANTEED In the unlikely event you are not satisfied with the performance of the ClearWave Water Conditioner it should be returned with the receipt to the point of purchase complete and within 180 days of the original purchase date It should be packed in the original box and is subject to the Terms and Conditions of the manufacturers warranty For more information on the ClearWave visit the Field Controls web site at www fieldcontrols com FIELDCONTROLS THE VENTING SOLUTIONS COMPANY P N 46300500 Rev E 04 04 Page 7 ClearWave M Warranty Registration Name Address City State Zip Code Phone Fax 1 Grains if 2 ppm s if Light 3 Do you have iron present Moderate YES our If
3. housing If longer wires are needed up to 50 feet of 12Ga stranded wire can be added to the antenna wires with an insulated butt end wire connector or they can be replaced with 65 feet of 12Ga stranded wire Ana WALL OR PIPE MOUNTING Wi wenes ie BRACKET For pipe mounting Bend back and forth until tab breaks off a V V e CLEARWAVE JS o i Main Cold CS Water Supply TNL Hold area with pliers Coiled Anti Clockwise Coiled Clockwise SIDE VIEW Start wrapping under Start wrapping 3 bottom of pipe Power if over top of pipe Figure 2 Supply Jack Each coil of the antenna wire should be tightly wrapped around the pipe and pressed sungly against the Power ER J adjacent coil Supply lt 18 Ga thermostat wire up to 200 feet Figure 1 Page 4 PROPERLY WRAPPING THE ANTENNAE The antenna wrap around the water pipe on each end of the ClearWave see Figure 1 A minimum of seven fully wrapped coils of the antenna wire with each coil wrapped tightly against the pipe and pressed snugly against each other is required for best results see Figure 3 The operation of the ClearWave and the antenna installation is not based on direction of water flow but one antenna MUST be wrapped in a clockwise direction and the other wrapped in a anti clockwise direction WIRE TIE ATEND OF COIL 1 First wrap the antenna onto the water pipe by securing the right antenna to the water pipe next to the ClearWave housing wi
4. Install the ClearWave at least ten feet from any radio television or cordless telephone base unit to eliminate possible interference MAXIMUM WATER CONDITIONING CAPACITY FOR NOMINAL PIPE DIAMETERS Nominal Pipe 3 ES n H Blameter 1 2 3 4 1 1 1 4 1 1 2 of Units Req 1 1 1 2 2 GPM Flow 7 16 28 45 61 Page 5 OPERATION TIMETABLE FOR THE CLEARWAVE The following timetable of events should be used to evaluate the operation of the ClearWave during the 180 day customer satisfaction period This is the best way to evaluate the ClearWave operation and benefits the ClearWave technology can provide for you and your home Please note testing for changes in hardness with current testing practices will not show you if the ClearWave is working The current practice of determining water hardness is the measurement of the concentration of calcium and magnesium in the water Since the ClearWave does not remove any calcium or magnesium ions from the water testing the water before and after the installation of the ClearWave will not show any change DAY Tea The ClearWave action immediately starts to loosen existing scale in both the hot and cold water systems One should find soap lathers more easily DAY 5 and onwards Scale begins to break down and come off water heater elements immersion heaters and tanks Most particles are microscopic and will flow through your water system but some
5. Yes circle one Heavy y NO Very Heavy 4 Had you installed an Iron rs T prior to purchasing NO pone Kriowi ClearWave 5 Where did you purchase ClearWav from 6 Date 7 Mfg date ae ae Y Briefly describe any current water One problems scale build up odor taste Light staining etc 1 3 grains 17 51 Moderate 4 6 grains 52 102 Hard 7 10 103 170 ppm Very 10 grains above 170 ppm above ppm Parts Per Million Page 8
6. electrostatic approach was an improvement upon the bar magnets and electromagnets but increased the initial cost considerably while not dramatically improving the range of effective conditions ClearWave The ClearWave water conditioning system operates on similar principles as the magnets and electrostatic devices But unlike those previously mentioned the ClearWave uses microprocessor technology to electronically generate inaudible wave forms which help keep calcium carbonate particles scale dissolved or suspended in water With ClearWave the electric field generated is always being applied to the water while a magnetic field relies on the movement of water to produce the electric potential changes Page 2 Low frequency waveforms are emitted through two coiled wires attached to the outside of the water pipe As a result of these waveforms the two coils are constantly inducing a voltage into the water in the area of the ClearWave When one coil induces a positive voltage the other coil induces a counteracting negative voltage This electric field causes the calcium or magnesium to remain in solution or suspension and the treated water continues to dissolve scale as it flows downstream Over time the ClearWave treated water helps solve hard water problems in the entire system including pipes water heaters showerheads and appliances The ClearWave is the state of the art in electronic water conditioning The ClearWave
7. ess level the ClearWave will effectively work on is 425 ppm or 25 gpg Above these levels the ClearWave should be used in conjunction with a tradition ion exchange water softener to remove hardness and condition the water This allows you to minimize the salt used to remove the hardness and maintain the cost saving benefits of the ClearWave water conditioning system Page 3 INSTALLATION WHERE TO INSTALL THE CLEARWAVE 1 For domestic water applications locate where the main water supply pipe enters the home or building For light commercial applications such as dishwashers ice makers boilers water heaters etc attach the ClearWave unit to the water supply line to that particular appliance Find a suitable location to install the ClearWave on the water supply pipe before the piping branches off to supply water throughout the home HOW TO INSTALL THE CLEARWAVE 1 One set of mounting brackets are provided for mounting the ClearWave onto 1 2 to 1 1 2 water pipes or wall mounted near the selected pipe area Mount the mounting brackets to the base of the ClearWave by using the screws provided Mount the ClearWave onto the pipe with wire ties or to the wall with appropriate fasteners see Figure 1 For pipe mounting the wall mount tabs should be removed from the mounting brackets see Figure 2 2 Plug the antenna into each end of the
8. microprocessor controlled technology continually varies its frequency affecting the widest range of mineral concentrations and other variables that cause hard water problems The length of time required to alter the characteristics of the lime scale is dependent on the mineral makeup of the water being treated The mineral makeup of the water can impact the operation of the ClearWave s electrical field A high concentration of iron soluble and insoluble causes a disruption and weakening of the electrical field reducing the effectiveness on scale reduction Under these conditions an iron removal system is required to filter out the iron prior the ClearWave Additionally if the water is excessively hard greater than 25 grains the ClearWave is often less effective TESTING FOR HARDNESS AND IRON LEVELS High Iron Concentration A high concentration of iron soluble and insoluble causes a disruption and weakening of the ClearWave s electrical field reducing its effectiveness on scale reduction Under these conditions an iron removal system is required to filter out the iron prior to the ClearWave We recommend an iron removal system for total iron levels above 0 3 ppm parts per million Contact your local health department or water authorities for testing your water Water Hardness On hardness levels above 250 ppm or 15 gpg two ClearWave units should be mounted in series on the incoming water pipe The maximum hardn
9. n filled tank with a high concentration of salt ions As the water flows through the resin tank the salt ions typically sodium are exchanged for the calcium or magnesium ions This lowers the concentration of the minerals that cause scale and therefore inhibits scale formation CHEMICAL ADDITION A second method used to control hard water scale is the addition of chemicals such as phosphates to the water These materials chemically alter the scaling characteristics of the calcium or magnesium allowing the concentration of the minerals to stay the same while still reducing scale formation and its affects Both of the above methods require the use of consumable materials to change the makeup of the water For these devices to function properly the homeowner must continuously replenish the salts or chemicals as well as perform periodic maintenance on the equipment In addition to these inconveniences the chemicals and salts discharged into the effluent water present problems downstream to the municipal water treatment facility and the environment Many U S cities have been enacting and or evaluating environmental legislation to limit or reduce the levels of chemicals or salts that result from these types of water treatment methods ELECTRIC POTENTIAL A third method used to treat the hard water problems associated with scale utilizes changes in electrical potential in the water to produce the affects of chemical addition The electric potential a
10. pplied changes the scaling characteristics of the calcium or magnesium without the removal of these ions or the addition of chemicals Magnets Bar magnets were the first types of equipment used to generate electric potential changes in water Bar magnets have been used with limited success to inhibit scale formation The fixed magnetic field of a bar magnet creates electric potential changes in the water only when the water moves through the magnetic field Electromagnets function in much the same way as bar magnets but the magnetic field is created by passing a current through a coil essentially creating a more powerful fixed magnetic field Inherently fixed magnetic fields are limited to a narrow range of applications pipe sizes and water flow rates Permanent bar magnets and electromagnets have been promoted as a method of treating hard water but they do not treat the vast and complex array of mineral contents and concentrations found in water Particles can also build up inside the pipe where the magnet is placed eventually causing blockage at the very point it is supposed to be doing its job Electrostatic Devices Electrostatic devices create an electric potential in the water between two electrodes One electrode is mounted in the water stream in the center of the pipe housing while the pipe itself acts as the other electrode The device applies a voltage across the two electrodes to create the electric potential in the water This
11. small particles may be seen in the water coming from the hot water tap DAY 10 to T6 It should be noticeably easier to wipe clean ceramic plastic glass and metal surfaces By now the quantity of bath soap dish soap laundry detergent and laundry softening agents can be reduced Scale should have loosened on taps showerheads and frequently used appliances that boil water such as coffee makers DAY 16 and onwards Scale should continue to loosen from taps showerheads and pipes With the continuing break down and reduction of scale from the heating surfaces of water heaters water should heat up quicker using less energy to achieve the desired temperature After 1 to 2 months Any scaly crust or stains in toilets or under taps should be significantly reduced No new stains or crust should form Mold that attaches to scale will begin to disappear from shower curtains and once cleaned should not reappear Depending on the water hardness in the area the full effects can take up to 12 weeks especially if the system has been heavily scaled up over many years NOTES l If iron is present in the water supply use an iron filter prior to the ClearWave M 2 Depending on water hardness or water make up two CW HD 1 units may be required The CW HD 1 can be used on water up to 25 grains of hardness If over 25 grains it can be used to aid the operation of a water softener MANUFACTURERS WARRANTY
12. th a wire tie Wrap the right antenna clockwise over the top of the pipe first keeping the antenna wire tight against the pipe and the preceding coil Secure the end of the right antenna wire to the water pipe with a wire tie see Figure 3 OF COIL Figure 3 2 Wrap the left antenna onto the water pipe by securing the antenna to the water pipe next to the ClearWave housing with a wire tie Wrap the left antenna counter clockwise Under the bottom of the pipe first keeping the antenna wire tight against the pipe and the preceding coil Secure the end of the left antenna wire to the water pipe with a wire tie 3 When energized the ClearWave modulation indicator lights start flashing sequentially indicating that the ClearWave is functioning properly If the indicator lights do not flash sequentially unplug the power supply wait one minute then plug in the power supply again If at any time a functional problem is suspected unplug the power supply wait one minute then plug in the power supply again NOTE The performance of the ClearWave is not affected by the direction or orientation of the unit The unit may be mounted to horizontal vertical or diagonally The ClearWave can be used effectively on any type of water pipe galvanized copper or plastic NOTE The ClearWave is designed and tested to cause little or no interference to other communication devices such as televisions and most cordless telephones