Home

FCI Home Appliances ECCB 30" User's Manual

image

Contents

1. SEE NOTE FROM EDGE OF CUTOUT SLOT FOR R AND FRONT EDGE OF CABLE 1 1 2 3 8 cm COUNTERTOP ROUTING MIN CLEARANCE 2 1 2 6 35 cm 3 1 2 9 cm 2 1 2 6 5 cm INST 035 2 WALL COVERING CABINETS AND COUNTERTOP MUST WITHSTAND HEAT UP TO 93 C 200 F INST 023 2 Figure 3 Cutout dimensions and requirements HOME APPLIANCES Installation Manual Models ECCB TCCB 30 36 ENGLISH Under the cooktop it is necessary to install a partition spaced at least 15 mm from the bottom of the appliance as shown in figure 3 If an oven or another appliance is built in under the cooktop this partition isn t necessary but in any case keep this clearance CUTOUT WIDTH A B C D E F G ae Fa d 18 45 7 cm 30 76 2 cm 30 4 cm 0 cm min min 2 5 cm min n h 30 M 13 33 cm 76 2cm 29 19 5 8 76 2 cm min Height from see note Clearance from a of I 73 7 cm 49 8 cm countertopto Clearance from cutout to side Un UNT 33 7 8 19 1 4 nearest countertop to wall on the left Hs ead 36 86 cm 49 0 cm 36 cabinet on unprotected and right of the cabinets 91 4 cm 34 9 16 19 5 8 91 4 cm min either side of overhead Unit 87 8 cm 49 8 cm unit surface IMPORTANT NOTE 24 61 cm min clearance if bottom of wood or metal cabinets is protected by not less than 1 4 0 6 cm flame retardant millboard covered with no less than No 28 MSG
2. Si les bords ne sont pas lisses l int rieur des coins n est pas arrondi et l encastrement a t forc il est possible que le contre plaqu du plan de travail se fendille Cette table de cuissons a t concue avec de grande tol rance de d coupe pour couvrir le replacement possible avec d autres marques Quelques d coupes pour des remplacements possibles Dim Inches cm e 30 29 x 19 5 8 73 7 x 49 8 e 36 34 9 16 x 19 5 8 87 8 x 49 8 f Manuel d installation MA Mod les ECCB TCCB 30 36 BENNE Installation de la Table de Cuisson AVERTISSEMENT e Risque du fait du poids excessif Soyez deux personnes ou plus pour porter et installer la table de cuisson Sinon vous risquez de vous blesser au dos ou de subir d autres blessures e Risque de coupure M fiez vous des bords tranchants et des extr mit s du polystyr ne lorsque vous portez le produit Sinon vous risquez de vous couper ou de vous faire l g rement mal e Toujours consulter le fabricant du plan de travail pour les instructions sp cifiques e Bien v rifier que le plan de travail est carr et niveau et assurez vous qu aucun l ment de structure n interf re avec les exigences d espace e Pr parez la d coupe selon les instructions voir Figure 4 Les outils dont vous aurez besoin dimensions d coupe e Bien v rifier que les l ments suspendus le plan de t
3. doit tre dans un endroit qui permette que le conduit pour l entretien ait suffisamment de jeu INST 030 3 Important e Pour les installations de mat riau solide comme le Surei et le Corian consultez le fabricant de surface solide Appliquez du ruban thermo r fl chissant comme le Scotch feuille de ruban aluminium 425 ou 427 autour de la d coupe de sorte qu il d borde et se replie sur le dessus et les c t s e N enveloppez pas le ruban en dessous de la table de cuisson V rifiez bien que le ruban aille au del du rebord le plus externe de la table de cuisson Tous les angles doivent tre recouverts par du ruban 23 Manuel d Installation Mod les ECCB TCCB 30 36 TIME e HOME APPLIANCES Connexions Electriques Ne le branchez pas un tuyau gaz Ne placez de fusible dans le branchement ou de circuit neutre Raccordez les deux lignes d alimentation phase pancen D branchez l lectricit avant de mettre en service le produit Sinon vous risquez de vous tuer ou de vous lectrocuter AVERTISSEMENT Une connexion incorrecte de l installation lectri que en aluminium au cuivre peut entra ner des probl mes graves Taille mi Alimentation a Umum requise de c ble q requise TCCB 33052 TCCB 33053 TCCB 33066 TCCB 33067 240V 28A No ECCB 33050 60 Hz 10AWG ECCB 33051 ECCB 33070 ECCB 33071 TCCB 3365
4. travail au Du plan de la paroi meubles non 33 7 8 19 1 4 mne ble l plus travail la lat rale sur la jprot6a amp es la 36 86 cm 49 0 cm 36 Me gun duas surface non gauche et la E 91 4 cm 34 9 16 19 5 8 91 4 cm min cot s de prot g e la droite de 87 8 cm 49 8 cm l appareil verticale l appareil IMPORTANT NOTE En dessous de la table de cuisson il est n cessaire d installer une cloison espac e d au moins 15 mm du fond de l appareil comme indiqu sur la figure 3 Si un four ou un autre appareil lectrodomestique est int gr sous la table de cuisson cette cloison n est pas n cessaire mais dans tous les cas conservez la distance indiqu e 24 61 cm espace min si le bas des meubles en bois ou en m tal est prot g e par au moins 1 4 0 6 cm de carton reliure ignifuge avec une t le d acier inoxydable No 28 MSG d au moins 0 015 0 04 cm ou d aluminium 0 024 0 06 cm ou de cuivre 0 020 0 05cm 30 76 2 cm d espace min entre le haut de la plate forme de cuisson et le bas du meuble non prot g en bois ou m tal Conseils importants de pr paration 1 2 Biseautez tous les bords expos s du contre plaqu d coratif pour emp cher qu ils ne s caillent Arrondissez les quatre coins de la d coupe et limez le pourtour pour que les bords soient lisses et que les coins ne se fissurent pas Utilisez une m che de 1 4 ou 3 8 pour percer les trous chaque angle
5. 4 cm min cercano en ambos superficie no l proteg 87 8 cm 49 8 cm lados de la placa protegida IMPORTANTE NOTE Es necesario instalar bajo la encimera un panel de separaci n a una distancia de al menos 15 mm del fondo del aparato como se muestra en la figura 3 Si debajo del aparato se instala un horno u otro electrodom stico no hace falta colocar el panel de separaci n pero s mantener la distancia se alada La distancia m nima podr ser de 61 cm si la base de madera o metal del armario est protegida como m nimo por 0 6 cm de cart n grueso resistente al fuego cubierto por una l mina de acero inoxidable de 28 MSG m n 0 04 cm o de aluminio 0 06 cm o de cobre 0 05 cm Si la base del armario es de madera o metal sin protecci n la distancia entre esta y la encimera ser de 76 2 cm Importantes Consejos de Preparaci n 1 Bisele todos los bordes expuestos de laminado Esta placa de cocci n ha sido dise ada para decorativo para evitar que se astille 2 Redondee las esquinas recortadas y lijelas los bordes deben quedar suaves para evitar que se resquebrajen las esquinas Se recomienda utilizar un taladro con una broca de di metro de 1 4 o 3 8 en cada esquina adaptarse a unas dimensiones de encastre est ndar que permitan sustituirla con placas de otras marcas Recomendamos que considere la dimensi n m nima de encastre en caso de efectuar una nueva instalaci n Algunas dimensiones de en
6. Cleveland OH 44131 5575 To eliminate the risk of burns by reaching over heated surface units cabinet storage space located above the surface units should be avoided If he cabinet storage is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 12 7 cm beyond the bottom of cabinet Cooktop Installed over Oven Installation Only certain specified cooktop and oven models are approved for cooktop over oven installations Cooktops approved for this type of installation will have an approval label located on the outside of the burner box If you do not find this label contact your dealer to confirm that cooktop is approved The label on the bottom of your cooktop lists the cooktop and oven combinations that are approved for this type of installation Refer to oven manufacturer s Installation Instructions for approval for built under use and proper cut out dimensions 1 1 2 4 cm min f Installation Manual Qy Models ECCB TCCB 30 36 EE Product Dimensions and Cutout Requirements TOUCH CONTROL 30 76 2 cm 36 91 4 cm INST 034 ENERGY REGULATOR 21 36 91 4 cm 21 53 3 cm 30 76 2 cm 53 3 cm ES 21 53 3 cm 21 53 3 cm INST 033 Figure 2 Energy regulator f Installation Manual 93 Models ECCB TCCB 30 36 ET CUTOUT DIMENSIONS LENGTH OF CUT LENGTH OF CUT A B
7. debidamente prote gido conforme al c digo local de la NFPA n 70 La unidad debe conectarse adecuadamente a una toma de tierra de acuerdo con los c digos locales La tabla que encontrar a continuaci n recoge las recomen daciones m nimas de protecci n del circuito y el cali bre del cableado si el electrodom stico es la nica unidad del circuito Si utiliza un calibre de cableado menor la eficiencia de la unidad se ver a reducida y podr a provocar un riesgo de incendio Es recomen dable que la conexi n del cableado y del electrodo m stico sean efectuadas por un electricista cualifica do HOME APPLIANCES Minimos recomendados Protecci n del circuito en ampe re Calibre del cable AWG Aseg rese de que un t cnico cualificado instale y conecte a tierra correctamente su aparato Con sulte con su vendedor para que le recomiende un t cnico cualificado o un servicio de mantenimien to autorizado Esta placa de cocci n no requiere conexi n del neutro Si va a colocar la placa en un armario aseg rese de que en l hay una abertura para pasar el cable de alimentaci n Efect e la conexi n el ctrica siguiendo los pasos adecua dos para su instalaci n Este aparato est fabricado con un hilo verde de tierra conectado al bastidor de la placa de cocci n Despu s de haberse asegurado de que la corriente est desco nectada conecte el conducto flexible desde la placa de cocci n hasta la caja de emp
8. feet long 100 cm located at the right rear of the cooktop bottom box should be connected directly to junction box Do not cut the conduit A U L or CSA listed conduit connector must be provided at each end of the power 12 supply cable at the cooktop and at the junction box A time delay fuse or circuit breaker is recommended Do not ground to a gas pipe Do not have a fuse in the grounding or neutral circuit Fuse both supply phase lines A WARNING Improper connection of aluminum house wiring to the copper leads can result in a serious problem supply wire TCCB 33052 TCCB 33053 TCCB 33066 TCCB 33067 67 kW 240V 28A No ECCB 33050 60 Hz 10AWG ECCB 33051 ECCB 33070 ECCB 33071 TCCB 33656 TCCB 33657 76kW 240V 32A No TCCB 33668 60 Hz 10AWG TCCB 33669 ECCB 33654 ECCB 33655 94KW 240 V 39A No ECCB 33674 60 Hz 10AWG ECCB 33675 Digits identifying color cooktop National Fire Protection Association Batter march Park Quincy Massachusetts 02269 A three wire single phase 240 volt 60 cycle electrical system properly circuit protected to meet Local Codes of NFPA No 70 must be provided Unit must be properly grounded in accordance with local wiring code The chart below recommends the minimum circuit protector and wire size if the appliance is the only unit on the circuit If smaller sizes of wire are used the unit efficiency will be r
9. r f rence future AVERTISSEMENT La non observation des instructions contenues dans ce manuel peut entra ner la mort ou des blessures s rieuses du fait d un incendie ou d une explosion Ne pas stocker ou utiliser de l essence ou d autres liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager HOME APPLIANCES Manuel d Installation AVERTISSEMENT Avertissement Sp ciaux Veuillez lire les instructions avant toute utilisation Mod les ECCB TCCB 30 36 Lie NE II est de votre responsabilit d installer l appareil correctement Confiez l installation de cette table de cuisson un technicien qualifi Important e Respecter les r glements et ordonnances en vigueur e Avant d installer la table de cuisson veuillez noter les num ros de mod le et de s rie Ces deux num ros se trouvent sur la plaquette signal tique situ e en dessous de la caisse de la table de cuisson Avant de Proc der l Installation AVERTISSEMENT La responsabilit revient au client de contacter un lectricien installateur qualifi Veuillez vous assurer que l installation lectrique est ad quate et conforme la r glementation lectrique nationale ANSI NFPA 70 derni re dition ou normes CSA C22 1 94 r glementation lectrique canadienne partie No 0 M91 derni re dition k k k et tous les r glements et ordonnances locaux Copies des norme
10. 6 TCCB 33657 y 240V 32A No TCCB 33668 60 Hz 10AWG TCCB 33669 ECCB 33654 ECCB 33655 y yy 240V 39A No ECCB 33674 60 Hz 10AWG ECCB 33675 Informations g n rales Cette table de cuisson n exige pas de branchement neutre Si la table de cuisson doit tre compl tement ferm e dans un meuble alimentez le c ble de la table de cuisson travers l ouverture du meuble Faites les branchements lectriques selon les tapes appro pri es pour votre installation Votre table de cuisson doit tre connect au voltage lectrique correct et au fr quence sp cifi droite WALLALLU YT Figure 13 Num ro de s rie Connexion uniquement avec un cable en cuivre Si la maison est pourvue d un cablage aluminium sui vez la proc dure suivante Chiffres identifiants la couleur de la table de cuisson 1 Raccordez le cablage aluminium au cable en cui vre en utilisant des raccords sp ciaux con us et venant de Underwriters Laboratories listed pour joindre le cuivre l aluminium Suivez les instruc tions recommand es du fabricant des raccords lectriques 2 La connexion aluminium cuivre doit tre conforme aux codes locaux et industriels accept s pour les c blages Le conduit flexible conduit fourni de 3 pieds 100 cm National Fire Protection Association Batter march Park Quincy Massachusetts 02269 Il faut avoir une prise trois fils courant monophas syst me lect
11. ES ROJOS CAJA DE EMPALME CABLES DESPROTEGIDOS Uy S OVERDES CABLEADO PS DE LA PLACA 3 CABLES CABLES NEGROS CONECTOR APROBADO POR UL O CSA Si los c digos locales no permiten la conexi n del conductor de tierra al cable neutro blanco de la caja de empalme no aplicable a instalaciones canadienses INST 031 4 Figura 14 Circuito de conexi n de 4 hilos Tome como referencia la figura 15 1 Conecte el cable verde de tierra desde la placa de cocci n al cable de tierra en la caja de empalmes cable de color carne o verde 2 Conecte los conectores rojo y negro desde el pla ca de cocci n hasta los conectores correspon dientes en la caja de empalme 3 Conecte el cable blanco desde la placa de coc ci n al cable de neutro gris o blanco en la caja de empalme 4 Conecte y a sle el cable neutro gris o blanco a la caja de empalme CABLEADO DE LA PLACA CABLES ROJOS 3 CABLES CAJA DE EMPALME CONECTOR TWIST ON CABLES NEGROS CONECTOR APROBADO POR UL O CSA 3 CABLES INST 032 4 Figura 15 37 e HOME y APPLIANCES Manual de Instalaci n Modelos ECCB TCCB 30 36 EST Notas 38 APPLIANCES FCI Home Appliances LLC 2340 s Arlington Heights Rd Suite 420 Arlington Heights IL 60005 09FX1840 01 07
12. Instalaci n Modelos ECCB TCCB 30 36 JJZ Paso 5 Inserte la placa de cocci n bien centrada en el hueco de encastre Aseg rese de que el borde frontal de la encimera est paralelo a la placa Compruebe que una vez instalada la placa respeta las distancias de seguridad INST 028 Figura 9 Paso 6 Afloje los tornillos gire las grapas de fijaci n hasta que sobresalgan del borde de la caja de la placa y apriete los tornillos hasta que queden bien asegurados Figura 10 Manual de Instalacion Modelos ECCB TCCB 30 36 FS HOME APPLIANCES MUESTRA LA UBICACI N DE LA CINTA DE ALUMINIO ABERTURA CABLEADO EL CTRICO A 12 30 5 cm DISTANCIA M NIMA DESDE LA BASE DE LA ENCIMERA AL ARMARIO ADYACENTE LADO DERECHO CUBRA LA PARTE SUPERIOR Y LOS LATERALES DE LA ZONA RECORTADA INSTALE LA CAJA DE EMPALMES DE FORMA QUE SEA ACCESIBLE DESDE EL FRONTAL DEL ARMARIO INSTALACI N EN ENCIMERAS DE SUPERFICIE S LIDA INST 005 4 Figura 12 UW VU ADVERTENCIA EL CONDUCTO TIENE 100 CM DE LONGITUD INST 030 4 Para garantizar un buen mantenimiento del Figura 11 conducto este no debe estar tirante la ubicaci n de la caja de empalme debe darle una cierta holgura Importante e Para efectuar instalaciones en encimeras con superficie s lida como Surei y Corian consulte con el fabricante de la encimera Aplique cintas adhesivas de gran resistencia al calor como la cinta de A
13. Manuel d Installation Mod les ECCB TCCB 30 36 RME Notes 26 HOME APPLIANCES Tabela de Contenido Pagina Advertencias Especiales 28 Dimensiones del Producto y de Encastre 29 Importantes Consejos de Preparaci n 31 Instalaci n de la Placa de Cocci n 32 Conexiones El ctricas 36 Informaciones generales sse 36 Circuito de conexi n de 3 hilos 37 Circuito de conexi n de 4 hilos 37 Manual de Instalaci n Modelos ECCB TCCB 30 367 ZJZ Preste la debida atenci n a los siguientes s mbolos que encontrar en el manual A Pevicro Si no sigue estas instrucciones de forma INMEDIATA puede correr peligro de muerte o de resultar gravemente herido A ADVERTENCIA e Este es el s mbolo de los avisos relacionados con la seguridad alerta sobre potenciales peligros que pueden derivar en muerte o da os a las personas Si no sigue estas instrucciones puede correr peligro de muerte o de resultar gravemente herido LEA Y CONSERVE ESTAS INSTRUCCIONES Instalador Deje las instrucciones con el electrodom stico Cliente Conserve las instrucciones como referencia futura ADVERTENCIA La inobservancia d
14. NSTRUCTIONS To installer Leave these instructions with the appliance To customer Retain these instructions for future reference A WARNING If the information in this manual is not followed exactly a fire or explosion may result in personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance HOME APPLIANCES Installation Manual Models ECCB TCCB 30 36 zie Bia WARNING Special Warnings Please read all instructions before using this appliance Proper installation is your responsibility Have a qualified technician install this cooktop Important e Observe all governing codes and ordinances e Write down the model and serial numbers before installing the cook top Both numbers are on the serial rating plate located on bottom of cooktop box Before Starting Installation A WARNING It is the customer s responsibility to contact a qualified electrical installer To assure that the electrical installation is Adequate and in conformity with national electrical code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code part No 0 M91 latest edition and all local codes and ordinances Copies of the standards listed may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Rd
15. OP TWIST ON CONNECTOR BLACK WIRES U L OR CSA LISTED CONDUIT CONNECTOR INST 032 2 Figure 15 e HOME y APPLIANCES Installation Manual Models ECCB TCCB 30 36 ENGLISH Notes HOME APPLIANCES Tables des matieres Page Avertissement Sp ciaux 16 Dimensions du Produit et D coupe 17 Conseils importants de pr paration 19 Installation de la Table de Cuisson 20 Connexions Electriques 24 Informations g n rales 24 Connexion 3 25 Connexion 4 fils 25 Manuel d Installation Mod les ECCB TCCB 30 g 36 ET Veuillez pr ter attention ces symboles que vous rencontrerez dans ce manuel di Dancer Si vous ne suivez pas IMMEDIATEMENT ces instructions vous courez le risque de mourir ou d tre s rieusement bless AVERTISSEMENT e Ce symbole signifie que la s curit est en danger Il signale les risques potentiels qui peuvent entra ner la mort ou des blessures l op rateur ou aux autres Si vous ne suivez pas ces instructions la lettre vous courez le risque de mourir ou d tre s rieusement bless BIEN LIRE CES INSTRUCTIONS ET LES CONSERVER l installateur Laissez ces instructions avec l appareil Au client Gardez ces instructions comme
16. alme usando un conector de conducto que figure en la lista U L Las figuras 14 y 15 que aparecen debajo muestran las maneras m s co munes para conectar la placa de cocci n Las disposi ciones y las normas locales de su zona por su puesto tienen precedencia con respecto a estas instrucciones Complete las conexiones el ctricas en conformidad con las normas y disposiciones locales penicno Riesgo de electrocuci n marco conectado a tierra al neutro del aparato por medio de un enlace La puesta a tierra por medio de un conductor neutro est prohibida para las instalaciones de nuevos circui tos de conexi n 1996 NEC casas m viles veh cu los recreativos o en reas en donde las normas loca les proh ben la conexi n a tierra mediante un conduc tor de neutro Circuito de conexi n de 3 hilos Tome como referencia la figura 14 en la que las nor mas locales permiten conectar el hilo de toma de tie rra desde la placa de cocci n hasta el hilo de neutro del circuito hilos de color gris o blanco 1 Silas normas locales lo permiten conecte el ca ble cable lo verde de tierra desde la placa de coc ci n y el cable de neutro del circuito de conexi n hilos de color gris o blanco 2 Conecte los conductores rojo y negro desde la placa de cocci n hasta los conductores corres pondientes en la caja d empalme Manual de Instalaci n Modelos ECCB TCCB 30 36 SZ CABLEADO DE LA PLACA 8 CABLES CABL
17. castre para una eventual 3 Los bordes speros las esquinas interiores que no sustituci n han sido redondeadas y forzar el acoplamiento de la placa pueden contribuir a resquebrajar el Dim Inches ema laminado de la encimera e 30 29 x 19 5 8 73 7 x 49 8 e 36 34 9 16 x 19 5 8 87 8 x 49 8 31 f Manual de Instalaci n 93 Modelos ECCB TCCB 30 36 ZM Instalaci n de la Placa de Cocci n ADVERTENCIA e Peso excesivo La placa de cocci n debe ser transportada e instalada por dos o m s personas Si lo hiciera una sola persona podr a sufrir da os y lesiones en la espalda o en otras partes e Peligro de corte Tenga cuidado con los bordes afilados Utilice los complementos de poliestireno para trasladar el producto Si no se presta atenci n las personas que lleven a cabo la instalaci n podr an resultar heridas e Consulte siempre con el fabricante de la encimera que le dar instrucciones espec ficas e Aseg rese de que la encimera est bien equilibrada y de que ning n elemento interfiera o limite las condiciones de espacio e Prepare los cortes de la encimera de acuerdo con Figura 4 Herramientas necesarias las instrucciones vea Dimensiones de encastre e Aseg rese de que el revestimiento de la pared la encimera y los armarios que rodeen la placa de cocci n sean resistentes al calor hasta 200 F 93 C 32 f Man
18. de fixation comme indiqu sur l avant et l arri re de la caisse ensuite tournez les fixations pour qu elles ne d passent pas au del de l angle du bas du caisson des foyers Serrez les vis juste assez pour tenir en place les fixations lorsque la table de cuisson est mise dans la d coupe SUPPORTS DE FIXATION INST 027 3 Figure 8 22 Manuel d Installation Mod les ECCB TCCB 30 36 abiens tape 5 Ins rez la table de cuisson centre de l ouverture de la d coupe V rifiez que le bord avant du plan de travail est parall le la table de cuisson Faites la derni re v rification que vous avez laiss tous les espaces n cessaires INST 028 Figure 9 tape 6 Serrez les vis tournez les fixations pour qu elles d passent au del des angles du caisson des foyers Serrez bien les vis Figure 10 f Manuel d Installation Mod les ECCB TCCB 30 36 gates HOME APPLIANCES INDIQUE LES EMPLACEMENTS DU RUBAN ADHESIF ALUMINIUM REFLECHISSANT OUVERTURE DES LIGNES LECTRIQUES A 12 80 5 cm MIN ENTRE LE BAS DU PLAN DE TRAVAIL ET LE MEUBLE CONTIGU C T DROIT COLLEZ SUR LE HAUT ET LES C T S VERTICAUX DE LA D COUPE INSTALLEZ LA BO TE DE JONCTION AFIN UE L ON PUISSE L ATTEINDRE PAR LE DEVANT Figure 12 DU MEUBLE PE INSTALLATION SUR UN PLAN DE TRAVAIL SURFACE SOLIDE INST 005 3 AVERTISSEMENT LE CONDUIT A UNE LONGUEUR DE 3 PIEDS Figure 11 la bo te de jonction
19. e las indicaciones recogidas en este manual puede derivar en muerte o en da os a las personas No almacene ni utilice gasolina u otros vapores o l quidos inflamables cerca de este ni otro electrodom stico 27 HOME APPLIANCES Manual de Instalaci n Modelos ECCB TCCB 30 36 SZ ADVERTENCIAS Advertencias Especiales Por favor lea todas las instrucciones antes de utilizar este aparato Efectuar una instalaci n adecuada es responsabilidad suya Aseg rese de que el electrodom stico es instalado por un t cnico cualificado Importante e Cumpla todas las normativas y ordenanzas vigentes aplicables e Anote el n mero de serie y de modelo de la placa de cocci n antes de instalarla Ambos n meros se encuentran en la placa de serie de la base del electrodom stico Antes de comenzar la instalaci n ADVERTENCIA Contactar con un instalador el ctrico cualificado es responsabilidad suya Debe asegurarse de que la instalaci n el ctrica es adecuada y conforme con el c digo el ctrico nacional ANSI NFPA 70 ltima edici n o con las normativas C22 1 94 o con el C digo el ctrico canadiense Canadian Electrical Code secci n 0 M91 ltima edici n y con todos los c digos y ordenanzas locales Puede obtener copias de las normas citadas en National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Va
20. ecific instructions e Ensure the countertop is square and level and ensure no structural members interfere with space requirements e Prepare the cut out according to the instructions see cut out dimensions I e Make sure the wall coverings countertop and Figure 4 Tools you will need cabinets around the cooktop can withstand heat up to 200 F 93 C HOME APPLIANCES Step 1 Remove packaging materials and literature package from the cooktop before beginning installation Remove Installation Manual from literature pack and read them carefully before you begin TOP CARDBOARD MANUAL lt gt GASKET SCRAPER lt gt TOP PACKAGING BOTTOM gt y PACKAGING CARDBOARD 024 2 Figure 5 Parts Installation Manual Models ECCB TCCB 30 36 NET Step 2 Place a towel or table cloth onto the counter top Lay the cooktop upside down onto the protected surface BURNER BOX TABLE CLOTH INST 025 2 Figure 6 Step 3 A foam tape is provided to seal the cooktop edges to the countertop Apply tape approximately 1 16 1 5 mm from the glass edge to the underside of the cooktop glass Use tape around the entire glass perimeter Cut off excess where tape ends butt BURNER BOX FOAM TAPE SEAL COOKTOP GLASS INST 026 2 Figure 7 n Installation Manual 93 Models ECCB TCCB 30 36 ET Step 4 Step 6 Four clamp brackets are provided to clamp the Loosen the screws
21. educed and a fire hazard may be created It is advisable that the electrical wiring and hookup be accomplished by a competent electrician HOME APPLIANCES Recommended Minimum kW Rating on Circuit protection Wire size serial plate in amperes AWG 4 9 6 9 7 0 9 9 T Be sure your appliance is properly installed and grounded by a qualified technician Ask your dealer to recommend a qualified technician or an authorized repair service This cooktop does not require a neutral connection If the cooktop Is to be completely enclosed In a cabinet feed the cooktop cable through the opening in the cabinet Make the electrical connection following the appropriate steps for your installation This appliance is manufactured with a green ground wire connected to the cooktop chassis After making sure that the power has been turned off connect the flexible conduit from the cooktop to the junction box using a U L listed conduit connector Figures 14 and 15 and the instructions provided below present the most common way of connecting the cooktops Your local codes and ordinances of course take precedence over these instructions Complete electrical connections according to local codes and ordinances Risk of Electric Shock frame grounded to neutral of appliance through a link Grounding through the neutral conductor is prohibited for new branch circuit installations 1996 NEC mobile homes and recreational vehicles or in an area
22. le four est agr pour cette utilisation et obtenir les dimensions correctes de d coupe 1 1 2 4 cm min INST 022 n Manuel d Installation Qy Mod les ECCB TCCB 30 36 HANNE Dimensions du Produit et D coupe TOUCH CONTROL 30 76 2 cm INST 034 ENERGY REGULATOR 21 36 91 4 cm 21 53 3 cm 30 76 2 cm 53 3 cm ES 21 53 3 cm 21 53 3 cm INST 033 Figure 2 R gulateur d nergie Energy Regulator f Manuel d installation 93 Mod les ECCB TCCB 30 36 BENNE DIMENSIONS DE LA DECOUPE LONGUEUR DE DECOUPE LONGUEUR DE DECOUPE A B VOIR NOTE DU BORD DE LA D COUPE R AU BORD ANT RIEUR DU 1 1 2 3 8 cm PLAN DE TRAVAIL ESPACE MINIMUM 2 1 2 6 35 cm LES REVETEMENTS DES MEUBLES ET LE PLAN DE TRAVAIL DOIVENT RESISTER A UNE CHALEUR DE 93 C 200 F INST 023 3 Figure 3 Dimensions pour la d coupe 18 SLOT POUR CABLES 3 1 2 9 cm 2 1 2 6 5 cm INST 035 3 HOME APPLIANCES Manuel d Installation Mod les ECCB TCCB 30 36 HE D COUPE LARGEUR A B C D E F G 28 1 2 19 1 4 18 45 7 cm 30 76 2 2 5 30 72 4 cm 49 0 cm T min ME cm E a 76 2cm 29 19 5 8 Hauteur min voir note Space min 13 33 cm 76 2 cm min de la d coupe 73 7 cm 49 8 cm du plan de N f Profondeur des
23. lley Rd Cleveland OH 44131 5575 Para prevenir el riesgo de incendios por recalentamiento de superficies es aconsejable evitar la colocaci n de armarios sobre la placa de cocci n Si desea colocar un armario sobre la placa puede reducir el riesgo instalando una campana extractora que se superponga al armario al menos 12 7 cm y lo proteja 28 Instalaci n de la placa sobre un horno Solo algunos modelos de placas de cocci n y hornos est n dise ados para instalaciones combinadas Las placas de cocci n homologadas para este tipo de instalaci n deben tener una etiqueta que lo indique en el exterior de la caja de los quemadores Si no encuentra esa etiqueta p ngase en contacto con el vendedor para confirmar si la placa de cocci n est homologada para ese tipo de instalaci n En la parte inferior de la placa de cocci n hay una etiqueta que recoge las combinaciones aprobadas para este tipo de instalaci n Los hornos homologados para este tipo de instalaci n deben tener la etiqueta de aprobaci n en la parte superior Si no encuentra esa etiqueta p ngase en contacto con el vendedor para confirmar si el horno est homologado para ese tipo de instalaci n Lea las Instrucciones de instalaci n del fabricante del horno para asegurarse de que est homologado para una instalaci n combinada En ellas encontrar tambi n las dimensiones del hueco de encastre 1 1 2 4 cm min INST 022 f Manual de In
24. luminio Scotch 425 o 427 alrededor del hueco de forma que se doble sobre la encimera y los laterales e No pegue la cinta por debajo de la placa de cocci n aseg rese de que la cinta se extiende m s all del borde exterior de la placa de cocci n Todas las esquinas deben estar recubiertas con cinta 35 e HOME APPLIANCES Manual de Instalaci n Modelos ECCB TCCB 30 36 EAN Conexiones El ctricas Pevicro Desconecte la electricidad antes de instalar el producto Si no lo hace podria correr peligro de muerte o de sufrir una descarga el ctrica Informaciones generales Esta placa de coccion no requiere conexion del neu tro Si va a colocar la placa en un armario asegurese de que en l hay una abertura para pasar el cable de alimentaci n Efect e la conexi n el ctrica siguiendo los pasos adecuados para su instalaci n La placa debe estar conectada al voltaje y la frecuen cia adecuados tal y como se indica a la derecha WHEN Figura 13 Locacion numero di serie Utilice nicamente cableado de cobre Si su vivienda tiene cableado de aluminio siga este procedimiento 1 Conecte el cable de aluminio al cable de cobre utilizando los conectores espec ficos dise ados y garantizados por Underwriters Laboratories UL para conectar cobre y aluminio Siga el procedi miento recomendado por el fabricante del conec tor el ctrico 2 La conexi n aluminio cobre debe estar conforme con l
25. n meuble posez le c ble de la table de cuisson travers l ouverture du meuble Faites les branchements lectriques en suivant les ta pes appropri es pour votre installation Cet appareil est fabriqu avec un conducteur de terre vert connect au ch ssis du table de cuisson Apr s vous tre assurer qu il n y a plus de courant branchez le conduit flexible depuis le table de cuisson jusqu au bo tier de raccordement en utilisant un connecteur de conduit U L listed Les figures 14 et 15 et les instruc tions fournies pr sentant la mani re la plus commune de brancher un table de cuisson Vos codes locaux et r glements sont videmment prioritaires sur ces ins tructions Effectuez les connexions lectriques conform ment aux codes locaux et les r glements Dancer Risque d lectrocution cadre la masse une position neutre d un appareil par une liaison Mettre la masse par un conducteur neutre est interdit pour les nouvelles installations de circuit lectrique 1996 NEC les mobile homes et les v hicules de parc ou dans les r gions o les codes locaux interdisent de brancher la masse travers un conducteur neutre Connexion 3 fils O les codes locaux voir figure 14 permettent la connexion du conducteur de terre du four au fil neutre du circuit de branchement fil gris ou color blanc 1 Siles codes locaux le permettent connectez le conducteur de terre vert du table de cuisson e
26. olf for Cooktops Built in Electric HOME APPLIANCES Models ECCB 30 TCCB 30 ECCB 36 TCCB 36 IMPORTANT FOR OWNER Save these instructions for the local electrical inspector use Leave this manual with owner for future reference IMPORTANT POUR LE PROPRIETAIRE Gardez ces instructions pour une utilisation d inspection lectrique locale Le propri taire doit garder ce manuel pour de futures r f rences IMPORTANTE PARA EL PROPIETARIO Guarde estas instrucciones para el uso del inspector el ctrico local Deje este manual al propietario para futuras referencias v The contents are subject to change without notice HOME APPLIANCES Table of Contents Page Special Warnings s ries 4 Product Dimensions and Cutout Requirements 5 Important Preparation Suggestions 7 Cooktop Installation 8 Electrical Connections 12 General information 12 3 Wire branch circuit 13 4 Wire branch circuit 13 Installation Manual Models ECCB TCCB 30 36 Q Pay attention to these symbols present in this di Dancer manual You can be killed or seriously injured if you don t IMMEDIATELY follow instructions WARNING This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others You can be killed or seriously injured if you don t follow these instructions READ AND SAVE THESE I
27. os c digos locales y con las pr cticas indus triales aprobadas El conducto flexible suministrado con el producto de 100 cm de longitud que se encuentra en la parte tras era derecha de la caja de la placa debe conectarse directamente a la caja de empalme No corte el con ducto Debe conectar un conector aprobado por UL o CSA en cada extremo del cable de alimentaci n en la placa y la caja de empalme Es recomendable ins talar tambi n un fusible de acci n retardada o un dife rencial No utilice como toma de tierra una tuber a de gas No conecte la toma de tierra o el circuito neutro 36 cerca de un fusible Instale fusibles en las dos l neas fases de alimentaci n ADVERTENCIA Una conexi n inadecuada del cableado de alumi nio al cableado de cobre puede provocar graves problemas Calibre Modelo Potencia Alimentaci n m n ca bleado TCCB 33052 TCCB 33053 TCCB 33066 TCCB 33067 67kW 240 V 28A No ECCB 33050 60 Hz 10AWG ECCB 33051 ECCB 33070 ECCB 33071 TCCB 33656 TCCB 33657 76kW 240V 32A No TCCB 33668 60 Hz 10AWG TCCB 33669 ECCB 33654 ECCB 33655 94kW 240 V 39A No ECCB 33674 60 Hz 10AWG ECCB 33675 N meros de referencia del color National Fire Protection Association Batter march Park Quincy Massachusetts 02269 Debe instalarse un sistema el ctrico de tres cables una fase 240 voltios y 60 ciclos
28. ravail et les meubles autour de la table de cuisson r sistent la chaleur jusqu 200 F 93 C 20 HOME APPLIANCES Etape 1 Enlevez les materiaux demballage et les manuels d explication de la table de cuisson avant de commencer l installation Retirez les Instructions d installation du manuel et lisez les soigneusement avant de commencer PANNEAU CARTON SUP RIEUR gt MANUEL lt gt JOINT RACLOIR LAME lt DE RASOIR EMBALLAGE DU HAUT CARTON INST 024 3 Figure 5 Pi ces Manuel d Installation Mod les ECCB TCCB 30 36 de E tape 2 Placez un torchon ou une serviette sur le plan de travail Posez la table de cuisson du haut vers le bas dans la surface prot g e CAISSON DES FOYERS SERVIETTE abria Figure 6 tape 3 Un ruban adh sif est fourni pour assurer l tanch it entre les bords de la table de cuisson et les angles du plan de travail Appliquez le ruban environ 1 16 1 5 mm des angles en verre au dos du verre de la table de cuisson Utilisez un ruban tout autour du p rim tre du verre Coupez le ruban en trop CAISSON DES FOYERS RUBAN ADH SIF TANCHE VERRE DE LA TABLE DE CUISSON RSS Figure 7 21 HOME APPLIANCES tape 4 Quatre supports de fixation sont fournis pour accrocher la table de cuisson au plan de travail Le support peut tre install avant de placer la table de cuisson dans la d coupe Installez les supports
29. rique de 240 volt 60 cycles circuit pro t g correctement pour tre conforme aux codes lo caux de NFPA No 70 L appareil doit tre correcte ment branch selon le code de c blage local Le ta bleau ci dessous recommande le protecteur de cir cuit minimum et la taille de c ble minimum si l appareil situ l arri re droite sous le caisson de la table de cuisson doit tre connect directement la bo te de jonction Ne coupez pas le conduit Un raccord de conduit U L ou CSA listed doit tre pos chaque extr mit du c ble d alimentation lectrique la table de cuisson et la bo te de jonction Un dispositif de surcharge ou un disjoncteur est recommand 24 est le seul sur le circuit Si des tailles de c ble plus petites sont utilis es l efficacit de l appareil sera r duite et un risque d incendie est possible II est conseill que le c blage lectrique et le branchement soit mis en place par un lectricien comp tent HOME APPLIANCES Minimum recommand Caract ristiques des Protection de Taille de kW sur plaques de circuit en am c ble s rie p res AWG Assurez vous que votre installation est correcte ment install e et branch e par un technicien quali fi Demandez votre revendeur un technicien qualifi ou un service de r paration agr Cette table de cuisson n exige pas de connexion neutre Si la table de cuisson doit tre compl tement en ferm e dans u
30. rotate the brackets so that they cooktop to the countertop The bracket may be extend beyond edge of the burner box Tighten installed before the cooktop is placed into the cutout Screws securely Install the clamp brackets as shown on the front and back of the box then rotate brackets so that they do not extend beyond edge of burner box bottom Tighten screws just enough to hold brackets in place when cooktop is put into cutout CLAMP BRACKETS Figure 10 INST 027 2 Figure 8 Step 5 Insert the cooktop centered into the cutout opening Make sure the front edge of the counter top is parallel to the cooktop Make final check that all required clearances are met INST 028 Figure 9 10 Installation Manual Models ECCB TCCB 30 36 JNB E z HOME APPLIANCES ELECTRIC LINE OPENING A 12 30 5 cm MIN FROM BOTTOM OF COUNTERTOP AND ADJACENT CABINET RIGHT SIDE SHOWS LOCATIONS OF ALUMINUM REFLECTIVE TAPE TAPE TOP AND VERTICAL SIDES OF CUTOUT INSTALL JUNCTION BOX t SO THAT IT CAN BE REACHED TROUGH THE FRONT OF THE CABINET MAA AA AAA AAA SOLID SURFACE COUNTERTOP INSTALLATION INST 0052 Figure 12 INST 030 2 WARNING Figure 11 THE CONDUIT IS 3 FEET LONG The junction box must be located where it will allow considerable slack in the conduit for serviceability Important e For solid surface material installations such as Surel and Corian consult wi
31. s mentionn es ci dessus peuvent tre obtenues National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Rd Cleveland OH 44131 5575 Pour viter le risque de br lures en touchant les surfaces chauff es l espace de stockage du meuble au dessus des unit s de surface doit tre vit Si le meuble de stockage est fourni le risque peut tre r duit en installant une hotte qui proj te horizontalement un minimum de 5 12 7 cm sous le dessous du meuble 16 Table de cuisson installe au dessus d un four Uniquement certains fours et tables de cuisson sont agr s pour tre install l un au dessus de l autre Les tables de cuissons agr s pour ce type d installation ont une tiquette d homologation situ sur l ext rieur de la caisse du br leur Si vous ne trouvez pas cette tiquette contactez votre distributeur afin qu il vous confirme que votre table est agr e L tiquette en dessous de votre table de cuisson mentionne les combinaisons possibles de table de cuisson et four qui sont agr s pour ce type d installation Les fours agr s pour ce type d installation auront une tiquette d homologation situ e au dessus du four Si vous ne trouvez pas cette tiquette contactez le distributeur pour vous confirmer le four est agr pour cette installation Se reporter aux instructions d installation du fabricant du four pour savoir si
32. sheet steel 0 015 0 04 cm stainless steel or 0 024 0 06 cm aluminum or 0 020 0 05cm copper 30 76 2 cm min clearance between top of cooking platform and bottom of unprotected wood or metal cabinet Important Preparation Suggestions Chamfer all exposed edges of decorative laminate to prevent damage from chipping Radius corners of cutout and file to Insure smooth edges and prevent corner cracking Recommend 1 4 or 3 8 diameter drill In each corner Rough edges inside corners which have not been rounded and forced fits can contribute to cracking of the countertop laminate This cooktop has been designed with wide tolerances of cut out to cover possible replacement with other brands We recommend to that you consider the minimum dimension of cut out size In the case of new Installation Some cut out sizes for possible replacements Dim Inches cm e 30 29 x 19 5 8 73 7 x 49 8 e 36 34 9 16 x 19 5 8 87 8 x 49 8 n Installation Manual 93 Models ECCB TCCB 30 36 NME Cooktop Installation A WARNING e Excessive Weight Hazard Use two or more people to move and install cooktop Failure to do so can result in back or other injury e Cut Hazard Beware of sharp edges Use the polystyrene ends when carrying the product Failure to use caution could result in minor injury or cuts e Always consult the countertop manufacturer for sp
33. stalaci n Qy Modelos ECCB TCCB 30 36 ZM Dimensiones del Producto y de Encastre TOUCH CONTROL 30 76 2 cm 36 91 4 cm INST 034 ENERGY REGULATOR 21 30 76 2 cm 53 3 cm INST 033 Figura 2 Regulador de energ a Energy Regulator 29 Manual de Instalacion Modelos ECCB TCCB 30 36 FS HOME APPLIANCES DIMENSIONES DEL HUECO DE ENCASTRE LONGITUD DEL CORTE ANCHURA DEL CORTE A B VER NOTA DESDE EL BORDE DEL SLOT POUR R CORTE AL BORDE FRONTAL CABLES 1 1 2 8 8 cm DE LA ENCIMERA 3 1 2 9 cm ESPACIO MINIMO 2 1 2 6 35 cm 2 1 2 6 5 cm INST 035 3 LOS ARMARIOS DE LA PARED Y LA ENCIMERA DEBEN PODER SOPORTAR TEMPERATURAS DE HASTA 93 C 200 F INST 023 4 Figura 3 Dimensiones de encastre 30 HOME APPLIANCES Manual de Instalacion Modelos ECCB TCCB 30 36 BSZA ANCHO DEL A B C D E F G CORTE 28 1 2 19 1 4 18 45 7 cm 30 76 2 cm 30 72 4 cm 49 0 cm 30 min min ver nota de m 13 33 cm 76 2cm 29 19 5 8 76 2 cm min Distancia m nima Espacio e a NS Fondo de los 73 7 cm _ 49 8 cm desde la encimera m nimo desde corte en los armarios 33 7 8 19 1 4 hasta la base del la encimera fados izquierdo superiores no 38 86 cm 49 0 cm no armaria mas nasta una dae de la Do idos 91 4 cm 34 9 16 19 5 8 91
34. t le fil neutre du circuit de branchement fil gris ou co lor blanc 2 Connectez les broches de raccordement du table de cuisson aux broches de raccordement corres pondantes dans le bo tier de jonction Manuel d Installation Mod les ECCB TCCB 30 36 ds XIIe AES CABLE 3 FILS DE LA TABLE DE CUISSON CABLES ROUGES BOITE DE JONCTION CONNECTEUR VERROUILLE PAR ROTATION LA TABLE DE CUISSON CONNECTEUR DE CONDUIT UL OU CSA LISTED Si les r glements locaux ne permettent pas de branchement de conducteur la masse de ch ssis au c ble neutre blanc de la boite de jonction non utilis pour les installations canadiennes INST 031 3 Figure 14 Connexion 4 fils 1 Connectez voir figure 15 le conducteur de terre vert du table de cuisson au conducteur de terre dans le bo tier de jonction c ble nu ou color vert 2 Connectez les broches de raccordement rouge et noir du table de cuisson aux broches de raccor dement correspondantes dans le boitier de raccor dement 3 Connectez le c ble vert du table de cuisson du c ble neutre gris ou blanc dans le boitier de raccor dement 4 Raccordez et isolez le c ble neutre gris ou blanc la boite de jonction CABLE 3 FILS DE LA TABLE DE CUISSON CABLES ROUGES BOITE DE JONCTION CONNECTEUR VERROUILLE LA TABLE DE CUISSON PAR ROTATION CABLES NOIRS INST 0329 CONNECTEUR DE CONDUIT UL OU CSA LISTED Figure 15 25 o HOME w APPLIANCES
35. th solid surface manufacturer Apply heat reflective tape such as Scotch Aluminum Foil Tape 425 or 427 around the cutout so that it folds over on the top and sides e Do not wrap the tape underneath the cooktop Be sure the tape extends beyond the outermost flange of the cooktop All corners should be covered with tape e HOME APPLIANCES Installation Manual Models ECCB TCCB 30 36 ANR Electrical Connections pancen Disconnect power before servicing the product Failure to do so could result in death or electrical shock General information This cooktop does not require a neutral connection If the cooktop is to be completely enclosed in a cabinet feed the cooktop cable through the opening in the cabinet Make the electrical connection following the appropriate steps for your installation Your cooktop must be connected to the proper electrical voltage and frequency as specified in the table on the right NA Figure 13 Location of serial tag Connect with copper wire only Ifthe house has aluminum wiring follow the procedure below 1 Connect the aluminum wiring to the copper wire by using special connectors designed and Underwriters Laboratories listed for joining copper to aluminum Follow the electrical connector manufacturer s recommended procedure 2 Aluminum copper connection must conform with local codes and industry accepted wiring practices The flexible conduit Supplied 3
36. ual de Instalaci n Modelos ECCB TCCB 30 36 ESO HOME APPLIANCES Paso 1 Paso 2 Retire el embalaje y separe los manuales de Coloque una toalla o un mantel sobre la encimera instrucciones antes de comenzar la instalaci n Apoye la placa de cocci n boca abajo sobre la Lea atentamente el manual de instalaci n antes de superficie protegida comenzar CAJA DE LA PLACA CART N SUPERIOR MANUAL gt JUNTA RASCADOR er EMBALAJE SUPERIOR MANTEL INST 025 4 Figura 6 Paso 3 En el embalaje encontrara una cinta de espuma que CARTON sirve para sellar el per metro de la placa de cocci n Aplique la cinta en la parte trasera de la placa de NS cocci n en todo el per metro aproximadamente a 1 5 mm del borde de cristal Recorte los extremos sobrantes INST 024 4 CAJA DE LA PLACA l Figura 5 Piezas CINTA SELLADORA CRISTAL DE LA PLACA INST 026 4 Figura 7 33 HOME APPLIANCES Paso 4 En el embalaje encontrar tambi n cuatro grapas de fijaci n Puede acoplarlas antes de instalar la placa en el hueco de encastre Acople las grapas de fijaci n como indica la imagen en la parte delantera y trasera de la caja de la placa y g relas para que no sobresalgan del borde de la base de la caja Apriete los tornillos solo lo necesario para mantenerlos en su posici n mientras coloca la placa en el hueco GRAPAS DE FIJACI N INST 027 4 Figura 8 34 Manual de
37. where local codes prohibit grounding through the neutral conductor 3 Wire branch circuit Where local codes allow the connection of ground wire from the cooktop to the branch circuit neutral wire gray or white colored wire proceed as follows see figure 14 1 If local codes permit connect the green GROUND wire from the cooktop to the branch circuit neutral wire gray or white colored wire 2 Connect the red and black leads from the cooktop to the corresponding leads in the junction box Installation Manual Models ECCB TCCB 30 36 AcMs 3 WIRE CABLE FROM POWER SUPPLY RED WIRES JUNCTION BOX TWIST ON CONNECTOR BARE OR GREEN WIRES 3 WIRE CABLE FROM COOKTOP U L OR CSA LISTED CONDUIT CONNECTOR Where local codes permit connecting the frame ground conductor to the neutral white junction box wire Not used for Canadian installations INST 031 2 Figure 14 4 Wire branch circuit Refer to figure 15 1 Connect the green ground wire from the cooktop to the ground wire in the junction box bare or green colored wire 2 Connect the red and black leads from the cooktop to the corresponding leads in the junction box 3 Connect the white wire from the cooktop to the neutral gray or white wire in the junction box 4 Terminate and insulate the neutral gray or white colored wire in the junction box RED WIRES JUNCTION BOX WHITE WIRE BARE OR GREEN WIRES 3 WIRE CABLE FROM COOKT