Home

Euro-Pro EP603H User's Manual

image

Contents

1. The non woven pre filter pre motor and post motor filters are washable They should however be replaced every three 3 months to ensure peak performance of your vacuum Important Make sure that ALL filters have completely air dried before re installing back in the vacuum Changing amp Cleaning the Pre Motor Filter The pre motor filter is a washable filter but should be replaced every three 3 months e Remove the dust cup container the Non Woven Pre Filter and the HEPA filter to remove the pre motor filter Fig 13 Rinse the pre motor filter in lukewarm water and air dry the filter completely for 24 hours Do not use a washing machine to rinse the filter Do not use a hair dryer to dry it Air dry only Never operate the vacuum without the pre motor filter in place When the filter is dry replace into the unit and replace the HEPA filter and dust cup container A severely soiled or clogged filter should be thoroughly washed with fresh tepid water A mild detergent can be used if required Fig 13 Ghanaing amp Cleaning the Post Motor Filter The post motor filter is a washable filter but should be replaced every three 3 months Remove the filter cover from the front of the unit and remove the filter Fig 14 Rinse the post motor filter in lukewarm water and air dry the filter completely for 24 hours Do not use a washing machine to rinse the filter Do not use a hair dryer to dry it Air d
2. a power cord which is automatically retractable To extend your power cord pull from side and extend to desired length up to the yellow mark on the power cord Fig 5 USING THE UNIT AS A HAND VACUUM Press the telescopic tube release button to remove the telescopic tube See Fig 2 page 4 Press the floor brush release button to oo remove the floor brush See Fig 3 E ie page 4 CR Attach the shoulder strap to the ni shoulder strap attachment point Do not pull the power li rN Big 6 j P cord beyond the red y HE Red e Attach the crevice tool or the dusting mark When vacuuming brush to the end of the hose is finished first switch Fig 5 off power and disconnect plug from electrical outlet Then press on cord rewind button If the cord does not fully retract pull it out again and then press on cord rewind button Warning Hold the plug when rewinding the cord Do not allow the cord to whip when rewinding Warning After extended use the body of the vacuum cleaner may become hot When using the unit with the shoulder ON OFF SWITCH VM SS strap the unit will touch the body of the E Off switch has two different user Therefore make sure that the unit EE body is cool before you use with the Push on the l side to turn the shoulder strap If during use the vacuum vacuum ON gets too warm allow it to cool before continuing to use Crevice Tool For radiators crevices corners base
3. LLC liable for incidental or consequential damages of any nature whatsoever Some states do not permit the exclusion or limitation of incidental or consequential damages so the above may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state or province to province Important Carefully pack item to avoid damage in shipping Be sure to include proof of purchase date and to attach tag to item before packing with your name complete address and phone number with a note giving purchase information model number and what you believe is the problem with item We recommend you insure the package as damage in shipping is not covered by your warranty Mark the outside of your package ATTENTION CUSTOMER SERVICE We are constantly striving to improve our products therefore the specifications contained herein are subject to change without notice OWNERSHIP REGISTRATION CARD Please fill out and mail the product registration card within ten 10 days of purchase The registration will enable us to contact you in the unlikely event of a product safety notification By returning this card you acknowledge to have read and understood the instructions for use and warnings set forth in the accompanying instructions RETURN TO EURO PRO Operating LLC 94 Main Mill Street Door 16 Plattsburgh N Y 12901 Model EP603H Appliance model Date purchased Name of store Owner s name
4. PRO Operating LLC 4400 Bois Franc St Laurent QC H4S 1A7 If the appliance is found by EURO PRO Operating LLC to be defective in material or workmanship EURO PRO Operating LLC will repair or replace it free of charge Proof of purchase date and 16 95 to cover the cost of return shipping and handling must be included Non durable parts including without limitation filters brushes and electrical parts which normally require replacement are specifically excluded from warranty The liability of EURO PRO Operating LLC is limited solely to the cost of the repair or replacement of the unit at our option This warranty does not cover normal wear of parts and does not apply to any unit that has been tampered with or used for commercial purposes This limited warranty does not cover damage caused by misuse abuse negligent handling or damage due to faulty packaging or mishandling in transit This warranty does not cover damage or defects caused by or resulting from damages from shipping or repairs service or alterations to the product or any of its parts which have been performed by a repair person not authorized by EURO PRO Operating LLC This warranty is extended to the original purchaser of the unit and excludes all other legal and or conventional warranties The responsibility of EURO PRO Operating LLC if any is limited to the specific obligations expressly assumed by it under the terms of the limited warranty In no event is EURO PRO Operating
5. opening and moving parts Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes Use extra care when cleaning on stairs Do not use the vacuum without ALL the filters in place This appliance is intended only for household use Follow all user instructions in this manual To reduce the risk of fire electric shock or injury Do not leave the Retractable Stick plugged in when unattended Unplug the electrical cord when not in use and before servicing Do not allow to be used as a toy Close attention is necessary when used by or near children pets or plants Use only as described in this manual Use only manufacturer s recommended accessories Do not pull cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Keep cord away from heated surfaces Use only extension cords UL rated or cUL at 15 amperes Extension cords rated for less amperage may overheat Care should be taken to arrange the cord so that the cord cannot be pulled or tripped over Turn off all controls as applicable before unplugging from electrical outlet Do not handle plug or vacuum with wet hands or operate without shoes Do not put any objects into openings Do not use with any opening blocked Keep free of dust lint hair and anything else that may reduce a
6. A Filter and clean Debris Screen and Non Woven Pre Filter until no more dust can be removed IMPORTANT Please Note The TapClean HEPA Filter will stop most of the tiniest dust particles from re entering the air you breathe In fact it stops 99 97 of all particles as small as 0 3 microns many times smaller than a human hair Because of this incredible filtration performance the HEPA Filter will quickly accumulate inside the white filter folds many fine dust particles that are difficult to see but which will eventually block or reduce your suction power if not cleaned properly 1 To remove the dust cup container first press on the dust cup release button 1 that is located on the dust cup handle and at the same time press on the dust cup release button 2 that is on the side of the upper housing Fig 7 Then pull the dust cup container out Dust Cup Release Button 1 Dust Cup Release Button 2 2 To empty the dust cup container press on the trap door release button that is on the back side of the dust cup container Fig 8 3 The HEPA filter is located underneath the dust cup container Fig 9 Remove the Non Woven Pre Filter Fig 10 Remove the HEPA filter hold the edges and pull it out slowly Fiker aim Non Woven Hu A e Filter li ni u i nz f l HEPA MTT Fig 10 Filter HEPA iy J 4 Hold the HEPA filter by the edges and vigorously TapClean the HEPA F
7. Address City State Zip code Printed in China 10 ORDERING REPLACEMENT DUST CUP FILTERS GETTING TO KNOW YOUR RETRACTABLE STICK VAC TO ORDER REPLACEMENT HEPA FILTERS for Model EP603H Call 1 800 798 7398 Monday to Friday 8 30 A M 5 00 P M Eastern Standard Time FOR TECHNICAL SUPPORT for Model EP603H Call 1 800 798 7398 Af Monday to Friday 8 30 A M 5 00 P M Eastern Standard Time 20 3 SS NP d Sij z C im rs i Please Note The HEPA Filter is washable It should however be replaced every three 3 to six 6 months depending on usage to ensure peak performance of your vacuum The Pre Motor the Non Woven Pre Filter and Post Motor Filters are 13 12 washable They should however be replaced every three 3 months 1 depending on usage to ensure peak performance of your vacuum Important Make sure that ALL filters have been completely air dried for 24 hours before 10 re installing back in the vacuum 1 Hand Grip 11 Cord Retractor 2 Locking Button 12 Cord Retractor Button 3 Dust Cup Release Button 1 13 On Off Switch 4 Dust Cup Handle 14 Flexible Hose 5 Dust Cup Container 15 Telescopic Tube 6 Intelli Sense Filter 16 Dusting Brush Monitor 17 Telescopic Tube Release 7 Exhaust Filter Cover Button 8 Floor Brush 18 Crevice Tool 9 Floor Brush Release Button 19 Dust Cup Release Button 2 10 Main Unit 20 Flexible Hose Clip 21 Shoulder Strap not shown Technical Specif
8. EURO PRO X Retractable Stick Vac OWNER S MANUAL Model EP603H 120V 60Hz 10 Amps EURO PRO Operating LLC U S 94 Main Mill Street Door 16 Canada 4400 Bois Franc Plattsburgh NY 12901 St Laurent QC H4S 1A7 Tel 1 800 798 7398 IMPORTANT SAFETY INSTRUCTIONS When using your Retractable Stick Vac basic safety precautions should always be observed including the following 1 2 3 eo 10 11 12 13 14 Read all instructions before using your Retractable Stick Vac Use the system only for its intended use To protect against a risk of electric shock do not immerse any part of the system in water or other liquids Never yank cord to disconnect from outlet instead grasp plug and pull to disconnect Do not allow cord to touch hot surfaces Do not run appliance over cord Do not operate the system with a damaged cord or plug or if the appliance or any other part of the system has been dropped or damaged To avoid the risk of electric shock do not disassemble or attempt to repair the unit Return the system to EURO PRO Operating LLC see warranty for examination and repair Incorrect re assembly or repair can cause a risk of electrical shock or injury to persons when the vacuum is used Close supervision is necessary for any appliance being used by or near children Do not leave the system unattended while connected Keep hair loose clothing fingers and all parts of body away from
9. boards and ms between cushions Dusting Brush The dusting brush is used for the furniture He venetian blinds S CN books lamp shades ST and shelves Intelli Sense Filter Monitor When the Intelli Sense Filter Monitor lights up it means that the dust cup is full the HEPA filter non woven pre filter or debris screen need cleaning You must empty the dust from the dust cup and clean the HEPA filter non woven pre filter or debris screen Also check the hose and attachments to see if they are blocked with any debris If they are unblock them e Push on the O side to turn the vacuum OFF e a USING THE UNIT AS AN UPRIGHT Unwind the power cord and plug into the 120V outlet e Push down on the locking button to adjust the height of the telescopic handle NOTE When vacuuming deep pile carpets or hard to vacuum carpets jd pe Jh lower the angle of j Les the telescopic handle see illustration at right for easier maneuverability OPERATING INSTRUCTIONS Emptying the Dust Cup Container and Cleaning Changing the Non Woven Pre Filter HEPA Filter amp Debris Screen Warning Always unplug the unit from electrical outlet before opening the Dust Cup container Important Do NOT use the vacuum without the HEPA filter in place Warning After each Use Always remove Filter Assembly and the Dust Cup Cover with the Debris Screen then vigorously TapClean HEP
10. ications Voltage 120V 60HZz Power 10 Amps Illustrations may differ from actual product PRECAUTIONARY MEASURES IMPORTANT If the suction opening in the unit or the hose is BLOCKED switch off the vacuum cleaner and remove the blocking substance before you start the unit again Do not operate the vacuum cleaner too close to heaters radiators or cigarette butts Before inserting the power plug into the wall outlet make sure that your hands are dry Before you start vacuuming make sure to remove large or sharp objects that might damage the dust cup debris screen 4 When pulling out the power plug from the wall outlet pull the plug not the power cord 5 Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes 6 Do not use without ALL filters in place Warning Hold the plug when rewinding the cord Do not allow the cord to whip when rewinding Motor Thermostat IMPORTANT This unit is equipped with a motor protective thermostat If for some reason the vacuum cleaner should overheat the thermostat will automatically turn the unit off Should this occur Push the On Off button once e Disconnect the plug from the power source e Check the source of overheating problem i e clogged hose or filter OPERATING INSTRUCTIONS If clogged hose or filter is found unclog the hose and replace the filters Wait at least 45 minute
11. ilter dirty side down on a hard flat surface until no more dust is observed falling out from between the pleats of the filter Fig 11 We Ign recommend washing the HEPA filter once a month or when suction appears to be reduced Let the HEPA filter air dry completely for 24 hours 5 Rinse the non woven pre filter and let air dry completely for 24 hours 6 Insert the non woven pre filter 7 Reinstall the HEPA filter in the vacuum 8 To separate the debris screen from the dust cup hold the dust cup in one hand and turn the dust cup cover counte clockwise and pull api To clean the debris gt Screen we recommer that you rinse it under 5 ae lukewarm running wa PAR m to remove the dirt thai Fig 12 accumulates on it but always allow it to completely air dry before inserting back into the vacuum Fig 12
12. ir flow Store your appliance indoors in a cool dry area Keep your work area well lit Keep end of hose wands and other openings away from your face and body Warning Hold the plug when rewinding the cord Do not allow the cord to whip when rewinding Use only on dry surfaces Using improper voltage may result in damage to the motor and possible injury to the user Correct voltage is listed on rating label SAVE THESE INSTRUCTIONS For Household Use Only WARNING To reduce the risk of electric shock this appliance has a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not modify the plug in any way Rev 06 05 Model EP603H EURO PRO X ONE 1 YEAR LIMITED WARRANTY EURO PRO Operating LLC warrants this product to be free from defects in material and workmanship for a period of one 1 year from the date of the original purchase when utilized for normal household use subject to the following conditions exclusions and exceptions If your appliance fails to operate properly while in use under normal household conditions within the warranty period return the complete appliance and accessories freight prepaid to US EURO PRO Operating LLC 94 Main Mill Street Door 16 Plattsburgh NY 12901 CANADA EURO
13. r material in the HEPA Filter will discolor over time This is NORMAL and will NOT affect the performance of the filter If the HEPA Filter is properly Fig A TapCleaned after each use Wash and suction once a does not return i month or when to 100 then suction we suggest that appears reduced the HEPA filter be TapCleaned vigorously until no more dust can be removed then rinsed under the faucet and allowed to dry for 24 hours before refitting into the vacuum Fig A This should be done once a month or when suction appears to be reduced Warning Allow 24 hours for drying before replacing in unit CAUTION The suction hole must be open free of any obstructions at all times Otherwise the motor will overheat and could become damaged Warning Always empty the dust cup container and clean the HEPA filter Non Woven Pre Filter and Debris Screen before each use and during prolonged usage Never over fill the dust cup container remove dirt and clean the HEPA filter non woven pre filter and debris screen when dirt in dust cup is at or below the MAX level during prolonged usage or risk motor damage If you wash the Hepa filter or the non woven pre filter make sure that they have completely air dried before inserting back in the vacuum Please Note The HEPA Filter is washable It should however be replaced every three 3 to six 6 months to ensure peak performance of your vacuum
14. ry only Never operate the vacuum without the post motor filter in place When the filter is dry replace into the Fiter filter cover and replace the filter cover to the unit e A severely soiled or clogged filter should be thoroughly washed with fresh tepid water A mild detergent can be used if required WARNING Always remove the power plug from the wall outlet before assembling or removing accessories EXTENDING THE TELESCOPIC IUBE Push the locking button and pull the larger tube up Fig 1 477 Locking Button Fig 1 INSERTING THE TELESCOPIC TUBE INTO THE MAIN UNIT Insert the telescopic tube into the hole next to the dust cup handle Make sure that the slot in the handle fits correctly into the opening Fig 2 To remove the telescopic tube press the telescopic tube release button and pull the tube up Telescopic Tube Release Button ATTACHING THE FLOOR BRUSH TO THE MAIN UNIT e Insert the floor brush into its location in the direction of the arrow Fig 3 e To remove the floor brush from the main unit press on the floor brush release button and pull the floor brush out J hy LS Floor Brush L T Release AL Button eo Fig 3 ATTACHING THE HOSE TO THE MAIN UNIT Hold the end of the hose Insert the hose into the hose connector Fig 4 OPERATING INSTRUCTIONS WINDING amp UNWINDING THE POWER CORD Your vacuum cleaner includes
15. s before attempting to reuse the vacuum After unit has cooled down for 45 minutes plug in the cleaner and push the On Off button The vacuum should start again If the vacuum still does not start contact customer service at 1 800 798 7398 TROUBLE SHOOTING GUIDE PROBLEM POSSIBLE REASON POSSIBLE SOLUTION Power cord not firmly plugged into VACUUM WILL outlet NOT OPERATE Dust cup is full VACUUM WILL NOT PICK UP OR SUCTION POWER replacing IS WEAK Unit clogged DUST ESCAPING FROM VACUUM VACUUM HOSE OR BRUSHES WILL NOT PICK UP No power in wall outlet Needs servicing Thermostat has tripped Dust cup is full Dust Cup is not installed correctly Hose clogged Dust cup is full HEPA Filter needs cleaning or Debris screen needs cleaning Filters need cleaning Plug unit in firmly Check fuse or breaker Replace fuse reset breaker Call 1 800 798 7398 Turn the unit off and unplug from outlet Allow unit to cool down then restart Empty and clean dust cup Turn unit off and unplug from wall outlet Remove Dust Cup Filter and check for object s in air duct and remove Clean or replace HEPA Filter Clean debris screen Clean Filters Empty and clean dust cup Review Dust Cup instructions Remove hose and or brushes Remove obstruction from hose and or brush Empty and clean dust cup OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS PLEASE NOTE The white pleated filte

Download Pdf Manuals

image

Related Search

Related Contents

Wireless HD AV Sender & Empfänger Kit für HDMI  la fiche récapitulative hors classe - Sgen-CFDT  viavac – un expert en vaccinations dans votre ordinateur  Guide de l`administrateur Trend Micro™ Hosted Email Security  Samsung SPF-83M User Manual  資料/スチームトラップ  Aerocool Telum  LG-A447 Guide de l`utilisateur  