Home

ESPRIT 616 User's Manual

image

Contents

1. 616 626 KEYPADS Model 676 Model 626 gt PE P R X SYSTEMS P A R D X SECURITY SYSTEMS UM616 626 980130 0006 UM616 626 zr USER FRIENDLY ESPRIT BURGLAR ALARM CONTROL PANEL Welcome to the world of ESPRIT technology Your Esprit control panel has been designed with ease of use and simplicity mind We ve developed a high ly advanced technology control panel with powerful features that ANYONE can use without memorizing complex confusing codes or taking a course in com puter programming Not only is ESPRIT easy to operate with many func tions accessible by one touch of the keypad but it s also functional and stylish We hope that you ve already been impressed by its compact design and attractively styled keypads with their adjustable illu mination levels The dwelling or building that you want to secure can be divided into as many as 24 zones depending upon which model of the ESPRIT panel you require and controlled by up to 5 keypads or PS1 bedside remote arming modules Thanks to the ESPRIT s partitioning feature two distinct systems A and B a dual area assigned to both systems and a common area no system assignment can be created and controlled by the panel Partitioning can be used in installations where shared security systems are more practical such as Control panel software versions 2
2. Zone 19 Zone 20 0 O Zone 21 80 2 22 U Zone 23 O Zone 24 El 29 4 digit ACCESS CODES Code Arming Priority UM616 626 6 digit Reg Stay Away Byp A B Master 00 User 01 LJ 02 O 0 User 04 05 OO User 06 User 07 User 08 User 09 User 10 User 11 OO User 12 User 13 User 14 User 15 User 16 User 17 OO User 18 User 19 User 20 User 21 User 22 User 23 pS a go a a 50 pO a ay a 9 OO 30 Name Code Arming Priority UM616 626 Reg Stay Away Byp A B User 24 User 25 User 26 User 27 User 28 User 29 User 30 User 31 User 32 User 33 User 34 User 35 User 36 User 37 User 38 User 39 User 40 User 41 User 42 User 42 User 43 User 44 User 45 User 46 User 47 User 48 AND NOT ACTUAL ACCESS CODES 31 NOTE FOR SECURITY REASONS WRITE ONLY USER NAMES UM616 626 SPECIAL KEYS AND FUNCTIONS Key 10 Regular arming is activated O Key stay 11 Stay armin
3. force arming See page 13 LIZ CODE WITH PARTITION System B arm disarm key Display When ON this indicates existence of trouble conditions Press to view the trouble codes table Software versions 1 4 and beyond When flashing rapidly indicates power failure indicates alarms were generated while system was armed Press to bring up alarm zones stored in memory CODE Activates manual zone bypassing Select zones to leave open when arming system CLEAR Made a mistake entering info Just press CLEAR to erase any keypad entries and return control panel to previous status Press to store keypad entries in memory 35 UM616 626 IMPORTANT This security system should undergo frequent testing However despite regular testing and due to but not limited to criminal tampering or electrical disruption it is possible for this product to fail to perform as expected WARRANTY Warranty conditions for the Esprit may vary from country to country Please consult your local dealer for complete warranty information In all cases the warranty does not cover malfunctions arising from installer error or failure to follow installation operation instructions nor does it apply to damages due to causes beyond the control of Paradox Security Systems such as lightning excessive voltage mechanical shock or water damage LIABILITY Under no circumstances shall Paradox Security Systems be held liab
4. 00 and beyond 1 UM616 626 office warehouse buildings or apartment condomini um complexes The ESPRIT keypad s comprehensive 12 zone keys 8 function keys and keypad sounder serve to keep you instantly aware of alarm system and operational status Motion detectors smoke and glass break detectors as well as vibration shock and door window contact sensors will all report to ESPRIT s RISC microprocessor brain and vital security information will be communicated to you by the keypad display The ESPRIT can report a wide range of status condi tions to the security central monitoring station Automatic test reports can also be sent to the central station to ensure that your system is functioning prop erly We recommend that such tests be conducted regularly Please consult your installer for instructions Using telephone lines a computer modem amp high security software your security company can perform remote diagnostics and modifications to your ESPRIT panel at your request Your control panel can also be armed remotely should you forget to do so Depending on the panel you may even obtain an activity printout of the last 120 events that occurred in your system All control panels software version 3 00 and beyond will provide a report of the last 256 events This reduces time and expense devoted to security supervision and can be performed in minutes 2 UM616 626 Look Everything you need to know about your secur
5. as they are closed Armed status is indicated by the away key flashing The fire zone cannot be force armed On control panel models 728 728 EXPRESS and 738 EXPRESS using software version 2 1X key indicated will not flash but will be constantly illuminated Software versions 2 2X onward key indicated does not illuminate 13 UM616 626 Note These features are not recommended for regu lar use because leaving zones open can reduce the efficiency of system protection Force arming and auto bypass away arming are ideal for use with over head garage doors movement supervision feature Your panel can be programmed to send a report and or arm the system if it is not armed full or Stay arming and there is no zone activity for a preprogrammed amount of time This is a particularly useful feature when supervising the elderly individuals with chronic health problems or an individual that lives alone Automatically Arm on Time Your installer can program your system to arm at specific time each day In this mode all protected zones and detection devices must be in the normal state before arming can occur Panic zones If you need to signal a panic situation the Esprit provides three panic zones on your keypad These panic zones must be programmed by your installer Pressing keys 1 and 8 simultaneously for 2 sec will generate a panic 1 or if programmed a panic alarm Pressing k
6. can program the panel to reset smoke detectors amp Glasstreks to activate strobe lights to activate light switches in your home or office to reduce or increase building temperature turn on off air conditioning open close automatic garage doors and more Talk to your installer about this helpful feature Keypad night illumination Pressing on the key for 2 seconds changes it to the keypad illumination key Pressing this key will then alter the illumination level from low medium to high and then off Keep pressing the key until you reach the level you require then press ENTER or CLEAR to save the setting in system memory Chime zones Zones 1 to 6 as well as the local keypad zones can be programmed as chime zones A chime zone advises you when it is opened by creating a rapid intermittent beep tone To turn on the chime zone feature press on the selected zone key for three sec onds until the intermittent chime beep is heard This means that the chime feature has been activated If a continuous beep is heard this means that the chime is off The keypad zone chime is enabled by pressing key 8 18 UM616 626 If you have more than one keypad in your system please chime program each keypad separately Keypad chimes must be reprogrammed if the panel suffers total power loss CHIME KEYS Key 1 6 Turns chime on or OFF in zones num bered 1 6 Key 8 Turns the chime
7. each activation If keypad panic keys are enabled check with your installer pushing one of these keys will initiate a local alarm if programmed and a signal to be trans mitted to the monitoring station if programmed Your installer can advise you of the best way to test your particular system Fire Alarm Testing CAUTION Do not use open flame or burning mate rials to test your fire detection devices Contact your alarm installer to discuss safe methods to test your system System Maintenance Under normal use your system requires virtually no maintenance other than regular testing It is recom mended that the standby battery be changed every three years 25 UM616 626 KEY ACCESS PROGRAMMING Several control panel features can be programmed quickly on the keypad without entering any program ming addresses or section numbers Select one key access programming mode by pressing ENTER followed by master or user code 1 Then press the single key listed below correspond ing to the feature you wish to activate Verify first with your installer that all of the features listed below have been programmed and activated on your con trol panel Press ENTER or CLEAR to exit key 9 Auto arming time program Key 9 flashes Enter two digits 00 to 23 for hours 2 digits 00 to 59 for minutes Press ENTER mem Panel time Key flashes Enter two digits 00 to 23 for hours 2 d
8. each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements Having and Practicing an Escape Plan There often may be very little time between detection of a fire and the time that it becomes deadly This interval may be as little as one or two minutes Advance warning of a fire may be wasted unless the family has planned in advance for a rapid exit from their residence Notes 1 Plan and practice for fire conditions with the focus on rapid exit from the residence 2 Drills should be held so that all family members know what to do 3 Each person should plan for the possibility that an exit out of the bedroom window may be necessary An exit out of the residence that does not require the opening of a bedroom door is essential Provision for the Disabled For special circumstances where life safety of some occupant s depends upon prompt rescue by others the fire warning system includes a means of prompt 24 UM616 626 automatic notification to those who are to be depended upon for the rescue Testing your System It is recommend that your system be tested once a week Contact your monitoring station BEFORE and AFTER testing Burglar Alarm Testing With the system disarmed and the READY light on activate motion detectors walk in protected area Open and close protected doors Observe the zone light It should come on following
9. an rein state the latest zone bypass instructions saved in memory Press BYP while in manual bypass arm ing mode and the previous bypass status will be reestablished This eliminates the need to enter the same bypass information every time you arm Control panel software versions prior to 2 00 12 UM616 626 5 AUTO BYPASS Away arming AWAY CODE Control panel software versions prior to 2 00 If you want to arm the system without manually enter ing zones to be bypassed on the keypad use Away auto bypass feature AWAY ACCESS CODE should be keyed in The control panel will automatically bypass any open zones after the exit delay terminates and the system will be armed The READY light does not have to be on but all open zones must be bypass enabled If any zones have been left open the BYP light will illu minate to indicate that zones have automatically been bypassed The fire zone cannot be bypassed FORCE Away arming Away CODE Control panel software versions 2 00 and beyond To arm the system rapidly without waiting for the READY light use Force Away arming away should be pressed followed by a valid access code Once the exit delay expires any open zones will not be considered activated by the panel Open zones will not be protect ed and will not generate an alarm or prevent arming These Away zones will be activated and therefore protected as soon
10. and for the zone connected to this keypad Each keypad must be programmed inde pendently PANEL BUZZER MUTE Key 9 Turns keypad sounder and OFF intermittent beep means is activat ed and keypad sounder is OFF Depress for 2 seconds to disable TROUBLE DISPLAY and TROUBLE MEMORY 10 different trouble conditions can be displayed on your keypad When a trouble condition occurs the TRBL key on your keypad illuminates and if programmed by your installer the keypad sounder will beep When oower supply failure trouble occurs the TRBL key flashes rapidly Press on this key and it flashes indi cating that your panel is in trouble display mode Control panel software versions prior to 2 00 Keys that illuminate in trouble display mode tell you which trouble conditions are taking place and or are Control panel software versions 2 00 and beyond 19 UM616 626 in memory Pressing on any key except 2 will return the keypad to normal zone display Trouble conditions will remain in trouble memory Pressing on the 2 key displays current trouble conditions Pressing CLEAR will erase trouble condi tions in memory Control panel software versions 2 00 and beyond Keys that illuminate in trouble display mode indicate the trouble conditions currently taking place Press on any key to return keypad to normal zone display Key 1 battery low battery If battery is n
11. d will not flash but will be con stantly illuminated 16 UM616 626 Note System A codes can stop sirens coming from System B zones and vice versa but will not disarm a system that is in alarm Pressing key 10 activates one key full arming When partitioning is enabled System A and B will be armed when key 10 is pressed Pressing key stay 11 activates one key Stay arming When partitioning is enabled System A is armed by pressing key stay 11 PS1 Bedside remote module Pressing any one of the three keys of this module will arm or disarm the system in Stay mode when par titioning is not activated Please note that if the sys tem is in entry delay or if an alarm is in progress for your protection the panel can only be disarmed from a keypad Pressing any two PS1 keys simultaneous ly will generate a panic alarm Your installer can also adjust the PS1 s illumination level and mute the buzzer as required Alarm Memory The memory light on your keypad will illumi nate if any alarm situations take place while your sys tem is armed A record of all alarm situations that occur is stored in memory After disarming the sys tem pressing once on the mem key brings up the zones that were open during the last alarm period 17 UM616 626 Programmable output Not only does your Esprit control panel provide top security it also offers you total convenience Your installer
12. de LED flashes At the end of the exit delay period the system will return to Stay arming mode B fast exit and regular arm key 10 arm Press key 10 for two seconds The system will switch to regular arming keys 11 and 12 flash with an exit delay LED flashes At the end of the exit delay period the system is regular armed 10 UM616 626 On control panel models 728 728 EXPRESS and 738 EXPRESS using software version 2 1X keys indicated will not flash but will be constantly illuminated Software versions 2 2X onward keys indicated do not illuminate However if system is Stay armed STAY key will illuminate Key switch Push button Arming Your system can include a key switch or push button that arms disarms the system This arming method is particularly useful when installed in a master bed room making system arming and disarming conve nient and accessible The beautifully styled Esprit PS1 bedside remote has been specifically designed for this application and includes a panic zone If an alarm is generated in your system or a zone that has not been defined as a Stay zone is opened after panel arming the system can only be disarmed from a keypad if keyswitch is defined as Stay arm ing using an access code Please ask your installer for more information 4 MANUAL BYPASS arming BYP CODE Arms the system while bypa
13. dual area is armed if either System A or System B is armed and disarmed only when both systems are disarmed Control panel software versions 2 00 and beyond 15 UM616 626 A zone belonging to a common area is a zone that is armed only when both systems are armed and disarmed if System A or System is disarmed Once zones have been assigned to either System A or System B code definition also programmed by the installer determines which access codes can arm System A zones as well as which codes can arm System B zones Codes can also be given access to both systems When the READY light is on entering a code that can access both systems will arm both System A and System B The stay and away keys will flash indicating the panel s armed status Entering this code when the panel is armed will disarm both systems To arm disarm each system separately Press Stay a valid access code to arm disarm System A Valid access code System A code or code with access to both systems When the stay key flashes this indicates System armed status Press AWAY a valid access code to arm disarm System B Valid access code System B code or code with access to both systems When the Away key flashes this indicates System B s armed status On control panel models 728 728 EXPRESS and 738 EXPRESS using software versions 2 1X onward keys indicate
14. eys 4 and 6 simultaneously for 2 sec will generate a panic 2 or if programmed a auxiliary alarm Pressing keys 7 and 9 simulta neously for 2 sec will generate a panic 3 or if pro grammed fire alarm 14 UM616 626 Based on your needs your installer can program these panic zones to generate audible alarms sirens or bells or silent alarms both of which also can be sent directly to your central security station The 3 dif ferent panic zones can also communicate specific messages to your monitoring station i e pressing panic 1 means call the police pressing panic 2 means call an ambulance pressing panic 3 means call the fire department Ask your installer for the exact definition of your panel s panic alarms DISARMING THE SYSTEM without partitioning Enter the area using the designated entry exit door s The keypad sounder emits a constant tone to remind you to disarm your system Enter your user code on the keypad before the entry time expires If you make a mistake while entering this code press CLEAR and re enter it The ARMED light will go off and the sounder will stop SYSTEM ARMING DISARMING with partitioning Zones can be divided into two systems Based on your requirements the installer designates which zones belong to System A or System B both sys tems dual area or are not given a system assign ment common area A zone belonging to a
15. g is activated Arms system A only when partitioning is enabled 1 and 3 Police or Silent Audible Not Used 4 and 6 Auxiliary or Silent Audible Not Used 7 and 9 Fire or Silent O Audible Not Used Both keys must be depressed at the same time for 2 seconds Armed LED will flash The PGM Programmable Output function if applicable is and is activated by SYSTEM TIMES Entering and exiting your premises is permitted through doors that you and your installer have determined You have one exit time and up to two individual entry times i e Zone 1 Front door delay 1 30 sec Zone 7 Garage door delay 2 90 sec You have seconds to EXIT your premises 32 UM616 626 Your Entry delay 1 is may enter through zone seconds and you Your Entry delay 2 is may enter through zone seconds and you Your siren if activated by an alarm will sound for minutes OTHER INFORMATION This alarm system was installed on By Service is provided by Tel Your monitoring station s telephone number is Your account number is Your alarm transformer location is and isoncircuit UL verified compatibility of the 616 626 with Esprit models 708 728 728 EXPRESS 738 738 EXPRESS 748 748ES and SRI 18 Look for and 09 marks on products Only products bearing those marks are UL and ULC listed 33 UM616 626 Programmable ch
16. gram your panel to recognize and control 2 separate systems by activating the panel s partitioning feature When partitioning is activated each zone can be defined as belonging to System A System B both systems dual area or no system assignment common area User access codes can also be programmed to arm or dis arm one system or both systems simultaneously Your keypad can display the status of both systems In partitioning mode when System A is armed the stay key flashes If System is armed the away key flashes If both systems are armed both of these keys will be flashing On control panel models 728 728 EXPRESS and 738 EXPRESS using software versions 2 1X onward keys indicated will not flash but will be constantly illuminated Code priority When deciding who should have access to your security system control panel please keep in mind that each user code can be assigned a different code priority by your installer Code priority determines the level of security access each user will have and which features and functions they can activate Control panel software versions 2 00 and beyond 4 UM616 626 User Codes 01 16 or 01 48 on control panels soft ware version 3 00 and beyond can be programmed by your installer to arm disarm the system activate stay or Away arming and zone bypassing These codes can also be designated to arm disarm only System A zones only System B zones or both sy
17. he monitoring station Check with your installer to see if this option is active on your system Deleting a user code Pressing ENTER master code code location 01 48 to be erased 2 key ENTER Press CLEAR to exit programming mode Note Do not clear master code ARMING THE SYSTEM without partitioning The Esprit can be armed in 5 different ways designed to cover a wide variety of security situations We suggest that you familiarize yourself with all 5 arming procedures so that you can take full advantage of your system 1 REGULAR system arming used for normal day to day system operation The keypad s green READY light must be on in 7 UM616 626 order to arm the system This light will only illuminate if all zones are closed All doors and windows must be closed and there can be no movement in areas monitored by motion detectors Once the READY light is on enter your user code If you make a mis take entering your code the keypad sounder END REJECTION beep will let you know Just press CLEAR and re enter the code When you have correctly entered your user code the red ARMED light will come on and you will hear the keypad CONFIRMATION beep The READY light will flash and the keypad will beep if programmed dur ing the exit delay period Note The last 10 seconds the beep will be faster stay and Away keys will flash Your installer will program exit delay dura
18. hone line monitor Key 10 illuminates if the panel detects the loss of the telephone line Key 11 Fire trouble If the fire zone is cut the fire zone key and trouble key 11 will illuminate Most of these trouble conditions will be programmed by your installer to be reported directly to your securi 22 UM616 626 ty company Please make sure to contact your alarm company however to ensure that repairs are imme diately made to your security system Fire Alarm Operation Alarm Upon a Fire Alarm the bell siren will operate in pulse mode Silence Reset To silence or reset a fire alarm enter a valid user code Note IF A FIRE CONDITION EXISTS FOLLOW YOUR EVACUATION PLAN IMMEDIATELY If there is no fire condition contact your moni toring company without delay to avoid an unnecessary response Fire Safety in the Home Reasonable fire safety can be achieved by following a three point program 1 Minimizing fire hazards 2 Providing a fire warning system 3 Having and practicing an escape plan Minimizing Fire Hazards The three traditional fire killers are 1 Smoking in bed 2 Leaving children home alone 3 Cleaning with flammable liquids such as gasoline 23 UM616 626 Providing a Fire Warning System Household fires are especially dangerous at night Fires produce smoke and deadly gases that can overcome occupants while they sleep To warn against fire smoke detectors should be installed out side of
19. igits 00 to 59 for minutes Press ENTER BYP Test report If programmed by your installer this sends a test report code to the monitoring station Control panel software versions 2 00 and beyond Control panel software versions prior to 2 00 26 UM616 626 TRBL Call Espload via telephone If programmed by your installer this initiates communication to the central monitoring sta tion computer using Espload software away Answer Espload This feature initiates modem communication between your panel and a computer running Espload software The ADP 1 adapter can also be used stay Cancel communication attempts Stops calls from to Espload When communicating with Espload it is impossible to enter programming mode 27 IMPORTANT UM616 626 Keep this information in a secure location ZONE DESCRIPTION PARTITIONING ACTIVATED Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Yes No 28 SYSTEM 24 Bypass A B Enabled J 0 O J B J 0 O O O J 0 ZONE DESCRIPTION PARTITIONING Yes SYSTEM ACTIVATED A B UM616 626 24 Bypass Hr Enabled Zone 13 U Zone 14 0 0o Zone 15 21 2 16 U Zone 17 O Zone 18 E
20. ime zones Press any key for 3 seconds to activate intermittent beeps or de activate chime zones continuous beeps Use key 8 to chime program keypad zone READY Green LED must be ON all zones closed to regular arm system When it flashes exit delay is in progress ARMED Red LED illuminates when system is armed Key ON TROUBLE DISPLAY 1 No battery Low battery 7 Communicator fail report 2 Power failure 8 Timer lost 3 AC fail 9 Tamper or zone wiring fail 10 Telephone line monitor 11 Fire trouble 4 No bell 5 Bell output limit 6 Aux power output To program or change time Press ENTER master code MEM 00 23 hours 00 59 minutes ENTER CLEAR UM6 16 626 Press for 3 sec to enable intermittent beep or disable continuous beep keypad buzzer total muting LE J FAST ARM key Press for 2 sec and system arms automatically No code required Enabled by installer 2 7 Activates STAY arming stay on the premises but still be protected STAY partial arming permits movement in pre selected unarmed zones CODE PARTITIONED SYSTEMS System A arm disarm key Display ast STAY ARM key Press for 2 sec and system stay arms automatically No code required Enabled by installer 2 CODE NO PARTITION Software versions prior to 2 00 AWAY auto bypass arming Versions 2 00 and beyond AWAY
21. ity system is clearly and simply displayed on the Esprit keypad The keypad diagram at the end of of this manual provides you with an excellent introduction to the roles of the keypad function keys on both the Esprit 616 and 626 keypads Individual zone key lights communicate the status of the zones in your system If the zone light is off the status in that zone is normal If the zone light is on constant light this means the zone is open If the zone light is flashing this means that there is a zone wiring problem which will be automatically commu nicated to your security company Listen Every time a key is pressed it illuminates and the key pad beeps 0 5 second tone to show that the entry has been recognized When you enter information on the keypad it will guide you with beep tones that com municate acceptance or rejection of your entries You should be familiar with these two keypad beep tones Keypad beep tones CONFIRMATION beep When an operation i e arm ing disarming is successfully entered on the keypad or when the system switches to a new status mode the sounder produces an intermittent beep tone beep When the system reverts to previous status or when an operation is incorrectly 3 UM616 626 entered on the keypad the sounder emits a contin uous beep tone PARTITIONING not available on all models Based on your instructions your installer can pro
22. le for any direct or indirect damages loss of anticipated profits loss of time or any other losses incurred by the buyer in con nection with the purchase installation operation or failure of this product Paradox Security Systems Graphic Dept PRINTED IN CANADA
23. ot connected to control panel or if it is at low capacity key 1 illuminates This means that the battery connected to panel should be replaced because it can no longer provide adequate back up current in the event of a power failure Trouble indicator 1 will also illuminate if battery voltage drops to 10 5 volts while panel is running on battery power with no AC Key 2 Power failure Control panel software versions 1 4 and beyond If AC power is not being supplied to the panel and or the power supply is unable to charge the battery and or the power supply voltage exceeds 14 9 volts key 2 will illuminate Power failure can be excluded from key TRBL display by your installer When a power supply failure trouble occurs TRBL key flashes rapidly 20 UM616 626 Key 3 AC power failure Control panel software versions prior to 1 4 If AC power is not being supplied to the control panel key 3 will illuminate AC trouble can be excluded from keypad trouble display by your alarm installer Key 4 Bell disconnect If a bell or siren is not connected to the bell siren out put this is indicated by the illumination of key 4 in trouble display mode Key 5 Maximum bell current If key 5 illuminates it indicates that the processor has recognized that the bell siren output current exceeds 3A This causes automatic shutdown of the bell output Once the problem is corrected power will automatically be restored
24. s tems by your installer Programming User Codes In addition to the master code the Esprit control panel can be programmed to accept up to 8 16 or 48 user codes depending on the control panel You can choose to use either 4 or 6 digit access codes with your system 6 digit codes are considered more diffi cult to crack and are therefore seen as more secure If however ease of recall is your priority then 4 digit access codes can be programmed instead Once your codes are entered your panel will store them even after total AC and battery failure Note Never select a code that is too simple or too obvious your telephone number street address or codes such as 1234 since these codes are used as defaults by many manufacturers Your installer will program the Esprit to accept 4 or 6 digit codes and also assigns code definitions to all access codes To create or modify access codes fol low the steps indicated on the next page The master code or user 01 code must be used to enter pro gramming mode to program user codes 5 UM616 626 Each access code is made up of 4 or 6 digits pro grammed by your installer The master code 474747 and user codes are identified by a 2 digit code number CODE CODE CODE CODE CODE CODE Master 00 User 17 17 User 34 34 User 1 01 User 18 18 User 35 35 User 2 02 User 19 19 User 36 36 User 3 03 User 20 20 User 37 37 User 4 04 User 21 21 User 38 38 User 5 05 User 22 22 U
25. ser 39 39 User 6 06 User 23 23 User 40 40 User 7 07 User 24 24 User 41 41 8 08 User 25 25 User 42 42 9 09 User 26 26 User 43 43 10 10 User 27 27 User 44 44 User 11 11 User 28 28 User 45 45 User 12 12 User 29 29 User 46 46 User 13 13 User 30 30 User 47 47 User 14 14 User 31 31 User 48 48 User 15 15 User 32 32 User 16 16 User 33 33 Creating User Codes 1 Press ENTER your master code 474747 or user 1 code You will hear the CONFIRMATION beep and the ENTER key will flash to show you that the panel is ready to accept your code number entries 2 Enter the two digit code number 01 16 or 01 48 for the user code you wish to program or 00 to change the master code You will hear the con FIRMATION beep and the ENTER key will stay 6 UM616 626 3 Key in 4 or 6 digits of the user code number and press ENTER The CONFIRMATION beep will be heard again The ENTER key will flash A four or six digit user code has been entered into memory You may continue programming other user codes or press CLEAR to exit programming mode Note 2 0 key flashes if location is empty no code programmed Duress code applicable for software version 3 10 The last user code user 48 can be programmed to report a duress code If you are forced to arm or disarm your system under threat a duress code can be entered in the key sequence to produce a silent alarm at t
26. ssing defective zones and or zones you wish to leave open Note When you bypass a zone it is no longer mon itored by the security system It will not generate an alarm on the control panel You might not wish to arm the entire system when for example workers are renovating part of your 11 UM616 626 house or for any other reason you need to leave a zone open If a component of your security system is damaged it can also be bypassed until repairs are made Manual bypass arming instructs the control panel to ignore zones that you designate open so that the rest of the system can still be armed Based on your instructions only zones that your installer has programmed bypass enabled can be bypassed during manual bypass arming auto bypass Away arming or Stay arming Please note that the fire zone can not be bypassed Press the bypass BYP key followed by your ACCESS CODE You now in bypass mode The BYP key will be illuminated and if zones are currently bypassed they will illuminate as well Enter the key numbers corresponding to the zones you wish to bypass Press again on the key if you wish to undo a zone selection If you have entered the correct zone bypass informa tion press ENTER The BYP key light will remain indicating that zones have been bypassed If you make an error entering zone numbers press CLEAR By using the bypass recall feature you c
27. tion based on the time you require to safely exit the pro tected area once the system is armed On control panel models 728 728 EXPRESS and 738 EXPRESS using software version 2 1X keys indicated will not flash but will be constantly illuminated Software versions 2 2X onward keys indicated do not illuminate 2 STAY arming partial system arming Stay arming allows you to remain in the protected area while partially arming the system This means that you can stay in and move around your home or commercial building while certain designated zones are armed You might choose to have entry exit points like doors or win 8 Stay CODE OR KEY 11 UM616 626 dows protected or the basement or perhaps all the zones on the perimeter of your home or establishment Based on your instructions your installer programs the control panel to arm certain zones in Stay arm ing mode These programmed Stay zones will arm on Stay mode and can only be changed by your installer Please remember that fire zones cannot be bypassed Using this convenient feature you can Stay arm the system and then leave the premises while others remain in the protected area Pressing STAY ACCESS CODE or KEY STAY 11 see below on the keypad activates Stay arming com mand Stay arming can also be activated by a key switch refer to key switch push button arming 3 ONE KEY arming One
28. to the bell siren circuit Key 6 Maximum auxiliary current Key 6 illumination indicates that the processor has recognized auxiliary output current exceeds 1A This causes automatic shutdown of the auxiliary output Once the problem is corrected power will automati cally be restored to the auxiliary output This output powers such devices as motion detectors and acces sory modules Key 7 Communicator report failure If your control panel cannot communicate with the central monitoring station key 7 illuminates 21 UM616 626 Key 8 Timer loss If the system timer is not functioning usually after total battery and AC power failure key 8 illuminates The timer should be reprogrammed after total power loss To reprogram the timer control panel software ver sions prior to 2 00 Press ENTER master code user 1 code Then enter 2 digits 00 to 23 for hours followed by 2 digits 00 to 59 for minutes Press ENTER twice If trouble key 8 is still illuminat ed press TRBL CLEAR after programming the time To reprogram the timer control panel software ver sions 2 00 and beyond Press ENTER master code user 1 code Key men flashes Then enter 2 digits 00 to 23 for hours followed by 2 dig its 00 to 59 for minutes Press ENTER Key 9 Tamper zone wiring failure Key 9 if illuminated means that there is a wiring problem in one of your protected zones Key 10 Telep
29. touch system arming no code required Key 10 regular arming When the light is on pressing key 10 steadi ly for 2 seconds automatically full arms the system if programmed No user code is required This feature can be used to allow specified individuals like service personnel i e cleaners maintenance to arm the sys tem when leaving the protected area without giving them access to any other panel operations Key stay 11 Stay arming Please refer to Stay arming section above for a full explanation of this feature There is no need to wait 9 UM616 626 for the READY light before Stay arming however all zones that have been programmed by your installer to arm in Stay mode must be closed no move ment in the zones when arming the system Pressing key stay 11 steadily for 2 seconds will automatically Stay arm the system Double Stay arming During the exit delay pressing stay 11 again will switch any delay 1 or delay 2 zones to instant zones 24 hour Stay zones follow Stay zones and instant Stay zones are not affected Full system arming cancels double stay arming Fast exit Exit while the system is armed in Stay mode key stav 11 is flashing A fast exit and stay key 11 To exit the premises and remain Stay armed press key stay 11 for two seconds The system will switch to exit delay mo