Emerson CF960BS 00 Owner's Manual
Contents
1. 3 14 Screw 5 32 32 x 5 16 4 15 Pendant Wood Small 16 Pendant Wood Large 17 Coupling Chain 2 18 Cover Ceiling 670169 34 670169 30 670169 15 19 Cover Coupling 761860 18 761860 6 761860 3 20 Housing Upper 762334 762334 1 762334 2 21 Adapter Coupling 762331 762331 762331 22 Blade Set of 6 762329 762329 1 762329 2 23 Flange Set of 6 762333 762333 1 762333 2 24 Plate Mounting 762327 762327 762327 25 Adapter Plate Light 762384 762384 1 762384 2 26 Harness Wiring 762337 2 762337 1 762337 27 Light Fixture Assembly 762366 762366 1 762366 2 28 Flood Lamp 75W Long Neck Halogen PAR 30 Owner s Manual BP7268 1 BP7268 1 BP7268 1 S EMERSON Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant e St Louis MO 63136 Part No F40BP72680001 Printed in Taiwan 05 03 Form No BP7268 1
2. LIII 4 WARNING HANGER BALL Figure 8 DOWNROD ASSEMBLY The outlet box must be securely anchored and capable of withstanding a load of at least 50 Ibs Wiring Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician A WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is ground ed contact a licensed electrician for advice as it must be grounded for safe operation 1 Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply this may be a bare wire or wire with green colored insulation Figure 9 Securely connect the wires using wire connector supplied NOTE CEILING COVER OMITTED FOR CLARITY BLACK AND BLUE FAN WIRES GROUND WIRE LISTED WIRE CONNECTOR 3 WHITE SUPPLY NEUTRAL GREEN WIRE GROUND FROM HANGER BRACKET WHITE FAN WIRE GREN WIRE BLACK SUPPLY HOT GROUND FROM pee HANGER BALL THREADED STUD 2 Figure 9 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 9 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplie
3. fuse box or circuit breaker before trouble shooting your fan TROUBLE Trouble Shooting PROBABLE CAUSE SUGGESTED REMEDY 1 Fan will not start Fuse or circuit breaker blown Loose power line connections to the fan Reversing switch in neutral position Check main and branch circuit fuses or circuit breakers Check line wire connections to the fan WARNING Make sure main power is turned OFF Make sure reversing switch position is all the way to one side 2 Fan sounds noisy Blades not attached to fan Loose screws in motor housing Screws securing fan blade flanges to motor hub are loose Motor noise caused by solid state variable speed control Screws holding blades to flanges are loose Attach blades to fan before operating Check to make sure all screws in motor housing are snug not over tight Check to make sure the screws which attach the fan flanges to the motor hub are tight Some fan motors are sensitive to signals from Solid State variable speed controls If Solid State Control is used and motor noise results choose an alternative control method Tighten screws securely 3 Fan wobbles excessively Setscrew in motor coupling is loose Setscrew in hanger ball downrod assembly is loose Screws securing fan blade flanges to motor are loose Hanger bracket and or ceiling outlet box is not securely fa
4. BUSHING Q KNURLED NUT 4 Figure 20 Position the switch chain bushing in the hole in the light adapter plate Figure 19 and secure using the knurled nut SWITCH CHAIN LD BUSHING Q KNURLED NUT n REVERSING supplied the wiring harness included as part of Figure 19 ile a the light fixture assembly must be removed and be reinstalled in the light adapter plate This Section 5 Position the two switches of the harness assembly in the mounting bracket the small switch light switch installs in the left hole and the larger switch speed control switch installs in the right hole Figure 20 Secure the switches using the appropriate knurled nuts Pass the speed control switch chain through the chain bushing If desired tape the other switch chain to the adapter plate as shown tape not supplied CAPACITOR LIGHT ADAPTER LATE SPEED CONTROL WITCH CHAIN BUSHING KNURLED NUT MOUNTING BRACKET Remove one protective covering from the two sided foam tape supplied and apply the foam tape to the capacitor Remove the remaining protective covering and then firmly press the capacitor onto the adapter plate Figure 20 7 Position the reversing switch in the slot in the adapter plate and secure using two screws Figure 19 IMPORTANT LIGHT FIXTURE ASSEMBLY REVERSING ad Figure 18 The next three steps step 8 9 and 10 are to be perf
5. F YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center e To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Company 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by e Repairs by persons not authorized by Emerson Company e Use of parts or accessories not authorized by Emerson Company e Mishandling improper installation modifications or damage to your ceiling fan while in your possession or e Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implie
6. IGHT FIXTURE Figure 21 12 Position the light adapter plate over the light fixture mounting plate The adapter plate switches must be located in the recessed portion of the mounting plate Figure 15 Align the holes in the adapter plate with the holes in the mounting plate and install four 5 32 32 x 5 16 Phillips flat head screws supplied Figure 22 13 Cut the speed control switch pull chain to your desired length optional Connect the wood pendant supplied to the pull chain by sliding the wood pendant small hole first onto the pull chain Figure 22 Then attach a chain coupling supplied to the end of the chain and allow the pendant to slide down over the coupling E Re XN wNNN Nt YS S S ADAPTER PLATE 7X 5132 32 x 5 16 PHILLIPS NS SWITCHES FLAT HEAD SCREW 4 WOOD PENDANT Figure 22 j lt CHAIN COUPLING Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the speed control pull chain switch Figure 23 The operating sequence is as follows THREE SPEED 1st Pull HIGH 2nd Pull Medium 3rd Pull Low 4th Pull OFF LIGHT CONTROL ITCH SPEED CONTROL SWITCI SWITCH REVERSING SWITCH Figure 23 3 If airflow is desired in opposite direction turn your fan off and wait for the blades
7. RACKET S i DOWNROD ASSEMBLY FAN BLADES Assembling and Hanging the Ceiling Fan 1 Remove the fan motor assembly from the protec tive plastic bag and then carefully remove the foam shipping material from between the fan motor and the upper housing Figure 1 FAN MOTOR FAN MOTOR HOUSING Figure 1 2 Place the fan motor assembly in the lower styro foam pad with the top of the motor facing up The WS MOTOR COUPLING ag Figure 3 Sie lower styrofoam pad serves as a holder for the fan motor assembly during the first stages of assembly 3 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 2 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in step 6 PIN HANGER BALL SI Figure 2 SETSCREW 4 Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the Figure 4 downrod Remove the upper setscrew from the motor coupling Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 3 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole nea
8. READ AND SAVE THESE INSTRUCTIONS WIND AMMER Ceiling Fan Model No Owner s Manual CF960CK 00 CFS6OWB 00 Net Weight 27 6 Lbs CFS60BS 00 LIMITED WARRANTY What The Warranty Covers This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is As it applies to the motor this warranty will last for thirty years from the date you purchased your ceiling fan All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Company Do To Correct Problems Emerson will replace a defective Emerson Air Comfort Ceiling Fan motor blade component or other accessory at no charge to you If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided Emerson will refund the actual purchase price of your fan WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON How Can You Get Service YOU MUST HAVE PROOF O
9. al Is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Tools Needed for Assembly One Phillips head screwdriver One stepladder One 1 4 blade screwdriver One wire stripper Three wire connectors supplied MATERIALS Wiring outlet box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of the following size Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 A WARNING Before assembly your ceiling fan refer to Wiring Your Ceiling Fan section for proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted A WARNING Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could
10. d Figure 9 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box A WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket Figure 9 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 10 5 Secure the ceiling cover in place by sliding 8 lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 10 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod 6 Figure 12 THREADED STUD 8 LOCKWASHER KNURLED oa 8 Figure 10 4y WARNING To avoid possible fire or shock make sure that the CEILING COVER electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling Final Assembly of the Ceiling Fan 1 Mount the blade flange to the blade using three 3 16 24 x 5 16 slotted Phillips head screws and three M5 flat washers supplied Figure 11 Repeat this procedure for the re
11. d warranty of merchantability or fitness for a particular purpose are voided when e The original purchaser or user ceases to own the product or e The fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Company REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Part No F40BP72680001 Form No BP7268 1 A WARNING WARNING To avoid fire shock and serious personal injury follow these instructions Safety Instructions Read your owner s manual carefully and keep it for future reference B
12. ed Make sure the connector latch closes properly 7 Figure 16 IMPORTANT If you intend to install your ceiling fan without using the light fixture supplied with the fan or if you are going to use a different Emerson light fixture with your fan proceed to Installation of Light Adapter Plate Section on page 8 RECESSED PORTION OF MOUNTING PLATE PROVIDES CLEARANCE FOR LIGH FIXTURE SWITCHES LIGHT FIXTURE MOUNTING PLATE mi LIGHT FIXTURE 3 R ASSEMBLY MOTOR CONNECTOR LIGHT FIXTURE CONNECTOR Figure 15 A WARNING To avoid possible fire or shock make sure that the electrical wires are not pinched between the light fixture assembly and the mounting plate 6 Position the light fixture assembly over the light fixture mounting plate The light fixture switches must be located in the recessed portion of the mounting plate Figure 15 Align the holes in the light fixture with the holes in the mounting plate and install four 5 32 32 x 5 16 Phillips flat head screws Figure 16 Carefully screw in the 75 watt halogen flood lamp supplied 7 Cut the speed control switch and light control switch pull chains to your desired length optional Connect the wood pendant supplied to one pull chain by sliding the wood pendant small hole first onto the pull chain Figure 16 Then attach a chain coupling supplied to the end of the chain and allow the pendant to s
13. efore servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing Do not put anything into the fan blades while they are turning Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades All wiring must satisfy National and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt The downrod
14. furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades The light fixture supplied with the ceiling fan is designed to use a long neck 75 watt maximum halogen flood lamp Do not install a lamp that exceeds 75 watts Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage WARNING To Reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use This Manu
15. lide down over the coupling Repeat this procedure for the other pull chain Y LIGHT FIXTURE N SWITCHES e WOOD PENDANT CHAIN COUPLING Installation of Light Adapter Plate IMPORTANT Perform the procedures in this Section ONLY if you intent to install your ceiling fan without using the light fixture supplied with the fan or if you are going to use a different Emerson light fixture with your fan NOTE In order to use the light adapter plate contains the procedures to accomplish this 1 Figure 17 2 DISCONNECT THE LIGHT FIXTURE CONNECTOR WIRING FROM THE WIRING HARNESS CONNECTOR Disconnect the light fixture connector from the wiring harness connector Figure 17 Unscrew the knurled nuts from the light switch and the speed control switch The knurled nuts are not interchangeable keep them with their respective switch Gently pry the capacitor secured by two sided tape from the light fixture assembly CAPACITOR LIGHT FIXTURE U ASSEMBLY SPEED CONTROL SWITCH KNURLED NUT HARNESS CONNECTOR LIGHT SWITCH KNURLED NUT Remove and retain the two screws securing the 6 reversing switch to the light fixture Figure 18 Remove and retain the harness assembly Remove the knurled nut from one of the switch chain bushings Figure 18 Retain the knurled nut and bushing for installation in the next step SWITCH CHAIN BS
16. maining five blades 3 16 24 x 5 16 SLOTTED PHILLIPS HEAD SCREW 3 M5 FLAT WASHER 3 Ng BLADE 2 Install one blade assembly to the motor hub using two 1 4 20 x 1 2 Phillips oval head screws Figure 12 Repeat this procedure for the remaining five blade assemblies BLADE ASSEMBLY 1 4 20 x 1 2 PHILLIPS OVAL HEAD SCREW 2 PER BLADE FLANGE M Partially install two 3 16 24 x 1 4 Phillips round head screws in two of the tapped holes in the coupling adapter Figure 13 Leave two or three threads untightened COUPLING ADAPTER Sy 3 16 24 x 1 4 PHILLIPS ROUND HEAD SCREWS 2 Figure 13 4 Position the keyhole slots in the light fixture mount ing plate over the two screws in the coupling adapter Figure 14 Rotate the mounting plate clockwise to engage the slots under the screw heads then install a 3 16 24 x 1 4 Phillips round head screw in the remaining tapped hole in the coupling adapter Tighten the two screws securing the keyhole slots LIGHT FIXTURE MOUNTING PLATE PA INSTALL 3 16 24 x 1 4 PHILLIPS ROUND HEAD SCREW Ry TIGHTEN TWO 3 16 24 x 1 4 PHILLIPS ROUND HEAD SCREWS LD ROTATE MOUNTING PLATE CLOCKWISE Figure 14 5 Engage the connector from the light fixture assembly with the motor connector Figure 15 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engag
17. ormed ONLY if you are installing an optional Emerson light fixture If you are installing your fan without a light fixture proceed to step 11 8 Remove the screw plug Figure 20 from the bottom of the light adapter plate and install your optional Emerson light fixture in accordance with the light fixture Owner s Manual Carefully cut the blue wire going to the light switch Strip off 1 2 inch of insulation and connect this blue wire to the blue wire from the light fixture Figure 21 using a wire connector supplied 10 Carefully cut the white wire going to the two wire connector Strip off 1 2 inch of insulation and connect this white wire to the white wire from the light fixture Figure 21 using a wire connector supplied Engage the connector from the light adapter plate with the connector from the motor assembly Figure 15 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the connector latch closes properly 11 4 WARNING To avoid possible fire or shock make sure that the electrical wires are not pinched between the light adapter plate and the mounting plate TWO WIRE CONNECTOR CUT WHITE WIRE HERE LIGHT SWITCH 4 CONNECT TO WHITE WIRE FROM LIGHT N M TE FIXTURE posera S O E E CUT BLUE WIRE ESS gt HERE X O ee LZ 000000009 CONNECT TO BLUE WIRE A FROM L
18. ose setscrew could create fan wobble 2 WARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling A WARNING To reduce the risk of fire electric shock or personal an injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician in in doubt DOWNROD CEILING COVER 9 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 7 al Ss N i l x OUTLET Figure 5 1 7 i 5 an a aK i 2 7 The fan comes with blue black and white leads that are 80 long Before installing the fan measure up approximately 6 to 9 inches above the top of hanger the ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from the end of TWO SCREWS leads SUPPLIED WITH e OUTLET BOX HANGER Wa Your new ceiling fan will require a grounded 120 BRACKET volts AC 60 Hz 15 amp electrical supply line If your fan is to replace an existing ceiling light fix ture turn electricity off at the main fuse box at this Figure 7 time and remove the existing light fixture 10 Ca
19. r the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed Reinstall the upper setscrew in the motor coupling Figure 3 Check that the two lower setscrews are tightened securely NOTE The setscrews must be properly installed as described above or fan wobble could result 4 A WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling Q gt ane 5 Make sure the grommet is properly installed in the coupling cover then slide the coupling cover on the downrod until it rests on the motor housing Place the ceiling cover over the downrod Be sure that the ceiling cover and the coupling cover are both oriented correctly Figure 4 CEILING COVER N COUPLING COVER 6 Reinstall the hanger ball Figure 5 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A lo
20. refully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 8 Be 4 WARNING sure the groove in the ball is lined up with tab on Turning off wall switch is not sufficient To avoid the hanger bracket Figure 7 possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and A WARNING Local codes and the ceiling fan must be properly i grounded as a precaution against possible electrical Hanger bracket must seat firmly against outlet box If shock the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall 4 WARNING To avoid fire or shock follow all wiring instructions WARNING carefully Any electrical work not described in these An instructions should be done or approved by a Failure to seat tab in groove could cause damage to licensed electrician electrical wires and possible shock or fire hazard 4 WARNING A WARNING The fan must be hung with at least 7 of clearance To avoid possible fire or shock do not pinch wires from floor to blades Figure 6 between the hanger ball downrod assembly and hanger bracket SUPPLY WIRES AND FAN WIRES OMITTED f FOR CLARITY i NOTE CEILING COVER Pa f Dn l 1 ee HANGER BRACKET Figure 6 ZZZ FLOOR
21. result in personal injury or property damage 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration Fan motor assembly One light fixture assembly Six fan blades Six blade flanges One ceiling cover One hanger ball downrod assembly One hanger bracket One coupling cover One light fixture mounting plate One PAR 30 75 watt halogen flood lamp One light adapter plate One loose parts bag containing 1 Nineteen 3 16 24 x 5 16 slotted Phillips head blade screws Nineteen M5 flat washers One large wood pendant One small wood pendant Two couplings Thirteen 1 4 20 x 1 2 Phillips oval head flange screws Three wire connectors Two threaded studs Two 8 lockwashers TATOO Te FroaAanNn TOD oO ON Oo WP 10 Two knurled knobs 11 One clevis pin 12 One hairpin clip 13 Four 5 32 32 x 5 16 Phillips flat head screws 14 Three 3 16 24 x 1 4 Phillips round head screws 15 One two sided foam tape NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding FAN MOTOR ASSEMBLY LIGHT FIXTURE BLADE ASSEMBLY FLANGES Etar Loose CESS SS y EE PARTS BAG COUPLING E COVER LK CEILING HANGER BALL eS HANGER Ne EK B
22. stened Fan blades out of balance Tighten setscrew securely in the motor coupling Tighten the setscrew in the hanger ball downrod assembly Check to be sure screws which attach the fan blade flanges to the motor are tight Tighten the hanger bracket screws to the outlet box and or secure outlet box Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation Repair Parts Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION e PART NUMBER e PART DESCRIPTION e NAME OF ITEM e MODEL NUMBER For repair parts phone 1 800 654 3545 lt E Z SF GLY ELGSE 11 Repair Parts Listing Model No Key No Description CF960CK00 CF960WBO00 CF960BS00 Hanger Ball Assembly 761655 23 761655 20 761655 17 Consisting of 1 Hanger Bracket _ 2 Hanger Ball 3 Downrod Parts Bag Containing 762367 762367 1 762367 2 4 Wire Connector 3 5 Threaded Stud 2 6 Lockwasher 8 2 7 Knurled Knob 2 8 Clip Hairpin 9 Pin Clevis 10 Screw 3 16 24 x 5 16 19 11 Flat Washer M5 19 12 Screw 1 4 20 x 1 2 13 13 Screw 3 16 24 x 1 4
23. to stop turning then slide the reversing switch to the opposite position and turn the fan on again The fan blades will turn in the opposite direction and reverse airflow 4 Check the operation of the light fixture by gently pulling on the light control pull chain switch Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish A WARNING Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock Accessories 1 Ceiling Fan Light Controls see store or catalog 2 Downrod Extension Kits see store or catalog 3 Ceiling Fan Light Kits see store or catalog A WARNING The use of any other control not specifically approved for this fan could result in fire shock and personal injury A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Company Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage ay WARNI NG For your own safety turn off power at