Contents
1. Battery Monitoring For Business Critical Continuity Alber BDSi Battery Monitoring System For UPS Battery Cabinet Integration Alber technologies by Emerson Network Power are designed to prevent battery failure optimize useful battery life reduce Key Features of Alber BDSI maintenance costs and increase safety Flexibility The Alber BDSi is designed specifically for factory integration into Liebert UPS battery cabinets for 12 and 16 volt battery Web based monitoring interface allows applications A factory installed monitor continuously scans easy user access to data and reports and reports all critical battery parameters providing detailed A single controller unit communicates reports that allow proactive battery management The result with up to six DCM LM units for a reliable effective system that is efficient to deploy monitoring of a total of six battery cabinets Factory installed or field installation kits available for Liebert UPS battery cabinets Higher Availability Factory installation and testing ensures proper operation at start up Data tracking and detailed reports allow analysis for proactive prevention of battery failure Lowest Total Cost of Ownership Replace batteries when they are at the end of their service life not by calculations that could result in premature or late replacement Complete factory installation eliminates requirement of field installation Alber BDSi Battery Mon
2. er European Headquarters Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco PD Italy 39 049 9719 111 Phone 39 049 5841 257 FAX Emerson Network Power Asia Pacific 29 F The Orient Square Building F Ortigas Jr Road Ortigas Center Pasig City 1605 Philippines 63 26876615 63 2 730 9572 FAX liebert com 24x 7 Tech Support 800 222 5877 Phone 614 841 6755 outside U S While every precaution has been taken to ensure accuracy and completeness in this literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2011 Liebert Corporation All rights reserved throughout the world Specifications subject to change without notice All names referred to are trademarks or registered trademarks of their respective owners Liebert is a registered trademark of the Liebert Corporation SL 29206 R08 11 Printed in USA EmersonNetworkPower com Racks amp Integrated Cabinets
3. ication options are by Ethernet network card RS 232 or dial up modem Liebert NXL battery cabinet with Alber BDSi Battery Monitor First battery e e l cabinet center with Controller and Liebert APM battery DCM LM Additional battery cabinet cabinet with DCM LM right with DCM LM only top and Controller bottom BDSi Specifications Sealed batteries are sensitive to temperature and float voltage settings Monitoring these conditions can considerably extend useful battery life A Liebert battery monitor provides the user with detailed information allowing for cost savings by optimizing useful battery life Instead of waiting for an inevitable failure or replacing batteries prematurely to prevent problems you can continue to utilize your batteries longer and with confidence by knowing their true internal condition It is essential to detect deterioration at an early stage to prevent catastrophic failures when dealing with sealed batteries This makes measurement technology the most important consideration when selecting a monitoring system Other battery monitors internal ohmic readings become inconsistent as the UPS load varies because of variations in AC ripple on the battery The Alb r DC resistance test method is not influenced by ripple and thus provides data that is repeatable and reflects the true condition of the battery a Less than 2 0 amps at 115 VAC 10 60Hz or 230 VAC 10 60Hz a Configura
4. itoring provides real time information for proactive battery management Ideally Suited for Liebert UPS external battery cabinets o Liebert NXL o Liebert NX o Liebert APM O Liebert 16V battery cabinet p A S EMERSON Simple hardware configuration User friendly software provides easy to interpret data Battery Monitor Data Manager BMDM Computer Software is included with every system With the software you can program thresholds view graphs and trends to identify failing batteries set alarms notifications and distribute reports The reports have built in decision support that analyzes the data and provides suggestions for the best corrective action STATION 122 ta Set Detail Graph tor 06 01 2002 2B lej x Easy to interpret graphs make data understandable and manageable The Alber BDSi system consists of two units a Controller and a Data Collector Module Load Module DCM LM The Alber BDSi Controller stores the data provides alarms power and communication connections The DCM LM unit collects individual cell data and performs the resistance test The first battery cabinet includes both an Alber BDSi Controller and Alber BDSi DCM LM Each additional battery cabinet uses only an Alber BDSi DCM LM unit linked to the single Controller Unit in the first battery cabinet A Controller can communicate with up to six DCM LM units or battery cabinets Commun
5. m x 5 09 H 129 3mm a ULlisted m CEapproved Emerson Network Power a business of Emerson NYSE EMR is the global leader in enabling Business Critical Continuity from grid to chip for telecommunication networks data centers health care and industrial facilities Emerson Network Power provides innovative solutions and expertise in areas including AC and DC power and precision cooling systems embedded computing and power integrated racks and enclosures power switching and controls monitoring and connectivity All solutions are supported globally by local Emerson Network Power service technicians Liebert AC power precision cooling and monitoring products and services from Emerson Network Power deliver Efficiency Without Compromise by helping customers optimize their data center infrastructure to reduce costs and deliver high availability Emerson Network Power The global leader in enabling Business Critical Continuity ACPower Embedded Computing Outside Plant Power Switching amp Controls Services z Surge Protection Connectivity Embedded Power DCPower Infrastructure Management amp Monitoring Precision Cooling Emerson Network Power Liebert Corporation World Headquarters 1050 Dearborn Drive P O Box 29186 Columbus Ohio 43229 United States Of America 800 877 9222 Phone U S amp Canada Only 614 888 0246 Phone Outside U S 614 841 6022 FAX Emerson Network Pow
6. tions 40 12 volt or 30 16 volt jars per string Remote alarm reset User supplied 12 to 32V signal Less than 50ma a Momentarily applying voltage initiates the reset action m 24VAC power For up to six Data Collector Module Units a Alarm contacts Two Form C 2A at 30VDC One for critical alarm one for maintenance alarm Modbus protocol ASCII to PC and SNMP via Ethernet m Local LAN port RS 232 DB 9 connector rear panel a LAN port RJ 45 m RJ 11 Telco line internal modem optional USB for local PCV connection m SRAM 8 MB nonvolatile memory for all configuration settings and test data m Holds up to one year s worth of data a Flash memory for firmware upgrades Temperature range 5 C to 40 C 41 F to 104 F a Indoor use only Number of cell channels Up to six strings of 40 12 volt jars or 30 16 volt jars a Cell voltage 0 16V 0 15 of reading 4mV a Current transducer is required a Cell Resistance 0 32000 1 5 of reading 54 m Transducer accuracy affects overall current reading accuracy a String voltage 0 400V 0 1 of reading 1V 0 600V 0 2 of reading m Float Current 0 5000mA 0 1 of reading Optional ce a Discharge Current 0 600V 0 1 of reading 6A 0 1000V 0 1 of reading 10A a Controller unit 19 5 W 495 3mm x 11 81 D 299 9mm x 3 38 H 85 9mm a Data Collector Module unit 19 5 W 495 3mm x 12 06 D 306 3m
Download Pdf Manuals
Related Search
Related Contents
LAUFBAND BEDIENUNGSANLEITUNG KONSOLE Samsung 24" LED Монитор серии I 2493HM Инструкция по использованию QuatroProbe User Manual Télécharger le Dossier de Presse DBO mètre 6 postes Modèle BODtrak II chèque transport - Comité Ile de France de natation Jean-Luc Arnaud analyse spatiale, cartographie et histoire urbaine FreeFlow®-Druckserver Systemhandbuch Copyright © All rights reserved.