1. wiring and wire connectors close to the downrod and slide the coupling cover over the wires NOTE Be sure light kit assembly wires are positioned in the dimpled wireway of the upper housing to avoid pinching of the wires during installation of coupling cover 4 WARNING To avoid fire or electrical shock be careful not to pinch wires between the housing and coupling cover CAUTION Before installing and tightening the screws be sure there are no wires pinched between the light kit assembly motor assembly and coupling cover 7 Reinstall the three coupling cover screws to secure the coupling cover Figure 7 COUPLING COVER Figure 7 REINSTALL COUPLING COVER SCREWS 3 Assembly and Installation CAUTION To reduce the risk of a WARNING electric shock disconnect the Do not install or use the light fixture electrical supply circuit to the fan if any part is missing or damaged before installing light kit assembly Contact your dealer for replacement Check to see that you have received the following parts A WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker before wiring NOTE If you are uncertain of part description refer to exploded view illustration a Light Kit Assembly b Four 25 Watt Candelabra Bulbs c One Loose Parts Bag Containing Four 8 32 x 8mm Pan Head Screws 1 spare
2. BULB 4 Figure 3 A WARNING To avoid possible fire hazard do not exceed four 25 watt candelabra base light bulbs Installation for Ceiling Fan CF921 1 Remove the three coupling cover screws and slide the coupling cover up the downrod for installation of light kit assembly Figure 4 Retain the three screws for later installation of coupling cover COUPLING COVER SCREWS 3 REALO g g COUPLING COVER UPPER FAN MOTOR Figure 4 2 Position the light kit assembly so that the opening of the light kit assembly slides through the downrod Align the mounting holes of the light kit assembly to the motor assembly Figure 5 NOTE Be sure the light kit assembly connector is located close to the motor assembly connector for ease of installation 3 Install the light kit assembly to the motor assembly using three light kit assembly mounting screws Figure 5 LIGHT KIT ASSEMBLY LIGHT KIT ASSEMBLY SCREW 3 UPPER FAN MOTOR ASSEMBLY Figure 5 4 Securely connect the light kit assembly connector to the motor assembly connector Figure 5 5 Screw the four 25 watt candelabra base bulbs supplied into the light kit assembly sockets Figure 6 A WARNING To avoid possible fire hazard do not exceed four 25 watt candelabra base light bulbs FAN MOTOR ASSEMBLY CONNECTOR 25 WATT ASSEMBLY CANDELABRA CONNECTOR BULB 4 Figure 6 6 Carefully tuck all
3. IDENTAL AND CONSEQUENTIAL DAMAGES Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly How State Law Relates To The Warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state cA we aL EMERSON Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No BP7431 1 Form No F40BP74310001 Printed in China 11 11 READ AND SAVE THESE INSTRUCTIONS Ceiling Fan Accent Light Fixture Owner s Manual Model Number AL100 Four 25 Watt Candelabra Base Bulbs Net Weight 0 62 Lbs Form No F40BP74310001 Part No BP7431 1 ETL Model No AL100 a WARNING Trouble Shooting Safety Instructions To avoid fire shock and serious personal injury follow all 1 The Lamp Will 1 Wiring not complete 1 Check all wiring connections instructions carefully Not Illuminate to light kit and fan 1 Read your Owner s Manual carefully before installing the light i 2 Light bulbs do not light 2 Check and replace light bulbs fixture Retain
4. LIMITED WARRANTY What The Warranty Covers All products covered by this Owner s Manual are warranted against all defects in workmanship and materials You must be the original purchaser or user of the product to be covered What The Period Of Coverage Is All components are covered by this warranty for one year from the date you purchased your light fixture ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR What Will Emerson Electric Co Do To Correct Problems Emerson Electric Co will replace a defective Emerson Light Fixture at no charge to you WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO How Can You Get Service YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE LIGHT FIXTURE TO OBTAIN LIMITED WARRANTY SERVICE KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE You can return the product to our factory or to your nearest authorized service center e To return the product to the factory obtain a return authorization and service identification tag by writing to Air Comfort Products Division of Emerson Electric Co 8100 W Florissant Ave St Louis MO 63136 Include all model numbers shown on the product with your request e To return the product to an authorized service center call 1 800 654 3545 for
5. Owner s Manual for future reference g i N 2 Be careful of the fan and blades when cleaning painting or working near the fan Before installing or servicing the light fixture or ceiling fan switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel 3 Do not exceed the wattage indicated on fixture Four 25 watt candelabra base light bulbs ADDITIONAL SAFETY INSTRUCTIONS FOR INSTALLATION 1 To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring 2 The installation is to be in accordance with the National Electrical Code ANSI NFPA 70 2008 and Local Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 Make certain no bare wires are exposed outside the wire connectors 4 All wiring must conform to national and local electrical codes 5 Follow the recommended instructions for the proper method of wiring your new light fixture If you feel you do not have enough electrical wiring knowledge or experience have your light fixture installed by a licensed electrician Any electrical work not described i
6. n this manual should be performed by a licensed electrician WARNING To reduce the risk of possible fire and electrical shock install only on Emerson Models CF921 and CF901 Ceiling Fans Installation for Ceiling Fan CF901 1 Position the light kit assembly so that the opening of the light kit assembly slides through the downrod Align the female connector of the light kit assembly with the male connector of the motor housing assembly Figure 1 2 Align the mounting holes of the light kit assembly to the motor assembly Figure 1 LIGHT KIT ASSEMBLY LIGHT KIT ASSEMBLY SCREW 3 UPPER FAN MOTOR ASSEMBLY MOTOR ASSEMBLY CONNECTOR Figure 1 NOTE Be sure the light kit assembly connector is located close to the motor assembly connector for ease of installation 3 Install the light kit assembly to the motor assembly using three light kit assembly mounting screws Figure 1 4 Securely connect the light kit assembly connector to the motor assembly connector Figure 1 5 For storage of excess wire gather the extra light kit assembly wire and carefully tuck into the access hole of the light kit assembly Figure 2 a EXCESS LIGHT KIT ASSEMBLY WIRE ACCESS HOLE OF LIGHT KIT ASSEMBLY Figure 2 6 Screw the four 25 watt candelabra base bulbs supplied into the light kit assembly sockets Figure 3 FAN MOTOR ASSEMBLY LIGHT KIT ASSEMBLY 25 WATT CANDELABRA
7. the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Light Fixture should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by e Repairs by persons not authorized by Emerson Electric Co e Use of parts or accessories not authorized by Emerson Electric Co e Mishandling improper installation modifications or damage to your light fixture while in your possession or e Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when e The original purchaser or user ceases to own the product or e The ceiling fan is moved from its original point of installation This warranty is only valid within the 50 states of the United States and the District of Columbia No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND INCLUDING INC