Home

Electrolux E36GC75GSS User's Manual

image

Contents

1. Procedure 1 Remove electrical access panel from rear 6 Place plastic inserts in upper and lower of cooktop drilled holes to protect cord 2 Disconnect power cord and ground wires 7 Knot power cord to secure into place then remove from cooktop 8 Reconnect power cord and ground wires 3 Locate area for new hole to be drilled 1 2 9 Fill remaining hole surrounding power cord in from back edge on underside of cooktop with silicone caulk then mark hole location using an awl or punch 49 Cover both sides of original hole with two 4 Use 3 4 drill bit to drill new hole completely layers of aluminum tape through 11 Screw electrical access panel back in place 5 Route power cord wires through hole rd The Electrolux Group USA 250 Bobby Jones Expressway Augusta GA 30907 1 877 4electrolux 1 877 435 3287 electroluxicon com a inter ae paar een fi a ay ai pe CANADA e 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 electroluxicon ca specifications or discontinue models without notice GC_PCRELO 03 08 2008 Electrolux Home Products Inc Printed in the U S A
2. one 9 500 BTU Precision Burner and one 5 000 BTU Precision Burner Specifications subject to change Gas Thru Glass Cooktop Remove the grates to reveal the smooth flat ceramic glass surface that now makes cleanup easier in this traditionally difficult area of the cooktop Beveled Front Controls Ergonomically designed for visibility and comfort Large professional style knobs are clearly scaled to eliminate guesswork while cooking Optional black knobs available UNI NN NWN Designed for the well lived home W 6 Sealed Burners Yes 18 000 450 14 000 13 000 9 500 5 000 750 Yes Yes 3 6 2 1 1 1 1 Included Included Included Optional Optional Optional 7 3 4 35 7 8 25 3 4 Right Rear Left Rear Included 120V 1 2W 60Hz 15A 0 001 Included No Yes 113 Lbs 118 Lbs When replacing an existing cooktop with countertop cutout deeper than 7 1 4 and less than 8 1 2 order free Depth Adjustment Filler Kit For use on adequately wired 120V dedicated circuit having 2 wire service with a separate ground wire Appliance must be grounded for safe operation Not approved to be used over any Electrolux ICON Single Wall Oven Approved to be used in combination with an Electrolux ICON Downdraft Vent Proper combination installation will require cooktop power cord to be relocated NOTE Always consult local and or national electric and gas cod
3. breaks such as short section of nonmetallic duct should be used in areas of extreme cold e For most efficient airflow exhaust use a straight run or as few elbows as possible e Cold weather installations should have additional backdraft damper installed e Installing a Downdraft Vent in combination with any gas cooking surface will affect optimum burner efficiency e Downdraft Vents can NOT be used in combination with any cooktop backsplash Note For planning purposes only Refer to Product Installation Guide on the web at electroluxicon com for detailed instructions High standards of quality at Electrolux Home Products Inc mean we are constantly working to improve our products We reserve the right to change specifications or discontinue models without notice Printed in the U S A 30 amp 36 Gas Slide ln CARR Power Cord Relocati ior To install an Electrolux ICON Gas Slide In Cooktop in combination with an Electrolux ICON Downdraft Vent cooktop power cord MUST be relocated to underside of unit Gas Slide In Cooktops requiring this procedure are E30GC74GPS E86GC75DSS E86GC75ESS E386GC75GSS E86GC76EPS and E86GC76GPS Please have qualified electrician perform following rewiring procedure in accordance with local and national electric codes Tools amp Materials Phillios Head Screwdriver Hammer Awl or Punch Drill with 3 4 drill bit 2 Plastic Inserts 73209 2470 Silicone Caulk and Aluminum Tape
4. ICON A Electrolux WY AW e W n NV o Q a 36 GAS SLIDE IN COOKTOP Configuration FEATURES Black Ceramic Glass Cooktop Surface Large Professional Skirted Knobs with Bezel Min 2 Max Dual Ring Sealed Burner BTU Sealed Power Burner BTU Sealed Burner BTU Sealed Precision Burner BTU Linear Flow Burner Valves Electronic Ignition Continuous Grates osa a G ACCESSORIES SO 9 re Wok Ring Simmer Plate 9 Stainless Steel Backsplash 903048 9010 Black Knobs Kit 903049 9120 Depth Adjustment Filler Kit 903051 9010 SPECIFICATIONS Overall Exterior Dimensions Height Width Depth Gas Inlet Location Power Supply Location Lp Conversion Kit Voltage Rating Min 2 Max Burners Burner configuration includes two versatile Min 2 Max sealed burners delivering anywhere from 18 000 to 450 BTUs Thanks to the double ring configuration you can simmer sauces or bring water to a boil You decide the level of heat output by a simple turn of the knob Connected Load kW Rating 120 Volts Electrical Cable Approved for Single Oven Combination Installation Approved for Downdraft Vent Combination Installation Product Weight Shipping Weight Approx Six Sealed Burners Designed for cooking multiple dishes at varying temperatures on a single cooktop Includes two 18 000 450 BTU Min 2 Max burners one 14 000 BTU Power Burner one 13 000 BTU Burner
5. Specifications page and on web Proper combination installation will require cooktop power cord to be relocated to underside of unit For details refer to 30 amp 36 Gas Slide In Cooktop Power Cord Relocation Instructions on web Note For planning purposes only Refer to Product Installation Guide on the web at electroluxicon com for detailed instructions Optional Accessories e When replacing an existing cooktop with countertop cutout deeper than 7 1 4 and less than 8 1 2 order free Depth Adjustment Filler Kit 903051 9010 e 9 Stainless Steel Backsplash 903048 9010 e Black Knobs Kit 903049 91 20 rd The Electrolux Group USA 250 Bobby Jones Expressway Augusta GA 30907 1 877 4electrolux 1 877 435 3287 electroluxicon com CANADA e 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 electroluxicon ca E36GC75GSS 05 08 High standards of quality at Electrolux Home Products Inc mean we are constantly working to improve our products We reserve the right to change specifications or discontinue models without notice 2008 Electrolux Home Products Inc Printed in the U S A A Way Dk AW an a i Slide In Cooktop Downdraft Vent YW VEN WN WEAN VAN k N 1 Countertop Preparation Countertop Preparation for 30 amp 36 Slide In Cooktop Downdraft Vent Installation For detailed cooktop and downdraft vent installation specifications ref
6. e on web e Voltage Rating 120V 60Hz 15 Amps e Connected Load kW Rating 120 Volts 1 0kW For use on adequately wired 120V dedicated circuit having 2 wire service with a separate ground wire Appliance must be grounded for safe operation rd The Electrolux Group USA 250 Bobby Jones Expressway Augusta GA 30907 1 877 4electrolux 1 877 435 3287 electroluxicon com CANADA e 5855 Terry Fox Way Mississauga ON L5V 3E4 1 800 265 8352 electroluxicon ca SIC_DDV_PREP 05 08 2008 Electrolux Home Products Inc Opening for downdraft vent E36DD75ESS 36 Cooktop Cutout Dimensions 36 Cooktops A B C D E E36EC75DSS 356 35 6 22 25 he E36EC75ESS 356 35 e 22 25 he E36EC75HSS 356 35 y6 22 253e E36GC75DSS 356 35 e 22 253e 35 e 35 y6 22 25 3e 356 35 6 22 25 13e 35 16 35 ye 22 25 M6 35 e 35 e 22 25 Sie E36GC75ESS E36GC75GSS E36GC76EPS E36GC76GPS e Amps 120 Volts 8 0 Amps e Vent unit outside of building only e Vent must be installed in vertical orientation only e 1 600 CFM remote exhaust blower part number 5304444802 included with vent shipped in separate box e Do not use flexible duct Round duct instead of rectangular duct recommended especially when elbows are required e When multiple elbows are necessary ensure a minimum of 24 of straight duct between any two elbows e Thermal
7. er to model specific product page and installation guide on web 1 countertop overhang E30DD75ESS 30 Cooktop Cutout Dimensions B c D E Proper combination installation will require cooktop power cord to be relocated to underside of unit For details refer to 30 amp 36 Gas Slide In Cooktop Power Cord Relocation Instructions page Slide In Cooktop Downdraft Vent Countertop Preparation Specifications e For detailed Slide In Cooktop installation refer to model specific product page and installation guide on web Plan installation so that all required minimum clearances between cooktop overhead cabinets and adjacent vertical walls are provided e Position cooktop vent cutout so all required minimum clearances are met e Minimum flat countertop area must meet or exceed combined overall width and depth as shown e Separate circuits required for cooktop and vent Refer to product specific electrical specifications e Always consult local and or national electric codes Check local building codes for installation requirements as they may vary per locale e Proper combination installation will require 30 amp 36 Gas Slide In Cooktop power cord to be relocated to underside of unit For details refer to 30 amp 36 Gas Slide In Cooktop Power Cord Relocation Instructions on web Downdraft Vent Specifications e For detailed Downdraft Vent installations refer to model specific product page and installation guid
8. es Refer to Product Installation Guide for detailed installation instructions on the web at electroluxicon com electroluxicon com g A N Gas Slide In Cooktop AAL AANA E36GC75GSS ALL RALL Ni WAY y AYA x a AN K AY W AN AN WA X AW N LA W Y WAN Y y AS g iA a X Di KN B b T 4 AN z max 357 cabinet i depth Optional 9 stainless steel backsplash 1 min recommended distance between rear edge of cutout and nearest combustible surface above countertop Ree aa m 25 min bo 1 Ve oA max 4 x 4 opening to route gas supply 36 Gas Slide In Cooktop Specifications e Product Weight 113 Lbs e Voltage Rating 120V 1 2W 60 Hz 15 Amp e Connected Load kW Rating 120 Volts 0 001 kW For use on adequately wired 120V dedicated circuit having 2 wire service with a separate ground wire Appliance must be grounded for safe operation e Amps 120 Volts 0 008 Amps e Always consult local and or national electric and gas codes e Cooktop ships with 3 4 factory regulator e Lp conversion kit supplied e Respect critical dimensions as noted for proper installation of cooktop e Overhead cabinetry should not exceed a 13 maximum depth e Allow 30 minimum clearance between top of cooktop and bottom of unprotected wood or metal overhead cabinetry e Absolute minimum horizontal distance between ove
9. rhead cabinets installed to either side of appliance must be no less than maximum width of appliance e Allow 24 minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1 8 flame retardant millboard covered with not less than No 28 MGS sheet steel 0 015 stainless steel 0 024 aluminum or 0 020 copper ee 25 Ya 30 min for unprotected cabinet 24 min for protected surface 7 fa 7 min to nearest combustible wall Both cutout dimensions are critical to proper cooktop installation Due to variations in countertop materials it is recommended to undercut finished dimension 35 15 16 and adjust upon installation of cooktop e Allow 1 minimum clearance between rear edge of cutout and nearest combustible surface above countertop e Allow 7 minimum clearance from edge of cooktop to nearest combustible wall on either side of unit e It is recommended that drawers not be used beneath cooktop e To reduce risk of fire when using overhead cabinetry install vent hood that projects horizontally a recommended minimum of 7 beyond bottom of cabinets e Gas Slide In Cooktop model E86GC75GSS is NOT approved to be used over any Electrolux ICON Single Wall Oven e Gas Slide In Cooktop model E86GC75GSS without optional backsplash is approved to be used in combination with an Electrolux ICON Downdraft Vent Refer to Slide In Cooktoo Downaraft Vent Countertop Preparation