1. ATING INSTRUCTIONS e Press ON OFF without weight on platform Display will show PE5R briefly and then 0 0 ounces When using Adapter if Display fluctuates between and 0 0 reverse Adapter in wall outlet YOU CAN NOW WEIGH OBJECTS ON SCALE Press ZERO TO RETURN DISPLAY TO 0 0 oz BEFORE EACH WEIGHING AND BEFORE PLACING MATERIAL ON PLATFORM Arrow in readout indicates mode displayed Press RATE ZONE until desired rate mode is indicated If the 1st Class package letter is over 13 oz the scale will default to Priority Mail When using Priority Mail a destination zone must be entered The display will read Ent Press ENTER and then select the destination zone by toggling with the RATE ZONE key Press the Enter key when the correct zone is located You will need an Official National Zone Chart from the United States Postal Service visit your local post office or their web site http postcalc usps gov zonecharts to ensure the correct zone is being used NOTE After Scale has been turned off and then again turned on display will return to 0 0 in ounce mode Press ON OFF to turn off Scale ZERO ADJUST TARE ZERO may be used to return Display to zero ZERO is used to tare or offset weight e Place empty container on scale Press ZERO e Place material to be weighed in container Display will show NET WEIGHT of material in container Press ZERO each time additiona
2. ion Attach proof of purchase to your defective product along with your name address daytime telephone number and description of the problem Carefully package the product and send with shipping and insurance prepaid to Pelstar LLC Attention R A Repair Department 7400 W 100th Place Bridgeview IL 60455 If your scale is not covered by warranty or has been damaged an estimate of repair costs or replacement costs will be provided to you for approval prior to servicing or replacing pelouze Technical Service Returns 800 638 3722 Customer Service 800 654 8330 Postal Rate Increase 888 807 2253 www Pelouze com Pelstar LLC Bridgeview Illinois 60455 All rights reserved Pelouze is a registered trademark of Pelstar LLC Made in China to our exact specifications 03 03 59341
3. l material is added to container Total not to exceed 5 Ib capacity of Scale aesa appearing in display indicates minus weight Press ZERO to return display to zero NOTE TO CLEAR ANY MODE OR TO RETURN TO ZERO REMOVE MATERIAL AND PRESS ZERO Anonmachinable surcharge will apply to letters weighing under 1 oz that are smaller than 5 L x 3 2 H or larger than 11 2 L x 6 s H There are additional criteria that will cause your letter to incur the nonmachinable surcharge Please consult your USPS Service Guide or www usps com for complete details 2 EASY TO READ DISPLAY 0 1 OZ CAPACITY 5 Ib x 0 1 oz Zz WEIGHT R 00 R isu express CAN MEX MAIL PRIORITY pelouze Rate Calculating moot PESR NOT LEGAL FOR TRADE FEATURES AUTOMATIC OFF Scale will automatically turn off after approximately 30 seconds of inactivity no weight change This prolongs Battery life To deactivate Automatic Off While scale is off PRESS and hold RATE ZONE While still holding RATE ZONE press ON OFF until SHOF appears briefly in Display and automatically goes into normal weighing mode To reactivate Automatic Off PRESS ON OFF to turn off scale Press ON OFF again to turn the scale back on and Automatic Off will be activated OVERLOAD WARNING appearing in the upper half of Display indicates you have exceeded Scale capacity LOW BATTERY WARNING Blinking bAtt appea
4. material or in workmanship exists customers sole remedy will be repair or replacement of scale at no charge Replacement will be made with a new or remanufactured product or component If the productis no longer available replacement may be made with a similar product of equal or greater value All parts including repaired and replaced parts are covered only for the original warranty period Who is Covered The original purchaser of the product must have proof of purchase to receive warranty service Pelstar dealers or retail stores selling Pelstar products do not have the right to alter or modify or any way change the terms and conditions of this warranty What is Excluded Your warranty does not cover obsolete dials or chips due to postal rate changes normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instruction abuse including tampering damage in transit or unauthorized repair or alternations Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province or jurisdiction to jurisdiction To get Warranty Service Make sure you keep your sales receipt or document showing proof of purchase Call 1 800 638 3722 to receive a return authorizat
5. pelouze ELECTRONIC WEIGHING INSTRUMENTS OPERATOR S MANUAL MODEL NO PE5R 5 Ib Capacity a TM Envelopes Small Packages Please take a few minutes to read this Operator s manual so that you can become acquainted with the proper usage and special features of your PELOUZE DIGITAL SCALE CONGRATULATIONS Thank you for selecting a Pelouze electronic weighing instrument With proper care and usage its loadcell technology should provide you with trouble free service We know you will be happy with your selection Its outstanding quality and dependability are backed by the reputation Pelouze Scales have earned since 1894 GENERAL INFORMATION MODEL PE5R operates on one 9V Battery or 120V AC Adapter Output 9V DC 100 mA Pelouze Model ADPT2 e If using Battery Battery compartment is located on underside of scale Connect battery accordingly e If using Adapter First plug into rear of scale then into wall outlet Peel off protective plastic foil on display Place scale on a vibration free level surface Replacement postal chip can be obtained from your dealer whenever postal rates change RATES CALCULATED US Destinations e 1st Class Mail up to 13 0z e Priority Mail from 13 oz to 5 Ibs consult your USPS rate guide for Priority rates under 13 oz Express Mail International Destinations Canada Airmail Letter Post to 4 Ibs e Mexico Airmail Letter Post to 4 Ibs OPER
6. ring on Display indicates low battery ERROR MESSAGES If the display shows Err1 The rate chip is missing damaged defective or inserted in the wrong direction Verify that the rate chip was inserted in the proper direction If this does not correct the error message return the scale for repair see Warranty for details If the display shows CNTO The scale s calibration needs to be restored Contact Pelouze Technical Support at 1 800 638 3722 for instructions CARE amp CLEANING Your PESR is a precision instrument engineered to give years of valuable service Care should be given to maintain its accuracy and appearance PROTECT YOUR SCALE FROM e Being Dropped Shock Loading e Excessive weight Extreme Temperatures e Liquid Spills e Other Abuses This scale is easily cleaned by wiping with a damp soft cloth and mild nonabrasive detergent SPECIFICATIONS DIMENSIONS 5 7 8 x 8 x 1 1 2 PLATFORM SIZE 5 7 8 x 5 7 8 CAPACITY 5 Ib x 0 1 oz MODEL NO PE5R POWER SOURCE 9V Battery or Pelouze ADPT2 Adapter with 120V AC 60Hz 3W input 9V DC 100mA Output mge 1 YEAR LIMITED WARRANTY What does this Warranty Cover Pelstar LLC scales are warranted from date of purchase against defects of materials or in workmanship for a period of 1 year If product fails to function properly return the product prepaid and properly packed to Pelstar If manufacturer determines that a defect of