Dimplex DX4130 User's Manual

image

Contents

1. 8 00AM 6 00PM Mon Fri 8 30AM 1 00PM Sat Millbrook House Grange Drive Customer helpline Tel 0845 600 5111 Hedge End Fax 01489 773053 Southampton e mail customer services glendimplex com SO30 2DF Republic of Ireland Tel 01 842 4833 C Glen Dimplex UK Ltd All rights reserved Material contained in this publication may not be reproduced in whole or part without the prior permission in writing from Glen Dimplex UK Limited
2. Hook wall box on to screw using keyhole slot provided 7 Mark position of remaining fixings remove box and complete fixing 8 Fix the wall box to the wall ensuring the drain hole is at the bottom 9 1 Cable entries are made to the base of the box using the holes provided 0 Connect circuit wiring to terminal block see Fig 2 OP N Neutral to load j 4 N Supply Neutral N N e SLI L D Earth terminal j SLI Supply to load L Supply live 11 Plug detector head into the back box socket Secure detector to wall box with screws provided and cover screws with screw caps Adjusting PIR Range 15M Limit the range and angle of detection as appropriate by adjusting the detector head and by using the lens masking plates provided Cut the appropriate segments from the lens mask to cover the area of the lens that requires masking A1 A2 A3 A4 Long Range 6 15 metres B1 B2 B3 B4 Inner Range 3 12 metres C1 C2 C3 C4 Short Range 0 3 metres 90 45 0 45 90 15m 12m 3m 3m 12m 15m 902 0 15m 15m 902 452 Masked Areas Masked Areas AC A4 A1 A2 A4 B3 B4 B1 B2 B4 C3 C4 C1 C2 C4 Testing 1 Set the light level 1 to maximum clockwise and the time on to minimum anti clockwise 2 Move in and out of detection pattern checking the PIR detector switches load on and then off Once the detection area has been set satisfactorily adjust the time blue knob to the desired level For your convenience op
3. G ox Dimplex Installation and Operating Instructions Passive Infra Red Detector Switch Model No DX4130 CE Issue 3 November 2006 Height Width Depth 130mm 85mm 145mm 130mm THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE IMPORTANT SAFETY ADVICE General The installation of this product should be carried out The Dimplex passive infra red detector switch has been designed to by a competent person or electrician in strict enable Dimplex Quartz and ceramic heaters or any other heater up to on 3kW It automatically switches the heater on and off depending on accordance of the current IEE Wiring Regulations AP heared Pon the heater is occupied P 9 The DX4130 is designed to be used in conjunction with Dimplex heaters up to 3kW electrical loading Features Only to be used on a 220 240Volt A C electricity supply e Time delay adjustment Electricity supply must be isolated before e Full 180 coverage over 15m if required commencement of installation e Size of detection area can be reduced Always isolate the detector switch and the heater 2ppipved oy eee ee ae from the electricity supply before undertaking any A and plug in detector lead to simplify installation maintenance work Must not be installed and used in the vicinity of a Contents bathroom or swimming pool X 1 Instruction sheet X 1 grey wall box with fixed terminal block X 1 PIR switch with pre wired plug in connection X 2 screw
4. itching capability Up to 3kW Operating Power 3kW Detection Range 15 metres maximum Detection Angle 180 Heater on time Adjustable to 10 seconds 60 seconds 3 5 minutes 6 minutes 9 minutes 12 minutes 13 5 minutes 16 minutes 21 minutes approximately IMPORTANT When unit is first connected to the mains the light will switch on even in daylight Allow unit to reset before testing After Sales Care Your product is guaranteed for one year from the date of purchase Within this period we undertake to repair or exchange this product free of charge subject to availability provided it has been installed and operated in accordance with these instructions Your rights under this guarantee are additional to your statutory rights which in turn are not affected by this guarantee Should you require after sales service you should contact the supplier through whom you purchased the product or contact our customer service help desk on 0845 600 5111 It would assist us if you can quote the model number series date of purchase and nature of the fault at the time of your call The customer service help desk will also be able to advise you should you need to purchase any spares Please do not return a faulty product to us in the first instance as this may result in loss or damage and delay in providing you with a satisfactory service Please retain your receipt as proof of purchase Glen Dimplex UK Ltd UK customer helpline
5. s to affix PIR switch to wall box X 3 screw caps X 1 lens mask Installation Please also refer to the IMPORTANT SAFETY ADVICE Before undertaking installation work ensure the electricity supply is disconnected from any relevant fixed wiring Supply cable is not provided with this product and it should therefore be installed by a competent person or electrician This PIR detector must be used on an A C supply only Dimplex Quartz and ceramic heaters operate by emitting radiant heat within a specific area or zone The beam of radiant heat will interfere with the correct performance of the PIR detector unless the PIR detector is mounted outside the throw of radiant heat It is therefore essential that the PIR detector is mounted as outlined below For installation of Quartz and ceramic heaters please refer to the relevant installation instructions The PIR should be positioned to cover the desired sensing area without obstruction avoiding the direct throw of the heater The PIR should be wired directly back to a type C MCB or 13 amp re wireable fuse The cable should not exceed 2 5mm Remove screws and disconnect the plug connecting the detector to the key box When removing the detector head the latch on plug should be released as indicated see Fig 1 salt ale cae Detector Head Plug Press Down Fig 1 Installation continued 5 Insert top screw into the wall allowing it to protrude by approximately 3mm 6
6. timum settings have been indicated 3 Ifthe unit does not operate refer to the check list and fault finding list Check List 1 Check the supply to the detector 2 Ifthe unit is being tested during daylight ensure that the photocell has been adjusted in accordance with point 1 in the Testing section 3 Check detector is connected to the heater correctly Fault Finding List Problem Solution The unit will not switch on e Check power is supplied to the unit e Check the plug in connection from the detector head is inserted in to the wall box correctly e Check to see that the lamps are fitted correctly to the heater s Unit is detecting at too long a range Check mounting height and adjust angle of the unit downwards to reduce range note the unit is designed to switch at a maximum of 15 metres with 170lb 77kg person walking at 90 to the unit Alternatively fit an appropriate mask IMPORTANT at 10 C this unit may detect in excess of 20 metres Unit switches on for no apparent e Check the unit is not sited near any vents or heating flues reason Infra red patterns are given off by electrical appliances NOTE to reduce sensitivity blank off areas C1 C2 C3 C4 of the lens mask Unit will not switch off e Are you standing by the detection zone Whilst you are moving in and out of the detection area the unit will continue to detect The heater on time is from the last moment detection was made Technical Specification Sw