Home

Cooper Lighting INVUE IMI-606 User's Manual

image

Contents

1. INV LJ Mast Arm Adapter INSTALLATION INSTRUCTIONS eheeto ere IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE RETAIN FOR FUTURE REFERENCE A WARNING Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing 4 Attach Housing to Mast Arm Adapter Remove the WIREWAY PLUG from the HOUSING Move the fixture leads aside so the THREADED RODS may be accessed through the fixture HOUSING See Figure 4a Attach the MAST ARM ADAPTER to the HOUSING by inserting the threaded studs into the fixture HOUSING Feed the fixture wires through the MAST ARM ADAPTER Slide the HOUSING over the threaded rods and secure it with the PLAIN WASHERS LOCK WASHERS and HEX NUTS See Figure 4b Torque HEX NUTS as follows Medium Icon ICM 450 in lbs Small Icon ICS 130 in lbs Risk of Personal Injury Wireway Plug Fixture may become damaged and or unstable if not installed properly Tighten all fixture components to their recommended torque values NOTE It may be helpful to use a deep socket when installing the HEX NUTS Re install the WIREWAY PLUG into the wireway in the HOUSING These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is desired to satis
2. READ CAREFULLY BEFORE INSTALLING FIXTURE 2 29104 nina RETAIN FOR FUTURE REFERENCE A WARNING Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing 6 Buttoning Up Re install the POWER SUPPLY TRAY to the HOUSING Connect the POWER CONNECTOR and OPTIC CONNECTOR Swing the POWER SUPPLY TRAY up and tighten the two THUMB SCREWS Re install the REFLECTOR to the HOUSING Connect the REFLECTOR CONNECTOR to the HOUSING Swing the REFLECTOR up until it is secured by the REFLECTOR TABS You will hear an audible click when the REFLECTOR TABS have properly engaged Close the fixture DOOR See Figure 6 You will hear two audible clicks when the two BUTTON LATCHES are properly engaged Re lamping the Fixture Disconnect the power to the fixture Open the DOOR by pressing both BUTTON LATCHES at the same time Remove the lamp by grasping it close to the base and install the new lamp Close the fixture DOOR You will hear two audible clicks when the two BUTTON LATCHES are properly engaged Reflector Power Supply Tray Outer Door These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest repre
3. INV LJ Mast Arm Adapter INSTALLATION INSTRUCTIONS __Sheet 1 F IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE 5 26 04 IMI 606 RETAIN FOR FUTURE REFERENCE General Upon receipt of fixture thoroughly inspect for any Safety This fixture must be wired in accordance with freight damage which should be brought to the attention of the national electrical code and applicable local codes the delivery carrier Compare the catalog description listed and ordinance Proper grounding is required to insure on the packing slip with the fixture label on the housing to personal safety Carefully observe grounding procedure assure you have received the correct merchandise All work should be done by an electrician WARNING Risk of Electric Shock Disconnect power at circuit breaker panel or fuse box before installing or servicing 1 Open the Door Press both BUTTON LATCHES at the same time and open the door See Figure 1 Button Latches Push to Open 2 Reflector Removal Press the two REFLECTOR TABS outward and swing the REFLECTOR down See Figure 2a and Figure 2b NOTE Disconnect REFLECTOR CONNECTOR from the HOUSING as shown in Figure 2c Reflector Tabs Fig 2a These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is
4. desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest representative COOPER Lighting Customer First Center 1121 Hwy 74 South Peachtree City GA 30269 IMI 606 AVU040954 INV LJ Mast Arm Adapter INSTALLATION INSTRUCTIONS __Sheet2 ers IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE a eaaet RETAIN FOR FUTURE REFERENCE A WARNING Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing Reflector Connector Reflector Fig 2b 3 Power Supply Tray Removal Unscrew the two THUMB SCREWS and swing the POWER SUPPLY TRAY down as shown in Figure 3a Disconnect the POWER CONNECTOR and the OPTIC CONNECTOR from HOUSING See Figure 3b The POWER SUPPLY TRAY can now be lifted off the bracket DES Power Connector GA X AAN S Optic Connector AN D Ex qa e Thumb Screws Fig 3a These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest representative COOPER Lighting Customer First Center 1121 Hwy 74 South Peachtree City GA 30269 Imi 6o6 AVU040954
5. fy a problem not covered sufficiently for user s purpose please contact your nearest representative COOPER Lighting Customer First Center 1121 Hwy 74 South Peachtree City GA 30269 IMI 606 Avu040954 INVUE Mast Arm Adapter INSTALLATION INSTRUCTIONS __Shecters IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE ann ae RETAIN FOR FUTURE REFERENCE A WARNING Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing 5 Slip the Assembly over the mast arm Secure Mast Arm Adapter to the mast arm with the four 4 3 8 16x3 8 Set Screws Drill a 3 8 hole through the mast arm and install the 3 8 carriage bolt and nut Use care in drilling hole so as not to damage electrical wires in the mast arm Make electrical connections in the Mast Arm Adapter Install the wire way door with two 2 6 32x3 8 screws See Figure 5 These instructions do not claim to cover all details or variations in the equipment procedure or process described nor to provide directions for meeting every possible contingency during installation operation or maintenance When additional information is desired to satisfy a problem not covered sufficiently for user s purpose please contact your nearest representative ae COOPER Lighting Customer First Center 1121 Hwy 74 South Peachtree City GA 30269 Imi 606 AVU040954 INV LJ Mast Arm Adapter INSTALLATION INSTRUCTIONS Sheets ers IMPORTANT
6. sentative COOPER Lighting Customer First Center 1121 Hwy 74 South Peachtree City GA 30269 IMi 606 AVU040954

Download Pdf Manuals

image

Related Search

Related Contents

NOTICE POOL CONTROL PH PLUS MOIN_ INJECT+  

Copyright © All rights reserved.
Failed to retrieve file