Cisco Systems uBR-E-16U Getting Started Guide

image

Contents

1. Upconverter 95804 Attenuator i Cable X A Note All upstream ports are light blue 5 Removing the Card To prevent the alarms from activating administratively shut down the card using the shutdown command in interface configuration mode before removing it from the chassis Step1 Make sure that you are properly grounded Step2 Disconnect all the cables from the cable interface line card Step3 Unscrew the captive installation screws on the faceplate Figure 4 Removing the Card from the Chassis 2 h 3 yy 95802 Ss S s S 7 ATIA A Step4 Grasp the handle and carefully pull the card out of its slot see Figure 4 Caution Always handle the cable interface line card by the carrier edges and handle never touch the card s components or connector pins Step5 Place the card on an antistatic surface with the component side facing up amp Note Ifthe card is being returned to the factory immediately place it in a static shielding bag and proper packaging for protection A Caution For proper cooling and airflow always install a line card cover in an empty line card slot Troubleshooting Check the following 1 Make sure that the card is securely seated in the chassis If the captive screws do not tighten all the way the card is not properly seated in the chassis or backplane Carefully pull the card h
2. line card with a card of a different type 4 Installing the Card Note The uBR E 16U line card is an entry level version of the uBR MC16U line card and fits only in the uBR7225VXR chassis Step1 Make sure that you are grounded Step2 Use both hands to grasp the line card by its metal carrier edges and align the line card with the slot guides component side up Step3 With the metal carrier aligned in the slot guides see Figure 1 briskly slide the card into the card slot until you feel it seat in the backplane connectors Step4 Tighten the captive screws X Note The captive screws provide grounding for the electromagnetic interference EMI shielding Figure 1 Installing the Card in the Chassis x Note The cable interface line card insertion and removal method is the same for all the Cisco uBR7200 series routers Cabling e Cisco uBR MC16U Green tabs e Cisco uBR E 16U Slate blue tabs e Cisco uBR MC16X Yellow tabs Figure 2 Cisco uBR MC16U oonan 95801 Cabling the Cisco uBR MC16U E 16U The Cisco uBR MC16U E 16U cable interface line card has an onboard upconverter To cable the card Step1 Connect the downstream cable to the downstream DS port The RF downstream port rings and end tabs are green for uBR MC16U see Figure 2 and slate blue for uBR E 16U Step2 Connect the upstream cables to the upstrea
3. afeafe CISCO Quick START GUIDE Installing Cisco uUBR MC16U X and uBR E 16U Cable Interface Line Cards Purpose Feature Description Prerequisites Installing the Card Removing the Card Troubleshooting Technical Specifications on Ooh WRN Related Documentation A Warning Only trained and qualified personnel should be allowed to install replace or service this product A Caution You must be properly grounded before handling this ESD sensitive product 1 Purpose This quick start guide shows you how to install a Cisco uBR MC16 cable interface line card in the Cisco uBR7200 series router 2 Feature Description The Cisco uBR MC16 cable interface line card improves RF performance supports spectrum management increases system performance and supports online insertion and removal OIR The line card is available in three configurations e Cisco uBR MC16U With an onboard upconverter and green end tabs e Cisco uBR E 16U With an onboard upconverter and slate blue end tabs e Cisco uBR MC16X Without an onboard upconverter and yellow end tabs 3 Prerequisites e The Cisco NPE 400 or the Cisco NPE G1 or the Cisco NPE G2 network processing engine must be used with this card e Ifyou are using the Cisco uBR MC16 line card to replace a different type of card you must reconfigure the MC16U X E card e We recommend that you reload a Cisco 7200 series router when replacing a cable interface
4. alfway out of the slot reinsert it and tighten the captive installation screws A b Ifa port is enabled but its corresponding enabled LED is still off check to see if the card has pulled away from the backplane Reseat the card in its slot You do not have to turn off the system power to do this After the system reinitializes the interfaces the enabled LED on the card should come on 3 Ifthe enabled LED remains off after the above checks it is likely that the system has detected a processor hardware failure Contact Cisco TAC for further information and help To access the Cisco TAC website use the URL http www cisco com tac Figure 5 LEDs eer or CC T Enabled 95803 e Upstream Downstream LEDs LEDs US0 US5 DS Table 1 LEDs Status LED Status Description Table 2 Technical Specifications continued Description Order Num Specifications Blank covers UBR MC COVER Weight MC16U E 16U Weight MC16X 5 25 lbs 2 38 kg 4 75 lbs 2 16 kg Power MC16U E 16U 62 Watts 211 6 BTU h MC16X 47 Watts 160 4 BTU h RF output power range 50 to 61 dBmV Output MC16U 50 to 61 dBmV at RF E 16U Output MC16X 42 dBmV at IF 2 dB Modulation Upstream USO USS5 QPSK 8 16 32 64 QAM Downstream DS 64 QAM 256 QAM Frequency range Upstream 5 65 MHz Downstream 70 860 MHz ENABLED Green Card op
5. erating normally ENABLED Off Card not enabled The Cisco MC16 line card is compatible with most cable systems worldwide including but not limited to Asia Pacific Europe and the Americas See Cisco IOS release notes for more information Caution A partially seated line card can cause the router to reboot 2 Are all enabled LEDs on If yes the system is operational If no check the following possibilities a Verify that the card has been enabled and configured for operation The enabled LED remains off when a card has not been configured and enabled US Green Upstream enabled US Off Upstream not enabled DS Green Downstream enabled DS Off Downstream not enabled 7 Technical Specifications Table 2 Technical Specifications Description Order Num Specifications Cisco uBR MC16U UBR MC16U with upconverter UBR MC16U Cisco uBR E 16U UBR E16U UBR E16U with upconverter Cisco uBR MC16X without upconverter UBR MC16xX UBR MC16X S Related Documentation For more information refer to the following at Cisco com e Cisco uBR7200Series Universal Broadband Hardware Installation Guide e Cisco uBR7200 Series Cable Interface Line Card Installation Guide e Cisco uBR7200 Series Universal Broadband Software Configuration Guide e Cisco CMTS Error Messages e Cisco CMTS Feature Guide For information about the 1 year warranty see the following URL http www cisco com en US p
6. m ports USO USS Cabling the Cisco uBR MC16X The Cisco uBR MC16X cable interface line card not supported on Cisco uBR7225VXR does not have an onboard upconverter The card may require up to 10 dB of attenuation due to a higher IF output power higher than legacy Cisco cable interface line cards To cable the card Step1 Connect the downstream cable to the downstream DS port on the card The IF downstream port ring and end tabs are yellow See Figure 3 Step2 Add RF attenuators as required to get the correct IF output Insert the attenuator between the downstream IF output cable and the upconverter See Figure 3 Step3 Connect the upstream cables to the upstream ports on the card USO USS Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA otfrcn as CISCO http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Cisco Cisco Systems the Cisco logo and the Cisco Systems logo are registered trademarks or trademarks of Cisco Systems Inc and or its affiliates in the United States and certain other countries All other trademarks mentioned in this document or Website are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 0705R 2009 Cisco Systems Inc All rights reserved OL 18974 01 Figure 3 Inserting an Attenuator