Home

Channel Plus H612 User's Manual

image

Contents

1. Wiring Modular Plug T568A Wiring a Cat 5 jack Keep sheath close to connector Untwist 5 max 110 punch down tool The 110 is a sophisticated insulation displacement connection system To push the wire between the contact blades use only a a screwdriver or needle nose pliers may not seat the wire properly and can damage the contacts 110 punch down tool Using Note order of colors From telephone company exchange 2 lines H618 telephone expansion hub CAT 5 jumper included Install this jumper for normal operation Remove to disconnect telephone service from the system 2 lines to telephone wall plates Each line is individually surge protected to 50 Joules and 4000 Amps Some surges contain sufficient energy that although your system has been protected the surge circuit will be unable to provide additional protection When this happens the red light for that line will turn on and the module needs to be returned for service CAT 5 4 UTP RG 6 coax Telephone in house Telephone from telco Data Security Downstream External to TVs Upstream Internal from modulators Insert wires in this order White Green Green White Orange Blue White Blue Orange White Brown Brown ChannelPlus model H612 Telephone Entry Module surge disconnect 4 3 2 1 From NTE 1 2 Disconnect In Out Expansion Output Surge Warning Line 2 Line 1 5 6 3 2 1
2. 4 5 6 5 Line 2 2 3 5 Line 1 2 3 Telephone Output H612 ChannelPlus model H612 Telephone Entry Module surge disconnect 4 3 2 1 From NTE 1 2 Disconnect In Out Expansion Output Surge Warning Line 2 Line 1 5 6 3 2 1 4 5 6 5 Line 2 2 3 5 Line 1 2 3 Telephone Output Line 1 Line 2 2 3 5 2 3 5 Modular connectors Wiring a 110 connector Wire Color Codes Colors of OpenHouse wiring tm green black white red yellow blue TIP TIP TIP TIP RING RING RING RING Cat5 4 pair UTP blue white blue orange white orange green white green brown white brown pair 1 pair 2 pair 3 pair 4 pair 1 pair 2 pair 3 ChannelPlus Telephone Entry Module The provides a superior method of telephone connection to your system Each unit provides surge suppression for two lines and a master disconnect Also each line has an LED status indicator to warn you of a surge event H612 Telephone Entry Module Typical Installation IMPORTANT INSTRUCTIONS When using your telephone equipment basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 Read and understand all instructions 2 Do not use this product near water for example near a bath tub wash bowl kitchen sink or laundry tub in a w
3. 110D 4 J8 Blu 110D 4 J7 Blu RJ 45 J9 RJ 45 J10 110D 4 J1 110D 4 J2 110D 4 J3 110D 4 J4 110D 4 J5 110D 4 J6 Blu Blu Blu Blu Blu Blu Telephones Expansion Ports In Out ChannelPlus model H618 Telephone Expansion Hub 4 lines x 8 phones R T R T R T R T 4 3 2 1 Solid Color Twisted Pair Wire 6 position connectors 8 position connectors T T T T R R R T R T T R T R R T T R R R 1 1 1 1 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 7 5 6 6 6 8 6 PR2 PR1 PR3 PR2 PR1 PR2 PR1 PR3 PR4 PR1 RJ 11 Single line telephones answering machines amp modems RJ 14 Dual line telephones amp answering machines RJ 25 Rare 3 line KSU RJ 45 wired to TIA T568A standard Ethernet both 10BaseT and 100BaseT Structured wiring of phones and data lines There are other wiring standards For residential use w RJ 45 jacks be wired to the T568A standard e recommend that Follow color code for T568A jacks Position first pair to channel closest to end of jack Do not untwist conductor pairs more than 0 5 from the termination point Keep sheath close to jack 1 Using a 110 punch down tool push wires into channels Repeat for subsequent pairs and trim 110 punch down tool 110 punch down tool 2 When all conductor pairs are terminated snap on strain relief caps 3
4. es RG 6 coax handles television antenna or cable satellite dish cable modem or AV modulator signals An AV modulator creates new TV channels for front door camera DVD player a VCR or a satellite receiver We recommend the following pre wire schemes Run these wires from the service center to the rooms indicated U T P Multiplex Technology Inc Brea CA 92821 Multiplex Technology Inc Brea CA 92821 600 210 Rev A 600 210 Rev A multiplex technology inc 3001 Enterprise Street Brea CA 92821 6213 U S A 714 996 4100 800 999 5225 FAX 714 996 4900 www openhousesystems com TM ChannelPlus Telephone Entry Module Model H612 Warranty Multiplex Technology Inc warrants this product to be free from defects in materials and workmanship for a period of one year from the date of purchase or MTI will repair or at its option replace the defective product To obtain warranty service call MTI for a return material authorization RMA number and return the product prepaid to Multiplex Technology Inc 3001 Enterprise Street Brea CA 92821 Attention Customer Service Please put the RMA number on the outside of the carton Any implied warranty arising from the sale of the product including implied warranties of merchantability and fitness for purpose are limited to the warranty stated above MTI shall not be responsible for losses or damages or expenses whether direct consequential or incidental ar
5. et basement or near a swimming pool 3 Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltages 4 SAVE THESE INSTRUCTIONS 1 2 3 1 Hook from the top 2 Swing into place 3 Push button to lock OpenHouse modules attach from the top tm ChannelPlus model H616 Telephone Master Hub 4 lines x 6 phones Telephone Master Hub 4 lines x 6 phones Telephones Telephones From Telco From Telco RJ31X Out Expansion Ports Expansion Ports R T R T 4 R T R T 3 R T R T 2 R T R T 1 SAFETY INFORMATION a Never install telephone wiring during a lighting storm b Never install telephone jacks in wet locations c Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface d Use caution when installing or modifying telephone lines Use self adhesive sticker provided to label the output I D Use CAT 3 or CAT 5 wires 2 lines to 8 telephone wall 3 4 5 6 1 2 3 4 5 6 1 2 ChannelPlus Enclosures Modules Accessories amp Wall Plates ChannelPlus model H628 Data Hub 8 cables TIA 568A Category 5 Compliant OUT IN 532 230 5MHz to 1000MHz OUT IN OUT IN OUT IN OUT IN SPLITTER COMBINER R Telephones From Telco ChannelPlus model H801 Combo Hub 2 lines x 6 phones 1input x 4 televisions R T 2 R T 1 Cha
6. ising from the use of or the inability to use this product Some states do not allow limitations on how long the implied warranty lasts or the exclusion or limitation or incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may have other rights which may vary from state to state
7. nnelPlus model H616 Telephone Master Hub 4 lines x 6 phones Telephones From Telco RJ31X Out Expansion Ports R T 4 R T 3 R T 2 R T 1 Starter systems RF splitters and telephone punch downs When it is time to upgrade just snap this module out and replace with one of more of the more sophisticated units Data hubs Termination blocks for the CAT 5 cables Ethernet hubs Bring the Internet to any room in the home Or create a home data network Telephone hubs Connections for 1 4 phone lines to every room Starter hub adds RJ 31X jack for security system dialer Coax panels Distribute antenna or cable TV to every room of the house Some models include bi directional amplifiers for interactive cable systems Some models include IR engines modulator inputs and AV modulators for service center Create a new TV channel for a front door camera Some models feature Cat 5 input connections TM Compatible Service center enclosures A full line of OpenHouse compatible enclosures from simple inexpensive mounting plates to high capacity in wall cabinets AC outlets can be mounted inside the cabinets using a UL listed accessory AV modulators for media center Create new TV channels for DVD VCR or a satellite receiver These modulators sit in the media center Some offer true MTS stereo model 5445 quad digital modulator pll frequency control D C B A program selec
8. t Wall plates Wall plate systems for all rooms The typical room gets TV and telephone The Home office wall plate adds data ports The media center wall plate adds satellite feeds IR Accessories Control video devices from any room New OpenHouse products are added all the time Visit our website to learn more www openhousesystems com Wiring a house for OpenHouse Typical Room Media Center Home Office Good Better Best 1 Cat 5 1 RG 6 1 Cat 5 3 RG 6 1 Cat 5 2 RG 6 2 Cat 5 1 RG 6 2 Cat 5 2 RG 6 2 Cat 5 3 RG 6 3 Cat 5 3 RG 6 2 Cat 5 2 RG 6 3 Cat 5 3 RG 6 Good Typical room phone TV Media center phone satellite receiver AV modulators Home office phone TV Better Typical room phone TV ethernet Media center phone TV satellite receiver AV modulators Home office Best cable modem ethernet phone TV ethernet cable modem Typical room phone TV ethernet satellite receiver Media center phone TV ethernet satellite receiver AV modulators hi speed data Home office phone TV ethernet satellite receiver cable modem hi speed data The cables in an OpenHouse run from the various rooms of the house directly to the service center location This is known as home run wiring Two types of wire are used for communication and entertainment Cat 5 4 UTP 4 nshielded wisted airs wire handles data or 1 to 4 telephone lin

Download Pdf Manuals

image

Related Search

Related Contents

FICHE SIGNALÉTIQUE 1. Identification du produit et de l`entreprise  Holmes HASF1650 User's Manual  LECTEUR DVD SD-9000E  DFT 2370-German - Besøg masterpiece.dk  有価証券報告書 - Honyaku Center Inc.  型 名 EP-PE20ES  LISST-ABS User`s Manual - Sequoia Scientific, Inc.  RN-TS2E-W6GSL・R/TRS2E-H6WWL・R/TRS2E  Symantec Manhunt Smart Agent for Dragon 6.0  TRFPi 0E PPM 020312A Operating Instructions  

Copyright © All rights reserved.
Failed to retrieve file