Home
Casio 2271 User's Manual
Contents
1. Module No 2271 2271 1 GETTING ACQUAINTED Congratulations upon your selection of this CASIO watch To get the most out of your purchase be sure to carefully read this manual and keep it on hand for later reference when necessary Applications The built in sensors of this watch measure direction altitude barometric pressure and temperature Measured values are then shown on the display Such features make this watch useful when hiking mountain climbing or when engaging in other such outdoor activities Warning e The measurement functions built into this watch are not intended for taking measurements that require professional or industrial precision Values produced by this watch should be considered as reasonable representations only e When engaging in mountain climbing or other activities in which losing your way can create a dangerous or life threatening situation always be sure to use a second compass to confirm direction readings e CASIO COMPUTER CO LTD assumes no responsibility for any loss or any claims by third parties that may arise through the use of this watch GENERAL GUIDE e If the digital display of your watch is continuously changing see Auto Display Function for information on how to stop it e The illustration below shows which buttons you need to press to navigate between modes Recall Mode Press Timekeeping Mode Alarm Mode el ee hehe
2. Altimeter Mode hold down for about one second to toggle the auto light switch on auto 48 displayed or off auto not displayed e Pressing while in the Timekeeping Digital Compass or Altimeter Mode initially switches to the Barometer Thermometer Mode Keeping depressed toggles the auto light switch on or off e The auto light switch on indicator auto 4 is on the display in all modes while the auto light switch is turned on e In order to protect against running down the batteries the auto light switch automatically turns off approximately six hours after you turn it on Repeat the above procedure to turn the auto light switch back on if you want QUESTIONS amp ANSWERS Question What causes incorrect direction readings Answer e Incorrect bidirectional calibration Perform bidirectional calibration Remember that bidirectional calibration is required whenever batteries are replaced e Nearby source of strong magnetism such as a household appliance a large steel bridge a steel beam overhead wires etc or an attempt to perform direction measurement on a train boat etc Move away from large metal objects and try again Note that digital compass operation cannot be performed inside a train boat etc Question What causes different direction readings to produce different results at the same location Answer Magnetism generated by nearby high tension wires are interfering with detection of terrestrial magnetis
3. South West southwest southwest West North northwest Northwest northwest Northeast Southeast Southwest e You can adjust the rotary direction bezel so that the N is aligned with the magnetic north pointer This correctly aligns all of the markings on the bezel e The Digital Compass operation is automatically interrupted whenever an alarm Daily Alarm or Hourly Time Signal sounds If this happens start the Digital Compass operation again from the beginning e See Digital Compass Precautions for other important information about taking direction readings Direction bezel BAROMETER THERMOMETER This watch uses a pressure sensor to measure air pressure barometric pressure and a temperature sensor to measure a temperature e You can calibrate the temperature sensor and the pressure sensor if you suspect that readings are incorrect 2271 2 Understanding the Barometer Thermometer Screen Barometric pressure graph Press to enter the Barometer Thermometer unit 1hPa mb 0 05 inHg Mode ees one e Barometric pressure is displayed in units of 1hPa mb or 0 05inHg e Temperature is displayed in units of 0 1 C or 0 2 F e The displayed barometric pressure value changes to hPa mb or inHg if a measured barometric pressure falls outside the range of 260 hPa mb to 1100 hPa mb 7 65 inHg to 32 45 inHg The barometric pressure value will be displayed again a
4. and temperature decrease as altitude increases This watch bases its altitude measurements on International Standard Atmosphere ISA values stipulated by the International Civil Aviation Organization ICAO These values define relationships between altitude air pressure and temperature Altitude Air Pressure Temperature 4000 m 616 hPa mb About 8 hPa mb per 100m _ 11 C 3500 m ae 3000 m 701 hPa mb About 9 hPa mb per 100m 4 5 C 2500 m eu eRe 2000 m 795 hPa mb About 10 hPa mb per 100 m __2 C Per 1900 m 1500 m 1000 m 899 hPa mb About 11 hPa mb per 100m 8 5 G 500 m Om 1013 hPa mb About 12 hPa mb per 100 m 15 C Source International Civil Aviation Organization 14000 ft 12000 ft 19 08 inHig About 0 15 inHg per 200 ft _16 2 F 10000 ft i 8000 ft 22 23 inHg About 0 17 inHg per 200 ft _30 5 F About BSF 6000 ft ie i 4000 ft 25 84 inHg J About 0 192 inHg per 200 ft 44 7 gt P 2000 ft 29 92 inHg About 0 21 inHg per 200 ft 59 0 F Source International Civil Aviation Organization There are two standard methods of expressing altitude Absolute altitude and relative altitude Absolute altitude expresses an absolute height above sea level Relative altitude expresses the difference between the height of two different places ooo rah Rooftop at an altitude of ooo Height of building 130 m Soe Relative altitude 230 m above sea level Altitude above sea leve
5. 4 15 58 35 Stopwatch Mode TIMEKEEPING indi Use the Timekeeping Mode to set and view TM indicator Seconds the current time and date Day of week To reset the seconds count to zero 1 In the Timekeeping Mode hold down until the second digits start to flash which indicates the setting screen 2 Press to reset the seconds count to 0 e Pressing while the seconds count is in the range of 30 to 59 resets the seconds to HJ and adds 1 to the minutes In the range of 00 to 29 the minutes count is unchanged 3 Press to exit the setting screen Hour Minutes Month Day About This Manual e Button operations are indicated using the letters shown in the illustration e Each section of this manual provides you with the information you need to perform operations in each mode Further details and technical information can be found in the REFERENCE section In any mode hold down for about one second to return to the Timekeeping Mode You can use buttons and to directly enter a sensor mode from the Timekeeping Mode or from another sensor mode To get to a sensor mode from the Recall Alarm or Stopwatch Mode you must go to the Timekeeping Mode first Sensor Modes Digital Compass Mode Press Barometer Thermometer Mode To set the time and date 1 In the Timekeeping Mode hold down Of m 6 hg O
6. G 638 until the second digits start to flash which indicates the setting screen Seconds Hour gt Minutes 2 Press to move the flashing in the sequence shown below to select other settings 12 24 Hour Format Day le Month Year 3 While a setting is flashing use and to change it e When the 12 24 hour setting is selected press or to toggle between 12 hour H and 24 hour 24 timekeeping 4 Press to exit the setting screen DIGITAL COMPASS A built in bearing sensor detects magnetic north and indicates one of 16 directions on the display Direction readings are performed in the Digital Compass Mode e You can calibrate the bearing sensor if you suspect the direction reading is incorrect To enter and exit the Digital Compass Mode 1 While in the Timekeeping Barometer Thermometer or Altimeter Mode press to enter the Digital Compass Mode e At this time the watch immediately starts a Digital Compass operation After about two seconds letters appear on the display to indicate the direction that the 12 o clock position of the watch is pointing 2 Press to return to the Timekeeping Mode To take a direction reading 1 Enter the Digital Compass Mode 2 Place the watch on a flat surface or if you are wearing the watch make sure that your wrist is horizontal in relation to the
7. You can set the altitude alarm value within the range of 10 000 to 10 000 meters 32 800 to 32 800 feet e Pressing and at the same resets the altitude alarm value to 4 Press to exit the setting screen To turn the altitude alarm on and off 1 In the Altimeter Mode hold down until the display clears After four or five seconds either HFF or the current reference altitude value if set will start to flash which indicates the setting screen 2 Press once to move the flashing to the altitude alarm setting 3 Press to switch the altitude alarm on GM and off GFF 4 Press to exit the setting screen e If the altitude alarm is on the altitude alarm on indicator remains on the display when you change to another mode Altitude alarm on indicator Current On Off status Memory Data Management Each altitude record includes an altitude reading plus the month day hour and minutes the measurement was taken Records are displayed in the order they were saved Memory can hold up 50 records You can store 50 Auto measurement records 50 Manual measurement records or any mixed combination of Auto and Manual measurement records In addition there are two extra records that show the highest max and lowest min altitude values from among the displayed data Altimeter Mode measurements and memory data Memory measurements The following example illustrates how data would be arranged in memory af
8. ains lit for about one second from the point you press the button even if it is already lit when you press the button If you keep the button depressed for one second or more the backlight automatically turns off e Frequent use of the backlight shortens the battery life 2271 7 Auto light switch precautions e Avoid wearing the watch on the inside of your wrist Doing so causes the auto light switch to operate when it is not needed which shortens battery life If you want to wear the watch on the inside of your wrist turn off the auto light switch feature More than 15 degrees e The backlight may not light if the face of the too high watch is more than 15 degrees above or below parallel Make sure that the back of your hand is parallel to the ground x e The backlight turns off in about one second N even if you keep the watch pointed towards your face e Static electricity or magnetic force can interfere with proper operation of the auto light switch If the backlight does not light try moving the watch back to the starting position parallel with the ground and then tilt it back toward you again If this does not work drop your arm all the way down so it hangs at your side and then bring it back up again e Under certain conditions the backlight may not light until about one second after you turn the face of the watch towards you This does not necessarily indicate malfunction of the backlight Digital Compass Precautio
9. d by the watch with those of another reliable and accurate thermometer e If adjustment is required remove the watch from your wrist and wait for 20 or 30 minutes to give the temperature of the watch time to stabilize 2271 8 To calibrate the temperature 1 Press to enter the Barometer Thermometer Mode 2 Hold down until the message MF F appears flashing which indicates the setting screen e A temperature value appears instead of GFF factory calibration if you previously calibrated the temperature sensor 3 Each press of increases the displayed temperature by 0 1 C or 0 2 F while pressing decreases it e Pressing and at the same time returns to the factory calibration GFF e The indicator TEMP ADJ on the display indicates that the temperature value has been calibrated 4 Press to return to the Barometer Thermometer Mode screen Calibrating the Barometric Pressure Sensor The pressure sensor of this watch is calibrated at the factory before shipment and further adjustment is normally not required If you notice serious errors in the barometric pressure readings produced by the watch you can calibrate the sensor to correct the errors Important Incorrectly calibrating the barometric pressure sensor can result in incorrect readings Before performing the calibration procedure compare the readings produced by the watch with those of another reliable and accurate barometer To calibra
10. easurement cuts off automatically whenever there are 49 records stored in memory The 50th record measurement when you stop measurement in step 3 above is also stored in memory e A final measurement is taken when you turn off Auto measurement and that data is also stored into memory Such data is indicated by F TiM during the recall operation To use Manual measurement 1 Confirm that the MANUAL indicator is shown on the display e If itis not use the procedure under To select Auto or Manual measurement to select Manual measurement 2 Inthe Altimeter Mode hold down until the watch emits a short beep indicating that a measurement is taken e Repeat step 2 whenever you want to take a reading e Button operation becomes impossible during the four or five seconds that it takes to complete a measurement Normal operation will return once the operation is finished Setting a Reference Altitude After you set a reference altitude the watch adjusts its air pressure to altitude conversion calculation accordingly The altitude measurements produced by this watch are subject to error caused by changes in air pressure Because of this we recommend that you update the reference altitude whenever one is available during your climb To set a reference altitude 1 In the Altimeter Mode hold down until the display clears After four or five seconds either HFF or the current reference altitude value if set will start to flash w
11. er Mode hold down until the display clears After four or five seconds either HFF or the current reference altitude value if set will start to flash which indicates the setting screen 2 Press twice to move the flashing to the memory measurement setting AUTO or MANUAL e Press to move the flashing in the sequence shown below Reference Altitude Memory Altitude Altitude Alarm gt Measurement gt Unit 3 While the memory measurement setting is flashing press or to select AUTO Auto measurement or MANUAL Manual measurement 4 Press to exit the setting screen e An indicator on the display shows the type of measurement AUTO or MANUAL that you currently have selected To use Auto measurement 1 Confirm that the AUTO indicator is shown on the display e If itis not use the procedure under To select Auto or Manual measurement to select Auto measurement 2 Inthe Altimeter Mode hold down until the watch emits a short beep indicating the start of the measurement 3 To stop measurements at any point in the Altimeter Mode hold down again until the watch emits a short beep e The data that is measured when you first start Auto measurement is also stored into memory e The AUTO indicator flashes on the display when you start Auto measurements The AUTO indicator continues to flash indicating that measurements continue even if you change modes e Auto m
12. es magnetized Because of this you should be sure to store the watch away from magnets or any other sources of strong magnetism including permanent magnets magnetic necklaces etc and household appliances TVs personal computers washing machines freezers etc e Whenever you suspect that the watch may have become magnetized perform one of the calibration procedures under Calibrating the Bearing Sensor below Calibrating the Bearing Sensor Whenever you suspect that direction readings produced by the watch are wrong you should calibrate it You can use either one of two calibration procedures bidirectional calibration or northerly calibration Use bidirectional calibration when you want to take readings within an area exposed to magnetic force This type of calibration should be used if the watch become magnetized for any reason With northerly calibration you teach the watch which way is north which you have to determine with another compass or some other means You could use this calibration procedure for example to set the watch to indicate true north instead of magnetic north Important e If you want to perform both bidirectional and northerly calibration be sure to perform bidirectional calibration first and then perform northerly calibration This is necessary because bidirectional calibration cancels any previously set northerly calibration setting e The more correctly you perform bidirectional calibrat
13. essing Alarm Time Hour Minutes Alarm on indicator Timekeeping Mode time Alarm number To set an alarm time 1 In the Alarm Mode use and to select the alarm whose time you want to set Press gt Press AL 1 AL 2 AL 3 SIG AL 5 4 AL 4 2 Hold down until the hour digits of the alarm time start to flash which indicates the setting screen e This automatically turns on the alarm 3 Press to move the flashing between the hour and minutes 4 While a setting is flashing use and to change it e When setting the alarm time using the 12 hour format take care to set the time correctly as a m no indicator or p m P indicator 5 Press to exit the setting screen Alarm Operation The alarm sounds at the preset time for about 20 seconds in all modes or until you stop it by pressing any button To test the alarm In the Alarm Mode hold down to sound the alarm To turn an alarm and the Hourly Time Signal on and off 1 In the Alarm Mode use and to select an alarm or the Hourly Time Signal 2 When the alarm or the Hourly Time Signal you want to is selected press to turn it on and off m Indicates alarm is ON 4 Indicates Hourly Time Signal is ON e The alarm on indicator m and the Hourly Time Signal on indicator 4 are shown on the display in all modes while these functions are turned on e If any alar
14. gital Compass Mode screen appears in the upper display area Changing the Barometric Pressure and Temperature Units Changing the barometric pressure units automatically restarts the barometric pressure graph To change the Barometric Pressure and Temperature Units 1 Press to enter the Barometer Thermometer Mode Hold down until the message fF F appears flashing which indicates the setting screen e A temperature value appears instead of GFF factory calibration if you previously calibrated the temperature sensor 3 Press to move the flashing in the sequence shown below Barometric Temperature gt oC Jo gt i Paai Pressure C F hPa mb inHg Calibration Calibration 4 Press to move the flashing to the unit setting you want to change C F or hPa mb inHg 5 Press or to select the unit you want 6 Press to return to the Barometer Thermometer Mode screen Calibrating the Temperature Sensor The temperature sensor of this watch is calibrated at the factory before shipment and further adjustment is normally not required If you notice serious errors in the temperature readings produced by the watch you can calibrate the sensor to correct the errors Important Incorrectly calibrating the temperature sensor can result in incorrect readings Carefully read the following before doing anything e Compare the readings produce
15. hich indicates the setting screen e DEE indicates no reference altitude 2 Press to increase the current reference altitude value by 5 meters or 20 feet or to decrease it e You can set the reference altitude within the range of 10 000 to 10 000 meters 32 800 to 32 800 feet e Pressing and at the same returns to SF F so the watch performs air pressure to altitude conversions based on preset data only 3 Press to exit the setting screen About the Altitude Alarm The altitude alarm sounds for about five seconds whenever the current altitude matches a preset value You can press any button to stop the alarm after it starts to sound Example If you set the altitude alarm at 130 meters it sounds when you pass the 130 meter mark on your way up and on your way back down To set the altitude alarm 1 In the Altimeter Mode hold down until the display clears After four or five seconds either GFF or the current reference altitude value if set will start to flash which indicates the setting screen 2 Press once to move the flashing to the altitude alarm setting e Press to move the flashing in the sequence shown below Reference Altitude Memory Altitude Altitude Alarm gt Measurement gt Unit 3 While the altitude alarm setting is flashing press to increase the current altitude alarm value by 5 meters or 20 feet or to decrease it e
16. horizon 3 Point the 12 o clock position of the watch in the direction you want to measure 4 Press to start a Digital Compass measurement operation e After about two seconds the direction that the 12 o clock position of the watch is pointing appears on the display e Also four pointers appear to indicate magnetic north south east and west e After the first reading is obtained the watch continues to take direction o3 readings automatically each second for A up to 30 seconds a e The COMP indicator flashes on the Z display while a measurement is in Q 5 Magnetic north pointer 12 o clock position Direction ONGESE 3 Timekeeping Mode time Direction value in degrees r gn NW Wwy progress e The direction value that appears on the gt display represents the clockwise angle IS 45 39 formed between magnetic north which is 0 degrees and the displayed direction 3 z n Z Gi Note e Note that taking a measurement while the watch is not horizontal in relation to the horizon can result in large measurement error e Pressing while in the Digital Compass Mode starts a new direction measurement operation e The following table shows the meanings of each of the direction abbreviations that appear on the display Meaning Direction Meaning Direction Meaning Direction Meaning North East northeast northeast East South southeast southeast
17. ion the better the accuracy of the bearing sensor readouts You should perform bidirectional calibration whenever you change environments where you use the bearing sensor and whenever you feel that the bearing sensor is producing incorrect readings To perform bidirectional calibration A 1 Enter the Digital Compass Mode g 2 Hold down until the upper display area an NN changes to show i which indicates the setting screen e Atthis time the magnetic north pointer flashes at the 12 o clock position to indicate that the watch is ready to calibrate the first direction O 3 Place the watch on a level surface facing any direction you want and press to calibrate the first direction e When the calibration procedure is complete the message in the upper display area This soon changes to magnetic north pointer flashes at the 6 o clock position to indicate that the watch is ready for the second direction Rotate the watch 180 degrees Press again to calibrate the second direction e When the calibration procedure is complete the message appears in the upper display area After a short while the watch automatically returns to the Digital Compass Mode screen ask Precautions about bidirectional calibration e You can use any two opposing directions for bidirectional calibration You must however make sure that they are 180 degrees opposite each other Remember that if you perform
18. l Sea Precautions Concerning Simultaneous Measurement of Altitude and Temperature Though you can perform altitude and temperature measurements at the same time you should remember that each of these measurements require different conditions for best results With temperature measurement it is best to remove the watch from your wrist in order to eliminate the effects of body heat In the case of altitude measurement on the other hand it is better to leave the watch on your wrist because doing so keeps the watch at a constant temperature which contributes to more accurate altitude measurements The following describes what you should do to give priority to either altitude or temperature e To give altitude measurement priority leave the watch on your wrist or in any other location where the temperature of the watch is kept constant e To give temperature measurement priority remove the watch from your wrist and allow it to hand freely from your bag or in another location where it is not exposed to direct sunlight Note that removing the watch from your wrist can momentarily affect pressure sensor readings Question How does the barometer work Answer Barometric pressure indicates changes in the atmosphere and by monitoring these changes you can predict the weather with reasonable accuracy Rising atmospheric pressure indicates good weather while falling pressure indicates deterioration weather condi
19. ltitude reading from among those e The contained in memory both Auto and Manual and the reading displayed in Altimeter Mode The tiri Highest Altitude Attained Lowest Altitude Attained e When you display the screen the message tifi alternates every second with the date in the upper display The message fi IT fi alternates L fd screen records are changed automatically whenever a measurement produces a reading that is greater than the current value or less than the current value Note e 50 records are enough to store 12 hours and 15 minutes of Auto measurement data if you do not take any Manual readings during that time Important e Further Auto or Manual measurements become impossible whenever memory is full The message Ff on the display indicates that memory is full Always check the amount of memory remaining before starting memory measurements and delete records if necessary Recalling Altitude Measurement Records Use the Recall Mode to recall altitude measurement records You can enter the Recall Mode by pressing the button e Measurement records are stored in memory even if an error occurs during the measurement For details on errors see Warning Indicators To recall altitude measurement records In the Recall Mode press to scroll forward through the stored records or to scroll backward e See Memory Data Management for information about how da
20. ly when the watch is in the Altimeter Mode As soon as you enter the Altimeter Mode measurements are taken every five seconds for the first three minutes After that measurements are taken every two minutes e The ALTI indicator flashes on the display while a measurement is in progress 2271 3 Memory measurements Memory measurements are taken independently of Altimeter Mode measurements and stored directly into memory along with the date and time of the measurement for later recall There are two types of memory measurements Auto measurements and Manual measurements Auto measurements With Auto measurement the watch continuously performs measurements whenever the minutes in the Timekeeping Mode reach 00 15 30 or 45 until you switch Auto measurements off The watch continues to take measurements regardless of whether or not you change modes so you can keep a running log of altitude changes automatically Manual measurements You can use the manual procedure to take a reading anytime you want to store your current altitude data into memory for later recall Manual memory measurements can be performed only while the watch is in the Altimeter Mode Selecting Auto or Manual Measurement Use the following procedure to switch between Auto or Manual measurement Note that you cannot perform this operation while a preset Auto measurement is already in progress To select Auto or Manual measurement 1 Inthe Altimet
21. m Move away from the high tension wires and try again Question What does it mean when appears in place of a direction Answer This is the abnormal magnetic field indicator It means that strong magnetism is being generated nearby Move away from the source of strong magnetism and try again Question Why am I having problems taking direction readings indoors Answer ATV personal computer speakers or some other object is interfering with terrestrial magnetism readings Move away from the object causing the interference or take the direction reading outdoors Indoor taking direction readings are particularly difficult inside ferro concrete structures Remember that you will not be able to take direction readings inside of trains airplanes etc Question What do the numbers on the watch mean Answer The face of this watch is marked with values that increase in a counterclockwise direction These values represent degrees When you take a direction reading you can use these values to find out how many degrees the 12 o clock position of this watch which is the direction indicated in the digital display differs from magnetic north For example when the Magnetic North Pointer is pointing at 90 on the watch s face it means that the 12 o clock position is 90 degrees from magnetic north which means that the 12 o clock pointing due east Question How does the altimeter work Answer Generally air pressure
22. m is on the alarm on indicator is shown on the display in all modes 2271 5 STOPWATCH The stopwatch lets you measure elapsed time es Seconds split times and two finishes e The display range of the stopwatch is 23 hours 59 minutes 59 99 seconds e The stopwatch continues to run restarting from zero after it reaches its limit until you stop it e The stopwatch measurement operation continues even if you exit the Stopwatch Mode All of the operations in this section are performed in the Stopwatch Mode which you enter by pressing Minutes 1 100 second To measure times with the stopwatch Elapsed Time Start Stop Re start Stop Clear Split Time o Start Split Split release Stop Clear Two Finishes Start Split Stop Split release Clear First runner Second runner finishes Record time of finishes Record time of first second runner runner BACKLIGHT The backlight uses an EL electro luminescent panel that causes the entire display to glow for easy reading in the dark The watch s auto light switch automatically Y turns on the backlight when you angle the watch towards your face The auto light switch must be turned on indicated by the auto light switch on indicator for it to operate e See Backlight Precautions for other important information about using the backlight Auto light switch on indicator To tu
23. malfunction and the condition should be corrected when you re calibrate the Digital Compass Important e If a sensor malfunctions or if battery power is low when it comes time for a measurement to be taken the measurement value appears as on the display In the case of barometric pressure measurement the corresponding point on the barometric pressure graph is left blank e There may be cases where the f Fz sensor malfunction low battery message disappears from the display when you change modes In this case you can continue using the watch normally unless the warning indicator reappears Whenever you have a sensor malfunction be sure to take the watch to an authorized CASIO distributor or service provider as soon as possible Auto Return Features e After you perform an operation in the Recall Alarm and Stopwatch Modes pressing returns to the Timekeeping Mode e If you leave the watch in the Digital Compass Barometer Thermometer or Altimeter Mode for 10 to 11 hours without performing any operation the watch beeps and automatically returns to the Timekeeping Mode e If you leave a screen with flashing digits on the display for two or three minutes without performing any operation the watch automatically saves anything you have input up to that point and exits the setting screen Data and Setting Scrolling The and buttons are used in various modes and setting screens to
24. n temperature changes can affect pressure sensor readings e Temperature measurements are affected by your body temperature while you are wearing the watch direct sunlight and moisture To achieve a more accurate temperature measurement remove the watch from your wrist place it in a well ventilated location out of direct sunlight and wipe off all moisture from the case It takes approximately 20 to 30 minutes for the case of the watch to reach the actual surrounding temperature e You can change the measured barometric pressure unit between hecto pascals millibars nPa mb and inchesHg inHg See Changing the Barometric Pressure and Temperature Units for details e You can change the measured temperature value displayed by this watch between Celsius C and Fahrenheit F See Changing the Barometric Pressure and Temperature Units ALTIMETER A built in altimeter uses a pressure sensor to detect the current air pressure which is then used to estimate the current altitude The watch is pre programmed with ISA International Standard Atmosphere preset values which are used to convert air pressure readings to altitude values If you preset a reference altitude the watch will also calculate the current relative altitude based on your preset value Altimeter functions also include data storage memory and an altitude alarm Important e This watch estimates altitude based on air pressure This means that altitude reading
25. ns This watch features a built in magnetic bearing sensor that detects terrestrial magnetism This means that north indicated by this watch is magnetic north which is somewhat different from true polar north The magnetic north pole is located in northern Canada while the magnetic south pole is in southern Australia Note that the difference between magnetic north and true north as measured with all magnetic compasses tends to be greater as one gets closer to either of the magnetic poles You should also remember that some maps indicate true north instead of magnetic north and so you should make allowances when using such maps with this watch Location e Taking a direction reading when you are near a source of strong magnetism can cause large errors in readings Because of this you should avoid taking direction readings while in the vicinity of the following types of objects permanent magnets magnetic necklaces etc concentrations of metal metal doors lockers etc high tension wires aerial wires household appliances TVs personal computers washing machines freezers etc e Accurate direction readings are impossible while in a train boat air plane etc e Accurate readings are also impossible indoors especially inside ferro concrete structures This is because the metal framework of such structures picks up magnetism from appliances etc Storage e The precision of the bearing sensor may deteriorate if the watch becom
26. o replace any directional temperature barometer or altitude values on the display Abnormal Magnetic Field Indicator This indicator appears whenever the watch has a problem obtaining a correct direction a reading This condition could indicate that the watch is within a very high magnetic field and so you should try moving to another location Also see Digital Compass Precautions for further information on conditions that cause errors Low Battery Indicator This message indicates that battery power is too low to perform the measurement It appears whenever battery power drops below a certain level or when you try to perform a measurement under very cold conditions below about 10 C 14 F If the cause of the low battery indicator is due to use under cold conditions normal operation should return after the watch is brought back to normal temperature If the cause of the low battery indicator is due to low battery power indicated when appears under normal temperatures you should have the watch s batteries replaced as soon as possible Note that replacement of the batteries causes all memory contents to be deleted Sensor Malfunction Indicator This message flashes on the display to indicate malfunction of pressure sensor circuitry Note that calibrating the Digital Compass can also cause the message to appear In this case the message does not indicate sensor
27. ore accurate than they would without a reference altitude e Note that the following conditions will prevent you from obtaining accurate readings When air pressure changes because of changes in the weather Extreme temperature changes When the watch itself is subjected to strong impact Understanding the Altimeter Screen Press to enter the Altimeter Mode Altitude graph current altitude flashing unit 10 40 ft a 1 second later Remaining memory 158 35 2 Timekeeping Mode time e Altitude is displayed in units of 5 meters 20 feet e The measurement range for altitude is 700 to 10 000 meters 2 300 to 32 800 feet e The measured altitude may be a negative value in cases where there is a reference altitude value set or because of certain atmospheric conditions e The displayed altitude value changes to meters or feet if a measured altitude falls outside the measurement range The altitude value will be displayed again as soon as the measured altitude is within the allowable range e You can change the unit of measurement for the displayed altitude values between meters m and feet ft See To change the Altitude Units About Altitude Measurements There are two types of altitude measurements those for displayed data Altimeter Mode measurements and those for memory data Memory measurements Altimeter Mode measurement This type of measurement is performed on
28. r bottom of the display The entire graph will become visible once barometric conditions stabilize Not visible on The following conditions cause the barometric pressure the display measurement to be skipped with the corresponding point on the barometric pressure graph being left blank e Barometric reading that is out of range 260 hPa mb to 1100 hPa mb or 7 65 inHg to 32 45 inHg e Sensor malfunction e Dead batteries About Barometric and Temperature Measurements e Barometric pressure and temperature measurement operations are performed as soon as you enter the Barometer Thermometer Mode After that temperature measurements are taken every five seconds for the first three minutes and then taken every five minutes thereafter e The BARO indicator flashes on the display while a measurement is in progress e The barometer automatically takes measurements every two hours starting from midnight regardless of what mode you are in The results of these measurements are used for the barometric pressure graph e You can also perform a barometric pressure and temperature measurement at any time by pressing in the Barometer Thermometer Mode Barometer and Thermometer Precautions e The pressure sensor built into this watch measures changes in air pressure which you can then apply to your own weather predictions It is not intended for use as a precision instrument in official weather prediction or reporting applications e Sudde
29. rn on the backlight manually In any mode press to illuminate the display for about one second e The above operation turns on the backlight regardless of the current auto light switch setting About the Auto Light Switch Turning on the auto light switch causes the backlight to turn on for about one second whenever you position your wrist as described below in any mode e Be sure to wear the watch on the outside of your left wrist while using the auto light switch Moving the watch to a position that is parallel to the ground and then tilting it towards you more than 40 degrees causes the backlight to turn on More than pe Mor ground Warning e Always make sure you are in a safe place whenever you are reading the display of the watch using the auto light switch Be especially careful when running or engaged in any other activity that can result in accident or injury Also take care that sudden illumination by the auto light switch does not surprise or distract others around you e When you are wearing the watch make sure that its auto light switch is turned off before riding on a bicycle or operating a motorcycle or any other motor vehicle Sudden and unintended operation of the auto light switch can create a distraction which can result in a traffic accident and serious personal injury 2271 6 To turn the auto light switch on and off In the Timekeeping Digital Compass Barometer Thermometer or
30. s ARG Temperature Barometric pressure soon as the measured barometric pressure is within the allowable range e The displayed temperature value changes to C or F if a measured temperature falls outside the range of 10 0 C to 60 0 C 14 0 F to 140 0 F The temperature value will be displayed again as soon as the measured temperature is within the allowable range e Some countries refer to the barometric pressure unit hecto pascal hPa as millibars mb It really makes no difference because 1hPa 1mb In this manual we use hPa mb or hPa mb Barometric Pressure Graph Barometric pressure indicates changes in the atmosphere By monitoring these changes you can predict the weather with reasonable accuracy The barometric pressure graph shows the barometric readings for the past 26 hours The flashing point on the right of the display is the point for the newest measurement Note that pressure graph readings are relative to the newest measurement point One dot above the newest point is plus 1hPa mb 0 05inHg while one dot below is minus 1hPa mb 0 05inHg The following shows how to interpret the data that appears on the barometric pressure graph x A rising graph generally means improving weather A falling graph generally means deteriorating weather Note that if there are sudden changes in weather or zy temperature the graph line of past measurements may run off the top o
31. s for the same location may vary if air pressure changes e This watch employs a semiconductor pressure sensor which is affected by temperature changes When taking altitude measurements be sure to do so while ensuring that the watch is not exposed to temperature changes e Do not rely upon this watch for altitude measurements or perform button operations while engaging in sports where there are sudden altitude changes while sky diving hang gliding or paragliding or while riding a gyrocopter glider or any other aircraft e Do not use this watch for measuring altitude in applications that demand professional or industrial level precision How the Altimeter Works With the Preset Values No Reference Altitude e The watch measures the air pressure at your current location and uses the built in ISA values to convert it to the equivalent altitude With a Reference Altitude e After you set the reference altitude the watch adjusts its air pressure to altitude conversion calculation accordingly e To determine the height of a tall building Re set the reference altitude to 0 on the ground floor Note however that you may gt not be able to get a good reading if the building is pressurized or air conditioned a e When mountain climbing you can set the reference value in accordance with a marker along the way or altitude information from a map After you do this the altitude readings produced by the watch will be m
32. scroll through data on the display In most cases holding down these buttons during a scroll operation scrolls through the data at high speed Timekeeping e The day of the week is automatically displayed in accordance with the date year month and day settings e The year can be set in the range of 2000 to 2039 e The watch s built in full automatic calendar automatically makes allowances for different month lengths and leap years Once you set the date there should be no reason to change it except after you have the watch s batteries replaced 12 hour 24 hour Timekeeping Formats The 12 hour 24 hour timekeeping format you select in the Timekeeping Mode is also applied in all modes e With the 12 hour format the P PM indicator appears to the left of the hour digits for times in the range of noon to 11 59 p m and no indicator appears to the left of the hour digits for times in the range of midnight to 11 59 a m e With the 24 hour format times are displayed in the range of 0 00 to 23 59 with 24 indicator Backlight Precautions e The electro luminescent panel that provides illumination loses power after very long use e The illumination provided by the backlight may be hard to see when viewed under direct sunlight e The watch will emit an audible sound whenever the display is illuminated It does not indicate malfunction of the watch e The backlight automatically turns off whenever an alarm sounds e The backlight rem
33. ta is stored Date Deleting an Altitude Measurement Record Use the Recall Mode to delete altitude measurement records You can enter the Recall Mode by pressing Note e The procedure you should use to delete a record depends on if the record was produced by Auto measurement or Manual measurement Deleting Auto measurement records deletes the entire set from the initial record to the final record e You cannot delete a record that is part of an ongoing Auto measurement operation indicated when AUTO is flashing on the display You can however delete records from another already completed measurement operation To delete a altitude measurement record 1 Inthe Recall Mode display the record you want to delete e If you want to delete a set of Auto measurement records display the first record of the set 2 To clear the data hold down until the watch emits a long beep and until LF stops flashing on the display First record of the set ALARM You can set five independent Daily Alarms When an alarm is turned on the alarm tone sounds when the alarm time is reached You can also turn on an Hourly Time Signal that causes the watch to beep twice every hour on the hour e The alarm number through indicates an alarm screen 3 appears in place of FL when the Hourly Time Signal screen is shown e All of the operations in this section are performed in the Alarm Mode which you enter by pr
34. te the barometric pressure 1 Press to enter the Barometer Thermometer Mode 2 Hold down until the message SF F appears flashing which indicates the setting screen e A temperature value appears instead of OFF factory calibration if you previously calibrated the temperature sensor 3 Press to move the flashing to the barometric pressure calibration setting e Atthis time GFF or the barometric pressure value should be flashing on the display 4 Each press of increases the displayed barometric pressure by 1 hPa mb 0 05 inHg while pressing decreases it e Pressing and at the same time returns to the factory calibration GFF 5 Press to return to the Barometer Thermometer Mode screen To change the Altitude Units 1 Press to enter the Altimeter Mode 2 Hold down until the display clears After four or five seconds either HEF or the current reference altitude value if set will start to flash which indicates the setting screen 3 Press three times to move the flashing to the altitude unit setting 4 Press or to select the unit you want m or ft 5 Press to return to the Altimeter Mode screen e Changing the altitude units automatically turns the altitude alarm off e Changing the altitude units automatically restarts the altitude graph e Performing the above procedure causes altitude values stored in memory also to be converted to the unit you select
35. ter you perform one Auto measurement Auto 1 two Manual measurements Manual 1 Manual 2 and then one Auto measurement Auto 2 iis gt Manual 1 gt Manual 2 Auto 2 gt MAX MIN M e Note that the highest i and lowest f 4 records always are last 2271 4 Auto Measurement Records e Performing an Auto measurement produces a set of records of all the measurements taken during the Auto measurement session Since Auto measurement produces four altitude readings per hour at 00 15 30 and 45 minutes of each hour leaving Auto measurement turned on for two hours would result in a set of eight records The following shows how the records that make up an Auto measurement set appear when you recall them AUTO indicator Altitude graph First record All records between the initial Final record of the set screen and final screen of the set The altitude graph separates the maximum and minimum altitude readings by nine display dots Other readings are shown relative to the maximum and minimum Note that Auto measurement records are always treated as a set This means that deleting one record in a set deletes the entire set Manual Measurement Records e Performing a Manual measurement produces a single record The illustration below shows how a Manual measurement record appears when you recall it MANUAL indicator and of i record shows the lowest a
36. the procedure incorrectly you will get wrong bearing sensor readings e Do not move the watch during the one or two seconds from the point you press up to the point that appears in the upper display area that the calibration of each direction is in progress If you do the message appears in the upper display area which means you have to restart the bidirectional calibration procedure from the beginning e The appearance of z during bidirectional calibration can also be caused by local inte rence If you suspect that this is the case move to another location and try the procedure again You should perform bidirectional calibration in an environment that is the same as that where you plan to be taking direction readings If you plan to take direction readings in an open field for example calibrate in an open field To ie weg calibration 1 While in the Digital Compass Mode hold down until the upper display area changes to show 1 which indicates the setting screen 2 Press to start the northerly calibration procedure e At this time the indicator direction f 4 3 Place the watch on a level surface and position it so that its 12 o clock position points north as measured with another compass 4 Press to start the calibration operation e When the calibration procedure is complete the message appears in the upper display area After a short while the watch automatically returns to the Di
37. tions The barometric pressures that you see in the newspaper and on the TV weather report are measurements corrected to values measured at 0 m sea level Question What should do if lose track of which mode am in or lose my way when making settings Answer Hold down for about one second to return to the Timekeeping Mode Next try performing the operation you want again REFERENCE This section contains more detailed and technical information about watch operation It also contains important precautions and notes about the various features and functions of this watch Auto Display Function Auto Display function of this watch continually changes the contents of the digital display NN Note that you cannot use any of the watch s ri other functions while the Auto Display function HELER is operating rm amp oo 6 35 z To turn the Auto Display off Hold down for about three seconds until the watch beeps To turn the Auto Display on In the Timekeeping Mode hold down for about three seconds until the watch beeps three times e Note that the Auto Display function cannot be performed while you are making settings Warning Indicators Warning indicators appear whenever any of the conditions described below occur Appearance of a warning indicator causes any measurement operation that is currently underway to stop Warning indicators appear in the upper display area and this causes t
Download Pdf Manuals
Related Search
Related Contents
Manuel d`installation et d`entretien Vérin ISO série, 55-CP96 GIMA HAloGen SkIn SurfAce MIcroScope 10X HeIne DelTA 20 the product installation manual Philips FM08SD45B Istruzioni per l`uso Logamax plus Télécharger la plaquette des conférences 2015-2016 MANUAL DE INSTRUCCIONES MULTI XS 7000 la formation - Chausson Matériaux Copyright © All rights reserved.
Failed to retrieve file