1. Note Fan may wobble or vibrate if pole length is not long enough and inside blade is too close to downslope or side wall Extending pole length will usually solve problem EXAMPLE 2 This slope is 32 This is the maximum slope that will allow the fan to hang straight down It is OK to install your fan Calculation of 32 Use the tear off Ceiling Angle Template card inserted in the back of this manual it provides you with a simple go or no go for installing your fan on a sloped ceiling EXAMPLE 3 EXAMPLE 1 i This slope is more than 32 This slope is less than 32 Your fan will not hang straight down an It is OK to install your fan adaptor is necessary Contact your local Authorized Casablanca Dealer in regards to purchasing a Slope Ceiling Adaptor SA Unpacking Before assembling and installing your ceiling fan remove all parts from the shipping cartons and check them against the parts listed here Before discarding packaging material be certain that all parts have been removed ALLEN SET SCREW Y4 20 x Ya PRE NSTALLED D 3mm IMPORTANT SAFETY INFORMATION BEFORE STARTI NG THE INSTALLATION OF YOUR CEILING FAN INSTALL THE THREADED DOWNROD INTO THE MOTOR COUPLING AND LOCK THE ASSEMBLY Prepare for fan installation as follows Step A Route the wires from the motor through the PermaeLock downrod and ball assembly Tip The downro
2. ny O00000 v l o0o000 OD to help with the installation 10 e When cleaning painting or working near your fan be very careful of the fan and blades CIRCUIT BREAKER Always turn the power OFF to the ceiling fan TRIP BREAKER FOR THE 84 before servicing it working on it or replacing CIRCUIT YOU WILL BE light bulbs WORKING ON e Never insert anything into the path of the een fan blades while the fan is in operation BS e Never install a fan over a pool or spa a tel e Never operate a fan that has been damaged in any way Contact Casablanca Fan Company S by calling toll free 1 888 227 2178 or aa ee contact your local authorized Casablanca dealer for assistance in obtaining service P N 9543020 REV B P D JUNO1IPDG i a TAN ere Before mounting your Casablanca fan read the following helpful recommendations The location of the fan air circulation and fan size are all important factors to consider before installation Location Ceiling fans have practical uses in almost every room in your home We suggest you follow these mount ing recommendations as you decide where to install your Casablanca fan e For safety reasons the fan blades must be a minimum of 7 above the floor e Do not locate the fan in a doorway or above a swinging door e In any installation the tips of the blades must be at least 18 from the wall in order to provide suffi
3. BRESCIA GALLERY EDITION Owner s MANUAL CONTENTS eG Cttrt eet tents cert Seer eee ee cr ee eee oe i ee ee hee ere eee ae eer a 1 MOUNTING RECOMMENDATIONS ccc cee ee 2 PREPARATION INSTRUCTIONS ijcled ita a iors tine aaa eA ee OA i eR be eras 3 FAN INSTALEATION arininn inoran anaia ar acai ark sane aun an race ica kane avnca aries on a a ina aA 4 CONTROL FEATURES INTEETe TOUCH OPERATION asi 6 5 i5 20 erick aon ee Wee daa es a ae A ea de Se a aa 11 INTELI TOUCH TROUBLESHOOTING cic iii sctseck ahaa eh wera a ee ee Oe a 14 COMFORT TOUCH OPERATION lt iisisSoiciwa ears a wa Aad a ae a ae ae Aaa a aaa ae 15 COMFORT TOUCH TROUBLESHOOTING is saaman a we ea ee ae apa sei in ce ay AC Bo Oe a 19 SAFETY FIRST Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product and proper installation therefore before attempting to install and operate your Casablanca fan read this owner s manual completely and carefully Retain this manual for future reference CAUTION To avoid possible electrical shock make certain that electricity is turned off at the circuit breaker or fuse box before attempting any installation procedure All wiring must be in accordance with the National Electric Code ANSI NFPA 70 1993 and the appropriate local electrical codes The National Electric Code requires proper grounding as a precaution against electrical shock A qualified electri cian
4. LAST tween the canopy and ceiling or Hang Tru f Note Write down the CANOPY ball and top support shaft Serial Number and the SCREW model number for future reference a ieee ANGA PREPARATI ON Step 8 To reach the blade holder mounting holes in the fan motor the dummy switch housing must be removed Take out the two 5 32 X 32 screws secur ing the dummy switch housing and remove Set the two 2 screws aside for the mo ment they will be used in Step 12 to install the switch housing after the blades are in stalled The dummy switch housing is used only when shipping the fan Note Save these two screws they will be used in Step 12 HOUSI NG BLADE amp BLADE HOLDER HARDWARE BLADE SCREW CCE 4 PER BLADE BLADE HOLDER SCREW J cee 2 PER BLADE BLADE HOLDER BLADE INSTALLATION Step 9 Attach the blades to the blade holders by first pressing the blade badge into the blade then installing the blade holder using the four blade screws and flat washers provided for each blade BLADE HOLDER Using the screwdriver tighten securely by hand only Repeat for each blade assembly ae BLADE SCREW 4 PER BLADE BLADE BRESCIA GALLERY EDITION REMOVE SHIPPING BLOCKS Step 10 On the flywheel remove the four SHIPPING shipping blocks by unscrewing the screws BLOCKS NA Discard the shipping blocks and shipping X g block screws BLADE BL
5. SWITCH HOUSING MOUNT SCREW 5 32 X 9 32 2 Step A4 Line up the two clearance holes in the cap with the two threaded holes on the raised rim of the switch housing Press the cap onto the switch housing to seat the guide pins into the alignment holes of the switch housing Step A5 Using the two 2 8 32 X 3 s screws removed in Step A1 install the cap onto the switch housing Tighten securely by hand only CAP SCREW 8 32 X 3 38 2 Inteli Touch INTELI TOUCH INSTALLING THE W 32 WALL CONTROL The wall control installs in the same manner as an ordinary light switch using an existing junction box and wiring This controller is designed to signal the fan microcomputer as well as perform normal switching operations For this reason the following precautions must be observed 1 Use only the Casablanca W 32 wall control 3 Do not use more than one fan per wall control 2 Do not use any additional control with your Inteli Touch 4 No other light fixtures or electrical appliances may be con fan for example dimmer fan speed control etc nected on the circuit controlled by the W 32 wall control INTELI TOUCH SINGLE W 32 INSTALLATION CAUTION Ensure power is turned OFF at the breaker NEUTRAL WHITE or fuse panel before starting installation os W 32 is used to describe either white 11 or ivory finish GREEN 1 Remove the screws and swit
6. increase or decrease by one speed for each 1 5 F increase or decrease in temperature If temperature decreases enough to turn the fan OFF the Auto Speed indicator will flash slowly to remind you that the fan will turn on when the temperature increases Note The temperature displayed is from an electronic thermometer built into the remote control that reads room temperature It is not AUTO SPEED REVERSE S af SAVER TEST _ WINTER Replace batteries ITO S TI Lo is displayed fan speed control a thermostat that controls the room temperature To cancel Auto Speed simply push the button again TEMPERATURE ACCURACY 3 F Selecting also cancels Auto Speed SAVER FEATURE The Saver mode will automatically turn lights off 1 hour after the AUTO SECURITY REVERSE lights are turned on Press the button and SAVER will appear in test WINTER the display An audio tone will warn you 20 seconds before the pro gram is going to turn the lights off Press the button again to Tre Ca nce L SAVER AUTO SPEED Thermostatic fan speed control SECURITY Lights ON and OFF automatically REVERSE Change airflow up or down The Winter mode provides draft free recirculation of heated air Press AUTO SECURITY REVERSE to activate and the word WINTER is indicated This puts the fan in th
7. fan body in the canopy hold the fan body firmly and in sert the ball into the canopy opening Check that no wires were pinched Ro tate the fan body until the slot in the ball fits into the pin opposite the canopy opening Fan Hanging Weight is 26 Ibs CANOPY ELECTRICAL CONNECTIONS Step 4a Attach the fan wires to the ceiling fixture outlet box wiring by placing the bare ends of the wires side by side WIRE NUT and then securing with a wire nut Test that the connection is secure by pulling on the wire nut Connect in this order Step 4b e GREEN leads from mounting plate and fan to GROUND con ductor of power source Secure with wire nut e WHITE wire from fan to white NEUTRAL wire in ceiling fixture outlet box Secure with wire nut e BLUE wire and BLACK power wire from fan to BLACK power wire in ceiling outlet box Secure with wire nut CANOPY HATCH INSTALLATION Step 5 Tuck the wires into the canopy with the wire nuts pointed upwards so that the WHITE and BLACK wires are on opposite sides of the canopy and all wires are clear of the canopy opening Step 6 Install canopy hatch with the last canopy screw and lock washer To do this tilt the fan body away from the hatch LOCK D opening WASHER _ Using the screwdriver tighten the screws CANOPY firmly by hand only SCREW TILT THE Step 7 Straighten the fan then check A ye et to ensure that there is no movement be
8. may be used but never use abrasive cleaning agents These will damage the finish Painted and high gloss blades may be cleaned in the same manner Blades Wood finish blades should be cleaned with a furniture pol ishing cloth Occasionally a light coat of furniture polish may be applied for added protection and beauty Never Lubricate this Fan The precision motor at the heart of your Casablanca fan features sealed bearings that are lubricated for life Do not attempt to oil the motor Changing Light Bulbs Be sure to turn power to the fan OFF at the wall switch or circuit breaker before changing light bulbs Replace bulbs with same type as removed from the fixture Each fan is rated for a maximum TOTAL wattage of lighting Exceeding the rated maximum allowable wattage for the fan will burn out the fan electronics module and void the warranty INTELI TOUCH NO FAN OR LIGHT Check main circuit fuses curcuit breakers or wall switch position Check all wire connections making sure the power is turned off during this inspection FAN WOBBLES OR SHAKES EXCESSI VELY Be sure canopy pin is properly set into the slot on the ball Check the screws holding the blade holders to the fan motor Tighten as necessary Check the angle of the blades to make sure that a blade holder has not been bent during installation FAN NOISY DURING OPERATION Check and tighten light fixture retaining screws glass shade screws and or the light bulb
9. wire of light fixture Secure with wire nut Black wire from fan to black wire of light fixture Secure with wire nut Inspect each wire nut and ensure that no bare wire is visible Pull each wire to test the connection is firm D SWITCH HOUSI NG LIGHT FIXTURE WIRES amp WIRE NUTS Step 15 Lift the switch housing to the base of the fan passing the two switch housing screws through the keyholes of the switch housing Turn the switch housing right clockwise to engage the key holes Assure that no wires are pinched Make sure the screws are properly engaged in the key holes then tighten firmly by hand Pass screws through key holes Turn clockwise tighten screws ATTACH LIGHT A Sate Step 16 Attach the the two 8 32 X s screws re moved in Step 13 to the switch housing assembly as shown Make sure to leave Ys space for the light fixture installation BRESCIA GALLERY EDITION LIGHT FIXTURE GLASS S ail ON Step 17 Carefully slide the glass into the light kit as shown GLASS LIGHTKIT ATTACH LIGHT KIT TO FAN S f Hi Step 18 Lift the light fixture to the switch housing run ning the cap screws through the key holes CAUTION Make sure you feed extra wire from the light fixture through the center hole of the switch housing to avoid pinched wires Turn the light fixture left counter clockwise to engage the screws in the key
10. ADE HOLDER INSTALLATI Step 11 Using the screws from the pack attach each blade blade holder assembly to the motor Using the screwdriver tighten securely by hand only Your Brescia fan is equipped with a fly HOLDER wheel that allows for both 4 and 5 SCREWS blade installation The screw holes sur rounded by squares are for 4 blade installation while the screw holes in circles are for 5 blade installation as shown above ATTACH SWITCH HOUSING SCREWS NOTE IF YOU ARE NOT INSTALLING THE LIGHT KIT PLEASE SEE PAGE 10 Step 12 Attach the two 2 5 32 X 9 32 switch housing screws removed in Step 8 to fan motor as shown leaving 1s space for the switch housing installation SWITCH HOUSING SCREWS FROM STEP 8 p Step 13 Locate the switch housing cap assembly and remove the two 8 32 X 3 3 screws holding the cap onto the switch housing Set the cup aside in a safe lo cation you will need it if you ever decide to uninstall the light fixture 8 32 X 3 8 Note Save these two screws they will be used in Step 16 2 6 FAN ANGA INSTALL SWITCH HOUSING Aaa TO LIGHT FIXTURE Step 14 Thread the wires from the light fixture through the center hole of the switch housing as sembly Then attach the ceiling fan wires to the light fixture wires by placing the bare ends of the wires together and securing with a wire nut Connect in this order e White wire from fan to white
11. ALL BRACKET s ANCHOR 4 C C i C rm payee as WALL BRACKET REMOTE CONTROL REMOTE CONTROL BATTERY 3 SCREW 4 W 21 WALL BRACKET Installation of Remote Control Mount control in convenient location The wall mounting bracket for the remote control should be located in a position that is approximately eye level Secure WALL MOUNTING the wall mounting bracket with the 1 4 screws or anchors BRACKET provided making sure it is level with the floor CAUTION DO NOT MOUNT REMOTE CONTROL ON OR NEAR A METAL SURFACE ERRATIC OPERATION WILL OCCUR Changes or modifications not expressly approved in writing by Casablanca Fan Co may void the user s authority to oper ate this equipment This device complies with RSS 210 of Industry Canada Op eration is subject ot the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Remove for handheld or tabletop use Battery Installation PRESET CHANNEL Install three AAA alkaline batteries in the sequence shown and replace the battery compartment cover then press the remote Heal View ob Remote Control control firmly to the wall bracket so that the Velcro pads grip the pads on the rear of the control The remote control can be easily removed at any time should you wish to use it in another location Just give the control a gen
12. D Cer CHANNEL NUMBER Note Always change the remote control channel first The fan channel can only be changed by having the desired channel already set in the re mote control QTD secur reverse J Zo SAVER GES winter b MN SECURITY REVERSE BASE DISPLAY BASE Check To confirm that the control is the BASE 1 Press for 3 seconds until a beep is heard 2 Confirm temperature display shows b 3 Press again to set H bo A SECURITY REVERSE AUXILIARY DISPLAY TWO CONTROLS OPERATING ONE FAN When two controls are used for the same fan we suggest that both controls be set for the same features AUTO SPEED SAVER etc so that performance remains the same as you move from one to the other Re member the fan will only respond to updates from the control that was last operated manually TROUBLESHOOTING COMFORT ToucH COMFORT TOUCH FAN O K NO LIGHT REMOTE CONTROL OF FAN IS ERRATIC SELECTING WINTER MODE CANCELS AUTO SPEED CHANGING SPEED OR DIRECTION CANCELS WINTER FAN APPEARS TO RESPOND TO UNKNOWN SIGNAL CONTROL ALSO OPERATES A SECOND FAN IN HOME TEMPERATURE DISPLAY DOES NOT CHANGE QUICKLY FAN WOBBLES OR SHAKES EXCESSIVELY Check for burned out light bulb Check fan light wires Check batteries installed correctly Install fresh AL
13. KALINE batteries Normal Normal Change channel of control and fan to a number between 49 and 63 Change channel on control and fan Normal Updates only every 2 minutes Make sure hanging ball slot is properly aligned Tighten canopy and mounting crossbar screws Tighten all blade screws Blades must be balanced contact your dealer FAN NOISY DURING OPERATION Tighten glassware and light bulbs Tighten motor housing screws Tighten canopy and mounting crossbar screws DOES NOT RUN ON LOW SPEED If new break in may be required run at higher speed for several days BATTERY LIFE SEEMS SHORT Not using Alkaline batteries Replace with Alkaline batteries TEMPERATURE READINGS Temperature accuracy 3 F FAN DOES NOT RESPOND TO REMOTE CONTROL Power to fan is off wrong remote being used remote channel changed fan receive SET channel changed or fan antenna not receiving See above in locations with two or more fans in different rooms check that controllers are in right rooms change SET channel to match fan change fan SET channel to match remote check antenna connected to RCM check antenna positioned correctly if batteries weak by moving remote close to fan check that remote not laying on metal surface causing weak signal or connect Earth ground to fan FAN APPEARS TO RESPOND TO UNKNOWN SIGNAL OR IS ERRATIC nvalid lower channel SET 2nd remote in area SET to same channel or remote buttons pressed too quickly Be sure SE
14. OWER must be left on to retain a previously set fan speed or light level INTELI e TOUCH OPERATION SPEED CONTROL There are six individual speed settings for the fan each speed is indicated by an audible tone of increasing pitch FAN CONTROL To select the desired fan speed 1 With fan off press and hold the button labeled C Fan The fan blades ON OFF goruna will start rotating at the slowest speed and will increase in steps A momentary press pans 2 Release the button when the desired speed is reached of the FAN button COD The fan speed is now in memory and will automatically come on at the same T speed each time the button is used To maintain this level of speed TO CHANGE SPEED _ turn the fan on by pressing less than one second To lower speed Press and hold FAN turn fan off then on by pressing and holding the button until the button longer than desired speed is reached When the fan is on you may increase the speed by one second pressing and holding the button until the desired speed is reached then release it INTELI TOUCH OPERATION REVERSING AIRFLOW The direction of airflow can be changed from downward to Note A four toned signal indi upward or from upward to downward cates the command was accepted Cue To reverse the airflow by the fan A few seconds later E 1 Make sure the is on the fan will slow t
15. T channel is between 49 and 63 check SET channels of any other remotes at site check if nearby homes have Comfort Touch fans installed remote signal can travel 50 ft and for proper operation of the control you must wait one second between presses AFTER POWER FAILURE FAN AND LIGHTS ARE OFF Normal To immediately restore fan to its original settings press any button Fan will reset itself within about 30 minutes after power is restored when remote sends normal update message to fan WHEN AC POWER IS TURNED ON LIGHT COMES ON OR FAN TURNS Remote control defective remote buttons pressed too soon AC electricity irregularities noise spikes fluctuations or failure Turn off with remote and restart replace remote control unit or wait twenty seconds for electronics warm up check AC electricity for irregularities defective light dimmers noise spikes voltage changes caused by appliances motors supply brown outs or interruptions or storms etc For questions or to locate the nearest Casablanca Authorized Service Center call toll free 1 888 227 2178 or visit us on the web at www CasablancaFanCo com NY 761 Corporate CENTER DRIVE Pomona CA 91768 TOLL Free 888 CASA 1ST 227 2178 www CasablancaFanCo com CopyriGHT 2001 CasaABLANca Fan Company U S PATENT PENDING PRINTED INROC
16. be restored to the fan Button Operation Rapid button pressing causes erratic fan operation For reliable operation of the remote control and fan you must wait ONE SECOND between button presses to allow the radio signal to be transmitted to the fan and received Labeling If you have more than one ComforteTouch fan in your home we suggest you put an ad si hesive room identification label on the back of the control La O SKALA SPACE FOR bels are in the remote control package General Your ComforteTouch remote control uses one of 15 different radio signals to control the fan This channel is set at the factory There may be times when the channel needs to be changed i e e Two fans in the house set to the same causing interference e Two fans are to be operated from one control e Two controls are to operate the same fan see special Dual Remote Control section on the next page LABEL TEST PROGRAM Press the button to activate a two minute program that puts the fan through a complete functional test The test starts with a full screen display then the preset chan nel number before going into a full light fan and reverse exercise Follow the remote control LCD display and com pare it to the actual fan operation to confirm correct operation FAN OPERATION The ComforteTouch fan is contr
17. ch plate from the existing 2 BLACKS gt A emor Ni switch box mince D erie 2 Remove the screws holding the switch in the switch box ZZ W 3 Pull the existing switch from the switch box to expose the ee or 2 GREENS j wire connections Mue 4 Remove the two wires from the switch sLack BLACK 5 Connect the two wires just removed from the switch to Aei aa the W 32 wall control black wire and black white stripe EN wire Secure these connections with wire nuts NECESSARY 6 Install the W 32 in the wall box with the two long screws SEE NOTE provi ded a BLACK WITH w 7 Install the wall plate with the two color matched screws J ine STRIPE Feuack WHITE NOTE If wall control operation is reversed fan switch controls n a a lights and light switch controls fan turn off the power at the breaker or fuse panel then swap the two W 32 black white stripe wires 120V AC FROM LIGHTS FROM LIGHTS BLACK INTELI TOUCH DUAL W 32 INSTALLATION CAUTION Ensure power is turned OFF at the breaker To control the fan and lights from two locations a NEUTRAL VAREN OTE BELOV three way circuit use 2 W 32 wall controls WHITE 1 Remove the screws and switch plate from the ex CREB ek isting switch box and the screws holding the switch in the switch box 2 Pull the existing switch from the switch box to 6rounpb expose the wire connections 3 Determine which wire is connected to the common terminal of the 3 way switch The termi
18. cient clearance for the blades e In bedrooms fans work best when mounted above the foot of the bed e Over pool tables be sure to provide plenty of clearance to avoid damage from pool cues e In low ceiling locations our optional Low Ceiling Adaptor LCA available at extra cost can be used to gain 31 2 e In kitchens be sure to allow for open cupboard doors to clear the fan blades e Do not install a fan close to or over a pool or spa High humidity combined with corrosive gases will destroy the finish and warp the blades ze a DINING ROOM X7 f Fan Size Variable fan speed capability permits the use of a full size 52 fan even in smaller rooms For very large rooms two fans may be needed MAXIMUM ae HANG TRU gt ANGLE 32 Suggested Extension Pole Lengths Ceiling Height Pole Length 8 Standard Standard 6 12 12 18 24 36 48 BLADES MUST BE A MINIMUM OF 7 ABOVE THE FLOOR CO SS ft 7 MINIMUM j va A Z ff a Z When to Use Extension Poles For best performance and best appearance an extension pole should be used with your Casa blanca fan when installing on high cathedral ceilings or sloped ceilings Casablanca offers stan dard poles in increments of 6 up to 5 Custom poles are available in lengths up to 10 See your Authorized Casablanca Dealer for details
19. d has a tapered thread that is designed to lock completely when correctly installed Step B Using the provided allen wrench loosen the set screw several turns to allow installation of the downrod Thread the downrod into the motor coupling until it stops turning this will take at least four and a half full turns Step C Securely tighten the set screw with the provided allen wrench to ensure safe operation of your fan CAUTION Failure to fully lock in the down rod before securely tightening the allen set screw may cause the fan to separate from the downrod during normal operation WIRE NUT 4 CROSSBAR MOUNTING BRACKET Installing a New Ceiling Fixture Outlet Box If you do not have an existing fixture located where you wish to place your Casablanca fan an approved ceiling fixture outlet box must be installed and wired WARNING To reduce the risk of fire electrical shock or personal injury mount to outlet box marked ac ceptable for ceiling fan support using the mounting hardware provided with the outlet box ALLEN WRENCH DOWNROD amp BALL ASSEMBLY GROUND WIRE DOWNROD amp BALL ASSEMBLY ALLEN SET SCREW _ __ MOTOR P COUPLING g ADDITIONAL HARDWARE m A 2a 8 32 ROUNDED C x 8 32 ROUNDED HEAD SCREW 2 HEAD SCREW 2 FLAT WASHER 2 Using Existing Ceiling Fixture Outlet Box After turning the power OFF at its source either circui
20. direction operate in Auto Speed or Winter SECURITY MODE CYCLE use Saver or run the Test mode without affecting Security mode SAVER Lights turn OFF after 1 hour TEST Tests all fan and light functions WINTER Draft free heat recirculation 1 On for 30 minutes 80 bright 5 On for 60 minutes 100 bright 2 Off for 30 minutes 6 Off for 120 minutes 3 On for 120 minutes 50 bright 7 On for 15 minutes 20 bright 4 Off for 60 minutes 8 Off for 60 minutes You may still turn the light ON and OFF or OFF and ON manu ally for temporary lighting but the light will continue to operate automatically at its programmed times Ee COMFORT ToucH Changing the control channel 1 Hold the button down until a tone is heard 2 The temperature display will show the current channel number 3 Press fan up or down buttons to change the number to a unique number from 49 to 63 DO NOT use other channel numbers 4 Push to return to normal operation You will need to repeat this step any time you remove the remote control batteries Record the new channel setting in the space pro vided on the rear label 1 Turn OFF power to the fan for five seconds or longer using the wall switch or circuit breaker 2 Turn the power back ON WAIT 20 SECONDS You have 90 seconds in which to complete step 3 3 Press and hold the and buttons together until the display shows cc for Change Channe
21. e upward airflow direction at the fan s lowest speed Every ten minutes the fan will increase to speed 3 for ten seconds before return ing to the lowest speed Pressing any button on the remote will cancel the WINTER Winter mode except using the light functions SECURITY FEATURE Pressing the button will start the Security lighting pro gram The controller beeps and indicates SECURITY The light will automatically turn ON and OFF in a seemingly random man ner over an eight and a quarter hour programmed cycle that is designed to give the home a lived in look Regardless of the light setting when switching to the Security SECURITY Lights ON and OFF automatically REVERSE Change airflow up or down SAVER Lights turn OFF after 1 hour TEST Tests all fan and light functions WINTER Draft free heat recirculation SECURITY xX N Vd N mode lights on or off dim or bright the lights will increase SEND REVERSE to high brightness and then begin the Security cycle This cycle Ss bee em KA D Rel jes when Lo is displayed AUTO SPEED Thermostatic fan speed control SECURITY Lights ON and OFF automatically REVERSE Change airflow up or down is then repeated continuously until cancelled by pressing the button SECURITY At any time during the Security mode you may adjust the fan speed reverse the
22. holes Step 19 Carefully push the glass aside to access the cap screws Ensure that the screws are properly engaged in the CAP keyholes and tighten firmly by hand SCREWS Step 20 Install the two 100 Watt bulbs Step 21 Carefully slide the glass down into place 100W CAUTION TO REDUCE THE RISK OF FIRE USE MAX TWO 100W A15 INCANDESCENT LIGHT BULBS FAN CONTROLS You may now proceed to y the fan control system for l n e your fan n IntelieTouch CoMFoRT TOuCcH For IntelieTouch wall control operation For ComforteTouch models remote control please see the instructions on Page 11 please see the directions on Page 15 ee a LN COMPAN A NOTE THE FOLLOWING STEPS ARE TO BE PERFORMED ONLY IF YOU ARE NOT INSTALLI NG THE LIGHT KIT SWITCH HOUSING Step Al Locate the switch housing cap assembly and remove the two 8 32 X 3 3 screws holding the cap onto the switch I I housing I i Note Save these two screws they eae amp 5 will be used in Step A5 2 Step A2 Attach the two 2 5 32 X 9 32 switch housing screws removed in Step 8 on Page 6 to fan motor as shown leav ing 1 space for the switch housing installation Step A3 Lift the switch housing run ning the switch housing screws through the keyholes Turn the switch housing right clockwise to engage the keyholes Tighten securely by hand only
23. l then release The control automatically changes the fan channel to the new setting A second remote control can be purchased from your dealer to provide dual remote control of one fan Because the fan could be confused by two controllers signaling different information it is necessary to set a BASE control and an AUXILIARY control The last control manually operated controls the fan Where two remote controls are used to control a single fan they must be set so that BOTH controls are set to the SAME channel e ONE control is made into the BASE control The OTHER control is made an AUXILIARY control All remote controls leave the factory as a BASE Initial remote control settings 1 Set both the controls to operate the fan 2 Select one of the remote controls to be the BASE unit Change the other remote to be used in the room to AUXILIARY 1 Press until a beep is heard Remote displays b 2 Press fan up or down buttons to change the display to A 3 Press again to set The fan will now respond to either of the remotes when pressed Reminder These steps will have to be repeated whenever the batteries are changed When AUTO SPEED SECURITY SAVER or TEST modes are in ef fect at any control Automatic control will only be from the control that was last operated manually REMOTE AUTO SECURITY REVERSE CONTROL Q wer ES
24. n off for at least three seconds This will Light dims to half intensity clear the fan memory ready for programming Fan accelerates to full speed with audio tones 2 Turn on Fan reverses at full speed with audio tones 3 Immediately operate the buttons in the following se Fan operates at full speed quence Fan power is reversed with audio tones Fan turns off with audio tones blades coast for a short FAN LIGHT FAN LIGHT FAN one l l l e Lights turn off FAN lt p C UGHT_ lt gt C_FAN _ lt p C LIGHT _ lt P C FAN l The complete cycle lasts slightly over one minute It will continue to repeat until the is turned off for more than three seconds cancelling the program 2 Inteli Touch The Light Minder program automatically turns OFF the fan mounted lights after two hours an To enter the Light Minder Program e 1 Turn the OFF for at least three seconds 2 Turn the ON 3 Immediately operate the buttons in the following sequence FAN lt gt T T 4 A series of tones indicates this command has been accepted The fan and light will operate normally using the buttons to turn them on and off N Z But if the lights are left on they will automatically shut off after two hours To cancel the Light Minder Program turn the off for three seconds The Safe Exit Program gives you about thirty seconds of light when you
25. nal will be marked on switch BLACK it 4 Remove the wire from the common terminal of the Siek write BLUE BLACK 3 way switch Connect this wire to the remaining WITH STRIPE w_32 TH black white striped wire on the W 32 control Se amen 7 STRIPE cure this splice with a wire nut 5 Remove the two remaining wires from the 3 way IN switch Connect one of these wires to a black wire LINE on the W 32 control Secure the splice with a wire ite e nut The remaining wire is to be connected to the WHITE AP RCICIBEAG other black wire on the W 32 Secure the splice STRIPE brack G me ee with a wire nut 6 Install the W 32 in the wall box with the two long screws provided 120V AC 7 Install the wall plate with the two short color BLACK BLACK matched screws provided 8 Installation of the second W 32 control is identi cal Repeat steps 1 through 7 NOTE If wall control operation is reversed fan switch controls lights and light switch controls fan turn off the power at the breaker or fuse panel then swap the two W 32 black white stripe wires inteli Touch 0 D Pai 6 D 0 D The button is normally left in the on position Always turn the power off during cleaning or servicing the fan and during thunderstorms It wy is also used to exit or enter additional programs P
26. o a stop and E 2 Press the button then reverse direction INTEL e TOUCH OPERATION LIGHT To turn the lights off and on press and release the button for less than one Sod P LIGHT CONTROL To vary the light brightness 1 With lights off press and hold the button After one second ON OFF the lights come on at their lowest level and gradually become brighter A momentary press of oN 2 Release the button when the desired brightness level is reached the LIGHT button The brightness level is now in the fan memory and will automatically come on at the same brightness the next time the button is used To TO CHANGE BRIGHTNESS maintain this level of brightness press the button for less than PRESS AND HOLD ka one second To lower the brightness turn the lights off then press and hold LIGHT BUTTON the button until the desired brightness level is reached When the LONGER THAN ONE light is on you may increase the brightness level by pressing and holding SECOND the button until the desired level is reached then release it AUTOMATIC DEMONSTRATION PROGRAM Programmed into every Inteli Touch Series fan is an Auto A multi tone signal will verify the start of the test program matic Demonstration Program It can be used to fully which proceeds as follows demonstrate and test the operation of the fan e Lights slowly increase to full intensity To enter the demonstration program Fan accelerates to speed three with audio tones 1 Tur
27. of the week To cancel the Home Safe Program turn the off for three seconds The Fan Minder feature will add to your comfort when used in the bedroom The program reduces the speed of the fan each two hour interval to compensate for the cooling night air Fan Minder A To enter the Fan Minder Program ae 1 Turn the off for at least three seconds 2 Turn the on 3 Immediately operate the buttons in the following sequence T T TP 4 The fan controller will respond with three descending tones A timer is now initiated and the fan will reduce one speed for each two hour interval The fan will not however descend below the second lowest speed To cancel the Fan Minder Program turn the off for three seconds You may increase the fan speed by pressing and holding the button until the desired speed is reached then release it y The fan will again reduce one speed for each 2 hour interval CENTER AIRELOIN Inteli Touch TROUBLESHOOTI NG Before Requesting Service Please follow this troubleshooting guide before contacting your dealer for assistance Caring for Finishes For cleaning a soft brush or lint free cloth should be used to prevent scratching the finish A vacuum cleaner brush nozzle can remove heavier dust Surface smudges or an accu mulation of dirt and dust can easily be removed by using a mild detergent and slightly dampened soft cloth An antistatic agent
28. olled by the remote control The fan is turned on and off by alternate pushes of the large right hand button As with all button operations an audio tone sounds with each push With the fan on the control display will indicate an up or down moving arrow that shows direction and places a box around the operating speed The two small and buttons below the fan button increase or decrease speed once for each press The light is turned on and off by alternate pushes of the large left hand button When on the display will indicate the light bulb symbol and a vertical segment display repre senting brightness When the light is on the brightness may be changed by using the small and buttons below the light button Pressing and holding either button will change the brightness continuously Bulb Saver Feature When the light is turned on the brightness is gradually in creased until it reaches the preset level This feature helps extend light bulb life FULL LCD SCREEN DISPLAY x S is aces OS TEST W 21 BUTTON TEMPERATURE FAN ON OFF BUTTON SPEED gt UP DOWN AIRFLOW BUTTONS DI RECTION FAN SPEED LIGHT OPERATION LIGHT Ve Cf MENNENE LIGHT UP DOWN BUTTONS BRI GHTNESS INDI CATOR Additional control program features are available from the con trol panel by o
29. pening the control panel door To activate a control function press the appropriate button the display will indicate that the program is running In some cases you can run more than one program at once such as and and the display will indicate that they are both activated In other cases one program will override another as the two programs can not run together i e and winter Full details are explained in the sections that follow IB AUTO SPEED SECURITY TEST SAVER WINTER Vs Cf LL Camo enn reverse f saver test wire CONTROL PANEL CONTROL PANEL _____ DOOR WINTER Draft o COMFORT TOUCH REVERSE FEATURE Pressing the button will change the direction of rotation An audio tone signals the beginning of the reverse sequence and you will see the airflow direction arrow changing The fan gradually slows to a stop then reverses direction Note This function does not operate if the fan is not running REVERSE AUTO SPEED FEATURE In the Auto Speed mode fan speed changes in response to changes in room tempera ture Push the button to start The words AUTO SPEED show on the display Set TA the fan speed to the speed at which you are most comfortable Once set the fan will shy F aroso Y i J
30. s Tighten canopy screws and mounting plate assembly Tighten the blade to bladeholder screws and blade holders to flywheel Make sure all screws in the motor housing are snug but not overly tight Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have fallen off the wire splices Tighten or adjust as necessary BREAK IN PERIOD DOES NOT RUN ON LOW SPEED Let fan run at high speed for two 2 hours If new break in may be required run at higher speed for several days LIGHTS FLASH OR BLINK DURING OPERATION OF W 32 WALL CONTROLS FAN MAY ROTATE OR MAKE AUDIBLE TONES DURING OPERATION OF THE W 11 AND W 12 WALL CONTROLS Normal operation WHEN AC POWER IS TURNED ON FOR THE FIRST TIME THE LIGHTS OPERATE NORMALLY BUT W 32 WALL CONTROL OPERATION IS REVERSED FAN BUTTON OPERATES THE LIGHTS LIGHT BUTTON OPERATES THE FAN Reverse the 2 black and white striped wire connections FAN OR LIGHTS APPEAR TO OPERATE BY THEMSELVES CHANGING SPEED OR INTENSITY WALL CONTROL OPERATION IS INTERMIT TENT Check AC supply for irregularities noise spikes fluctuations or failure or circuit board assembly For questions or to locate the nearest Casablanca Authorized Service Center call toll free 1 888 227 2178 or visit us on the web at www CasablancaFanCo com COMFORT ToOuCcH a gt O h W
31. should be consulted if you are unsure e This fan is designed to be installed on an existing electrical outlet box The outlet box must be UL Listed for ceiling fan installations if it is not a new box must be installed Casablanca extension poles are available for sloped or high ceiling installations This ceiling fan requires a grounded electrical supply of 120 VAC 60 Hz and a minimum 15 amp circuit The maximum current requirement for the fan with light fixture is 3 8 amps The fan uses about 1 amp or 100 watts Maximum light current is 2 8 amps or 340 watts of lighting Where wire nuts are employed be sure all bare wires are within the connectors When installing the canopy hatch make sure all wires are within the canopy and that no wires are being pinched For best performance and for your warranty to be valid use only genuine Casablanca blades light fixtures and accessories The blades in each pack are matched for equal FUSE BOX weight to assure smooth fan operation If REMOVE FUSE FOR THE more than one fan is being installed be CIRCUIT YOU WILL BE careful not to mix blades from different WORKING ON cartons Inspect the contents of your carton for possible shipping or handling damage and report any such damage directly to your authorized Casablanca dealer Itis always a good idea to have an assistant ae 18
32. t breaker or fuse box lower the old fixture and disconnect the wiring Check the ceiling fixture outlet box to be sure that it is marked Approved for ceiling fan mounting If it is not a new box must be installed Fan Hanging Weight is 26 Ibs i a A Canea S CROSSBAR MOUNTI NG BRACKET INSTALLATI ON Proceed with installation as follows CEILING FAN Step 1 Route the wires from the ceiling outlet box through APPROVED the crossbar mounting bracket center hole Attach the bracket OUTLET BOX with ground wire and ridges down to the ceiling fixture out let box with the mounting hardware included with the outlet box Tighten the screws firmly by hand only being careful not to bend the bracket by over tightening CAUTION To reduce the risk of CROSSBAR personal injury use only the MOUNTI NG mounting hardware provided with the approved outlet box to install the crossbar mounting bracket OUTLET BOX MOUNTI NG HARDWARE T n n CANOPY SCREW 4 CANOPY CANOPY LOCK WASHER 4 HATCH CANOPY INSTALLATION Step 2 Attach the canopy to the crossbar mount ing bracket with three of the 8 32 x 214 long Canopy screws and canopy lock washers Tighten the screw firmly by hand only Note On sloped ceilings align the canopy opening towards the top or room peak CANOPY WASHERS CANOPY SCREWS BRESCIA GALLERY EDITION HANGING THE FAN Step 3 To hang the
33. tle tug to remove it REMEMBER THE REMOTE CONTROL WILL GO BACK TO THE ORI GI NAL FACTORY PRESET CHAN NEL NUMBER WHEN THE BATTERIES ARE CHANGED CHANGE CONTROL CHANNEL IF NEC o Fi o ESSARY AFTER BATTERY REPLACEMENT 4 an 4 ae BATTERIES ONLY ROOM LABEL Low Battery Indicator The remote control warns of a low battery condition by displaying a rapidly flashing Lo L in place of the temperature display When this occurs replace with fresh alkaline battery 0 WARNING Use of batteries other than non leak sealed alkaline in the 9 OD Gm am remote control will void the warranty and can destroy the unit se Cet Coe Note When the remote is in the low battery mode the fan may not respond to Sar meaner control commands correctly even though the fan may be running 7 z ComForT TOuCcH Turning On Your Fan The fan will not receive any signals for the first 20 seconds after power on This allows the electronics to warm up and stabilize hold power failure as it is battery operated Once power is restored to the fan it will receive an auto update signal from the remote control within 30 minutes after power is restored All previously set modes and functions will
34. turn the lights off enabling you to exit your home before the lights go out To enter the Safe Exit Program 1 Turn the off for at least three seconds 2 Turn the on 3 Immediately operate the buttons in the following sequence FAN lt gt al r After you hear the confirming audio tones from the fan immediately press LIGHT _ 4 The lights will blink to indicate this command has been accepted Note Both Light Minder and Safe Exit The lights will stay on for twenty seconds and then begin to dim After a programs can run at the same time total of thirty seconds has elapsed the lights will be off completely To however the dimmer cannot be used cancel the Safe Exit Program turn the off for three seconds the light may only be turned ON OFF The Home Safe Program makes an unoccupied home appear occupied by turning the lights on and off at random times To enter the Home Safe Program 1 Turn the off for at least three seconds 2 Turn the on 3 Immediately operate the buttons in the following sequence P P T 4 A tone and flashing light indicate this command has been accepted This program overrides all manual control of lights and fan The lights will now be automatically cycled on and off in a controlled sequence as follows On 1 hour off 1 2 hour on 2 hours off 1 hour on 2 hour then off 2 hours This seven hour pattern will repeat continuously so that a different pattern of lighting is seen each day