Home
Briggs & Stratton 030241-0 User's Manual
Contents
1. 13 Parada del 19 No sobrecargar el 14 15 Plan de mantenimiento 15 Mantenimiento del generador 15 Mantenimiento del 1 16 Almacenamiento 19 Resoluci n de problemas 20 usc exo cines EN A eee d 21 Garant a del sistema de control de 21 Garant a para el propietario de una generador 23 24 Especificaciones del 24 Servicio COM N 24 Espa ol e gm CD CD ea e SPula q04d Seguridad Seguridad de operario Descripci n del equipo Lea atentamente este manual y familiar cese con el generador Conozca sus aplicaciones limitaciones y riesgos Este generador funciona en base a un motor de campo el ctrico giratorio y de corriente alterna CA Fue dise ado con la finalidad de proveer energ a el ctrica para l mparas el ctricas aparatos herramientas y cargas de motor compatibles El campo
2. 305 cc 18 61 pulgadas Buj a Separaci n 0 030 pulgadas 0 6mm Capacidad de Aceite 0 83 litros 28 onzas servicio com n despide Depurador de aire 4915885 o 5043 Bujia dere stato 4910555 Buj a larga de vida de platino 5066D Botella de aceite de motor 100005 Estabilizador de combustible 5041D ApagachiSDasS 94945 Potencia nominal El valor de potencia bruta de cada modelo de motor de gasolina se indica en la etiqueta conforme a los requisitos del c digo J1940 Procedimiento de valoraci n de potencia y par de pequefios motores de la SAE Society of Automotive Engineers Sociedad de ingenieros de automoci n Los valores nominales se han obtenido y corregido conforme al c digo SAE J1995 Revisi n 2002 05 Los valores de par se obtienen a 3060 rpm y los valores de potencia a 3600 rpm La potencia bruta real del motor ser inferior y depender entre otros factores de las condiciones ambientales de uso y de las variaciones entre distintos motores del mismo modelo Dada la amplia variedad de productos que utilizan nuestros motores y la multitud de factores ambientales que pueden afectar a su funcionamiento es posible que el motor de gasolina no desarrolle toda su potencia bruta nominal en determinados equipos potencia en la aplica
3. ADVERTENCIA Los generadores producen un voltaje muy poderoso Si no a sla el generador de utilidades de energ a puede hacer que los trabajadores de electricidad sufran heridas graves e inclusive la muerte debido a la retroalimentaci n de la energ a el ctrica Cuando use un generador como poder de energ a auxiliar notifique a la compafi a de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad el ctrica Use un interruptor para la falla del circuito de tierra GFCI en cualquier rea bastante h meda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambres pelados o recept culos NO use un generador con cables el ctricos que est n malgastados rotos pelados o da ados de cualquier forma NO opere el generador bajo la lluvia NO maneje el generador o cables el ctricos mientras est parado en agua descalzo o cuando las manos y los pies est n mojados NO permita que personas descalificadas o ni os operen o sirvan al generador ADVERTENCIA La combustible y sus vapores son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras severas e inclusive la muerte CUANDO ANADA COMBUSTIBLE 0 VAC E EL DEP SITO e Apague el generador posici n OFF y d jelo enfriar al menos por 2 minutos antes de remover la tapa de la combustible Afloje la tapa lentamente para dejar que la p
4. NUNCA utilice un generador Util celo solo en el en el interior de una casa o EXTERIOR alejado de un garaje AUNQUE haya ventanas puertas y ventanas y puertas abiertas aberturas de ventilaci n Espa ol aferu Controles y caracter sticas Lea este Manual del Operario y reglas de seguridad antes de poner en marcha su generador L Compare las ilustraciones con su generador para familiarizarse con la ubicaci n de los diversos controles y ajustes Guarde este manual para futuras consultas A Tomacorriente Dobles de 120 Voltios AC 20 Amp Pueden ser utilizados para suministrar alimentaci n el ctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminaci n el ctrica de 120 Voltios AC a 20 Amperios monof sica de 60 Hz B Cortacircuitos AC Cada tomacorriente posee un cortacircuito para proteger el generador contra sobrecargas el ctricas Los cortacircuitos son del tipo oprimir para C Tomacorriente con Dispositivo de Seguridad de 120 240 Voltios 30 Amp Puede ser utilizado para suministrar alimentaci n el ctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminaci n el ctrica de 120 y o 240 Voltios AC a 30 Amperios monof sica de 60 Hz D Conector de Tierra Consulte con el organismo responsable de la normativa vigente de conexi n a tierra E Silenciador Apagachispas El silenciado
5. BRIGGSSSTRATTON 5550 Watt Portable Generator Operator s Manual BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC Printed in U S A Manual 19702365 Revision D 08 08 2007 0124347117954 1 Thank you for purchasing this quality built Briggs amp Stratton generator We are pleased that you ve placed your confidence in the Briggs amp Stratton brand When operated and maintained according to the instructions in this manual your Briggs amp Stratton generator will provide many years of dependable service This manual contains safety information to make you aware of the hazards and risks associated with generator products and how to avoid them This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting appliances tools and motor loads and is not intended for any other purpose It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment Save these instructions for future reference This generator requires final assembly before use Refer to the Assembly section of this manual for instructions on final assembly procedures Follow the instructions completely Where to Find Us You never have to look far to find Briggs amp Stratton support and service for your generator Consult your Yellow Pages There are over 30 000 Briggs amp Stratton authorized service dealers worldwide who provide quality s
6. tornillos y dos nueces del mal de ojo 12 Vuelva a colocar el generador en la posici n normal de funcionamiento apoyado en las ruedas y la pata de soporte aferu Agregar aceite al motor 1 Coloque la generador en una superficie plana y nivelada 2 Limpie la zona de alrededor del orificio de llenado de aceite y quite el tap n amarillo NOTA Consulte la secci n Aceite para ver las recomendaciones relativas al aceite Compruebe que la botella de aceite suministrada tiene la viscosidad adecuada para la temperatura ambiente actual 3 Con la ayuda de un embudo opcional vierta lentamente todo el contenido de la botella de aceite por el orificio de llenado de aceite El tratamiento inadecuado del generador puede da arlo y acortar su vida productiva e NO procure acodar ni empezar el motor antes ha sido atendido a apropiadamente con el aceite recomendado Esto puede tener como resultado una aver a del motor 4 Vuelva a colocar el tap n y apri telo firmemente Agregue combustible El combustible debe reunir los siguientes requisitos e Gasolina sin plomo limpia y nueva e Un m nimo de 87 octanos 87 AKI 91 RON Para uso a gran altitud consulte Gran altitud e El motor admite gasolina con hasta un 10 de etanol gasohol o hasta un 15 de MTBE ter metil terbut lico Evite el da o del generador El fracaso para seguir Manual de Operario para el combustible reccomendations garan
7. operation WARNING e Turn electrical loads OFF and disconnect from generator before stopping generator Starter and other rotating parts can entangle hands hair clothing or accessories NOTICE e NEVER operate generator without protective housing or covers Improper treatment of generator can damage it and e DO NOT wear loose clothing jewelry or anything that may be shorten its life caught in the starter or other rotating parts Use generator only for intended uses e ie up long hair and remove jewelry If you have questions about intended use ask dealer or contact local service center Operate generator only on level surfaces DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT insert any objects through cooling slots Unintentional sparking can result in fire or MM ey roug Ing electric shock If connected devices overheat turn them off and disconnect them from generator Shut off generator if electrical output is lost WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR equipment sparks smokes or emits flames e Disconnect the spark plug wire from the spark plug and place unit vibrates excessively the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK e Use approved spark plug tester e DO NOT check for spark with spark plug removed 6 BRIGGSandSTRATTON COM Assembly LU Read entire operator s manual before you attempt 4 to assemble
8. 12 Starting the Engine 12 Connecting Electrical 0 05 13 Stopping the 19 Don t Overload Generator 14 Maintenance 15 Maintenance 15 Generator Maintenance 15 Engine 16 oro MR 19 Troubleshooting lene 20 21 Emissions Control System 21 Generator Owner Warranty 23 specifications 24 Product 5 lt 24 Common Service 24 Espa ol e c ec cD N e e A Operator Safety Equipment Description A Read this manual carefully and become familiar L with your generator Know its applications its limitations and any hazards involved The generator is an engine driven revolving field alternating current AC generator It was designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads The generator s revolving fi
9. 24 months If gasoline in the engine has not been treated with a fuel stabilizer it must be drained into an approved container Run the engine until it stops from lack of fuel The use of a fuel stabilizer in the storage container is recommended to maintain freshness Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK e Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors WHEN DRAINING FUEL e Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Drain fuel tank outdoors Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke Change Oil While engine is still warm drain oil from crankcase Refill with recommended grade See Changing Engine Oil Oil Cylinder Bore e Remove spark plug and pour about 1 2 ounce 15 ml of clean engine oil into the cylinder e Install spark plug and pull starter handle slowly to distribute oil Unintentional sparking can result in fire or electric shock e NEVER crank engine with spark plug removed Other Storage Tips 1 DO NOT store fuel from one season to another unless it has been treated as described in L
10. Servicio gratuito La reparaci n o sustituci n de toda pieza garantizada se realizar sin cargo alguno para el propietario incluido el trabajo de diagn stico que permita determinar que la pieza garantizada es defectuosa siempre que se realice en un distribuidor autorizado de servicio B amp S En el caso del servicio de garant a de emisiones p ngase en contacto con el distribuidor autorizado de servicio B amp S que figurar en las P ginas Amarillas en la secci n de Motores de gasolina Gasolina motores Cortac spedes o similar Solicitudes y exclusiones de cobertura Las solicitudes de garant a se cumplimentar n con arreglo a las disposiciones de la Pol tica de garant a de motores B amp S La cobertura no incluye los fallos de piezas garantizadas que no sean originales de B amp S ni los fallos debidos al uso indebido o negligente o al mantenimiento inadecuado conforme a las disposiciones de la Pol tica de garant a de motores B amp S B amp S no ser responsable de la cobertura de fallos de piezas garantizadas provocados por el uso de piezas complementarias no originales o modificadas Mantenimiento Los fallos de toda pieza garantizada que no se deba sustituir como parte del plan de mantenimiento obligatorio o que s lo se deba inspeccionar peri dicamente para proceder a su reparaci n o cambio en caso de ser necesario quedar n cubiertos durante el per odo de garant a Los fallos de toda pieza garant
11. marinas El uso de un generador no homologado por cuerpo de guardacostas de EE UU puede provocar lesiones y da os materiales Espa ol pepiunbas Seguridad Ah ADVERTENCIA PRECAUCI N El contacto con la zona del silenciador puede Las velocidades de operaci n en exceso aumentan los e producir quemaduras graves riesgos de heridas y da os al generador Los gases y el calor de escape pueden inflamar Las velocidades bajan en exceso imponen una carga muy 2 los materiales combustibles y las estructuras o pesada Y da ar el dep sito de combustible y provocar un e NO cambie ninguna velocidad determinada El generador incendio suministra una frecuencia y un voltaje calificado cuando NO toque las superficies calientes y EVITE los gases del escape funciona a una velocidad determinada a alta temperatura e NO modifique al generador en ninguna forma Permita que el equipo se enfr e antes de tocarlo generador incluida la parte superior El C digo de Normativa Federal T tulo 36 Parques TO Bosques y Propiedad P blica obliga a instalar una pantalla generador puede da ar al generador y los aparatos apagachispas en los equipos con motor de combusti n interno el ctricos conectados al mismo y a mantenerla en buenas condiciones de funcionamiento Vea No sobrecargue generador conforme a la norma 5100 16 0 posterior del Servicio Forestal Encienda su generador y deje que el motor se estabilice
12. plana 2 Compruebe el nivel de aceite tal como se indica en la secci n Comprobaci n del nivel de aceite 3 Si es necesario vierta lentamente aceite por el orificio de llenado hasta el punto de desbordamiento en el tap n de llenado de aceite 4 nstale el tap n de llenado de aceite apriete firmemente Cambio de aceite del motor Cambie el aceite despu s de las primeras 5 horas de operaci n Cambie el aceite cada 50 horas de ese momento en adelante Si est utilizando su generador bajo condiciones de extrema suciedad o polvo o en un clima demasiado caliente haga el cambio de aceite m s frecuentemente Evite el contacto prolongado o repetido de piel con aceite usado de motor e El aceite usado del motor ha sido mostrado al cancer de la piel de la causa en ciertos animales del laboratorio Completamente lavado expuso reas con el jab n y el agua MANTENER FUERA DEL ALCANCE DE LOS NINOS NO CONTAMINE CONSERVE LOS RECURSOS DEPOSITE EL ACEITE USADO EN UN PUNTO DE RECOGIDA BRIGGSandSTRATTON COM Cambie el aceite cuando el motor siga estando caliente 2 Con cuidado quite cartucho F de base G despu s de haber funcionado 3 Instale limpie o nuevo aire la asamblea m s limpia 1 Aseg rese de que la unidad est en una superficie dentro de la cubierta Desh gase del filtro viejo plana apropiadamente 2 Desconecte el cable de la buj a de esta y col quelo 4 Arme la cubierta m s limpia a rea en l
13. Necesitar las herramientas para instalar estos componentes e 2 Llaves de 13 mm y 7 16 e Llaves de cubo de 13 mm y 7 16 e Alicates e Gafas de seguridad Instale el juego de ruedas conforme a las instrucciones siguientes 1 Dele la vuelta al generador de forma que el motor quede arriba 2 Introduzca el eje A a trav s de los dos soportes de montaje 3 Coloque una rueda B en cada extremo cuando mostrado 4 Introduzca una arandela C por el eje y coloque una anilla en 6 1 e D en la ranura del eje Las anillas en e pueden salir disparadas durante el montaje o el desmontaje 5 Para ello apriete con unos alicates desde la parte superior de la anilla en hacia la parte inferior del eje 6 Repita los pasos 4 y 5 para asegurar la segunda rueda 7 Dele la vuelta al generador de forma que el lado del motor quede abajo 8 Instale los montajes antivibratorios E a la pata de soporte F utilizando dos tornillos prisioneros 1 4 20 x 1 G y 1 4 20 tuercas de seguridad H 9 Quite el hardware existente del monte izquierdo de la vibraci n de la unidad con 13mm llave inglesa Use el mismo hardware para conectar la pierna de apoyo 10 Conecte el otro lado de la pata de soporte con un M8 x 20 mm tornillo de la tapa J y M8 nuez de cerradura 11 Centre el asidero L que levanta en el fin del generador de cuna Conecte el asidero que usa dos 13 mm llaves inglesas con dos 45
14. V del generador Examine los cables prolongadores antes de cada uso Revise las capacidades de todos las cordones de extensi n antes de usarlos Los juegos de cordones de extensi n utilizados deber n tener una capacidad de 125 Voltios AC a 20 Amperios o mayor para la mayor a de los dispositivos el ctricos Sin embargo algunos dispositivos podr an no requerir este tipo de cord n de extensi n Revise el manual del propietario de esos dispositivos para ver las recomendaciones del fabricante Utilice cables prolongadores de la menor longitud posible para reducir al m nimo la ca da de tensi n ADVERTENCIA Los cables el ctricos sobrecargados pueden recalentarse formar un arco o quemarse provocando la muerte lesiones y o da os materiales e Utilice exclusivamente cables regulados para las cargas aplicadas e Respete todas las medidas de seguridad de los cables el ctricos Dispositivo de seguridad de 120 240 V 30 A Use un tap n NEMA L14 30 con este recept culo Conecte un juego de cable de 4 alambres clasificado como 250 Voltios AC a 30 Amps o mayor Usted puede usar el mismo cable de 4 alambres si planea trabajar con una carga de 120 Voltios Juego de Cable de 4 Alambres 120V W Neutro Y Cargado X Cargado NEMA L14 30 L Tierra Verde Este recept culo le provee poder a cargas de 120 240 Voltios AC de 60 Hz fase sencilla que requieren hasta 2 775 vatios de energ a a 23 1 Amperios
15. and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material NOTE DO NOT use water or other liquids to clean generator Liquids can enter engine fuel system causing poor performance and or failure to occur In addition if liquid enters generator through cooling air slots some of the liquid will be retained in voids and cracks of the rotor and stator winding insulation Liquid and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings Cleaning Daily or before use look around and underneath the generator for signs of oil or fuel leaks Clean accumulated debris from inside and outside the generator Keep the linkage spring and other engine controls clean Inspect cooling air slots and openings on generator These openings must be kept clean and unobstructed Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris e Use a damp cloth to wipe exterior surfaces clean NOTICE Improper treatment of generator can damage it and shorten its life DO NOT expose generator to excessive moisture dust dirt or corrosive vapors e DO NOT insert any objects through cooling slots Use a soft bristle brush to loosen caked on
16. descon ctelas del generador antes de parar el generador Espa ol No sobrecargar el generador Capacidad Debe asegurarse de que su generador puede proveer los suficientes vatios de potencia continua vatiaje nominal y vatios de salida para los elementos que desee alimentar al mismo tiempo Siga estos sencillos pasos 1 Seleccione los elementos que quiere alimentar al mismo tiempo 2 Sume la potencia nominal de esos elementos Esa es la cantidad de energ a que su generador debe producir para mantener sus elementos en funcionamiento Vea Gu a de Referencia de Potencia 3 Calcule cu ntos vatios de salida necesitar La potencia de salida se refiere al corto arranque de energ a que se necesita para arrancar herramientas o dispositivos a motor como una radial o un refrigerador Como no todos los motores arrancan al mismo tiempo el total de vatios de salida puede calcularse a adiendo s lo el elemento con la potencia de salida m s alta al total de vatios de potencia continua que obtuvimos en el paso 2 Ejemplo Vatios Calificados cuando Vatios Adicionales de est funcionando Carga al encender Aire Acondicionado de Ventana 1200 1800 Herramienta o Aparato El ctrico Refrigerador 1600 Congelador industrial 500 Televisi n Luz 75 Vatios Total 3075 Vatios 1800 Vatios de funcionar Carga m s alto Vatios de potencia continua totales 3075 Potencia de salida adicional mas alta 1800
17. estabilizador de combustible en el contenedor de almacenamiento para mantener la gasolina en buen estado ADVERTENCIA La combustible y sus vapores son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras severas e inclusive la muerte CUANDO ALMACENE O GUARDE EL EQUIPO CON COMBUSTIBLE EN EL TANQUE e Almacene alejado de calderas estufas calentadores de agua secadoras de ropa u otros aparatos electrodom sticos que posean pilotos u otras fuentes de ignici n porque ellos pueden encender los vapores de la combustible CUANDO VAC E EL DEP SITO e Apague el generador posici n OFF y d jelo enfriar al menos por 2 minutos antes de remover la tapa de la combustible Afloje la tapa lentamente para dejar que la presi n salga del tanque Vac e el dep sito de combustible a la intemperie Mantenga la combustible alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n NO encienda un cigarrillo o fume Cambio de aceite Con el motor todav a caliente drene el aceite de la caja del cigue al Vuelva a llenarlo con el grado de aceite recomendado Aceite el di metro interior del cilindro e Quite la buj a y vierta aproximadamente 15 ml 1 2 onza de aceite de motor limpio en el interior del cilindro e Coloque la buj a y arranque lentamente para distribuir el aceite AX ADVERTENCIA 7 9 Chispear involuntario puede tener resultado el fue
18. of California a spark arrester is required under section 4442 of the California Public resources code Other states may have similar laws 1 To remove muffler heat shield A from muffler B remove four screws that connect guard to muffler bracket 2 Remove four screws that attach spark arrester screen C 3 Inspect screen and obtain a replacement if torn perforated or otherwise damaged DO NOT use a defective screen If screen is not damaged clean it with commercial solvent 4 Reattach screen and muffler guard 17 92ueua ure Maintenance Air Cooling System Over time debris may accumulate in cylinder cooling fins and cannot be observed without partial engine disassembly For this reason we recommend you have an authorized service dealer clean the cooling system A per recommended intervals see Maintenance Schedule in beginning of Maintenance section Equally important is to keep top of engine free from debris See Clean Debris Re d WOK 18 Check Valve Clearance Regular valve clearance check and adjustment will improve performance and extend engine life This procedure cannot be done without partial engine disassembly and the use of special tools For this reason we recommend that you have an authorized service dealer check and adjust valve clearance at recommended intervals see Maintenance Schedule in the Maintenance section Carburetor Adjustment The carburetor on this engi
19. or higher is an acceptable oil at all temperatures Use of synthetic oil does not alter required oil change intervals 16 Checking Oil Level Oil level should be checked prior to each use or at least every 8 hours of operation Keep oil level maintained 1 Make sure generator is on a level surface 2 Clean area around oil fill and remove oil fill cap 3 Verify oil is at the point of overflowing at oil fill opening 4 Replace and tighten oil fill cap Adding Engine Oil 1 Make sure generator is on a level surface 2 Check oil level as described in Checking Oil Level 3 If needed slowly pour oil into oil fill opening to the point of overflowing at oil fill 4 Replace and tighten oil fill cap Changing Engine Oil Change the oil after the first 5 hours of operation Change oil every 50 hours thereafter If you are using your generator under extremely dirty or dusty conditions or in extremely hot weather change the oil more often A CAUTION Avoid prolonged or repeated skin contact with used motor oil Used motor oil has been shown to cause skin cancer in certain laboratory animals e Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Change the oil while the engine is still warm from running as follows 1 Make sure unit is on a level surface 2 Disconnect the spark plug wire from the
20. or operate your new generator Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil If you have any problems with the assembly of your generator please call the generator helpline at 800 743 4115 If calling for assistance please have the model revision and serial number from the data tag available See Generator Controls and Features for data tag location Unpack Generator 1 Set the carton on a rigid flat surface 2 Remove everything from carton except generator 3 Open carton completely by cutting each corner from top to bottom 4 Leave generator on carton to install wheel kit The generator is supplied with e Operators manual e Oil bottle e Wheel kit Install Wheel Kit NOTE Wheel kit is not intended for over the road use You will need the following tools to install these components e 2 13mm and 7 16 wrenches e Socket wrench with 13mm and 7 16 sockets e Pliers e Safety glasses Install the wheel kit as follows 1 Slide axle A through both mounting brackets Place a wheel B on each side as shown below Place a washer C on axle and then place an e ring D I 0 N D 10 11 12 Tip generator so that engine end is up in axle groove A CAUTION E rings can cause eye injury E rings can spring back and become airborne when installing or removing Install e ring with pliers sque
21. para 120 Voltios 5 550 vatios de energ a 5 55 kW a 23 1 Amperios para 240 Voltios La salida est protegida por un corto circuito de del tipo empuje para reposicionar Las tomas el ctricas pueden marcar un valor nominal mayor que la capacidad de salida del generador e NUNCA intente conectar un dispositivo que requiera m s amperaje del que el generador o la toma el ctrica pueden suministrar e NO sobrecargar el generador V ase No sobrecargar el generador Tomas el ctricas dobles de 120 V CA y 20 A Cada recept culo est protegido en contra de sobrecargas por un corto circuitos de del tipo empuje para reposicionar Use cada recept culo para operar 120 Voltios AC de fase sencilla de cargas de 60Hz que requieren hasta 2 400 vatios 2 4 kW a corrientes de 20 Amps Use los juegos de cables que son calificados para cargas de 125 Voltios AC a 20 Amps o mayores Espa ol Operando Encienda el motor Desconecte todas las cargas el ctricas del generador Use las siguientes instrucciones para encender 1 Aseg rese de que la unidad est en una superficie plana IMPORTANTE Si la unidad no se arranca y utiliza en una superficie plana se pueden producir problemas de arranque y de parada durante el funcionamiento 2 Gire la v lvula del combustible a la posici n On El asidero de la v lvula del combustible debe ser vertical se alar hacia el suelo para el combustible para fluir 3 Mu
22. sin el s mbolo de alerta AVISO indica una situaci n que podr a producir da os en el equipo Siga en todo momento los mensajes de seguridad para evitar O reducir el riesgo de lesiones y de muerte El fabricante no puede anticipar todas las posibles circunstancias que podr an conllevar peligro Por lo tanto las advertencias de este manual as como las etiquetas y placas de la unidad no incluyen todo Si usa un procedimiento m todo de trabajo o t cnica operativa que no est espec ficamente recomendada por el fabricante debe asegurarse de que no entra a peligro para usted ni para otras personas Tambi n debe asegurarse de que el procedimiento m todo de trabajo o t cnica operativa elegida no hace que el generador deje de ser seguro S mbolos de peligro y sus significados A Explosi n B Fuego C Descarga El ctrica D Gases T xicos E Retroceso F Superficie Caliente G Objets volant H Partes en Movimiento J Manual del Operario A PELIGRO El uso de un generador un espacio interior PUEDE PROVOCAR LA MUERTE EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono un veneno invisible e inodoro NUNCA utilice un generador Util celo solo en el en el interior de una casa o EXTERIOR alejado de un garaje AUNQUE haya ventanas puertas y ventanas y puertas abiertas aberturas de ventilaci n ADVERTENCIA Al motor funcionar se produce mon xido de ca
23. 97 deben cumplir normas similares determinadas por la U S EPA B amp S debe garantizar el sistema de control de emisiones de su motor durante los per odos que se indican a continuaci n siempre que no se haya hecho un uso indebido o negligente ni un mantenimiento inadecuado del peque o motor para m quinas de servicio El sistema de control de emisiones incluye las siguiente piezas carburador filtro de aire sistema de encendido conducto de combustible silenciador y convertidor catal tico Tambi n puede incluir conectores y otros conjuntos relacionados con las emisiones 51 se cumplen las condiciones de la garant a B amp S reparar el motor sin coste alguno incluido el diagn stica las piezas y la mano de obra Cobertura de la garant a contra defectos del sistema de control de emisiones de Briggs amp Stratton Los pequefios motores para m quinas de servicio est n garantizados contra defectos de las piezas de control de emisiones durante un per odo de dos a os conforme a las siguientes disposiciones Si cualquier pieza del motor con cobertura es defectuosa ser reparada o sustituida por B amp S Responsabilidades de la garant a del propietario Como propietario del peque o motor para m quinas de servicio usted es responsable de la correcta realizaci n de las operaciones de mantenimiento que se enumeran en las Instrucciones de uso y mantenimiento B amp S recomienda conservar todas las facturas relativas al mantenim
24. C Fecha de entrada en vigor 1 de Febrero de 2006 Sustituye a todas las garantias sin fecha y a las de fecha anterior al 1 Febrero de 2006 GARANTIA LIMITADA Briggs amp Stratton Power Products Group LLC reparara sustituira sin cargo alguno cualquier componente del generador portatil que presente defectos de materiales y o mano de obra Los gastos de transporte de las producto enviadas para reparar o sustituir conforme a los t rminos de esta garant a correr n a cargo del comprador El periodo de vigencia y las condiciones de esta garant a son los que se estipulan a continuaci n Para obtener servicio en garant a localice el distribuidor de servicio autorizado m s pr ximo en nuestro mapa de distribuidores en www BRIGGSandSTRATTON COM NO EXISTE NINGUNA OTRA GARANT A EXPL CITA LAS GARANT AS IMPL CITAS INCLUIDAS LAS DE COMERCIABILIDAD O IDONEIDAD PARA UN FIN CONCRETO SE LIMITAN A UN A O DESDE LA FECHA DE COMPRA AL L MITE DE TIEMPO PERMITIDO POR LA LEY QUEDAN EXCLUIDAS TODAS LAS GARANT AS IMPL CITAS QUEDA EXCLUIDA LA RESPONSABILIDAD POR DA OS SECUNDARIOS Y DERIVADOS HASTA EL L MITE PERMITIDO POR LA LEY Algunos pa ses o estados no permiten limitar la duraci n de una garant a impl cita ni excluir o limitar los da os secundarios y derivados Por tanto es posible que las limitaciones y exclusiones mencionadas no sean aplicables en su caso Esta garant a le otorga determinados derechos legales y es posible que tenga otros derech
25. Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death WHEN ADDING OR DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion If fuel spills wait until it evaporates before starting engine Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke WHEN STARTING EQUIPMENT e Ensure spark plug muffler fuel cap and air cleaner are in place e DO NOT crank engine with spark plug removed WHEN OPERATING EQUIPMENT tip engine or equipment at angle which causes fuel to Spill e his generator is not for use in mobile equipment or marine applications WHEN TRANSPORTING OR REPAIRING EQUIPMENT e ransport repair with fuel tank EMPTY or with fuel shutoff valve OFF e Disconnect spark plug wire WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK e Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors e This generator does not meet U S Coast Guard Regulation 33CFR 183 and should not be used on marine applications e Failure to use the appropriate U S Coast Guard approved generator could result in death or serious in
26. Salida total del generador requerida 4875 Control de la energia Para prolongar la vida de su generador y los aparatos que conecte a l es muy importante tener cuidado cuando se le a aden cargas el ctricas No deber haber nada conectado a las tomas del generador antes de encender el motor El modo seguro y correcto de gestionar la energ a del generador es a adir las cargas secuencialmente como se indica a continuaci n 1 Sin tener nada conectado al generador encienda el motor tal como se describe en este manual 2 Conecte y encienda la primera carga preferiblemente la mayor que usted tenga 3 Permita que la salida del generador se estabilice el motor funciona suavemente y el aparato funciona adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 14 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA a ada cargas que sobrepasen la capacidad del generador Tenga especial cuidado en contar con las cargas adicionales en la capacidad del generador como se describe arriba Gu a de Referencia de Potencia Vatios de potencia Vatios de potencia de salida adicional E 800 Refrigerador Congelador 18 pies c bicos Bomba de agua 1 3 HP 1000 az Calefacci n Aire Acondicionado aly acondicionado de ventana 10 000 1200 1800 Ventilador de caldera 1 2 HP 1300 Horno microondas 1000 vatios 1000 Caf
27. a base y apriete donde no pueda entrar en contacto con la buj a los tornillos 3 Limpie la zona de alrededor del tap n de vaciado de aceite A situado en la base del motor al otro lado del dua carburador Cambie la buj a cada 100 horas de funcionamiento o una vez al a o lo que suceda antes Esto ayudar a su motor a arrancar m s f cilmente y funcionar mejor 1 Limpie la zona de alrededor de la buj a 2 Retire e inspeccione la buj a 3 Compruebe la separaci n del electrodo con un calibrador de alambre y ajuste el espacio de la buj a a la medida recomendada si fuera necesario v ase Especificaciones 4 Quite el tap n de llenado de aceite y vac e todo el aceite en un recipiente adecuado OLLE T i 4 E mr Y 6 Vierta lentamente unos 0 83 litros 28 onzas de aceite AN por el orificio de llenado B hasta el punto de NS desbordamiento C NO a ada aceite en exceso 7 Vuelva a colocar el tap n de llenado de aceite Apri telo 4 Cambie la buj a si los electrodos est n picados 0 firmemente a mano quemados o si la porcelana est agrietada Utilice la buj a de repuesto recomendada Consulte Especificaciones 8 Limpie los residuos de aceite 7 a 5 Instale la buj a y apriete firmemente Servicio del depurador de aire Limpie la Pantalla Apagachispas Si se utiliza con un filtro de aire sucio el motor no p pag p funcionar correctamente y puede sufri
28. a garant a de motores de B amp S para motores no regulados que figura en el Manual del Operario 1 Piezas garantizadas La presente garant a cubre nicamente las piezas que se enumeran a continuaci n piezas del sistema de control de emisiones siempre que tales piezas estuvieran presentes en el motor adquirido a Sistema de regulaci n de combustible e Sistema de enriquecimiento para arranque en fr o estrangulador electr nico e Carburador y piezas internas e Bomba de combustible e Conducto de combustible acoplamientos del conducto de combustible abrazaderas e Dep sito de combustible tap n y cadena e Bote de carbono b Sistema de inducci n de aire e Filtro de aire e Colector de admisi n e Linea de purga y ventilaci n Sistema de encendido e Buj a s e Sistema de encendido magn tico d Sistema catalizador e Convertidor catal tico e Colector de escape e Sistema de inyecci n de aire o v lvula de impulso Espa ol a e Elementos diversos utilizados en los sistemas anteriores e V lvulas y conmutadores de aspiraci n temperatura posici n y temporizados e Conectores y unidades 2 Duraci n de la cobertura 22 B amp S garantiza al propietario inicial y a cada comprador posterior que las piezas garantizadas no tendr n defectos de materiales ni de mano de obra que provoquen su fallo durante un per odo de dos a os a partir de la fecha de entrega del motor a su comprador
29. aci n Cada 250 horas o una vez al a o e Compruebe la holgura de la v lvula 1 Servicio m s a menudo bajo condiciones de suciedad o polvo Recomendaciones Generales El mantenimiento peri dico mejorar el rendimiento y prolongar la vida til del generador Acuda a un distribuidor autorizado para reparar la unidad La garant a del generador no cubre los elementos que hayan sido sujetos al abuso o negligencia del operador Para recibir el valor completo de la garant a el operador deber mantener el generador de la forma descrita en este manual Se deber n llevar a cabo algunos ajustes peri dicamente para mantener correctamente su generador Todos los ajustes de la secci n Servicio y Ajustes de este manual deber n ser hechos por lo menos una vez en cada estaci n Cumpla con los requisitos de la tabla Plan de Mantenimiento descrita anteriormente NOTA Una vez al a o deber limpiar o reemplazar la buj a y reemplazar el filtro de aire Una buj a nueva y un filtro de aire limpio garantizan una mezcla de combustible aire adecuada y ayuda a que su motor funcione mejor y tenga una vida til m s prolongada Control de emisiones Cualquier establecimiento o individuo especializado en la reparaci n de motores que no sean de automoci n puede encargarse del mantenimiento la sustituci n y la reparaci n de los dispositivos y sistemas de control de emisiones No obstante para realizar la revisi n gratuita de
30. ads D Grounding Fastener Consult your local agency having jurisdiction for grounding requirements in your area E Spark Arrester Muffler Exhaust muffler lowers engine noise and is equipped with a spark arrester screen F Data Tag Provides model revision and serial number of generator Please have these readily available when calling for assistance 10 Lo ry Leg DN M M G Engine Identification Provides model type and code of engine Please have these readily available if calling for assistance H Air Cleaner Protects engine by filtering dust and debris out of intake air J Choke Lever Used when starting a cold engine K Fuel Tank Capacity of five 7 U S gallons 26 5 L Items Not Shown Engine Rocker Switch Set this switch to On before using recoil starter Set switch to Off to stop engine Fuel Valve Used to turn fuel supply on and off to engine Oil Drain Plug Drain engine oil here Oil Fill Cap Check and fill engine with oil here Recoil Starter Used to start the engine BRIGGSandSTRATTON COM Cord Sets and Receptacles Use only high quality well insulated grounded extension cords with the generator s 120 Volt duplex receptacle Inspect extension cords before each use Check the ratings of all extension cords before you use them Extension cord sets used should be rated for 125 Volt loads at 20 Amps or greater for most electrica
31. andby power to a building s electrical system must be made by a qualified electrician The connection must isolate the generator power from utility power or other alternative power sources and must comply with all applicable laws and electrical codes Generator produces hazardous voltage Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy When using generator for backup power notify utility company Use approved transfer equipment to isolate generator from electric utility Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator Generator Location Clearances and Air Movement structures or damage fuel tank causing a fire 4 Exhaust heat gases can ignite combustibles e Keep at least 5 ft 1 5 m clearance on all sides of generator including overhead Place generator outdoors in an area that will not accumulate deadly exhaust gas DO NOT place generator where exhaust gas A could a
32. antes de la USDA En el Estado de California la ley exige el uso de una de conectar las cargas el ctricas pantalla apagachispas Secci n 4442 del C digo de Recursos I P blicos de California En otros estados puede haber leyes Conecte las cargas el ctricas en la posici n de apagado OFF l luego encienda ON para su operaci n similares en vigor id Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generador AX ADVERTENCIA El arrancador y otras piezas que rotan pueden AVISO enredar las manos el pelo la ropa o los El tratamiento inadecuado del generador puede da arlo y e NUNCA utilice la generador sin sus carcasas o tapas de Use el generador solamente con la finalidad para el cual fue protecci n dise ado NO use ropa suelta joyas o elementos que puedan quedar En caso de dudas sobre su uso dir jase al distribuidor atrapados en el arranque o en otras partes rotatorias e Ate para arriba el pelo largo y quite la joyer a Opere el generador solamente en superficies niveladas NO exponga al generador a una humedad excesiva polvo suciedad o vapores corrosivos NO inserte cualquier objeto a trav s de las ranuras de enfriamiento Si los aparatos conectados se sobrecalientan ap guelos y Chispear involuntario puede tener como descon ctelos del generador resultado el fuego o el golpe el ctrico Apague el generador si pierde la salida el ctrica El equipo p
33. ccumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other openings that can allow exhaust gas to collect in a confined area Prevailing winds and air currents should be taken into consideration when positioning generator A DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents quiassy Features and Controls L Read this Operator s Manual and safety rules before operating your generator Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments Save this manual for future reference A 120 Volt AC 20 Amp Duplex Receptacles May be used to supply electrical power for the operation of 120 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads B Circuit Breakers AC Push to reset circuit breakers are provided to protect the generator against electrical overload C 120 240 Volt AC 30 Amp Locking Receptacle May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp single phase 60 Hz electrical lighting appliance tool and motor lo
34. ceptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up to 2 400 watts 2 4 KW at 20 Amps of current Use cord sets that are rated 125 de loads at 20 Amps or greater Inspect cord sets before each use Operation Operation Starting the Engine Disconnect all electrical loads from the generator Use the following start instructions 1 Make sure unit is on a level surface IMPORTANT Failure to start and operate the unit on a level surface will cause the unit not to start or shut down during operation 2 Turn the fuel valve to the On position The fuel valve handle should be vertical pointing toward the ground for fuel to flow 12 5 Grasp recoil handle and pull slowly until slight resistance is felt Then pull rapidly one time only to start engine e If engine starts proceed to step 7 e If engine fails to start proceed to step 6 Starter cord kickback rapid retraction can result in bodily injury Kickback will pull hand and arm P toward engine faster than you can let go Broken bones fractures bruises or sprains could result e When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback e NEVER start or stop engine with electrical devices plugged in and turned on 6 Move choke lever to Half choke position and pull recoil handle twice e fengine fails to start repeat steps 5 thru 7 7 Slowly move choke leve
35. ci n o neta real Esta diferencia se debe entre otros a los siguientes factores accesorios filtro de aire escape carga refrigeraci n carburador bomba de combustible etc limitaciones de la aplicaci n condiciones ambientales de uso temperatura humedad altitud y variaciones entre distintos motores de un mismo modelo Briggs amp Stratton podr sustituir el motor de esta serie por otro de mayor potencia nominal en caso de limitaciones de fabricaci n o capacidad Briggs amp Stratton Power Products Group LLC 900 N Parkway Jefferson Wisconsin 53549 U S A 24 800 743 4115 BRIGGSandSTRATTON COM
36. cluidos de esta garant a el desgaste de los art culos tales como juntas t ricas filtros etc o los da os derivados de accidentes uso indebido modificaciones alteraciones servicio inadecuado congelaci n o deterioro qu mico Los accesorios tales como empezar bater as juego de cables del adaptador del generador y cubiertas para almacenamiento quedan excluidos de la garant a del producto Tambi n se excluyen los equipos usados o reacondicionados y los destinados a demostraciones los equipos utilizados como fuente principal de energ a en lugar de un servicio p blico y los equipos sanitarios destinados al mantenimiento de las constantes vitales Esta garant a excluye los fallos debidos a hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabricante 198189S Rev B 12 31 2006 BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WI EE UU Espa ol 2 BRIGGSSSTRATTON Generador Port til Especificaciones del producto Vataje que Empieza 8 990 Vatios 8 55 kW Po 9 990 Vatios 5 55 kW Corriente Carga de C A 120 Volti0S 46 2 Amperios 240 Voltios 23 1 Amperios Frecuencia Nominal 60Hz a 3600 rpm PASO wane tuu sar Vor WO ed d tetra Re ad QE Monof sica Capacidad de Gasolina 26 5 L 7 galones americanos Peso que Embarca 68 kg 150 Ibs Desplazamiento
37. control de emisiones deber acudir a un distribuidor autorizado por el fabricante V ase Garant a de emisiones Mantenimiento del generador El mantenimiento del generador consiste en conservar la unidad limpia y seca Opere y almacene la unidad en un ambiente limpio y seco donde no ser expuesta al polvo suciedad humedad o vapores corrosivos Las ranuras del aire de enfriamiento del generador no deben estar tapadas con nieve hojas o cualquier otro material extra os NOTA NO utilice agua u otros l quidos para limpiar el generador Los l quidos pueden penetrar en el circuito de combustible del motor y provocar p rdidas de rendimiento o fallos Asimismo si penetran l quidos en el generador a trav s de las ranuras del aire de refrigeraci n parte del l quido puede permanecer en los huecos y rendijas del aislamiento del devanado del rotor y del estator El l quido y la acumulaci n de suciedad en los devanados internos del generador pueden reducir la resistencia del aislamiento Limpieza Limpie a diario o antes de cada uso los residuos acumulados en el generador Mantenga limpias las conexiones los muelles y los mandos Limpie todo resto de combustible de la zona que rodea al silenciador y de detr s del mismo Inspeccione las ranuras para aire de enfriamiento y la apertura del generador Estas aperturas deber n mantenerse limpias y despejadas Mantenga limpios los componentes del generador para reducir el riesgo de sob
38. cuados De manera similar la garant a quedar anulada si se ha borrado la fecha de fabricaci n o el n mero de serie del generador port til o si el equipo ha sido alterado o modificado Durante el per odo de garant a el distribuidor de servicio autorizado podr reparar o sustituir a su libre elecci n cualquier pieza que previa inspecci n sea defectuosa en condiciones normales de uso y servicio Esta garant a no cubre las reparaciones y equipos que se detallan a continuaci n Desgaste normal Al igual que cualquier otro aparato mec nico los equipos de uso en exteriores necesitan piezas y mantenimiento peri dicos para funcionar correctamente Esta garant a no cubre las reparaciones cuando el uso normal haya agotado la vida til de una pieza concreta del equipo Instalaci n y mantenimiento Esta garant a no cubre los equipos ni las piezas cuya instalaci n sea incorrecta o no haya sido autorizada ni aquellos que hayan sido objeto de cualquier tipo de alteraci n mal uso negligencia accidente sobrecarga exceso de velocidad o mantenimiento reparaci n o almacenamiento inadecuados que a nuestro juicio haya afectado negativamente a su funcionamiento y su fiabilidad La garant a tampoco cubre el mantenimiento normal como los filtres de aire los ajustes y la limpieza o la obstrucci n del sistema de combusti n debido a materias qu micas suciedad carb n cal y as sucesivamente Otras exclusiones Tambi n quedan ex
39. dad adecuada del aceite para el motor Utilice el cuadro para seleccionar la mejor viscosidad para el intervalo de temperatura exterior previsto eC 104 N 40 86 EM E i 30 68 lu 20 50 ll e 10 32 0 14 E lL o 10 4 2 20 22 LN 30 Por debajo de 4 C 40 F el uso de aceite SAE 30 provocar dificultades de arranque Por encima de 27 C 80 F el uso de aceite 10W30 puede aumentar el consumo de aceite Compruebe el nivel de aceite con mayor frecuencia amp NOTA Todo aceite sint tico que cumpla las AJ especificaciones ILSAC GF 2 con marca de Sm certificaci n API y con s mbolo de servicio API se muestra a la izquierda con SJ CF ENERGY CONSERVING o superior es un aceite aceptable a todas las temperaturas El uso de aceite sint tico no altera los intervalos de cambio de aceite indicados 16 Comprobaci n del nivel de aceite Compruebe el nivel de aceite antes de cada uso o cada 8 horas de funcionamiento como m nimo Rellene si es necesario 1 Coloque el generador sobre una superficie nivelada 2 Quite el tap n de llenado de aceite y limpielo con un trapo 3 Compruebe que el aceite llega hasta el punto de desbordamiento en el orificio de llenado 4 nstale el tap n de llenado de aceite apriete firmemente Adici n de aceite del motor 1 Aseg rese de que la generador est en una superficie
40. dirt or oil Use a vacuum cleaner to pick up loose dirt and debris 15 92ueua ure Maintenance Engine Maintenance A WARNING Unintentional sparking can result in fire or electric shock WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR e Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK e Use approved spark plug tester e DO NOT check for spark with spark plug removed Oil Oil Recommendations We recommend the use of Briggs amp Stratton Warranty Certified oils for best performance Other high quality detergent oils are acceptable if classified for service SF SG SH SJ or higher DO NOT use special additives Outdoor temperatures determine the proper oil viscosity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected OF 104 N 40 6 cS e 30 68 20 50 9 10 32 0 14 10 4 __ _ 20 22 N A Y 230 Below 40 4 the use of SAE 30 will result in hard starting Above 80 F 27 C the use of 10W30 may cause increased oil consumption Check oil level more frequently zw NOTE Synthetic oil meeting ILSAC GF 2 API F certification mark and API service symbol with SJ CF ENERGY CONSERVING
41. eers code J1940 Small Engine Power amp Torque Rating Procedure and rating performance has been obtained and corrected in accordance with SAE J1995 Revision 2002 05 Torque values are derived at 3060 RPM horsepower values are derived at 3600 RPM Actual gross engine power will be lower and is affected by among other things ambient operating conditions and engine to engine variability Given both the wide array of products on which engines are placed and the variety of environmental issues applicable to operating the equipment the gas engine will not develop the rated gross power when used in a given piece of power equipment actual on site or net power This difference is due to a variety of factors including but not limited to accessories air cleaner exhaust charging cooling carburetor fuel pump etc application limitations ambient operating conditions temperature humidity altitude and engine to engine variability Due to manufacturing and capacity limitations Briggs amp Stratton may substitute an engine of higher rated power for this Series engine 24 Briggs amp Stratton Power Products Group LLC 900 N Parkway Jefferson Wisconsin 53549 U S A 800 743 4115 BRIGGSandSTRATTON COM N S Generador Port til de 5550 Vatios Manual del Operario BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A Muchas gracias por comprar este generador Briggs amp Stratton de gran ca
42. eld is driven at about 3 600 rpm by a single cylinder engine NOTICE damage generator and or electrical devices connected to it Don t Overload Generator in the Operation section Every effort has been made to ensure that the information in this manual is both accurate and current However the manufacturer reserves the right to change alter or otherwise improve the generator and this documentation at any time without prior notice The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency and the California Air Resources Board Safety Rules This is the safety alert symbol It is used to alert A you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death The safety alert symbol is used with a signal word DANGER WARNING CAUTION a pictorial and or a safety message to alert you to hazards DANGER indicates a hazard which if not avoided will result in death or serious injury WARNING indicates a hazard which if not avoided could result in death or serious injury CAUTION indicates a hazard which if not avoided might result in minor or moderate injury NOTICE indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warni
43. erador deber ser encendido al menos una vez cada siete d as y deber dejarlo funcionar al menos durante 30 minutos Si no puede hacer esto y debe almacenar la unidad por m s de 30 d as siga las siguientes instrucciones para preparar su unidad para almacenamiento Generador 1 Limpie el generador como est descrito en Limpieza 2 Revise que las ranuras para el aire de enfriamiento y las aperturas del generador se encuentren abiertas y despejadas Almacenamiento para periodos prolongados El combustible puede estar pasado 30 d as despu s de su almacenamiento El combustible pasado provoca la formaci n de residuos cidos y de carbonilla en el circuito de combustible y en los componentes b sicos del carburador Para mantener el combustible en buen estado utilice el estabilizador de combustible FRESH START de Briggs amp Stratton en cualquiera de sus variantes l quido o cartucho concentrado con goteo Si se a ade un estabilizador de combustible conforme a las instrucciones no ser necesario vaciar el motor de combustible Haga funcionar el motor durante dos minutos para que el estabilizador circule por todo el circuito de combustible El motor y el combustible se pueden almacenar hasta 24 meses Si no se ha a adido un estabilizador de combustible a la gasolina deber vaciar completamente el motor utilizando un contenedor homologado Deje funcionar el motor hasta que se agote el combustible Se recomienda utilizar un
44. ervice You can also contact Briggs amp Stratton Customer Service by phone at 800 743 4115 or on the Internet at BRIGGSandSTRATTON COM Generator Model Number L L TJ Revision Serial Number fy jJ Engine Mode Number TTT Type Number a fae Date Purchased LII LL Briggs amp Stratton Power Products Group LLC 900 North Parkway Jefferson 53549 Copyright 2007 Briggs amp Stratton Power Products Group LLC All rights reserved No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs amp Stratton Power Products Group LLC 2 BRIGGSandSTRATTON COM Table of Contents Operator Safety 4 DOS ss gas ive a Goa eA n 4 Safety ad e Race beoe SO 4 Assembly 7 Unpack 7 Install Wheel a 8 A A 8 System 9 Connecting to a Building s Electrical SysteM 9 Generator Location 9 Features and 0 10 Cord Sets and Receptacles 11 Operation
45. et spark plug gap to recommended gap if necessary see Specifications Lp AC AN G N Y M 4 Replace spark plug if electrodes are pitted burned or porcelain is cracked Use the recommended replacement spark plug See Specifications 5 Install spark plug and tighten firmly Service Spark Arrester The engine exhaust muffler has a spark arrester screen Inspect and clean the screen every 100 hours of operation or once each year whichever comes first If you use your generator on any forest covered brush covered or grass covered unimproved land it must have a spark arrester The spark arrester must be maintained in good condition by the owner operator If the engine has been running the muffler will be very hot Allow the muffler to cool before servicing the spark arrester D Contact with muffler area can result in serious W burns KNS structures or damage fuel tank causing a fire 4 Exhaust heat gases can ignite combustibles Y DO NOT touch hot parts and AVOID hot exhaust gases e Allow equipment to cool before touching e Keep at least 5 feet 1 5 m of clearance on all sides of generator including overhead Code of Federal Regulation CFR Title 36 Parks Forests and Public Property require equipment powered by an internal combustion engine to have a spark arrester maintained in effective working order complying to USDA Forest service standard 5100 1C or later revision In the State
46. etera 1500 1500 2500 Estufa el ctrica Elemento simple Plancha de cocina Habitaci n familiar Reproductor de DVD CD 100 CR 100 450 Televisi n en color 27 500 lt Receptor est reo Ordenador personal con monitor de 17 800 Sistema de seguridad Radio reloj AM FM Dispositivo de apertura de garage 1 2 T U Calentador de agua el ctrico 150 litros aprox 40 galones Taller Luz hal gena de cuarzo para trabajar Rociador sin aire 1 3 HP Sierra sable Taladro el ctrico 1 2 HP Sierra Radial 10 Sierra inglete 10 Cepilladora de mesa 6 Sierra de mesa Sierra de brazo radial Compresor de aire 1 1 2 HP o La potencia que aparece en la lista es aproximada Compruebe la herramienta o aparato el ctrico para obtener la potencia real BRIGGSandSTRATTON COM Mantenimiento Plan de mantenimiento Siga los intervalos de horas o de calendario los que sucedan antes Si opera en condiciones adversas se aladas m s abajo es necesario un mantenimiento m s frecuente Primeras Cinco 5 Horas e Cambie el aceite del motor Cada 8 horas o diario e Limpie los residuos e Compruebe el nivel de aceite Cada 25 horas o una vez al a o e Mantenimiento del filtro de aire Cada 50 horas o una vez al a o e Cambie el aceite del motor Cada 100 horas o una vez al a o e Servicio a la buj a e Servicio al sistema de la buj a e Limpie el sistema de refriger
47. eva la palanca estranguladora hasta la posici n Choke Estrangular II 4 Sit e el interruptor balanc n del motor en la posici n Ne S5 Pa 5 Hale la manija de retroceso en forma suave hasta que sienta resistencia Luego para arrancar el motor hacer tracci n en forma r pida una sola vez e Siel motor arranca contin e con el paso 7 e Siel motor no arranca proceda con el paso ADVERTENCIA El retroceso repliegue r pido del cable del arrancador puede producir lesiones El retroceso ig impedir que el usuario suelte el cable a tiempo y tirar de su mano y brazo hacia el motor Como resultado podr an producirse fracturas contusiones o esguinces e Cuando arranque el motor tire lentamente del cable hasta sentir una resistencia y a continuaci n tire r pidamente de l para evitar su retroceso e NUNCA arranque o pare el motor cuando haya aparatos el ctricos conectados y en funcionamiento 12 6 Mueva la palanca de choque hasta la posici n Half media y accione dos veces la manija de retroceso e Siel motor no arranca repita los pasos desde 5 hasta 7 Coloque la palanca de retroceso en la posici n de 1 Si el motor vacila mueva la palanca de retroceso hasta la posici n media Half hasta que el motor marche suavemente y luego col quelo en la posici n de marcha 141 IMPORTANTE Si el motor se desborda coloque la palanca estranguladora e
48. ezing from top of e ring to bottom of axle Repeat steps 4 and 5 to secure second wheel lip generator so that engine side is down Attach the vibration mounts E to the support leg F with 1 4 20 x 1 capscrews G and 1 4 20 lock nuts H Remove the existing locknut from the left unit vibration mount with 13mm wrench Use the same locknut to attach the support leg Attach the other side of the support leg with a M8 x 20 mm capscrew J and M8 lock nut K Center handle L on generator frame as shown and attach with M8 45 mm capscrews M and 8 lock nuts N Return generator to normal operating position resting on wheels and support leg quiassy Assembly Add Engine Oil Ah WARNING 1 Place generator on a flat level surface 2 Clean area around oil fill and remove yellow oil fill cap Fuel and its vapors are extremely flammable and NOTE See the section Oil to review oil recommendations explosive Verify provided oil bottle is correct viscosity for current Fire or explosion can cause severe burns or ambient temperature death 3 Using oil funnel optional slowly pour contents of provided oil bottle into oil fill opening WHEN ADDING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion If fuel spills wait until it evaporates be
49. fore starting engine Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke NOTICE Improper treatment of generator can damage it and shorten its life e DO NOT attempt to crank or start the engine before it has been properly serviced with the recommended oil This may result in an engine failure 4 Replace oil fill cap and fully tighten Add Fuel 1 Clean area around fuel fill cap remove cap Fuel must meet these requirements 2 Slowly add unleaded gasoline A to fuel tank B Be careful not to overfill Allow about 1 5 4 cm of tank e Clean fresh unleaded gasoline space C for fuel expansion e minimum of 87 octane 87 AKI 91 RON High altitude use see High Altitude e Gasoline with up to 10 ethanol gasohol or up to 15 MTBE methyl tertiary butyl ether is acceptable NOTICE Avoid generator damage Failure to follow Operator s Manual for fuel 3 Install fuel cap and let any spilled fuel evaporate before starting engine recommendations voids warranty e DO NOT use unapproved gasoline such as E85 e DO NOT mix oil in gasoline High Altitude e DO NOT modify engine to run on alternate fuels At altitudes over 5 000 feet 1524 meters a minimum 85 octane 85 AKI 89 RON gasoline is acceptable To remain emissions compliant high altitude adjustment is required Operation without this adjustment will cause decreased per
50. formance increased fuel consumption and To protect the fuel system from gum formation mix in a fuel stabilizer when adding fuel See Storage All fuel is not the same If you experience starting or performance problems after using fuel switch to a different fuel provider or change increased emissions See an authorized dealer for high brands This engine Is certified to operate on gasoline The altitude adjustment information Operation of the engine at emission control system for this engine is EM Engine altitudes below 2 500 feet 762 meters with the high altitude Modifications kit is not recommended 8 BRIGGSandSTRATTON COM System Ground The generator has a system ground that connects the generator frame components to the ground terminals on the output receptacles The system ground is connected to the AC neutral wire the neutral is bonded to the generator frame Special Requirements There may be Federal or State Occupational Safety and Health Administration OSHA regulations local codes or ordinances that apply to the intended use of the generator Please consult a qualified electrician electrical inspector or the local agency having jurisdiction e n some areas generators are required to be registered with local utility companies e f the generator is used at a construction site there may be additional regulations which must be observed Connecting to a Building s Electrical System Connections for st
51. g and surge starting watts for the items you will power at the same time Follow these simple steps 1 Select the items you will power at the same time 2 Total the rated running watts of these items This is the amount of power your generator must produce to keep your items running See Wattage Reference Guide 3 Estimate how many surge starting watts you will need Surge wattage is the short burst of power needed to start electric motor driven tools or appliances such as a circular saw or refrigerator Because not all motors start at the same time total surge watts can be estimated by adding only the item s with the highest additional surge watts to the total rated watts from step 2 Example Rated Running Watts Additional Surge Tool or Appliance Starting Watts Window Air 1800 Conditioner Refrigerator 800 1600 Deep Freezer 500 Television 500 Light 75 Watts 3075 Total 1800 Highest Running Watts Surge Watts Total Rated Running Watts 3075 Highest Additional Surge Watts 1800 Total Generator Output Required 4875 Power Management To prolong the life of your generator and attached devices it is important to take care when adding electrical loads to your generator There should be nothing connected to the generator outlets before starting its engine The correct and safe way to manage generator power is to sequentially add loads as follows 1 With nothing connected to the generator star
52. g System e Cold start enrichment system soft choke e Carburetor and internal parts e Fuel Pump e Fuel line fuel line fittings clamps e Fuel tank cap and tether e Carbon canister b Air Induction System e Air cleaner e Intake manifold e Purge and vent line c Ignition System e Spark plug s e Magneto ignition system d Catalyst System e Catalytic converter e Exhaust manifold e Air injection system or pulse valve e Miscellaneous Items Used in Above Systems e Vacuum temperature position time sensitive valves and switches e Connectors and assemblies 21 2 Length of Coverage B amp S warrants to the initial owner and each subsequent purchaser that the Warranted Parts shall be free from defects in materials and workmanship which caused the failure of the Warranted Parts for a period of two years from the date the engine is delivered to a retail purchaser 3 No Charge Repair or replacement of any Warranted Part will be performed at no charge to the owner including diagnostic labor which leads to the determination that a Warranted Part is defective if the diagnostic work is performed at an Authorized B amp S Service Dealer For emissions warranty service contact your nearest Authorized B amp S Service Dealer as listed in the Yellow Pages under Engines Gasoline Gasoline Engines Lawn Mowers or similar category 4 Claims and Coverage Exclusions Warranty claims shall be filed in accordance with the prov
53. giratorio del generador se mueve a unas 3 600 rpm con un motor de un uno cilindro Se ha realizado el m ximo esfuerzo para reunir en este documento la informaci n m s precisa y actualizada No obstante nos reservamos el derecho de modificar alterar o mejorar de cualquier otra forma el generador en cualquier momento y sin previo aviso El Sistema de Control de Emisiones para este generador est garantizado para juegos est ndares por la Agencia de Protecci n Ambiental y el Consejo de recursos de aire de California El sobrepasar la capacidad del amperaje y vataje del generador puede da ar al generador y los aparatos el ctricos conectados al mismo e Vea No sobrecargue generador Reglas de seguridad ste es el s mbolo de alerta de seguridad Sirve A para advertir al usuario de un posible riesgo para su integridad fisica Siga todos los mensajes de seguridad que figuren despu s de este simbolo para evitar lesiones o incluso la muerte El s mbolo de alerta de seguridad se utiliza con una palabra de se alizaci n PELIGRO PRECAUCION ADVERTENCIA una imagen y o un mensaje de seguridad para advertir al usuario de un riesgo PELIGRO indica un riesgo que de no evitarse provocar la muerte o lesiones de gravedad ADVERTENCIA indica un riesgo que de no evitarse puede provocar la muerte o lesiones de gravedad PRECAUCION indica un riesgo que de no evitarse puede provocar lesiones moderadas Cuando se utiliza
54. go o el golpe el ctrico e NUNCA arranque el motor sin la buj as instalada Otras sugerencias para el almacenamiento 1 NO guarde combustible de una temporada a otra a menos que lo haya tratado como se indica en la secci n Almacenamiento Para Periodos Prolongados 2 Reemplace la caneca de gasolina si comienza a oxidarse El xido y o la suciedad en la gasolina le causar problemas 3 su unidad con una cubierta de protecci n adecuada que no retenga humedad Ah ADVERTENCIA A KY Las cubiertas para almacenamiento pueden ser linflamables e NO coloque una cubierta encima de un generador caliente e Deje que la unidad se enfr e lo suficientemente antes de que le coloque la cubierta 4 Almacene la unidad en un rea limpia y seca T e F CD 3 CD ea e Problemas Resoluci n de problemas Problemo El motor est funcionando pero no existe salida de AC disponsible El motor funciona bien sin carga pero funciona mal cuando se le contectan cargas El motor no se enciende o se enciende y funciona mal El motor se apaga en pleno funcionamiento Causa El interruptor autom tico de circuito est abierto Conexi n mal o defectuosa del juego de cables El dispositivo conectado est da ado Aver a en el generador Corto circuito en una de las cargas conectadas El generador est sobrecarga Velocidad del motor es muy len
55. ia En otros estados puede haber leyes similares en vigor BRIGGSandSTRATTON COM Conexi n de cargas el ctricas Parada del motor 1 Deje que el motor se estabilice y se caliente por dos 1 Desconecte todas las cargas el ctricas de los minutos despu s del arranque tomacorrientes del panel del generador NUNCA de 2 Ench felo y encienda la carga el ctrica deseada arranque o detenga el motor con todos los dispositivos 120 y o 240 V CA monof sico 60 Hz el ctricos conectados y encendidos 2 Deje que el motor funcione sin cargas por algunos NOTA minutos para estabilizar las temperaturas internas del e NO conectar cargas de 240 V en las tomas el ctricas motor y el generador dobles 3 Sit e el interruptor balanc n en la posici n Off e NO conectar cargas trif sicas al generador ADVERTENCIA e NO conectar cargas de 50 Hz al generador e NO SOBRECARGAR EL GENERADOR V ase No sobrecargar el generador El sobrepasar la capacidad del amperaje y vataje del SIEUT el ctricos conectados al mismo Vea Vo sobrecargue generador El motor podr a petardear incendiarse o da arse e NO coloque la palanca estranguladora en la posici n Choke II para parar el motor Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el ctricas Conecte las cargas el ctricas en la posici n de apagado OFF luego encienda ON para su operaci n Apague OFF las cargas el ctricas y
56. iento del motor pero B amp S no puede denegar la garant a bas ndose nicamente en la falta de facturas o en la imposibilidad por parte del propietario de asegurar la correcta realizaci n de todas las operaciones de mantenimiento Como propietario del peque o motor para m quinas de servicio debe ser consciente de que B amp S puede denegar la cobertura de la garant a si el motor o uno de sus componentes falla debido a un uso indebido o negligente un mantenimiento inadecuado o modificaciones no autorizadas Usted es responsable de presentar su peque o motor para m quinas de servicio a un distribuidor autorizado de servicio B amp S en el momento en que surja un problema Las reparaciones cubiertas por la garant a se llevar n a cabo en un plazo razonable no superior a 30 d as en ning n caso En caso de preguntas sobre los derechos y responsabilidades relativos a la garant a consulte con un representante de servicio de B amp S llamando al 1 414 259 5262 La garant a de emisiones es una garant a contra defectos Los defectos se juzgan en funci n del rendimiento normal del motor La garant a no depender de ninguna prueba de emisiones en funcionamiento Disposiciones de la garant a contra defectos del sistema de control de emisiones de Briggs amp Stratton continuaci n se detallan las disposiciones concretas relativas a la Cobertura de la garant a contra defectos del sistema de control de emisiones Se a aden a l
57. isions of the B amp S Engine Warranty Policy Warranty coverage shall be excluded for failures of Warranted Parts which are not original B amp S parts or because of abuse neglect or improper maintenance as set forth in the B amp S Engine Warranty Policy B amp S is not liable to cover failures of Warranted Parts caused by the use of add on non original or modified parts 5 Maintenance Any Warranted Part which is not scheduled for replacement as required maintenance or which is scheduled only for regular inspection to the effect of repair or replace as necessary shall be warranted as to defects for the warranty period Any Warranted Part which is scheduled for replacement as required maintenance shall be warranted as to defects only for the period of time up to the first scheduled replacement for that part Any replacement part that is equivalent in performance and durability may be used in the performance of any maintenance or repairs The owner is responsible for the performance of all required maintenance as defined in the B amp S Operator s Manual 6 Consequential Coverage Coverage hereunder shall extend to the failure of any engine components caused by the failure of any Warranted Part still under warranty 22 Emission Information Engines that are certified to meet the California Air Resources Board CARB Tier 2 Emission Standards must display information regarding the Emissions Durability Period and Air Index The engi
58. izada que deba sustituirse como parte del mantenimiento obligatorio quedar n cubiertos nicamente durante el per odo comprendido entre la compra y la primera sustituci n indicada en el plan de mantenimiento En las operaciones de mantenimiento y reparaci n se podr utilizar cualquier pieza de recambio de rendimiento y durabilidad equivalentes El propietario es responsable del cumplimiento de todas las operaciones de mantenimiento obligatorio que se definen en el manual del operario de B amp S Cobertura de dafios derivados La cobertura se ampliar a los fallos de cualquier componente del motor derivados del fallo de cualquier pieza garantizada y cubierta por la garant a Informaci n sobre emisiones Los motores con certificaci n de cumplimiento de la normativa sobre emisiones de nivel 2 del California Air Resources Board CARB deben mostrar informaci n sobre el per odo de durabilidad de las emisiones y el ndice de aire El fabricante del motor ofrece esta informaci n al consumidor mediante etiquetas de emisiones La etiqueta de emisiones del motor contiene la informaci n de certificaci n El Per odo de Durabilidad de las Emisiones indica el n mero de horas durante las cuales el motor puede funcionar cumpliendo las normas sobre emisiones siempre que se realicen las operaciones de mantenimiento que se detallan en las instrucciones de uso y mantenimiento Se utilizan las siguientes categor as Moderado El motor es
59. jury and or property damage CAUTION Excessively high operating speeds increase risk of injury Contact with muffler area can result in serious and damage to generator burns ul am uem Excessively low speeds impose a heavy load Y xhaust heat gases can ignite combustibles y structures or ade causing a fire e DO NOT tamper with governed speed Generator supplies correct rated frequency and voltage when running at governed speed DO NOT touch hot parts and AVOID hot exhaust gases DO NOT modify generator in any way Allow equipment to cool before touching Keep at least 5 feet 1 5 m of clearance on all sides of NOTICE generator including overhead NOTICE Code of Federal Regulation CFR Title 36 Parks Forests and Exceeding generators wattage amperage capacity can Public Property require equipment powered by an internal damage generator and or electrical devices connected to it combustion engine to have a spark arrester maintained in e DO NOT exceed the generator s wattage amperage capacity See effective working order complying to USDA Forest service Don t Overload Generator in the Operation section standard 5100 1C or later revision In the State of California a a spark arrester is required under section 4442 of the California Mw 0 0 0 Public resources code Other states may have similar laws e e Connect electrical loads in OFF position then turn ON for
60. l devices Some devices however may not require this type of extension cord Check the operator s manuals of those devices for the manufacturer s recommendations Keep extension cords as short as possible to minimize voltage drop Ah WARNING Overloaded electrical cords can overheat arc land burn resulting in death bodily injury and or property damage e ONLY use cords rated for your loads e Follow all safeties on electrical cords 120 240 Volt AC 30 Amp Locking Receptacle Use a NEMA L14 30 plug with this receptacle Connect a 4 wire cord set rated for 250 Volt AC loads at 30 Amps or greater You can use the same 4 wire cord if you plan to run a 120 Volt load Ls 4 Wire Cord Set W Neutral 120V NEMA L14 30 Y Hot X Hot Ground Green This receptacle powers 120 240 Volt AC 60 Hz single phase loads requiring up to 5 550 watts of power 5 55 kW at 23 1 Amps for 240 Volts or two independent 120 Volt loads at 23 1 Amps each The outlet is protected by a push to reset circuit breaker NOTICE Receptacles may be marked with rating value greater than generator output capacity e NEVER attempt to power a device requiring more amperage than generator or receptacle can supply DO NOT overload the generator See Don t Overload Generator 120 Volt AC 20 Amp Duplex Receptacles Each duplex receptacle is protected against overload by a push to reset circuit breaker Use each re
61. lidad Nos alegra que haya depositado su confianza en la marca Briggs amp Stratton Siempre que sea utilizado de acuerdo con las instrucciones de este manual su generador Briggs amp Stratton le proporcionar muchos a os de buen funcionamiento Este manual contiene informaci n sobre seguridad para hacerle consciente de los riesgos asociados a los generadores y mostrarle c mo evitarlos Este generador se ha dise ado exclusivamente para suministrar energ a el ctrica a cargas compatibles de iluminaci n electrodom sticos herramientas y motores No debe utilizarse para ning n otro fin Es importante leer detenidamente y comprender estas instrucciones antes de poner en marcha o utilizar el equipo Conserve este manual para futuras consultas Este generador requiere montaje final antes de ser usado Consulte la secci n Montaje de este manual donde encontrar instrucciones para el montaje final Siga las instrucciones al pie de la letra D nde encontrarnos Usted no tendr que ir muy lejos para encontrar el servicio t cnico de Briggs amp Stratton para su generador Consulte las P ginas Amarillas Hay m s de 30 000 proveedores de Briggs 4 Stratton autorizados en todo el mundo proporcionando un servicio de calidad Tambi n puede ponerse en contacto con Atenci n al Cliente de Briggs amp Stratton llamando al 800 743 4115 o por Internet en BRIGGSandSTRATTON COM Generador Revisi n EN Motor Fecha de compra EN EN B
62. llenado del combustible retire la tapa 2 A ada lentamente gasolina sin plomo A al tanque de combustible B Tenga cuidado de que el nivel de combustible no rebase el l mite C Esto permite dejar el espacio adecuado para que el combustible se expanda como se muestra 3 Instale la tapa del tanque de combustible y la espera para alg n combustible rociado para evaporar Gran altitud En altitudes superiores a 1 524 metros 5 000 pies se deber utilizar gasolina con un m nimo de 85 octanos 85 AKI 89 RON Para seguir cumpliendo la normativa sobre emisiones es necesario ajustar la unidad para su uso a gran altitud De no realizarse este ajuste el rendimiento se reducir y el consumo de combustible y las emisiones aumentar n Para obtener m s informaci n sobre el ajuste para gran altitud consulte con un distribuidor cualificado de Briggs amp Stratton No se recomienda utilizar el motor a altitudes inferiores a 762 metros 2 500 pies con el juego de gran altitud BRIGGSandSTRATTON COM Tierra del sistema El generador dispone de una conexi n a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA La tierra del sistema est conectada al cable de CA neutro que a su vez est conectado al bastidor del generador el neutro est conectado al bastidor del generador Requisitos especiales Es posible que haya normas u ordenanzas locales
63. lso have other rights which vary from state to state or country to country WARRANTY PERIOD Consumer Use 2 years Commercial Use 1 year Second year parts only The warranty period begins on the date of purchase by the first retail end user and continues for the period of time stated above Consumer Use means personal residential household use by a retail consumer Commercial Use means all other uses including use for commercial income producing or rental purposes Once equipment has experienced commercial use it shall thereafter be considered as commercial use for purposes of this warranty NO WARRANTY REGISTRATION 15 NECESSARY TO OBTAIN WARRANTY ON BRIGGS amp STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE 15 REQUESTED THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD ABOUT YOUR WARRANTY We welcome warranty repair and apologize to you for being inconvenienced Any Authorized Service Dealer may perform warranty repairs Most warranty repairs are handled routinely but sometimes requests for warranty service may not be appropriate For example warranty service would not apply if equipment damage occurred because of misuse lack of routine maintenance shipping handling warehousing or improper installation Similarly the warranty is void if the manufacturing date or the serial number on the portable generato
64. n la posici n 1 1 e intente arrancarlo hasta conseguirlo NOTA Si el motor arranca despu s de tirar tres veces del arrancador pero no sigue funcionando o si la unidad se para en funcionamiento aseg rese de que la unidad est en una superficie plana y compruebe que el nivel de aceite del cigue al es correcto La unidad puede equiparse con un dispositivo de protecci n de bajo nivel de aceite En caso afirmativo el nivel del aceite debe ser adecuado para que el motor arranque ADVERTENCIA El contacto con la zona del silenciador puede of producir quemaduras graves t 0 y Los gases y el calor de escape pueden inflamar 2 los materiales combustibles y las estructuras o d da ar el dep sito de combustible y provocar un incendio e NO toque las superficies calientes y EVITE los gases del escape a alta temperatura e Permita que el equipo se enfr e antes de tocarlo e Deje un espacio m nimo de 1 5 m 5 pies alrededor del generador incluida la parte superior e El C digo de Normativa Federal CFR T tulo 36 Parques Bosques y Propiedad P blica obliga a instalar una pantalla apagachispas en los equipos con motor de combusti n interno y a mantenerla en buenas condiciones de funcionamiento conforme a la norma 5100 1C o posterior del Servicio Forestal de la USDA En el Estado de California la ley exige el uso de una pantalla apagachispas Secci n 4442 del C digo de Recursos P blicos de Californ
65. ne is low emission It is equipped with a non adjustable idle mixture valve Top speed has been set at the factory If adjustment is required see an authorized service dealer A CAUTION Excessively high operating speeds increase risk of injury and damage to generator Excessively low speeds impose a heavy load DO NOT tamper with governed speed Generator supplies correct rated frequency and voltage when running at governed speed DO NOT modify generator in any way BRIGGSandSTRATTON COM Storage The generator should be started at least once every seven days and allowed to run at least 30 minutes If this cannot be done and you must store the unit for more than 30 days use the following guidelines to prepare it for storage Generator Storage e Clean the generator as outlined in Cleaning e Check that cooling air slots and openings on generator are open and unobstructed Long Term Storage Instructions Fuel can become stale when stored over 30 days Stale fuel causes acid and gum deposits to form in the fuel system or on essential carburetor parts To keep fuel fresh use Briggs amp Stratton FRESH START fuel stabilizer available as a liquid additive or a drip concentrate cartridge There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions Run the engine for 2 minutes to circulate the stabilizer throughout the fuel system The engine and fuel can then be stored up to
66. ne manufacturer makes this information available to the consumer on emission labels The engine emission label will indicate certification information The Emissions Durability Period describes the number of hours of actual running time for which the engine is certified to be emissions compliant assuming proper maintenance in accordance with the Operating amp Maintenance Instructions The following categories are used Moderate Engine is certified to be emission compliant for 125 hours of actual engine running time Intermediate Engine is certified to be emission compliant for 250 hours of actual engine running time Extended Engine is certified to be emission compliant for 500 hours of actual engine running time For example a typical walk behind lawn mower is used 20 to 25 hours per year Therefore the Emissions Durability Period of an engine with an intermediate rating would equate to 10 to 12 years Certain engines will be certified to meet the United States Environmental Protection Agency USEPA Phase 2 emission standards For phase 2 certified engines the Emissions Compliance Period referred to on the Emissions Compliance label indicates the number of operating hours for which the engine has been shown to meet Federal emission requirements For engines less than 225 cc displacement Category C 125 hours Category B 250 hours Category A 500 hours For engines of 225 cc or more displacement Category C 250 h
67. ngs in this manual and the tags and decals affixed to the unit are therefore not all inclusive If you use a procedure work method or operating technique that the manufacturer does not specifically recommend you must satisfy yourself that it is safe for you and others You must also make sure that the procedure work method or operating technique that you choose does not render the generator unsafe Hazard Symbols and Meanings Ww z7 9 F Hot Surface G Flying Objects H Moving Parts J Read Manual A Explosion B Fire C Electric Shock D Toxic Fumes E Kickback DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents Ah WARNING Running engine gives off carbon monoxide an odorless colorless poison gas Breathing carbon monoxide can cause headache fatigue dizziness vomiting confusion seizures nausea fainting or death Operate generator ONLY outdoors Install a battery operated carbon monoxide alarm near the bedrooms Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings DO NOT start or run engine indoors or in an enclosed area even if windows and doors are open including the generato
68. ntenimiento en la secci n Mantenimiento Es igualmente importante que no se acumulen residuos en la parte superior del motor ni en la pantalla giratoria Consulte la secci n Limpieza Comprobaci n de holgura de la v lvula Si comprueba y ajusta la holgura de la v lvula regularmente el funcionamiento del motor mejorar y tendr una mayor vida til Este procedimiento no puede llevarse a cabo sin desmontar parcialmente el motor y sin usar herramientas especiales Por esta raz n le recomendamos que un distribuidor autorizado compruebe y ajuste la holgura de la v lvula siguiendo los intervalos recomendados consulte la secci n Plan de Mantenimiento en la secci n Mantenimiento Ajuste del carburador El carburador de este motor es de baja emisi n Est equipado con una v lvula de mezcla de ralent no ajustable y en algunos casos con ralent regulado Los niveles de ralent regulado y velocidad m xima se ajustan en la f brica Si es necesario modificarlos acuda a un distribuidor autorizado PRECAUCI N Las velocidades de operaci n en exceso aumentan los riesgos de heridas y da os al generador Las velocidades bajan en exceso imponen una carga muy pesada e NO cambie ninguna velocidad determinada El generador suministra una frecuencia y un voltaje calificado cuando funciona a una velocidad determinada e NO modifique al generador en ninguna forma BRIGGSandSTRATTON COM Almacenamiento El gen
69. ong Term Storage Instructions 2 Replace fuel container if it starts to rust Rust and or dirt in fuel can cause problems if it s used with this unit 3 Cover unit with a suitable protective cover that does not retain moisture 4 d 4 Storage covers can be flammable e DO NOT place a storage cover over a hot generator e Let equipment cool for a sufficient time before placing the cover on the equipment 4 Store generator in clean dry area 19 e e 2 S o ES e 2 Troubleshooting Problem Cause Correction One of the circuit breakers is open 1 Reset circuit breaker EN Fault in generator 2 Contact authorized service facility Engine is running but no AC output is available Poor connection or defective cord set 3 Check and repair Connected device is bad 4 Connect another device that is in good condition Short circuit in a connected load 1 Disconnect shorted electrical load Engine runs good at no load but 2 Engine speed is too slow 2 Contact authorized service facility bogs down when loads are Generator is overloaded 3 See Don t Overload Generator in connected Operation section Shorted generator circuit 4 Contact authorized service facility Rocker switch set to Off 1 Set switch to On Fuel Valve is in Off position 2 Turn fuel valve to Open position Dirty air cleaner 3 Clean or replace air cleaner O
70. os que pueden variar de un pa s o estado a otro PER ODO DE GARANT A Uso del consumidor 2 a os Uso comercial 1 ano Segundo a o despide s lo El per odo de garant a comienza la fecha de compra del primer usuario final y se prolonga durante el tiempo especificado Uso del consumidor significa uso dom stico personal por parte de un consumidor final Uso comercial significa cualquier otro uso incluidos los usos con fines comerciales de generaci n de ingresos o alquiler Una vez que el equipo se haya usado con fines comerciales se considerar como equipo de uso comercial a efectos de esta garant a NO ES NECESARIO REGISTRAR LA GARANT A PARA OBTENER SERVICIO DE BRIGGS amp STRATTON PRODUCTS GUARDE SU RECIBO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZAR LA FECHA DE FABRICACI N DEL PRODUCTO PARA DETERMINAR EL PER ODO DE GARANT A ACERCA DE LA EQUIPO GARANT A Esperamos que disfrute de nuestra garant a y le pedimos disculpas por las molestias causadas Cualquier distribuidor de servicio autorizado puede llevar a cabo reparaciones en garant a La mayor a de las reparaciones en garant a se gestionan normalmente pero algunas veces la solicitud de servicio en garant a puede no ser procedente Por ejemplo la garant a no ser v lida si el equipo presenta dafios debidos al mal uso la falta de mantenimiento el transporte la manipulaci n el almacenamiento o la instalaci n inade
71. ours Category B 500 hours Category A 1000 hours BRIGGSandSTRATTON COM BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC PORTABLE GENERATOR OWNER WARRANTY POLICY Effective February 1 2006 replaces all undated Warranties and all Warranties dated before February 1 2006 LIMITED WARRANTY Briggs amp Stratton Power Products Group LLC will repair or replace free of charge any part s of the portable generator that is defective in material or workmanship or both Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser This warranty is effective for the time periods and subject to the conditions stated below For warranty service find the nearest Authorized Service Dealer in our dealer locator map at BRIGGSandSTRATTON COM THERE IS NO OTHER EXPRESS WARRANTY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM PURCHASE OR TO THE EXTENT PERMITTED BY LAW ANY AND ALL IMPLIED WARRANTIES ARE EXCLUDED LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW Some states or countries do not allow limitations on how long an implied warranty lasts and some states or countries do not allow the exclusion or limitation of incidental or consequential damages so the above limitation and exclusion may not apply to you This warranty gives you specific legal rights and you may a
72. perior El C digo de Normativa Federal CFR T tulo 36 Parques Bosques y Propiedad P blica obliga a instalar una pantalla apagachispas en los equipos con motor de combusti n interno y a mantenerla en buenas condiciones de funcionamiento conforme a la norma 5100 1C o posterior del Servicio Forestal de la USDA En el Estado de California la ley exige el uso de una pantalla apagachispas Secci n 4442 del C digo de Recursos P blicos de California En otros estados puede haber leyes similares en vigor Limpie e inspeccione el apagachispas de la siguiente manera 1 Para retirar la protecci n del silenciador A de silenciador B retire los cuatro tornillos que conectan la protecci n a la m nsula del silenciador 2 Retire los cuatro tornillos que sostienen la pantalla apagachispas 6 3 Inspeccione la pantalla y reempl cela si est rota perforada o da ada NO use pantallas defectuosas Si la pantalla no est da ada limpiela con un disolvente comercial 4 Vuelva a instalar la pantalla y la protecci n del silenciador 18 Sistema de refrigeraci n de aire Con el tiempo se pueden acumular residuos en las aletas de refrigeraci n del cilindro y pasar inadvertidos mientras no se desmonte parcialmente el motor Recomendamos que encargue la limpieza del sistema de refrigeraci n D a un distribuidor autorizado de Briggs amp Stratton siguiendo los intervalos recomendados consulte la secci n Plan de Ma
73. r compartment of a recreational vehicle RV BRIGGSandSTRATTON COM Ah WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Generator produces hazardous voltage Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy When using generator for backup power notify utility company Use approved transfer equipment to isolate generator from electric utility Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain or wet weather DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator Starter cord kickback rapid retraction can result in bodily injury Kickback will pull hand and arm toward engine faster than you can let go Broken bones fractures bruises or sprains could result e When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback e NEVER start or stop engine with electrical devices plugged in and turned on
74. r da os El silenciador del escape del motor posee una pantalla apagachispas Inspeccione y limpie la pantalla cada mbie el filtr ir 29 hor funcionamient f s 100 horas de operaci n o una vez al a o lo que suceda una vez al a o lo que suceda antes Haga cambios m s primero frecuentes si trabaja en zonas sucias o donde hay polvo El generador tendr que tener un apagachispas si lo usa en Para dar servicio al filtro de aire siga los pasos que se terrenos no tratados cubiertos de monte maleza o pasto El detallan a continuaci n apagachispas deber ser mantenido en buenas condiciones 1 Afloje los tornillos D y quite aire la cubierta m s por parte del propietario operador limpia E Si el motor ha estado funcionando el silenciador estar bastante caliente Deje que el silenciador se enfr e para poder darle servicio al apagachispas Espa ol e a n ADVERTENCIA El contacto con la zona del silenciador puede producir quemaduras graves Los gases y el calor de escape pueden inflamar t los materiales combustibles y las estructuras o y da ar el dep sito de combustible y provocar un incendio NO toque las superficies calientes y EVITE los gases del escape a alta temperatura Permita que el equipo se enfr e antes de tocarlo Deje un espacio m nimo de 1 5 m 5 pies alrededor del generador incluida la parte su
75. r disminuye el ruido del motor y est equipado con una pantalla apagachispas F Etiqueta de Datos Proporciona el modelo revisi n y el n mero de serie de generador Tenga por favor estos prontamente disponible cu ndo llamar para la ayuda 10 MMM G Identificaci n del Motor Indica el modelo tipo y c digo del motor Tenga por favor estos prontamente disponible cu ndo llamar para la ayuda H Depurador de Aire Filtra el aire de entrada a medida que penetra en el motor J Palanca Estranguladora Usada cuando se est dando arranque a un motor fr o K Tanque del Combustible El tanque tiene una capacidad de 26 5 L 7 galones americanos de gasolina sin contenido de plomo No mostrado Culatazo el Principio Us para comenzar motor Interruptor Balanc n del Motor Deber estar en la posici n On En para darle arranque al motor Col quelo en la posici n Off Apagado para detener un motor en funcionamiento Tapa del Dep sito del Aceite Llene el motor con aceite aqu Tap n de Vaciado de Aceite Permite vaciar el aceite del motor V lvula de Combustible Permite abrir y cerrar la alimentaci n de combustible al motor BRIGGSandSTRATTON COM Juegos de cordones y enchufes conectores Utilice exclusivamente cables prolongadores de alta calidad bien aislados y con conexi n a tierra para la toma doble de 120
76. r has been removed or the equipment has been altered or modified During the warranty period the Authorized Service Dealer at its option will repair or replace any part that upon examination is found to be defective under normal use and service This warranty will not cover the following repairs and equipment Normal Wear Outdoor Power Equipment like all mechanical devices needs periodic parts and service to perform well This warranty does not cover repair when normal use has exhausted the life of a part or the equipment Installation and Maintenance This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or alteration and modification misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in our judgment to adversely affect its performance and reliability This warranty also does not cover normal maintenance such as air filters adjustments fuel system cleaning and obstruction due to chemical dirt carbon lime and so forth Other Exclusions This warranty excludes wear items such as o rings filters etc or malfunctions resulting from accidents abuse modifications alterations or improper servicing or freezing or chemical deterioration Accessory parts such as starting batteries generator adapter cord sets and storage covers are excluded from the product warranty This warranty excludes used reconditioned and demons
77. r to Run position 1 1 If engine falters move choke lever to Half choke position until engine runs smoothly and then to Run position I41 IMPORTANT If engine floods place choke lever in Run position 1 1 and crank until engine starts NOTE If engine starts after 3 pulls but fails to run or if unit shuts down during operation make sure unit is on a level surface and check for proper oil level in crankcase This unit may be equipped with a low oil protection device If so oil must be at proper level for engine to start j Contact with muffler area can result in serious M burns 00 4 Exhaust heat gases can ignite combustibles structures damage fuel tank causing fire e DO NOT touch hot parts and AVOID hot exhaust gases e Allow equipment to cool before touching e Keep at least 5 feet 1 5 m of clearance on all sides of generator including overhead Code of Federal Regulation CFR Title 36 Parks Forests and Public Property require equipment powered by an internal combustion engine to have a spark arrester maintained in effective working order complying to USDA Forest service standard 5100 1C or later revision In the State of California a spark arrester is required under section 4442 of the California Public resources code Other states may have similar laws BRIGGSandSTRATTON COM Connecting Electrical Loads 1 Let engine stabilize and warm up for a few minutes after s
78. rbono un gas inodoro y venenoso Respirar mon xido de carbono puede provocar dolor de cabeza fatiga mareos v mitos confusi n ataques n useas desmayos o incluso la muerte Opere el generador SOLAMENTE al aire libre Instale una alarma de mon xido de carbono con bater a cerca de los dormitorios Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio cerrado en el que puedan acumularse NO arranque ni deje funcionar el motor en interiores ni en zonas cerradas aunque haya ventanas y puertas abiertas incluyendo el compartimiento del generador en un veh culo recreativo o RV BRIGGSandSTRATTON COM ADVERTENCIA El escape del motor de este producto contiene elementos qu micos reconocidos en el Estado de California por producir c ncer defectos de nacimiento u otros da os de tipo reproductivo ADVERTENCIA El retroceso repliegue r pido del cable del arrancador puede producir lesiones El retroceso a impedir que el usuario suelte el cable a tiempo y tirar de su mano y brazo hacia el motor Como resultado podr an producirse fracturas contusiones o esguinces e Cuando arranque el motor tire lentamente del cable hasta sentir una resistencia y a continuaci n tire r pidamente de l para evitar su retroceso e NUNCA arranque o pare el motor cuando haya aparatos el ctricos conectados y en funcionamiento
79. recalentamiento e ignici n de los residuos acumulados e Utilice un trapo h medo para limpiar las superficies exteriores AVISO El tratamiento inadecuado del generador puede da arlo y acortar su vida productiva NO exponga al generador a una humedad excesiva polvo suciedad vapores corrosivos e NO inserte cualquier objeto a trav s de las ranuras de enfriamiento e Puede usar un cepillo de cerdas suaves para retirar la suciedad endurecida aceite etc e Puede usar una m quina aspiradora para eliminar suciedad y residuos sueltos Espa ol T pal F CD CD ea e e a n c a Mantenimiento del motor ADVERTENCIA Chispear involuntario puede tener como resultado el fuego o el golpe el ctrico CUANDO AJUSTE O HAGA REPARACIONES A SU M QUINA GENERADOR e Siempre desconecte el alambre de la buj a y col quelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR e Utilice un comprobador de buj as homologado e NO comprueba la chispa sin la buj a instalada Aceite Recomendaciones sobre el aceite Para obtener el mejor rendimiento recomendamos utilizar aceites certificados con garant a Briggs 4 Stratton Tambi n se pueden utilizar otros aceites detergentes de alta calidad con clasificaci n de servicio SF SG SH SJ o superior NO utilice aditivos especiales Las temperaturas exteriores determinan la viscosi
80. receipts covering maintenance on your small off road engine but B amp S cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance As the small off road engine owner you should however be aware that B amp S may deny you warranty coverage if your small off road engine or a part has failed due to abuse neglect improper maintenance or unapproved modifications You are responsible for presenting your small off road engine to an Authorized B amp S Service Dealer as soon as a problem exists The undisputed warranty repairs should be completed in a reasonable amount of time not to exceed 30 days If you have any questions regarding your warranty rights and responsibilities you should contact a B amp S Service Representative at 414 259 5262 The emissions warranty is a defects warranty Defects are judged on normal engine performance The warranty is not related to an in use emissions test Briggs amp Stratton Emissions Control Defects Warranty Provisions The following are specific provisions relative to your Emissions Control Defects Warranty Coverage It is in addition to the B amp S engine warranty for non regulated engines found in the Operator s Manual 1 Warranted Parts Coverage under this warranty extends only to the parts listed below the emissions control systems parts to the extent these parts were present on the engine purchased a Fuel Meterin
81. resi n salga del tanque Llene o vac e el dep sito de combustible a la intemperie NO llene demasiado el tanque Permita al menos espacio para la expansi n del combustible Si se ha derramado combustible espere a que se evapore antes de arrancar el motor Mantenga la combustible alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n NO encienda un cigarrillo o fume CUANDO PONGA EN FUNCIONAMIENTO EL EQUIPO Compruebe que la buj a el silenciador el tap n del dep sito de combustible y el filtro de aire est n instalados e NO arranque el motor sin la buj a instalada CUANDO OPERE EL EQUIPO e NO incline el motor o el equipo de tal manera que la combustible se pueda derramar e Este generador no es apto para el uso en equipos m viles ni en aplicaciones marinas CUANDO TRANSPORTE O REPARE EL EQUIPO e Transporte o repare el equipo con el tanque de combustible vac o o con la v lvula para apagar el combustible apagada posici n OFF e Desconecte el cable de la buj a CUANDO ALMACENE O GUARDE EL EQUIPO CON COMBUSTIBLE EN EL TANQUE e Almacene alejado de calderas estufas calentadores de agua secadoras de ropa u otros aparatos electrodom sticos que posean pilotos u otras fuentes de ignici n porque ellos pueden encender los vapores de la combustible ADVERTENCIA Este generador no cumple la norma 33CFR 183 del cuerpo de guardacostas de EE UU y no debe utilizarse en aplicaciones
82. riggs amp Stratton Power Products Group LLC 900 North Parkway Jefferson WI 53549 Copyright 2007 Briggs amp Stratton Power Products Group LLC Reservados todos los derechos Queda prohibida la reproducci n o transmisi n total o parcial de este material sea cual sea la forma y el medio empleados para ello sin el permiso previo y por escrito de Briggs amp Stratton Power Products Group LLC 2 BRIGGSandSTRATTON COM Tabla de Contenido Seguridad de operario 4 Descripci n del equipo 4 Reglas de seguridad 4 Montaje 1 Desembalaje del 7 Instale el juego de ruedas Agregar aceite al 8 Agregue 5 8 Tierra del sistema 0 Conexi n al sistema el ctrico de un edificio 9 Ubicaci n del 9 Controles y caracter sticaS 10 Juegos de cordones y enchufes conectores 11 Operando 12 Encienda 12 Conexi n de cargas el ctricas
83. roduce chispas humo o emite llamas La unidad vibra d iva CUANDO AJUSTE 0 HAGA REPARACIONES A SU MAQUINA GENERADOR Siempre desconecte el alambre de la buj a y col quelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR e Utilice un comprobador de buj as homologado e NO comprueba la chispa sin la buj a instalada 6 BRIGGSandSTRATTON COM Montaje Su generador requiere de ciertos procedimientos de montaje y solo estar listo para ser utilizado despu s de haberle suministrado servicio con el combustible y aceite recomendados Si usted tiene problemas con el montaje de su generador por favor llame a la l nea de ayuda para generadores al 800 743 4115 Si llamar para la ayuda tiene por favor el modelo la revisi n y el n mero de serie de etiqueta de datos disponible Consulte la ubicaci n en la secci n Controles y caracter sticas Desembalaje del generador 1 Coloque la caja de cart n en una superficie r gida y plana 2 Abra completamente la caja de cart n cortando cada una de sus esquinas de arriba abajo 3 Saque todo el contenido de la caja de cart n a excepci n del generador 4 Mantenga el generador sobre el cart n para instalar el juego de ruedas El generador se entrega con e Aceite del Motor e Manual del Operario e Juego de Ruedas Instale el juego de ruedas NOTA Este Juego de Ruedas no ha sido dise ado para ser usado en la carretera
84. s muy alta 1 Vea No Sobrerecarque Generador 2 Filtro de aire sucio 2 Reemplace el filtro de aire Carburador con mezcla de aire combustible muy rica o muy pobre motor le hace falta potencia El motor no funciona Contacte el distribuidor de servicio autorizado continuamente o se detiene 20 BRIGGSandSTRATTON COM Garant as Garant a del sistema de control de emisiones Briggs amp Stratton Corporation B amp S el California Air Resources Board CARB Consejo de recursos de aire de California y la United States Environmental Protection Agency U S EPA Agencia estadounidense de protecci n del medioambiente Declaraci n de garant a del sistema de control de emisiones derechos y obligaciones del propietario para la garant a contra defectos Garant a contra defectos del sistema de control de emisiones de California Estados Unidos y Canad California Air Resources Board CARB U S EPA y B amp S le explican a continuaci n la garant a del sistema de control de emisiones de su peque o motor para m quinas de servicio SORE Small Offroad Engine En California los modelos de peque os motores para m quinas de servicio a partir del a o 2006 deben estar dise ados fabricados y equipados conforme a los exigentes est ndares de lucha contra la contaminaci n del Estado En otros lugares de Estados Unidos los modelos de motores para m quinas de servicio con encendido por buj a a partir del 19
85. s pelados o recept culos NO use un generador con cables el ctricos que est n malgastados rotos pelados o da ados de cualquier forma NO opere el generador bajo la lluvia NO maneje el generador o cables el ctricos mientras est parado en agua descalzo o cuando las manos y los pies est n mojados NO permita que personas descalificadas o ni os operen o sirvan al generador Ubicaci n del generador Espacio libre alrededor del generador ADVERTENCIA Los gases y el calor de escape pueden inflamar los materiales combustibles y las estructuras o da ar el dep sito de combustible y provocar un incendio e Deje un espacio m nimo de 1 5 m 5 pies alrededor del generador incluida la parte superior Coloque la generador a la intemperie en una zona en donde no se acumulen gases de escape mortales NO instale el generador en lugares en los que los gases de escape A se puedan acumular o entrar en un edificio que pueda estar ocupado Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio cerrado en el que puedan acumularse Tenga en cuenta los vientos y las corriente de aire preponderantes cuando elija la ubicaci n del generador A PELIGRO El uso de un generador en un espacio interior PUEDE PROVOCAR LA MUERTE EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono un veneno invisible e inodoro
86. spark plug and place the wire where it cannot contact spark plug 3 Clean area around oil drain plug A The oil drain plug is located at base of engine opposite carburetor BRIGGSandSTRATTON COM 4 Remove oil drain plug and drain oil completely into a suitable container 5 Reinstall oil drain plug and tighten securely Remove oil fill cap 6 Slowly pour oil about 28 oz into oil fill opening B to the point of overflowing C at oil fill cap DO NOT overfill 7 Reinstall oil fill cap Finger tighten cap securely 8 Wipe up any spilled oil Service Air Cleaner Your engine will not run properly and may be damaged if you run it with a dirty air cleaner Replace the air cleaner every 25 hours of operation or once each year whichever comes first Replace more often if operating under dirty or dusty conditions To service the air cleaner follow these steps 1 Loosen screws D and remove air cleaner cover E 2 Carefully remove cartridge F from base G 3 Install clean or new air cleaner assembly inside cover Dispose of old filter properly 4 Assemble air cleaner cover onto base and tighten screws Service Spark Plug Change the spark plug every 100 hours of operation or once each year whichever comes first This will help your engine to start easier and run better 1 Clean area around spark plug 2 Remove and inspect spark plug 3 Check electrode gap with wire feeler gauge and res
87. t certificado para cumplir la normativa sobre emisiones durante 125 horas de funcionamiento real Intermedio El motor est certificado para cumplir la normativa sobre emisiones durante 250 horas de funcionamiento real Prolongado El motor est certificado para cumplir la normativa sobre emisiones durante 500 horas de funcionamiento real Por ejemplo un cortac sped con operario a pie se suele utilizar entre 20 y 25 horas al Por tanto el Per odo de Durabilidad de las Emisiones de un motor con clasificaci n intermedia equivaldr a a 10 12 a os Algunos motores cuentan con la certificaci n de cumplimiento de la fase 2 de las normas sobre emisiones de la United States Environmental Protection Agency USEPA Agencia estadounidense de protecci n del medioambiente En el caso de los motores con certificaci n de fase 2 el per odo de cumplimiento de la normativa sobre emisiones que figura en la etiqueta de cumplimiento de emisiones indica el n mero de horas de funcionamiento durante las cuales el motor ha demostrado cumplir los requisitos federales sobre emisiones Para motores de menos de 225 cc Categor a C 125 horas Categor a B 250 horas Categor a A 500 horas Para motores de 225 cc o m s Categor a C 250 horas Categor a B 500 horas Categor a A 1000 horas BRIGGSandSTRATTON COM POL TICA DE GARANT A PARA EL PROPIETARIO DE GENERADOR PORT TIL BRIGGS amp STRATTON POWER PRODUCTS GROUP LL
88. t a de vac os e NO utilice gasolina no autorizada por ejemplo E85 e NO mezcle aceite con gasolina e NO modifique el motor para hacerlo funcionar con otros combustibles Para evitar la formaci n de carbonilla en el circuito de combustible siempre que a ada combustible m zclelo con un estabilizador Consulte Almacenamiento No todos los combustibles son iguales Si detecta problemas de arranque o de rendimiento despu s de utilizar un combustible pruebe a cambiar de proveedor o de marca Este motor est certificado para funcionar con gasolina Su sistema de control de emisiones es EM Modificaciones del motor ADVERTENCIA La combustible y sus vapores son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras severas e inclusive la muerte CUANDO ANADA COMBUSTIBLE e Apague el generador posici n OFF y d jelo enfriar al menos por 2 minutos antes de remover la tapa de la combustible Afloje la tapa lentamente para dejar que la presi n salga del tanque Llene o vac e el dep sito de combustible a la intemperie NO llene demasiado el tanque Permita al menos espacio para la expansi n del combustible Si se ha derramado combustible espere a que se evapore antes de arrancar el motor Mantenga la combustible alejada de chispas llamas abiertas pilotos calor y otras fuentes de ignici n NO encienda un cigarrillo o fume 1 Limpie el rea alrededor de la tapa de
89. t the engine as described in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load 14 NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Wattage Reference Guide Rated Additional Running Surge Watts Starting Watts Tool or Appliance Light Bulb 75 watt 75 500 500 B00 1200 B00 1600 i009 209 1200 300 800 Microwave Oven 1000 Watt 1000 1500 1500 2500 450 Color Television 27 in 500 Personal Computer w 17 in 800 monitor 300 LY i000 1000 1000 1500 1800 1800 2000 2500 Wattages listed are approximate only Check tool or appliance for actual wattage 1800 1300 C1 NO 1200 1000 1500 1800 1800 2000 2500 i i O BRIGGSandSTRATTON COM Maintenance Maintenance Schedule Follow the hourly or calendar intervals whichever occurs first More frequent service is required when operating in adverse conditions noted below e Change engine oil Every 8 Hours or Daily e Clean debris e Check engine oil level Every 25 Hours or Yearly e Service engine air cleaner Ever
90. ta Circuito del generador en corto V lvula del combustible en posici n Off Interruptor balanc n poscioando en Off 3 Depurador de aire sucio 4 Sin gasolina 5 Gasolina vieja El cable de la buj a no est en malas la buj a Buj a defectuosa Agua en la gasolina Sobrecebado Mezcla de combustible excesivamente rica La v lvula de entrada est atascada est cerrada El motor ha perdido compresi n Accion Reposicione el interruptor Revise y repare Conecte otro dispositivo que est buenas condiciones Contacte el distribuidor de servicio autorizado Desconecte la carga el ctrica en corto Vea No Sobrerecarque Generador Contacte el distribuidor de servicio autorizado Contacte el distribuidor de servicio autorizado Gire la v lvula del combustible a la posici n Coloque del interruptor balanc n en On 3 Limpie o reemplace el depurador de aire 4 Ll nelo con combustible fresco 5 Drene el tanque de gasolina ll nelo con combustible fresco Conecte el cable a la buj a Reemplace la buj a Drene el tanque de gasolina ll nelo con combustible fresco Abra por completo el cebador y haga girar el motor Contacte el distribuidor de servicio autorizado Contacte el distribuidor de servicio autorizado Contacte el distribuidor de servicio autorizado 1 La carga e
91. tarting 2 Plug in and turn on the desired 120 and or 240 Volt AC single phase 60 Hz electrical loads NOTE DO NOT connect 240 Volt loads to the 120 Volt duplex receptacles e DO NOT connect 3 phase loads to the generator e DO NOT connect 50 Hz loads to the generator DO NOT OVERLOAD THE GENERATOR See Don t Overload Generator NOTICE Exceeding generators wattage amperage capacity can damage generator and or electrical devices connected to it DO NOT exceed the generator s wattage amperage capacity See Don t Overload Generator in the Operation section otart generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator Stopping the Engine 1 Turn OFF and unplug all electrical loads from generator panel receptacles NEVER start or stop engine with electrical devices plugged in and turned ON 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Push engine rocker switch to Off position y Backfire fire or engine damage could occur e DO NOT stop engine by moving choke control to Choke position Il 4 Move fuel valve to Off position 13 uone1adg Operation Don t Overload Generator Capacity You must make sure your generator can supply enough rated runnin
92. tration equipment equipment used for prime power in place of utility power equipment used in life support applications and failures due to acts of God and other force majeure events beyond the manufacturers control 198189E Rev B 12 31 2006 BRIGGS amp STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WI USA 23 BRIGGSSSTRATTON Portable Generator Product Specifications Starting Wattage 0 550 watts Wattage 5 550 watts Load Current at 120 MONS Soares uo rad 46 2 Amps at 240 VOUS i5 usu x rack cic ear one 23 1 Amps arc vu peroo aa daha eo E sa Single phase Rated Frequency 60 Hertz Shipping Weight 150 Ib 68 kg 18 61 305 Spark Plug Gap 0 030 0 76 Fuel Capacity 7 U S gallons 26 5 L Oil Capacity 28 Ounces 0 83 Liters Common Service Parts Air 4915885 or 5043D Resistor Spark Plug 4910555 Long Life Platinum Spark Plug 5066 Engine Oil Bottle 100005 xis PIC M bi ee ban OTT TIL LOT 5041D Spark Arrester 94945 Power Ratings The gross power rating for individual gas engine models is labeled in accordance with SAE Society of Automotive Engin
93. ut of fuel 4 Fill fuel tank Stale fuel 5 Drain fuel tank and carburetor fill with fresh fuel Spark plug wire not connected to spark 6 Connect wire to spark plug Engine will not start or starts plug and runs rough Bad spark plug Replace spark plug Water in fuel 8 Drain gas tank and carburetor fill with fresh fuel Hooded 9 Wait 5 minutes and re crank engine Excessively rich fuel mixture 10 Contact authorized service facility Intake valve stuck open or closed 11 Contact authorized service facility Engine has lost compression 12 Contact authorized service facility Engine shuts down when Out of fuel Fill fuel tank running 1 Load is too high 1 See Don t Overload Generator in Engine lacks power Operation section 2 Dirty air filter 2 Replace air filter Engine hunts or falters Carburetor is running too rich or too lean Contact authorized service facility 20 BRIGGSandSTRATTON COM Warranties Emissions Control System Warranty Briggs amp Stratton Corporation B amp S the California Air Resources Board CARB and the United States Environmental Protection Agency U S EPA Emissions Control System Warranty Statement Owner s Defect Warranty Rights and Obligations California United States and Canada Emissions Control Defects Warranty Statement The California Air Resources Board CARB U S EPA and amp 5 are pleased to explain the Emissions Control System Warranty on
94. y nacionales en materia de seguridad e higiene en el trabajo aplicables al uso del generador Consulte con un electricista cualificado un inspector el ctrico o el organismo competente e En algunas zonas es obligatorio registrar los generadores en las compa as el ctricas locales e Si el generador se utiliza en una obra puede ser necesario cumplir normas y requisitos adicionales Conexi n al sistema el ctrico de un edificio Las conexiones a efectos de alimentaci n de reserva al sistema el ctrico de un edificio deben ser realizadas por un electricista cualificado La conexi n debe aislar la alimentaci n del generador de la alimentaci n de la red p blica o de otra fuente de energ a alternativa y debe cumplir todas las leyes y normas el ctricas vigentes ADVERTENCIA Los generadores producen un voltaje muy poderoso Si no a sla el generador de utilidades de energ a puede hacer que los trabajadores de electricidad sufran heridas graves e inclusive la muerte debido a la retroalimentaci n de la energ a el ctrica Cuando use un generador como poder de energ a auxiliar notifique a la compa a de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad el ctrica Use un interruptor para la falla del circuito de tierra GFCI en cualquier rea bastante h meda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambre
95. y 50 Hours or Yearly e Change engine oil Every 100 Hours or Yearly e Service spark plug e Service spark arrester e Clean cooling system Every 250 Hours or Yearly e Check valve clearance 1 Service more often under dirty or dusty conditions General Recommendations Regular maintenance will improve the performance and extend the life of the generator See an authorized dealer for service The generator s warranty does not cover items that have been subjected to operator abuse or negligence To receive full value from the warranty the operator must maintain the generator as instructed in this manual Some adjustments will need to be made periodically to properly maintain your generator All service and adjustments should be made at least once each season Follow the requirements in the Maintenance Schedule chart above NOTE Once a year you should clean or replace the spark plug and replace the air filter A new spark plug and clean air filter assure proper fuel air mixture and help your engine run better and last longer Emissions Control Maintenance replacement or repair of the emissions control devices and systems may be performed by any non road engine repair establishment or individual However to obtain no charge emissions control service the work must be performed by a factory authorized dealer See the Emissions Warranty Generator Maintenance Generator maintenance consists of keeping the unit clean
96. your small off road engine SORE In California new small off road engines model year 2006 and later must be designed built and equipped to meet the otate s stringent anti smog standards Elsewhere in the United States new non road spark ignition engines certified for model year 1997 and later must meet similar standards set forth by the U S EPA B amp S must warrant the emissions control system on your engine for the periods of time listed below provided there has been no abuse neglect or improper maintenance of your small off road engine Your emissions control system includes parts such as the carburetor air cleaner ignition system fuel line muffler and catalytic converter Also included may be connectors and other emissions related assemblies Where a warrantable condition exists B amp S will repair your small off road engine at no cost to you including diagnosis parts and labor Briggs amp Stratton Emissions Control Defects Warranty Coverage omall off road engines are warranted relative to emissions control parts defects for a period of two years subject to provisions set forth below If any covered part on your engine is defective the part will be repaired or replaced by B amp S Owner s Warranty Responsibilities As the small off road engine owner you are responsible for the performance of the required maintenance listed in your Operating and Maintenance Instructions B amp S recommends that you retain all your
Download Pdf Manuals
Related Search
Related Contents
Kenmore 12-Year Energy Guide Installation manual DTB3185/10 Philips Microchaîne Manual Breast Pump General Notes All parts can be sterilised. 1 ZCM4821B Nortec NHPC User's Manual Definición Procesos Niveles 1 y 2 Pioneer PD-F19PD-F17 User's Manual operating instructions and owner`s manual Copyright © All rights reserved.