Home

Bosch D9124 User's Manual

image

Contents

1. Fire Alarm Systems D9124 Addressable Fire Alarm Control Panel FACP BOSCH Invented for life D9124 Addressable Fire Alarm Control Panel FACP BOSCH FIRE CONTROL PANEL COMMAND CENTER The D9124 FACP controls complex alarm systems used in schools universities manufacturing plants and health care facilities Program it for fire fire supervisory intrusion or access control applications Program it locally using the D5200CE hand held programmer or remotely using RPS over telephone lines or local area or wide area networks LAN or WAN The D9124 FACP is a modular assembly installed in a red steel enclosure which can be surface or flush mounted The enclosure has keyed controller access making it suitable for installation in public access areas Functions Alarm Verification The alarm verification feature reduces potential false alarms by requiring a reset and a second alarm signal from the device before the control panel raises an alarm condition Auxiliary and Standby Power The 4A 24 VDC power supply charges the standby batteries and powers auxiliary devices The power supply responds to low battery or battery disconnect conditions with a Trouble LED and a Trouble Relay for sounders or lights gt 24 VDC 4A power for initiation circuits and NACs 12 VDC 1 4 A power for system accessories gt Up to eight supervised or 32 unsupervised remote annunciators gt One man Fire Te
2. Modules eight re lay outputs per module On board NACs Two 1 8 A maximum per circuit Power Requirements Current operating Alarm sensor load 874mA Idle 412mA 24 VDC nominal at 1 8 A 120 VAC 60 Hz 360 VA Power auxiliary Power primary Ordering Information D9124 Addressable Fire Alarm Control D9124 Panel FACP Up to eight supervised or 32 unsupervised re mote annunciators Accessories D113 Battery Lead Supervision Module D113 Supervises wiring connections for two 12 V batteries connected tothe sameset of charging terminals D122 Dual Battery Harness D122 Harness with circuit breaker Connects two batteries to a compatible control panel D135A Low battery Disconnect Module Disconnects the control panel from the battery when the battery level drops to 9 5 VDC D135A www boschsecurity com 124 Addressable Fire Alarm Control Panel FACP Ordering Information D127 Reversing Relay Module D127 Reports two separate alarm conditions to the central station D136 Plug In Relay D136 Maximum rating is 1 Aat 24 VDC or 2 Aat 12 VDC Available individually D136 or ina package of 25 D136 25 D138 Mounting Bracket Right Angle D138 Used to mount accessory modules in D8103 D8108A and D8109 enclosures Americas Europe Middle East Africa Asia Pacific Represented by Bosch Security Systems Inc Bosch Security Systems B V Robert Bosch SEA Pte Ltd Security Systems 130 Perinton P
3. arkway P O Box 80002 11 Bishan Street 21 Fairport New York 14450 USA 5600 JB Eindhoven The Netherlands Singapore 573943 Phone 1 800 289 0096 Phone 31 40 2577 284 Phone 65 6258 5511 Fax 1 585 223 9180 Fax 31 40 2577 330 Fax 65 6571 2698 security sales us bosch com emea securitysystems bosch com apr securitysystems bosch com www boschsecurity us www boschsecurity com www boschsecurity com Bosch Security Systems Inc 2010 Data subject to change without notice 71113332363 Cur en US V5 4 Jul 2010
4. cks Another box contains Quant Component 1 D9101 Enclosure Assembly with Door The third box contains a D9100 Accessory Module Carrier that includes the following Quant Component 2 D192C Indicating Circuit Supervision Modules 1 D928 Dual Phone Line Switcher 1 D8125 POPEX Module additional optional 1 D9142LC 24 VDC Power Supply The third box also contains Quant Component D1256 Fire Alarm Keypad D1601 Transformer Wiring Harness Wiring Harness for the D8125 POPEX Module 560 0 Resistors for D192C Modules D161 Dual Modular Telephone Cords D162 Dual Modular Telephone Cord Literature pack PrP Mm NY PRP RP re D9124 Addressable Fire Alarm Control Panel FACP 3 Technical Specifications Environmental Considerations Relative Humidity Up to 85 non condensing Temperature operating 32 F to 122 F 0 C to 50 C Inputs Sensor Circuits Up to two 8125 POPEX modules 119 addresses per module Power limited to 4 A short circuit reverse polarity thermal overload and current over load protection on board Sensor Circuit Protection Sensor Loop Technology Four wire addressable circuits Mechanical Properties Color Red Material 16 gauge 1 5 mm steel Dimensions H x W x D 36 1 in x 22 1 in x 3 2 in 92 cmx 56 cmx 8 1 cm 37 1 in x 23 3 in x 1 1 in 94 cm x 59 cmx 2 8 cm Enclosure Box Removable Door Outputs Off board relays Up to 16 optional D8129 Relay
5. nt Log Storage Viewing and Printing The D9124 s memory log stores time date point and user ID for up to 1000 events Programming options allow restricting specific event reports to the central station receiver A programming option allows the log to record certain functions entered at command centers Display the 1000 events in memory at the fire system controller s or retrieve them with a single phone call by a central station using Bosch RPS version 3 7 025 or higher The D9131A Parallel Printer Interface Module allows an on site parallel printer to print events as they are stored in the log recording time date account number event point ID point text and if the message was transmitted to a receiver Inputs The D9124 Control Panel is a 127 point addressable system that is expandable to 246 addressable points The control panel receives information from alarm initiating points through integrated devices over a two wire multiplex zone expansion system Each addressable point accommodates both normally open and normally closed devices with end of line EOL resistor supervision Each point is programmable for fire fire supervisory intrusion or access control applications Outputs System notification appliance capacity can be extended beyond the two supervised circuits by adding D8129 Octo relay Modules Up to 128 relay outputs can be operated through the controller or the central station or they can be programmed for a
6. ply Products BATB 80 Battery box D126 12V 7 Ah standby battery D1218 12V 18 Ah standby battery D7038 Power supply address circuit module Detectors D285 Photoelectric smoke head D285TH Photoelectric smoke head with heat D298M Zonex smoke master base D298S Zonex smoke single base FMM 462 Manual station D603 Rate of rise heat detector head D604 Fixed 135 F heat detector head D605 Fixed 190 F heat detector head Keypadsand D720B R Security and fire keypads Annunciators D1255B R Security and fire keypads D1256 Fire command center D1257 Remote fire alarm annunciator D1260 ATM keypad Modules D125B Powered loop interface module Dual Class B D129 Initiation circuit module Dual Class A D130 Relay module D136 Plug in relay D192C Bell supervision module D192E Bell supervision module Category ProductID Product Description D192G Bell supervision module D8125 POPEX module D8125MUX Zonex to dual multiplex interface D8128D OctoPOPIT module D8129 Octo relay module D8130 Release module D9127U POPIT module no tamper D9127T POPIT module tamper D9131A Parallel printer interface module DX4020 Ethernet interface module Programming D5200CE Handheld programmer Products RPS Remote Programming Software RPS LITE Remote Programming Software RPS INTL Remote Programming Software Parts Included The D9124 Addressable Control Panel is shipped in three boxes One box contains Quant Component 1 D9412GLTB Control Panel less terminal blo
7. st Mode gt Schedules Skeds function service reminder for local systems gt Low battery AC power supply and battery lead supervision gt Dual phone line monitor Five system power trouble conditions are selected by DIP switches They can be individually linked to a central station or grouped to activate a trouble relay allowing a single supervised address to monitor the power supply A pair of 12 V batteries provides standby power Two additional batteries provide standby power for initiating devices and notification appliances All four batteries are housed within the panel enclosure Note Batteries are not included in the D9124 and must be purchased separately Central Station Communication Events can be communicated to a central station by the digital communicator or by adding an optional Ethernet interface module The optional Bosch D6500 or D6600 NetCom Receiver and Modem Illa reporting format provide individual point reporting to monitoring facilities The D5500 Remote Programming Software RPS allows the following to be controlled from a central station Resetting notification appliances Activating or deactivating remote annunciation Activating or deactivating relays Supervising battery condition Setting point status and armed status Enabling or disabling reporting functions Shunting reporting points during servicing www boschsecurity com 2 D9124 Addressable Fire Alarm Control Panel FACP Eve
8. utomatic operations Notification appliances can be programmed for steady pulsed California March Time or Temporal Code 3 patterns Temporal Code 3 patterns can be synchronized using the appropriate synchronization modules Notification Appliance Circuits NACs The D9124 FACP has two supervised on board NACs with individual circuit silencing User Interface A D1256 Fire Alarm keypad is visible and accessible behind a locked clear sliding panel located on the enclosure door It displays programmable text identifying specific initiating and supervisory devices It also provides point annunciation signal silence trouble silence detector reset and annunciator reset The sliding panel lock is keyed to match the Bosch manual pull stations for resetting the system Also available as options are e D1255R Security Fire Keypad e D1257 Remote Fire Alarm Annunciator e D1260 Keypad Certifications and Approvals Region Certification USA UL AMCX Central Station Alarm Units UL1610 UL1635 APAW Police Station Alarm Units UL365 UL464 UOJZ Control Units System UL864 FM CSFM 7165 1615 113 and 7170 1615 144 July 2008 12 92 E Vol IV 12 92 E Vol IV 12 92 E Vol X11 12 92 Vol 12 NYC MEA Hong Kong HKFSD Installation Configuration Notes Compatible Products The following products are compatible with the D9124 FACP Category ProductID Product Description Batteriesand BATB 40 Battery box Power Sup

Download Pdf Manuals

image

Related Search

Related Contents

Serie EX240-SDN1 EX240-SDN2  GUARDSMAN DORMANT SPRAY OIL GuardsmanMD est une  PureFlow GSX - アンリツネットワークス  4 PAGES BUSINESS Survie BAT.pub  Torq 2.0 User Guide - Beta 2.05  attention - GM Canada  MINILED-Supercharged_ISTR  Notice - Sterop  LG 47LY760H 47" Full HD Wi-Fi Metallic LED TV  manual de instalação Stûv 16  