Home

Black Box TV Converter Box BLACK BOX MULTIPOWER INDUSTRAL MEDIA CONVERTERS User's Manual

image

Contents

1. 40km LICO56A R2 TP TX SSFX SM1310 LONG SC 1310xmt 1550rcv 60km LICO57A R2 TP TX SSFX SM1550 LONG SC 1550xmt 1310rcv 60km Page 6 724 746 5500 blackbox com LICO22A R2 Chapter 1 Specifications 1 Specifications Ethernet Connections 10 100 BaseT Auto Negotiation Auto Cross Flow Control 1916 MTU Full Line Rate Forwarding DC terminal 7 to 50 VDC 1 to0 1A DC jack 5 VDC PoE When MultiPower Industrial Media Converters use PoE technology to be a PD the maximum supply voltage is 50V AC Wall Adapter 100 to 240 10 VAC input 5 VDC output 2A max Power Consumption 500mA 5 VDC Typical Operating Temperature DC configurations 13 F to 185 F 25 C to 85 C With AC wall adapter 14 F to 122 F 10 C to 50 C Storage Temperature 40 F to 185 F 40 C to 85 C Humidit 5 to 95 non condensing 0 83 Hx1 80 Wx3 35 D 2 11x4 57x8 51 cm LICO22A R2 724 746 5500 blackbox com Page Chapter 2 Overview 2 Overview About the MultiPower Industrial Media Converters The MultiPower Industrial Media Converters provide a single conversion between 10 100 Base T twisted pair and 100 Base SX FX fiber This device Auto Negotiates speed and duplex on the copper port and the fiber is 100Mbps FDX The unit supports jumbo frames up to 1916 MTU The MultiPower Industrial Media Converters are fixed fiber transceiver models that include one 10 100 Mbps RJ 45 connector and one 10 100 Mb
2. environment and human health For more detailed information about proper disposal please contact local authorities waste disposal services or the point of purchase for this equipment z blackbox com Page 4 724 746 5500 blackbox com LICO22A R2 Table of Contents Table of Contents PUNO CUS een 6 1 SPECE AION APA Renee eae eee age 7 2 Overview About the MultiPower Industrial Media Converters 8 3 Install the MultiPower Industrial Media ConverterS coccccccccncccoccncnno 9 3 1 DIN MODE NG ee A ANA NE 9 3 2 Cascading DE POWer unneeseneinneaenneneleugueer 9 3 3 Powering the MultiPower Industrial Media Converters 10 3 4 About Power over Ethernet PoE and MultiPower Industrial Media CONVE Sisa en 10 3 5 DC Terminal Block Wiring InstructiOnNS occcccocconccocononanononononnos 10 4 A ERENSEOLEEAERTRRENIERTRERERFERLHEREPERERERUERERRER 11 5 GOMTACTIING Black BOX nun ee ae eisen 12 6 Fiber Optic Cleaning Guidelines 00022222000220200 nennen 13 7 Electrostatic Discharge Precautions uus2uu002040snnnnennnne nenne nennen 14 LICO22A R2 724 746 5500 blackbox com Page 5 Part Numbers Part Numbers Number TP TX FX SM1310 LONG SC 80 km LICO52A R2 LICO53A R2 TP TX SSFX SM1550 SC 1550xmt 1310rcv 20km LICO54A R2 TP TX SSFX SM1310 PLUS SC 1310xmt 1550rcv 40km LICO55A R2 TP TX SSFX SM1550 PLUS SC 1550xmt 1310rcv
3. LICO22A R2 LICO26A R2 LICO54A R2 lt lt BL ACK BOX LICO23A R2 LICO27A R2 LICO55A R2 RQ LICO24A R2 LICO52A R2 LICO56A R2 NETWORK SERVICES LICO25A R2 LICO53A R2 LIC057A R2 Choose from four different ways to power these hardened media converters d Customer Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Support FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax Information 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com TRADEMARKS USED IN THIS MANUAL Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners Page 2 724 746 5500 blackbox com LICO22A R2 FCC and IC RFI Statements FCC and Industry Canada RF Interference Statements Class A using DC terminal power or Power over Ethernet PoE This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation However there is no guarantee that interference will not occur in a particular installation This equipment generates uses and can radiate radio frequency energy and if n
4. il order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Page 12 724 746 5500 blackbox com LICO22A R2 Chapter 6 Fiber Optic Cleaning Guidelines 6 Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust which can obstruct the optic path and cause performance degradation Good system performance requires clean optics and connector ferrules 1 Use fiber patch cords or connectors if you terminate your own fiber only from a reputable supplier low quality components can cause many hard to diagnose problems in an installation 2 Dust caps are installed at Black Box to ensure factory clean optical devices These protective caps should not be removed until the moment of connecting the fiber cable to the device If you need to disconnect the fiber device reinstall the protective dust caps 3 Store spare caps in a dust free environment such as a sealed plastic bag or box so that when reinstalled they do not introduce any contamination to the optics 4 If you suspect that the optics have been contaminated alternate between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt LICO22A R2 724 746 5500 blackbox com Page 13 Chapter 7 Electrostatic Discharge Precautions 7 Electrostatic Discharge Precautions Electrostatic di
5. locate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult an experienced radio TV technician for help CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment To meet FCC requirements shielded cables and power cords are required to connect this device to a personal computer or other Class B certified device This digital apparatus does not exceed the Class B limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada LICO22A R2 724 746 5500 blackbox com Page 3 Certifications Certifications Class 1 Laser product Luokan 1 Laserlaite Laser Klasse 1 Appareil A Laser de Classe European Directive 2002 96 EC WEEE requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the equipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the
6. ny one negative terminal on the MultiPower Industrial Media o Converters 5 VDC 7 to 50 VDC When using stranded wire the leads must be tinned and equivalent to a 16 AWG solid conductor The DC terminal block is protected against mis wiring Ifthe unit is mis wired positive power lead to the negative terminal and negative power lead to the positive terminal it will not function When powering a unit with voltages near the upper limit of the device s specification for example 48 volts take precautions to limit the voltage at the units terminal block When turning on high voltage DC circuits initial voltages may momentarily exceed the unit s specification Page 10 724 746 5500 blackbox com LICO22A R2 Chapter 4 Operation 4 Operation The MultiPower Industrial Media Converters include two LEDs located on the RJ 45 connector LED functions are as follows FA LNKALT p TX LNK ACT FX LNK ACT Glows green when a link is established on the fiber port TX LNK ACT Glows amber when a link is established on the copper port blinks amber when activity is detected on the copper port LICO22A R2 724 746 5500 blackbox com Page 11 Chapter 5 Contacting Black Box 5 Contacting Black Box Black Box Customer Service Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Free technical support 24 hours a day 7 days a week Call 724 746 5500 or Fax 724 746 0746 Ma
7. on products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 30 seconds or less Copyright 2012 Black Box Corporation All rights reserved Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any third party trademarks appearing in this manual are acknowledged to be the property of their respective owners 724 746 5500 blackbox com LICO22A R2 Rev 1 55 80722BB 00 Rev B3 Black Box Tech Support FREE Live 24 7 Tech support the way it should be _ Great tech support Is just 30 seconds away at 724 746 5500 or blackbox com BLACK BOX About Black Box Black Box provides an extensive range of networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 30 seconds or less Copyright 2012 Black Box Corporation All rights reserved Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any third party trademarks appearing in this manual are acknowledged to be the property of their respective owners 724 746 5500 blackbox com
8. ot installed and used in accordance with the instructions may cause harmful interference to radio communications If this equipment does cause harmful interference to radio or telephone reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult an experienced radio TV technician for help Class B using any DC jack options This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation However there is no guarantee that interference will not occur in a particular installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications If this equipment does cause harmful interference to radio or telephone reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures e Reorient or re
9. ps SC fiber connector which can support Single Mode fiber or Multi Mode fiber in Dual Strand or Single Strand fiber The MultiPower Industrial Media Converters are Industrial Ethernet devices which allows for extended temperature operation of 25 C to 85 C for DC power or 10 C to 50 C when using the AC adapter When installing the MultiPower Industrial Media Converters in an 18 slot tray or using DC power the temperature range supported is 13 F to 185 F 25 F to 85 F Page 8 724 746 5500 blackbox com LICO22A R2 Chapter 3 Install the MultiPower Industrial Media Converters 3 Install the MultiPower Industrial Media Converters The MultiPower Industrial Media Converters install virtually anywhere as standalone devices in locations with extremely limited space Installation options include e Velcro strips e DIN rail mounting with DIN Rail clips e PowerTray 18 for high density applications 3 1 DIN Rail Mounting The MultiPower Industrial Media Converters ship from the factory with DIN clips allowing installation on a DIN rail Depending on the installation the MultiPower Industrial Media Converters can be mounted parallel or perpendicular to the DIN rail Use the supplied screws to attach the DIN clips to the MultiPower Industrial Media Converters and then snap the converter to the DIN rail e o gt To remove the converter from the DIN rail use a flat head screwdrive
10. r in the slot to gently pry the converter from the rail NOTE The DIN clips are designed for use on a DIN 35 rail 3 2 Cascading DC Power When installing multiple MultiPower Industrial Media Converters on a DIN rail the end user can connect to one DC input source and then cascade from one DC block to the next until reaching the maximum current available LICO22A R2 724 746 5500 blackbox com Page 9 Chapter 3 Install the MultiPower Industrial Media Converters 3 3 Powering the MultiPower Industrial Media Converters The MultiPower Industrial Media Converters include multiple powering options e A country specific high reliability AC power adapter included e The IEEE 802 3af Power over Ethernet standard draws power from power sourcing equipment e The 4 terminal DC power block e IE PowerTray 18 Slot AC for Rack Mounting e USB cable e IE 5V DIN rail mount Power Supply 3 4 About Power over Ethernet PoE and MultiPower Industrial Media Converters Power over Ethernet technology allows the MultiPower Industrial Media Converters to be Powered Devices PD and draw power when connected to Power Sourcing Equipment PSE Power Sourcing Equipment distributes an electrical current across existing copper data cabling 3 5 DC Terminal Block Wiring Instructions 0600 0 The MultiPower Industrial Media Converters can also be powered with the DC terminal block From a power source connect to any one positive and a
11. scharge ESD can cause damage to any product add in modules or stand alone units containing electronic components Always observe the following precautions when installing or handling these kinds of products 1 Do not remove unit from its protective packaging until ready to install 2 Wear an ESD wrist grounding strap before handling any module or component Ifthe wrist strap is not available maintain grounded contact with the system unit throughout any procedure requiring ESD protection 3 Hold the units by the edges do not touch the electronic components or gold connectors 4 After removal always place the boards on a grounded static free surface ESD pad or in a proper ESD bag Do not slide the modules or stand alone units over any surface WARNING Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices Notes LICO22A R2 724 746 5500 blackbox com Page 15 Black Box Tech Support FREE Live 24 7 Tech support the way it should be Great tech support is just 30 seconds away at 724 746 5500 or blackbox com BLACK BOX About Black Box Black Box provides an extensive range of networking and infrastructure products You ll find everything from cabinets and racks and power and surge protecti