Home

Black Box Network Hardware EncrypTight Enforcement Point (ETEP) User's Manual

image

Contents

1. Table 21 ET0010A Null Modem Pin Connection 3 Receive Data 3 Transmit Data 6 Transmit Data 2 Receive Data 5 Signal Ground 5 Signal Ground ETEP Installation Guide 59 Maintenance RS 232 Serial Cable ET0100A ET1000A The RS 232 serial cable on the ET0100A and ET1000A is a null modem cable with DB 9 connectors female to male Figure 39 ET0100A ET1000A Null Modem Serial Cable PC CEP Female Male Table 22 ET0100A ET1000A Null Modem Pin Connection 2 Receive Data 3 Transmit Data 3 Transmit Data 2 Receive Data 5 Signal Ground 5 Signal Ground 60 ETEP Installation Guide 5 Troubleshooting This section includes the following topics e Symptoms and Solutions e Diagnostic Code Display Symptoms and Solutions The following tables provide some solutions to common problems that may occur with your ETEP LED Indicators Table 23 LED Indicators No power light Make sure the power cable is attached and plugged in to both the device and the power outlet Alarm light is lit The ETEP is in an error state See Error State on page 62 for information about possible causes and recovery procedures Port status LED is off no link Check the network cable Verify correct transmit and receive cable polarity Check the operational status of the equipment being connected Verify that the auto negotiation and flow control settings on the local or remote port in questio
2. Elements of Figure 11 1 Large screws 10 32 used to attach the mounting brackets to the rack 2 Small black screws used to attach the mounting brackets to the ETEP 3 Rubber feet used for solid surface installation 4 Small silver toned screws with built in washers used to attach rubber feet to the bottom of the ETEP Installation Instructions ET0010A The ET0010A can be mounted in a standard 19 inch rack using the mounting kit or simply placed on a rack shelf or solid surface Before installing the ETEP in a 19 inch rack review the mounting guidelines listed in ETEP Site Preparation on page 25 Rack Mount Installation To mount the ETEP in a standard 19 inch equipment rack have the following tools and materials available 28 ETEP Installation Guide Installing the ETO010A e External power supply e Two mounting brackets supplied in the Accessory Kit e 4 small black screws and 4 large 10 32 screws supplied in the Accessory Kit e 1 Phillips and 2 Phillips screwdrivers user supplied To install the ETEP in a rack 1 Place the unit on a solid surface with the bottom panel facing up When looking at the ET0010A from the bottom rear the bracket that holds the power supply is on the right as shown in Figure 12 Figure 12 Bottom rear view of the ET0010A with rack mount brackets Elements of Figure 12 1 Mounting bracket 2 Regulatory label on the bottom of the unit 3 Rear panel 4
3. Connecting the Cables ET0100A The procedure in this section describes how to connect the ET0100A to your network devices as shown in Figure 23 To cable the ET0100A 1 For initial setup connect the RS 232 port directly to a PC or workstation using a DB 9 null modem cable This cable can be removed after initial setup is complete 2 Connect the 10 100 Ethernet management port to a LAN using a Category 5 shielded twisted pair STP cable with an RJ 45 connector 3 Connect the remote port to the untrusted network typically via a router port using a Category 5 STP cable with an RJ 45 connector 4 Connect the local port to the local device such as a server or switch using a Category 5 STP cable with an RJ 45 connector ETEP Installation Guide 37 Installation Figure 23 ET0100A Cabling Remote port to Local port to Untrusted Network Trusted Network Router 10 100 Port _ 4 RS 232 Port wf Management Management PC for initial Workstation Network setup Powering on the ET0100A Use the following procedure to power up the ETO100A To power on the ET0100A e On the appliance s rear panel plug the power cord into the ET0100A power receptacle Attach the opposite end to a power source to apply power to the appliance Due to the shielding in the power cable you must exert significant pressure to properly insert the power cord into the ET0100A power receptacle A properly seated power cord canno
4. Policy Selector Options e Source or destination IP address Source or destination port number e Protocol ID Layer 3 IP packet and Layer 4 payload options VLAN ID Layer 2 encryption option e Multicast address Specifications This section lists the mechanical and environmental specifications for the following ETEP models e ET0010A specifications are listed in Table 6 e ETOI00A specifications are listed in Table 7 e ETI000A specifications are listed in Table 8 Table 6 ET0010A Mechanical and Environmental Specifications Interfaces 2 10 100 Mbps Ethernet ports for encrypting and decrypting traffic 1 10 100 Mbps Ethernet auxiliary port ETOO10A only not enabled 10 100 1000 Mbps auto sensing Ethernet LAN port for management RS 232 port for management 20 ETEP Installation Guide Specifications Table 6 ET0010A Mechanical and Environmental Specifications ET0010A 19 inch rack mount design Electrical Mechanical Dimensions 1u tamper evident chassis Dimensions 1 6 Hx 8 0 W x 5 8 D Weight without external power supply 1 pound 4 ounces External power supply Weight 11 ounces e Input voltage 100 240 VAC 1 5 amps 50 60 Hz auto sensing e Output voltage 12 VDC 5 amps Nominal input current 0 25 amps Nominal power dissipation 36 watts Thermal power In rush 102 BTU hour steady state 102 BTU hour Environmental Operating temperature 0 to 40 degrees C 32 to 104 degrees F Operating
5. on page 56 Obtaining a License for Replacement Units When replacing an ETEP with a spare the replacement ETEP will run at full throughput for a grace period During the grace period contact customer support to report the RMA unit and to receive a new license for the replacement Licenses are linked to the serial number of the ETEP on which they are installed You cannot install a license intended for one ETEP on a different ETEP Upon receipt of the new license install it on the ETEP as described in Entering a Throughput License on page 52 Replacing the ET1000A Power Supply The ET1000A comes with dual internal power supplies In the event of a failure cach power supply can be removed and replaced in the field AN CAUTION Disconnect all power cords before servicing the ET1000A To replace a power supply in the ET1000A 1 Unplug both power supplies at the power source 2 On the rear panel lift the power cord clip on the affected power supply and then remove the power cord from the receptacle Figure 35 56 ETEP Installation Guide What To Do If an Appliance Fails Figure 35 Power cord is removed from power supply 2 3 Locate the release lever on the left of the power supply Figure 36 Press the release lever inward toward the metal support to release the power supply latch Pull the power supply outward to remove it from the chassis Figure 36 Release lever on power supply 2 4 On the replacement
6. 2 Rear panel power connector ET0100A Physical Description The ETO100A is a rack mountable encryptor that can run at speeds ranging from 100 250 Mbps The following sections describe the connectors and LED indicators that appear on the front and rear panels of the ETO100A ETEP Installation Guide 13 Product Overview Front Panel Connectors The ET0100A front panel connectors are shown in Figure 5 Figure 5 ET0100A Front Panel Connectors Elements of Figure 5 1 10 100 Ethernet management port 2 RS 232 port 3 Remote port encrypted traffic 4 Local port clear traffic LED Indicators The ET0100A LED indictors are shown in Figure 6 The LED indications are described in Table 2 Figure 6 ET0100A LED Indicators Elements of Figure 6 1 Diagnostic display 2 Alarm LED 3 Link indicators 4 Power indictor 14 ETEP Installation Guide ET0100A Physical Description The following table describes how to interpret the LEDs on the ETO100A front panel Table 2 ET0100A Front Panel LED Indicators Power green Off Unit is powered off On Unit is powered on Ethernet port status Off Loss of signal on the 10 100 link arena On The link is up but no traffic is passing over the link Blinking Indicates the presence of traffic on the 10 100 link Gigabit link status amber Off Loss of signal on the Gigabit link On The Gigabit link is up but no traffic is passing over the link
7. Blinking Indicates the presence of traffic on the Gigabit link Alarm green Off Normal operation On The unit is in an error state This occurs when the diagnostics detect a boot failure a critical error threshold is exceeded or a FIPS test fails when the ETEP is in FIPS mode Diagnostic code display On Displays diagnostic codes during boot up After boot up it reflects the operational state of the appliance and error conditions a The link status LEDs are on the remote and local data ports and Ethernet management port Rear Panel The ETO100A rear panel is shown in Figure 7 Figure 7 ET0100A Rear Panel Elements of Figure 7 1 Power receptacle 2 Fan 3 Product ID label ETEP Installation Guide 15 Product Overview ET1000A Physical Description The ET1000A is a rack mountable 1 Gbps encryptor with dual power supplies It can operate at speeds ranging from 500 Mbps 1 Gbps The following sections describe the ET1000A connectors and LED indicators Front Panel Connectors The ET1000A front panel connectors are shown in Figure 8 Figure 8 ET1000A Front Panel Connectors BLACK BOX amp nagerert meme men biackbnn com Ethernet woe fie ese FJ fo fe Elements of Figure 8 1 RS 232 serial port 2 10 100 Ethernet management port 3 Gigabit Ethernet management port not enabled in this release 4 Aux1 port not enabled in this release 5 Remote port encrypted traffic 6 Local port clear
8. 1 75 H x 17 W x 15 5 D Weight 10 pounds 100 240 VAC 3 1 5A 47 63 Hz auto sensing Nominal input power 72 watts Maximum power 90 watts Nominal input current 0 65 A 110V Thermal power single power supply In rush 266 BTU hour steady state 222 BTU hour Thermal power dual power supplies In rush 440 BTU hour steady state 263 BTU hour Environmental Operating temperature 0 to 40 degrees C 32 to 104 degrees F Operating humidity Up to 90 non condensing Operating altitude 200 to 10 000 feet AMSL Regulatory See ET1000A Regulatory Information on page 68 ETEP Installation Guide 2 Installation This section includes the following topics Before You Start Installing the ETO010A Installing the ETO100A Installing the ET1000A Shutting Down the ETEP Before You Start Before you prepare the ETEP for installation review the following information Safety Guidelines on page 23 e Software Requirements on page 24 e ETEP Site Preparation on page 25 e Firewall Ports on page 26 Safety Guidelines The ETEP does not contain any field replaceable internal parts Do not remove the unit s cover for any reason The cover is to be removed only by authorized Black Box service personnel Authorized service personnel should review the following safety information prior to performing service or maintenance procedures on the ETEP AN CAUTION Disconnect all power cords be
9. Check that the power supply cable is properly inserted in the power connector on the ETEP rear panel The ETO010A is shown in Figure 21 2 Plug the power cord into the ETEP power supply Attach the opposite end to a power source to apply power to the appliance When the appliance powers up all LEDs illuminate The power LED remains lit until the unit is powered off During the boot process the ETEP cycles through its startup tests and the corresponding status LEDs are illuminated see Status Codes ETOO10A on page 63 After the tests execute successfully the status indicators turn off NOTE During the boot process the ETEP discards all traffic on its data ports Once the appliance is operational the default mode of operation passes all packets in the clear until you deploy security policies Installing the ET0100A To prepare the ETO100A for installation review the installation steps in Table 13 unpack the shipping carton and prepare a space for the installation of the appliance The steps to perform for a typical installation are listed below Table 13 ET0100A Installation Steps 1 Review the cabling requirements on page 35 3 Prepare a space for installation of the ET0100A on page 36 5 Apply power to the ET0100A on page 38 Cabling Requirements ET0100A Table 14 outlines the standard cables used with each port on the ET0100A The connector type listed indicates only what is required to connect to t
10. It is strongly recommended that you change the default passwords when you configure the ETEP for operation For more information about user management see the documentation for your management software ETEP CLI User Guide or the EncrypTight User Guide Configuring the Management Port 48 The ETEP can be managed in line or out of band through a dedicated Ethernet management interface Management port configuration consists of the following items e Setting the IP address and default gateway e Reviewing the auto negotiation settings About the management port IP address mask and gateway The management port must have an assigned IP address in order to be managed remotely and communicate with other devices An IPv4 IP address is mandatory even when the ETEP is operating in an IPv6 network When the ETEP is operating in an IPv6 network configure the ETEP for dual homed operation by assigning an IPv4 and an IPv6 address to the management port ETEP Installation Guide Configuring the Management Port The Ethernet management port P address identifies the ETEP to the management workstation The subnet mask is the portion of the IP address that identifies the network or subnetwork for routing purposes When the ETEP management port and the management workstation are on different subnets the ETEP uses a default gateway to route packets to the other devices The default gateway identifies the local router port that is on the same subnet as
11. and the ETEPs XML RPC TCP 443 Used for communications between Yes EncrypTight components Installing the ET0010A This section describes how to install ETOO10A To prepare the ETOO10A for installation review the installation steps in Table 11 unpack the shipping carton and prepare a space for the installation of the 26 appliance ETEP Installation Guide Installing the ETOO10A The steps to perform for a typical installation are listed below Table 11 Installation Steps 1 Review the cabling requirements on page 27 2 Unpack the shipping package on page 27 9 Install the ETEP in a rack or on a solid surface on page 28 4 Connect the cables on page 33 5 Apply power to the ETEP on page 34 Cabling Requirements ET0010A Table 12 outlines the standard cables used with each port on the ETEP The connector type listed indicates only what is required to connect to the ETEP port and may or may not be the same connector type required for the other end of the cable Some cables are supplied by Black Box and others are user supplied Table 12 ET0010A Standard Cables Power receptacle Power supply and power cable Black Box RS 232 port 1 8 meter shielded null modem Black Box cable with an RJ45 connector at one end and a DB9 female connector at the opposite end Ethernet Management Port Unshielded Category 5 straight Black Box through cable UTP RJ 45 connectora Aux1 port Not applicable Por
12. uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help ETEP Installation Guide 67 Environmental and Regulatory Information Interference Causing Equipment Standard Compliance Notice Canada The Class B digital apparatus complies with Canadian ICES 003 Cet appareil numerique de la class B est conforme a la norme NMB 003 du Canada European Notice Products with the CE Marking comply with both the EMC Directive 2004 108 EC and the Low Voltage Directive 2006 95 EC issued by the Commission of the European Community ET0100A Cabling A WARNING Use only shielded cables to connect I O devices to this equipment You are cautioned that changes or modifications not expressly approved by the party responsi
13. Alarm LED illuminates The ETEP sends a critical error trap The ETEP discards all packets that it receives on the local and remote ports Ethernet management port communication is disabled You will be unable to manage the ETEP using ETEMS CLI login is disabled via the serial port and Ssh Data files are permanently deleted including log files The file system is reset to factory defaults The zeroization process takes about 20 minutes to complete ETEP Installation Guide Cable Pinouts To recover the ETEP following zeroization Wait approximately 20 minutes for the zeroization process to complete If you are connected to the ETEP through the serial port you will see the following message Power cycle required to reboot appliance After cycling the power you will be able to configure and manage the ETEP from its factory default settings If you cycle the power prior to the completion of the zeroization process the appliance will enter an unrecoverable state which requires returning the ETEP to the factory Related topic e filesystem reset on page 132 Cable Pinouts This section lists the serial cable pinouts for the following ETEPs e ET0010A e ET0100A ETI000A RS 232 Serial Cable ET0010A The RS 232 serial cable on the ET0010A is a null modem cable with an RJ 45 connector to the ET0010A and a DB 9 female connector to a PC or laptop Figure 38 ET0010A Null Modem Serial Cable RJ 45 DB 9 female CEP10 PC
14. Firmware and software is factory installed on the unit 2 Accessory Kit e Rack mount kit containing two mounting brackets and 10 screws 1 Power cable US 1 Shielded DB 9 null modem cable female to male 1 Shielded Category 5 straight through cable STP with RJ 45 connector CD containing user documentation and a backup copy of the ETEP software Rack Mount Installation ET0100A The ET0100A can be mounted in a standard 19 inch rack using the mounting kit or simply placed on a rack shelf or solid surface Before installing the ETO100A in a 19 inch rack review the rack mounting guidelines listed in ETEP Site Preparation on page 25 36 ETEP Installation Guide Installing the ETO100A To mount the ETEP in a standard 19 inch equipment rack have the following tools and materials available e Two mounting brackets supplied in the Accessory Kit e 6 small screws and 4 large screws supplied in the Accessory Kit e 1 Phillips and 2 Phillips screwdrivers user supplied To install the ETEP in a rack 1 Attach a mounting bracket to each side of the ETEP near the front panel Attach each bracket with three small screws provided in the Accessory Kit using a 1 Phillips screwdriver 2 Attach the ETEP to the rack s front supports with the large screws using a 2 Phillips screwdriver Figure 22 Insert two screws in each bracket using the top and bottom holes Figure 22 Rack Mounted ETEP Front Panel View
15. Milia A ne det era de n nnn tnde dn ela ed 63 Diagnostic Codes ETO100A and ET1000A senem 64 Appendix A Environmental and Regulatory Information eeeeeeeeeeees 65 WEEE Directive i LE EU te deti enim NE 65 ROHS Directive 2 7 ditta tttm e cem eit etin ciet 65 Regulatory InformaltiOli 5 a ca euet e ate ime Tite c e T RERO 66 ET0010A Regulatory Information nennen nnne nns 66 SIM rS 66 MM EE 66 EMISSIONS pai PE a AAE een 66 ECC Information USA ao dabei es ect cer ted ene ea ia 66 Interference Causing Equipment Standard Compliance Notice Canada 67 EuropeanNotice 2 1 fai avis iii ia ee eat i eee lee 67 ET0100A Regulatory Information eeeeeee ee ennte eee eee enneeeeeeeeaeeeeeeeeaeeeseeeaaeeeeeeenaeeeeeseaaes 67 Safety ese hall Le ed Adee 67 MUNI Y titi tio eoe ttt rente or iaa 67 EMISSIONS MALUM 67 ECG information USA enm eer ettet E ee E e Re AA pe ERRORES 67 Interference Causing Equipment Standard Compliance Notice Canada 68 European Notice ncc Eo eet e et DE 68 4 ETEP Installation Guide Table of Contents ETOT00A CAbliNGs ist ini rte cn re eran eigen 68 ET1000A Regulatory Information sss eene eene enne 68 Safely tandi tee dt edo perd etel eee eli Lelio tudo 68 EMI EMG di tuit dec Cub cci Ca da MED 68 EGC Information USA ep nei ele tee tuae
16. bo ett eap aae qu dale e Aia 69 Interference Causing Equipment Standard Compliance Notice Canada 69 European Notice tiie nii eer eo piena i e utm ttd 69 Normas Oficiales Mexicanas NOM Electrical Safety Statement i 69 po T ARA 71 ETEP Installation Guide 5 Table of Contents 6 ETEP Installation Guide About This Document Purpose The ET VSE series Installation Guide describes how to cable and install the Black BoxTM ETEP EncrypTight Enforcement Points Intended audience This document is intended for use by network technicians and security administrators who are familiar with setting up and maintaining network equipment Assumptions This document assumes that its readers have an understanding of the following e Basic principles of TCP IP networking including IP addressing switching and routing e Personal computer PC operation and common PC terminology e Terminal emulation software and FTP operations Conventions used in this document Bold Indicates one of the following e a menu title e the name of a command e the name of a parameter Italics Indicates a new term Monospaced Indicates machine text such as terminal output or a file name Monospaced bold Indicates a command to be issued by the user Contacting Black Box Technical Support Contact our FREE technical support 24 hours a day 7 days a week Phone 724 746 5500 Fax 724 746 0746 e mail info blac
17. e HER eed t dee C e Hr ne eee 45 Chapter 3 Initial Set p etre eren nea Exo YR Ren YR iia 47 OVOIvIOW fesit fec de b en La o EL EUR 47 Logging In Through a Serial Link i 47 Configuring the Management Port enne ennemi nennen nennen enne 48 Setting the Date and Time iii 51 Entering a Throughput License ie 52 Configuration Exatnple cedes id iui 53 Managing the ET EP ereu ui i a ae D na eie a e a eaaet 53 Chapter MCEIIICGHEI UD 55 Preventative Maintenance 4 ii 55 What To Do If an Appliance FailS nn eenenmeem m emene nnne nnne eent 56 Obtaining a License for Replacement Units emm nens 56 Replacing the ET1000A Power Supply eee nennen nennen 56 Tamper Switch and Zeroization sss nennen nn nennen nennen nennen nns 58 Gable Pinouts n pde telnet des 59 RS 232 Serial Cable ET0010A ener enne rent nnn senes 59 RS 232 Serial Cable ETO100A ET1000A enne nnne 60 Chapter 5 Troubleshooting erint ci nnt anna oim au kV irrita 61 Symptomis and Solutions one iere etu i t E RE MEN 61 EED IndiCators t t eh be Dip e dle te E M NER taba qeu brise 61 Error atenas ta t Up metet mi fente nd rare dd rel Sage Nea 62 Temperature Threshold and Discarded Traffic sss 62 Diagnostic Code DISplay dati tud iet ire ttt esa Ee tidad 63 Status Codes ETOOT0OA
18. encrypted throughput rates of 3 6 10 25 and 50 Mbps e ETO100A Supports encrypted throughput rates of 100 155 and 250 Mbps e ET1000A Supports encrypted throughput rates of 500 650 and 1000 Mbps Encryption Support Advanced Encryption Standard AES FIPS 197 256 bit keys e 3DES ANSI X9 52 168 bit keys standard CBC mode User configurable for Layer 2 Ethernet or Layer 3 IP encryption with option to encrypt only the Layer 4 payload Authentication Methods e X 509 v3 digital certificates management interface HMAC SHA 1 96 e HMAC MD5 96 Encapsulation Modes e Layer 2 Ethernet payload encryption e Layer 3 IPSec Tunnel mode with original IP header preservation PSec Transport mode for Layer 4 payload encryption option Device Management ETEP Installation Guide e EncrypTight software for device and policy management e Out of band management Alarm condition detection and reporting e Syslog support SNMPv2c and SNMPv3 managed object support Audit logging Management access using X 509 v3 digital certificates Security options include TLS SSH IKE IPsec Product Overview Table 5 ETEP Feature Summary e Ethernet e VLAN tag preservation Network Support MPLS tag preservation e Jumbo frame support ETO100A CEP100 XSA CEP1000 ET1000A e Link state pass through e Pv4 e IPv6 Layer 2 Ethernet encryption mode e NTP Host or gateway packet reassembly option
19. for power supply 1 is secured with a clip ETEP Installation Guide Shutting Down the ETEP When the appliance powers up all of the front panel LEDs illuminate see Figure 33 The Alarm LED illuminates briefly and the diagnostic code LED displays 88 to verify that the diagnostic display segments are functioning The power LED remains lit until the unit is powered off The Power Supply LEDs illuminate for each operational power supply During the boot process the ET1000A cycles through its startup tests and the corresponding diagnostic codes are displayed see Diagnostic Codes ETO100A and ET1000A on page 64 After the tests execute successfully the diagnostic code display is solidly illuminated with code 00 LA NOTE o During the boot process the ET1000A discards all traffic on its data ports Once the appliance is operational the default mode of operation passes all packets in the clear until you deploy security policies Figure 33 ET1000A Front Panel Status Indicators 1 2 4 e I x BLACK BOX m Management wwe blackbea e Ethernet doh 3 Elements of Figure 33 1 Alarm LED 2 Diagnostic display 3 Power indicator 4 Power supply LEDs Shutting Down the ETEP It is important that a proper system shutdown is performed prior to powering off the appliance The shutdown command halts all running tasks on the ETEP and prepares it for being powered off Failure to perform a shutdown may lead
20. in this section e For EncrypTight deployments throughput licenses must be managed with the EncrypTight software Licenses entered from the CLI are not recognized as valid in an EncrypTight deployment See the EncrypTight User Guide for more information Each ETEP is capable of transmitting traffic at a range of speeds that varies by model When you install the license you purchased ETEPs transmit traffic at the speed specified by the license Table 20 lists the available speeds for each ETEP model Table 20 ETEP Throughput Speeds ET0010A 3 6 10 25 50 Mbps ET0100A 100 155 250 Mbps ET1000A 500 650 Mbps 1 Gbps 52 ETEP Installation Guide Configuration Example You need to install a license on each ETEP that you use Licenses are linked to the serial number of the ETEP on which they are installed You cannot install a license intended for one ETEP on a different ETEP If you upgrade from a command line only installation to a full EncrypTight deployment you can no longer use the command line only license and must acquire an EncrypTight license To add a license from the command line 1 At the command prompt type configure to enter configuration mode 2 Atthe config gt prompt type license lt string gt where string is the license provided by Customer Support The license is case sensitive Enter the license exactly as provided It will look something like this 1 0 0508C482 10 258482fab2 To view the ETEP throughput
21. of the error message on the console and then contact Black Box customer support Table 25 ET0010A Self Tests 2 amp 4 LED display test 1 Bootflash CRC test 2 DRAM test 1 1 2 Initialize IO devices DRAM test 2 3 Initialize compact flash 1 3 Complete bootloader initialization 2 3 Download operating system 1 2 8 Start operating system IPSec dataplane code and management and control software All status LEDs off Up and operational After the ET0010A boots up the status LEDs reflect the operational state of the appliance Table 26 ET0010A Operational Codes All status LEDs off Up and operational The ET0010A is in a shutdown state ETEP Installation Guide 63 Troubleshooting Diagnostic Codes ET0100A and ET1000A The 7 segment diagnostic display on the front panel of the following models displays self test codes during boot up ETO100A and ET1000A After the ETEP boots the display reflects the operational state of the appliance and error conditions When the appliance powers up all LEDs illuminate The Alarm LED illuminates briefly and the diagnostic code LED displays 88 to verify that the diagnostic display segments are functioning As the ETEP cycles through its self tests the corresponding diagnostic code is displayed see Table 27 After the tests execute successfully the diagnostic code display is solidly illuminated with code 00 If the ETEP fails to boot proper
22. power supply press the release lever toward the metal support and insert the new power supply until it latches Figure 37 When the power supply is correctly inserted you should not be able to remove it by pulling on it It can only be removed when the latch is disengaged ETEP Installation Guide 57 Maintenance Figure 37 Slide the replacement power supply into the slot on the rear panel 5 Insert the power cord in the replacement power supply and secure it with the clip 6 Reconnect power supplies and 2 to their respective power sources 7 Return the failed power supply to Black Box as directed by Customer Support Tamper Switch and Zeroization 58 The following ETEP models include a tamper switch ETOO10A ET0100A and ET1000A The switch is activated if the ETEP cover is removed while the unit is operating or if the ETEP detects that the cover is open while it is booting When the ETEP detects that the switch is activated it enters an error state zeroizes the appliance s keying material and discards all traffic Zeroization has the same effect as issuing the filesystem reset command Zeroization occurs under the following conditions When operating in FIPS mode the FIPS self tests fail during boot When operating in FIPS mode signature errors are detected on critical files pertaining to policies and keys e The tamper switch is activated when the cover is removed The following events occur when the ETEP is zeroized
23. traffic LED Indicators The ET1000A LED indicators are shown in Figure 9 The LEDs are described in Table 3 16 ETEP Installation Guide ET1000A Physical Description Figure 9 ET1000A LED Indicators 1 3 4 Elements of Figure 9 1 Power LED 2 Alarm LED 3 Diagnostic display 4 Link indicators 10 100 Ethernet management port 5 Link indicators Gigabit management port 6 Link indicators Aux1 Remote and Local ports 7 Power supply status LEDs Table 3 describes how to interpret the LEDs on the ET1000A front panel Table 3 ET1000A Front Panel LED Indicators Power green Unit is powered off Unit is powered on Alarm green Normal operation The unit is in an error state This occurs when the diagnostics detect a boot failure a critical error threshold is exceeded or a FIPS test fails Diagnostic code display Displays diagnostic codes during boot up After boot up it reflects the operational state of the appliance and error conditions 10 100 link status green Loss of signal on the 10 100 link The 10 100 link is up but no traffic is passing over the link Blinking Indicates the presence of traffic on the 10 100 link Gigabit link status green Loss of signal on the Gigabit link On The Gigabit link is up but no traffic is passing over the link Blinking Indicates the presence of traffic on the Gigabit link Power supply status Off Power supply is not operat
24. 0nm nominal wavelength LC connector Not applicable Available as accessory options Local and Remote Gigabit Ethernet ports e Copper SFP transceivers Shielded Category 5 straight through cable STP RJ 45 connector Available as accessory options Aux1 port SFP Not applicable Port is not enabled in this release Not applicable a The 10 100 Ethernet management port is auto sensing for polarity You can use a shielded Category 5 straight through cable or a shielded crossover cable when connecting to this port 40 ETEP Installation Guide Installing the ET1000A TF NOTE To meet the requirements of FCC Part 15 and the EU EMC Directive 2004 108 EC use only shielded Category 5 cables with the ET1000A Ethernet management port Unpacking the Shipping Carton ET1000A Remove all product components from the shipping carton and compare the contents to the packing list Keep all packaging in case it is necessary to return the unit The ET1000A is packaged with the standard items listed below Additional cables country specific power cords SFPs and other accessories can be ordered separately A list of approved transceivers is included in the ETEP Release Note 1 ET1000A chassis e Firmware and software is factory installed on the unit 2 Accessory Kit e Rack mount kit includes 2 mounting brackets 4 large screws 10 32 and 8 small black screws 2 Power cables US e 1 6 ft shielded DB 9 null modem cab
25. Cables ET0010A Follow the instructions below to connect the ETOO10A to the appropriate network devices see Figure 20 To cable the ET0010A 1 For initial setup connect the RS 232 serial port directly to a PC or workstation Using the null modem cable supplied by Black Box insert the RJ 45 connector in the RS 232 port and connect the DB 9 female connector to your PC This cable can be removed after initial setup is complete 2 Connect the Ethernet management port to a LAN using a Category 5 cable with an RJ 45 connector 3 Connect the remote port to the untrusted network typically via a router port using a Category 5 cable with an RJ 45 connector 4 Connect the local port to the local device such as a server or switch using a Category 5 cable with an RJ 45 connector ETEP Installation Guide 33 Installation Figure 20 ET0010A Cabling Remote port to Local port to Untrusted Network Trusted Network Router Switch ETEP 4 10 100 Port wf PC for initial Management Management setup Network Workstation RS 232 Port NOTE The Aux1 port on the ETOO10A is not enabled in this release Powering On the ET0010A Use the following procedure to power up the ETEP Figure 21 Attaching the power cables on the ET0010A Power cord connector Power supply cable on power supply connector on rear panel 34 ETEP Installation Guide Installing the ETO100A To power on the ETEP
26. ETOO10A e e ETO100A lt gt BLACK BOX mE NETWORK SERVICES Customer Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Support FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Inf ti Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 SCALA Web site www blackbox com E mail infoO blackbox com Table of Contents About This Docutmient 2 ocio ce co nia iii 7 Contacting Black Box Technical Support 7 Chapter 1 Product Overview ore rr alain 9 EMEP MMtrOG UC OM cti A aa E aa a aa 9 ET0010A Physical Description 3 iscrivi dada did 11 Front Panel Gonnectors liana 11 Status INCICALOrSs ptm 12 Rear Panel eiziiu anali iaia aiar 13 ETO100A Physical Descriptio voii idos 13 Front Panel Connectors i 14 LED Indicators ata a iaia a 14 Rear Panel iii 15 ET1000A Physical Description iii iaia 16 Front Panel Connectors diit t At at il ba 16 LED Indicators ee te eerte a ep ate iai pede RR EN lcd sm een 16 arcuum O 18 dlc 19 Specifications na insae M 20 Ghapter2 Installationi ai cc 23 Before You Start iii 23 Safety GUIdElimes ti parata iaia 23 Software Requirements 24 ETEP S
27. FF FE58 743 64 2001 DB8 20F F7FF FE84 BFC2 man if exit config Setting the Date and Time Setting the date and time on the ETEP helps ensure that the appliance s time can be synchronized properly with other ETEPs or components in the EncrypTight system The time zone on the ETEP is set to UTC 0 Coordinated Universal Time and is not user configurable Enter the date and time relative to UTC 0 also referred to as Greenwich Mean Time GMT To calculate ETEP Installation Guide 51 Initial Setup the local time relative to UTC add or subtract the offset hours from UTC for the local time zone UTC n The following examples give the local time at various locations at 12 00 UTC when daylight saving time is not in effect e New York City United States UTC 5 07 00 e New Delhi India UTC 5 30 17 30 To set the date and time 1 At the command prompt type configure to enter configuration mode 2 Atthe config gt prompt type date lt year gt lt month gt lt day gt lt hour gt lt minutes gt lt seconds gt year 2008 2037 month 01 12 day 01 31 hour 00 23 minutes 00 59 seconds 00 59 3 Type exit to return to the command prompt Example admin gt configure config gt date 2008 10 11 15 30 00 config gt exit Entering a Throughput License The method for entering licenses on the ETEP depends on your management software e For ETEPs that are managed exclusively through the command line follow the procedure
28. Power supply connector 5 Mounting bracket with power supply cradle 6 Front panel 2 Attach the mounting brackets to each side of the unit using the four small black screws provided in the Accessory Kit item 2 in Figure 11 and a 1 Phillips screwdriver When looking at the ETOO10A from the bottom rear the bracket that holds the power supply is on the right as shown in Figure 13 ETEP Installation Guide 29 Installation Figure 13 Attach mounting brackets to the bottom panel ET0010A is shown below Front panel Rear panel 3 Turn the ETEP face up and locate the external power supply With the label side facing down place the power supply in the mounting bracket cradle and snap it into place as shown in Figure 14 Figure 14 Power supply installed in mounting bracket cradle on the ET0010A Front panel gt Right mounting bracet 4 Connect the power supply cable to the rear panel connector Figure 15 shows the ET0010A power connector 30 ETEP Installation Guide Installing the ETO010A Figure 15 Insert the power supply cable into the connector on the rear panel Medel 410 092 4000 BM DIAS DE input LV v 5A Attach the mounting brackets to the rack s front supports with the large 410 32 screws item 1 in Figure 11 using a 2 Phillips screwdriver Insert two screws in each bracket using the top and bottom holes Figure 16 Front view of ET0010A mounting brackets and power supply Solid Surface Ins
29. Tight User Guide for more information about using ETEPs in a EncrypTight deployment The third party software listed in Table 9 is used when managing the ETEP in a standalone deployment See the EncrypTight User Guide for additional third party software you may want to install when using in EncrypTight to manage EncrypTight appliances Table 9 Third party management station software FTP server Copies files to and from Microsoft FTP server included EncrypTight appliances with Windows XP including log files and new firmware SFTP server optional available Secures file transfers to and Cerberus FTP Server 4 with ETEP 1 6 and later from EncrypTight appliances Professional Edition PDF reader Opens the user documentation Adobe Acrobat Reader version files on the product CD 6 0 or higher Free download available from www adobe com SSH client ETEPs Securely connects to the ETEP PuTTY included with the CLI ETEMS installation 24 ETEP Installation Guide Before You Start ETEP Site Preparation Most ETEP models can be mounted in a standard 19 inch rack using the supplied mounting kit or simply placed on a rack shelf or solid surface Before installing the ETEP in a 19 inch rack consider the following guidelines Ambient temperature Install the ETEP in an environment compatible with the 40 C maximum recommended ambient temperature Extra clearance above or below the unit on the rack is not required however be aware t
30. aightforward point to point topologies Figure shows ETEPs deployed in a multipoint Ethernet network EncrypTight includes the following components e EncrypTight Element Management System ETEMS for appliance configuration and management e EncrypTight Policy Manager ETPM for policy definition and deployment e EncrypTight Key Management System ETKMS for key generation and distribution ETEP Installation Guide ET0010A Physical Description ET0010A Physical Description The ETOO10A is a rack mountable encryptor that can run at speeds ranging from 3 50 Mbps It has three data ports on the front panel labeled Remote Local and Aux1 The following sections describe the ET0010A connectors and LED indicators Front Panel Connectors The ETOO10A front panel connectors are shown in Figure 2 Figure 2 ET0010A Front Panel Connectors ET D M EncrypTight www blackbox com sae Aut R po Alarm EIN Powsr 10 3 ETODIDA Status Elements in Figure 2 1 RS 232 management port 2 Ethernet management port 3 Auxiliary port not enabled in this release 4 Remote port encrypted traffic 5 Local port clear traffic ETEP Installation Guide 11 Product Overview Status Indicators The ETOO10A status indictors are shown in Figure 3 The status indications are described in Table 1 12 Figure 3 ET0010A Status Indicators 1 2 3 www blackbox com BLACK BOX Management EncrypTight per ER Aux1 Remote Loc
31. al e e e LJ Power 1 3 L L I L I Status ETODIDA EE ee 1 4 Elements of Figure 3 Power LED Alarm LED 2 3 4 Status indicators Link indicators The following table describes how to interpret the ET0010A status indicators Table 1 ET0010A Status Indicators Power green Off Unit is powered off On Unit is powered on 10 100 link status Off Loss of signal on the 10 100 link CIRCE On The 10 100 link is up but no traffic is passing over the link Blinking Indicates the presence of traffic on the 10 100 link Gigabit link status Off Loss of signal on the Gigabit link eles On The Gigabit link is up but no traffic is passing over the link Blinking Indicates the presence of traffic on the Gigabit link Alarm green Off Normal operation On The unit is in an error state This occurs when the diagnostics detect a boot failure a critical error threshold is exceeded or a FIPS test fails when the ETEP is in FIPS a mode Status 1 2 3 4 Off Unit is up and operational On Displays diagnostic codes during boot up The link status LEDs are on the remote and local data ports Ethernet management port and Aux1 port ETEP Installation Guide ET0100A Physical Description Rear Panel The ET0010A rear panel and external power supply are shown in Figure 4 Figure 4 ET0010A Rear Panel and External Power Supply Elements of Figure 4 1 External power supply power connector
32. an Notice Products with the CE Marking comply with the European Council Directive 2004 108 EC Normas Oficiales Mexicanas NOM Electrical Safety Statement INSTRUCCIONES DE SEGURIDAD 1 10 1 ha Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que el aparato el ctrico sea operado Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura Todas las advertencias en el aparato el ctrico y en sus instrucciones de operaci n deben ser respetadas Todas las instrucciones de operaci n y uso deben ser seguidas El aparato el ctrico no deber ser usado cerca del agua por ejemplo cerca de la tina de ba o lavabo s tano mojado o cerca de una alberca etc El aparato el ctrico debe ser usado nicamente con carritos o pedestales que sean recomendados por el fabricante El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las instrucciones de operaci n Todo otro servicio deber ser referido a personal de servicio calificado El aparato el ctrico debe ser situado de tal manera que su posici n no interfiera su uso La colocaci n del aparato el ctrico sobre una cama sof alfombra o superficie similar puede bloquea la ventilaci n no se debe colocar en libreros o gabinetes que impidan el flujo de aire
33. anagement port During that time you cannot enter any CLI commands When the operation is complete the man if gt prompt is displayed Optional If the ETEP is operating in an IPv6 network you can also assign an IPv6 address to the management port To do so type ip6 lt ip address gt lt prefix length gt gateway ip address IPv6 address of the ETEP management port This is a 128 bit address consisting of eight hexadecimal groups that are separated by colons Each group is a 4 digit hexadecimal number The hexadecimal letters in IPv6 addresses are not case sensitive prefix length A decimal value that indicates the number of contiguous higher order bits of the address that make up the network portion of the address The decimal value is preceded by a forward slash gateway IPv6 address of the router port that is on the same local network as the ETEP management port Auto negotiation is enabled by default If you want to disable auto negotiation and manually set the link speed and flow control configure the autoneg command Attributes are described in Table 19 autoneg enable disable lt speed gt lt flow control gt Type exit to return to the config prompt or type top to return to the command prompt ETEP Installation Guide Setting the Date and Time Table 19 Management port autoneg command description enable Enables auto negotiation on the management port This is the default setting disable Di
34. as not been cleared and the ETEP continues to discard traffic 62 ETEP Installation Guide Diagnostic Code Display If the ETEP is discarding traffic check the system log for temperature warning notices to confirm that a temperature error occurred Reboot the ETEP to resume normal operation Diagnostic Code Display ETEPs display self test codes during boot up in addition to operational status and error conditions See the following sections for information about your appliance model e Status Codes ET0010A on page 63 e Diagnostic Codes ET0100A and ET1000A on page 64 Status Codes ET0010A The ETOO10A status LEDs display self test codes during boot up After the ET0010A boots the status LEDs reflect the operational state of the appliance When the appliance powers up the Alarm LED illuminates briefly and the four status LEDs illuminate to verify that they are functioning As the ET0010A cycles through its self tests the status LEDs indicate the self test that is in progress see Table 25 After the tests execute successfully the status LEDs turn off If the ETOO10A fails to boot properly the illuminated status LEDs indicate the number of the last test that completed successfully and a message describing the failure is displayed on the terminal In addition the Alarm light illuminates if any of the first four self tests fail status LEDs 1 2 1 amp 2 or 3 In the event of a failure make a note of the status code and
35. ble for compliance could void your authority to operate the equipment ET1000A Regulatory Information The ET1000A part number 410 032 103 has received statements of compliance for the items listed in the following sections e Application of Regulations FCC Title 47 Part 15 Subpart B US Canada Standard ICES 003 European Council Directive 2004 108 EC e Class of Equipment Class B Safety UL 60950 1 2nd Edition 2007 03 27 CSA C22 2 No 60950 1 07 2nd Edition 2007 03 IEC 60950 1 2nd Edition EN 60950 1 2006 A11 2009 EMI EMC ANSI C63 4 2003 FCC Title 47 Part 15 Subpart B Canada Standard ICES 003 European Council Directive 2004 108 EC EN55022 2006 A1 2007 Class B EN61000 3 2 2006 EN61000 3 3 1995 A1 2001 A2 2005 68 ETEP Installation Guide Regulatory Information EN 55024 1998 A1 2001 A2 2003 IEC 61000 4 2 1995 A2 2000 IEC 61000 4 3 2002 IEC 61000 4 4 2004 IEC 61000 4 5 1995 A1 2000 IEC 61000 4 6 1996 A1 2000 IEC 61000 4 8 1993 A1 2000 IEC 61000 4 11 1994 A1 2000 Australian Standard AS NZS CISPR 22 2006 Class B FCC Information USA This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC rules Interference Causing Equipment Standard Compliance Notice Canada The Class B digital apparatus complies with Canadian ICES 003 Cet appareil numerique de la class B est conforme a la norme NMB 003 du Canada Europe
36. erence that may cause undesirable operation 66 ETEP Installation Guide Regulatory Information Interference Causing Equipment Standard Compliance Notice Canada The Class A digital apparatus complies with Canadian ICES 003 Cet appareil numerique de la class A est conforme a la norme NMB 003 du Canada European Notice Products with the CE Marking comply with both the EMC Directive 2004 108 EC and the Low Voltage Directive 2006 95 EC issued by the Commission of the European Community ET0100A Regulatory Information The ET0100A part number 410 032 002 has received a statement of compliance for the items listed in the following sections e Application of Regulations FCC Title 47 Part 15 Subpart B EMC Directive 2004 108 EC e Class of Equipment Class B Safety e UL 60950 1 e CSA C22 2 No 60950 1 Immunity e EN 55024 1998 A1 2001 A2 2003 IEC 61000 4 2 1995 A2 2000 IEC 61000 4 3 2002 IEC 61000 4 4 2004 IEC 61000 4 5 1995 A1 2000 IEC 61000 4 6 1996 A1 2000 IEC 61000 4 8 1993 A1 2000 IEC 61000 4 11 1994 A1 2000 Emissions e EN55022 2006 ANSI C63 4 2006 EN61000 3 2 2006 EN61000 3 3 1995 A1 2001 A2 2005 FCC Information USA This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates
37. erformance become available ETEP Installation Guide 65 Environmental and Regulatory Information For more information on the status of our RoHS efforts or product specific environmental questions please e mail us at info blackbox com Regulatory Information This section contains regulatory information for the following Black Box appliances e ET0010A e ET0100A e ETI000A ET0010A Regulatory Information The ET0010A part number 410 032 402 has received a statement of compliance for the items listed in the following sections e Application of Regulations FCC Title 47 Part 15 Subpart B EMC Directive 2004 108 EC e Class of Equipment Class A Safety e UL IEC 60950 1 2005 Second Edition EN 60950 1 2006 e CSA C222 No 60950 1 Immunity EN 55024 1998 A1 2001 A2 2003 IEC 61000 4 2 1995 A2 2000 IEC 61000 4 3 2002 IEC 61000 4 4 2004 IEC 61000 4 5 1995 A1 2000 IEC 61000 4 6 1996 A1 2000 IEC 61000 4 8 1993 A1 2000 IEC 61000 4 11 1994 A1 2000 Emissions FCC Part 15 Subpart B Class A EN55022 2006 Class A EN61000 3 2 2006 EN61000 3 3 1995 A1 2001 A2 2005 AS NZS CISPR 22 2006 Class A FCC Information USA This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC rules Operations are subject to the following conditions e This device may not cause harmful interference e This device must accept any interference received including interf
38. etup of the ETEP 1 2 3 4 Log in through a serial link Configure the management port Set the date and time Enter the throughput license Logging In Through a Serial Link Initial setup is performed through a serial link to the RS 232 port The initial setup commands are available to the Admin and Ops users The procedures and examples in this chapter assume that the Admin user is performing the setup tasks ETEP Installation Guide 47 Initial Setup To log in to the CLI via a serial link 1 Connect the RS 232 serial port directly to a PC or workstation as described in Chapter 2 2 Open a terminal session through a VT 100 terminal emulation program such as HyperTerminal Enter the connection name the appropriate serial port usually COM1 or COM2 and the following serial port parameters Baud Speed 38 400 Parity None Data Bits 8 Stop Bits 1 Flow Control None In the terminal session window press ENTER The login prompt displays Linux 2 6 16 17 on mips pep login At the login prompt type the default user name admin and press ENTER User names and passwords are case sensitive At the password prompt type the default password admin and press ENTER When you are successfully logged in the command line prompt displays as shown below password text is not displayed pep login admin Password Last login Tue Jan 29 19 18 59 2008 on ttyS0 Welcome admin it is Tue Jan 29 19 37 12 UTC 2008 admin gt
39. f life management solution that meets the European Union s Waste Electrical and Electronic Equipment WEEE Directive All products shipped from the Black Box manufacturing facility have the appropriate WEEE markings and qualify for the recycling program Black Box products that have reached the end of their useful life are to be recycled Send all requests for recycling to Black Box and we will arrange for pick up and transport to a recycling location that complies in an environmentally responsible manner with the EU WEEE Directive RoHS Directive The Restriction of Hazardous Substances RoHS Directive restricts the use of certain materials that are commonly found in electronic products Restricted substances are heavy metals including lead and poly brominated materials Black Box has eliminated or substantially reduced its usage of the prohibited materials However the RoHS Directive allows a lead in solder exemption for Category 3 Telecommunications Products It is Black Box s position that its network security products qualify for the lead in solder exemption Black Box is committed to completely eliminating its use of RoHS prohibited materials as that becomes technically feasible We are constantly monitoring the availability of lead free components and the progress of the lead free manufacturing processes We pledge to continually evolve and refine our products and processes as viable alternatives that do not impact product reliability or p
40. figuration policy definition and deployment and key generation and distribution To prepare the ETEP for operation in the network you will need to perform the following tasks 1 Assign passwords 2 Configure the ETEP 3 Define security policies If you plan to operate the ETEP in FIPS mode we recommend enabling FIPS mode as your first configuration task Entering FIPS mode resets many configuration items such as passwords policies and certificates To avoid having to reconfigure the ETEP enable FIPS mode and then perform the rest of the appliance and policy configuration tasks See the user guide for your management software for details e ETEP CLI User Guide e EncrypTight User Guide ETEP Installation Guide 4 Maintenance This section includes the following topics Preventative Maintenance What To Do If an Appliance Fails Tamper Switch and Zeroization Cable Pinouts Preventative Maintenance Periodically perform maintenance on your ETEP Keep components free of dust and other particulate matter Examine cables for damage and ensure that airflow requirements have been met On ETEP models that have fans check the fans for reduced airflow caused by dust build up and clean as necessary No special maintenance is required The ETEP is housed in a tamper evident chassis Periodically check the chassis for evidence of tampering Items to look for include stripped screws and damage to the tamper evident seal The tamper evide
41. fore servicing ETEP Installation Guide 23 Installation A WARNING The ETEP contains a lithium battery which users should not attempt to replace Battery replacement must be performed by qualified Black Box personnel Risk of explosion if battery is replaced by an incorrect type Used batteries should be disposed of according to the manufacturer s instructions AN CAUTION Electrostatic discharge ESD can damage electronic components and equipment ESD occurs when electronic components are improperly handled and can result in complete or intermittent failures Always follow ESD prevention procedures when removing and replacing components Qualified service personnel should use the following guidelines to prevent ESD damage e Always use an ESD wrist or ankle strap and ensure that it makes skin contact e Connect the equipment end of the strap to an unpainted metal chassis surface e Ifno wrist strap is available ground yourself by touching the metal chassis Software Requirements ETEP software is factory installed on the appliance A backup copy of the software is provided on the ETEP CD To learn how to reinstall your software or install an update refer to the user guide for your management software If you are using EncrypTight to manage your ETEPs you will need to install the EncrypTight software on the management station to configure the ETEPs for network operation and to create and deploy policies See the Encryp
42. hat equipment placed in the rack beneath the ETEP can add to the heat load Therefore avoid installing in an overly congested rack Air flowing to or from other equipment in the rack might interfere with the normal flow of cooling air through the ETEP increasing the potential for overheating Air flow Make sure that there is sufficient flow of air around the ETEP so that safe operation is not compromised Maintain a clearance of at least 3 inches 7 62 cm at the sides of the ETEP to ensure adequate air intake and exhaust If installing in an enclosed rack make sure the rack has adequate ventilation or an exhaust fan An enclosed rack with a ventilation system that is too powerful can prevent proper cooling by creating negative air pressure around the ETEP Mechanical Loading Keep the center of gravity in the rack as low as possible This ensures that the weight of the ETEP will not make the rack unstable Make sure that the rack is secured and use the proper mounting hardware to secure the ETEP to the rack Circuit Loading Consider the connection of the ETEP to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring Consult the voltage and amperage ratings on the UL label affixed to the unit s rear panel when addressing this concern Grounding Maintain reliable grounding of a rack mounted ETEP Pay particular attention to supply connections other than direct connections to
43. he ET0100A port and may or may not be the same ETEP Installation Guide 35 Installation connector type required for the other end of the cable Some cables are supplied by Black Box and others are user supplied Table 14 ET0100A Standard Cables Power receptacle Black Box Power supply cable certified and approved for use in the country of interest RS 232 Port Shielded copper null modem Black Box cable RS 232 DB9 connector female to male 10 100 Ethernet Management Port Shielded Category 5 straight Black Box through cable STP RJ 45 connector Remote and Local ports Shielded Category 5 straight User through cables STP RJ 45 connector a The local remote and Ethernet management ports are auto sensing for polarity You can use shielded Category 5 straight through cables or crossover cables when connecting to these ports NOTE To meet the requirements of FCC Part 15 and the EU EMC Directive 2004 108 EC use only shielded cables with the ETO100A DB 9 null modem cables and Category 5 STP cables Unpacking the Shipping Carton ET0100A Remove all product components from the shipping carton and compare the contents to the packing list Keep all packaging in case it is necessary to return the unit The ETO100A is packaged with the standard items listed below Additional cables country specific power cords and other accessories can be ordered separately 1 ETO100A chassis e
44. humidity Up to 90 non condensing Operating altitude 200 to 10 000 feet AMSL Regulatory See ET0010A Regulatory Information on page 66 Table 7 ET0100A Mechanical and Environmental Specifications Interfaces 2 10 100 1000 Mbps Ethernet ports for encrypting and decrypting traffic 10 100 Mbps auto sensing Ethernet LAN port for management RS 232C port for management Electrical Mechanical 19 inch rack mount design Dimensiene 1U tamper evident chassis Dimensions 1 75 H x 17 W x 10 D Weight 6 pounds 100 240 VAC 4 amps 50 60 Hz auto sensing Nominal input current 1 0A Nominal power dissipation 65 watts Thermal power In rush 380 BTU hour steady state 140 BTU hour Environmental Operating temperature 0 to 40 degrees C 32 to 104 degrees F Operating humidity Up to 90 non condensing Operating altitude 200 to 10 000 feet AMSL Regulatory See ET0100A Regulatory Information on page 67 ETEP Installation Guide 21 Product Overview 22 Table 8 ET1000A Mechanical and Environmental Specifications Interfaces 2 Gigabit Ethernet ports for encrypting and decrypting traffic single mode multimode or copper 10 100 Mbps auto sensing Ethernet LAN port for management RS 232C port for management 1 Auxiliary Gigabit port for data traffic not enabled 1 Gigabit Ethernet port for management not enabled ET1000A 19 inch rack mount design e 1U tamper evident chassis Dimensions
45. ional Possible causes include power supply unplugged power supply removed from chassis or a malfunction On Power supply is operational a Gigabit links include the remote and local data ports gigabit Ethernet management port and Aux1 port ETEP Installation Guide 17 Product Overview Rear Panel The ET1000A rear panel is shown in Figure 10 Figure 10 ET1000A Rear Panel Elements of Figure 10 Power Supply 2 1 Release lever for power supply 2 2 Power supply 2 receptacle 3 Power cord clip for power supply 2 4 Status LED for power supply 2 Green indicates normal operation Red indicates a power fail state Power Supply 1 5 Power cord clip for power supply 1 6 Status LED for power supply 1 Green indicates normal operation Red indicates a power fail state 7 Release lever for power supply 1 8 Power supply 1 receptacle 18 ETEP Installation Guide Features Features ETEPs share many of the same features and capabilities across hardware models as shown in Table 5 Hardware differences between the ETEP models are summarized in Table 4 Table 4 ETEP Hardware Comparison ET0010A 1u rack 2 3 50 RJ 45 RJ 45 Yes No mount Mbps ET0100A 1u rack 2 100 RJ 45 RJ 45 No No mount 250 Mbps ET1000A 1u rack 2 500 SFP RJ 45 and Yes Yes mount 1000 Mbps SFP The ETEP features are summarized in Table 5 Table 5 ETEP Feature Summary Throughput e ET0010A Supports
46. is your source for more than 118 000 networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 30 seconds or less Copyright 2011 All rights reserved Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any third party trademarks appearing in this manual are acknowledged to be the property of their respective owners ETOO10A Installation Guide version 1 724 746 5500 blackbox com
47. ite Preparate a ie 25 Firewall Ports i 26 Installing the E TOOVOA er ed ie deett iii 26 Cabling Requirements ETOOTOA iioii date tet re rdi d aee td c ate d e hai gd date teen 27 Unpacking the Shipping Carton ET0010A nennen 27 Installation Instructions ET0010A nnne emere nnn en nnns 28 Rack Mount Installation eo tr ena n bee orb side iran 28 Solid Surface Installation recte n obtenu d eek eer rh Rad tu YN dde airada da 31 Connecting the Cables ETO010A cia 33 Powering On the ETOO TOA Lucia 34 Installing the ETO100A enne nennen nnn en rre 35 Cabling Requirements ETOTOOA litre iii 35 Unpacking the Shipping Carton ET0100A ene ener 36 Rack Mount Installation ETO100A nennen rere trennen 36 Connecting the Cables ETO100A nene eene nennen innen nennen nnne neis 37 Powering on the ETOTQOOA cited gesimo eti ortas iaia i 38 Installing the ET1000A i 39 Cabling Requirements ET1000A ii 40 Unpacking the Shipping Carton ET1000A eene 41 Rack Mount Installation ET1000A ccc ccesce ee sesseeeseeseeuseeesesauaeessauaeeeeeeesueaeeeaaaeeeeaeaes 41 Table of Contents Connecting the Cables ET1000A nrden rie een aenea SE EEEE EEROR EENET E TEE 42 Powenng onthe ET 000A 5 Ite iP Re a RE alia 43 ShuttingiDown the E TEP eree ee
48. kbox com Web site www blackbox com ETEP Installation Guide About This Document 8 ETEP Installation Guide 1 Product Overview This section includes the following topics ETEP Introduction ET0010A Physical Description ET0100A Physical Description ET1000A Physical Description Features Specifications ETEP Introduction The EncrypTight Enforcement Point ETEP Variable Speed Encryptors VSEs are purpose built encryption appliances that provide multi layer data protection With straightforward setup and configuration the ETEP has the flexibility to provide Ethernet frame encryption for Layer 2 networks IP packet encryption for Layer 3 networks and Layer 4 data payload encryption for MPLS networks The ETEP s variable speed capability lets you enable just the bandwidth you need using a software license As your bandwidth needs increase simply update your license No need to replace your hardware The ET VSE series offer full duplex line rate encryption from 3 Mbps to 1 Gbps using the AES 256 encryption algorithm ETEP Installation Guide 9 Product Overview 10 Figure 1 Multipoint Ethernet Encryption using EncrypTight Business Partner EncrypTight Encryption Group 1 Encryption Groups 1 amp 2 Headquarters D q 7 MAA PE rx ae Encrypted Carrier z Network m Data Center s Regional Office Encryption Group 2 Encryption Group 2 il n Branch Office Branch Office Encryption Group 2 Encryption Gr
49. larm LED illuminates and the appliance discards all packets it receives Depending on the error other notifications may be sent traps status messages to the ETEMS or the terminal To recover from an error state when FIPS mode is disabled e When the ETEP detects a corrupted policy it enters an error state and sends a critical error trap to the management station To recover redeploy the policies and then reboot the ETEP For non policy errors reboot the appliance If the operating temperature threshold is exceeded cycle the power to restart the ETEP e Ifa failure occurs during the boot process refer to Diagnostic Code Display on page 63 for additional troubleshooting information e If the actions listed above do not clear the error contact customer support To recover from an error state when the ETEP is in FIPS mode AFIPS test failure or signature error will cause the ETEP to zeroize To learn more about the zeroization process and recovery from that state see Tamper Switch and Zeroization on page 58 Temperature Threshold and Discarded Traffic When the ETEP enters an alarm state due to a temperature failure the Alarm indicator illuminates and the ETEP discards traffic The ETEP remains in an error state until it is rebooted However once the temperature drops below the critical threshold the alarm indicator turns off and the ETEP stops reporting an alarm state to ETEMS even though the alarm state h
50. le female to male e 1 6 ft shielded Category 5 straight through cable STP with RJ 45 connector e CD containing user documentation and a backup copy of the ETEP software Rack Mount Installation ET1000A The ET1000A can be mounted in a standard 19 inch rack using the mounting kit or simply placed on a rack shelf or solid surface Before installing the ET1000A in a 19 inch rack review the rack mounting guidelines listed in ETEP Site Preparation on page 25 To mount the ET1000A in a standard 19 inch equipment rack have the following tools and materials available e Two mounting brackets supplied in the Accessory Kit e 8 small black screws and 4 large 10 32 screws supplied in the Accessory Kit e 1 Phillips and 2 Phillips screwdrivers user supplied AN CAUTION In order to safely and securely and install the ET1000A in a rack you must use the mounting brackets supplied in the Accessory Kit Other brackets may fail to properly support the weight of the ET1000A ETEP Installation Guide 41 Installation To install the ET1000A in a rack 1 Place the unit on a solid surface with the top facing up Position the mounting brackets on each side of the appliance as shown in Figure 27 Figure 27 Mounting bracket orientation 2 Attach the mounting brackets to each side of the unit using the 8 small black screws provided in the accessory kit and a 1 Phillips screwdriver as shown in Figure 28 Figure 28 Each bracke
51. ly the diagnostic code display indicates the number of the last test that completed successfully and a message describing the failure is displayed on the terminal In addition the Alarm light illuminates if diagnostic tests 01 04 fail In the event of a failure make a note of the code and of the error message on the console and then contact Black Box customer support Table 27 ETO100A ET1000A Self Tests 7 segment display test Bootflash CRC test 02 DRAM test 7H 03 Initialize IO devices DRAM test 2 04 Initialize compact flash 05 Complete bootloader initialization 06 Download operating system 07 Start operating system IPSec dataplane code and management and control software 00 Up and operational After the ETEP boots up the diagnostic display reflects the operational state of the appliance Table 28 ET0100A ET1000A Operational Codes 00 Up and operational rb The ETEP is in a reboot required state AL An alarm condition or error condition has been reported dL The ETEP is downloading new software ES The ETEP is in a shutdown state 64 ETEP Installation Guide Appendix A Environmental and Regulatory Information This section includes the following topics e WEEE Directive e RoHS Directive e Regulatory Information WEEE Directive Black Box is committed to environmentally responsible behavior As part of this commitment we have put in place a product end o
52. manually setting the ETEP link speed configure the speed and duplex mode to match that of the other device On the management port the ETEPs can negotiate to the following link speeds Table 18 Link speeds on the management port 10 Mbps Half duplex 10 Mbps Full duplex 100 Mbps Half duplex 100 Mbps Full duplex ETEP Installation Guide 49 Initial Setup Table 18 Link speeds on the management port 1000 Mbps Full duplex v 1000 Mbps Half duplex v To configure the management port 1 2 3 50 At the command prompt type configure to enter configuration mode At the config gt prompt type management interface Assigning an IPv4 address to the management port is mandatory To set the management port IPv4 address mask and gateway type ip lt ip address gt lt subnet mask gt gateway ip address Management port IP address entered in dotted decimal notation subnet mask IP subnet mask entered in dotted decimal notation gateway Specifies how to route traffic between the ETEP management port and the management station When the management port is on a different subnet than the management station specify the IP address of the router s local port on the same subnet as the ETEP management port see Figure 34 If the devices are on the same subnet you do not need to enter a default gateway After entering the new IP address it takes 10 20 seconds for the ETEP to set the address on the m
53. n match the settings of the equipment to which they are connected If the problem is not resolved the network may not be functioning properly Consult a local network administrator Port status LED is not blinking no traffic ETEP Installation Guide Check physical connectivity Verify that the policies are set up to allow traffic to pass through the appliance Check with your Network Administrator to ensure proper placement in the network 61 Troubleshooting Table 23 LED Indicators Power supply LED is off The power supply is unplugged or is unable to recover from a power interruption e Make sure the power cable is attached and plugged in to the power supply and the power outlet Check the status LED on the power supply on the rear of the unit If the LED is off the power supply is not receiving power If the LED is red the power supply requires a manual power cycle Unplug the power cord wait 5 seconds and then reapply power The LED is green during normal operation If a manual power cycle does not restore power contact customer support Error State Table 24 Error State Symptoms and Solutions The Alarm LED is illuminated The ETEP enters an error state when a boot test fails the operating temperature threshold is exceeded signature errors are detected on critical files pertaining to policies and keys or a FIPS test fails when the ETEP is in FIPS mode When the ETEP is in an error state the A
54. ns 37 preparation 25 rear panel diagrams ET0010A 13 ET0100A 14 15 ET1000A 18 regulatory information ET0010A 66 ETO100A 67 ET1000A 68 requirements ET0010A cables 27 ET0100A cables 35 ET1000A cables 40 safety guidelines 23 software 24 RoHS directive 65 S safety guidelines 23 self tests ET0010A 63 ET0100A ET1000A 64 serial port logging in to the CLI 47 SFTP server third party software 24 shutting down the ETEP 45 software ETEP software requirements 24 specifications ET0010A 20 ETO100A 21 ETEP Installation Guide ET1000A 22 status LEDs ET0010A self tests 63 ET0100A ET1000A self tests 64 T tamper evident seal 55 technical support 7 throughput license See also license entering 52 licensed ETEP speeds 52 traffic status LED ET0010A 12 ET0100A 15 ET1000A 17 troubleshooting diagnostic code display ET0010A 63 ET0100A ET1000A 64 error state 62 LED indicators 61 power up codes ET0010A 63 ET0100A ET1000A 64 U unpacking the shipping carton ET0010A 27 ET0100A 36 ET1000A 41 W WEEE directive 65 Z zeroization how it works 58 recovery from 59 ETEP Installation Guide Index 73 Index 74 ETEP Installation Guide Black Box Tech Support FREE Live 24 7 Tech support the way it should be A Great tech support is just 30 seconds away at 724 746 5500 or blackbox com BLACK BOX About Black Box Black Box Network Services
55. nt seal is located on the rear panel The frequency of a physical inspection depends on the value of the intellectual property being protected and the security of the environment in which the ETEP is located For example a locked equipment closet is more secure than an open server room At a minimum it is recommended that the unit s physical integrity be checked on a monthly basis AN CAUTION The ETEP does not contain any field replaceable internal parts Do not remove the unit s cover for any reason Removing the cover will zeroize the ETEP returning it to its factory default state All configuration data and keys are destroyed during the zeroization process The cover is to be removed only by authorized service personnel Unauthorized cover removal voids the product warranty AN CAUTION Disconnect all power cords before servicing ETEP Installation Guide 55 Maintenance What To Do If an Appliance Fails Most ETEP models do not contain any field replaceable parts If you experience an appliance failure contact Customer Support for a replacement ETEP and throughput license The ET1000A has field replaceable power supplies Contact Customer Support to obtain a replacement power supply in the event of a failure See Replacing the ET1000A Power Supply on page 56 for removal and installation instructions Related topics e Obtaining a License for Replacement Units on page 56 e Replacing the ET1000A Power Supply
56. oup 2 The ETEP interfaces with network equipment through two data ports the local port and the remote port Unencrypted traffic that originates from a trusted local network is received on the local port where the ETEP applies security processing to it The encrypted traffic is then sent from the remote port to an untrusted network such as the Internet At the opposite endpoint the process is reversed Encrypted traffic is received on the ETEP remote port and decrypted Then the decrypted traffic is sent from the local port to the destination The ETEP is managed in line or out of band through a dedicated Ethernet management interface The ETEP can be managed in two ways depending on the size and complexity of your deployment e Command Line Interface CLI The CLI is all you need to manage a standalone deployment typically a pair of ETEPs CLI commands are available to perform initial setup of the ETEP along with diagnostic and troubleshooting commands In Layer 2 deployments you can configure the ETEPs for operation and create Layer 2 point to point policies using the CLI commands e EncrypTight Policy and Key Manager EncrypTight is an application for managing group encryption deployments EncrypTight separates the functions of policy management key generation and distribution and policy enforcement As a result multiple ETEPs can use common keys This works for complex mesh hub and spoke and multicast networks as well as in str
57. parato ha sido expuesto a la lluvia o d El aparato parece no operar normalmente o muestra un cambio en su desempe o o e El aparato ha sido tirado o su cubierta ha sido da ada ETEP Installation Guide Index A alarm LED ET0010A 12 ET0100A 15 ET1000A 17 autoneg command 50 B battery replacement 24 booting the appliance ET0010A 34 ET0100A 38 ET1000A 43 C cables connecting the cables ET0010A 33 ET0100A 37 ET1000A 42 pinouts 59 requirements ET0010A 27 ET0100A 35 ET1000A 40 command line interface logging in 47 connectors ET0010A connectors 11 ET0100A connectors 14 ET1000A connectors 16 customer support 7 D default gateway configuration management port 48 diagnostics power up codes CEP100 XSA description 64 ETEP Installation Guide ET0010A description 63 ET0100A description 64 ET1000A description 64 diagrams ET0010A front panel connectors 11 front panel LEDs 12 rear panel connectors 13 ET0100A front panel connectors 14 front panel LEDs 14 rear panel 15 ET1000A front panel connectors 16 front panel LEDs 16 rear panel 18 E environmental compliance 65 error state 62 F failures replacing appliances 56 replacing ET1000A power supplies 56 FIPS mode operation 54 firewall ports 26 front panel diagrams ET0010A 11 12 ETO100A 14 ET1000A 16 17 initial setup auto negotiation settings 49 logging in through the serial port 47 overview 47
58. por los orificios de ventilaci n El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor El aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo descrito en el instructivo de operaci n o como se indique en el aparato ETEP Installation Guide 69 Environmental and Regulatory Information 70 12 13 14 15 16 17 18 Precauci n debe ser tomada de tal manera que la tierra fisica y la polarizaci n del equipo no sea eliminada Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atenci n a los contactos y recept culos donde salen del aparato El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante En caso de existir una antena externa deber ser localizada lejos de las lineas de energia El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilaci n Servicio por personal calificado deber ser provisto cuando a El cable de poder o el contacto ha sido da ado u b Objectos han ca do o liquido ha sido derramado dentro del aparato o El a
59. rt to Local port to Untrusted Network Trusted Network Router Switch RS 232 Port lt 10 100 Port wf PC for initial Management Management setup Network Workstation NOTE The Gigabit management and Aux1 ports are not enabled in this release Powering on the ET1000A Review the following guidelines prior to powering up the ET1000A e The ET1000A has two power supplies We recommend that you connect the power cords to separate live circuits to provide redundancy in the case of a power outage on one of the circuits e When manually cycling the power remove power on both circuits wait five seconds and then reapply power on both circuits ETEP Installation Guide 43 Installation 44 Figure 31 Dual power supplies on the ET1000A rear panel Elements of Figure 31 1 2 3 4 5 Power cord clips Status LED for power supply 2 Power receptacle for power supply 2 Power receptacle for power supply 1 Status LED for power supply 1 To power on the ET1000A 1 2 On the appliance s rear panel plug the power cords into the power receptacles for each power supply Attach the opposite end of the first power cord to a power source Attach the second power cord to a a power source on a different circuit The power supply status LED illuminates when power is applied After the power cords are plugged in secure the cords using the clips on the rear of the unit Figure 32 The power cord
60. s to perform for a typical installation are listed below ET1000A Installation Steps 1 Review the cabling requirements on page 40 1 Unpack the shipping package on page 41 2 Prepare a space for installation of the ET1000A on page 41 9 Connect the cables on page 42 4 Apply power to the ET1000A on page 43 Cabling Requirements ET1000A Table 16 outlines the standard cables used with each port on the ET1000A The connector type listed indicates only what is required to connect to the ET1000A port and may or may not be the same connector type required for the other end of the cable Some cables are supplied by Black Box and others are user supplied Table 16 ET1000A Standard Cables Power receptacles Power supply cables certified Black Box and approved for use in the country of interest RS 232 Port Shielded copper null modem Black Box cable RS 232 DB9 connector female to male Ethernet Management Port Shielded Category 5 straight Black Box RJ 45 through cable STP RJ 45 connector Ethernet Management port SFP Local and Remote Gigabit Ethernet ports Optical SFP transceivers Not applicable Port is not enabled in this release e 1000Base LX SFPs 9 125um single mode duplex fiber or simplex fiber pair 1 transmit 1 receive 1310 nm nominal wavelength LC connector OR e 1000Base SX SFPs 62 5 125um multi mode duplex fiber or simplex fiber pair 1 transmit 1 receive 85
61. sables auto negotiation on the management port Use this setting to manually configure link speed and flow control speed 100m full 10m full 100m half 10m half When auto negotiation is disabled the speed attribute specifies the link speed and duplex setting The speed defaults to 100m full flow control leu ex When auto negotiation is disabled this attribute configures the flow control setting to be on or off The flow control setting defaults to on Example The following example sets the management port IPv4 address subnet mask and gateway for the ETEP as shown in Figure 34 Auto negotiation is left at its default setting of enabled admin configure config management interface man if ip 192 168 10 10 255 255 255 0 192 168 10 1 man if exit The next example sets the management IPv4 address and subnet mask and omits the default gateway The default gateway can be omitted when the management station and the ETEP management port and are wired directly to each other on the same subnet Auto negotiation is disabled The link speed is set to 100 Mbps full duplex and flow control is turned on admin configure config management interface man if ip 192 168 10 10 255 255 255 255 man if autoneg disable 100m full on man if exit The following example sets an IPv6 address prefix length and default gateway on the management port admin configure config management interface man if gt ip6 2001 DB8 211 11
62. setting the management IP address 48 installation 71 Index ET0010A applying power 34 connecting the cables 33 rack mounting 28 table top installation 31 unpacking the shipping carton 27 ET0100A applying power 38 connecting the cables 37 rack mounting 25 unpacking the shipping carton 36 ET1000A applying power 43 cabling requirements 40 connecting the cables 42 rack mounting 41 unpacking the shipping carton 41 firewall ports 26 IP address setting on the management port 48 L LEDs ET0010A indicator description 12 ET0100A indicator description 15 ET1000A indicator description 17 troubleshooting 61 license entering 52 for replacement units 56 viewing 53 lithium battery warning 24 logging in through the serial port 47 maintenance recommendations 55 replacing appliances 56 management interface auto negotiation 49 default gateway 48 description 48 IP address 48 P packing list ET0010A 27 ET0100A 36 ET1000A 41 pinouts ET0010A 59 ET0100A ET1000A 60 72 port status ET0010A LED description 12 ET0100A LED description 15 ET1000A LED description 17 ports configuring your firewall 26 power indicator LED ET0010A 12 ETO100A 15 ET1000A 17 power supply replacing on the ET1000A 56 powering up the appliance ET0010A 34 ET0100A 38 ET1000A 43 R rack mount CEP10 602 instructions 28 ET0010A instructions 28 ET0100A ET1000A mounting instructio
63. speed 1 At the command prompt type show throughput speed Configuration Example The following example illustrates the commands used for initial setup of the ETEP to configure the following parameters management IP address subnet mask and default gateway auto negotiation date and time The autoneg command needs to be configured only if you want to disable auto negotiation and configure the link speed and flow control manually pep login admin Password admin gt configure config gt management interface man if gt ip 192 168 10 10 255 255 255 0 192 168 10 1 man if gt autoneg disable 100m full on man if gt exit config gt date 2008 10 15 12 30 00 config gt exit admin gt Managing the ETEP The ETEP can be managed in two ways depending on the size and complexity of your deployment e Command Line Interface CLI You can configure the ETEPs for operation and create Layer 2 point to point policies using the CLI commands To manage the ETEP using the CLI you can attached a PC directly to the serial port or use any SSH client for a secure remote connection through the Ethernet management port e EncrypTight Policy and Key Manager EncrypTight can distribute keys to a large number of ETEPs It works for complex mesh hub and spoke and multicast networks as well as in straightforward point to point topologies EncrypTight ETEP Installation Guide 53 Initial Setup 54 includes tools for appliance con
64. t be moved within the receptacle Figure 24 Wiggling or jostling an improperly seated power cord may cause the appliance to reboot Figure 25 Figure 24 Properly seated ET0100A power cable 1 8 inch 38 ETEP Installation Guide Installing the ET1000A Figure 25 Improperly seated ET0100A power cable When the appliance powers up all LEDs illuminate see Figure 26 The Alarm LED illuminates briefly and the diagnostic code LED displays 88 to verify that the diagnostic display segments are functioning The power LED remains lit until the unit is powered off During the boot process the ET0100A cycles through its startup tests and the corresponding diagnostic codes are displayed see Diagnostic Codes ETO100A and ET1000A on page 64 After the tests execute successfully the diagnostic code display is solidly illuminated with code 00 NOTE During the boot process the ETO100A discards all traffic on its data ports Once the appliance is operational the default mode of operation passes all packets in the clear until you deploy security policies Figure 26 ET0100A Front Panel Status Indicators Elements of Figure 26 1 Diagnostic display 2 Alarm LED 3 Power indicator Installing the ET1000A To prepare the ET1000A for installation review the installation steps in Table 15 unpack the shipping carton and prepare a space for the installation of the appliance ETEP Installation Guide 39 Table 15 The step
65. t is attached to the side of the ET1000A using four screws 3 Attach the mounting brackets to the rack s front support with the large 10 32 screws using a 2 Phillips screwdriver Insert two screws in each bracket using the top and bottom holes Figure 29 Figure 29 Front view of mounting brackets e mme O 18 8 AaA Connecting the Cables ET1000A Follow the instructions below to connect the ET1000A to the appropriate network devices see Figure 30 42 ETEP Installation Guide Installing the ET1000A To cable the ET1000A 1 For initial setup connect the RS 232 port directly to a PC or workstation using a DB 9 null modem cable This cable can be removed after initial setup is complete 2 Connect the Ethernet management port to a LAN using a Category 5 shielded twisted pair STP cable with an RJ 45 connector 3 Plug an SFP Gigabit transceiver into the ET1000A remote port If you are using an optical SFP insert the fiber cable in the SFP and connect the other end to the untrusted network typically via a router port If you are using a copper SFP use a shielded Category 5 straight through cable 4 Plug a second SFP Gigabit transceiver into the ET1000A local port If you are using an optical SFP insert the fiber cable in the SFP and connect the other end to the local device such as a server or switch If you are using a copper SFP use a shielded Category 5 straight through cable Figure 30 ET1000A Cabling Remote po
66. t is not Not applicable enabled in this release Remote and Local ports 2 Unshielded Category 5 User straight through cables UTP RJ 45 connector a The local remote and Ethernet management ports are auto sensing for polarity You can use shielded Category 5 straight through cables or crossover cables when connecting to these ports Unpacking the Shipping Carton ET0010A Remove all product components from the shipping carton and compare the contents to the packing list Keep all packaging in case it is necessary to return the unit The ETEP is packaged with the standard items listed below Additional cables country specific power cords and other accessories can be ordered separately 1 ETOO10A e Firmware and software is factory installed on the unit 2 Accessory Kit e 1 Power cable US e 1 Power supply ETEP Installation Guide 27 Installation e 1 Shielded null modem cable with an RJ 45 connector at one end and a DB 9 female connector at the opposite end 1 Unshielded Category 5 straight through cable UTP with RJ 45 connectors Rack mount kit includes 2 mounting brackets 4 large screws 10 32 and 4 small black screws The kit also includes 4 rubber feet and 4 small silver toned screws with built in washers for solid surface installations see Figure 11 e CD containing user documentation and a backup copy of the ETEP software Figure 11 Accessory screws and feet mi 90 Wi T d db X
67. tallation When installing the ETO010A on a solid surface have the following tools and materials available to attach the rubber feet to the bottom of the unit External power supply 4 rubber feet supplied in the Accessory Kit item 3 in Figure 11 4 small silver screws with built in washers supplied in the Accessory Kit item 4 in Figure 11 1 Phillips screwdriver user supplied To install the ETEP on a solid surface 1 2 Place the unit on a solid surface with the bottom panel facing up Locate the four screw holes on the bottom of the unit Figure 17 ETEP Installation Guide 31 Installation Figure 17 Screw holes for rubber feet installation on bottom of unit Model 410 032 402 Input Rated 12 54 serial mersber ABL E ULEL 3 Place one of the rubber feet over the hole and insert a screw into the opening Figure 18 Tighten the screw Figure 18 Rubber feet installed Model 410 092 402 Input Rated 12 12 54 Seist museos RDA UL UU cel 4 Repeat step 3 for the remaining feet 5 Turn the unit over so that it is resting on the rubber feet 6 Attach the external power supply to the power connector on the rear panel Figure 19 shows the ETOO10A rear panel and power supply 32 ETEP Installation Guide Installing the ETO010A Figure 19 ET0010A rear panel connector for external power supply Power cord connector Power supply cable on power supply connector on rear panel Connecting the
68. the ETEP Ethernet management port The appliance sends all packets to the specified router for forwarding to the management station or other EncrypTight components key generation server time server When the management port and workstation are on the same subnet a default gateway is not needed to route packets between the devices Figure 34 shows an example of a default gateway when the management station and ETEP are on different subnets The management station s IP address is 192 168 1 10 and the ETEP s management port IP address is 192 168 10 10 To send packets between the two devices the local port on Router 1 is specified as the default gateway 192 168 10 1 The gateway address must match the subnet of the management port Figure 34 Management Port Default Gateway 192 168 1 1 192 168 10 1 Management workstation Management port 192 168 1 10 192 168 10 10 About auto negotiation The default setting for the ETEP enables auto negotiation which negotiates the link speed duplex setting and flow control Use the autoneg command if the device that the ETEP connects to from a particular port does not support auto negotiation or flow control It is important to configure the ETEP and the other device the same way Both devices should either auto negotiate or be set manually to the same speed and duplex mode Having one device set manually and the other auto negotiate can cause problems that make the link perform slowly When
69. the branch circuit such as the use of power strips Maintenance Allow at least 19 inches 48 3 cm of clearance at the front of the rack for maintenance Use a cable management system to help keep cables organized out of the way and free from kinks or bends that degrade cable performance ETEP Installation Guide 25 Installation Firewall Ports Table 10 lists the protocols that are used by the ETEPs and the EncrypTight system Make sure that any firewalls in your system are configured to allow for the protocols that are required for your deployment standalone ETEPs used for point to point encryption or ETEPs used in an EncrypTight system Table 10 Firewall ports FTP TCP 20 Used for upgrading the software on the Yes 21 ETEP and retrieving appliance log files ICMP Ping Used to check connectivity with a device Yes IKE UDP 500 Used to establish security associations in ISAKMP IKE policies IPSec ESP IP Used in encryption policies Yes protocol 50 SFTP TCP 22 Used for secure FTP operations Yes SNMP UDP Used to send SNMP traps from the ETEPs Yes 161 162 to a management workstation SNTP UDP 123 Used for time synchronization among Yes EncrypTight components SSH TCP 22 Used to securely access the CLI on ETEPs Yes Yes Syslog UDP 514 Used to send syslog messages from the Yes ETEPS to a syslog server TLS TCP 443 A secure method of communicating Yes HTTPS management information between ETEMS
70. to file system corruption and potential appliance failure The ETEP remains in a shutdown state until the power is cycled The shutdown state is indicated with an operational code on the status diagnostic display as shown in Table 17 Table 17 Shutdown operational codes ET0010A 2 3 4 ET0100A CEP100 XSA CEP1000 ET1000A ETEP Installation Guide 45 Installation 46 You can perform a shutdown using a CLI command or ETEMS The following procedure describes the CLI command To shut down the ETEP from the CLI 1 Log in as Administrator user name admin or Ops user name ops 2 At the command prompt type shutdown After the system shutdown is complete the following message is displayed on the terminal Power cycle required to reboot appliance 3 Unplug the power cable from the back of the unit or from the power outlet Example In the following example the user logs in as admin and shuts down the ETEP pep login admin Password Last login Tue Apr 8 15 12 21 2008 on ttyS0 Welcome admin it is Tue Apr 8 15 17 57 UTC 2008 admin gt shutdown Related topic e shutdown on page 148 ETEP Installation Guide 3 Initial Setup This section includes the following topics Overview Logging In Through a Serial Link Configuring the Management Port Setting the Date and Time Entering a Throughput License Configuration Example Managing the ETEP Overview The following steps are required for initial s

Download Pdf Manuals

image

Related Search

Related Contents

  MANUALE UTENTE E INSTALLATORE IT USER AND INSTALLER  Operating Instructions Rear Projection Smart Board 3000i 1  VE-H100B - SOLIC Medical Equipment  Télécharger le document    Model 2850 Service Manual  TrueTrack™ Room Beacon Quick start guide  honestech VHS to DVD 7.0 Plus  Traceur GPS Description du produit Mise en marche  

Copyright © All rights reserved.
Failed to retrieve file