Home
BEA SBK-30R User's Manual
Contents
1. beam is aligned and unobstructed Additionally the SBK30 Interface LED also has indications of its own depending on the switch selection and SBK30 beam status 8 Company Contact Do not leave problems unresolved If a satisfactory solution cannot be achieved after troubleshooting a problem please call BEA Inc If you must wait for the following workday to call BEA leave the door inoperable until satisfactory repairs can be made Never sacri ce the safe operation of the automatic door or gate for an incomplete solution The following numbers can be called 24 hours a day 7 days a week For more information visit www beasensors com US and Canada Canada Northeast 1 866 249 7937 1 866 836 1863 1 866 836 1863 Southeast Midwest West 1 800 407 4545 1 888 308 8843 1 888 419 2564 7 Accessories Jamb Cap Kit included with SBK30 beam set May be used on sliding door applications or otherwise Rail Mount Kit included with SBK30 beam set Used on 1 75 x 0 5 barstock type guide rails InterFace Board IFB included with SBK30 beam set Converts an NPN output to a dry relay output capable of powering one SBK30 Beam pair SYMPTONS PROBABLE CAUSES CORRECTIVE ACTION No LED s visible at the back side of the beam heads No Power Check power supply Check for damaged cabling and connection points Beam output will not change state Beams are misaligned Faulty transmitter or receiver Check for yell
2. 3 Installation SBK 30 USER S GUIDE 1 Description 75 5179 05 20080415 Page 1 of 2 The SBK 30 10 1029 is a self contained infrared beam set that may be used for various applications most commonly automatic pedestrian doors The beams t easily into a pre drilled hole and are a snap t Wiring is by a quick disconnect cable that can be daisy chained up to 30 in 15 increments The beams offer an LED indication at their back side for ease of alignment and troubleshooting 1 Pre drill a hole at the desired mounting location 2 When using more than one set of beams alternate the beam orientation as shown at right 3 Route the long cable from its termination point to the beam mounting location 4 Plug the beam cable in via the snap together connector 5 Install the beam into the hole and press the beam until it clicks into the opening Typically the wall thickness of the drilled material should not exceed 1 8 PHOTOELECTRIC BEAMS FOR GUIDE RAIL APPLICATIONS Emitter A Receiver B Emitter C Receiver A Emitter B Receiver D Receiver C Emitter D Beam A Between 45 and 55 from floor Beam B C Between 6 and 12 from any other beam Beam D Between 6 and 28 from floor For sliding doors ANSI BHMA A156 10 2005 states the lowest beam should be between 6 152mm and 28 711mm from the oor The distance between the highest beam and the o
3. or should be between 45 1143mm and 55 1397mm Other beams between the lowest and highest should not be greater than 6 152mm and 12 305mm apart from any other beam EMITTER SBK 30T RECEIVER SBK 30R 2 Speci cations SBK30R SBK30T BEAM SBK30 INTERFACE MODULE TECHNOLOGY Active Infrared 880nm One SBK30 Beam Set DETECTION MODE Presence Detection N A SUPPLY VOLTAGE 10 to 30 VDC 12 to 24 VAC DC CURRENT CONSUMPTION Receiver 15mA Emitter 9mA 53 mA MAX OUTPUT CONSUMPTION NPN Output Light Operate 1 Relay NC NO Contacts 0 30 second adjustable hold time OUTPUT RATING 100 mA max Total Output Load Rated Load 0 3A 125VAC NO Contacts 0 3A 125VAC NC Contacts 1 0A 30VDC NO Contacts 1 0A 30VDC NC Contacts RANGE BEAM SEPARATION 30 feet N A OUTPUT RESPONSE TIME 1 mS 3 mS MATERIAL ABS Plastic amp Acrylic Lense PCB with shrink rube CONNECTION Molex 3 Conductor w 26 AWG Wire One Beam Pair INGRESS PROTECTION IP65 NEMA 4 IP65 NEMA 4 Enclosure OPERATING TEMPERATURE 30F to 130F 30F to 130F WIRING 8 Wire on Beam 15 Extension Cable None Included 6 Troubleshooting 5 Power ON Page 2 of 2 75 5179 05 20080415 Upon powering observe the back of the beams for LED indications There should be a green LED illuminated at the back side of the Emitter and the Receiver to indicate power ON The Receiver should also have an orange LED illuminated when the
4. ow LED at receiver to con rm alignment If an orange LED can t be obtained and green LED s are on at TX and RX replace receiver If green LED is off at TX replace TX beam head SBK30 BACK SIDE LED DISPLAY GREEN LED ON Power is applied YELLOW LED ON Beams are unobstructed OFF Beam Broken RED LED N A If using a BEA LO Linx lockout module simply plug each beam into the connection point at the module Connection points are identi ed on the LO Linx If using SBK30 beams directly be sure the NPN Light Operate output works with the door controller The chart below shows wire color designations for the SBK 30 TX RX DESCRIPTION TX EMITTER RX RECEIVER CABLE TX BEAM CABLE RX BEAM Ground Black Blue Black Blue NPN Light Operate White N A White Black 10 to 30 VDC Red Brown Red Brown Light operate means ground is provided when receiver sees emitter To wire directly to door control cut off connector on extension cable and strip jacket from wires Connect wires according to door control guidelines If the application requires a dry output the SBK 30 IFB can be used Simply plug one beam set into the IFB and wire the appropriate relay outputs NO or NC per the application SBK 30 IFB 4 Wiring SBK 30 Connection SBK 30 INTERFACE Red Black White Green Brown DESCRIPTION 12 24 VAC DC 12 24 VAC DC COM NO NC
Download Pdf Manuals
Related Search
Related Contents
M68HC705J1A IN-CIRCUIT SIMULATOR USER'S MANUAL manual 2 en singel 取扱説明書 CG431 World Marketing of America QDE1425 space heater Catalogue alternance 2014 - grasco Copyright © All rights reserved.
Failed to retrieve file