1. too warm simply adjust by adding cold water See Important Safety Instructions HIGH LIMIT The heater includes an exclusive Intelligent High Limit This safety circuit will not false trip from hot tap water It will only turn the heater off if the thermostat fails To reset simply press the red button If the high limit trips frequently call a service technician INDICATOR LIGHT The light turns on when the heater is operating PRESSURE VACUUM SWITCH The heater is equipped with a preset pressure or vacuum switch The pump must be running with water flowing in the whirlpool to allow the heater to turn on NOTE Smaller fractional horsepower pumps may not activate the heater Contact your dealer for troubleshooting procedures
2. BALB QA THE PERMAHEAT WHIRLPOOL naorer oronp BATH HEATER Your whirlpool bathtub heater has been specifically designed to enhance the enjoyment of your whirlpool bath Once filled a built in thermostat constantly maintains the warm relaxing temperature of the whirlpool bath for as long as you desire Your whirlpool bathtub heater is totally self contained to insure trouble free installation and operation Please read and follow all instructions carefully IMPORTANT SAFETY INSTRUCTIONS You should have received safety instructions with your whirlpool bathtub system Please read and follow them carefully Those instructions will include the following warnings 1 WARNING Risk of electrical shock Do not permit any electrical appliances such a light telephone radio or television within five feet of the whirlpool bath 2 DANGER To reduce the risk of injury do not remove the suction cover s from the whirlpool bath 3 To reduce the risk of injury a The water in your whirlpool should not exceed 104 Fahrenheit Lower water temperatures are recommended for extended use exceeding 10 15 minutes and are definitely recommended for younger children b Pregnant or possibly pregnant women should consult a physician before using the whirlpool Water temperatures in excess of 100 Fahrenheit are not recommended c The use of alcohol drugs or medication before or during the use of the whirlpool may lead to unconsciousness with the
3. or pressure switch may not activate the heater if water flow is inhibited To assure proper heater operation all jets may need to be fully open and the pump operated at or near maximum flow Please refer to your whirlpool bath operation manual for additional information 40568 Rev B Oct 14 2010 CAUTION e Before use of the pump and heater test the GFCI for proper operation e The pump and or heater should turn off when the GFCI Test button is pressed 30A 115V 15A 115V 15A 115V OR OR OR 20A 230V 10A 230V 10A 230V BRANCH BRANCH BRANCH CIRCUIT CIRCUIT CIRCUIT GFCI gt GFCI GFCI lt BLACK HOT gt Fi 2 lt lt WHITE COM Figure 1 lt lt GREEN GRND a 3 COND fF j j 3 COND 3 COND ct t On ED Figure 3 cI T 8 oo gt fii n ET Figure 4 opii CTT pi Y iii t y 1 Ey PRESSURE INSTALLATION Pressure _ L Figure 5 Line 2 PA g i B Vacuum r 1 Line CI E l Once the heater is installed operation is totally automatic The heater will help maintain the temperature of the water in the bathtub or increase the temperature of the water in the bathtub at about two to four degrees Fahrenheit per hour The heater includes the following components THERMOSTAT The Smart Thermostat requires no adjustment and will automatically maintain the temperature at 102 104 Fahrenheit If the bathtub is
4. possibility of drowning Consult your physician before using the whirlpool if you are using any medications d Persons suffering from obesity or with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using the whirlpool 4 WARNING Risk of child drowning To reduce the risk of accidental drowning do not permit children to use the whirlpool unless they are closely supervised ELECTRICAL INSTRUCTIONS WARNING RISK OF ELECTRICAL SHOCK All electrical connections must be accomplished by a qualified electrician in accordance with the National Electric Code and any local codes In addition a GFCI MUST protect all branch circuits to the whirlpool and every electrical component MUST be grounded 1 Route two separate branch circuits figure 1 to the junction box near the whirlpool Alternate Power Supply Route a branch circuit for both pump and heater as shown figure 2 e Each branch circuit MUST BE GFCI PROTECTED 2 Use copper conductors only 3 Insure the heater and pump are properly GROUNDED and pump is BONDED as required 4 A timer or air switch can be installed in the pump motor circuit for additional convenience There is no need to install a timer or air switch in the heater circuit as all operations are automatic NOTICE If your whirlpool bathtub is equipped with adjustable jets variable soeed pump or other flow control system the pre set vacuum

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung 32”LED-Fernseher  User Manual  Installation,Quick User Guide and Software Activiation  Gefen EXT-DVI-1600HD  Gabarito 94062  Edimax EA-OD19 Outdoor Directional Antenna  Manual  Amana 21.7 cu. ft. / 614 liter Chest Freezer Deepfreeze AFC2207AW    1. Introduction 2. Getting Start  

Copyright © All rights reserved.
Failed to retrieve file