Home
Avaya Cable User's Manual
Contents
1. re 15 ft 1 4 57 m A oun cn Pin 1 gt Pin 13 le Why o WAIT 2S Sa COCUUUUNUAY P eet a ER Pin Race Pin 25 15 position D sub plug with locking posts 25 position D sub plug with screw locks ground shield connected to backshell ground shield connected to backshell CAB0041A Industry Interface Type RS 232 C Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 7 Signal Ground Transmitted Data 2 3 Received Data Transmit Clock 4 15 Transmit Clock Data Set Ready 6 8 Data Carrier Detect Data Carrier Detect 10 4 Clear to Send Receive Clock 12 17 Receive Clock Received Data 14 2 Transmitted Data Internal Wire Connections Pint gt 7 gt 9 Pin4 gt 5 Pin6 gt 8 Pin 6 gt 20 Pin3 gt 4 gt 12 117339 A Rev A 6 23 Cable Guide V 35 Pass through 15 Pin to V 35 Order No 7219 4 Pin8 Q ANY e Pin 9 Pin 15 Pin 1 15 position D sub plug with locking posts ground shield connected to backshell Industry Interface Type V 35 V 10 and V 11 a ay T lt ov 34 position V 35 plug with screw jack retainers ground shield connected to backshell CAB0042A 6 24 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin
2. Industry Interface Type RS 232 C Pin 1 wal Oe W Ce 25 Pin 14 25 position D sub plug with screw locks ground shield connected to backshell CABO0056A Bay Networks Termination Modem Termination Signal Pin to Pin Signal Data Carrier Detect 1 8 Data Carrier Detect Transmit Data TXD 2 2 Transmit Data TXD Receive Data RXD 3 3 Receive Data RXD Data Set Ready 4 6 Data Set Ready Data Terminal Ready 6 20 Data Terminal Ready Clear to Send 7 5 Clear to Send Request to Send 8 4 Request to Send 117339 A Rev A 2 5 Cable Guide Console Modem Interface to RS 232 C Modem Order No 7825 Caution This is a modem cable Do not use this cable to attach an ASCII terminal to a Bay Networks router hardware platform Use this cable to attach a modem to any Bay Networks router hardware platform except a model BLN BLN 2 or BCN D 25 ft m 7 63 m S Pin 4 gt Pin 13 Pin 9 Pin 14 9 position D sub plug with screw locks 25 position D sub plug with screw locks ground shield connected to backshell ground shield connected to backshell CABO0060A Industry Interface Type RS 232 C Bay Networks Termination Modem Termination Signal Pin to Pin Signal Transmit Data 2 2 Tran
3. Order No AA0018021 a 15 ft _ Al 4 57 m Pin 1 Pin 8 Pin 1 yy Pin 8 EN Jo neol Jo AY rel aes NOOO Pin 9 Le are 15 Pin 9 Pin 15 15 position D sub plug with locking posts 15 position D sub plug with locking posts ground shield connected to backshell ground shield connected to backshell CAB0098A Industry Interface Type T1 DS1 Bay Networks Termination A Bay Networks Termination B Signal Pin to Pin Signal Transmit Tip 1 3 Receive Tip Transmit Ring 9 11 Receive Ring Receive Tip 3 1 Transmit Tip Receive Ring 11 9 Transmit Ring Ground 2 4 Ground Ground 2 4 Ground a You must configure onboard jumpers to complete this connection Refer to the table called QMCT1 Link Module Settings in nstalling T1 Link Modules in BN Platforms 117339 A Rev A 5 9 Cable Guide Quad MCT1 15 Pin to 15 Pin Straight through Cable Order No AA0018022 15 ft 4 57 m Pin le yy Pin 8 Pin ae ee oy Pin 8 SITET ARS PAARL Le PONLE re T AV Te Pin 9 Pin 15 Pin 9 Pin 15 15 position D sub plug with locking posts 15 position D sub plug with locking posts ground shield connected to backshell ground shield connected to backshell CAB0099A Industry Interface Type T1 DS1 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Transmit Tip 1 1 Transmit Tip Transmit Ring 9 9 Transmit Ring Receive Tip 3 3 Receiv
4. 117339 A Rev A 8 17 Numbers 50 6 66 7115 Ethernet cable 3 3 7116 15 pin to RS 422 V 25bis cable 7 3 7117 15 pin to RS 422 raise DTR cable 7 5 7118 15 pin to RS 232 raise DTR cable 7 7 7119 15 pin to RS 232 V 25bis cable 7 8 7120 15 pin to V 35 V 25bis cable 7 9 7121 15 pin to V 35 raise DTR cable 7 10 7122 44 pin to 15 pin RS 232 cable adapter 8 3 7123 44 pin to 15 pin X 21 cable adapter 8 5 7124 44 pin to 15 pin V 35 cable adapter 8 7 7125 Token Ring MAU cable 3 4 7126 Token Ring MAU cable with ferrite bead 3 5 7128 Token Ring to RJ 11 cable 3 6 7131 44 pin to 15 pin RS 422 cable adapter 8 9 7135 FDDI FSD to FSD cable 3 7 7136 FDDI FSD to straight tip cable 3 7 7137 44 pin to V 35 raise DTR cable 7 11 7138 44 pin to RS 232 raise DTR cable 7 13 7139 44 pin to RS 422 raise DTR cable 7 15 7150 MCT1 clock cable 5 11 7151 MCT1 15 pin loopback connector 5 12 7152 MCT1 RJ 48 loopback connector 5 13 7153 MCT1 crossover cable 5 14 7154 MCT1 RJ 48 loopback cable 5 15 7155 MCT1 15 pin loopback cable 5 16 7156 MCT1 RJ 48 straight through cable 5 17 117339 A Rev A Index 7157 MCT1 15 pin straight through cable 5 18 7158 15 pin to male V 35 cable 6 17 7159 44 pin to male V 35 cable 6 18 7160 MCE1 crossover cable 5 19 7161 MCE1 straight through cable 5 20 7162 MCE1 coaxial cable 5 21 7163 FDDI SC duplex to SC du
5. 3 10 117339 A Rev A Chapter 4 HSSI Cables This chapter identifies the High Speed Serial Interface HSSI cables that link Bay Networks router hardware platforms to LAN and WAN devices Table 4 1 summarizes the cables Detailed cable illustrations and pinouts follow Table 4 1 HSSI Cables Order No Length Physical Cable Description Page 7830 10 ft 3 05 m HSSI DCE plug to DTE plug 4 3 7831 50 ft 15 24m HSSI DCE plug to DTE plug 4 3 7832 20 ft 6 10 m HSSI crossover HSSI plug to HSSI plug 4 5 This cable is intended for test environments only If you need to order additional cables contact the Bay Networks Technical Solutions Center in your area See How to Get Help in the front matter 117339 A Rev A 4 1 Cable Guide The following sections include Cable illustrations with the Bay Networks connector on the left and the remote connector on the right Cable length information If you want to build your own cables and you want to determine the maximum cable length appropriate for each of your interconnection requirements you should Identify in this chapter a cable that satisfies your wiring requirement with the exception of total cable length Consult the HSSI specification for cable length data Pinouts for each connector and all associated signals Grounding arrangements that isolate the chassis from the DC ground within the cable 4 2 117339 A Rev
6. Pin 46 gt 47 gt 48 117339 A Rev A 6 57 Cable Guide 50 Pin to 44 Pin Crossover Order No 7940 15 ft 4 57 m Pin 1 lt b ae 25 il En a 50 position 0 8 mm plug ground shield connected to internal shell Pin 26 Pin 50 Industry Interface Type V 35 V 10 and V 11 aE Pin 15 5y y E COUT TUT UU UU AZ Pin 16 TR UA A a TV EOP aae N Pin 44 Pin 30 44 position D sub plug with screw locks ground shield connected to backshell CABO0078A 6 58 117339 A Rev A Standard Synchronous Cables Bay Networks Termination A Bay Networks Termination B Signal Pin to Pin Signal VSD 44 37 VRD VSD 19 35 VRD VRD 43 38 VSD VRD 18 36 VSD Request to Send 4 9 Data Carrier Detect Data Carrier Detect 9 4 Request to Send VRT 42 40 VTT VTT 45 34 VRT VRT 17 39 VTT VTT 20 33 VRT Signal Ground 7 7 Signal Ground Internal Wire Connections Pin 4 gt 5 CTS Pin 4 gt 5 CTS Pin 41 VST gt 45 VTT Pin 32 VST gt 40 VTT Pin 16 VST gt 20 VTT Pin 31 VST gt 39 VTT Pin 7 gt 30 gt 31 gt 34 Pin 7 gt 19 gt 20 gt 23 Pin 13 gt 38 Pin 13 gt 28 Pin 14 gt 39 Pin 14 gt 29 Pin 46 gt 47 gt 48 Pin 41
7. Cable Guide Part No 117339 A Rev A September 1997 Bay Networks Bay Networks 4401 Great America Parkway 8 Federal Street Santa Clara CA 95054 Billerica MA 01821 Copyright 1997 Bay Networks Inc All rights reserved Printed in the USA September 1997 The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is proprietary to Bay Networks Inc Trademarks ACE AFN AN BCN BLN BN BNX CN FN FRE GAME LN Optivity PPX and Bay Networks are registered trademarks and Advanced Remote Node ANH ARN ASN BayeSIS BayStack BayStream BCNX BLNX EZ Install EZ Internetwork EZ LAN IP AutoLearn PathMan Quick2Config RouterMan SN SPEX Switch Node System 5000 Bay Networks Press and the Bay Networks logo are trademarks of Bay Networks Inc Microsoft MS MS DOS Win32 Windows and Windows NT are registered trademarks of Microsoft Corporation All other trademarks and registered trademarks are the property of their respective owners Statement of Conditions In the interest of improving internal design operational function and or reliability Bay Networks Inc reserves the right
8. OO oo9g 34 position V 35 receptacle with screw jack retainers ground shield connected to backshell CAB0084A Industry Interface Type V 35 V 10 and V 11 6 66 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal VSD 44 R Receive Data A VSD 19 T Receive Data B VRD 43 P Send Data A VRD 18 S Send Data B Request to Send 4 F Data Carrier Detect Data Carrier Detect 9 D Clear to Send VTT 45 Y Send Timing A VTT 20 AA Send Timing B Frame Ground A Frame Ground Signal Ground 7 B Signal Ground Internal Wire Connections Pin4 gt 5 PinC gt D Pin 41 gt 42 gt 45 Pin V gt Y Pin 16 gt 17 gt 20 Pin X gt AA Pin 13 gt 38 PinE gt F Pin 14 gt 39 Pin 7 gt 30 gt 31 gt 34 gt 46 gt 47 117339 A Rev A 6 67 Chapter 7 Dialup Services Cables This chapter identifies dialup services cables necessary for linking Bay Networks router hardware platforms to WAN dial on demand and dial backup devices Note Order Nos 7220 7318 7826 7932 7943 and 7937 support V 25 bis Table 7 1 summarizes the cables Detailed cable illustrations and pinout specifications follow Table 7 1 Dialup Services Cables Raise Order No Length Physical Cable Description DTR V 25bis Page 7116 15 ft 4 57 m 15
9. ground shield connected to backshell CAB0010A Industry Interface Type X 21 Caution You cannot use this cable adapter to provide a clock master to an attached service This is a passive straight through cable 117339 A Rev A 8 5 Cable Guide Bay Networks Termination Termination to Existing Cable Signal Pin to Pin Signal Send Data 2 2 Send Data Send Data 16 3 Send Data Receive Data 3 14 Receive Data Receive Data 17 13 Receive Data Data Carrier Detect 9 10 Data Carrier Detect Data Carrier Detect 23 9 Data Carrier Detect Request to Send 4 6 Request to Send Request to Send 18 15 Request to Send Send Timing 10 4 Timing Send Timing 24 5 Timing Signal Ground 7 1 Signal Ground Internal Wire Connections Pin 7 gt 19 gt 20 gt 23 Pin1 gt 7 gt 9 Pin 28 gt 30 Pin 4 gt 12 Pin 14 gt 15 Pin5 gt 11 Pin 41 gt 43 8 6 117339 A Rev A Cable Adapters 44 Pin to 15 Pin V 35 Cable Adapter Order No 7124 Note This adapter enables you to connect an existing 15 pin V 35 cable Order No 7215 or 7216 to a 44 pin port This cable assembly automatically selects the V 35 interface RING s Pin 1 Pin 1 EE pin ts eet LES S Pnn eaa Pin 16 A Gia HY 7 Pin 30 Pin 15 S ng Ie H MAAN Pin 3
10. to Pin Signal Transmit Data 2 3 Receive Data Receive Data 3 2 Transmit Data Request to Send 4 5 Clear to Send Clear to Send 5 4 Request to Send Signal Ground 7 7 Signal Ground Internal Wire Connections Pin 6 gt 20 117339 A Rev A 2 3 Cable Guide AFN AN Console Interface to ASCII Terminal Order No 7526 Caution Do not use this cable to attach a modem to any Bay Networks router hardware platform Use this cable only to attach an ASCII terminal to a Bay Networks model AN or AFN platform 25 ft 7 63 m as oo eeN ex Dam j gpe0000000000 Pin 9 Pin 25 _ Pin 14 9 position D sub plug with screw locks 25 position D sub receptacle with screw locks ground shield connected to backshell ground shield connected to backshell CAB0055A Industry Interface Type RS 232 C Bay Networks Termination Remote Termination Signal Pin to Pin Signal Transmit Data 2 3 Receive Data Transmit Data Receive Data 2 5 Clear to Send 4 7 Request to Send Clear to Send Request to Send NIAJ AJO Signal Ground Signal Ground Internal Wire Connections Pin 6 gt 8 gt 20 2 4 117339 A Rev A Console Modem Cables AT Serial Console Order No 7527 Pin 5 i a Pint oj oOo000 ooo S qel 9 position D sub receptacle with screw locks ground shield connected to backshell
11. 7832 HSSI crossover cable 4 5 7833 RS 232 synchronous pass through cable 6 39 7834 44 pin to V 35 pass through cable 6 1 7835 V 35 44 pin to 44 pin crossover cable 6 42 7836 V 35 44 pin to 15 pin crossover cable 6 44 7837 44 pin synchronous to V 28 cable 6 46 7932 50 pin to V 35 cable 6 48 7933 50 pin to V 35 raise DTR cable 7 17 7934 50 pin to RS 232 cable 6 50 7935 50 pin to RS 232 raise DTR cable 7 19 7936 50 pin to X 21 cable 6 51 7937 50 pin to RS 422 cable 6 52 7938 50 pin to 50 pin crossover cable 6 54 7939 50 pin to 15 pin crossover cable 6 56 7940 50 pin to 44 pin crossover cable 6 58 Index 2 7941 15 pin to F RS 232 synchronous pass through cable 6 60 7942 15 pin to F V 35 synchronous pass through cable 6 61 7943 44 pin to F RS 232 synchronous pass through cable 6 62 7944 44 pin to F V 35 synchronous pass through cable 6 63 7945 50 pin to F RS 232 synchronous pass through cable 6 65 7946 50 pin to F V 35 synchronous pass through cable 6 66 7947 50 pin to 44 pin V 35 cable adapter 8 11 7948 50 pin to 15 pin V 35 cable adapter 8 14 A AA0018001 MCE1 DB9 to mod jack cable 5 4 AA0018002 MCE1 DB9 to unterminated cable 5 5 AA0018003 15 pin to F X 21 synchronous pass through cable 6 4 AA0018004 44 pin to F X 21 synchronous pass through cable 6 6 AA0018005 50 pin to X 21 synchronous pass through cable 6 1 AA0018006 Quad MCT1 clock cab
12. Cable Basics Table 1 2 Cables Listed by Order Number continued Order No Physical Cable Description Page 7826 44 pin D sub plug to RS 232 plug leased line or V 25bis for WAN connection 6 38 7830 HSSI DCE plug to DTE plug 10 ft 4 3 7831 HSSI DCE plug to DTE plug 50 ft 4 3 7832 HSSI crossover cable HSSI plug to HSSI plug 4 5 7833 RS 232 synchronous pass through 44 pin plug to RS 232 plug 6 39 7834 V 35 synchronous pass through 44 pin plug to V 35 plug 6 40 7835 V 35 crossover cable 44 pin plug to 44 pin plug 6 42 7836 V 35 crossover cable 44 pin plug to 15 pin plug 6 44 7837 44 pin to V 28 plug for WAN connection 6 46 7932 50 pin to V 35 plug 6 48 7933 50 pin to V 35 with raise DTR 7 17 7934 50 pin to RS 232 6 50 7935 50 pin to RS 232 C with raise DTR 7 19 7936 50 pin to X 21 6 51 7937 50 pin to RS 422 6 52 7938 50 pin to 50 pin crossover 6 54 7939 50 pin to 15 pin crossover 6 56 7940 50 pin to 44 pin crossover 6 58 7941 15 pin to female RS 232 C synchronous pass through 6 60 7942 15 pin to female V 35 synchronous pass through 6 61 7943 44 pin to female RS 232 C synchronous pass through 6 62 7944 44 pin to female V 35 synchronous pass through 6 63 7945 50 pin to female RS 232 C synchronous pass through 6 65 7946 50 pin to female V 35 synchronous pass through 6 66 7947 50 pin to 44 pin cable adapter 8 11 7948 50 pin to 15 pi
13. OEP Ie We Yoder No TIJA opion aea EEA ES 6 48 50 Pin to RS 232 Order No 7934 sresrasrdsni nann ER iaue caverns eines 6 50 50 Pin to X 21 Order No 7936 a a ARS EET aneian EiS 6 51 BOP itt th RS ee Oe No TIST siiri 6 52 50 Pin to 50 Pin Crossover Order No 7938 ccciccectsssiesccsneinnciaaetisge uate edeneesteneee 6 54 50 Pin to 15 Pin Crossover Order No 7939 nesens PEEP EE TE 6 56 50 Pin to 44 Pin Crossover Order No 7940 esssssssessssssssssssssssrsssrnssrnossnnsssnnssnnsssns 6 58 15 Pin to F RS 232 Synchronous Pass through larder NO TOAT Y srednica aaa a e n oae Dia aa aE EE 6 60 15 Pin to F V 35 Synchronous Pass through Order No 7942 s sssssesssesssesssessssn 6 61 44 Pin to F RS 232 Synchronous Pass through der Na TIAS eard E tuamectuald dei 6 62 44 Pin to F V 35 Synchronous Pass through Order No 7944 ee PE eee 6 63 50 Pin to F RS 232 Synchronous Pass through PACD ING PIED wire A A E E E E N EO ET 6 65 50 Pin to F V 35 Synchronous Pass through Order No 7946 sesser 6 66 Chapter 7 Dialup Services Cables 15 Pin D Sub to RS 422 V 25bis Order No 7116 0 E PEE PE 7 3 15 Pin D Sub to RS 422 Raise DTR Order No 7117 secsrcrsnsirsnicnniareninienes 7 5 15 Pin D Sub to RS 282 Raise DTR Order No 118 iriri iasciisdsraiinn rianan sundar 7 7 15 Pin D Sub to RS 292 V2SbIs Order No 7119 ccsssedsccstsaevececsawrnetinnrsdiacrseaetianscsuete 7 8 15 Pin D Sub to V35 V 25bis Order No 7120 csc
14. Send Data 2 14 Receive Data Send Data 3 13 Receive Data Serial Clock Transmit 4 12 Serial Clock Receive Serial Clock Transmit 5 11 Serial Clock Receive Request to Send 6 10 Data Carrier Detect Data Carrier Detect 10 6 Request to Send Serial Clock Receive 11 5 Serial Clock Transmit Serial Clock Receive 12 4 Serial Clock Transmit Receive Data 13 3 Send Data Receive Data 14 2 Send Data Return Common 15 1 Signal Ground Internal Wire Connections Pin6 gt 8 Pin6 gt 8 Pin7 gt 9 gt 15 Pin7 gt 9 gt 15 117339 A Rev A 6 33 Cable Guide 15 Pin D Sub to RS 422 Order No 7315 15 ft 4 57 m aey Ping aye re i Pin 9 LI 15 position D sub plug with locking posts ground shield connected to backshell Pin 1 lt Pin 20 Industry Interface Type RS 449 RS 422 Pin 37 37 position D sub plug with screw locks ground shield connected to backshell CAB0050A 6 34 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 25 Send Common Send Data 2 4 Send Data A Send Data 3 22 Send Data B Serial Clock Transmit 4 5 Send Timing A Serial Clock Transmit 5 23 Send Timing B Request to Send 6 12 Terminal Ready A Clear to Send 7 27 Clear to Send B Clear to S
15. Shield Pin 3 Shield grounded to backshell 5 20 117339 A Rev A E1 T1 Cables MCE1 Coaxial Cable Order No 7162 Twist lock Twist lock coaxial connector coaxial connector CABO0034A Industry Interface Type E1 G 703 117339 A Rev A 5 21 Cable Guide MCE1 DB9 to DB15 Straight through Cable Order No 7167 Note This cable provides a direct connection to a 15 pin D sub port eo 10 ft 3 05 m al ave 9 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type E1 G 703 Pin 1 A enw fh Pin 8 a AAAS o poe n ge 15 position D sub plug with locking posts ground shield connected to backshell CAB0095B Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive A 1 3 Receive A Receive B 6 11 Receive B Transmit A 5 1 Transmit A Transmit B 9 9 Transmit B Internal Wire Connections Pin 3 gt Shield 5 22 117339 A Rev A E1 T1 Cables MCE1 DB9 to DB15 Crossover Cable Order No 7168 Note This cable provides a crossover connection to a 15 pin D sub port 10 ft S S 3 05 m a fo zeae Pin 1 Pin 8 i TUN e Jo AAT aa VUI Pin 9 ee UI Pin 15 Pin 9 9 position D sub plug with screw locks 15 position D sub plug with locking posts ground shield connected to backshell ground
16. 1 544 MB ESF framing format 04DU9 1SN 1 544 MB ESF framing format with B8ZF coding 04DU9 1ZN 1 544 MB ANSI ESF and ZBTSI without line power The telephone company will select the code it has available The Service Order Code s SOC 6 0Y The required Universal Service Order Code USOC jack RJ48C e When you request ISDN U Interface Service you must provide the telephone company with The Facility Interface Code 021S5 The Service Order Code s SOC 6 0F The required Universal Service Order Code USOC jack RJ49C e When you request ISDN S T Interface Service you must provide the telephone company with The Service Order Code s SOC 6 0P The make model number and FCC Registration number of the NT1 Note ISDN S T cannot be directly connected to the network e When you request Primary Rate ISDN Service you must provide the telephone company with The Facility Interface Code 04DU9 1SN 1 544 MB ESF framing format with B8ZF coding The Service Order Code s SOC 6 0Y The required Universal Service Order Code USOC jack RJ48C Your telephone company may make changes to its facilities equipment operations or procedures that could affect the proper functioning of your equipment The telephone company will notify you in advance of such changes to give you an opportunity to maintain uninterrupted telephone service If the unit causes harm to the telephone network the telephone comp
17. 2 4 Grounda a You must configure onboard jumpers to complete this connection Refer to the table called QMCT1 Link Module Settings in Installing T1 Link Modules in BN Platforms 5 6 117339 A Rev A E1 T1 Cables MCE1 RJ 45 to RJ 45 Cable Order No AA0018014 Note This cable assembly uses a 120 ohm wire Tt Pin 8 Pin 1 gt m RJ 45 connector Industry Interface Type E1 10 ft 3 05 m Pin 8 F Pin 1 Si RJ 45 connector CAB0026C Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive Tip 1 1 Receive Tip Receive Ring 2 2 Receive Ring Transmit Tip 4 4 Transmit Tip Transmit Ring 5 5 Transmit Ring 117339 A Rev A 5 7 Cable Guide MCE1 RJ 45 to Unterminated Cable Order No AA0018015 Note This cable assembly uses a 120 ohm wire m 10 ft m __ i ST RJ 45 connector Industry Interface Type E1 3 05 m Unterminated cable CABO0097A Bay Networks Termination Transmit Ring Signal Pin Signal Receive Tip 1 Transmit Tip Receive Ring 7 Transmit Ring Transmit Tip 5 Transmit Tip Transmit Ring 5 8 117339 A Rev A E1 T1 Cables Quad MCT1 15 Pin to 15 Pin Crossover Cable
18. 9 pin to 9 pin 5 19 MCT1 15 pin to 15 pin multichannel 5 9 15 pin to RJ 48 5 14 v 35 44 pin to 15 pin 6 44 44 pin to 44 pin 6 42 custom cables 1 11 customer support programs XXV Technical Solutions Centers xxvi dialup services cables 15 pin to RS 232 raise DTR 7 7 15 pin to RS 232 V 25bis 7 8 15 pin to RS 422 raise DTR 7 5 15 pin to RS 422 V 25bis 7 3 15 pin to V 35 raise DTR 7 10 15 pin to V 35 V 25bis 7 9 44 pin to RS 232 raise DTR 7 13 44 pin to RS 422 raise DTR 7 15 44 pin to V 35 raise DTR 7 11 connectors x i s MCT1 loopback 50 pin to RS 232 raise DTR 7 19 15 pin 5 12 50 pin to V 35 raise DTR 7 17 RJ 48 5 13 listed 7 1 terminology 1 8 DSX 5 1 types 1 9 DTE to DCE connector defined 1 9 examples diagram 1 10 dust covers fiber optic connector 1 9 117339 A Rev A Index 3 E El cables listed 5 1 Ethernet cable 3 3 F FC connector defined 1 9 FDDI cables 3 7 to 3 9 fiber optic connector dust cover 1 9 finding cables by category 1 3 industry interface type 1 12 order number 1 4 fixed shroud duplex FSD connector defined 1 9 H how to use this guide 1 2 HSSI cables crossover 4 5 DCE to DTE 10 ft and 50 ft 4 3 listed 4 1 industry interface type defined 1 12 E1 5 4 5 5 5 7 5 8 E1 G 703 5 19 to 5 23 Ethernet 802 3 3 3 High Speed Serial Interface HSSI 4 3 4 5 RS 232 C 2 3 2 4 2 5 2 6 2 7 6 23
19. Connections Pin 7 gt 30 gt 31 gt 34 Pin 13 gt 38 Pin 14 gt 39 117339 A Rev A 7 19 Chapter 8 Cable Adapters This chapter identifies the cable adapters that enable existing cables to connect to different ports These cable assemblies automatically select the appropriate interface type Table 8 1 summarizes the cable adapters Detailed cable illustrations and pinouts follow Table 8 1 Console Modem Cables Order No Length Physical Cable Description Page 7122 12 in 0 3 m 44 pin to 15 pin RS 232 cable adapter 8 3 7123 12 in 0 3 m 44 pin to 15 pin X 21 cable adapter 8 5 7124 12 in 0 3 m 44 pin to 15 pin V 35 cable adapter of 7131 12 in 0 3 m 44 pin to 15 pin RS 422 cable adapter 8 9 7947 12 in 0 3 m 50 pin to 44 pin cable adapter 8 11 7948 12 in 0 3 m 50 pin to 15 pin V 35 cable adapter 8 14 AA0018024 12 in 0 3 m 50 pin to 15 pin RS 422 cable adapter 8 16 If you need to order additional cables contact the Bay Networks Technical Solutions Center in your area See How to Get Help in the front matter 117339 A Rev A 8 1 Cable Guide The following sections include e Cable illustrations with the Bay Networks connector on the left and the remote connector on the right e Cable length information If you want to build a cable and you want to determine the maximum cable length appropriate for that interconnection
20. Data Signal B Serial Clock Transmit 4 Y Serial Clock Transmit Signal A Serial Clock Transmit 5 AA Serial Clock Transmit Signal B Request to Send 6 C Request to Send Clear to Send 8 D Clear to Send Data Carrier Detect 10 F Data Carrier Detect Serial Clock Receive 11 X Serial Clock Receive Signal B Serial Clock Receive 12 V Serial Clock Receive Signal A Receive Data 13 iy Receive Data Signal B Receive Data 14 R Receive Data Signal A Internal Wire Connections Pin1 gt 7 PinC gt H 117339 A Rev A 6 17 Cable Guide 44 Pin to V 35M Order No 7159 o 10 ft 3 05 piny Pin 15 SRST Pin 16 S amp A 009 AAN a Pin30 I ASAAN Pin 31 dLa 44 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type V 35 V 10 and V 11 lt scwvrmo gt AA 34 position V 35 plug with screw jack retainers ground shield connected to backshell CABO0031B 6 18 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Frame Ground 1 A Frame Ground Request to Send 4 C Request to Send Clear to Send 5 D Clear to Send Data Set Ready 6 E Data Set Ready Data Terminal Ready 8 H Data Terminal Ready Data Carrier Detect 9 F Data Carrier Detect VTT 40 U Ter
21. Pin 16 VST gt 20 VTT Pin 16 VST gt 20 VTT Pin 7 gt 30 gt 31 gt 34 Pin 7 gt 30 gt 31 gt 34 Pin 13 gt 38 Pin 13 gt 38 Pin 14 gt 39 Pin 14 gt 39 Pin 46 gt 47 gt 48 Pin 46 gt 47 gt 48 117339 A Rev A 6 55 Cable Guide 50 Pin to 15 Pin Crossover Order No 7939 1s a oo oi 4 57 m Pin De AMATO Pin 8 Pin 1 Pin 25 Jo TEIAS pesca EET NS g a Pin 9 Pin 15 Pin 50 50 position 0 8 mm plug 15 position D sub plug with locking posts ground shield connected to internal shell ground shield connected to backshell CABO0077A Yg Pin 26 Industry Interface Type V 35 V10 and V 11 6 56 117339 A Rev A Standard Synchronous Cables Bay Networks Termination A Bay Networks Termination B Signal Pin to Pin Signal VSD 44 14 Receive Data VSD 19 13 Receive Data VRD 43 2 Send Data VRD 18 3 Send Data Request to Send 4 10 Data Carrier Detect Data Carrier Detect 9 6 Request to Send VRT 42 4 SCT VTT 45 12 SCR VRT 17 5 SCT VTT 20 11 SCR Signal Ground 7 1 Signal Ground Internal Wire Connections Pin 4 gt 5 CTS Pin 6 gt 8 CTS Pin 41 VST gt 45 VTT Pint gt 7 gt 9 gt 15 Pin 16 VST gt 20 VTT Pin 7 gt 30 gt 31 gt 34 Pin 13 gt 38 Pin 14 gt 39
22. PinE gt F Pin 14 gt 29 Pin 7 gt 19 gt 20 gt 23 gt 41 gt 42 6 64 117339 A Rev A Standard Synchronous Cables 50 Pin to F RS 232 Synchronous Pass through Order No 7945 15 ft 4 57 m ae een Pin 13 T r A ds Z Later eliminates o Pin 26 p en 50 Pin 25 i a Pin 14 50 position 0 8 mm plug ground shield connected to internal shell 25 position D sub receptacle with screw locks ground shield connected to backshell A CAB0083A Industry Interface Type RS 232 C Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send Data 2 3 Receive Data Receive Data 3 2 Send Data Request to Send 4 8 Data Carrier Detect Data Carrier Detect 9 4 Request to Send Send Timing 10 15 Send Timing Frame Ground 1 1 Frame Ground Signal Ground 7 7 Signal Ground Internal Wire Connections Pin4 gt 5 Pin4 gt 5 Pin 10 gt 11 gt 12 Pin 15 gt 17 Pin 13 gt 38 Pin 6 gt 20 Pin 14 gt 39 Pin 7 gt 30 gt 31 gt 34 117339 A Rev A 6 65 Cable Guide 50 Pin to F V 35 Synchronous Pass through Order No 7946 _ L O Pin 26 n E 50 50 position 0 8 mm plug ground shield connected to internal shell gt s lt nNVIMIOS OOOGO0 O OOMOO Fi x lt 4 0m0 W
23. Token Ring MAU Cable Order No 7125 ee Pin S fo ani o Pin 9 AEZ Red E 9 position D sub plug with screw locks G ap a ground shield connected to backshell reen Black Orange Data connector CAB0012A Industry Interface Type Token Ring 802 5 Bay Networks Termination Token Ring MAU Signal Pin Contact by Wire Color ReceiveA 1 Reas Transmit A 5 Black Receive B 6 Green Transmit B 9 Orange 3 4 117339 A Rev A LAN Cables Token Ring MAU Cable with Ferrite Bead Order No 7126 Pin 1 Sea Pin 9 9 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type Token Ring 802 5 L m Ferrite Bead Fair ite Part Bo T 0443167251 fmt or equivalent Green Black Orange Data connector CABO0013A Bay Networks Termination Token Ring MAU Signal Pin Contact by Wire Color Receive A 1 Red Transmit A 5 Black Receive B 6 Green Transmit B 9 Orange 117339 A Rev A 3 5 Cable Guide Token Ring to RJ 11 Cable Order No 7128 12 in 0 3 m Pin 1 A haan a eee T 8 Pin 9 9 position D sub plug with screw locks RJ 11 compatible socket ground shield connected to backshell CABO014A Industry Interface Type Token Ring 802 5 B
24. Type V 35 V 10 and V 11 7 008 Q lt x lt 4 0m0 D an LECOVIMOP gt 34 position V 35 plug with screw jack retainers ground shield connected to backshell CABO0070A 6 48 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal VSD 44 P Send Data A VSD 19 S Send Data B VRT 42 V Receive Timing A VRT 17 X Receive Timing B VST 41 Y Send Timing A VST 16 AA Send Timing B VRD 43 R Receive Data A VRD 18 T Receive Data B Data Set Ready E Data Set Ready Data Terminal Ready H Data Terminal Ready Request to Send C Request to Send Clear to Send 5 D Clear to Send VTT 45 U Terminal Timing A VTT 20 W Terminal Timing B Frame Ground A Frame Ground Data Carrier Detect 9 F Data Carrier Detect Signal Ground 30 B Signal Ground Internal Wire Connections Pin 7 gt 30 gt 31 gt 34 Pin 46 gt 47 gt 48 Pin 13 gt 38 Pin 14 gt 39 117339 A Rev A 6 49 Cable Guide 50 Pin to RS 232 Order No 7934 15 ft 4 57 m n Pin 1 de B Pim 2 Pin 13 ie RAPER o Pin 26 ae 50 Pin a Pin 25 rana iad omea e aeei Pa pormo ab plod gi aera iee CAB0073A Industry Interface Type RS 232 C Bay Networks T
25. comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help 117339 A Rev A jii European Requirements Only EN 55 022 Statement This is to certify that the Bay Networks lt product or system name gt is shielded against the generation of radio interference in accordance with the application of Council Directive 89 336 EEC Article 4a Conformity is declared by the application of EN 55 022 Class A CISPR 22 Warning This is a Class A product In a domestic environment this product may c
26. du Canada indique que I appareillage est certifi c est dire qu il respecte certaines exigences de s curit et de fonctionnement visant les r seaux de t l communications Le minist re ne garantit pas que l appareillage fonctionnera la satisfaction de l utilisateur Avant d installer l appareillage s assurer qu il peut tre branch aux installations du service de t l communications local L appareillage doit aussi tre raccord selon des m thodes accept es Dans certains cas le c blage interne du service de t l communications utilis pour une ligne individuelle peut tre allong au moyen d un connecteur certifi prolongateur t l phonique Le client doit toutefois prendre note qu une telle installation n assure pas un service parfait en tout temps Les r parations de l appareillage certifi devraient tre confi es un service d sign par le fournisseur En cas de r paration ou de modification effectu es par l utilisateur ou de mauvais fonctionnement de I appareillage le service de t l communications peut demander le d branchement de appareillage Pour leur propre s curit les utilisateurs devraient s assurer que les mises la terre des lignes de distribution d lectricit des lignes t l phoniques et de la tuyauterie m tallique interne sont raccord es ensemble Cette mesure de s curit est particuli rement importante en milieu rural Attention Les utilisate
27. pin D sub plug to RS 422 plug V T3 7117 15 ft 4 57 m 15 pin D sub plug to RS 422 plug y 7 5 7118 15 ft 4 57 m 15 pin D sub plug to RS 232 plug V 7 7 7119 15 ft 4 57 m 15 pin D sub plug to RS 232 plug V 7 8 7120 15 ft 4 57 m 15 pin D sub plug to V 35 plug V 7 9 7121 15 ft 4 57 m 15 pin D sub plug to V 35 plug V 7 10 7137 15 ft 4 57 m 44 pin D sub plug to V 35 plug V 7 11 7138 15 ft 4 57 m 44 pin D sub plug to RS 232 plug y 713 7139 15 ft 4 57 m 44 pin D sub plug to RS 422 plug V 15 7933 15 ft 4 57 m 50 pin to V 35 with raise DTR y 7 17 7935 15 ft 4 57 m 50 pin to RS 232 with raise DTR V JAD 117339 A Rev A 7 1 Cable Guide If you need to order additional cables contact the Bay Networks Technical Solutions Center in your area See How to Get Help in the front matter The following sections include Illustrations for each cable with the Bay Networks connector on the left and the remote connector on the right Cable length information If you want to build a cable and you want to determine the maximum cable length appropriate for each of your interconnection requirements you should Identify in this chapter a cable that satisfies your wiring requirement with the exception of total cable length Consult the networking industry specification standard or recommendation designated in the Industry Interface Type entry for that cable located immediately following the cable
28. pinout diagram Pinouts for each connector and all associated signals Wire jumper identification for either connector when applicable For example the 15 pin D sub to RS 422 cable Order No 7116 lists internal wire connections Pin 7 gt 12 Pin 25 gt 30 in the Remote Termination column This indicates that you must connect pin 7 to pin 12 and pin 25 to pin 30 inside the remote connector Grounding arrangements that isolate the chassis from the DC ground within the cable 7 2 117339 A Rev A Dialup Services Cables 15 Pin D Sub to RS 422 V 25bis Order No 7116 15 position D sub plug with locking posts ground shield connected to backshell Industry Interface Type RS 449 RS 422 TEES Pin 1 L Pin 19 COCT TUT UU UY ene Pin 20 Pin 37 37 position D sub plug with screw locks ground shield connected to backshell CAB0003A 117339 A Rev A 7 3 Cable Guide Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 37 Send Ground Send Data 2 4 Send Data A Send Data 3 22 Send Data B Serial Clock Transmit 4 5 Send Timing A Serial Clock Transmit 5 23 Send Timing B Request to Send 6 7 Request to Send A Clear to Send 7 27 Clear to Send B Clear to Send 8 9 Clear to Send A Data Carrier Detect 9 29 Data Mode B Data Carrier Detec
29. plug to V 35 plug raise DTR for Series 7 software 7 10 7122 44 pin to 15 pin RS 232 C cable adapter 8 3 7123 44 pin to 15 pin X 21 cable adapter 8 5 7124 44 pin to 15 pin V 35 cable adapter 8 7 continued 1 4 117339 A Rev A Cable Basics Table 1 2 Cables Listed by Order Number continued Order No Physical Cable Description Page 7125 9 pin D sub plug to Token Ring 802 5 MAU data connector no ferrite bead STP 3 4 cable 7126 9 pin D sub plug to Token Ring 802 5 MAU data connector with ferrite bead STP 3 5 cable 7128 9 pin D sub plug to Token Ring 802 5 RJ 11 receptacle 3 6 7131 44 pin to 15 pin RS 422 cable adapter 8 9 7135 FDDI X3T9 5 FSD to FSD multimode fiber cable dual attachment to FDDI ring af requires two cables 7136 FDDI FSD to bayonet ST connectors multimode fiber cable dual attachment to 3 7 FDDI ring requires two cables 7137 44 pin D sub plug to V 35 plug raise DTR for Series 7 software LAL 7138 44 pin D sub plug to RS 232 Cplug raise DTR for Series 7 software 7 13 7139 44 pin D sub plug to RS 422 plug raise DTR for Series 7 software 7 15 7150 MCT1 clock cable 9 pin D sub plug to 15 pin D sub plug 5 11 7151 MCT1 loopback plug 15 pin D sub plug 5 12 7152 MCT1 loopback plug RJ 48 5 13 7153 MCT1 crossover cable 15 pin D sub plug to RJ 48 5 14 7154 MCT1 loopback cable RJ 48 to RJ 48 5 15 7155 MCT1 loopback cable 15 pin D sub
30. products are licensed for use under the terms of the applicable Bay Networks Inc Software License Agreement that accompanies such software and upon payment by the end user of the applicable license fees for such software 2 Restrictions on use reservation of rights The Software and user manuals are protected under copyright laws Bay Networks and or its licensors retain all title and ownership in both the Software and user manuals including any revisions made by Bay Networks or its licensors The copyright notice must be reproduced and included with any copy of any portion of the Software or user manuals Licensee may not modify translate decompile disassemble use for any competitive analysis reverse engineer distribute or create derivative works from the Software or user manuals or any copy in whole or in part Except as expressly provided in this Agreement Licensee may not copy or transfer the Software or user manuals in whole or in part The Software and user manuals embody Bay Networks and its licensors confidential and proprietary intellectual property Licensee shall not sublicense assign or otherwise disclose to any third party the Software or any information about the operation design performance or implementation of the Software and user manuals that is confidential to Bay Networks and its licensors however Licensee may grant permission to its consultants subcontractors and agents to use the Software at Licensee s fac
31. the connector at one end of a cable a termination can be either a plug or receptacle type connector 1 8 117339 A Rev A Cable Basics Connector Types Bay Networks provides the following connector types Attachment Unit Interface AUI A 15 pin D type connector that connects equipment to the Ethernet network through a transceiver CCITT Series V 28 V 35 CCITT recommended V 10 unbalanced and V 11 balanced standard connectors DTE to DCE interface X 21 CCITT recommended DTE to DCE synchronous public switched network connector Fiber Channel FC Threaded straight tip coaxial or fiber optic connectors Fixed shroud duplex FSD Jack type dual fiber optic connector for use in FDDI networks Media access unit multistation access unit MAU LAN wiring concentrator used in token ring networks Recommended Standard RS 232 C RS 449 RS 422 EIA standard connectors for use with DTE and DCE devices Registered Jack Series RJ 45 RJ 48 8 position FCC registered data plugs Subscriber Connector SC duplex Jack type dual fiber optic connector for use in FDDI networks Spade terminals Flat U shaped connectors typically used for T carrier line connection Straight tip ST Bayonet coaxial or fiber optic connectors Note Many types of fiber optic connectors include a dust cover Dust obstructs or attenuates optical signals entering or leaving the cable through the connector Be careful not to
32. to V 35 plug leased line or V 25bis for WAN connection 6 26 7221 15 pin D sub plug to X 21 plug for WAN connection 6 28 7224 44 pin D sub plug to X 21 plug for WAN connection 6 29 7255 15 pin D sub plug to RS 232 Cplug for WAN connection 6 30 7256 15 pin D sub plug to V 28 plug for WAN connection 6 31 7260 15 pin to 15 pin synchronous crossover for back to back node operation 6 32 7315 15 pin D sub plug to RS 422 plug for WAN connection 6 34 7318 44 pin D sub plug to RS 422 plug leased line or V 25bis for WAN connection 6 36 7401 15 pin T1 Framer plug labeled DSX 1 or DSX 2 to 15 pin DTE plug for CSU 5 24 connection 7415 15 pin T1 Framer plug labeled DSX 1 or DSX 2 to 15 pin Customer Premise 5 25 Equipment CPE plug 7525 25 pin D sub plug to RS 232 C receptacle for console interface to ASCII terminal 2 3 connection 7526 AFN AN console cable 9 pin D sub plug to RS 232 C receptacle for console 2 4 interface to ASCII terminal connection 7527 9 pin D sub plug to RS 232 C receptacle for console modem connection to a 25 console using a modem cable and a null modem adapter 7650 15 position CSU network receptacle to RJ 45 for T carrier line connection 5 26 7750 15 position CSU network receptacle to spade terminals for T carrier line 5 27 connection 7825 9 pin D sub plug to RS 232 C modem plug for console modem interface to dial 2 6 modem connection continued 1 6 117339 A Rev A
33. 1 8 Receive Timing A Receive Timing 25 26 Receive Timing B Send Timing 10 5 Send Timing A Send Timing 24 23 Send Timing B Receive Data 3 6 Receive Data A Receive Data 17 24 Receive Data B Clear to Send 19 27 Clear to Send B Clear to Send 5 Clear to Send A Request to Send 4 Request to Send A Request to Send 18 25 Request to Send B Data Set Ready 6 11 DMA Data Set Ready 20 29 DM B Terminal Ready 8 12 Terminal Ready A Terminal Ready 22 30 Terminal Ready B Terminal Timing 12 17 Terminal Timing A Terminal Timing 26 35 Terminal Timing B Send Common 44 37 Send Common Signal Ground 41 19 Signal Ground Internal Wire Connections Pin 41 gt 43 Pin 20 gt 37 Pin 13 gt 28 Pin 14 gt 29 117339 A Rev A 6 37 Cable Guide 44 Pin D Sub to RS 232 Leased Line or V 25bis Order No 7826 Pin 1 al Pin 15 DAS nnn Ac Pin 16 I lt b PARRA A AN 7 9 Pin 30 Pin 31 Se Pin 44 44 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type RS 232 C Pin 13 Pin 14 eet E 25 25 position D sub plug with screw locks ground shield connected to backshell CABO0069A Bay Networks Termination Remote Termination Signal Pin to Pin Signal Frame Ground 1 1 Frame Ground Send Dat
34. 1 AS PERNT af Ys 5 position D sub receptacle with slide latch 44 position D sub plug with screw locks connected to backshell ground shield connected to backshell CAB0010A Industry Interface Type V 35 Caution You cannot use this cable adapter to provide a clock master to an attached service This is a passive straight through cable 117339 A Rev A 8 7 Cable Guide Bay Networks Termination Termination to Existing Cable Signal Pin to Pin Signal VRD 37 14 Receive Data VRD 35 13 Receive Data VSD 38 2 Send Data VSD 36 3 Send Data Data Carrier Detect 10 Data Carrier Detect Request to Send 4 6 Request to Send Clear to Send 8 Clear to Send Data Set Ready 15 Data Set Ready VRT 34 12 Receive Timing VRT 33 11 Receive Timing VST 32 4 Send Timing VST 31 Send Timing Signal Ground 19 1 Signal Ground Internal Wire Connections Pin 7 gt 19 gt 20 gt 23 Pin1 gt 7 gt 9 Pin 13 gt 28 Pin 14 gt 29 Pin 41 gt 42 gt 43 8 8 117339 A Rev A Cable Adapters 44 Pin to 15 Pin RS 422 Cable Adapter Order No 7131 Note This adapter enables you to connect an existing 15 pin RS 422 cable Order No 7315 or AA0018011 to a 44 pin port This cable assembly automatically selects the RS 422 interface RING s Pin 1 P
35. 14 gt 29 117339 A Rev A 6 41 Cable Guide V 35 Crossover 44 Pin to 44 Pin Order No 7835 Note This crossover cable interconnects two Bay Networks router software platforms F 15 ft Aaa Pin 1 arn Fal Pin15 Pini w i ro Pin 15 te TERR Tal pin so pin tela CUTE T E HOHA gt i MS ea Pin 31 lt e 3 Pin 44 Pin31 pin 44 44 position D sub plug with screw locks 44 position D sub plug with screw locks ground shield connected to backshell ground shield connected to backshell CABO0067A Industry Interface Type V 35 V 10 and V 11 6 42 117339 A Rev A Standard Synchronous Cables Bay Networks Termination A Bay Networks Termination B Signal Pin to Pin Signal VSD 38 37 VRD VSD 36 35 VRD VRD 37 38 VSD VRD 35 36 VSD RTS 4 9 DCD DCD 4 RTS VRT 34 40 VTT VTT 40 34 VRT VRT 33 39 VTT VTT 39 33 VRT Signal Ground 7 7 Signal Ground Internal Wire Connections Pin 4 gt 5 CTS Pin 4 gt 5 CTS Pin 32 VST gt 40 VTT Pin 32 VST gt 40 VTT Pin 31 VST gt 39 VTT Pin 31 VST gt 39 VTT Pin 7 gt 19 gt 20 gt 23 Pin 7 gt 19 gt 20 gt 23 Pin 13 gt 28 Pin 13 gt 28 Pin 14 gt 29 Pin 14
36. 35 a Pin 8 Pin 1 SSS Pin 1 Pin 25 00000000 ae EER CAAAAAAOOOOOONAUNNANNNANN peas Pin 26 pin 50 Gigs Ping 50 position WAN plug 15 position D sub receptacle with slide latch connected to backshell CAB0086A Industry Interface Type V 35 Caution You cannot use this cable adapter to provide a clock master to an attached service This is a passive straight through cable 8 14 117339 A Rev A Cable Adapters Bay Networks Termination Termination to Existing Cable Signal Pin to Pin Signal V 35 Receive Data 43 14 Receive Data V 35 Receive Data 18 13 Receive Data V 35 Send Data 44 2 Send Data V 35 Send Data 19 3 Send Data Data Carrier Detect 9 10 Data Carrier Detect Request to Send 4 6 Request to Send Clear to Send 5 8 Clear to Send Data Set Ready 6 15 Data Set Ready V RT 42 12 Receive Timing VRT 17 11 Receive Timing VRT 14 4 Send Timing VRT 16 5 Send Timing Signal Ground 7 1 Signal Ground Internal Wire Connections Pin 7 gt 30 gt 31 gt 34 Pint gt 7 gt 9 Pin 13 gt 38 Pin 14 gt 39 Pin 46 gt 47 gt 48 117339 A Rev A 8 15 Cable Guide 50 Pin to 15 Pin RS 422 Cable Adapter Order No AA0018024 Note This adapter cable allows you to connect an existing 1
37. 35 Loopback CKT A Send Data 11 11 Send Data Send Data 36 36 Send Data Loopback CKT B 12 12 Loopback CKT B Loopback CKT B 37 37 Loopback CKT B Signal Ground 13 13 Signal Ground Signal Ground 38 38 Signal Ground Signal 14 14 Signal Signal Ground 19 19 Signal Ground Signal Ground 44 44 Signal Ground Signal Ground 25 25 Signal Ground Signal Ground 50 50 Signal Ground 4 4 117339 A Rev A HSSI Cables HSSI Crossover Order No 7832 a eS Pin 1 Pin25 Pini Pin 25 Tg ERR i EEE CREE CUE Pin 26 SU pinso Pin 26 Z pin 50 50 position high density plug 50 position high density plug ground shield connected to internal shell ground shield connected to internal shell CAB0064A Industry Interface Type High Speed Serial Interface HSSI This cable is intended solely for test environments you cannot use it in production applications Within such test environments this cable provides a proprietary nonstandard back to back connection of Bay Networks router hardware platforms through their HSSI ports without intervening digital service unit DSU equipment When using the Bay Networks HSSI crossover cable you must set the HSSI interfaces to clock internally The data rate under internal clocking conditions must not exceed 25 megabits per second Mb s HSSI operation in a production
38. 5 pin RS 422 cable Order No 7315 to a 50 pin port The RS 422 interface is automatically selected Pint lt Pin 25 Tiara COCUOOOOOOOO OLAX Pin 26 Z in 50 50 position WAN plug Industry Interface Type RS 422 a hoob aah Pin 15 SS i 15 position D sub receptacle with slide latch connected to backshell Pin 8 Rg Pin 1 CAB0086A Caution You cannot use this cable adapter to provide a clock master to an attached service This is a passive straight through cable 8 16 117339 A Rev A Cable Adapters Bay Networks Termination Termination to Existing Cable Signal Pin to Pin Signal Send Data 2 2 Send Data Send Data 27 3 Send Data Receive Data 3 14 Receive Data Receive Data 28 13 Receive Data Request to Send 4 6 Request to Send Request to Send 29 15 Request to Send Clear to Send 5 Clear to Send Clear to Send 30 Clear to Send Data Carrier Detect 9 10 Data Carrier Detect Data Carrier Detect 34 9 Data Carrier Detect Send Timing 10 4 Serial Clock Transmit Send Timing 35 5 Serial Clock Transmit Receive Timing 11 12 Serial Clock Receive Receive Timing 36 11 Serial Clock Receive Signal Ground 7 1 Signal Ground Internal Wire Connections Pin 13 gt 38 Pin 14 gt 39 Pin 46 gt 48
39. 561 988 7661 561 988 7550 Information about customer service is also available on the World Wide Web at support baynetworks com 117339 A Rev A XXV Cable Guide How to Get Help If you purchased a service contract for your Bay Networks product from a distributor or authorized reseller contact the technical support staff for that distributor or reseller for assistance If you purchased a Bay Networks service program call one of the following Bay Networks Technical Solutions Centers Technical Solutions Center Telephone number Fax number Billerica MA 800 2LANWAN 508 916 3514 Santa Clara CA 800 2LANWAN 408 495 1188 Valbonne France 33 4 92 96 69 68 33 4 92 96 69 98 Sydney Australia 61 2 9927 8800 61 2 9927 881 1 Tokyo Japan 81 3 5402 0180 81 3 5402 0173 Xxvi 117339 A Rev A Chapter 1 Cable Basics This guide provides all the information you need to find a specific cable for your Bay Networks router hardware platform This chapter explains e What you need to know e How to use this guide How to find cables by category How to find cables by order number or description e Some basics about cable connectors including Connector terminology Basic connector types e How to build your own cables If you want to build a cable to meet special requirements this guide also provides pinout information and referenc
40. 6 30 6 38 6 39 6 50 6 60 6 62 6 65 7 7 7 8 7 13 7 19 8 3 RS 422 8 9 8 14 8 16 RS 449 RS 422 6 34 6 36 6 52 7 3 7 5 7 15 RS 530 6 10 6 12 6 14 TI DS1 5 9 5 10 5 14 to 5 18 5 24 to 5 27 with external clock 5 6 5 11 Index 4 token ring 802 5 3 4 to 3 6 V 28 V 10 6 16 6 31 6 46 V 35 6 32 8 7 8 11 V 35 V 10 and V 11 6 17 to 6 22 6 24 6 26 6 40 6 42 6 44 6 48 6 54 6 56 6 58 6 61 6 63 6 66 7 9 7 10 7 11 7 17 X 21 6 4 6 6 6 8 8 5 X 21 V 11 6 28 6 29 6 51 X3T9 5 PMD FDDI 3 7 to 3 10 industry standards specifications and recommendations 1 11 interface defined 1 8 L local area network LAN cables Ethernet 3 3 FDDI 3 7 to 3 9 listed 3 1 Token Ring 3 4 to 3 6 loopback cables MCT1 15 pin 5 16 RJ 48 5 15 loopback connectors MCT1 15 pin 5 12 RJ 48 5 13 117339 A Rev A MCE cables coaxial 5 21 crossover 9 pin to 9 pin 5 19 DB9 to DB15 5 23 DB9 to mod jack 5 4 DB9 to unterminated 5 5 RJ 45 to RJ 45 5 7 RJ 45 to unterminated 5 8 straight through 9 pin to 9 pin 5 20 DB9 to DB15 5 22 MCT 5 1 MCT 1 cables 15 pin to 15 pin and 9 pin Y cable 5 6 clock 5 11 crossover 15 pin to 15 pin 5 9 15 pin to RJ 48 5 14 loopback 15 pin connectors 5 16 RJ 48 connectors 5 15 straight through 5 10 15 pin 5 18 RJ 48 5 17 MCT1 loopback connectors 15 pin 5 12 RJ 48 5 13 media access unit MAU defined 1 9 modem cable B
41. 7 15 ft 4 57 m 50 pin to RS 422 6 52 7938 15 ft 4 57 m 50 pin to 50 pin crossover 6 54 7939 15 ft 4 57 m 50 pin to 15 pin crossover 6 56 7940 15 ft 4 57 m 50 pin to 44 pin crossover 6 58 7941 15 ft 4 57 m 15 pin to female RS 232 synchronous pass through 6 60 7942 15 ft 4 57 m 15 pin to female V 35 synchronous pass through 6 61 continued 6 2 117339 A Rev A Standard Synchronous Cables Table 6 1 Standard Synchronous Cables continued Order No Length Physical Cable Description Page 7943 15 ft 4 57 m 44 pin to female RS 232 synchronous pass through 6 62 7944 15 ft 4 57 m 44 pin to female V 35 synchronous pass through 6 63 7945 15 ft 4 57 m 50 pin to female RS 232 synchronous pass through 6 65 7946 15 ft 4 57 m 50 pin to female V 35 synchronous pass through 6 66 If you need to order additional cables contact the Bay Networks Technical Solutions Center in your area See How to Get Help in the front matter The following sections include Cable illustrations with the Bay Networks connector on the left and the remote connector on the right Cable length information If you want to build a cable and you want to determine the maximum cable length appropriate for each of your interconnection requirements you should Identify in this chapter a cable that satisfies your wiring requirement with the exception of total cable length Consult the networking ind
42. 7 7 Signal Ground Internal Wire Connections Pin4 gt 5 Pin4 gt 5 Pin 10 gt 11 gt 12 Pin 15 gt 17 Pin 7 gt 19 gt 20 gt 23 Pin 6 gt 20 Pin 13 gt 28 Pin 14 gt 29 117339 A Rev A 6 39 Cable Guide V 35 Pass through 44 Pin to V 35 Order No 7834 Pin 1 SS L Pin 15 DST aa Pin 16 apy Fin VL PEC EU EU UU pna E An 44 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type V 35 V 10 and V 11 lt x lt x lt HADTNOW Q OOO z opose 6 t FR gt Scwnurmo3 gt S D 34 position V 35 plug with screw jack retainers ground shield connected to backshell CAB0106A 6 40 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal VSD 38 R Receive Data A VSD 36 T Receive Data B VRD 37 P Send Data A VRD 35 S Send Data B Request to Send F Data Carrier Detect Data Carrier Detect D Clear to Send VTT 40 V Receive Timing A VTT 39 X Receive Timing B Frame Ground 1 A Frame Ground Signal Ground 7 B Signal Ground Internal Wire Connections Pin4 gt 5 PinC gt D Pin 32 gt 34 gt 40 Pin V gt Y Pin 31 gt 33 gt 39 Pin X gt AA Pin 7 gt 19 gt 20 gt 23 gt 41 gt 42 Pin E gt H Pin 13 gt 28 Pin
43. A HSSI Cables HSSI DCE to DTE 10 Ft Order No 7830 50 Ft Order No 7831 jk 10or50ft 3 05 or 15 24 m fe Pint lt SS Pin25 Pint Pin 25 EEN I EEN I Pin 26 Z pin 50 Pin 26 Z pin 50 50 position high density plug 50 position high density plug ground shield connected to internal shell ground shield connected to internal shell CABO0063A Industry Interface Type High Speed Serial Interface HSSI Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 1 Signal Ground Signal Ground 26 26 Signal Ground Receive Timing 2 2 Receive Timing Receive Timing 27 27 Receive Timing DCE Available 3 3 DCE Available DCE Available 28 28 DCE Available Received Data 4 4 Received Data Received Data 29 29 Received Data Send Timing 6 6 Send Timing Send Timing 31 31 Send Timing Signal Ground 7 7 Signal Ground Signal Ground 32 32 Signal Ground DTE Available 8 8 DTE Available continued 117339 A Rev A 4 3 Cable Guide Bay Networks Termination Remote Termination Signal Pin to Pin Signal DTE Available 33 33 DTE Available Terminal Timing 9 9 Terminal Timing Terminal Timing 34 34 Terminal Timing Loopback CKT A 10 10 Loopback CKT A Loopback CKT A 35
44. AIVER OF THE TERMS OF THIS AGREEMENT xii 117339 A Rev A Contents About This Guide O75 CECT amp eeeee ener enea Rtn eae reer cesar mtr crernr et terete time renee tierra ecranttry Canary ee reeee tre Coernn erent Te xxiv AGONYMS gacctssasciceseauids E E E E E E E T xxiv Ordering Bay Networks PUDIGSUONS smssiiirsssensnsisniia ipni anna annainn A XXV Bay Networks Customer Sendo aissius inadina aaa an kiada OVERENA AE XXV Fow io Get HEI oranin aae E L xxvi Chapter 1 Cable Basics Before You Begin PA E EE dieeatnenudeneeeenide E EE S 1 2 How io Use This GUIO ja nssnsiasanlissnien iann a 1 2 Finding Cables Uy CAE OOIY acco seniaddnexacin aaan EANN SEA EANES REESI AERE 1 3 Finding Cables by Order Number or Description cc ccesceeeeeeeeeeeeeeeeeeeeeetaeeesenes 1 4 Gablo Comedor Base cssc Ea 1 8 Gannector Dea snenia d dA P 1 8 Conigcto PES sssini aa naa a a A ei apaan 1 9 Buking MIP OWM ISS aiius aiaa ka kaaa RNAAR 1 11 Chapter 2 Console Modem Cables Console Interface to ASCII Terminal Order No 7525 ccccecsseeeeeeeeseeeseeeeeeesaeeeteneees 2 3 AFN AN Console Interface to ASCII Terminal Order No 7526 ssceeeeee deupatneas 2 4 AT Serial Console Order NG POOF bie tiassnceiaiconnctescstanieactecebanteinicaasie dermmricscncbiagaGacaaace 2 5 Console Modem Interface to RS 232 C Modem nS OS PRG E a A E E E E E TE E E T 2 6 Backbone Console Interface to RS 232 C Modem Order No 77850 cccsccscsecrseases A
45. B8ZF coding 04DU9 1ZN 1 544 MB ANSI ESF and ZBTSI without line power The telephone company will select the code it has available The Service Order Code s SOC 6 0F The required Universal Service Order Code USOC jack RJ48C e When you request 56K 64K Service you must provide the telephone company with The Facility Interface Code 04DU5 56 64 The Service Order Code s SOC 6 0F The required Universal Service Order Code USOC jack RJ48S e When you request V 34 Service you must provide the telephone company with The required Universal Service Order Code USOC jack RJ11C The make model number Ringer Equivalence Number REN and FCC Registration number of the unit The REN helps you determine the number of devices you can connect to your telephone line and still have all of those devices ring when your number is called In most but not all areas the sum of the RENs of all devices should not exceed 5 0 To be certain of the number of devices you can connect to your line you should call your local telephone company to determine the maximum REN for your calling area e When you request ISDN U Interface Service you must provide the telephone company with The Facility Interface Code 021S5 The Service Order Code s SOC 6 0F The required Universal Service Order Code USOC jack RJ49C e When you request ISDN S T Interface Service you must provide the telephone company with The Serv
46. CE A Receive Timing 11 9 Receiver Signal Element Timing DCE B Signal Ground 1 7 Signal Ground Note You must move Jumpers B and C to the X 21 2 3 position to support this interface 117339 A Rev A Cable Guide 44 Pin to RS 530 Straight through Order No AA0018012 D 15 ft Pr 4 57 m i i SHU Spee Pin 13 Pin 1 e al Pin 15 Th HAVANA Pin 16 La Vy AAAAR AAA Hall pinks ex NAILS W SJOU Pin 31 pe 44 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type RS 530 SSS Pin 14 Pin 25 25 position D sub plug with screw locks ground shield connected to backshell CABO0094A Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send Data 2 2 Transmitted Data A Send Data 16 14 Transmitted Data B Receive Data 3 3 Receive Data A Receive Data 17 16 Receive Data B Request to Send 4 4 Request to Send A Request to Send 18 19 Request to Send B Clear to Send 5 5 Clear to Send A Clear to Send 19 13 Clear to Send B Data Set Ready 6 6 DCE Ready A Data Set Ready 20 22 DCE Ready B Data Terminal Ready 8 20 DTE Ready A Data Terminal Ready 22 23 DTE Ready B Data Carrier Detect 9 8 Receive Line Signal Detect A Data Carrier Detect 23 10 Receive Line Signal Detect B S
47. Description Page AA0018001 MCE1 DB9 to mod jack cable 9 pin to RJ 45 5 4 AA0018002 MCE1 DB9 to unterminated end cable 9 pin to unterminated end 5 5 AA0018003 X 21 synchronous pass through 15 pin plug to X 21 receptacle 6 4 AA0018004 X 21 synchronous pass through 44 pin plug to X 21 receptacle 6 6 AA0018005 X 21 synchronous pass through 50 pin plug to X 21 receptacle 6 8 AA0018006 Quad MCT1 clock cable 5 6 AA0018011 RS 530 straight through cable 15 pin to RS 530 plug 6 10 AA0018012 RS 530 straight through cable 44 pin to RS 530 plug 6 12 AA0018013 RS 530 straight through cable 50 pin to RS 530 plug 6 14 AA0018014 MCE1 RJ 45 to RJ 45 5 7 AA0018015 MCE1 RJ 45 to unterminated end cable 5 8 AA0018021 Quad MCT1 crossover cable 15 pin D sub plug to 15 pin D sub plug 5 9 AA0018022 Quad MCT1 straight through cable 15 pin D sub plug to 15 pin D sub plug 5 10 AA0018023 50 pin to V 28 cable 6 16 AA0018024 50 pin to 15 pin RS 422 cable adapter 8 16 7115 15 pin Ethernet 802 3 AUI plug to 15 position Ethernet 802 3 AUI receptacle 3 3 7116 15 pin D sub plug to RS 422 plug V 25bis for Series 7 software 7 3 7117 15 pin D sub plug to RS 422 plug raise DTR for Series 7 software 7 5 7118 15 pin D sub plug to RS 232 C plug raise DTR for Series 7 software 7 7 7119 15 pin D sub plug to RS 232 C plug V 25bis for Series 7 software 7 8 7120 15 pin D sub plug to V 35 plug V 25bis for Series 7 software 7 9 7121 15 pin D sub
48. EEE Institute of Electrical and Electronic Engineers LAN local area network MAU media access unit multistation access unit PMD Physical Medium Dependent SC Subscriber Connector STP shielded twisted pair WAN wide area network XXiV 117339 A Rev A About This Guide Ordering Bay Networks Publications To purchase additional copies of this document or other Bay Networks publications order by part number from Bay Networks Press at the following numbers e Phone U S Canada 888 422 9773 e Phone International 510 490 4752 e FAX U S Canada and International 510 498 2609 The Bay Networks Press catalog is available on the World Wide Web at support baynetworks com Library GenMisc Bay Networks publications are available on the World Wide Web at support baynetworks com Library tpubs Bay Networks Customer Service You can purchase a support contract from your Bay Networks distributor or authorized reseller or directly from Bay Networks Services For information about or to purchase a Bay Networks service contract either call your local Bay Networks field sales office or one of the following numbers Region Telephone number Fax number United States and 800 2LANWAN then enter Express 508 916 3514 Canada Routing Code ERC 290 when prompted to purchase or renew a service contract 508 916 8880 direct Europe 33 4 92 96 69 66 33 4 92 96 69 96 Asia Pacific 61 2 9927 8888 61 2 9927 8899 Latin America
49. EN IF BAY NETWORKS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN NO EVENT SHALL THE LIABILITY OF BAY NETWORKS RELATING TO THE SOFTWARE OR THIS AGREEMENT EXCEED THE PRICE PAID TO BAY NETWORKS FOR THE SOFTWARE LICENSE 5 Government Licensees This provision applies to all Software and documentation acquired directly or indirectly by or on behalf of the United States Government The Software and documentation are commercial products licensed on the open market at market prices and were developed entirely at private expense and without the use of any U S Government funds The license to the U S Government is granted only with restricted rights and use duplication or disclosure by the U S Government is subject to the restrictions set forth in subparagraph c 1 of the Commercial Computer Software Restricted Rights clause of FAR 52 227 19 and the limitations set out in this license for civilian agencies and subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause of DFARS 252 227 7013 for agencies of the Department of Defense or their successors whichever is applicable 6 Use of Software in the European Community This provision applies to all Software acquired for use within the European Community If Licensee uses the Software within a country in the European Community the Software Directive enacted by the Council of European Communities Directive dated 14 May 1991 will apply to the examination of the Sof
50. LN BLN 2 and BCN platforms only 2 7 for all except BLN BLN 2 and BCN platforms 2 6 listed 2 1 multistation access unit MAU defined 1 9 P pass through cables 15 pin to female RS 232 6 60 15 pin to female V 35 6 61 117339 A Rev A 15 pin to female X 21 5 1 15 pin to RS 232 6 23 15 pin to V 35 6 24 15 pin to X 21 6 4 44 pin to female RS 232 6 62 44 pin to female V 35 6 63 44 pin to RS 232 6 39 44 pin to X 21 6 6 50 pin to female RS 232 6 65 50 pin to female V 35 6 66 50 pin to X 21 6 8 physical interface 1 8 pins defined 1 8 plug defined 1 8 publications ordering xxv R receptacle defined 1 8 recommended series RS defined 1 9 registered jack RJ defined 1 9 RS 422 cables 15 pin to 6 34 44 pin to 6 36 50 pin to 6 52 RS 530 cable 15 pin to 6 10 44 pin to 6 12 50 pin to 6 14 S SC duplex connector defined 1 9 sockets defined 1 8 software considerations choice of cable 1 2 spade terminals defined 1 9 special requirements 1 1 specifications cable 1 11 standard synchronous cables 15 pin to RS 232 6 30 Index 5 15 pin to RS 422 6 34 15 pin to V 28 6 31 15 pin to V 35 6 20 15 pin to V 35 with DTR 6 22 15 pin to X 21 6 28 44 pin to RS 232 6 38 44 pin to RS 422 6 36 44 pin to V 28 6 46 44 pin to V 35 6 26 44 pin to X 21 6 29 50 pin to V 28 6 16 listed 6 1 to 6 3 V 35 44 pin to 15 pin crossover 6 44 V 35 44
51. N A E aden chen E A 2 7 Chapter 3 LAN Cables Ethernet Cable Order No 7115 sisscisscsadestictesicceneatensiseranaace arruin audae are bisa 3 3 117339 A Rev A xiii Token Ring MAU Cable Order No 7125 c cccceseccsceeeeceeeeeceseeeeeeaeeceeseeseeseaeeneseaeeees 3 4 Token Ring MAU Cable with Ferrite Bead Order No 7126 cceecceeeseeeeeteeeeeneeeeeees 3 5 Token Ring t RJ 11 Gable Order No 2128 srssiiircnsricnisnyin i 3 6 FDDI FSD te FSD Order No 7S5 eussasiiosiah ionian aa enliamiieratetrata teenies 3 7 FDDI FSD to Straight Tip Order No 7136 A NRR e 3 7 FDDI type SC Duplex to Straight Tip Order No 7164 for Single Mode Cable cccceceeeeeeeee cece eeeeeeeeseaeeeeeeeeeseeeeeeaaeeees 3 8 FDDI type SC Duplex to SC Duplex Order No 7163 for Multimode Cable Order No 7165 for Single Mode Cable sssrini 3 9 ATM Cable SC to Straight Tip MMF Order No 7169 eeeseeeeeceeeeeeeeseeeeeeeeaaeeeee 3 10 Chapter 4 HSSI Cables HSSI DCE to DTE 10 Ft Order No 7830 50 Ft Order No 7831 secheneias EE ET EE ET 4 3 HSI Crossover Order No 7032 csscesieccctacedctcdasardaceleuseieiccahdaee sets tnnncace tomneaccaraboeeesaeetaand 4 5 Chapter 5 E1 T1 Cables MCE1 DB9 to Mod Jack Cable Order No AA0018001 eseese 5 4 MCE1 DB9 to Unterminated Cable Order No AA0018002 cceeeeeeeeseeeeeteeeeeneeeees 5 5 Quad MCT1 Cable Order No AA001 8006 e ce eee
52. Ready 6 11 Data Mode A Data Set Ready 31 29 Data Mode B Terminal Ready 8 12 Terminal Ready A Terminal Ready 33 30 Terminal Ready B Terminal Timing 12 17 Terminal Timing A Terminal Timing 37 35 Terminal Timing B Send Common 49 37 Send Common Signal Ground 48 19 Signal Ground Internal Wire Connections Pin 46 UNBE gt 48 SGRD Pin 20 gt 37 Pin 13 gt 38 Pin 14 gt 39 117339 A Rev A 6 53 Cable Guide 50 Pin to 50 Pin Crossover Order No 7938 15 ft 4 57 m o Pin 1 o 25 Pin 1 cel 25 7a EE Pin 26 Pin 50 Pin 26 50 position 0 8 mm plug 50 position 0 8 mm plug ground shield connected to internal shell ground shield connected to internal shell Pin 50 CAB0076A Industry Interface Type V 35 V 10 and V 11 6 54 117339 A Rev A Standard Synchronous Cables Bay Networks Termination A Bay Networks Termination B Signal Pin to Pin Signal VSD 44 43 VRD VSD 19 18 VRD VRD 43 44 VSD VRD 18 19 VSD Request to Send 4 9 Data Carrier Detect Data Carrier Detect 9 4 Request to Send VRT 42 45 VTT VTT 45 42 VRT VRT 17 20 VTT VTT 20 17 VRT Signal Ground 7 7 Signal Ground Internal Wire Connections Pin 4 gt 5 CTS Pin 4 gt 5 CTS Pin 41 VST gt 45 VTT Pin 41 VST gt 45 VTT
53. Ready 8 12 Data Terminal Ready A Terminal Ready 22 30 Data Terminal Ready B Data Carrier Detect 9 15 Ring Indicator Send Timing 10 5 Send Timing A Send Timing 24 23 Send Timing B Receive Timing 11 8 Receive Timing A Receive Timing 25 26 Receive Timing B Terminal Timing 12 17 Terminal Timing A Terminal Timing 26 35 Terminal Timing B Send Common 44 37 Send Common Signal Ground 41 19 Signal Ground Internal Wire Connections Pin 13 gt 28 Pin 14 gt 29 Pin 23 gt 41 gt 43 117339 A Rev A Dialup Services Cables 50 Pin to V 35 with Raise DTR Order No 7933 Ee 15 ft 4 57 m Pin 1 S gt 25 F D EEE NS Pin 26 Pin 50 50 position 0 8 mm plug ground shield connected to internal shell lt scnvrmo gt AA 34 position V 35 plug with screw jack retainers ground shield connected to backshell CABO071A Industry Interface Type V 35 V 10 and V 11 117339 A Rev A 7 17 Cable Guide Bay Networks Termination Remote Termination Signal Pin to Pin Signal VSD 44 P Send Data A VSD 19 S Send Data B VRT 42 V Receive Timing A VRT 17 X Receive Timing B VST 41 Y Send Timing A VST 16 AA Send Timing B VRD 43 R Receive Data A VRD 18 T Receive Data B Data Set Ready E Data Set Ready Data Terminal Ready H Data Terminal Ready Request t
54. Serial Clock Receive 12 8 Receive Timing A Receive Data 13 24 Receive Data B Receive Data 14 6 Receive Data A Request to Send 15 25 Request to Send B Internal Wire Connections Pin1 gt 9 Pin 7 gt 12 Terminal Ready A Pin 25 gt 30 gt 37 Note You must move Jumpers B and C to the X 21 2 3 position to support this interface 7 6 117339 A Rev A Dialup Services Cables 15 Pin D Sub to RS 232 Raise DTR Order No 7118 7 15 ft 4 57 m Pin 1 Pin 8 Pin 1 C TY ain gt Pin 13 DA 6 WATT sae si ee ee Pin 14 f Pin 25 15 position D sub plug with locking posts is n 25 position D sub plug with screw locks ground hisia connected to backshgl ground shield connected to backshell CAB0005A Industry Interface Type RS 232 C Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 7 Signal Ground Transmitted Data 2 2 Transmitted Data Transmitter Signal Element 24 Transmitter Signal Element Timing Timing DTE Source DTE Source Transmitter Signal Element Timing 4 15 Transmitter Signal Element Timing DCE Source DCE Source Request to Send 6 4 Request to Send Clear to Send 8 6 Data Set Ready Data Carrier Detect 10 22 Ring Indicator Receiver Signal Element Timing 12 17 Receiver Signal Element Timing DCE Source DCE Source Received Data 14 3 Received Data Intern
55. Signal Signal Ground 1 B Signal Ground Transmit Data 2 R Receive Data A Transmit Data 3 T Receive Data B Serial Clock Transmit 4 Y Serial Clock Transmit A Serial Clock Transmit 5 AA Serial Clock Transmit B Request to Send 6 F Data Carrier Detect Data Carrier Detect 10 D Clear to Send Serial Clock Receive 11 X Serial Clock Receive B Serial Clock Receive 12 V Serial Clock Receive A Receive Data 13 S Transmit Data B Receive Data 14 P Transmit Data A Internal Wire Connections Pin6 gt 8 PinC gt D Pin 4 gt 12 Pin E gt H Pin5 gt 11 Pini gt 7 117339 A Rev A 6 25 Cable Guide 44 Pin D Sub to V 35 Leased Line or V 25bis Order No 7220 Pin 1 Se Pin 15 LAST a Pin 16 SO aane S Pin 30 ee Pin 31 7 gt _ Pin 44 44 position D sub plug with screw locks ground shield connected to backshell gt Sscnvurmo939 gt gt 34 position V 35 plug with screw jack retainers ground shield connected to backshell CABO106A Industry Interface Type V 35 V 10 and V 11 6 26 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal VSD 38 P Send Data A VSD 36 S Send Data B VRT 34 V Receive Timing A VRT 33 X Receive Timing B VST 32 Y Send Timing A VST 31 AA Send T
56. V Serial Clock Receive A Receive Data 13 T Receive Data B Receive Data 14 R Receive Data A Data Set Ready 15 E Data Set Ready Internal Wire Connections Pint gt 7 117339 A Rev A 6 21 Cable Guide 15 Pin D Sub to V 35 with DTR Order No 7216 4 OO lt N VIQOR Pin 1 aa and Ly Pin 8 ANY 6 nee ae 15 position D sub plug with locking posts ground shield connected to backshell Oe O00 800 O00 0 OO x lt ADTNODW AA 34 position V 35 plug with screw jack retainers ground shield connected to backshell CAB0040A Industry Interface Type V 35 V 10 and V 11 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 B Signal Ground Send Data 2 P Send Data A Send Data 3 S Send Data B Serial Clock Transmit 4 Y Serial Clock Transmit A Serial Clock Transmit 5 AA Serial Clock Transmit B Request to Send 6 C Request to Send Clear to Send 8 D Clear to Send Data Carrier Detect 10 F Data Carrier Detect Serial Clock Receive 11 X Serial Clock Receive B Serial Clock Receive 12 V Serial Clock Receive A Receive Data 13 i Receive Data B Receive Data 14 R Receive Data A Internal Wire Connections Pint gt 7 PinC gt H 6 22 117339 A Rev A Standard Synchronous Cables RS 232 Pass through 15 Pin to RS 232 Order No 7218
57. X 2 an E1 T1 line or an external T1 clock source Table 5 1 summarizes the cables Detailed cable illustrations and pinout specifications follow Table 5 1 E1 T1 Cables Order No Length Physical Cable Description Page AA0018001 10 ft 3 05 m MCE1 DB9 to mod jack cable 9 pin to RJ 45 5 4 AA0018002 10 ft 3 05 m MCE1 DB9 to unterminated end cable 9 pin to unterminated 5 5 end AA0018006 6 in 0 15 m Quad MCT1 clock cable 15 pin D sub plug and 9 position 5 6 D sub receptacle to 15 pin D sub receptacle AA0018014 10 ft 3 05 m MCE1 Ru 45 to RJ 45 5 7 AA0018015 10 ft 3 05 m MCE1 RJ 45 to unterminated end cable 5 8 AA0018021 15 ft 4 57 m Quad MCT1 crossover cable 15 pin D sub plug to 15 pin 5 9 D sub plug AA0018022 15 ft 4 57 m Quad MCT1 straight through cable 15 pin D sub plug to 5 10 15 pin D sub plug 7150 15 ft 4 57 m MCT1 clock cable 9 pin D sub plug to 15 pin D sub plug 5 11 7151 N A MCT1 loopback connector 15 pin D sub plug 5 12 7152 N A MCT1 loopback connector RJ 48 5 13 7153 15 ft 4 57 m MCT1 crossover cable 15 pin D sub plug to RJ 48 5 14 7154 15 ft 4 57 m MCT1 loopback cable RJ 48 to RJ 48 5 15 continued 117339 A Rev A Cable Guide Table 5 1 E1 T1 Cables continued Order No Length Physical Cable Description Page 7155 15 ft 4 57 m MCT1 loop
58. a 2 2 Send Data Receive Data 3 3 Receive Data Request to Send 4 4 Request to Send Clear to Send 5 5 Clear to Send Data Set Ready 6 6 Data Set Ready Data Terminal Ready 8 20 Data Terminal Ready Data Carrier Detect 9 8 Data Carrier Detect Send Timing 10 15 Send Timing Receive Timing 11 17 Receive Timing Transmitter Signal Element Timing 12 24 Transmitter Signal Element Timing Signal Ground 7 7 Signal Ground Internal Wire Connections Pin 7 gt 19 gt 20 gt 23 Pin 13 gt 28 Pin 14 gt 29 6 38 117339 A Rev A Standard Synchronous Cables RS 232 Pass through 44 Pin to RS 232 Order No 7833 DA 15 ft 4 57 m Pin 1 Pin 15 DEN Pinte TE EAA SST MES Pin 31 m Pin 44 44 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type RS 232 C ee al Sy Pin 1 gt Pin ex THI i ae Bin 25 25 position D sub plug with screw locks ground shield connected to backshell CABO0065A Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive Data 3 2 Send Data Send Data 2 3 Receive Data Data Carrier Detect 9 5 Clear to Send RTS 4 8 Data Carrier Detect Send Timing 10 17 Receive Timing Frame Ground 1 1 Frame Ground Signal Ground
59. able that satisfies your wiring requirement with the exception of total cable length Consult the networking industry specification standard or recommendation designated in the Industry Interface Type entry for that cable located immediately following the cable pinout diagram 5 2 117339 A Rev A E1 T1 Cables e Pinouts for each connector and all associated signals e Grounding arrangements that isolate the chassis from the DC ground within the cable 117339 A Rev A 5 3 Cable Guide MCE1 DB9 to Mod Jack Cable Order No AA0018001 Note This cable assembly uses a 120 ohm wire wt _ 3 05 m Pin 8 Pin 1 gt i ci We N el Ping RJ 45 connector 9 position D sub plug with screw locks ground shield connected to backshell CAB0087A Industry Interface Type E1 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive Tip 1 1 Receive Tip Receive Ring 6 2 Receive Ring Transmit Tip 5 4 Transmit Tip Transmit Ring 9 5 Transmit Ring Ground 3 3 Ground 5 4 117339 A Rev A E1 T1 Cables MCE1 DB9 to Unterminated Cable Order No AA0018002 Note This cable assembly uses a 120 ohm wire m 10 ft 3 05 m x fo err o 9 position D sub plug with screw locks ground shield connected to backshell Unterminated cable CAB0088A Industr
60. age 7219 15 ft 4 57 m V 35 synchronous pass through 15 pin D sub plug to V 35 6 24 plug 7220 15 ft 4 57 m 44 pin D sub plug to V 35 plug leased line or V 25bis for WAN 6 26 connection 7221 15 ft 4 57 m 15 pin D sub plug to X 21 plug for WAN connection 6 28 7224 15 ft 4 57 m 44 pin D sub plug to X 21 plug for WAN connection 6 29 7255 15 ft 4 57 m 15 pin D sub plug to RS 232 plug for WAN connection 6 30 7256 15 ft 4 57 m 15 pin D sub plug to V 28 plug for WAN connection 6 31 7260 15 ft 4 57 m 15 pin to 15 pin synchronous crossover for back to back 6 32 node operation 7315 15 ft 4 57 m 15 pin D sub plug to RS 422 plug for WAN connection 6 34 7318 15 ft 4 57 m 44 pin D sub plug to RS 422 plug leased line or V 25bis for 6 36 WAN connection 7826 15 ft 4 57 m 44 pin D sub plug to RS 232 plug leased line or V 25bis for 6 38 WAN connection 7833 15 ft 4 57 m RS 232 synchronous pass through 44 pin D sub plug to 6 39 RS 232 plug 7834 15 ft 4 57 m V 35 synchronous pass through 44 pin D sub plug to 6 40 V 35 plug 7835 15 ft 4 57 m Bay Networks V 35 crossover 44 pin D sub plug to 6 42 44 pin D sub plug 7836 15 ft 4 57 m V 35 crossover 44 pin D sub plug to 15 pin D sub plug 6 44 7837 15 ft 4 57 m 44 pin D sub plug to V 28 plug for WAN connection 6 46 7932 15 ft 4 57 m 50 pin to V 35 plug 6 48 7934 15 ft 4 57 m 50 pin to RS 232 6 50 7936 15 ft 4 57 m 50 pin to X 21 6 51 793
61. ainers ground shield connected to backshell CABO0080A Industry Interface Type V 35 V 10 and V 11 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Transmit Data 2 R Receive Data A Transmit Data 3 T Receive Data B Receive Data 14 P Transmit Data A Receive Data 13 S Transmit Data B Request to Send 6 F Data Carrier Detect Data Carrier Detect 10 D Clear to Send SCT 4 Y SCT A SCT 5 AA SCT B Signal Ground 1 B Signal Ground Internal Wire Connections Pini gt 7 PinC gt D Pin6 gt 8 PinY gt V Pin 4 gt 12 Pin AA gt X Pin5 gt 11 PinE gt H 117339 A Rev A 6 61 Cable Guide 44 Pin to F RS 232 Synchronous Pass through Order No 7943 i 15 ft _ Poen 4 57 m a i eS pi Pin 13 Pint a E oi D m o Pin 16 Ir 1 ey I PHN OT Pin 30 Cees 00000000000 Pin 31 SS pea Pin25 PINIS 44 position D sub plug with screw locks 25 position D sub receptacle with screw locks ground shield connected to backshell ground shield connected to backshell CABO081A Industry Interface Type RS 232 C Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send Data 2 3 Receive Data Receive Data 3 2 Send Data Request to Send 4 8 Data Carrier Detect Data C
62. al Ground 1 B Signal Ground Send Data 2 P Send Data A Send Data 3 S Send Data B Serial Clock Transmit 4 Y Send Timing A Serial Clock Transmit 5 AA Send Timing B Request to Send 6 C Request to Send Clear to Send 8 E Data Set Ready Data Carrier Detect 10 J Ring Indicator Serial Clock Receive 11 X Receive Timing B Serial Clock Receive 12 V Receive Timing A Receive Data 13 T Receive Data B Receive Data 14 R Receive Data A Internal Wire Connections Pini gt 7 gt 9 Pin C gt H Data Terminal Ready 7 10 117339 A Rev A Dialup Services Cables 44 Pin D Sub to V 35 Raise DTR Order No 7137 Pin 1 gt L Pin 15 no SS TTL Rindge L a Eves Pin 31 ve J Pin 44 44 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type V 35 V 10 and V 11 15 ft 4 57 m 3 i l x lt 4 0 0 C o Q OO OOO Go lt scwvrmo gt O 7 OOO OQ AA 34 position V 35 plug with screw jack retainers ground shield connected to backshell 117339 A Rev A Cable Guide Bay Networks Termination Remote Termination Signal Pin to Pin Signal Frame Ground 1 A Frame Ground Request to Send 4 C Request to Send Clear to Send 5 D Clear to Send Data Set Ready 6 E Data Set Ready Data Termin
63. al Ready 8 H Data Terminal Ready Data Carrier Detect 9 J Ring Indicator VTT 40 U Terminal Timing A VTT 39 W Terminal Timing B Signal Ground 19 B Signal Ground VST 32 Y Send Timing A VST 31 AA Send Timing B VRT 34 V Receive Timing A VRT 33 X Receive Timing B VRD 37 R Receive Data A VRD 35 T Receive Data B VSD 38 P Send Data A VSD 36 S Send Data B Internal Wire Connections Pin 7 gt 19 gt 20 gt 23 Pin 41 gt 42 gt 43 Pin 13 gt 28 Pin 14 gt 29 117339 A Rev A Dialup Services Cables 44 Pin D Sub to RS 232 Raise DTR Order No 7138 Pin 1 A L Pin 15 TSS eo eae Ir SEAE NSS PS Pin 31 r L Pin 44 44 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type RS 232 C Pin 1 D e Pin 13 SESE pn 25 25 position D sub plug with screw locks ground shield connected to backshell CAB0019A 117339 A Rev A 7 13 Cable Guide Bay Networks Termination Remote Termination Signal Pin to Pin Signal Frame Ground 1 1 Frame Ground Send Data 2 2 Send Data Receive Data 3 3 Receive Data Request to Send 4 4 Request to Send Clear to Send 5 5 Clear to Send Data Set Ready 6 6 Data Set Ready Signal Ground 7 7 Signal Ground Data Terminal Ready 8 20 Data T
64. al Wire Connections Pini gt 7 gt 9 Pin 4 gt 20 Data Terminal Ready 117339 A Rev A Cable Guide 15 Pin D Sub to RS 232 V 25bis Order No 7119 TE Pin 1 in in Pin ay AAA a e UNNT E i KAKXYN ieee Pin 15 Pin 14 SS Pin 25 15 position D sub plug with locking posts ground shield connected to backshell 25 position D sub plug with screw locks ground shield connected to backshell CABO0006A Industry Interface Type RS 232 C Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 7 Signal Ground Transmitted Data 2 2 Transmitted Data Transmitter Signal Element 3 24 Transmitter Signal Element Timing Timing DTE Source DTE Source Transmitter Signal Element Timing 4 15 Transmitter Signal Element Timing DCE Source DCE Source Request to Send 6 4 Request to Send Clear to Send 8 5 Clear to Send Data Carrier Detect 10 6 Data Set Ready Receiver Signal Element Timing 12 17 Receiver Signal Element Timing DCE Source DCE Source Received Data 14 3 Received Data Internal Wire Connections Pini gt 7 gt 9 Pin 4 gt 20 Data Terminal Ready 7 8 117339 A Rev A Dialup Services Cables 15 Pin D Sub to V 35 V 25bis Order No 7120 aa oo Pin 1 ice re Ping hiri WAY Pin 15 15 position D
65. ansmitted Data B Receive Data 14 Transmitted Data A Request to Send 15 12 Indication B Frame Ground 1 1 Frame Ground Internal Wire Connections Pin 6 gt 7 XA Pin 13 gt 14 X B Note You must move Jumpers A E to the X 21 2 3 position to support this interface 117339 A Rev A 6 5 Cable Guide 44 Pin F X 21 Synchronous Pass through Order No AA0018004 Note This cable provides you with a female termination as a DCE device 15 ft Ts 4 57 m Oee Pin 8 Z Pin 1 Pin 1 Pin 15 rn DEA ecocoeal Pin 16 RRR eee pe NNN ta pinso Pin 15 Pin 9 Pin 31 a Pin 44 44 position D sub plug with screw locks ground shield connected to backshell 15 position D sub receptacle with M 3 screw posts ground shield connected to backshell CABO090A Industry Interface Type X 21 6 6 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send Data 2 4 Receive Data A Send Data 16 11 Receive Data B Receive Data 3 2 Transmitted Data A Receive Data 17 9 Transmitted Data B Request to Send 4 5 Indication A Request to Send 18 12 Indication B Data Carrier Detect 9 3 Control A Data Carrier Detect 23 10 Control B Transmitter Timing 12 6 Timi
66. any may temporarily discontinue your service If possible they will notify you in advance but if advance notice is not practical you will be notified as soon as possible and will be informed of your right to file a complaint with the FCC If you experience trouble with the unit please contact the Bay Networks Technical Solutions Center in your area for service or repairs Repairs should be performed only by service personnel authorized by Bay Networks Inc United States 1 800 2LAN WAN Valbonne France 33 4 92 96 69 68 Sydney Australia 61 2 9927 8800 Tokyo Japan 81 3 5402 0180 You are required to notify the telephone company when you disconnect the unit from the network viii 117339 A Rev A This equipment complies with Part 68 of FCC Rules All direct connections to telephone network lines must be made using standard plugs and jacks compliant with FCC Part 68 Please note the following 1 You are required to request service from the telephone company before you connect the unit to a network When you request service you must provide the telephone company with the following data e When you request T1 Service you must provide the telephone company with The Facility Interface Code Provide the telephone company with all the codes below 04DU9 BN 1 544 MB D4 framing format 04DU9 DN 1 544 MB D4 framing format with B8ZF coding 04DU9 1KN 1 544 MB ESF framing format 04DU9 1SN 1 544 MB ESF framing format with
67. are platforms to WAN devices Table 6 1 summarizes the cables Detailed cable illustrations and pinout specifications follow Table 6 1 Standard Synchronous Cables Order No Length Physical Cable Description Page AA0018003 15 ft 4 57 m X 21 synchronous pass through 15 pin D sub plug to X 21 6 4 receptacle AA0018004 15 ft 4 57 m X 21 synchronous pass through 44 pin D sub plug to X 21 6 6 receptacle AA0018005 15 ft 4 57 m X 21 synchronous pass through 50 pin D sub plug to X 21 6 8 receptacle AA0018011 15 ft 4 57 m RS 530 straight through cable 15 pin to RS 530 plug 6 10 AA0018012 15 ft 4 57 m RS 530 straight through cable 44 pin to RS 530 plug 6 12 AA0018013 15 ft 4 57 m RS 530 straight through cable 50 pin to RS 530 plug 6 14 AA0018023 15 ft 4 57 m 50 pin to V 28 cable 6 16 7158 10 ft 3 05 m 15 pin to male V 35 plug 6 17 7159 10 ft 3 05 m 44 pin to male V 35 plug 6 18 7215 15 ft 4 57 m 15 pin D sub plug to V 35 plug no DTR for WAN connection 6 20 7216 15 ft 4 57 m 15 pin D sub plug to V 35 plug with DTR 6 22 7218 15 ft 4 57 m RS 232 synchronous pass through 15 pin D sub plug to 6 23 RS 232 plug continued 117339 A Rev A Cable Guide Table 6 1 Standard Synchronous Cables continued Order No Length Physical Cable Description P
68. arrier Detect 9 4 Request to Send Send Timing 10 15 Send Timing Frame Ground 1 1 Frame Ground Signal Ground 7 7 Signal Ground Internal Wire Connections Pin4 gt 5 Pin4 gt 5 Pin10 gt 11 gt 12 Pin 15 gt 17 Pin 13 gt 28 Pin 6 gt 20 Pin 14 gt 29 Pin 7 gt 19 gt 20 gt 23 6 62 117339 A Rev A Standard Synchronous Cables 44 Pin to F V 35 Synchronous Pass through Order No 7944 15 ft 4 57 m a is ao B Pint L Pi D OS A Da 3 F Pin 16 T EEE NS Pin 30 P R Pin 31 p Pin 44 s y 44 position D sub plug with screw locks Ww ground shield connected to backshell AA 34 position V 35 receptacle with screw jack retainers ground shield connected to backshell CAB0082A Industry Interface Type V 35 V 10 and V 11 117339 A Rev A 6 63 Cable Guide Bay Networks Termination Remote Termination Signal Pin to Pin Signal VSD 38 R Receive Data A VSD 36 T Receive Data B VRD 37 P Send Data A VRD 35 S Send Data B Request to Send F Data Carrier Detect Data Carrier Detect 9 C Request to Send VTT 40 Y Send Timing A VTT 39 AA Send Timing B Frame Ground A Frame Ground Signal Ground 7 B Signal Ground Internal Wire Connections Pin4 gt 5 PinC gt D Pin 32 gt 34 gt 40 Pin V gt Y Pin 31 gt 33 gt 39 Pin X gt AA Pin 13 gt 28
69. aseT Specification 10 Mb s CSMA CD over twisted pair e TEEE 802 5 Specification Token Ring e X3T9 5 Single Mode Fiber PMD Specification FDDI e ETA RS 449 RS 422A Standard e ETA RS 232 C Standard e CCITT V 10 V 11 V 28 V 35 Recommendations e CCITT X 21 Recommendation 117339 A Rev A 1 11 Cable Guide See also the manufacturer s specifications for any cables or connectors you want to use Specifications for attenuation per unit length of cable and for connector insertion loss are useful in helping you to determine the maximum amount of signal loss and therefore the maximum distance allowable between two directly connected network devices The physical interface on each device for example the connector on an Ethernet Link Module in a Bay Networks router hardware platform determines which industry specification standard or recommendation you need to consult for guidelines on how to customize your cables To assist you in determining which industry document you need to consult the description for each cable in this guide includes an Industry Interface Type description 117339 A Rev A Chapter 2 Console Modem Cables This chapter identifies the console modem cables that link Bay Networks router hardware platforms to DTE and DCE devices Table 2 1 summarizes the cables Detailed cable illustrations and pinouts follow Table 2 1 Console Modem Cables Order Physical Cable No Length D
70. ause radio interference in which case the user may be required to take appropriate measures To maintain compliance with FCC radio frequency emission limits shielded cables are required to connect equipment to other Class A certified devices and the use of quadshield RG 6 U type CATV cable is required for connection to the CATV system Any changes or modifications may void the user s authorization to operate this equipment EN 55 022 Statement This is to certify that the Bay Networks lt product or system name gt is shielded against the generation of radio interference in accordance with the application of Council Directive 89 336 EEC Article 4a Conformity is declared by the application of EN 55 022 Class B CISPR 22 Compliance is dependent upon the use of shielded lt TBD by product gt EC Declaration of Conformity This product conforms or these products conform to the provisions of Council Directive 89 336 EEC and 73 23 EEC The Declaration of Conformity is available on the Bay Networks World Wide Web site at www baynetworks com iv 117339 A Rev A Japan Nippon Requirements Only Voluntary Control Council for Interference VCCI Statement COR WHiVHS ESAS ASPs VCCI mHip RES FSA AMARHEECT COERtRERRCEAT SLE Hees AELTIE BOET CORALS RERT SRIEKSNSCEMHOST Voluntary Control Council for Interference VCCI Statement This is a Class A product based on the standard of the Voluntary Control Council for Interferenc
71. ay Networks Termination RJ 11 Receptacle Signal Pin to Pin Signal Receive A 1 4 Receive Data Transmit A 5 3 Transmit Data Receive B 6 5 Receive Data Transmit B 9 6 Transmit Data 3 6 117339 A Rev A LAN Cables FDDI FSD to FSD Order No 7135 ee ea Soe K o 32 81 ft 10 m o_SS Fixed shroud duplex connector Fixed shroud duplex connector CABO016A Industry Interface Type X3T9 5 PMD FDDI FDDI FSD to Straight Tip Order No 7136 LP SS CES Fixed shroud duplex connector 2 5 mm bayonet connector two places CAB0017A Industry Interface Type X3T9 5 PMD FDDI 117339 A Rev A 3 7 Cable Guide FDDI type SC Duplex to Straight Tip Order No 7164 for Single Mode Cable 9 ft 2 7 m 2 5 mm bayonet connector two places CAB0036A Industry Interface Type X3T9 5 PMD FDDI 3 8 117339 A Rev A LAN Cables FDDI type SC Duplex to SC Duplex Order No 7163 for Multimode Cable Order No 7165 for Single Mode Cable 9 ft 2 7 m CAB0035A Industry Interface Type X3T9 5 PMD FDDI 117339 A Rev A 3 9 Cable Guide ATM Cable SC to Straight Tip MMF Order No 7169 2 5 mm bayonet connector two places CAB0038A Industry Interface Type X3T9 5 PMD FDDI
72. back cable 15 pin D sub plug to 15 pin 5 16 D sub plug 7156 15 ft 4 57 m MCT1 straight through cable RJ 48 to RJ 48 5 17 7157 15 ft 4 57 m MCT1 straight through cable 15 pin D sub plug to 15 pin 5 18 D sub plug 7160 10 ft 3 05 m MCE1 DB9 to DB9 crossover cable 5 19 7161 10 ft 3 05 m MCE1 DB9 to DB9 straight through cable 5 20 7162 10 ft 3 05 m MCE1 cable 75Q coaxial 5 21 7167 10 ft 3 05 m MCE1 DB9 to DB15 straight through cable 5 22 7168 10 ft 3 05 m MCE1 DB9 to DB15 crossover cable 5 23 7401 1 ft 0 3 m 15 pin T1 Framer plug labeled DSX 1 or DSX 2 to 15 pin 5 24 DTE plug for CSU connection 7415 15 ft 4 57 m 15 pin T1 Framer plug labeled DSX 1 or DSX 2 to 15 pin 5 25 external Customer Premise Equipment CPE plug 7650 50 ft 15 24 m 15 position CSU network receptacle to RJ 45 for T carrier line 5 26 connection 7750 50 ft 15 24 m 15 position CSU network receptacle to spade terminals for 5 27 T carrier line connection If you need to order additional cables contact the Bay Networks Technical Solutions Center in your area See How to Get Help in the front matter The following sections include e Cable illustrations with the Bay Networks connector on the left and the remote connector on the right e Cable length information If you want to build a cable and you want to determine the maximum cable length appropriate for each of your interconnection requirements you should Identify in this chapter a c
73. cee cece eeeeeeeeeeeeeeeaeeeeeaees rniii 5 6 MCE1 RJ 45 to RJ 45 Cable Order No AA0018014 sssssssssesssssnnsissrnsrnssrnsrnsrrssrnsenns 5 7 MCE1 RJ 45 to Unterminated Cable Order No AA0018015 esseen 5 8 Quad MCT1 15 Pin to 15 Pin Crossover Cable OSE Na FA UE sites isan eset areas aces scush snesseantcnsatelual Aa 5 9 Quad MCT1 15 Pin to 15 Pin Straight through Cable der No AADDI SIZZ arssinat natn a aaa R 5 10 MOTI Clock Gable Order No 2 10 apaiia aaia aiaa e aAA 5 11 MCT1 15 Pin Loopback Connector Order NO F151 ssirsisirscsissiirariinnn as 5 12 MCT1 RJ 48 Loopback Connector Order No 7152 eessessessssesssssssrssrrsssrrsssrnesrnses 5 13 MCT1 Crossover Cable Order No 7158 0 0 P pe datedcct E A 5 14 MCTI Loopback Cable Order No TUIA secs ccciinscjasscciiacd cesnumnsdasceanseteuseaiedeccestasedanevers 5 15 MOTT Loopback Cable Order NO TTO siirinsesi aannaaien 5 16 MCT1 Straight through Cable Order No 7156 E E n e Gn ee 5 17 MGT Straight threvgh Gable Order No 7187 saisscsases picts ai 5 18 MCE1 Crossover Cable Order No 7160 cccccceeceeeeceeeceeeseeeeeeeeeeeeeeeeeaeeecaeeeneeenaeens 5 19 xiv 117339 A Rev A MCE1 Straight through Cable Order No 7161 ccccccccseeeeeeeeeeceeeeeeeeeseeaeseeeaeeeneaees 5 20 PET Coaxial Cable Order No 7 GE a ces cosrna sieved unnasssdeauuisieh sa cdiaases aidaa 5 21 MCE1 DB9 to DB15 Straight through Cable Order No 7167 ccc
74. ceive Tip 3 Receive Tip Receive Ring 11 11 Receive Ring 5 18 117339 A Rev A E1 T1 Cables MCE1 Crossover Cable Order No 7160 10 ft 3 05 m s wr J TE Pin 9 Pin 9 9 position D sub plug with screw locks 9 position D sub plug with screw locks ground shield connected to backshell ground shield connected to backshell CAB0033A Industry Interface Type E1 G 703 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive A RXA 1 5 Transmit A TXA Receive B RXB 6 9 Transmit B TXB Transmit A TXA 5 1 Receive A RXA Transmit B TXB 9 6 Receive B RXB Internal Wire Connections Pin 3 Shield Pin 3 Shield grounded to backshell 117339 A Rev A 5 19 Cable Guide MCE1 Straight through Cable Order No 7161 n 10 ft el 3 05 m Pin s N 7 E BE 5 i e ZI e fe ZN e l Pin 9 Ta 9 9 position D sub plug with screw locks 9 position D sub plug with screw locks ground shield connected to backshell ground shield connected to backshell CAB0033A Industry Interface Type E1 G 703 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive A RXA 1 1 Receive A RXA Receive B RXB 6 6 Receive B RXB Transmit A TXA 5 5 Transmit A TXA Transmit B TXB 9 9 Transmit B TXB Internal Wire Connections Pin 3
75. ctrique du minist re des Communications du Canada Canadian Department of Communications Radio Interference Regulations This digital apparatus lt product or system name gt does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications R glement sur le brouillage radio lectrique du minist re des Communications Cet appareil num rique lt product or system name gt respecte les limites de bruits radio lectriques visant les appareils num riques de classe B prescrites dans le R glement sur le brouillage radio lectrique du minist re des Communications du Canada Canada CS 03 Rules and Regulations Note The Canadian Department of Communications label identifies certified equipment The certification means that the equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection In some cases the company s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly telephone extension cord The customer shoul
76. d be aware that compliance with the above conditions may not prevent the degradation of service in some situations Repairs to certified equipment should be made by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate Notice For equipment using loopstart lines please note that the Ringer Equivalence Number REN assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices does not exceed 5 0 The REN is located on the FCC Rules Part 68 label located on the bracket of the module or on the back of the unit vi 117339 A Rev A Canada CS 03 Regles et reglements Note L tiquette du minist re des Communications
77. e Licensee s requirements b that the Software will operate in the hardware or software combinations that the Licensee may select c that the operation of the Software will be uninterrupted or error free or d that all defects in the operation of the Software will be corrected Bay Networks is not obligated to remedy any Software defect that cannot be reproduced with the latest Software release These warranties do not apply to the Software if it has been i altered except by Bay Networks or in accordance with its instructions ii used in conjunction with another vendor s product resulting in the defect or iii damaged by improper environment abuse misuse accident or negligence THE FOREGOING WARRANTIES AND LIMITATIONS ARE EXCLUSIVE REMEDIES AND ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Licensee is responsible for the security of 117339 A Rev A xi its own data and information and for maintaining adequate procedures apart from the Software to reconstruct lost or altered files data or programs 4 Limitation of liability IN NO EVENT WILL BAY NETWORKS OR ITS LICENSORS BE LIABLE FOR ANY COST OF SUBSTITUTE PROCUREMENT SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES RESULTING FROM INACCURATE OR LOST DATA OR LOSS OF USE OR PROFITS ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE SOFTWARE EV
78. e Tip Receive Ring 11 11 Receive Ring Ground 2 4 Ground Ground 2 4 Ground a You must configure onboard jumpers to complete this connection Refer to the table called QMCT1 Link Module Settings in nstalling T1 Link Modules in BN Platforms 5 10 117339 A Rev A E1 T1 Cables MCT1 Clock Cable Order No 7150 15 ft 4 57 m O aS Pin 1 Pin 8 F lo seu el fo TN oy MOINS a l we ease Pin 15 Pin 9 9 position D sub plug with screw locks 15 position D sub plug with locking posts ground shield connected to backshell ground shield connected to backshell CAB0022A Industry Interface Type T1 DS1 External Clock Input from an External T1 Timing Source Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive Tip 2 1 Transmit Tip Receive Ring 3 9 Transmit Ring 117339 A Rev A 5 11 Cable Guide MCT1 15 Pin Loopback Connector Order No 7151 15 position connector CAB0023A Bay Networks Termination Remote Termination Signal Pin to Pin Signal Transmit Tip 1 3 Receive Tip Transmit Ring 9 11 Receive Ring 5 12 117339 A Rev A MCT1 RJ 48 Loopback Connector Order No 7152 RJ 48 connector CAB0024A E1 T1 Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive Ring 1 4 Transmit Ring Recei
79. e by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions Voluntary Control Council for Interference VCCI Statement COR WHUBERSRRRSR ERM VCCI OFM THOS TSI RRRRRERTT OF SBRRTMATAT SL SBAMLLTWETA CORBA Stes lL ELS sa gt FAREL HAAnNSL SEMBSISHCPcCeasNET RBIs TEL ARO Re LO Keb Voluntary Control Council for Interference VCCI Statement This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment VCCI If this is used near a radio or television receiver in a domestic environment it may cause radio interference Install and use the equipment according to the instruction manual 117339 A Rev A Canada Requirements Only Canadian Department of Communications Radio Interference Regulations This digital apparatus lt product or system name gt does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications R glement sur le brouillage radio lectrique du minist re des Communications Cet appareil num rique lt product or system name gt respecte les limites de bruits radio lectriques visant les appareils num riques de classe A prescrites dans le R glement sur le brouillage radio le
80. e or technical data or any direct product thereof to any country to which such exports or re exports are restricted or embargoed under United States export control laws and regulations or to any national or resident of such restricted or embargoed countries or ii provide the Software or related technical data or information to any military end user or for any military end use including the design development or production of any chemical nuclear or biological weapons 9 General If any provision of this Agreement is held to be invalid or unenforceable by a court of competent jurisdiction the remainder of the provisions of this Agreement shall remain in full force and effect This Agreement will be governed by the laws of the state of California Should you have any questions concerning this Agreement contact Bay Networks Inc 4401 Great America Parkway P O Box 58185 Santa Clara California 95054 8185 LICENSEE ACKNOWLEDGES THAT LICENSEE HAS READ THIS AGREEMENT UNDERSTANDS IT AND AGREES TO BE BOUND BY ITS TERMS AND CONDITIONS LICENSEE FURTHER AGREES THAT THIS AGREEMENT IS THE ENTIRE AND EXCLUSIVE AGREEMENT BETWEEN BAY NETWORKS AND LICENSEE WHICH SUPERSEDES ALL PRIOR ORAL AND WRITTEN AGREEMENTS AND COMMUNICATIONS BETWEEN THE PARTIES PERTAINING TO THE SUBJECT MATTER OF THIS AGREEMENT NO DIFFERENT OR ADDITIONAL TERMS WILL BE ENFORCEABLE AGAINST BAY NETWORKS UNLESS BAY NETWORKS GIVES ITS EXPRESS WRITTEN CONSENT INCLUDING AN EXPRESS W
81. end 30 13 Clear to Send B Data Set Ready 6 6 DCE Ready A Data Set Ready 31 22 DCE Ready B Data Terminal Ready 8 20 DTE Ready A Data Terminal Ready 33 23 DTE Ready B Data Carrier Detect 9 8 Receive Line Signal Detect A Data Carrier Detect 34 10 Receive Line Signal Detect B Send Timing 10 15 Transmitter Signal Element Timing DCE A Send Timing 35 12 Transmitter Signal Element Timing DCE B 6 14 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive Timing 11 17 Receiver Signal Element Timing DCE A Receive Timing 36 9 Receiver Signal Element Timing DCE B Transmitter Timing 12 24 Transmitter Signal Element Timing DTE A Transmitter Timing 37 11 Transmitter Signal Element Timing DTE B Signal Ground 7 7 Signal Ground Internal Wire Connections Pin 13 gt 38 Pin 14 gt 39 Pin 46 gt 48 117339 A Rev A 6 15 Cable Guide 50 Pin to V 28 Cable Order No AA0018023 Pin 1 a 25 Pin 26 Pin 50 50 position 0 8 mm plug ground shield connected to internal shell Industry Interface Type V 28 V 10 Pin 1 lt B gt Pints CUCU UUU UU E WEEE n car i Pin 25 25 position D sub plug with M 3 jack screws ground shield connected t
82. end 8 9 Clear to Send A Data Carrier Detect 9 31 Data Carrier Detect B Data Carrier Detect 10 13 Data Carrier Detect A Serial Clock Receive 11 26 Receive Timing B Serial Clock Receive 12 8 Receive Timing A Receive Data 13 24 Receive Data B Receive Data 14 6 Receive Data A Internal Wire Connections Pin7 gt 12 Pin 25 gt 30 gt 37 Note You must move Jumpers B and C to the X 21 2 3 position to support this interface 117339 A Rev A 6 35 Cable Guide 44 Pin D Sub to RS 422 Leased Line or V 25bis Order No 7318 15 ft 4 57 m tl t a Pint 3 Pin15 Pint O Pin 19 2S any sf O TIT Pin 16 i SA AAAAAAAAAAAAN 77 Pin 30 CAAAAAAAOOONAAANA J Coa Pin 31 AS gt pin 44 Pin 20 Pin 37 44 position D sub plug with screw locks 37 position D sub plug with screw locks ground shield connected to backshell ground shield connected to backshell CAB0051A Industry Interface Type RS 449 RS 422 6 36 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Data Carrier Detect 23 31 Receiver Ready B Data Carrier Detect 9 13 Receiver Ready A Send Data 2 4 Send Data A Send Data 16 22 Send Data B Receive Timing 1
83. end Timing 10 15 Transmitter Signal Element Timing DCE A Send Timing 24 12 Transmitter Signal Element Timing DCE B 6 12 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive Timing 11 17 Receiver Signal Element Timing DCE A Receive Timing 25 9 Receiver Signal Element Timing DCE B Transmitter Timing 12 24 Transmitter Signal Element Timing DTE A Transmitter Timing 26 11 Transmitter Signal Element Timing DTE B Signal Ground 7 7 Signal Ground Internal Wire Connections Pin 13 gt 28 Pin 14 gt 29 Pin 41 gt 43 117339 A Rev A 6 13 Cable Guide 50 Pin to RS 530 Straight through Order No AA0018013 a 15 ft al 4 57 m 5 2o n Pin 2 Pin 1 _ a a oi Joins Pin 26 wae ar 50 Pin 14 a o ET Pin 25 groia shila connected to henaa Sten nD aati ae CABOO9SA Industry Interface Type RS 530 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send Data 2 2 Transmitted Data A Send Data 27 14 Transmitted Data B Receive Data 3 3 Receive Data A Receive Data 28 16 Receive Data B Request to Send 4 4 Request to Send A Request to Send 29 19 Request to Send B Clear to Send 5 5 Clear to Send A Clear to S
84. environment allows for a DSU configuration from 300 Kb s to 52 Mb s For additional information about enabling internal clocking refer to Using Technician Interface Software router software or Administration Guide BayStream software 117339 A Rev A 4 5 Cable Guide Bay Networks Termination A Bay Networks Termination B Signal Pin to Pin Signal Signal Ground 1 1 Signal Ground Signal Ground 26 26 Signal Ground Receive Timing 2 9 Terminal Timing Receive Timing 27 34 Terminal Timing DCE Available 3 8 DTE Available DCE Available 28 33 DTE Available Receive Data 4 11 Send Data Receive Data 29 36 Send Data Signal Ground 7 7 Signal Ground Signal Ground 32 32 Signal Ground DTE Available 8 3 DCE Available DTE Available 33 28 DCE Available Terminal Timing 9 2 Receive Timing Terminal Timing 34 27 Receive Timing Send Data 11 4 Receive Data Send Data 36 29 Receive Data Signal Ground 13 13 Signal Ground Signal Ground 38 38 Signal Ground Signal Ground 19 19 Signal Ground Signal Ground 44 44 Signal Ground Signal Ground 25 25 Signal Ground Signal Ground 50 50 Signal Ground 4 6 117339 A Rev A Chapter 5 E1 T1 Cables This chapter identfies the cables that interconnect a T1 Framer or MCT1 link module with a channel service unit CSU or T1 Digital Signal Cross Connect switch DSX 1 or DS
85. er a cable that satisfies your interconnection requirement with the exception of total cable length Consult the networking industry specification standard or recommendation designated in the Industry Interface Type entry for that cable located immediately following the cable pinout diagram Pinouts for each connector and all associated signals except for the FDDI cables which have no wire connections Grounding arrangements that isolate the chassis of an attached device from the DC ground within the cable when applicable 117339 A Rev A Ethernet Cable Order No 7115 LAN Cables ma 15 ft o 4 57 m Pime A ee Teee ra BANE CEZ me S 15 Pinis Pin9 15 position D sub plug with locking posts 15 position D sub receptacle with slide latch ground shield connected to backshell connected to backshell CAB0002A Industry Interface Type Ethernet 802 3 Bay Networks Termination Transceiver Termination Signal Pin to Pin Signal Collision 2 2 Collision 802 3 Circuit CI A Transmit 3 3 Transmit 802 3 Circuit DO A Receive 5 5 Receive 802 3 Circuit DI A Voltage Common 6 6 Voltage Common 802 3 Circuit VC Collision 9 9 Collision 802 3 Circuit Cl B Transmit 10 10 Transmit 802 3 Circuit DO B Receive 12 12 Receive 802 3 Circuit DI B 12V 13 13 12V 802 3 Circuit VP 117339 A Rev A 3 3 Cable Guide
86. erminal Ready Data Carrier Detect 9 22 Ring Indicator Send Timing 10 15 Send Timing Receive Timing 11 17 Receive Timing Transmitter Signal Element Timing 12 24 Transmitter Signal Element Timing Internal Wire Connections Pin 7 gt 19 gt 20 gt 23 Pin 13 gt 28 Pin 14 gt 29 117339 A Rev A Dialup Services Cables 44 Pin D Sub to RS 422 Raise DTR Order No 7139 Pin 1 VAY L Pin 15 ST a Pin 16 HANNAN LS pin 30 E SAAAAAANANNAAN Pin 31 La l Pin 44 44 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type RS 449 RS 422 rE Pin 1 i B CO e SNOT PTT T ATT tit J Pin 20 Pin 37 37 position D sub plug with screw locks ground shield connected to backshell CABO0020A 117339 A Rev A 7 15 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send Data 2 4 Send Data A Send Data 16 22 Send Data B Receive Data 3 6 Receive Data A Receive Data 17 24 Receive Data B Request to Send 4 7 Request to Send A Request to Send 18 25 Request to Send B Clear to Send 5 9 Clear to Send A Clear to Send 19 27 Clear to Send B Data Set Ready 6 11 Data Mode A Data Set Ready 20 29 Data Mode B Terminal
87. ermination Remote Termination Signal Pin to Pin Signal Frame Ground 1 1 Frame Ground Send Data 2 2 Send Data Receive Data 3 3 Receive Data Request to Send 4 4 Request to Send Clear to Send 5 5 Clear to Send Data Set Ready 6 6 Data Set Ready Signal Ground 7 7 Signal Ground Data Terminal Ready 8 20 Data Terminal Ready Data Carrier Detect 9 8 Data Carrier Detect Send Timing 10 15 Send Timing Receive Timing 11 17 Receive Timing Terminal Timing 12 24 Terminal Timing Signal Ground 7 7 Signal Ground Internal Wire Connections Pin 7 gt 30 gt 31 gt 34 Pin 13 gt 38 Pin 14 gt 39 6 50 117339 A Rev A Standard Synchronous Cables 50 Pin to X 21 Order No 7936 jen Pin 1 _bENa_ Pin 25 Bd aes ed ay rns ae D 6 WAY Nanni VA LAANA e D Pin 9 eee Pin 15 Pin 26 Pin 50 50 position 0 8 mm plug 15 position D sub plug with M 3 jack screws ground shield connected to internal shell ground shield connected to backshell CAB0074A Industry Interface Type X 21 V 11 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send Data 2 2 Transmitted Data A Send Data 27 9 Transmitted Data B Request to Send 4 3 Control A Request to Send 29 10 Control B Receive Data 3 4 Receive Data A Receive Data 28 11 Receive Data B Data Carrier Detect 9 5 Indication A Data Carrier D
88. es to the appropriate industry specification standard or recommendation documents Recommended documents typically contain technical information to help you determine your requirements for cable installation path cable type maximum cable length and so on 117339 A Rev A 1 1 Cable Guide Before You Begin To ensure that you order make or use the appropriate cable for your router hardware platform first answer the following questions e What is the connection category order number or physical description of the cable I want to find e What type of physical interface am I connecting to and what type of cable connector plug or receptacle do I need to make this connection Note Determining the connector type you need can significantly decrease the time it takes to locate the appropriate cable For example if you want to connect to a 44 position synchronous interface look only for synchronous cables with 44 pin plugs e What type of device do I want to connect to the router hardware platform s physical interface For example do you want to connect a modem or a console to the router hardware platform Each function requires a different cable even though you connect to the same physical interface on the router hardware platform e What version of software is my router hardware platform using For example newer features such as dialup services may require special cable pin configurations to interoperate with earlie
89. escription Connection Page 7525 25 ft 25 pin D sub plug to Console modem interface to any ASCII 2 3 7 63 m RS 232 C receptacle terminal for all devices except AFN and AN 7526 25 ft AFN AN console cable Console modem interface to any ASCII 2 4 7 63 m 9 pin D sub plug to terminal for AFN and AN only RS 232 C receptacle 7527 10 ft AT serial console cable Console modem interface kit contains a 2 5 3 05 m 9 pin D sub plug to modem cable and a null modem adapter RS 232 C modem plug to a console 7825 25 ft 9 pin D sub plug to Console modem interface to a dial modem 2 6 7 63 m RS 232 C modem plug for all devices except BLN BLN 2 and BCN 77850 15 ft 25 pin D sub plug to Console modem interface to a dial modem 2 7 4 57 m RS 232 C modem plug for BLN BLN 2 and BCN only If you need to order additional cables contact the Bay Networks Technical Solutions Center in your area See How to Get Help in the front matter 117339 A Rev A 2 4 Cable Guide The following sections include Cable illustrations with the Bay Networks connector on the left and the remote connector on the right Cable length information If you want to build a cable and you want to determine the maximum cable length appropriate for that interconnection requirement you should Identify in this chapter a cable that satisfies your interconnection requirement with the exception of total cable length Consult the network
90. etect 34 12 Indication B Timing 10 6 Timing A Timing 35 13 Timing B Frame Ground 1 1 Frame Ground Signal Ground 7 8 Signal Ground Internal Wire Connections Pin 46 gt 48 GRD Pin 38 gt 40 Pin 14 gt 15 117339 A Rev A 6 51 Cable Guide 50 Pin to RS 422 Order No 7937 15ft 4 57 m is y a a pini L Pin 19 rw a pak 4 e SUTTTTTTETEYY NANNY o Pin 50 J Pin 20 Pin 37 37 position D sub plug with screw locks ground shield connected to backshell 50 position 0 8 mm plug ground shield connected to internal shell CAB0075A Industry Interface Type RS 449 RS 422 6 52 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Data Carrier Detect 34 31 Receiver Ready B Data Carrier Detect 13 Receiver Ready A Send Data 4 Send Data A Send Data 27 22 Send Data B Receive Timing 11 8 Receive Timing A Receive Timing 36 26 Receive Timing B Send Timing 10 5 Send Timing A Send Timing 35 23 Send Timing B Receive Data 3 6 Receive Data A Receive Data 28 24 Receive Data B Clear to Send 30 27 Clear to Send B Clear to Send 5 9 Clear to Send A Request to Send 4 Request to Send A Request to Send 29 25 Request to Send B Data Set
91. ev A 2 7 Chapter 3 LAN Cables This chapter identifies the local area network LAN cables that link Bay Networks router hardware platforms to other LAN devices Table 3 1 summarizes the cables Detailed cable illustrations and pinouts follow Table 3 1 Local Area Network Cables Order No Length Physical Cable Description Connection Page 7115 15 ft 15 pin AUI plug to Bay Networks Ethernet 802 3 XCVR 3 3 4 57 m 15 position AUI receptacle interface to an Ethernet AUI network connection 7125 15 ft 9 pin D sub plug to Token Bay Networks Token Ring 802 5 3 4 4 57 m Ring 802 5 MAU data connector MAU interface to a Token Ring STP cable network connection 7126 15 ft 9 pin D sub plug to Token Bay Networks Token Ring 802 5 3 5 4 57 m Ring 802 5 MAU data connector MAU interface to a Token Ring with ferrite bead STP cable network connection 7128 1 ft 9 pin D sub plug to RJ 11 Bay Networks Token Ring 802 5 3 6 0 3 m receptacle MAU interface to a Token Ring network connection 7135 32 81 ft FSD to FSD connectors dual Bay Networks PHY A or PHY B 3 7 10 m attachment to FDDI ring requires interface to an FDDI FSD network two cables connection 7136 32 81 ft FSD to ST connectors dual Bay Networks PHY A or PHY B 3 7 10 m attachment to FDDI ring requires interface to a bayonet type FDDI two cables network connection continued 117339 A Rev A 3 1 Cable Guide Table 3 1 Loca
92. gt 29 Pin 41 gt 42 gt 43 Pin 41 gt 42 gt 43 117339 A Rev A 6 43 Cable Guide V 35 Crossover 44 Pin to 15 Pin Order No 7836 15ft 4 57 m i j Pin 1 in SS AE RY ANY NANN x Pi i Pin 16 ames tie it ys Wl in 30 mo a ale Pin 31 Pin 44 15 position D sub plug with locking posts ground shield connected to backshell 44 position D sub plug with screw locks ground shield connected to backshell CAB0068A Industry Interface Type V 35 V 10 and V 11 6 44 117339 A Rev A Standard Synchronous Cables Bay Networks Termination A Bay Networks Termination B Signal Pin to Pin Signal VSD 38 14 Receive Data A VSD 36 13 Receive Data B VRT 34 4 SCTA VRT 33 5 SCT B VTT 40 12 SCRA VTT 39 11 SCR B VRD 37 2 Send Data A VRD 35 3 Send Data B Request to Send 4 10 Data Carrier Detect A Data Carrier Detect 9 8 Clear to Send A Signal Ground 7 1 Signal Ground Internal Wire Connections Pin 32 gt 40 Pin6 gt 8 Pin 31 gt 39 Pint gt 7 gt 9 gt 15 Pin4 gt 5 Pin 7 gt 19 gt 20 gt 23 Pin 13 gt 28 Pin 14 gt 29 Pin 41 gt 42 gt 43 117339 A Rev A 6 45 Cable Guide 44 Pin D Sub to V 28 Order No 7837 Pin 1 ig L Pin15 Dn Pin 16 A YVWV S
93. gt 42 gt 43 117339 A Rev A 6 59 Cable Guide 15 Pin to F RS 232 Synchronous Pass through Order No 7941 15ft 4 57 m TR Pin 1 Pin 8 i i Eea LI Pin 13 gt Pin 1 R HAY R o ee aaa Pin 25 LL 15 position D sub plug with locking posts 25 position D sub receptacle with screw locks ground shield connected to backshell ground shield connected to backshell CABO0079A Pin 14 Industry Interface Type RS 232 C Bay Networks Termination Remote Termination Signal Pin to Pin Signal Transmit Data 2 3 Receive Data Receive Data 14 2 Transmit Data Request to Send 6 8 Data Carrier Detect Data Carrier Detect 10 4 Request to Send Transmit Clock 4 15 Transmit Clock Signal Ground 1 7 Signal Ground Internal Wire Connections IPin6 gt 8 Pin4s gt 5 Pin3 gt 4 gt 12 Pin15 gt 17 Pint gt 7 gt 9 Pin 6 gt 20 6 60 117339 A Rev A Standard Synchronous Cables 15 Pin to F V 35 Synchronous Pass through Order No 7942 tT 15 ft 4 57 m Pin 1 lt 7 S Pin 8 ONY ae SEs ie 15 position D sub plug with locking posts ground shield connected to backshell gt j H lt scnvrmo oO O00 OO 0o09 3 i O OO O x lt 4 Dnw AA 34 position V 35 receptacle with screw jack ret
94. h 15 Pin to RS 232 Order No 7218 cscceeeeeseerenees nA 6 23 V35 Pass through 15 Pin to V 35 Order NO 7219 esciens 6 24 44 Pin D Sub to V 35 Leased Line or V 25bis Order No 7220 ecceeeeseeeseeeeeeetteeees 6 26 15 F it D Sub to X 21 Order NO 7221 cccssetiacteant ceed neice A 6 28 44 Pin D Sub ie 4 21 Order No 7224 sn iecidaseeiuatel sen ida aaa teat 6 29 15 Pin D Sub to RS 232 Order No 7255 oai E ysabicbentatelanceee ae oede 6 30 19 PN D SUB ie V28 Order NO 7290 cccaskerciescnssteiciemiacesane e aS 6 31 15 Fin Giossover Order NO TAGO caissintscctcduasascdvisierdennoiesdetaads exodus aN ENAS 6 32 15 Pin D Sub to RS 422 Order No 7315 PE EE ccibeedvascnieeanie aa 6 34 44 Pin D Sub to RS 422 Leased Line or V 25bis Order No 7318 cccccccscssenscesace er er re capitis estes PEE re ioei PEEN 6 36 117339 A Rev A XV 44 Pin D Sub to RS 232 Leased Line or V 25bis PROTO 1 O20 a cscaicenuiiaiateereenan i A EE EE Gena 6 38 RS 232 Pass through 44 Pin to RS 232 Order No 7833 cccccceseeeeeeeeeseeeeeeeees 6 39 V 35 Pass through 44 Pin to V 35 Order No 7834 0 ccccesseeeseeeeeeeeeeeeeeeeeaeeeeeneeeeas 6 40 V 35 Crossover 44 Pin to 44 Pin Order No 7835 E E Gums ees 6 42 V 35 Crossover 44 Pin to 15 Pin Order No 7836 sesssessssssssssssssssrnsssrnssrnsssressse 6 44 44 Fin D Sub to Y 28 Order No FEOF aisctivenccdectrnatanaeeeien ce inana iia i 6 46
95. ice Order Code s SOC 6 0N The make model number and FCC Registration number of the NT1 Note ISDN S T cannot be directly connected to the network e When you request Primary Rate ISDN Service you must provide the telephone company with The Facility Interface Code 04DU9 1SN 1 544 MB ESF framing format with B8ZF coding The Service Order Code s SOC 6 0F The required Universal Service Order Code USOC jack RJ48C 117339 A Rev A ix Your telephone company may make changes to its facilities equipment operations or procedures that could affect the proper functioning of your equipment The telephone company will notify you in advance of such changes to give you an opportunity to maintain uninterrupted telephone service If the unit causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance but if advance notice is not practical you will be notified as soon as possible and will be informed of your right to file a complaint with the FCC If you experience trouble with the unit please contact the Bay Networks Technical Solutions Center in your area for service or repairs Repairs should be performed only by service personnel authorized by Bay Networks Inc United States 1 800 2LAN WAN Valbonne France 33 4 92 96 69 68 Sydney Australia 61 2 9927 8800 Tokyo Japan 81 3 5402 0180 You are required to notify the telephone company when
96. ility provided they have agreed to use the Software only in accordance with the terms of this license 3 Limited warranty Bay Networks warrants each item of Software as delivered by Bay Networks and properly installed and operated on Bay Networks hardware or other equipment it is originally licensed for to function substantially as described in its accompanying user manual during its warranty period which begins on the date Software is first shipped to Licensee If any item of Software fails to so function during its warranty period as the sole remedy Bay Networks will at its discretion provide a suitable fix patch or workaround for the problem that may be included in a future Software release Bay Networks further warrants to Licensee that the media on which the Software is provided will be free from defects in materials and workmanship under normal use for a period of 90 days from the date Software is first shipped to Licensee Bay Networks will replace defective media at no charge if it is returned to Bay Networks during the warranty period along with proof of the date of shipment This warranty does not apply if the media has been damaged as a result of accident misuse or abuse The Licensee assumes all responsibility for selection of the Software to achieve Licensee s intended results and for the installation use and results obtained from the Software Bay Networks does not warrant a that the functions contained in the software will meet th
97. iming B VRD 37 R Receive Data A VRD 35 T Receive Data B Data Set Ready E Data Set Ready Data Terminal Ready H Data Terminal Ready Request to Send C Request to Send Clear to Send D Clear to Send VTT 40 U Terminal Timing A VTT 39 W Terminal Timing B Frame Ground 1 A Frame Ground Data Carrier Detect 9 F Data Carrier Detect Signal Ground 19 B Signal Ground Internal Wire Connections Pin 7 gt 19 gt 20 gt 23 Pin 41 gt 42 gt 43 Pin 13 gt 28 Pin 14 gt 29 117339 A Rev A 6 27 Cable Guide 15 Pin D Sub to X 21 Order No 7221 15 ft ay 4 57 m Sy a uno ESI aT vol CHUN MOIKAN Pin 9 a Pin 15 mere oT 15 position D sub plug with locking posts 15 position D sub plug with M 3 jack screws ground shield connected to backshell ground shield connected to backshell CAB0044A Industry Interface Type X 21 V 11 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Ground 1 1 Ground Send Data 2 2 Transmitted Data A Send Data 3 9 Transmitted Data B Request to Send 6 3 Control A Request to Send 15 10 Control B Receive Data 14 4 Receive Data A Receive Data 13 11 Receive Data B Data Carrier Detect 10 5 Indication A Data Carrier Detect 9 12 Indication B Send Timing 4 6 Timing A Send Timing 5 13 Timing B Note You must mo
98. in to Pin Signal Send 1 1 Send Send 9 Send Receive 3 Receive Receive 11 11 Receive 117339 A Rev A 5 25 Cable Guide CSU Network Receptacle to RJ 45 Order No 7650 ees 50 ft _ 15 24 m Pin 8 Tege Pin 1 Pin 8 _ FS Pin 1 Ce Mi Pin 15 Pin 9 15 position D sub receptacle with slide latch RJ 45 connector connected to backshell CAB0057A Industry Interface Type T1 DS1 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send 1 5 Send Send 9 4 Send Receive 2 Receive Receive 11 1 Receive 5 26 117339 A Rev A E1 T1 Cables CSU Network Receptacle to Spade Terminals Order No 7750 pe enn D i Pin 8 qz gt Pin 1 Erec TO Pin 15 oes RJ 15 position D sub receptacle with slide latch Spade terminals connected to backshell P Ping CABO0058A Industry Interface Type T1 DS1 Bay Networks Termination Remote Termination Signal Pin to Signal Wire Signal Send 1 wire XMIT Send 9 wire XMIT Receive 3 wire Receive Receive 11 wire Receive Ground Chassis wire Shield Ground Chassis wire Shield 117339 A Rev A 5 27 Chapter 6 Standard Synchronous Cables This chapter identifies the standard synchronous cables that link Bay Networks router softw
99. in 1 EE pin ts eet x S Pnn eaa Pin 16 A POPP RRR RRR 7 Pin 30 Pin 15 S ng ERAAN Pin 31 AS a eee 15 position D sub receptacle with slide latch 44 position D sub plug with screw locks connected to backshell ground shield connected to backshell CAB0010A Industry Interface Type RS 422 Caution You cannot use this cable adapter to provide a clock master to an attached service This is a passive straight through cable 117339 A Rev A 8 9 Cable Guide Bay Networks Termination Termination to Existing Cable Signal Pin to Pin Signal Send Data 2 2 Send Data Send Data 16 3 Send Data Receive Data 3 14 Receive Data Receive Data 17 13 Receive Data Data Carrier Detect 9 10 Data Carrier Detect Data Carrier Detect 23 9 Data Carrier Detect Request to Send 4 6 Request to Send Request to Send 18 15 Request to Send Clear to Send 5 8 Clear to Send Clear to Send 19 7 Clear to Send Send Timing 10 4 Serial Clock Transmit Send Timing 24 5 Serial Clock Transmit Receive Timing 11 12 Serial Clock Receive Receive Tlming 25 11 Serial Clock Receive Signal Ground 7 1 Signal Ground Internal Wire Connections Pin 13 gt 28 Pin 14 gt 29 Pin 41 gt 43 8 10 117339 A Rev A Cable Adapters 50 Pin to 44 Pin Cable Adapter Order N
100. in 12 gt 10 ST Pin 6 gt 7 XA Pin 37 gt 35 ST Pin 13 gt 14 X B Pin 14 gt 15 Pin 38 gt 40 Pin 46 gt 48 117339 A Rev A 6 9 Cable Guide 15 Pin to RS 530 Straight through Order No AA0018011 tT 15 ft _ I 4 57 m Pin 1 A aA Pin 8 Pin 1 lt Pin 13 DANE TA CREE 6 MV n AAAALAAAANANS Pin9 ae aoe Pin 15 DS ee Pin 14 Pin 25 15 position D sub plug with locking posts 25 position D sub plug with screw locks ground shield connected to backshell ground shield connected to backshell CAB0093A Industry Interface Type RS 530 6 10 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send Data 2 2 Transmitted Data A Send Data 3 14 Transmitted Data B Receive Data 14 3 Receive Data A Receive Data 13 16 Receive Data B Request to Send 6 4 Request to Send A Request to Send 15 19 Request to Send B Clear to Send 8 5 Clear to Send A Clear to Send 7 13 Clear to Send B Data Carrier Detect 10 8 Receive Line Signal Detect A Data Carrier Detect 10 Receive Line Signal Detect B Send Timing 15 Transmitter Signal Element Timing DCE A Send Timing 5 12 Transmitter Signal Element Timing DCE B Receive Timing 12 17 Receiver Signal Element Timing D
101. ing industry specification standard or recommendation designated in the Industry Interface Type entry for that cable located immediately following the cable pinout diagram Pinouts for each connector and all associated signals Internal wire connections for each termination when applicable For example the console port to ASCII terminal cable Order No 7525 lists internal wire connections such as Pin 6 gt 20 in the Remote Termination column This indicates that you must connect pin 6 to pin 20 inside the remote termination Grounding arrangements that isolate the chassis from the DC ground within the cable when applicable 2 2 117339 A Rev A Console Modem Cables Console Interface to ASCII Terminal Order No 7525 Caution Do not use this cable to attach a modem to any Bay Networks router hardware platform Use this cable only to attach an ASCII terminal to any Bay Networks router hardware platform except a model AN or AFN 25 ft e a TSS SSS jl e NAAA AAA AAAAY I o le Vgecoooccvoegll o Pin 14 OS Pn as Pn25 Pin 14 25 position D sub plug with screw locks 25 position D sub receptacle with screw locks ground shield connected to backshell ground shield connected to backshell CABO0S4A Industry Interface Type RS 232 C Bay Networks Termination Remote Termination Signal Pin
102. ith slide latch connected to backshell CABOOI0A Caution You cannot use this cable adapter to provide a clock master to an attached service This is a passive straight through cable 117339 A Rev A 8 3 Cable Guide Bay Networks Termination Termination to Existing Cable Signal Pin to Pin Signal Send Data 2 2 Send Data Receive Data 3 14 Receive Data Request to Send 4 6 Request to Send Clear to Send 5 8 Clear to Send Data Set Ready 6 15 Data Set Ready Data Carrier Detect 9 10 Data Carrier Detect Send Timing 10 4 Send Timing Receive Timing 11 12 Receive Timing Transmitter Timing 12 Transmitter Timing Signal Ground 7 7 Signal Ground Internal Wire Connections Pin 7 gt 19 gt 20 gt 23 Pin1 gt 7 gt 9 Pin 13 gt 28 Pin 14 gt 29 117339 A Rev A Cable Adapters 44 Pin to 15 Pin X 21 Cable Adapter Order No 7123 Note This adapter enables you to connect an existing 15 pin X 21 cable gt Order No 7221 to a 44 pin port This cable assembly automatically selects the X 21 interface Pin 1 Pin 1 ENA Pin 8 FTIT T S Pin 15 Poe VASNA TISS olen iy pes TRAN o Pin 30 eS SS Pin 31 rop Ping J Pin 44 15 position D sub receptacle with slide latch 44 position D sub plug with screw locks connected to backshell
103. j Pin 30 E M M M IAA J Pin 44 Vad ies c HU Pin 31 i 44 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type V 28 V 10 Pin 1 i D gt Pin 13 TATTIUUUUNVNNN oY ee Pin 25 25 position D sub plug with M 3 jack screws ground shield connected to backshell CABO0069B 6 46 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Frame Ground 1 1 Frame Ground Send Data 2 2 Send Data Receive Data 3 3 Receive Data Request to Send 4 4 Request to Send Clear to Send 5 5 Clear to Send Data Set Ready 6 6 Data Set Ready Data Terminal Ready 8 20 Data Terminal Ready Data Carrier Detect 9 8 Data Carrier Detect Send Timing 10 15 Send Timing Receive Timing 11 17 Receive Timing Transmitter Signal Element 12 24 Transmitter Signal Element Timing Timing Signal Ground 7 7 Signal Ground Internal Wire Connections Pin 7 gt 19 gt 20 gt 23 Pin 13 gt 28 Pin 14 gt 29 117339 A Rev A 6 47 Cable Guide 50 Pin to V 35 Order No 7932 15 ft 4 57 m en _BE Sa Pin 25 C a 50 50 position 0 8 mm plug ground shield connected to internal shell Pin 1 ii Pin 26 Industry Interface
104. l Area Network Cables continued Order No Length Physical Cable Description Connection Page 7163 9 ft 2 7 m FDDI SC duplex to SC duplex Bay Networks PHY A or PHY B 3 9 connectors multimode fiber interface to a type SC FDDI network cable dual attachment to FDDI connection ring requires two cables 7164 9 ft 2 7 m FDDI SC duplex to bayonet ST Bay Networks PHY A or PHY B 3 8 connectors single mode fiber interface to a type ST FDDI network cable dual attachment to FDDI connection ring requires two cables 7165 9 ft 2 7 m FDDI SC duplex to SC duplex Bay Networks PHY A or PHY B 3 9 connectors single mode fiber interface to a type SC FDDI network cable dual attachment to FDDI connection ring requires two cables 7169 9 ft 2 7 m ATM SC duplex to bayonet ST Bay Networks PHY A or PHY B 10 connectors single mode fiber interface to a type ST FDDI network cable dual attachment to FDDI connection ring requires two cables If you need to order additional cables contact the Bay Networks Technical Solutions Center in your area See How to Get Help in the front of this book The following sections include Cable illustrations with the Bay Networks connector on the left and the remote connector on the right Cable length information If you want to build a cable and you want to determine the maximum cable length appropriate for that interconnection requirement you should Identify in this chapt
105. le 5 6 AAO0018011 15 pin to RS 530 straight through cable 6 10 AA0018012 44 pin to RS 530 straight through cable 6 12 AA0018013 50 pin to RS 530 straight through cable 6 14 AA0018014 MCE1 RJ 45 to RJ 45 cable 5 7 AA0018015 MCE1 RJ 45 to unterminated cable 5 8 AAO0018021 Quad MCT1 crossover cable 5 9 AA0018022 Quad MCT straight through cable 5 10 117339 A Rev A AA0018023 50 pin to V 28 cable 6 16 AA0018024 50 pin to 15 pin RS 422 cable adapter 8 16 AFN AN console interface to ASCII terminal cable 2 4 ATM cable SC to straight tip MMF 3 10 Attachment Unit Interface AUD defined 1 9 basics connector 1 8 Bay Networks Press xxv BLN BLN 2 or BCN to modem cable 2 7 building cables 1 11 Cc cable adapters RS 232 44 pin to 15 pin 8 3 RS 422 44 pin to 15 pin 8 9 RS 422 50 pin to 15 pin 8 16 V 35 44 pin to 15 pin 8 7 V 35 50 pin to 15 pin 8 14 V 35 50 pin to 44 pin 8 11 X 21 44 pin to 15 pin 8 5 cables building your own 1 11 finding in this guide 1 4 listed by category 1 3 type 1 1 CCITT series connectors defined 1 9 channel service unit CSU 5 1 coaxial cables MCE1 5 21 connection categories 1 3 console cables AFN and AN only 2 4 all devices except AFN and AN 2 3 AT serial connection 2 5 listed 2 1 crossover cables 15 pin to 15 pin 6 32 50 pin to 15 pin 6 56 50 pin to 44 pin 6 58 50 pin to 50 pin 6 54 HSSI 4 5 MCEI 9 pin to 15 pin 5 23
106. le 1 3 Table 2 1 Table 3 1 Table 4 1 Table 5 1 Table 6 1 Table 7 1 Table 8 1 117339 A Rev A Tables Cable Gategoiy LOGaNONe ccscicsiister ni anA eet hiaase 1 3 Cables Listed by Order Number cccccecsceesssecesteeeeseeseseeecsaeeeeeeees 1 4 SEU TNE ceio aeeie EE 1 8 Console Modem Cables sscirrcaviwniienasmiiossiamenrenaz0n aaa 2 1 Local Area Network Cables seni utes AIEE EEEE EE E L ee 3 1 POSC NN a a 4 1 E E E A ee te eenee tie eemee emer cert roteet ete eer eee 5 1 Standard Synchronous Cables cccsseeeesseseeeeeeseeeees EE 6 1 Hiap Services Cado raain EAE aes 7 1 Console Nodem COIS assirinassi idid o AEs EERTSE Saia 8 1 About This Guide If you are responsible for installing Bay Networks router hardware platforms read this guide to discover how to attach the correct cables to the router you are installing This guide provides e Cable connector diagrams e Pin socket wiring configurations connect to different ports If you want to Go to Learn basic information about cable connections and learn how to Chapter 1 build your own cables Learn about the console modem cables that link Bay Networks router Chapter 2 hardware platforms to DTE and DCE devices Learn about the LAN cables that link Bay Networks router hardware Chapter 3 platforms to other LAN devices Learn about the High Speed Serial Interface HSSI cables that link Chapter 4 Bay Network
107. lose the dust cover when you attach a fiber optic cable connector to its counterpart connector Replace dust covers when you detach a fiber optic cable from any local device Figure 1 1 shows a sample of connectors in cable assemblies for Bay Networks router hardware platforms 117339 A Rev A Cable Guide Attachment Unit Recommended Interface AUI series RS connector connector Registered jack RJ Spade CCITT terminals series V 35 connector Fixed shroud duplex FSD connector Type SC duplex connector Straight tip bayonet connector BNC CABOO0LA Figure 1 1 Connector Types 1 10 117339 A Rev A Cable Basics Building Your Own Cables Cables that you build must comply with standard cable specifications and network requirements Cable length cable type cable and connector attenuation and other factors affect the overall performance and reliability of your network For example using a cable length longer than that recommended in industry standards or interface specifications or using a cable type that is unsuitable considering the cable environment temperature electrical noise radio frequency rf emissions and other factors may degrade network performance and reliability For additional information about maximum cable length and other factors consult the appropriate EIA IEEE CCITT or ISO specification standard or recommendation Some examples include e IEEE 802 3 10B
108. minal Timing A VTT 39 W Terminal Timing B Signal Ground 19 B Signal Ground VST 32 Y Send Timing A VST 31 AA Send Timing B VRT 34 V Receive Timing A VRT 33 X Receive Timing B VRD 37 R Receive Data A VRD 35 T Receive Data B VSD 38 P Send Data A VSD 36 S Send Data B Internal Wire Connections Pin 7 gt 19 gt 20 gt 23 Pin 41 gt 42 gt 43 Pin 13 gt 28 Pin 14 gt 29 117339 A Rev A 6 19 Cable Guide 15 Pin D Sub to V 35 No DTR for WAN Order No 7215 a 15 ft 4 57 m Pin 1 Pin 8 lt i HUW O o WANY 6 Ping Pin 15 15 position D sub plug with locking posts ground shield connected to backshell 34 position V 35 plug with screw jack retainers ground shield connected to backshell CABO0039A Industry Interface Type V 35 V 10 and V 11 6 20 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 B Signal Ground Send Data 2 P Send Data A Send Data 3 S Send Data B Serial Clock Transmit 4 Y Serial Clock Transmit A Serial Clock Transmit 5 AA Serial Clock Transmit B Request to Send 6 C Request to Send Clear to Send 8 D Clear to Send Data Carrier Detect 10 F Data Carrier Detect Serial Clock Receive 11 X Serial Clock Receive B Serial Clock Receive 12
109. n V 35 cable adapter 8 14 77850 25 pin D sub plug to RS 232 C modem plug for BLN BCN console modem 2 7 interface to dial modem connection 117339 A Rev A 1 7 Cable Guide Cable Connector Basics Before using this guide you should be familiar with its terminology and the connector types Bay Networks provides Connector Terminology This guide uses several terms to describe generically the various types of connectors and their physical electrical attributes Table 1 3 lists these terms and their definitions Table 1 3 Connector Terms Term Description Pins These are the short rigid lead wires protruding from a plug type connector The pins of a plug connector penetrate and make electrical contact with counterpart sockets or holes in a receptacle type connector Sockets These are the holes in a receptacle type connector Each hole Accepts one counterpart pin of a plug type connector Completes an electrical connection to its counterpart pin Plug This type of connector provides a number of pins and attaches to a receptacle type connector Receptacle This type of connector provides a number of sockets or holes that accept the pins of a plug type connector Physical This is a plug or receptacle type connector located on the router hardware platform interface or on a device such as an Ethernet transceiver The physical interface accepts an appropriate counterpart cable connector Termination This is
110. ng A Transmitter Timing 26 13 Timing B Frame Ground 1 1 Frame Ground Signal Ground 7 8 Signal Ground Internal Wire Connections Pin 12 gt 10 ST Pin 6 gt 7 XA Pin 26 gt 24 ST Pin 13 gt 14 X B Pin14 gt 15 Pin 28 gt 30 Pin 41 gt 43 117339 A Rev A 6 7 Cable Guide 50 Pin to F X 21 Synchronous Pass through Order No AA0018005 Note This cable provides you with a female termination as a DCE device 15 ft 4 57 m EEK YZL pee 50 position 0 8 mm plug ground shield connected to internal shell Pin 1 Pin 25 Pin 26 Pin 50 Industry Interface Type X 21 Pin 8 AS Pin 1 Nocospool Pin 15 Ping 15 position D sub receptacle with M 3 screw posts ground shield connected to backshell CAB0091A 6 8 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send Data 2 4 Receive Data A Send Data 27 11 Receive Data B Receive Data 3 2 Transmitted Data A Receive Data 28 9 Transmitted Data B Request to Send 4 5 Indication A Request to Send 29 12 Indication B Data Carrier Detect 9 3 Control A Data Carrier Detect 34 10 Control B Transmitter Timing 12 6 Timing A Transmitter Timing 37 13 Timing B Frame Ground 1 1 Frame Ground Signal Ground 7 8 Signal Ground Internal Wire Connections P
111. o 7947 Note This adapter cable allows you to connect an existing 44 pin cable to a 50 pin port The interface is automatically selected ER oS a 25 Pin ee a Pin 1 L o99000000000000 7 Pin 30 9 9000000000 00 0 0 LA _ C n WNL ooooo0o00000000 oe RRES ILa A Pin 44 y Pin 31 50 position 0 8 mm plug ground shield connected to internal shell 44 position D sub receptacle with screw locks ground shield connected to backshell CAB0085A Industry Interface Type Cable dependent 117339 A Rev A 8 11 Cable Guide Bay Networks 50 Pin Termination Bay Networks 44 Pin Termination Signal Pin to Pin Signal Frame Ground 1 1 Frame Ground Send Data 2 2 Send Data Send Data 27 16 Send Data Receive Data 3 3 Receive Data Receive Data 28 17 Receive Data Request to Send 4 4 Request to Send Request to Send 29 18 Request to Send Clear to Send 5 5 Clear to Send Clear to Send 30 19 Clear to Send Data Set Ready 6 6 Data Set Ready Data Set Ready 31 20 Data Set Ready Signal Ground 7 7 Signal Ground Data Terminal Ready Data Terminal Ready Data Terminal Ready 33 22 Data Terminal Ready Data Carrier Detect 9 9 Data Carrier Detect Data Carrier Detect 34 23 Data Carrier De
112. o Send C Request to Send Clear to Send 5 D Clear to Send VTT 45 U Terminal Timing A VTT 20 W Terminal Timing B Frame Ground A Frame Ground Data Carrier Detect 9 J Ring Indicator Signal Ground 30 B Signal Ground Internal Wire Connections Pin 7 gt 30 gt 31 gt 34 Pin 46 gt 47 gt 48 Pin 13 gt 38 Pin 14 gt 39 117339 A Rev A Dialup Services Cables 50 Pin to RS 232 with Raise DTR Order No 7935 15 ft 4 57 m Pin 1 Pin 25 Pin 1 gt Pin 13 EI ge gt TUTTI N Se aa 50 Pin 14 re Pin 25 50 position 0 8 mm plug ground shield connected to internal shell vai Pin 26 25 position D sub plug with screw locks ground shield connected to backshell CAB0072A Industry Interface Type RS 232 C Bay Networks Termination Remote Termination Signal Pin to Pin Signal Frame Ground 1 1 Frame Ground Send Data 2 2 Send Data Receive Data 3 3 Receive Data Request to Send 4 4 Request to Send Clear to Send 5 5 Clear to Send Data Set Ready 6 6 Data Set Ready Data Terminal Ready 8 20 Data Terminal Ready Data Carrier Detect 9 22 Ring Indicator Send Timing 10 15 Send Timing Receive Timing 11 17 Receive Timing Terminal Timing 12 24 Terminal Timing Signal Ground 7 7 Signal Ground Internal Wire
113. o backshell CAB0103A Bay Networks Termination Remote Termination Signal Pin to Pin Signal Frame Ground 1 1 Frame Ground Send Data 2 2 Send Data Receive Data 3 3 Receive Data Request to Send 4 4 Request to Send Clear to Send 5 5 Clear to Send Data Set Ready 6 6 Data Set Ready Signal Ground 7 7 Signal Ground Data Terminal Ready 8 20 Data Terminal Ready Data Carrier Detect 9 8 Data Carrier Detect Send Timing 10 15 Send Timing Receive Timing 11 17 Receive Timing Terminal Timing N 24 Terminal Timing Internal Wire Connections Pin 7 gt 30 gt 31 gt 34 Pin 13 gt 38 Pin 14 gt 39 6 16 117339 A Rev A Standard Synchronous Cables 15 Pin to V 35M Order No 7158 10 ft 3 05 m Pint lt lt Pin 8 N a x lt ADTNODW we COC B OO 5 OO OCO O OO lt onvUIO gt Pin 9 Pin 15 15 position D sub plug with locking posts ground shield connected to backshell AA 34 position V 35 plug with screw jack retainers ground shield connected to backshell CAB0030A Industry Interface Type V 35 V 10 and V 11 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 B Signal Ground Send Data 2 P Send Data Signal A Send Data 3 S Send
114. pin to 44 pin crossover 6 42 standards industry 1 11 straight tip connector defined 1 9 synchronous pass through cables See pass through cables T T1 5 1 T1 cables CSU DTE connection 5 24 CSU network receptacle to RJ 45 5 26 CSU network receptacle to spade terminals 5 27 customer premises connection 5 25 Framer 5 24 to 5 26 listed 5 1 multichannel clock 5 11 multichannel crossover 5 14 multichannel loopback 5 15 5 16 multichannel straight through 5 17 5 18 quad multichannel 5 6 quad multichannel crossover 5 9 quad multichannel straight through 5 10 Technical Solutions Centers xxvi termination defined 1 8 terminology 1 8 Token Ring cables 3 4 to 3 6 Index 6 U using this guide 1 2 V V 28 cables 15 pin to 6 31 44 pin synchronous to 6 46 50 pin synchronous to 6 16 V 28 interface defined 1 9 V 35 cables 15 pin synchronous with DTR 6 22 15 pin to 6 20 6 24 15 pin to male 6 17 44 pin to 6 26 44 pin to male 6 18 50 pin to 6 48 V 35 interface defined 1 9 X X 21 V 11 cables 15 pin to 6 28 44 pin to 6 29 50 pin to 6 51 X 21 cables 15 pin to 6 4 44 pin to 6 6 44 pin to 15 pin cables adapter 8 5 50 pin to 6 8 X 21 interface defined 1 9 X3T9 5 PMD FDDI cables FDDI FSD to FSD 3 7 SC duplex to SC duplex 3 9 SC duplex to straight tip 3 8 SC to straight tip MMF 3 10 117339 A Rev A
115. plex MM fiber cable 3 9 7164 FDDI SC duplex to straight tip SM fiber cable 3 8 7165 FDDI SC duplex to SC duplex SM fiber cable 3 9 7167 MCE1 DB9 to DB1S straight through cable 5 22 7168 MCE1 DB9 to DB15 crossover cable 5 23 7169 ATM cable 3 10 7215 15 pin to synchronous V 35 cable 6 20 7216 15 pin synchronous to V 35 with DTR cable 6 22 7218 RS 232 synchronous pass through cable 6 23 7219 15 pin synchronous to V 35 pass through cable 6 24 7220 44 pin synchronous to V 35 cable 6 26 7221 15 pin synchronous to X 21 cable 6 28 7224 44 pin synchronous to X 21 cable 6 29 7255 15 pin synchronous to RS 232 cable 6 30 7256 15 pin synchronous to V 28 cable 6 31 7260 15 pin to 15 pin crossover cable 6 32 Index 1 7315 15 pin synchronous to RS 422 cable 6 34 7318 44 pin synchronous to RS 422 cable 6 36 7401 T1 to CSU DTE cable 5 24 7415 T1 to Customer Premise Equipment cable 5 25 7525 console cable for all except AFN and AN 2 3 7526 console cable AFN AN only 2 4 7527 AT serial console cable 2 5 7650 CSU network receptacle to RJ 45 cable 5 26 7750 CSU network receptacle to spade terminals cable 5 27 77850 modem cable for BLN BLN 2 or BCN platforms only 2 7 7825 modem cable for all except BLN BLN 2 or BCN platform 2 6 7826 44 pin synchronous to RS 232 cable 6 38 7830 HSSI DCE to DTE 10 ft cable 4 3 7831 HSSI DCE to DTE 50 ft cable 4 3
116. plug to 15 pin D sub plug 5 16 7156 MCT1 straight through cable RJ 48 to RJ 48 5 17 7157 MCT1 straight through cable 15 pin D sub plug to RJ 48 5 18 7158 15 pin synchronous plug to V 35 plug 6 17 7159 44 pin D sub plug to V 35 plug 6 18 7160 MCE1 crossover cable 9 pin 5 19 7161 MCE1 straight through cable 9 pin 5 20 7162 MCE1 cable 75Q coaxial 5 21 7163 FDDI SC duplex to SC duplex connectors multimode fiber cable dual attachment 3 9 to FDDI ring requires two cables 7164 FDDI SC duplex to bayonet ST connectors single mode fiber cable dual 3 8 attachment to FDDI ring requires two cables 7165 FDDI SC duplex to SC duplex connectors single mode fiber cable dual attachment 3 9 to FDDI ring requires two cables continued 117339 A Rev A 1 5 Cable Guide Table 1 2 Cables Listed by Order Number continued Order No Physical Cable Description Page 7167 MCE1 DB9 to DB15 straight through cable 5 22 7168 MCE1 DB9 to DB15 crossover cable 5 23 7169 ATM cable SC to ST MMF 3 10 7215 15 pin D sub plug to V 35 plug no DTR for WAN connection 6 20 7216 15 pin D sub plug to V 35 plug with DTR 6 22 7218 RS 232 synchronous pass through 15 pin synchronous plug to RS 232 plug for 6 23 DTE connection 7219 V 35 synchronous pass through 15 pin synchronous plug to V 35 plug for DTE 6 24 connection 7220 44 pin D sub plug
117. r versions of Bay Networks software How to Use This Guide You can find the Bay Networks cable you want by e Cable connection category e Cable order number or description 1 2 117339 A Rev A Finding Cables by Category Cable Basics This guide separates Bay Networks cables into seven connection categories Table 1 1 shows the chapter that contains each category Table 1 1 Cable Category Locations Category Chapter No Console Modem 2 Local Area Network LAN 3 Ethernet Token Ring Fiber Distributed Data Interface FDDI Asynchronous Transfer Mode ATM High Speed Serial Interface HSSI 4 Multichannel E1 T1 T1 Framer and Channel Service Unit CSU 5 Standard Synchronous 6 Coaxial Crossover and Loopback Straight through Pass through Dialup Services 7 Cable Adapters 8 After determining the connection category and type of connector that you need go to the appropriate chapter The table at the beginning of each chapter provides additional information about each cable in that category 117339 A Rev A Cable Guide Finding Cables by Order Number or Description Table 1 2 lists the order number a brief description and the page number of each cable in this guide Table 1 2 Cables Listed by Order Number Order No Physical Cable
118. requirement you should Identify in this chapter a cable that satisfies your interconnection requirement with the exception of total cable length Consult the networking industry specification standard or recommendation designated in the Industry Interface Type entry for that cable located immediately following the cable pinout diagram e Pinouts for each connector and all associated signals e Internal wire connections for each termination when applicable For example the 44 pin to 15 pin RS 232 cable adapter Order No 7122 lists internal wire connections such as Pin 13 gt 28 in the Bay Networks Termination column This indicates that you must connect pin 13 to pin 28 inside the Bay Networks termination e Grounding arrangements that isolate the chassis from the DC ground within the cable when applicable 8 2 117339 A Rev A Cable Adapters 44 Pin to 15 Pin RS 232 Cable Adapter Order No 7122 selects the RS 232 interface Note This adapter enables you to connect an existing 15 pin RS 232 cable Order No 7255 or 7256 to a 44 pin port This cable assembly automatically Pin 1 a SL Pin 15 ESS ae Wa Pin 16 i Ti Wien Cen Pin 30 Pin 31 a nay 44 position D sub plug with screw locks ground shield connected to backshell Industry Interface Type RS 232 C Pin 8 SSS Pin 1 Leet Ping 15 position D sub receptacle w
119. rface Type V 28 V 10 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 7 Signal Ground Transmitted Data 2 Transmitted Data Transmitter Timing 24 Transmitter Signal Element DTE Source Timing DTE Source Transmitter Signal Element Timing 4 15 Transmitter Signal Element Timing DCE Source DCE Source Request to Send 6 4 Request to Send Clear to Send 8 Clear to Send Carrier Detect 10 Carrier Detect Receiver Signal Element 12 17 Receiver Signal Element Timing DCE Source Timing DCE Source Received Data 14 3 Received Data Data Set Ready 15 6 Data Set Ready Internal Wire Connections Pint gt 7 gt 9 Pin 4 gt 20 117339 A Rev A 6 31 Cable Guide 15 Pin Crossover Order No 7260 Note This crossover cable interconnects two Bay Networks router software platforms 15 ft gt as ali Pin 1 lt lt 7 Pin 8 Pint lt A La Pin 8 TONNI 5 TONNI VAAN VITANN Pin 9 E Pin 15 Pin 9 Pin 15 15 position D sub plug with locking posts 15 position D sub plug with locking posts ground shield connected to backshell ground shield connected to backshell CABO0049A Industry Interface Type V 35 6 32 117339 A Rev A Standard Synchronous Cables Bay Networks Termination A Bay Networks Termination B Signal Pin to Pin Signal Signal Ground 1 15 Return Common
120. s 7 9 15 Pin D Sub to V 35 Raise DTR Order No 7121 inina AEE E TT PEET 7 10 44 Pin D Sub to V 35 Raise DTR Order No Z137 sccciscscccnscpiascissarddoctsaseidcasseemsionsiiess 7 11 44 Pin D Sub to RS 232 Raise DTR Order No 7138 eccceececeeeseeeeeeeeeeeeeeeseeeeeeaee 7 13 44 Pin D Sub to RS 422 Raise DTR Order No 7139 0 0 ee ania PEREA 7 15 50 Pin to V 35 with Raise DTR Order No 7933 enincnndiseniisisniiaiini ai 7 17 50 Pin to RS 232 with Raise DTR Order No 7935 c eeescceseceeeeneeeeeeeeeeeaeeeseeeeeeaae 7 19 xvi 117339 A Rev A Chapter 8 Cable Adapters 44 Pin to 15 Pin RS 232 Cable Adapter Order No 7122 cccecececeeseeeeeeeeeeeteeeteneeetees 8 3 44 Pin to 15 Pin X 21 Cable Adapter Order No 7123 eccceeeeeeeeeeeneeeeeeeeeeseeeeeeeeees 8 5 44 Pin to 15 Pin V 35 Cable Adapter Order No 7124 Eionn ee Getteeuniaes 8 7 44 Pin to 15 Pin RS 422 Cable Adapter Order No 7131 eeccceeeceeeeeseeeeeteeeeeneeeesees 8 9 50 Pin to 44 Pin Cable Adapter Order No 7947 ccccccecseeeeeeeeeeeeeeeeeeeeeeeeeeeeneeeeaees 8 11 50 Pin to 15 Pin V 35 Cable Adapter Order No 7948 o ccceeesceeeeeeeeeeeeeeeeeeeeeeaeeeees 8 14 50 Pin to 15 Pin RS 422 Cable Adapter Order No AA0018024 nesens EETA re esini ennai re 8 16 117339 A Rev A xvii Figures moe tel Connec Wipes u dents irene arena esbu eles 1 10 117339 A Rev A xix Table 1 1 Table 1 2 Tab
121. s router hardware platforms to LAN and WAN devices Learn about the cables that interconnect a T1 Framer or MCT1 link Chapter 5 module with a Channel Service Unit CSU or T1 Digital Signal Cross Connect switch DSX 1 or DSX 2 an E1 T1 line or an external T1 clock source Learn about the standard synchronous cables that link Bay Networks Chapter 6 router hardware platforms to WAN devices Learn about dialup services cables necessary for linking Bay Chapter 7 Networks router hardware platforms to WAN dial on demand and dial backup devices Learn about the cable and adapters that enable existing cables to Chapter 8 117339 A Rev A xxiii Cable Guide Conventions italic text Indicates variable values in command syntax descriptions new terms file and directory names and book titles separator gt Separates internal pin to pin wire connections Example Pin 7 gt 19 gt 20 Acronyms ATM asynchronous transfer mode AUI Attachment Unit Interface CCITT International Telegraph and Telephone Consultative Committee now ITU T CPE Customer Premise Equipment CSMA CD catrier sense multiple access with collision detection CSU channel service unit DCE data communications equipment DSU digital service unit DTE data terminal equipment DTR data terminal ready EIA Electronic Industries Association FC Fiber Channel FDDI Fiber Distributed Data Interface FSD fixed shroud duplex HSSI High Speed Serial Interface T
122. shield connected to backshell CAB0096B Industry Interface Type E1 G 703 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive A 1 1 Transmit A Receive B 6 9 Transmit B Transmit A 5 3 Receive A Transmit B 9 11 Receive B Internal Wire Connections Pin 3 gt Shield 117339 A Rev A 5 23 Cable Guide T1 to CSU DTE Order No 7401 tT 12 in 0 3 m p A _ ne Jo oun Yol ate oee A VN Cag Pin 9 lt Pin 15 Pin 15 Pin 9 15 position D sub plug with locking posts 15 position D sub receptacle with slide latch ground shield connected to backshell connected to backshell CABO0052A Industry Interface Type T1 DS1 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send 1 1 Send Send 9 9 Send Receive 3 3 Receive Receive 11 11 Receive 5 24 117339 A Rev A E1 T1 Cables T1 to Customer Premise Equipment Order No 7415 15 ft 4 57 m Pin 1 lt 7 aey Ping Pin 1 se ay Ping TN NAAN VTE NOON mee args a eer eer 15 position D sub plug with locking posts 15 position D sub plug with locking posts ground shield connected to backshell ground shield connected to backshell CABO0053A Industry Interface Type T1 DS1 Bay Networks Termination Remote Termination Signal P
123. sition D sub plug with locking posts ground shield connected to backshell ground shield connected to backshell CAB0027A Industry Interface Type T1 DS1 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Transmit Tip 1 3 Receive Tip Receive Tip 3 1 Transmit Tip Transmit Ring 9 11 Receive Ring Receive Ring 11 9 Transmit Ring 5 16 117339 A Rev A E1 T1 Cables MCT1 Straight through Cable Order No 7156 RJ 48 connector Industry Interface Type T1 DS1 Pin 8 Pin 1 i RJ 48 connector CAB0028A Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive Tip 1 1 Receive Tip Receive Ring 2 2 Receive Ring Transmit Tip 4 4 Transmit Tip Transmit Ring 5 5 Transmit Ring 117339 A Rev A 5 17 Cable Guide MCT1 Straight through Cable Order No 7157 15 ft o Pin Mea 7 Pins PARRA OUCUUNN le Varn re T PUNE Pin 9 Pin 15 Pin 9 Pin 15 15 position D sub plug with locking posts 15 position D sub plug with locking posts ground shield connected to backshell ground shield connected to backshell CAB0105A Industry Interface Type T1 DS1 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Transmit Tip 1 1 Transmit Tip Transmit Ring 9 Transmit Ring Re
124. smit Data Receive Data 3 3 Receive Data Request to Send 4 4 Request to Send Clear to Send 5 5 Clear to Send Data Set Ready 6 6 Data Set Ready Signal Ground 7 7 Signal Ground Carrier Detect 8 8 Carrier Detect Data Terminal Ready 9 20 Data Terminal Ready 2 6 117339 A Rev A Console Modem Cables Backbone Console Interface to RS 232 C Modem Order No 77850 Caution This is a modem cable Do not use this cable to attach an ASCII terminal to a Bay Networks router hardware platform Use this cable only to attach a modem to a Bay Networks model BLN BLN 2 or BCN platform Pin 1 gt Pin 13 Pin 1 Pin 13 Dmg e S e Pin 14 f Pin 25 Pin a S Pin 25 25 position D sub plug with screw locks 25 position D sub plug with screw locks ground shield connected to backshell ground shield connected to backshell CAB0061A Industry Interface Type RS 232 C Bay Networks Termination Modem Termination Signal Pin to Pin Signal Chassis Ground 1 1 Chassis Ground Transmit Data 2 2 Transmit Data Receive Data 3 3 Receive Data Request to Send 4 4 Request to Send Clear to Send 5 5 Clear to Send Data Set Ready 6 6 Data Set Ready Signal Ground 7 7 Signal Ground Data Carrier Detect 8 8 Data Carrier Detect Data Terminal Ready 20 20 Data Terminal Ready 117339 A R
125. ssceeeeeeeeesteeeeeeees 5 22 MCE1 DB9 to DB15 Crossover Cable Order No 7168 c cccceceeeeeseeeeeeeeeeeteeeseaees 5 23 T1 to CSU DTE Order No 7401 ccc icteccececesaicecstaasenveratniaias asie RR 5 24 T1 to Customer Premise Equipment Order No 7415 a E P E 5 25 CSU Network Receptacle to RJ 45 Order No 7650 ccceccccssecceessesteeeeesesteeeeeeeaes 5 26 CSU Network Receptacle to Spade Terminals PROTOS No ESO sereni E ies testa aia tase AE susie natin 5 27 Chapter 6 Standard Synchronous Cables 15 Pin to F X 21 Synchronous Pass through Order No AA0018003 A EET re behets eee rakei 6 4 44 Pin F X 21 Synchronous Pass through Ces e eTe a EE AT E A A A E EE AOE TE 6 6 50 Pin to F X 21 Synchronous Pass through Tis AE E e n a a PE TE E E A A A asin sess E E E EE 6 8 15 Pin to RS 530 Straight through Order No AA0018011 E E ET 6 10 44 Pin to RS 530 Straight through Order No AA0018012 o s 6 12 50 Pin to RS 530 Straight through Order No AAQ018013 ceeeceeeeeeeeeteeteeeeeeeeee 6 14 50 Pin t V 28 Cable Order No AAQ0T802J cissciecccessustecciantepeiscecdaressaccamivacceteanrieanrines 6 16 ASSP int to V35M Order No 7158 sesiinosansini DOKII TENS aR SA AAE ineluts 6 17 42 Pinto V3oM Order Na 2 USS ecrcunnnnn P eugene 6 18 15 Pin D Sub to V 35 No DTR for WAN Order No FEUD nnna 6 20 15 Pin D Sub to V 35 with DTR Order No 7216 sa ossiisosinneniinii ianei 6 22 RS 232 Pass throug
126. sub plug with locking posts ground shield connected to backshell Industry Interface Type V 35 V 10 and V 11 15 ft 4 57 m 34 position V 35 plug with screw jack retainers ground shield connected to backshell CAB0007A Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 B Signal Ground Send Data 2 P Send Data A Send Data 3 S Send Data B Serial Clock Transmit 4 Y Send Timing A Serial Clock Transmit 5 AA Send Timing B Request to Send 6 C Request to Send Clear to Send 8 D Clear to Send Data Carrier Detect 10 E Data Set Ready Serial Clock Receive 11 X Receive Timing B Serial Clock Receive 12 V Receive Timing A Receive Data 13 T Receive Data B Receive Data 14 R Receive Data A Internal Wire Connections Pini gt 7 gt 9 Pin C gt H Data Terminal Ready 117339 A Rev A Cable Guide 15 Pin D Sub to V 35 Raise DTR Order No 7121 o 15 ft 4 57 m Pin 1 Pin 8 edi s Pin 9 Pin 15 15 position D sub plug with locking posts ground shield connected to backshell 34 position V 35 plug with screw jack retainers ground shield connected to backshell CABO008A Industry Interface Type V 35 V 10 and V 11 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Sign
127. sub plug with locking posts o f ground shield connected to backshell 25 position D sub plug with screw locks ground shield connected to backshell CAB0045A Industry Interface Type RS 232 C Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 7 Signal Ground Transmitted Data 2 2 Transmitted Data Transmitter Signal Element Timing 3 24 Transmitter Signal Element Timing DTE Source DTE Source Transmitter Signal Element 4 15 Transmitter Signal Element Timing DCE Source Timing DCE Source Request to Send 6 4 Request to Send Clear to Send 8 5 Clear to Send Carrier Detect 10 8 Carrier Detect Receiver Signal Element 12 17 Receiver Signal Element Timing DCE Source Timing DCE Source Received Data 14 3 Received Data Data Set Ready 15 6 Data Set Ready Internal Wire Connections Pini gt 7 gt 9 Pin 4 gt 20 6 30 117339 A Rev A Standard Synchronous Cables 15 Pin D Sub to V 28 Order No 7256 gt 4 57 m Pin 1 Pin 8 Pin 1 _ F Pin 13 jew Hoenn rel T lt S COUUUNN OS ee ee Pin 9 Pin 15 ry ES Pinas 15 position D sub plug with locking posts i ground shield connected to backshell 25 position D sub plug with M 3 jack screws ground shield connected to backshell CABO0045B Industry Inte
128. t 10 11 Data Mode A Serial Clock Receive 11 26 Receive Timing B Serial Clock Receive 12 8 Receive Timing A Receive Data 13 24 Receive Data B Receive Data 14 6 Receive Data A Request to Send 15 25 Request to Send B Internal Wire Connections Pin 7 gt 12 Terminal Ready A Pin 25 gt 30 Terminal Ready B Note You must move Jumpers B and C to the X 21 2 3 position to support this interface 7 4 117339 A Rev A Dialup Services Cables 15 Pin D Sub to RS 422 Raise DTR Order No 7117 Pi G EE ns nex AAT end lt 1 Pin 19 MOORA e SA g e e e AAANAANANANDAAAAA Pin 20 Pin 37 15 position D sub plug with locking posts 37 position D sub plug with screw locks ground shield connected to backshell ground shield connected to backshell CAB0004A Industry Interface Type RS 449 RS 422 117339 A Rev A 7 5 Cable Guide Bay Networks Termination Remote Termination Signal Pin to Pin Signal Signal Ground 1 37 Send Ground Send Data 2 4 Send Data A Send Data 3 22 Send Data B Serial Clock Transmit 4 5 Send Timing A Serial Clock Transmit 5 23 Send Timing B Request to Send 6 7 Request to Send A Clear to Send 7 29 Data Mode B Clear to Send 8 11 Data Mode A Data Carrier Detect 10 15 Incoming Call Serial Clock Receive 11 26 Receive Timing B
129. tect Send Timing 10 10 Send Timing Send Timing 35 24 Send Timing Receive Timing 11 11 Receive Timing Receive Timing 36 25 Receive Timing Transmitter Timing 12 12 Transmitter Timing Transmitter Timing 37 26 Transmitter Timing RTIN 13 13 RTIN RTINB 38 28 RTINB Clear to Send 14 14 Clear to Send CTSIN 39 29 CTSIN RTS 15 15 RTS ST 40 30 ST V 35 Send Timing 16 31 V 35 Send Timing 8 12 117339 A Rev A Cable Adapters Bay Networks 50 Pin Termination Bay Networks 44 Pin Termination Signal Pin to Pin Signal V 35 Send Timing 41 32 V 35 Send Timing V 35 Receive Timing 17 33 V 35 Receive Timing V 35 Receive Timing 42 34 V 35 Receive Timing V 35 Receive Data 18 35 V 35 Receive Data V 35 Receive Data 43 37 V 35 Receive Data V 35 Send Data 19 36 V 35 Send Data V 35 Send Data 44 38 V 35 Send Data V 35 Transmitter Timing 20 39 V 35 Transmitter Timing V 35 Transmitter Timing 45 40 V 35 Transmitter Timing UNBE 46 41 UNBE V35D 47 42 V35D Ground 48 43 Ground Send Common 49 44 Send Common 117339 A Rev A 8 13 Cable Guide 50 Pin to 15 Pin V 35 Cable Adapter Order No 7948 Note This adapter cable allows you to connect an existing 15 pin V 35 cable Order No 7215 or 7216 to a 50 pin port The V 35 interface is automatically selected Su w
130. to make changes to the products described in this document without notice Bay Networks Inc does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein 117339 A Rev A USA Requirements Only Federal Communications Commission FCC Compliance Notice Radio Frequency Notice Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense Federal Communications Commission FCC Compliance Notice Radio Frequency Notice This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to
131. tware to facilitate interoperability Licensee agrees to notify Bay Networks of any such intended examination of the Software and may procure support and assistance from Bay Networks 7 Term and termination This license is effective until terminated however all of the restrictions with respect to Bay Networks copyright in the Software and user manuals will cease being effective at the date of expiration of the Bay Networks copyright those restrictions relating to use and disclosure of Bay Networks confidential information shall continue in effect Licensee may terminate this license at any time The license will automatically terminate if Licensee fails to comply with any of the terms and conditions of the license Upon termination for any reason Licensee will immediately destroy or return to Bay Networks the Software user manuals and all copies Bay Networks is not liable to Licensee for damages in any form solely by reason of the termination of this license 8 Export and Re export Licensee agrees not to export directly or indirectly the Software or related technical data or information without first obtaining any required export licenses or other governmental approvals Without limiting the foregoing Licensee on behalf of itself and its subsidiaries and affiliates agrees that it will not without first obtaining all export licenses and approvals required by the U S Government i export re export transfer or divert any such Softwar
132. urs ne doivent pas proc der ces raccordements eux m mes mais doivent plut t faire appel aux pouvoirs de r glementation en cause ou un lectricien selon le cas Avis Veuillez prendre note que pour tout appareillage supportant des lignes de type loopstart vous pouvez utiliser le Ringer Equivalence Number REN attribu 4 chaque terminal pour d terminer le nombre maximal de terminaux qui peuvent tre branch s votre interface de t l phones Le raccordement l interface pourra se composer de toute combinaison de terminaux pour autant que la somme des RENs ne d passe pas cing Le REN figure sur 1 tiquette FCC Rules Part 68 situ e sur le support du module ou l arri re de l unit 117339 A Rev A vii FCC Part 68 Compliance Statement This equipment complies with Part 68 of FCC Rules All direct connections to telephone network lines must be made using standard plugs and jacks compliant with FCC Part 68 Please note the following 1 You are required to request service from the telephone company before you connect the unit to a network When you request service you must provide the telephone company with the following data e When you request T1 Service you must provide the telephone company with The Facility Interface Code Provide the telephone company with all the codes below 04DU9 BN 1 544 MB D4 framing format 04DU9 DN 1 544 MB D4 framing format with B8ZF coding 04DU9 1KN
133. ustry specification standard or recommendation designated in the Industry Interface Type entry for that cable located immediately following the cable pinout diagram Pinouts for each connector and all associated signals Wire jumper identification for each connector when applicable For example the Sync to V 35 cable Order No 7215 lists internal wire connections Pin 1 gt 7 in the Bay Networks Termination column This indicates that you must connect pin 1 to pin 7 inside the Bay Networks connector Grounding arrangements that isolate the chassis from the DC ground within the cable 117339 A Rev A 6 3 Cable Guide 15 Pin to F X 21 Synchronous Pass through Order No AA0018003 ee 15 position D sub plug with locking posts ground shield connected to backshell Industry Interface Type X 21 aes E Pin 8 Z Pin 1 Q Nese ee ae Pin 15 Pin 9 15 position D sub receptacle with M 3 screw posts ground shield connected to backshell CAB0089A 6 4 117339 A Rev A Standard Synchronous Cables Bay Networks Termination Remote Termination Signal Pin to Pin Signal Transmit Data 2 4 Receive Data A Transmit Data 3 11 Receive Data B Timing 4 6 Timing A Timing 5 13 Timing B Request to Send 6 5 Indication A Data Carrier Detect 9 10 Control B Data Carrier Detect 10 3 Control A Receive Data 13 Tr
134. ve Jumpers A E to the X 21 2 3 position to support this interface 6 28 117339 A Rev A Standard Synchronous Cables 44 Pin D Sub to X 21 Order No 7224 o 15 ft j 4 57 m SS so lo ATO Pes Tal oy AN Pin 16 Cc EEE SST mee Pin 9 se Pin 15 Pin 31 J Pin 44 44 position D sub plug with screw locks 15 position D sub plug with M 3 jack screws ground shield connected to backshell ground shield connected to backshell CABO0104A Industry Interface Type X 21 V 11 Bay Networks Termination Remote Termination Signal Pin to Pin Signal Send Data 2 2 Transmitted Data A Send Data 16 9 Transmitted Data B Request to Send 4 3 Control A Request to Send 18 10 Control B Receive Data 3 4 Receive Data A Receive Data 17 11 Receive Data B Data Carrier Detect 9 5 Indication A Data Carrier Detect 23 12 Indication B Send Timing 10 6 Timing A Send Timing 24 13 Timing B Signal Ground 7 8 Signal Ground Frame Ground 1 1 Frame Ground Internal Wire Connections Pin 14 gt 15 Pin 28 gt 30 Pin 41 gt 43 117339 A Rev A 6 29 Cable Guide 15 Pin D Sub to RS 232 Order No 7255 i __ 15 ft BE 4 57 m _ a N To a n Pin gt Pin 13 ONY o e TN o ong a BE 15 position D
135. ve Tip 2 5 Transmit Tip 117339 A Rev A 5 13 Cable Guide MCT1 Crossover Cable Order No 7153 pan 15 ft 4 57 m oo 5 B Pin 1 se Pin 8 x n 1 IANN rej iit ce LI Pin 15 15 position D sub plug with locking posts RJ 48 connector ground shield connected to backshell CAB0025A Industry Interface Type T1 DS1 Bay Networks Termination A Bay Networks Termination B Signal Pin to Pin Signal Transmit Tip 1 2 Receive Tip Receive Tip 5 Transmit Tip Transmit Ring 1 Receive Ring Receive Ring 11 4 Transmit Ring 5 14 117339 A Rev A E1 T1 Cables MCT1 Loopback Cable Order No 7154 amp Pin 8 Pin 1 Si RJ 48 connector Industry Interface Type T1 DS1 15 ft 4 57 m Pin 8 Pin 1 im RJ 48 connector CAB0026A Bay Networks Termination Remote Termination Signal Pin to Pin Signal Receive Ring 1 4 Transmit Ring Receive Tip 2 5 Transmit Tip Transmit Ring 4 1 Receive Ring Transmit Tip 5 2 Receive Tip 117339 A Rev A 5 15 Cable Guide MCT1 Loopback Cable Order No 7155 15 ft 4 57 m Pin 1 Pin 8 Pin 1 yy Pin 8 A r A Jo AN Jo ANV o MOOOAR N ina e ERNE aae e ee E 15 position D sub plug with locking posts 15 po
136. y Interface Type E1 Bay Networks Termination Remote Termination Signal Pin to Wire Color Signal Receive Tip 1 White BI Receive Tip ue Receive Ring 6 Blue Whi Receive Ring te Transmit Tip 5 White Or Transmit Tip ange Transmit Ring 9 Orange Transmit Ring White Ground 3 Bare Ground 117339 A Rev A 5 5 Cable Guide Quad MCT1 Cable Order No AA0018006 Note You can use this cable assembly with COM 1 ports only 6 in 4 0 15 m z Pin 5 Pin 1 ue 7 ins oe Pin ead Rl 00000000 e TANS ooo ooon e R o Pin 9 Pin 15 Pin 15 Ping _ 7 Pin 9 Pin6 Bay Networks termination Remote termination e 15 position D sub plug 15 position D sub External T1 timing source i i p 9 position D sub with locking posts receptacle with screw locks receptacle with screw locks ground shield connected ground shield connected ground shield connected to backshell to backshell grou to backshell CAB0092A Industry Interface Type T1 DS1 with External Clock Input from an External T1 Timing Source Bay Networks Termination Remote Termination Signal Pin to Pin Signal Transmit Tip 1 1 2 1 Transmit Tip Transmit Ring 1 9 2 9 Transmit Ring Receive Tip 1 3 2 3 Receive Tip Receive Ring 1 11 2 11 Receive Ring EXT Tip 1 7 3 2 EXT Tip EXT Ring 1 15 3 3 EXT Ring Ground 1 2 1 4 Ground Ground 2 2
137. you disconnect the unit from the network 117339 A Rev A Bay Networks Inc Software License Agreement NOTICE Please carefully read this license agreement before copying or using the accompanying software or installing the hardware unit with pre enabled software each of which is referred to as Software in this Agreement BY COPYING OR USING THE SOFTWARE YOU ACCEPT ALL OF THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT THE TERMS EXPRESSED IN THIS AGREEMENT ARE THE ONLY TERMS UNDER WHICH BAY NETWORKS WILL PERMIT YOU TO USE THE SOFTWARE If you do not accept these terms and conditions return the product unused and in the original shipping container within 30 days of purchase to obtain a credit for the full purchase price 1 License Grant Bay Networks Inc Bay Networks grants the end user of the Software Licensee a personal nonexclusive nontransferable license a to use the Software either on a single computer or if applicable on a single authorized device identified by host ID for which it was originally acquired b to copy the Software solely for backup purposes in support of authorized use of the Software and c to use and copy the associated user manual solely in support of authorized use of the Software by Licensee This license applies to the Software only and does not extend to Bay Networks Agent software or other Bay Networks software products Bay Networks Agent software or other Bay Networks software