Home

Avaya Business Communications Manager 450 1.0 Installation Manual

image

Contents

1. Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 114 Analog device spe Copyright 2006 2009 Nortel Networks LED indicators reference This chapter describes the BCM450 system LEDs including BCM450 main unit expansion cabinet and media bay module MBM LEDs Navigation e System status monitor LEDs page 115 e Hard disk drive LEDs page 117 e LAN port LEDs page 117 e DTM LEDs page 119 e BRIM LEDs page 121 System status monitor LEDs You can view the system status LEDs on the faceplate and on the top of the main unit see Figure 21 Location of system status LEDs on a main unit page 116 For details The bottom LED is the power LED and the top LED is the status LED Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 116 LED indicators reference Figure 21 Location of system status LEDs on a main unit Status LED Power LED For details about the meaning of the system status LEDs after the system boots up and is in service see Table 6 System status LEDs states and descriptions page 116 Table 6 System status LEDs states and descriptions Power Status Description LED states seen during Start up sequence Solid yellow Solid yellow Power applied t
2. 2 Order the required trunks from the central office 3 Ensure that the system complies with the environmental requirements 4 Ensure that the system complies with the electrical requirements Ensure that the system complies with the site telephony wiring requirements End Verifying the main unit components Before you install the BCM450 main unit verify that you have the required components and that the components are not damaged Procedure steps Step Action Open the BCM450 main unit box and remove the components Verify that you have one BCM450 main unit Verify that you have one power supply cable Verify that you have four rubber feet Verify that you have one set of rack mount brackets Verify that you have a documentation CD Verify that you have the Installation Checklist and Quick Start Guide Visually inspect the components for damage during shipping OO M OO a BB ND If you find damage or if you do not have all components contact your Nortel sales representative End Verifying the expansion cabinet components Before you install the optional BCM450 expansion cabinet verify that you have the required components and that they are not damaged Procedure steps Step Action Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 20 BCM450 installation prepar
3. Receive Ring Receive Tip Receive Shield Transmit Ring Transmit Tip Transmit Shield No connection DO N O O A W ND No connection BRIM wiring chart The digital BRI ISDN lines connects to the BRIM through the RJ 45 jacks on the front of the media bay module MBM For a view of the BRIM ports see Figure 27 BRIM RJ 45 ports page 133 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Wiring charts reference 133 Figure 27 BRIM RJ 45 ports ISDN BRI S T Interface POE Loop 2 Loop 3 12345678 Power Status RJ 45 pin out RJ 45 jacks Attention For a U loop connection you must connect the BRIM only to an NT1 supplied by the service provider The NT1 must provide a Telecommunication Network Voltage TNV to Safety Extra Low Voltage SELV barrier Table 18 BRIM RJ 45 port wiring Pin Signal Signal on system side 1 No connection No connection 2 No connection No connection 3 Receive Rx TX 4 Transmit Tx Rx 5 Transmit Tx Rx 6 Receive Rx Tx 7 No connection No connection 8 No connection No connection ADID wiring chart Analog telephone lines connect to the ADID4 or ADID8 through the RJ 21 connector on the front of the media bay module MBM To view the ADID connector Figure 28 ADID RJ 21 connector page 134 Nortel
4. DTM see Digital trunk media bay module on page 41 BRIM see Basic rate interface media bay module on page 42 GATM4 GATM8 see Global Analog Trunk Module on page 42 Connects digital public switched telephone lines to the BCM450 1 0 system Can connect to T1 or PRI E1 T1 interfaces Connects a maximum of four ISDN BRI S T interfaces Connects either four GATM4 or eight GATMB8 analog public switched telephone lines to the BCM450 1 0 system Nortel Business Communications Manager 450 1 0 Copyright 2006 2009 Nortel Networks Installation System NN40160 301 01 04 Standard July 2009 124 System information and tools Module type Function Notes ADID4 ADID8 Connects either four ADID4 or see Analog direct inward dialing eight ABIDE analog DID interfaces media bay module on page 43 R2MFC Provides MFC R2 connectivity For details about the R2MFC over an E1 trunk MBM see the R2MFC Media Bay Module Installation and Configuration Guide NN40010 300 Station MBMs connect telephones and analog telecommunication devices to the BCM450 system For a list of the available station media bay modules see Table 12 Station MBMs page 124 Table 12 Station MBMs 1 of 2 Module type Function Notes DSM16 DSM32 Connects a maximum of 16 DSM16 or 32 DSM32 digital telephones to see Digital station the BCM450 system media bay module
5. System Copyright 2006 2009 Nortel Networks NN40160 301 July 01 04 Standard 2009 112 Analog device specifications Table 5 ATA2 ASM8 ASM8 GASM and GASI analog device specifications 2 of 3 Specification ATA2 ASM8 ASM8 GASM GASI ATA2 to 135 ohms N A N A N A N A BCM50 loop 800 m of 0 5 resistance mm wire or cable only 2600 ft of 24 AWG wire Analog loop 1300 ohms 250 ohms 200 ohms 200 ohms 200 ohms resistance on 7200 m of 0 5 1538 m of 0 5 1231 m of 0 5 1231 mof0 5 1231 m of terminal side mm wire or mm wire or mm wire or 4000 mm wire or 4000 0 5 mm for voice 26000 ft of 24 5000 ft of 24 ft of 24 AWG ft of 24 AWG wire or 4000 applications AWG wire AWG wire wire wire ft of 24 cable only AWG wire Analog loop 200 ohms 250 ohms 200 ohms 200 ohms 200 ohms resistance on 1231 m of 0 5 1538 m of 0 5 1231 m of 0 5 1231 mof0 5 1231 m of terminal side mm wire or mm wire or mm wire or 4000 mm wire or 4000 0 5 mm for data 4000 ft of 24 5000 ft of 24 ft of 24 AWG ft of 24 AWG wire or 4000 applications AWG wire AWG wire wire wire ft of 24 cable only AWG wire Input 600 ohms 600 ohms 600 ohms 600 ohms 600 ohms impedance at tip and ring Return loss gt 20 dB for 200 gt 20 dB for 200 gt 20 dB for 200 to gt 20 dB for 200 to gt 20 dB for to 3400 Hz to 3400 Hz 3400 Hz when 3400 Hz when 200 to 3400 w
6. Connect your BCM450 main unit to the LAN to enable LAN access for your system Prerequisites e Obtain a standard Ethernet cable e The DHCP server on the main unit is enabled IP Phones only by default If your network already contains a DHCP server disable the DHCP server on the main unit Procedure steps Step Action 1 Connect one end of a standard Ethernet cable to your LAN 2 Plug the other end of the Ethernet cable into one of the available two LAN ports on the BCM450 main unit two right most ethernet ports The OAM port does not support VoIP devices End Connecting IP devices to the LAN Connect IP devices to the LAN to provide additional functionality to your BCM450 system Prerequisites e Obtain a standard Ethernet cable for each IP device e A properly configured layer 2 switch in the network CAUTION The two LAN ports on the BCM450 are set up in a bridge configuration both ports use the same IP address Do not connect IP devices to both ports at the same time to avoid service problems Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks LAN connection 77 Procedure steps Step Action 1 Connect one end of a standard Ethernet cable to an IP device 2 Connect the other end of the Ethernet cable into one an available ports on the layer 2 switch Connect the sw
7. Copyright 2006 2009 Nortel Networks 12 Introduction e Auxiliary equipment connection page 69 e LAN connection page 75 e BCM450 telephone and peripheral installation page 79 e Capacity expansion card installation page 83 e Analog terminal adapter installation page 85 e Element Manager installation page 91 e BCM450 common procedures page 95 e Preinstallation reference page 103 e GASM DIP switch configuration page 107 e Ports and connectors reference page 109 e Analog device specifications page 111 e LED indicators reference page 115 e System information and tools page 123 e Default values reference page 129 e Wiring charts reference page 131 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Installation architecture This chapter describes the architecture of a typical Business Communications Manager 450 BCM450 system including the main unit expansion cabinets and related equipment The mounting options for your BCM450 system and the DHCP details are also discussed Navigation e System architecture page 13 e DHCP and IP addressing page 14 e Mounting options page 15 e Miscellaneous features page 16 e Line and data connector wiring page 16 System architecture The primary hardware component of your BCM450 system is the main unit Each BCM450 system must hav
8. The R2MFC MBM is a media bay module MBM that provides MFC R2 connectivity over an E1 trunk The module works as a converter between Euro ISDN and MFC R2 protocols to allow the MFC R2 protocol E1 to work directly with the BCM without the use of an external converter The BCM recognizes the converter as a Euro ISDN trunk MBM and therefore provides all of the functionality on the MFC R2 E1 that is available on a Euro ISDN E1 The MFC R2 trunk is controlled by DIP switches and the Command Line Interface CLI on the R2MFC MBM Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 54 MBM installation For instructions to install configure and maintain the R2MFC MBM see R2MFC Media Bay Module Installation and Configuration Guide NN40010 300 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks BCM450 cable connection This chapter describes how to connect the lines extensions and auxiliary equipment to your BCM450 system It also describes how to connect the BCM450 system to a LAN BCM450 cable connection tasks This work flow shows you the sequence of tasks you perform to install a main unit and expansion cabinet To link to any tasks go to BCM450 cable connection navigation Nortel Business Communications Manager 45
9. into the BCM450 main unit The CEC provides increased media processing capacity to support up to 300 stations and 130 trunks as well as the associated increases in application capacity Installing the CEC Use the following procedure to install the CEC in the main unit Prerequisites e Power down the BCM450 system e You will require a Phillips head screwdriver e Ensure the BCM450 main unit is disconnected from the AC power source CAUTION Risk of damage to equipment You must wear an antistatic grounding strap at all times when handling electronic components Failure to do so can result in damage to the equipment Step Action Power down the BCM 450 system and remove the base function tray 2 Attach one end of a grounding strap to your wrist and the other end to a grounded metal surface 3 Remove the plastic cap on the CEC slot on the front of the base function tray by applying pressure to the bottom of the faceplate from the inside of the Base Function tray Once the bottom has come loose remove the faceplate from the front Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 84 Capacity expansion card installation Figure 15 CEC slot CEC slot 4 Screw the four metal standoffs included into the main board of the base function tray 5 Slide the CEC into position from the bac
10. 2 Plug the other end of the USB cable into the top USB port on the BCM450 main unit This ensures that the bottom port is left available for a USB storage device 3 Plug the UPS power cord into the AC power source wall outlet Main unit USB Cable End Connecting the BCM450 system to a power source To power your BCM450 system connect the main unit and expansion cabinet to an AC power source You can connect the power supplies through a UPS or directly to the AC power source Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Power connection 61 Prerequisites e Locate the supplied power cord the main unit and optional expansion cabinet e The power supply must be within 1 5 m 5 ft of the BCM450 unit and within 1 5 m 5 ft of the AC power outlet Procedure steps Step Action 1 Connect the BCM450 main or expansion cabinet power cord to a non switchable third wire ground AC electrical outlet 2 If you use a power bar connect the power cord to the power bar and connect the power bar to the outlet End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 62 Power c Copyright 2006 2009 Nortel Networks Lines and extensions connection The telephone lines an
11. 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Copyright 2006 2009 Nortel Networks Introduction This guide describes how to install the Business Communications Manager 450 Release 1 0 BCM450 1 0 system The concepts operations and tasks described in this guide relate to the BCM450 system This guide provides task based information to install the hardware components The BCM450 1 0 provides private network and telephony management capability to small and medium sized businesses The BCM450 system Navigation integrates voice and data capabilities and IP Telephony gateway functions into a single telephony system provides telephony applications for use in a business environment Installation architecture page 13 BCM450 installation preparation page 17 BCM450 main unit and expansion cabinet installation page 21 BCM450 main unit installation page 25 Installing the BCM450 main unit on a rack page 27 BCM450 main unit wall mount installation page 31 BCM450 main unit desktop installation page 35 BCM450 expansion cabinet installation page 37 MBM installation page 43 BCM450 expansion cabinet installation page 37 BCM450 cable connection page 55 Power connection page 57 Lines and extensions connection page 63 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009
12. Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 134 Wiring charts reference Figure 28 ADID RJ 21 connector RJ 21 connector RJ 21 pin out GATM wiring chart Analog telephone lines connect to the GATM4 or GATM8 through the RJ 21 connector on the front of the media bay module MBM To view the GATM MBM see Figure 29 GATM RJ 21 connector page 134 Figure 29 GATM RJ 21 connector GATM 1 25 eE Power Status 26 50 RJ 21 connector RJ 21 pin out Table 19 GATM4 RJ 21 connector wiring page 134 lists the wiring details for the RJ 21 connector on the GATM4 Table 19 GATM4 RJ 21 connector wiring Line Pin Connection Wire color 1 26 Tip White Blue 1 Ring Blue White 2 27 Tip White Orange 2 Ring Orange White 28 No connection White Green 3 No connection Green White Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Wiring charts reference 135 Table 19 GATM4 RJ 21 connector wiring Line Pin Connection Wire color 29 No connection White Brown 4 No connection Brown White 3 30 Tip White Slate 5 Ring Slate White 4 31 Tip Red Blue 6 Ring Blue Red 32 No Connection Red Orange 7 No Connection Orange Red 49 No Connection Violet Brown 24 No Connection Brown Violet AUX
13. F9 8 and F Config Telset SETNNA CONFIG Administration 738662 266344 voice mail Feature 983 Telset CONFIG Administration 266344 initialize voice mail Feature 983 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 130 Default values r Copyright 2006 2009 Nortel Networks Wiring charts reference This chapter provides the wiring information for the BCM450 system connectors and ports Navigation DTM wiring chart page 131 BRIM wiring chart page 132 ADID wiring chart page 133 GATM wiring chart page 134 4x16 wiring chart page 137 G4x16 and G8x16 wiring chart page 137 DSM16 and DSM32 wiring chart page 138 ASMB8 ASM8 and GASM wiring chart page 139 DTM wiring chart The digital telephone line connects to the Digital Trunk Module DTM through the RJ 48c jack on the front of the media bay module MBM For a view of the DTM ports see Figure 26 DTM RJ 48C port page 132 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 132 Wiring charts reference Figure 26 DTM RJ 48C port TEE O amp 12345678 Oo Oo D D B Le On O Power Status Bantam jack RJ 48C jack RJ 48C pin out Table 17 DTM RJ 48c port wiring Pin Signal
14. MBMs to the jacks on the FEM a Connect the Norstar Line Modules to the FEM beginning at fiber port 1 b Connect Norstar Extension Modules to the FEM beginning at fiber port 6 3 Change the DN records in Element Manager or change the set wiring as required to match your system Warning When you connect a Norstar Station Module to an FEM the extension numbers of the telephones connected to the Station Module may change To keep the same extension numbers you must change the DNs of the telephones or change the telephone wiring to correspond with the required DNs Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks MBM installation 49 Note If you connect a Norstar station MBM amphenol cable directly to a DSM you do not have to modify the wiring connections Ensure you select the correct DS30 number Table 1 compares the designated extension numbers on the Norstar and on the BCM50 systems Table 1 Extension comparison chart DS30 bus 2 FEM port 1 Norstar 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 BCM 225 226 227 228 221 222 223 224 233 234 235 236 229 230 231 232 DS30 bus 3 FEM port 2 Norstar 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 BCM 241 242 243 244 237 238 239 240 249 250 251
15. System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 28 Installing the BCM450 main unit on a rack Figure 5 Attaching the rack mount bracket ats 7 ECT LE a ie 4 Align the screw holes between the BCM main unit and the left rack mount bracket Fasten the bracket to the main unit using four screws Determine the location in the rack where you want to install the main unit 7 Position the main unit in the rack Have an assistant hold the main unit 8 Align the holes in the rack mount bracket with the holes in the equipment rack rails 9 Fasten the rack mount brackets to the rack using the four supplied rack screws Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Installing the BCM450 main unit on a rack 29 Figure 6 Mounting the BCM450 on a rack a X y KI z a End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks O main unit on a rack Copyright 2006 2009 Nortel Networks BCM450 main unit wall mount installation This chapter describes how to install a BCM450 main unit on a wall To wall mount a BCM450 unit you need a wall mount bracket The BCM450 unit connects to the wall mount bracket Prerequisit
16. a BCM450 unit main unit or expansion cabinet to a wall Uninterruptible power supply UPS An uninterruptible power supply UPS is an optional device that if applicable maintains continuous operation during power interruption or failure conditions The UPS provides power source monitoring and battery backup activation to maintain critical BCM450 functionality BCM450 supports American Power Conversion APC UPS devices that use a USB control interface The UPS control software configures various operational settings Tools Use the following table to view and record the tools required for your BCM450 installation Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 126 System information and tools Table 14 Tools Description Laptop or PC with e Windows 2000 Windows XP or Windows Vista e minimum 256 MB recommended 512 MB e 150 MB free disk space Mounting hardware rack mount brackets wall mount bracket or rubber feet an optional plywood backboard 3 4 in 2 cm thick for wall mount installations Phillips 2 screwdriver Common screwdriver Pliers Antistatic ground strap Connecting tool 25 pair cable with RJ 21 connector Cat 5 Ethernet cable with RJ 45 connectors Surge protector System information Use the following table to view and record the system information for
17. be any available radio or music source approved for connection to the network Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard Copyright 2006 2009 Nortel Networks July 2009 Analog device specifications This chapter provides a comparison of the specifications of the various analog devices available for a BCM450 system ATA2 ASM8 ASM8 GASM and GASI analog device specifications The following table shows the specifications for ATA2 ASM8 ASM8 GASM and GASI Table 5 ATA2 ASM8 ASM8 GASM and GASI analog device specifications 1 of 3 Specification ATA2 ASM8 ASM8 GASM GASI Ringing 20 Hz 1 Hz 20 Hz 1 Hz 20 Hz 1 Hz 20 Hz 1 Hz 20 Hz 1 Hz frequency North America Ringing 25 Hz 1 Hz 25 Hz 1 Hz 25 Hz 1 Hz 25 Hz 1 Hz 25 Hz frequency 1 Hz Europe Ringing 80 V rms 10 55 V rms 10 65 Vrms 10 65 V rms 10 65 Vrms voltage North 10 America Ringing 75 V rms 10 N A 65 Vrms 10 65 V rms 10 65 V rms voltage 10 Europe Loop current 20 mA 20 mA minimum 20 mA minimum 20 mA minimum 20 mA minimum minimum Battery feed 48 V de 10 48 V dc 10 29 V dc 10 48Vdc 10 48Vdc voltage 10 FIC code OL13ABC N A N A N A N A Ringer 3 1 2 2 2 equivalency number Nortel Business Communications Manager 450 1 0 Installation
18. descriptive name for the user or the user function Password Enter a password for this account Telset user ID numeric If the user performs administration through the Telset interface enter a number for the user ID Telset password Enter a password for the Telset User ID numeric Modem Callback Number If Callback is required enter the number to which the system calls back to verify the dial up user access Modem Callback This is the code the system uses to confirm the callback is legitimate Passcode ISDN Callback Number If ISDN Callback is required enter the number to which the system calls back to verify the dial up user access ISDN Callback Passcode This is the code the system uses to confirm that the ISDN callback is legitimate Change Password On Select this check box to force the user to change the password upon Login first login Change Password On Select this check box to force the user to change the Telset password Login Telset upon first log in Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks BCM450 common procedures This chapter describes common procedures for the BCM450 system BCM450 common procedures navigation e Rebooting the BCM450 page 95 e BCM450 shut down page 96 e Installation troubleshooting page 96 Rebooting the BCM450 You can reboot the BCM450 system through Elemen
19. digital loop one two or three twisted pair cables per telephone DC loop resistance of less than 64 Q cable length 0 5 mm or 24 AWG less than 300 m 975 ft use of a station auxiliary power supply SAPS for loops 300 m 975 ft to 1200 m 3900 ft In North America the SAPS must be a CSA or UL Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Preinstallation reference 105 approved Class 2 power source In Europe the SAPS must be a Class II power source and CE marked e no bridge taps Analog loop You must meet the following parameters for an analog loop e maximum DC loop resistance of 208 Q e maximum cable length 0 5 mm or 24 AWG of 1220 m 4000 ft Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 106 Preinstall Copyright 2006 2009 Nortel Networks GASM DIP switch configuration Before you install the GASM in the expansion cabinet or main unit configure the DIP switches to the required positions GASM DIP switch configuration Configure the Module Select DIP switches on the left side at the rear of the GASM to on up as shown in the following figure Configure the Mode Country Select DIP switches on your GASM according to the following tables Figure 19 GASM DIP switch loc
20. line or line pool Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 98 Troubleshooting 9 If this system is connected to an expansion cabinet with an MBM that supports lines repeat steps 6 to 8 with an extension that can access one of the lines connected to the expansion unit End Troubleshooting the main unit If a test fails use the following procedure to troubleshoot the main unit Procedure steps Step Action 1 Verify that no nonfunctional features are included in your installed keycode 2 Check the wiring to the main unit and to the MBMs Make sure that the cables are properly seated and are connected to the correct ports Reboot the BCM450 system Check the LEDs Use Element Manager or the Telset Administration feature to check the programming for the lines or extensions that failed the call test 6 If the programming is incorrect use the Backup and Restore Utility to load a recent backup of system programming If a recent backup is not available correct the programming using Element Manager or the Telephone Administration feature End Testing an MBM Use the following procedure to test an MBM installed in the main unit or expansion cabinet If you are experiencing an issue with an FEM ensure all DIP switches are set to the On position For more information see Fiber expansion
21. main unit by using the screws provided 8 Hang the BCM main unit on the backboard screws Make sure the main unit is level Ensure the wood screw heads seat fully into the wall mount bracket slots 9 Tighten the wood screws against the wall mount bracket End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks mount installation Manager 450 1 0 Copyright 2006 2009 Nortel Networks BCM450 main unit desktop installation This chapter describes how to install a BCM450 main unit on a desktop or other flat surface that can support the weight of the main unit Prerequisites e Locate the four self adhesive rubber feet e Leave enough space around the BCM450 main unit for ventilation and access to the cables Procedure steps Step Action 1 Remove the paper backing from the four enclosed self adhesive rubber feet 2 Attach the four self adhesive rubber feet to the bottom of the main unit 3 Position the main unit on a desktop or shelf End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 36 BCM450 main unit desktop installation Copyright 2006 2009 Nortel Networks BCM450 expansion cabinet installation This chapter describes how to install a BCM450 expan
22. on page 44 4x16 Connects a maximum of four analog Combinati nota public switched telephone lines to the BCM450 system CTM4 and a DSM16 see 4x16 media bay module on page 44 G4x16 G8x16 Connects a maximum of four G4x16 or eight G8x16 analog public switched telephone lines to the BCM450 system Also connects a maximum of 16 digital telephones to the BCM450 system Combination of a GATM4 GATM8 and a DSM16 see G4x16 and G8x16 media bay module on page 45 Also connects a maximum of 16 digital telephones to the BCM450 system Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks System information and tools 125 Table 12 Station MBMs 2 of 2 Module type Function Notes GASM ASM8 Connects a maximum of eight analog see Analog station devices to the BCM450 system media bay modules This module provides the following on page 45 additional services caller ID pass through message waiting indication and disconnect supervision at the telephone This module downloads new firmware Additional hardware In addition to the main unit expansion cabinet and MBMs the BCM450 system includes the additional hardware listed in the following table Table 13 Additional hardware descriptions Hardware Description Wall mount bracket A bracket designed to mount
23. status of the MBM For information about the location of the Power and Status LEDs on an MBM see Figure 23 Media bay module LEDs expansion cabinets only page 119 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks LED indicators reference 119 Figure 23 Media bay module LEDs expansion cabinets only GATM MAI Power Status The power and status LEDs are in the same location on all MBMs For information about the possible MBM LED states see Table 9 Media bay module LEDs expansion cabinets only page 119 Table 9 Media bay module LEDs expansion cabinets only Power Status Description Off Off The MBM has no power or a failure occurred on the MBM power converter On Off MBM failure or system initialization On Blinking Hardware is working but an operational problem exists such as e no link to the main unit is detected e frame alignment is lost on messages from the main unit e bandwidth not allocated e MBM is in maintenance state e MBM is in download state GASM GATM4 GATM8 Blinking Blinking The MBM has power but a hardware problem exists such as e partial failure of power converter e thermal overload e fan failure DTM LEDs The DTM has additional LEDs that are not on most other MBMs For information about the location of the DTM LEDs see Figure 24 DTM LEDs pag
24. the MBM is properly seated in the MBM bay If the Status LED is not solid green and the MBM is installed in the expansion cabinet check that the Expansion cable is properly seated in the Expansion port on the expansion cabinet and on the main unit 6 Ensure that the MBM is enabled using either Element Manager or Telset Administration If the MBM is enabled disable and re enable it 7 Ensure that all DIP switches are set correctly For more information see MBM installation page 43 End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 100 Troubleshooting Troubleshooting the FEM Use the following procedure to troubleshoot an installed fibre expansion module FEM Procedure steps Step Action 1 Ensure that all six connector LEDs are lit 2 If all six LEDs are not lit ensure that all six DIP switches are set to the On up position For more information see Fiber expansion module configuration page 47 End Troubleshooting the ATA2 Use the following procedure to troubleshoot a non functioning ATA2 Step Action 1 Check for a dial tone using an analog device 2 Check that AC power is connected to the ATA2 unit 3 Check that the correct feature for digital sets is included in your installed keycode 4 Verify that the ATA2 is connected to a digital station port Allow
25. the expansion cabinet directly on a wall Prerequisites e A wall mount bracket kit NTAB3422 e Obtain five 8 x 2 cm 8 x 0 75 in round head wood screws to attach the wall mount bracket to the backboard or wall e Obtain tools for the installation including a screwdriver for the wood screws a level and a pencil e You can install a plywood backboard onto the wall to simplify the installation of the expansion cabinet For more information see Mounting the backboard page 32 e Obtain an appropriate screwdriver Step Action Place the wall mount bracket on the backboard or wall and mark the location of the screw holes Use a bubble level to ensure that the wall mount bracket is level with the plywood backboard Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 40 BCM450 expansion cabinet installation 2 Install four 10 x 2 5 cm 10 x 1 in round head screws in the backboard Leave approximately 0 5 cm 0 25 in of each screw exposed from the backboard or wall 3 Hang the wall mount bracket on the installed screws 4 Use a level to make sure the wall mount bracket is level 5 Remove the wall mount bracket from the backboard 6 Align the screw holes on one side of the BCM450 expansion cabinet with the wall mount bracket 7 Fasten the wall mount brackets securely to the BCM450 expansion cabine
26. the front of a 4x16 MBM Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 66 Lines and extensions connection e Obtain a telephone cable that includes a modular plug that matches the MBM to which you want to connect RJ 48C for DTM RJ 45 for BRIM RJ 11 for 4x16 and CTM Procedure steps Step Action 1 Plug the modular cable into the jack in the front of the MBM The 4x16 is connected using a 25 pair connector cable 2 Connect the other end of the cable to the telephone company demarcation blocks of the building 3 To connect additional analog lines to a 4x16 MBM or BRIM repeat step 1 and step 2 for each line End Connecting to DSM16 DSM32 ASM8 MBMs You can connect telephones to your BCM450 system through the DSM16 DSM32 ASM8 MBMs Prerequisites e Obtain a 25 pair connector cable with an RJ 21 connector on one end e Do not connect the digital station ports of the DSM16 DSM32 or combination MBMs to the PSTN Only approved digital telephones or peripheral devices can connect to the DSM16 DSM32 and combination MBMs Attention ASM8 does not support digital telephones Procedure steps Step Action 1 If you use the DSM16 DSM32 ASM8 or 4x16 MBM plug the RJ 21 end of the connector cable into the RJ 21 connector on the front of the MBM 2 If you use a
27. to the ATA2 Replace the analog telephone with the test set Use RECEIVE 600 OHM HOLD mode on the test set Ensure that the analog port terminates correctly in 600 ohms a BB N Ensure that the test set connects in parallel to the service line before you remove the analog telephone or the line drops Oo Remove the single line telephone Introduce a 1 KHz tone into the analog line at 10 dBm and measure the level at the CO exchange End Configuring the ATA2 Configure the ATA2 using Element Manager or Telset Administration For detailed configuration information see Norte Business Communications Manager 450 1 0 Configuration Devices NN40160 500 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Copyright 2006 2009 Nortel Networks Element Manager installation This chapter describes how to install Element Manager for the BCM450 Prerequisites to Element Manager installation e Ensure that the BCM450 is correctly installed powered up and connected to the network Element Manager installation procedures This task flow shows you the sequence of procedures you perform to install Element Manager To link to any procedures go to Element Manager installation procedures navigation Figure 17 Element Manager installation procedures Dowloading and installing Bement lvianager Connec
28. your BCM450 installation Table 15 System information 1 of 2 Description System name Date and Time NTP Trunk Manual Time zone Initial IP address and netmask the network interface Default next hop router default gateway DHCP server DNS domain name Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks System information and tools 127 Table 15 System information 2 of 2 Description Primary and optional secondary DNS servers IP Profile region Telephony Startup template DID PBX Start DN Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 128 and tools Copyright 2006 2009 Nortel Networks Default values reference Use the following tables to view default values for your BCM450 system and to record the new values Navigation e Default user names and passwords page 129 Default user names and passwords Use the following table to view and record changes to the default user names and passwords Table 16 Default user names and passwords Tool User ID User name Password New password Element nnadmin PlsChgMe Manager BCM450 Web nnadmin PlsChgMe page http IP address Telset SETNNA CONFIG Administration 738662 266344
29. 0 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 56 BCM450 cable connection Figure 10 BCM450 cable connection tasks Power connection Lines and extensions connections Fuxiliary equipment connection Fauxiliary equipment LAN connection No Yes No BCM450 cable connection navigation e Power connection page 57 e Lines and extensions connection page 63 e Auxiliary equipment connection page 69 e LAN connection page 75 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Power connection The BCM main unit and expansion cabinet are each powered through an AC outlet The voltage required depends on the geographical location of the units All systems are initially configured at the factory based on the intended destination You must check that the voltage and wiring are correct for your system before you connect the units to the power source Incorrect power settings result in equipment damage Read the following warnings You must protect yourself and the BCM system from possible electrical shocks DANGER Risk of injury from electric shock Connect the ports on station modules only to approved digital telephones and peripherals with the proper cables on a protected internal wiring system CAUTION Use only qua
30. 252 245 246 247 248 DS30 bus 4 FEM port 3 Norstar 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 BCM 257 258 259 260 253 254 255 256 265 266 267 268 261 262 263 264 DS30 bus 5 FEM port 4 Norstar 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 BCM 273 274 275 276 269 270 271 272 281 282 283 284 277 278 279 280 DS30 bus 6 FEM port 5 Norstar 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 BCM 289 290 291 292 285 286 287 288 297 298 299 300 293 294 295 296 DS30 bus 7 FEM port 6 Norstar 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 BCM 305 306 307 308 301 302 303 304 313 314 315 316 309 310 311 312 Configuring the MBM DIP switches for main unit installation Before you install the MBM into the main unit configure the DIP switches to the default factory positions Procedure steps Step Action Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 50 MBM installation 1 Locate the DIP switches at the rear or underside of the MBM x Underside of MBM Eu e 654321 it
31. 450 main unit on a rack 27 BCM450 main unit wall mount installation Mounting the backboard 32 Installing the main unit using a wall mount bracket 33 31 BCM450 main unit desktop installation 35 BCM450 expansion cabinet installation BCM450 expansion cabinet installation navigation 38 Mounting the expansion cabinet in an equipment rack 38 Installing the expansion cabinet on a wall 39 Installing the expansion cabinet on a desktop 40 Connecting the expansion cabinet to the main unit 41 37 MBM installation Configuring the G4x16 or G8x16 DIP switches 45 Configuring the GASM DIP switches 46 Configuring the GATM DIP switches 46 Fiber expansion module configuration 47 Wiring the FEM 47 Configuring MBMs for main unit installation 50 Configuring MBMs for expansion cabinet installation 51 Installing an MBM in the main unit or an expansion cabinet 52 Prerequisites 52 R2MFC MBM installation 53 43 BCM450 cable connection 55 Power connection Connecting a UPS to your BCM450 system 60 Connecting the BCM450 system to a power source 60 57 Lines and extensions connection Connecting to GATM4 GATM8 and G4x16 8x16 MBMs 65 Connecting to DTM BRIM CTM and 4x16 MBMs 65 Connecting to DSM16 DSM32 ASM8 MBMs 66 63 Auxiliary equipment connection Connecting an auxiliary ringer 71 Connecting an external paging system 72 Connecting the music source using the music source jack 72 Procedure st
32. 50 Tip Violet Slate 25 Ring Slate Violet Note The Aux port supports full data speeds When the line is in use by an analog device the icon is lit on the phone to indicate it is in use If you try to seize the line using the phone the display shows in use Also in the event of a power failure an analog set on line 1 goes active powered by the CO Table 20 GATM8 RJ 21 connector wiring page 135 lists the wiring details for the RJ 21 connector on the GATM8 Table 20 GATM8 RJ 21 connector wiring Line Pin Connection Wire color 1 26 Tip White Blue 1 Ring Blue White 2 27 Tip White Orange 2 Ring Orange White 28 No connection White Green 3 No connection Green White Copyright 2006 2009 Nortel Networks Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 136 Wiring charts reference Line Pin Connection Wire color 29 No connection White Brown 4 No connection Brown White 3 30 Tip White Slate 5 Ring Slate White 4 31 Tip Red Blue 6 Ring Blue Red 32 No connection Red Orange 7 No connection Orange Red 33 No connection Red Green 8 No connection Green Red 5 34 Tip Red Brown 9 Ring Brown Red 6 35 Tip Red Slate 10 Ring Slate Red 36 No connection Black Blue 11 No connection Blue Black 37 No connection Black Orange 12 No connection Orange Black 7 38 Tip Black Green 13 Ring Green Black 8 39 Tip Black Green 14
33. External DHCP server available If an external DHCP is present the BCM450 system uses the IP configuration supplied by the external DHCP server Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Installation architecture 15 The DHCP server on the main unit must configure a range of IP addresses to supply to the IP Phones The factory default DHCP server address range is set to 192 168 2 3 192 168 3 254 This allows for more than 500 addresses Use Element Manager to verify and change the default range The administrator must ensure that this range works with the network configuration the external DHCP server does not use the range Mounting options You typically install the main unit and expansion cabinet in the same manner Ensure you install the expansion cabinets close enough to the main unit so you can connect the supplied 5 m 16 ft expansion cable between the expansion cabinet and main unit Nortel provides three methods to install the BCM450 units e Rack mount installation e Wall mount installation e Desktop mount installation Rack mount installation You can install a BCM450 main unit in a standard 19 inch equipment rack along with your other networking and telecommunications equipment You install the BCM450 expansion cabinet in a similar manner to the main unit Wall mount installation You can mount a BCM450 mai
34. M450 system To link to any procedure go to Power supply installation navigation page 59 Nortel Business Communications Manager 450 1 0 Copyright 2006 2009 Nortel Networks Installation System NN40160 301 01 04 Standard July 2009 Power connection 59 Figure 11 BCM450 power connection Connecting a UPS to your BCNH50 system Connecting the BCNHSD to a power source Power supply installation navigation e Connecting a UPS to your BCM450 system page 60 e Connecting the BCM450 system to a power source page 60 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 60 Power connection Connecting a UPS to your BCM450 system To obtain USB communication between an APC UPS and BCM450 a USB hub is not required APC American Power Conversion is the only supported UPS vendor for BCM Prerequisites e For the UPS to function correctly you must connect it before you power up the BCM450 system If you connect a UPS to a running system the UPS does not function e International non North American users require the power supply adapter cord to connect the power supply to the region specific power bar e Ensure the power supply is within 1 5 m 5 ft of the BCM450 unit and within 1 5 m 5 ft of the UPS Procedure steps Step Action 1 Plug one end of the USB cable into the USB port on the UPS
35. NORTEL Installation System Release BCM450 1 0 Document Revision 01 04 NN40160 301 Document status Standard Document issue 01 04 Document date July 2009 Product release BCM450 1 0 Job function Installation Type Document Language type English Copyright 2006 2009 Nortel Networks All Rights Reserved NORTEL the globemark design and the NORTEL corporate logo are trademarks of Nortel Networks Contents New in this release Features 9 Other Changes 9 Revision History 9 Introduction 11 Installation architecture 13 System architecture 13 DHCP and IP addressing 14 External DHCP server not available 14 External DHCP server available 14 Mounting options 15 Rack mount installation 15 Wall mount installation 15 Desktop mount installation 15 Miscellaneous features 16 External music source 16 Analog telephones and devices 16 Element Manager 16 Startup Profile 16 Line and data connector wiring 16 ay BCM450 installation preparation 17 Verifying the site requirements 18 Verifying the main unit components 19 Verifying the expansion cabinet components 19 Preinstallation checklists 20 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 4 Contents BCM450 main unit and expansion cabinet installation 21 BCM450 main unit installation 25 Installing the BCM
36. Ring Green Black 40 No connection Black Slate 15 No connection Slate Black 49 No Connection Violet Brown 24 No Connection Brown Violet Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Wiring charts reference 137 Line Pin Connection Wire color Aux 50 Tip Violet Slate 25 Ring Slate Violet Note The Aux port supports full data speeds When the line is in use by an analog device the icon is lit on the phone to indicate it is in use If you try to seize the line using the phone the display shows in use Also in the event of a power failure an analog set on line 1 goes active powered by the CO 4x16 wiring chart The analog telephones lines connect to the 4x16 through the RJ 11 jacks labeled 1 to 4 on the front of the MBM Do not connect analog telephone lines to the auxiliary jack on the front of the media bay module These jacks are intended for analog telephones designated as emergency telephones To view the 4x16 connectors see Figure 30 4x16 connectors page 137 Figure 30 4x16 connectors RJ 21 connector RJ 21 pin out RJ 11 jacks RJ 11 pin out G4x16 and G8x16 wiring chart You can connect 4 or 8 analog telephone lines and up to 16 digital telephones to the G4x16 or G8x16 media bay module MBM Nortel Business Communications Manager 450 1 0 Installation S
37. ade a Norstar system to a Business Communications Manager system The front bezel of the FEM has six connectors These connections are made using fiber cables between the FEM module and the Norstar expansion modules Beside each connector an LED lights when the fiber port is enabled BCM450 supports one FEM installed in the main unit Ensure that all dip switches are set to the On up position before installing the FEM After the FEM is installed ensure that all six connector LEDs are on Wiring the FEM A fiber expansion module FEM allows you to upgrade from a Norstar system to a BCM50 system by reusing the Norstar MBMs The MBMs connect to the FEM using the same fiber cable that connected them to the Norstar fiber expansion card Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 48 MBM installation Warning Handling optical fiber cables If the cable is too long ensure that it is coiled correctly using the fiber spool Coil excess fiber cable carefully around the spool provided Do not bend the cable around any tight corners Bends in the fiber cable must not be less than 100 mm in diameter Place the fiber cable spool into a slot at the back of the cable trough in the Norstar TM or SM To connect the fiber cables 1 Ensure the BCM50 system is powered up and functional 2 Connect the fiber cables from the Norstar
38. al paging amplifier The contact pair for the page relay output has a switch capacity of 50 mA non inductive at 40 V maximum Procedure steps Step Action 1 Install the external paging hardware using the installation instructions supplied with the external paging system Connect the paging system audio input to the page output connection Connect the paging system relay to the page relay output connection Verify that the external paging system functions properly End Connecting the music source using the music source jack You can use a customer supplied low power device as a music source A music source includes equipment such as a radio with a high impedance earphone jack Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Auxiliary equipment connection 73 Prerequisites e Ensure that the music source follows these guidelines Nominal input impedance is 3 3 kilohms Nominal sensitivity of this interface returned to digital encoded PCM is 22 dBm0 for a 0 25 V rms input signal The input is limited so that the encoded analog content at the digital interface to the network does not exceed 12 dBm when averaged over a three second interval The maximum nonclipped input level is 1 V rms The interface is protected against ringing cross Procedure steps Step Ac
39. anager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 22 BCM450 main unit and expansion cabinet installation Figure 3 BCM450 main unit and expansion cabinet installation tasks Wtain unit installation Expansion cabinet required Expansion cabinet installation MBM required MBM installation BCM450 main unit and expansion cabinet installation navigation e BCM450 main unit installation page 25 e BCM450 expansion cabinet installation page 37 e MBM installation page 43 e BCM450 cable connection page 55 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Nortel Busin r 450 1 0 Copyright 2006 2009 Nortel Networks 24 BCM450 main unit and expansion cabinet installation Copyright 2006 2009 Nortel Networks BCM450 main unit installation This chapter describes how to install a BCM450 main unit You can install the main unit in a standard 19 inch equipment rack on a wall or on a desktop Prerequisites to main unit installation e To operate the BCM450 main unit at the optimal internal temperature ensure the top sides and rear clear of obstructions and away from the exhaust of other equipment e Ensure no objects are on top of the main unit Main unit installation tasks This work flow shows yo
40. and control the UPS functions You must format the USB storage device for the FAT32 file system If necessary reformat the USB storage device by plugging it into a USB port on your computer right clicking the USB device icon and selecting FAT32 reformatting This destroys any data on the USB DS256 jack The BCM expansion cabinet connects to the BCM450 main unit through the DS256 jack on the faceplate The DS256 cable to make this connection is provided with the purchase of a BCM expansion cabinet Auxiliary ringer jack The BCM450 system uses the auxiliary ringer jack to control the cadence of an auxiliary ringer customer supplied You must use this output in a low current low voltage application only Do not use this output to directly switch the auxiliary ringer Page relay jack If you use the page signal output jack to connect an external paging amplifier you also use the page relay jack The page relay jack connects a floating relay contact pair The BCM450 system uses this jack to control the external paging amplifier Page output jack The BCM450 system uses the page output to connect an internally generated voice paging signal to an external paging amplifier customer supplied Music on hold jack The BCM450 system uses the music on hold input to connect an external music source that supplies a signal to held lines music on hold or telephone speakers background music The input source can
41. ation 1 on od a fF DN Open the BCM450 expansion cabinet box and remove the components Verify that you have one BCM450 expansion cabinet Verify that you have one power supply cable Verify that you have one expansion cable shielded Ethernet cable Verify that you have four rubber feet Verify that you have the correct media bay modules MBMs Visually inspect the components for damage during shipping If you find damage or if you do not have all components contact your Nortel sales representative End Preinstallation checklists For preinstallation checklists see Installation Checklist and Quickstart Guide NN40160 300 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks BCM450 main unit and expansion cabinet installation To install a BCM450 system you must install a BCM450 main unit and an optional expansion cabinets with media bay modules MBM Prerequisites to main and expansion cabinet installation e A BCM450 system requires a main unit and can include an optional expansion cabinet BCM450 main unit and expansion cabinet installation tasks This work flow shows you the sequence of tasks you perform to install a main unit and expansion cabinet To link to any tasks go to BCM450 main unit and expansion cabinet installation navigation page 22 Nortel Business Communications M
42. ation Rear of MBM i or LOOTED mN Module Select Mode Country Select Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 108 GASM DIP switch configuration Table 2 Mode Select DIP switches switches 1 3 for the GASM Switch Description Setting Switch 1 Determines the firmware OFF Standard mode firmware download capability downloading not supported ON Enhanced mode firmware downloading supported Switch 2 Determines when the firmware is OFF if you want the GASM to downloaded from the BCM450 download the firmware when the for enhanced mode only firmware version in the BCM450 is different from the version in the GASM default ON if you want the GASM to download the firmware whenever a cold start occurs for the BCM450 Switch 3 Enables or disables echo OFF Enables echo cancellation cancellation default ON Disables echo cancellation Table 3 Country Select DIP switches switches 4 8 for the GASM Switch 4 Switch 5 Switch 6 Switch 7 Switch 8 North America OFF OFF OFF OFF OFF United OFF OFF OFF OFF ON Kingdom Australia OFF OFF OFF ON OFF Poland OFF OFF OFF ON ON Nortel Business Communications Manager 450 1 0 Copyright 2006 2009 Nortel Networks Installation System NN40160 301 01 04 Standard July 2009 Ports and c
43. ation about the wiring of the GATM4 or GATM8 see GATM wiring chart page 134 e For detailed information about the wiring of the G4x16 or G8x16 MBM see G4x16 and G8x16 wiring chart page 137 Procedure steps Step Action 1 If you use the GATM4 or GATMB plug the RJ 21 end of the connector cable into the RJ 21 connector on the front of the MBM OR If you have the G4x16 or G8x16 MBM plug the RJ 21 end of the connector cable into the lower RJ 21 connector on the front of the MBM 2 If you use a straight RJ 21 connector secure the RJ 21 connector to the MBM with the two supplied screws on the sides of the connector OR If you use a right angle RJ 21 connector secure the RJ 21 connector to the MBM with the supplied screw on the left side of the connector and with the supplied cable tie on the right side of the connector to fasten the 25 pair cable to the anchor on the MBM 3 Connect the other end of the connector cable to the telephone company demarcation blocks of the building End Connecting to DTM BRIM CTM and 4x16 MBMs Connect telephone lines to your BCM450 system through the DTM BRIM and 4x16 MBMs Prerequisites e If the network ISDN is a U loop you must connect the BRIM only to an NT1 provided by the service provider The NT1 must provide a Telecommunication Network Voltage TNV to Safety Extra Low Voltage SELV barrier e Do not attempt to plug digital equipment into the auxiliary AUX jacks on
44. ckboard is level 3 Mount the plywood backboard securely to the wall with appropriate screws Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks BCM450 main unit wall mount installation 33 End Installing the main unit using a wall mount bracket To install your BCM450 system on a wall you must install a wall mount bracket for the main unit and optional expansion cabinet Prerequisites e Obtain five 8 x 2 cm 8 x 0 75 in round head wood screws to attach the wall mount bracket to the backboard or wall e Obtain tools for the installation including a screwdriver for the wood screws a level and a pencil Procedure steps Step Action 1 Place the wall mount bracket on the backboard or wall and mark the location of the screw holes Use a bubble level to ensure that the wall mount bracket is level with the plywood backboard 2 Install four 10 x 2 5 cm 10 x 1 in round head screws in the backboard Leave approximately 0 5 cm 0 25 in of each screw exposed from the backboard or wall 3 Hang the wall mount bracket on the installed screws 4 Use a level to make sure the wall mount bracket is level 5 Remove the wall mount bracket from the backboard 6 Align the screw holes on one side of the BCM450 main unit with the wall mount bracket 7 Fasten the wall mount brackets securely to the BCM450
45. d extensions connect to the BCM450 main unit through an RJ 21 telephony connector on an MBM installed in the expansion cabinet Prerequisites to lines and extensions connection DANGER Risk of injury from electric shock Connect the ports on station modules only to approved digital telephones and peripherals with the proper cables on a protected internal wiring system DANGER Risk of injury from electric shock Electrical shock hazards from the telecommunications network and AC mains can occur with this equipment To minimize risk to service personnel and users you must connect the BCM450 system to an outlet with a third wire ground CAUTION Use only qualified persons to service the system Service personnel with appropriate training and experience must perform the installation and service of this unit Ensure service personnel are aware of the hazards of working with telephony equipment and wiring They must have experience in techniques that minimize any danger of shock or equipment damage e You must connect the power cords to a grounded outlet before you connect the telephony and data networking cables e Do not connect Digital Station ports DSM16 DSM32 and Analog Station ports GASMB8 to an exposed plant This includes Digital Station ports that reside on the combination MBMs G4x16 and G8x16 Use only proprietary Nortel Digital Station Sets to connect to digital ports and Nortel Busines
46. e 120 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 120 LED indicators reference Figure 24 DTM LEDs orm e Oa GOG o o Power LED Status LED In service LED Loopback test LED Receive LEDs Transmit LEDs For information about the possible DTM LED states see Table 10 DTM LEDs page 120 Table 10 DTM LEDs 1 of 2 Power Status Description Power See Media bay module LEDs page 118 for details Status See Media bay module LEDs page 118 for details In service Flashing The T1 ETSI or PRI trunks are out of service because a loopback test is running or the DTM is initializing Loopback test On A continuity loopback test is running Receive alarm On A problem with the received digital transmission This half duplex link does not work Receive error On A small error as a result of degraded digital transmission Possible causes are an ohmic connection water ingress or too long a loop Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks LED indicators reference 121 Table 10 DTM LEDs 2 of 2 Power Status Description Transmit alarm On The DTM cannot transmit The DTM sends an alarm indication signal AIS to the terminating switch This half duplex
47. e 86 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 86 Analog terminal adapter installation Figure 16 Analog terminal adapter installation procedures Connecting the ATAZ Mounting the ATA to a wall Testing insertion loss measurement Analog terminal adapter installation procedures navigation e Connecting the ATA2 page 86 e Mounting the ATA2 to a wall page 87 e Testing insertion loss measurement from the CO to the analog device page 88 e Testing insertion loss measurement from the analog device to the CO page 88 e Configuring the ATA2 page 89 Connecting the ATA2 After you have set up the correct environment connect the BCM system and the analog device to the ATA2 and then connect the power Prerequisites e An available station port on the BCM450 system is required Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Analog terminal adapter installation 87 Procedure steps Step Action 1 Connect one end of a line cord to the ATA2 terminal jack 2 Connect the other of the line cord to your telephone modem or fax machine Connect one end of a line cord to the ATA2 line jack Connect the other end of the line cord to an available digital station port For a 120 V or 230 V s
48. e external line isolation units LIU Auxiliary equipment connection procedures This task flow shows you the sequence of procedures you perform to install auxiliary equipment to the BCM 450 main unit To link to any procedure go to Auxiliary equipment connection navigation Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 70 Auxiliary equipment connection Figure 13 Auxiliary equipment connection procedures Fauxiliary ringer Connecting an auxiliary ringer Extemal paging Connecting an extemal paging system Extemal music source Connecting an extemal music source Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Auxiliary equipment connection 71 Auxiliary equipment connection navigation e Connecting an auxiliary ringer page 71 e Connecting an external paging system page 72 e Connecting the music source using the music source jack page 72 Connecting an auxiliary ringer An auxiliary ringer is a customer supplied piece of hardware that provides external ringing capability to telephones on the BCM450 system Prerequisites e You must not connect auxiliary ringer to unprotected plant wiring The ringer must not draw more than 50 mA from a 40 V DC source Procedure steps Ste
49. e one main unit In addition to a main unit the BCM450 system can include a BCM450 expansion cabinet An expansion cabinet connects to the main unit and provides additional functionality through one or more installed media bay modules MBM You can connect your BCM450 system directly to a power source or through an uninterruptible power supply UPS For a visual representation of a BCM450 system the following figure Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 14 Installation architecture Figure 1 BCM450 system architecture Expansion cabinet Main unit DHCP and IP addressing Each main unit includes a dynamic host configuration protocol DHCP server This DHCP server supplies Nortel IP Phones and client computers with IP addresses and connection information You can configure the DHCP server using Element Manager When the DHCP client is enabled the main unit receives IP configuration from a DHCP server External DHCP server not available If no external DHCP server is available the main unit uses the following default IP configuration IP address 192 168 2 2 Subnet mask 255 255 254 0 Gateway 192 168 1 1 The DHCP server on the main unit supplies IP configuration information for all IP devices PCs and IP Phones The DHCP server also supplies specific connection information to the IP Phones
50. ection describes how to reset the BCM450 system using the reset switch When the BCM450 is in this condition you can make further modifications After you reboot the BCM450 PC and SSH users will have access to Maintenance CLI See the following figure for the location of the reset switch Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 102 Troubleshooting Figure 18 Reset switch location Reset switch If the reset button is pressed for less then 5 seconds the BCM will begin the reboot process The reboot is completed in less then 30 seconds If you hold the BCM450 Reset Button for 5 seconds or more the BCM450 will immediately reboot Data loss may occur This should only be utilized when the BCM450 is not responding to normal reboot operations or is entirely non responsive If the BCM450 system has been shut down from the CLI the BCM450 Reset Button must be held for 5 seconds to initiate the reboot process After the restart is completed the BCM450 will wait up to 10 seconds for you to log onto the BCM Maintenance CLI If you do not log onto the Maintenance CLI after 10 seconds the BCM boots automatically to the Main OS Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Preinstallation reference Before yo
51. en a L Li a a a a E E eee a a kn Pa F a TTT EL On ig Top of MBM DIP switches Rear of MBM t Foi Rear view of MBM 2 Configure all DIP switches to on End Configuring MBMs for main unit installation Before installing an MBM in the expansion cabinet configure it through Element Manager and set the DIP switches Prerequisites e Before configuring an MBM install it in the main unit Procedure steps Step Action 1 In Element Manager navigate to Configuration gt Resources gt Telephony Resources Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks MBM installation 51 Choose the MBM bay i e Main 1 that you want to configure Under Configured Device select the type of MBM you want to install Press Configure a fF N Enter the Start DN Public received digits OLI Private received digits OLI and Start Line depending on the type of MBM Select or leave clear the Assign target lines check box Repeat for each media bay module you want to install End Configuring MBMs for expansion cabinet installation Before installing an MBM in the expansion cabinet configure it through Element Manager and set the DIP switches Procedure steps Step Action 1 In Element Manager navigate to Conf
52. eps 73 69 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Contents 5 LAN connection 75 Connecting the main unit to the LAN 76 Connecting IP devices to the LAN 76 BCM450 telephone and peripheral installation 79 Telephone installation 81 Installing an emergency telephone 81 IP phone installation 82 Mobility system installation 82 T7406e cordless telephone installation 82 Capacity expansion card installation 83 Installing the CEC 83 83 Analog terminal adapter installation 85 Connecting the ATA2 86 Prerequisites 86 Procedure steps 87 Mounting the ATA2 to a wall 87 Testing insertion loss measurement from the CO to the analog device 88 Prerequisites 88 Procedure steps 88 Testing insertion loss measurement from the analog device to the CO 88 Prerequisites 88 Procedure steps 88 Configuring the ATA2 89 Element Manager installation 91 Element Manager installation procedures navigation 91 Downloading and installing Element Manager 92 Procedure steps 92 Connecting to the BCM450 through Element Manager 93 Configuring user access 93 Prerequisites 93 Procedure steps 94 BCM450 common procedures 95 Rebooting the BCM450 95 BCM450 shut down 96 Installation troubleshooting 96 Checking LED status 96 Checking DIP switches 96 Troubleshooting 97 Troubleshooting navigation 97 Nortel Busines
53. es to BCM450 main unit wall mount installation e wall mount bracket kit NTAB3422 e four 10 x 2 5cm 10 x 1in round head wood screws e plywood backboard 2 cm 3 4 in thick BCM450 main unit wall mount installation procedures This task flow shows you the sequence of procedures you perform to install a main unit on the wall To link to any procedure go to BCM450 main unit wall mount installation navigation page 32 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 32 BCM450 main unit wall mount installation Figure 7 Installing the wall mount bracket hunting the bem460 on the brtacket BCM450 main unit wall mount installation procedures BCM450 main unit wall mount installation navigation e Mounting the backboard page 32 e Installing the main unit using a wall mount bracket page 33 Mounting the backboard Mount a plywood backboard on a wall to simplify installation of your BCM450 main unit and optional expansion cabinet Prerequisites e Ensure plywood backboard is 2 cm 3 4 in thick e Obtain a pencil ruler screwdriver and a level e Obtain appropriate screws and optional wall anchors to attach the backboard to the wall Procedure steps Step Action 1 Use a pencil to mark the desired location of the plywood backboard on the wall 2 Use a ruler and a level to make sure that the plywood ba
54. ew Network Element and then select Business Communications Manager 3 Enter the BCM system IP address the user name and password see the following for defaults IP address 192 168 2 2 Username nnadmin Password PlsChgMe 4 Click OK You are now connected to the BCM system For more information about using BCM Element Manager see the online Help within BCM Element Manager End Configuring user access After you have installed Element Manager and connected to the BCM450 system you can create and configure user accounts for Element Manager Prerequisites e Element Manager must be installed on your PC Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 94 Element Manager installation e You must be logged on to Element Manager and have administrator access Procedure steps Step Action 1 From the Configuration tab click the Administrator Access folder to expand it Select Accounts and Privileges from the Administrator Access folder Select the View by Accounts tab Click Add to add a user account The Add Account dialog box appears Configure the Add Account attributes Click Ok 7 Repeat steps step 4 to step 6 to create more user accounts O a BB W DN Table 1 Add account attributes Attribute Description Description Enter a description for this account User ID Enter a
55. f the power cables from the power supply to the electrical outlet including power bar must not exceed 2 m 6 5 ft The supplied power must be a dedicated 110 V to 120 V AC nominal or 220 V to 240 V AC nominal 50 to 60 Hz 15 A minimum service with a third wire safety ground The third wire safety ground provides shock protection and prevents electromagnetic interference If you use a power bar the power bar must be approved by an appropriate National Test Body with a third wire ground Nortel recommends that you do not use an extension cord between the power supply and the power bar or between the power bar and the electrical outlet DANGER Risk of electric shock The safety of this product requires connection to an outlet with a third wire ground Use only with the supplied BCM450 power cord and a three wire power outlet CAUTION Check ground connection Ensure that the electrical ground connections of the power utility telephone lines and internal metal water pipe system if present are connected If these ground connections are not connected contact the appropriate electrical inspection authority Do not try to make the connections yourself Site telephony wiring requirements The following sections describe the requirements for wiring digital telephony devices digital loop and analog telephony devices analog loop to the BCM450 system Digital loop You must meet the following parameters for a
56. function properly if you connect the BCM expansion cabinet using a cable of a different length Procedure steps Step Action 1 Plug one end of the supplied DS256 cable in the DS256 connector on the expansion cabinet Expansion cabinet Main unit 2 Plug the other end of the cable into the DS256 connector on the faceplate of the MSC in the BCM450 main unit End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 42 BCM450 expansion cabinet installation Copyright 2006 2009 Nortel Networks MBM installation To add a media bay module MBM to your system configure the DIP switches for your MBM and install it into the main unit or expansion cabinet Each MBM you add increases the number of public switched telephone network PSTN trunks or extensions that you can connect to the BCM450 system For more information about the types and functionality of MBMs see Business Communication Manager 450 1 0 Installation Devices NN40160 302 Prerequisites to MBM installation e The MBMs are safety approved for installation into the BCM450 system The installer and user must ensure that hardware installation does not compromise existing safety approvals or local electrical code regulations for telecommunications equipment and wiring installation MBM installation procedures This task flow shows yo
57. hen when terminated with terminated with Hz when terminated with terminated with 600 ohms 600 ohms terminated 600 ohms 600 ohms with 600 ohms Insertion loss ATA2 to ATA2 to BCM50 ATA2 to BCM50 ATA2 to BCM50 ATA2 to on an internal BCM50 loss 3 0 loss 3 0 dB 0 5 loss 3 0 dB 0 5 loss 3 0 dB 0 5 BCM50 loss call dB 0 5 dB dB dB dB 3 0 dB 0 5 dB Insertion loss ATA2 to ASM to BCM50 ASM to BCM50 ASM to BCM50 ASM to on an external BCM50 loss 2 2 loss 3 0 dB 1 0 loss 3 0 dB 1 0 loss 3 0 dB 1 0 BCM50loss call dB 1 0 dB dB BCM50 to dB BCM50 to dB BCM50 to 3 0 dB 1 0 BCM50 to ASM loss 0 5 dB ASM loss 0 5 dB ASM loss 0 5 dB dB BCM50 ATA2 loss 0 5 1 0 dB 1 0 dB 1 0 dB to ASM loss dB 1 0 dB 0 5 dB 1 0 dB Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Analog device specifications 113 Table 5 ATA2 ASM8 ASM8 GASM and GASI analog device specifications 3 of 3 Specification ATA2 ASM8 ASM8 GASM GASI MWI type see Stutter tone Stutter tone Stutter tone Stutter tone Stutter Note Voltage MWI Reverse polarity Tone CO 120 V Voltage MWI Reverse CO 120 V polarity Voltage MWI PBX 90 V Disconnect N A N A OSI EIA TIA 464 OSI EIA TIA 464 N A supervision section section types 4 5 10 2 4 4 5 10 2 4 4 5 10 2 5 1 4 5 10 2 5 1
58. iguration gt Resources gt Telephony Resources Select Expansion 1 from the table A menu appears Choose the MBM bay i e Expansion 1 1 that you want to configure Under Configured Device select the type of MBM you want to install Press Configure Enter the Start DN Public received digits OLI Private received digits OLI and Start Line depending on the type of MBM O a BB ND J Select or leave clear the Assign target lines check box Locate the DIP switches at the rear or underside of the MBM Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 52 MBM installation x Underside of MBM aneng we a k C1 654321 O 5 keanaan F k Da i a t Stapana On 123456 Top of MBM DIP switches ee Rear of MBM Rear view of MBM 9 Set the switches to correspond with the settings shown in the Configure window 10 Repeat for each media bay module you want to install End Installing an MBM in the main unit or an expansion cabinet After configuring the DIP switches on an MBM you can install it in the BCM450 main unit or expansion cabinet Prerequisites Ensure that the DIP switches are configured correctly For more information about configuring the DIP switches see Configuring the G4x16 or G8x16 DIP switches page 45 Configuring the GASM DIP sw
59. itch to one of the available LAN ports Repeat step 1 and step 2 for each IP device you want to connect to the LAN End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 78 LAN connection Copyright 2006 2009 Nortel Networks BCM450 telephone and peripheral installation This chapter describes how to install and configure telephones and other peripheral devices for BCM450 BCM450 telephone and peripheral installation navigation e Telephone installation page 81 e Capacity expansion card installation page 83 e Analog terminal adapter installation page 85 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 80 BCM450 telephone and peripheral installation Copyright 2006 2009 Nortel Networks Telephone installation This chapter describes how to connect telephones to your BCM450 system Prerequisites to telephone installation e To operate the BCM450 expansion cabinet at the optimal internal temperature ensure the top sides and rear clear of obstructions and away from the exhaust of other equipment e Ensure no objects are on top of the expansion cabinet Telephone installation navigation e Installing an emergency telephone page 81 e P phone installation page 82 e Mobili
60. itches page 46 Configuring the GATM DIP switches page 46 To connect the fiber cables page 48 Fiber expansion module configuration page 47 or Configuring MBMs for expansion cabinet installation page 51 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks MBM installation 53 e MBMs are configured through Element Manager If installing an MBM in the main unit configure it after it is installed If installing the MBM in the expansion cabinet configure the MBM before installing it For more information on configuring MBMs for the expansion cabinet see Configuring MBMs for expansion cabinet installation page 51 Attention Due to power constraints a maximum of 2 GASM MBMs are supported in the main unit Up to 4 GASM MBMs can be installed on the expansion cabinet CAUTION Make sure the power supply to the expansion cabinet is disconnected before inserting or removing an MBM CAUTION Risk of equipment damage To prevent damage from electrostatic discharge always wear an antistatic wrist strap connected to an ESDS grounding jack whenever you handle printed circuits Procedure steps Step Action Select an open media bay 2 Hold the MBM with the face of the MBM toward you 3 Push the MBM completely into the MBM bay until you hear a click End R2MFC MBM installation
61. k of the base function tray so that the CEC protrudes slightly from the front faceplate of the base function tray 6 Align the connectors on the card and on the main board of the base function tray and push down Ensure that the card is connected securely to the main board Use the four supplied screws to fasten the card to the standoffs Reinstall the base function tray and power on the BCM450 system End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Analog terminal adapter installation This chapter describes how to install an analog terminal adapter ATA or ATA2 for the BCM450 You can use an ATA to connect a standard analog voice device or data communication device to the BCM system through a digital station module Examples of analog voice devices include analog telephones and answering machines Examples of data communication devices include modems and fax machines Prerequisites to ATA2 installation e In North America the ATA2 must be powered from a UL and CSA approved Class 2 power source e In Europe the ATA2 must be powered from a Class II power source that is CE marked Analog terminal adapter installation procedures This task flow shows you the sequence of procedures you perform to install an ATA2 To link to any procedures go to Figure 16 Analog terminal adapter installation procedures pag
62. lect DIP switches switches 1 to 3 on the right side at the rear of the module according to the requirements for your BCM450 system 4 Configure the Country Select DIP switches switches 4 to 8 on the right side at the rear of the module according to the regional requirements for your BCM450 system End Configuring the GATM DIP switches Before you install the GATM into the main unit configure the DIP switches to the default factory positions Make the required modifications by using the software Procedure steps Step Action Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks MBM installation 47 1 Locate the Module Select and Mode Country Select DIP switches at the rear of the GATM Rear of MBM ort LAAT Module Select Mode Country Select 2 Configure the Module Select DIP switches on the left side at the rear of the module to on up 3 Configure the Mode Country Select DIP switches on the right side at the rear of the module to off down The GATM automatically downloads the country profiles End Fiber expansion module configuration The Fiber Expansion media bay module FEM connects a maximum of six Norstar expansion modules Norstar TM Norstar SM and Norstar ASM to the Business Communications Manager system These connections provide a quick way to upgr
63. lified persons to service the system Service personnel with appropriate training and experience must perform the installation and service of this unit Ensure service personnel are aware of the hazards of working with telephony equipment and wiring They must have experience in techniques that minimize any danger of shock or equipment damage Nortel Business Communications Manager 450 1 0 Copyright 2006 2009 Nortel Networks Installation System NN40160 301 01 04 Standard July 2009 58 Power connection CAUTION Risk of equipment damage Service personnel must be alert to the possibility of high leakage currents becoming available on metal system surfaces during power line fault events near network lines These leakage currents normally safely flow to protective earth ground through the power cord System shutdown You must disconnect the media bay module cables from the system before you disconnect the power cord from a grounded outlet System startup You must reconnect the power cords to a grounded outlet before you reconnect the cables to the media bay modules Prerequisites to power connection e Install the BCM450 main unit and optional expansion cabinet For more information see BCM450 main unit installation page 25 and BCM450 expansion cabinet installation page 37 Power connection procedures This task flow shows you the sequence of procedures you perform to connect power to your BC
64. link does not work Transmit error On The DTM is sending a remote alarm indication RAI carrier failure alarm CFA to the terminating switch If the transmit alarm is not on this error indicates a far end or cable problem BRIM LEDs The BRIM has one additional LED beside each RJ 48C jack These LEDs are on if the ISDN line is active For information about the location of the LEDs on a BRIM see Figure 25 BRIM LEDs page 121 Figure 25 BRIM LEDs ISDN BRI S T Interface Loop 1 Loop 2 Loop 3 Loop 4 A Power Sthtus Power LED Status LED For more information about the power and status LED functions see Media bay module LEDs page 118 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 122 LED indicators reference Copyright 2006 2009 Nortel Networks System information and tools Use the following information to prepare for your BCM450 hardware installation Navigation e Media bay modules page 123 e Additional hardware page 125 e Tools page 125 e System information page 126 Media bay modules Trunk media bay modules connect telecommunications lines to the BCM450 system For a list of the types of trunk media bay modules that are available for the BCM450 system see Table 11 Trunk MBMs page 123 Table 11 Trunk MBMs Module type Function Notes
65. ment Manager access is also supported through a Citrix server Procedure steps Step Action 1 Open a Web browser and enter the BCM system IP address The Enter Network Password dialog box appears 2 Enter the user name and password see the following for defaults Username nnadmin Password PlsChgMe 3 Click OK The Welcome to BCM Web page appears 4 On the Welcome to BCM Web page click Administrator Applications The Administrator Applications page appears 5 On the Administrator Applications page click BCM Element Manager The BCM Element Manager pane appears 6 Click Download Element Manager on the right side of the screen and follow the instructions to download Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Element Manager installation 93 7 After BCM Element Manager finishes downloading double click the application and follow the installation instructions End Connecting to the BCM450 through Element Manager After you install Element Manager on your PC use it to connect to the BCM450 system Prerequisites e Element Manager must be installed on your PC e Your BCM must be powered on and connected to the network or connected directly to your PC through the OAM port or serial port Procedure steps Step Action 1 Open BCM Element Manager 2 From the Network menu select N
66. module configuration page 47 Procedure steps Step Action 1 Check the Power and Status LEDs on the MBM Both LEDs must be solid green If either LED is not solid green a problem exists with the MBM Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Troubleshooting 99 2 Go to an extension on the MBM if it is a station MBM OR Go to an extension that has access to one of the lines on the MBM if it is a trunk MBM Select the line or line pool to which the line belongs Check for a dial tone Use this extension to make a call to another extension on the system if it is a station MBM OR Make a call using the line or line pool if it is a trunk MBM 5 Use this extension to make a call to an external telephone number if you are testing a station MBM End Determining why an MBM does not appear in Element Manager Use the following procedure if an installed MBM does not appear in Element Manager Procedure steps Step Action 1 Check that the correct feature is included in your installed keycode Check that both the Power and Status LEDs on the MBM are solid green If the Power LED is off and the MBM is installed in the expansion cabinet check that the power supply cable is properly seated in the expansion cabinet and the power supply is connected to a working power outlet 4 Ensure that
67. ms also arise if you set the DIP switches on your installed MBMs incorrectly For information about setting DIP switches see MBM installation page 43 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Troubleshooting 97 Troubleshooting This chapter describes how to troubleshoot the BCM450 system Troubleshooting navigation Testing the main unit page 97 Troubleshooting the main unit page 98 Determining why an MBM does not appear in Element Manager page 99 Troubleshooting the FEM page 100 Troubleshooting the ATA2 page 100 Troubleshooting dial tone problems with the ATA2 page 100 Checking ATA2 wiring page 101 BCM450 system reset page 101 Testing the main unit Use the following procedure to test the main unit Procedure steps Step Action N OO Oo Go to an extension that is connected to the RJ 21 telephony connector on the main unit Check for a dial tone Use this extension to make a call to another extension on the system If this system is connected to an expansion cabinet with a media bay module MBM that supports extensions repeat steps 2 and 3 for an extension connected to the expansion cabinet Go to an extension that has access to one of the lines on the main unit Select the line or line pool to which the line belongs Check for a dial tone Make a call using the
68. n unit or expansion cabinet on a wall To mount the unit on a wall you need the following items e A wall mount bracket kit NTAB3422 e Four 10 x 2 5 cm 10 x 1 in round head wood screws e A plywood backboard 2 cm 3 4 in thick To mount the expansion cabinet you need the following items e A wall mount bracket supplied with unit e Two 10 x 2 5 cm 10 x 1 in round head screws e A plywood backboard 2 cm 3 4 in thick Desktop mount installation You can install a BCM450 main unit or expansion cabinet on a desktop or a shelf Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 16 Installation architecture Miscellaneous features The following sections describe some additional features of the BCM450 system External music source You can connect an external music source for music on hold For more information about installing an external music source see Connecting the music source using the music source jack page 72 Analog telephones and devices You can use an analog terminal adapter ATA2 to install analog telephones and data devices such as fax machines on your BCM450 system For more information about installing an ATA2 see Analog terminal adapter installation page 85 Element Manager You can use Element Manager to configure and monitor your BCM450 system For more information about installing Elemen
69. nit page 41 Mounting the expansion cabinet in an equipment rack You can install your BCM450 expansion cabinet in a standard 19 inch equipment rack Prerequisites e Use only the screws supplied with the BCM450 expansion cabinet Other screws can damage the BCM450 expansion cabinet Procedure steps Step Action 1 Place the expansion cabinet on a flat clean surface Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks BCM450 expansion cabinet installation 39 Align the screw holes between the expansion cabinet and the right rack mount bracket Fasten the bracket to the expansion cabinet by using the four screws Align the screw holes between the expansion cabinet and the left rack mount bracket Fasten the bracket to the expansion cabinet by using four screws Determine the location in the rack where you want to install the expansion cabinet Position the expansion cabinet in the rack Have an assistant hold the expansion cabinet Align the holes in the rack mount bracket with the holes in the equipment rack rails Fasten the rack mount brackets to the rack using the four supplied rack screws End Installing the expansion cabinet on a wall To mount the BCM450 expansion cabinet on a wall you must install the expansion cabinet on the previously installed wall mount bracket You cannot install
70. o based mobility systems have documentation that describes the hardware and installation and activation of the handsets The BCM main unit can support a maximum of two digital mobility controllers DMC which are the call processing units between the BCM main unit and the digital mobility base stations and handsets The DMCs have a one to one connection with digital ports on the BCM main unit For installation and configuration details see the Digital Mobility Installation and Configuration Guide NO000623 T7406e cordless telephone installation The T7406e cordless system consists of a base station that connects up to three digital station ports on the BCM450 system that provide a radio interface for three cordless handsets The cordless handsets register to the base station which transfers the call over the telephone lines connected to the system The handsets are configured to emulate the T7316 M7310 telephone features This system is most suited for small to medium sized office environments that are set up in an open fashion For installation and configuration details refer to the T7406E Cordless Handset Installation and Configuration Guide NN401 10 301 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Capacity expansion card installation This chapter describes how to install the optional capacity expansion card CEC
71. o system Solid yellow Off Power on self test POST Lasts for 9 seconds Solid yellow Solid yellow System initializing lasts 14 seconds Solid green Solid yellow Kernel initialization lasts 8 seconds or Safe OS Solid green Blink green Services initializing lasts 1 minute Solid green Solid green Normal operation Solid green Solid red Services initialization failed LED states seen during Safe Mode start up sequence Solid red Solid green System running with factory default settings enabled Solid red Solid red System running in Software Reset mode Nortel Business Communications Manager 450 1 0 Copyright 2006 2009 Nortel Networks Installation System NN40160 301 01 04 Standard July 2009 LED indicators reference 117 Power Status Description Solid red Blink yellow System running in Configuration Reset mode LED states seen during shut down sequence or failure Solid green Blink yellow Graceful shutdown in progress Off Solid yellow Graceful shutdown completed Solid red Blink yellow Overheat detected Thermal shutdown completed Solid red Solid red Power spike or Rail power fluctuation detected Blink red Solid red Rail power fluctuation Power Monitor Shutdown completed Solid yellow Solid red Power spike shutdown completed temperature and Rail power ok Off Off No power system is shut down power cable is disconnected LED states seen during initial system install or
72. onnectors reference The BCM450 main unit and BCM450 expansion cabinet have ports and connectors that provide functionality to your BCM450 system Navigation e Main unit ports and connectors page 109 Main unit ports and connectors This section describes the ports and connectors for the different BCM450 main units Figure 18 illustrates the location of ports and connectors on the BCM450 Figure 20 BCM450 main unit ports and connectors OAM LAN LAN Musc Auxiliary Page DS256 port 0 port 1 pog 2 source ringer relay output Table 4 describes the ports and connectors on the BCM450 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 110 Ports and connectors reference Table 4 BCM450 main unit ports connectors and descriptions Port connector Description OAM port port 0 An RJ 45 jack used to connect a computer running administration software such as Element Manager to the main unit LAN ports port 1 2 RJ 45 jacks used to connect the customer LAN to the main unit COM port serial port Used to connect to the BCM450 system using a serial cable USB port Two USB 2 0 ports used to connect a USB storage device in the bottom port only or the data interface for an uninterruptible power supply UPS to the main unit The main unit uses the data interface for the UPS to monitor
73. ons Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Contents 7 Wiring charts reference 131 DTM wiring chart 131 BRIM wiring chart 132 ADID wiring chart 133 GATM wiring chart 134 4x16 wiring chart 137 G4x16 and G8x16 wiring chart 137 DSM16 and DSM32 wiring chart 138 ASM8 ASM8 and GASM wiring chart 139 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Contents Copyright 2006 2009 Nortel Networks New in this release The following sections detail what s new in Nortel Business Communications Manager 450 Installation System NN40160 301 for Release 1 0 Features Other Changes Features page 9 Other Changes page 9 Simplified DIP switch settings MBMs are configured through Element Manager For more information see MBM installation page 43 Support for Norstar Legacy modules with the Fibre Expansion Module MBM For more information see Fiber expansion module configuration page 47 Upgradable capacity with the new Capacity Expansion Card CEC For more information see Installing the CEC page 83 Revision History July 2009 Standard 01 04 This document is up issued to update technical information in the section Connecting an external paging system Nortel Business Communications Manager
74. p Action 1 Install the auxiliary ringer using the installation instructions supplied with the ringer hardware 2 Connect the ringer generator to the auxiliary ringer connection on the Base Function Tray End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 72 Auxiliary equipment connection Connecting an external paging system You can connect a customer supplied external paging system to provide paging over external loudspeakers Prerequisites e You must connect the paging connections to unprotected telephony plant wiring e External paging does not support talk back paging equipment unless you use an external line port The BCM450 system provides paging over the telephone speakers when no external paging equipment is available e A Standard 1 8 Stereo mini jack is needed for the paging port on the Base Function Tray e Ensure the paging system follows these guidelines The paging output from the main unit is 100 mV rms across an input impedance of 600 Q The output level is 0 dBm0 with reference to 600 ohms for a PCM encoded signal at 0 dBm No DC voltage exists across the page output terminals When you use the page signal output to connect an external paging amplifier you also use the page relay output that contains a floating relay contact pair The system uses this output to control the extern
75. ple Hewlett Packard 4935A Transmission Test Set Procedure steps Step Action 1 Establish a connection to the 1 mW 1 kHz CO service line with an analog telephone connected to the ATA2 Replace the analog telephone with the test set Use RECEIVE 600 OHM HOLD mode on the test set Ensure that the analog port terminates correctly in 600 ohms a fF N Ensure that the test set connects in parallel to the service line before you remove the analog telephone or the line drops e gt Remove the single line telephone Measure the 1 kHz tone at the far end of the analog port where the analog loop ends and the analog device connects End Testing insertion loss measurement from the analog device to the CO The maximum loss for ATA2 to Central Office CO configuration must not exceed 10 dB and must be greater than 10 dB Measure the total insertion loss between the CO and analog device by using standard dial up test lines with a transmission test set Prerequisites e You will need a transmission test set for example Hewlett Packard 4935A Transmission Test Set Procedure steps Step Action Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Analog terminal adapter installation 89 1 Establish a connection to a silent termination on the CO service line with an analog telephone connected
76. s Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 6 Contents Testing the main unit 97 Use the following procedure to test the main unit 97 Procedure steps 97 Troubleshooting the main unit 98 If a test fails use the following procedure to troubleshoot the main unit 98 Procedure steps 98 Testing an MBM 98 Procedure steps 98 Determining why an MBM does not appear in Element Manager 99 Procedure steps 99 Troubleshooting the FEM 100 Procedure steps 100 Troubleshooting the ATA2 100 Troubleshooting dial tone problems with the ATA2 100 Checking ATA2 wiring 101 BCM450 system reset 101 Preinstallation reference 103 Environmental requirements 103 Electrical requirements 103 Site telephony wiring requirements 104 GASM DIP switch configuration 107 GASM DIP switch configuration 107 Ports and connectors reference 109 Main unit ports and connectors 109 Analog device specifications 111 ATA2 ASM8 ASM8 GASM and GASI analog device specifications 111 LED indicators reference 115 System status monitor LEDs 115 Hard disk drive LEDs 117 LAN portLEDs 117 Media bay module LEDs 118 DTM LEDs 119 BRIM LEDs 121 System information and tools 123 Media bay modules 123 Additional hardware 125 Tools 125 System information 126 Default values reference 129 Default user names and passwords 129 Nortel Business Communicati
77. s Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 64 Lines and extensions connection agency approved Analog devices for connection to the Analog Station ports e Do not connect telephones to wiring that extends to the outside of the building Lines and extensions connection procedures This task flow shows you the sequence of procedures you perform to connect the lines and extensions To link to any procedure go to Lines and extensions connection navigation Figure 12 Lines and extensions connection procedures Analog lines Connecting to a OSMI6 32 ASME or 4 G4 G8x16 MBM Connecting to a OTM BRIM or 4x16 MBM GATM or G4 G8x16 Connecting to a GATE G G8x16 MBM Lines and extensions connection navigation e Connecting to GATM4 GATM8 and G4x16 8x16 MBMs page 65 e Connecting to DTM BRIM CTM and 4x16 MBMs page 65 e Connecting to DSM16 DSM32 ASM8 MBMs page 66 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Lines and extensions connection 65 Connecting to GATM4 GATM8 and G4x16 8x16 MBMs Analog telephone lines connect to your BCM450 system through the GATM4 GATM8 and G4x16 G8x16 CTM MBMs Prerequisites e Obtain a 25 pair connector cable with an RJ 21 connector on one end e For detailed inform
78. sion cabinet You can install the expansion cabinet in a standard 19 inch equipment rack on a wall or on a desktop Add an expansion cabinet to increase the capacity of your BCM450 system Prerequisites to expansion cabinet installation e To operate the BCM450 expansion cabinet at the optimal internal temperature ensure the top sides and rear clear of obstructions and away from the exhaust of other equipment e Ensure no objects are on top of the expansion cabinet BCM450 expansion cabinet installation procedures This task flow shows you the sequence of procedures you perform to install an expansion cabinet To link to any procedures go to BCM450 expansion cabinet installation navigation page 38 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 38 BCM450 expansion cabinet installation Equipment rack Expansion cabinet rack mount installation Figure 8 BCM450 expansion cabinet installation procedures Expansion cabinet wall mount installation Expansion cabinet desktop installation Connecting the expansion cabinet to the main unit BCM450 expansion cabinet installation navigation e Mounting the expansion cabinet in an equipment rack page 38 e Installing the expansion cabinet on a wall page 39 e Installing the expansion cabinet on a desktop page 40 e Connecting the expansion cabinet to the main u
79. staging Blink Yellow Blink Yellow Start up Profile executing Solid Green Solid Green Start Up Profile successfully applied Blink Yellow Blink Red Start Up Profile Failure Hard disk drive LEDs The following table describes the possible LED states for the hard disk drive LED Table 7 HDD LED states LED Description Off No HDD detected Green Normal operation Red HDD fault Orange Flashing Activity Orange LAN port LEDs Each LAN port on the main unit has two LEDs These LEDs indicate the status of the connection for that LAN port For the location of the LEDs on the main units and expansion cabinet see Figure 22 LAN port LEDs page 118 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 118 LED indicators reference Figure 22 LAN port LEDs LAN port LEDs For information about the possible LED states for the LAN ports LEDs see Table 8 LAN port LEDs page 118 Table 8 LAN port LEDs LED Status Description Yellow On The LAN port is operating at 10 Mb s Green On The LAN port is operating at 100 Mb s Both LEDs Off No connection Any LED Flashing The LAN port is sending or receiving network data The frequency of the flashes increases with increased traffic Media bay module LEDs The two media bay module MBM LEDs on an expansion cabinet show the power and
80. stem BCM 450 installation preparation procedures This task flow shows you the sequence of procedures you perform to prepare to install your BCM450 system To link to any procedure go to BCM450 installation preparation navigation page 18 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 18 BCM450 installation preparation Figure 2 BCM450 installation preparation procedures Verifying the site requirements Verifying the main unit components Verifying the expansion cabinet components BCM450 installation preparation navigation e Verifying the site requirements page 18 e Verifying the main unit components page 19 e Verifying the expansion cabinet components page 19 e Preinstallation checklists page 20 Verifying the site requirements Before you install the BCM450 system verify that your site meets the installation requirements Prerequisites e For details about environmental electrical and telephony wiring requirements see Preinstallation reference page 103 Procedure steps Step Action 1 Determine the location for the main unit and optional expansion cabinet telephones and other equipment Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks BCM450 installation preparation 19
81. straight RJ 21 connector secure the RJ 21 connector to the MBM with the two supplied screws on the sides of the connector Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Lines and extensions connection 67 OR If you use a right angle RJ 21 connector secure the RJ 21 connector to the MBM with the supplied screw on the left side of the connector and with the supplied cable tie on the right side of the connector to fasten the 25 pair cable to the anchor on the MBM Connect the other end of the cable to the local connecting blocks If you connect extensions to a DSM32 repeat step 1 to step 2 for the second RJ 21 connector End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Copyright 2006 2009 Nortel Networks Auxiliary equipment connection The main unit includes connections for an auxiliary ringer an external paging system and a music source Prerequisites to auxiliary equipment connection CAUTION SELV warning External equipment connected to the auxiliary ringer page relay page output and music on hold interfaces must use safety extra low voltage SELV All four auxiliary interfaces use SELV and the external equipment connected to these interfaces must use SELV or you must us
82. sufficient startup time 30 60 sec Plug an analog device into the phone port of the ATA2 and check for a dial tone End Troubleshooting dial tone problems with the ATA2 Use the following procedure if there is no dial tone on the ATA2 Step Action 1 If you hear no dial tone replace a single line telephone for the data communication device Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Troubleshooting 101 2 If you hear no dial tone at the ATA2 unit disconnect the line side of the ATA2 Connect a digital telephone to the ATA2 port Check that the connection from the ATA2 to the BCM450 hardware works correctly End Checking ATA2 wiring If the problem with the ATA2 persists use the following procedure to check the wiring Step Action 1 Use an analog phone to test the ATA2 2 Check the connection from the ATA2 to the terminal The resistance must be 200 ohms or less for data applications and 1300 ohms or less for voice applications Check the connection from the BCM450 hardware to the ATA2 Check that the connection from the ATA2 to the BCM450 hardware works correctly The wiring must be equivalent to 800 m of 0 5 mm wire 2600 ft of 24 AWG or less Do not use bridge taps and loading coils between the BCM450 hardware and ATA2 End BCM450 system reset This s
83. t ASM8 ASM8 and GASM wiring chart Analog telephony devices such as single line telephones modems and Fax machines connect to the Analog Station Module ASM through the RJ 21 connector on the front of the media bay module To view the connector see Figure 33 ASM8 ASM8 and GASM connector page 139 Figure 33 ASM8 ASM8 and GASM connector Can 26 50 RJ 21 pin out RJ 21 connector Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks s reference Copyright 2006 2009 Nortel Networks Nortel Business Communications Manager 450 1 0 Installation System Copyright 2006 2009 Nortel Networks Sourced in Canada the United States and the United Kingdom All Rights Reserved Publication NN40160 301 Document status Standard Document issue 01 04 Document date July 2009 Product release 1 0 Job function Installation Type Document Language type English NORTEL the globemark design and the NORTEL corporate logo are trademarks of Nortel Networks To provide feedback or report a problem with this document go to www nortel com documentfeedback NORTEL
84. t using the screws provided 8 Hang the expansion cabinet on the backboard screws Make sure the expansion cabinet is level Ensure the wood screw heads seat fully into the wall mount bracket slots 9 Tighten the wood screws against the wall mount bracket End Installing the expansion cabinet on a desktop If you cannot install your BCM450 expansion cabinet in an equipment rack or on a wall you can install your expansion cabinet on a desktop or shelf Prerequisites e Locate the four self adhesive rubber feet e Leave enough space around the expansion cabinet for ventilation and access to the cables Procedure steps Step Action 1 Remove the paper backing from the four enclosed self adhesive rubber feet 2 Attach the four self adhesive rubber feet to the bottom of the expansion cabinet 3 Position the expansion cabinet on a desktop or shelf End Connecting the expansion cabinet to the main unit Connect the expansion cabinet to the main unit to gain additional functionality provided by the MBMs Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks BCM450 expansion cabinet installation 41 Prerequisites e ADS256 cable NTAB3086 supplied Attention The timing in the BCM450 system is critical Use the correct length of cable as supplied with the expansion cabinet 5 m The system cannot
85. t Manager For information to install Element Manager see Element Manager installation page 91 Prerequisites e Element Manager must be installed on a PC connected to the BCM450 system either through the LAN soft modem ISDN or directly through the OAM port Step Action Check for a recent backup of the BCM450 system programming 2 If no recent backup is available use Element Manager to back up the system data For information about backing up the system data see Nortel Business Communication Manager 450 1 0 Administration and Security NN40160 601 3 From the Administration tab click the Utilities folder to expand it 4 From the Utilities folder select Reset 5 Click Reboot BCM450 System to reboot the system End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 96 BCM450 common procedures BCM450 shut down For information about shutting down an in service BCM450 system see Business Communications Manager 450 1 0 Maintenance NN40160 503 Installation troubleshooting This section describes how to troubleshoot a BCM450 installation Checking LED status You can use the status and power LEDs on the faceplate of the BCM450 base function tray to help troubleshoot hardware issues For more information about system LEDs see LED indicators reference page 115 Checking DIP switches Proble
86. t Manager on a PC see Element Manager installation page 91 Startup Profile An experienced administrator can use the Startup Profile tool with common BCM parameters You can use the Startup profile to quickly configure one or multiple systems Create the Startup Profile using the Startup Profile template a Microsoft Excel template Then use a USB storage device to transfer the Startup Profile data to the BCM main unit For more information about Startup Profile and templates see Nortel Business Communications Manager 450 1 0 Configuration System NN40160 503 Attention Voicemail parameters are not available through Startup Profile Line and data connector wiring For information about connecting telephone and data lines to media bay modules MBMs see Lines and extensions connection page 63 For information about connecting the BCM450 to a LAN see LAN connection page 75 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks BCM450 installation preparation Verify that your site meets all requirements and that you have the required main unit and expansion cabinet components before you install the BCM450 system Prerequisites to BCM450 installation preparation e The BCM450 expansion cabinet is an optional component The expansion module increases the number of media bay modules MBMs you can install in the sy
87. ting to the BChWH50 through Bement htanager Configuring user access Element Manager installation procedures navigation e Downloading and installing Element Manager page 92 e Connecting to the BCM450 through Element Manager page 93 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 92 Element Manager installation e Configuring user access page 93 Downloading and installing Element Manager After your computer connects to the BCM450 system either through an Ethernet crossover cable or through a LAN connection you can download BCM Element Manager from the Administrator Applications area of the BCM Web page Use BCM Element Manager to connect to and configure your BCM450 system BCM applications for BCM450 support the following Vista versions Microsoft Vista Business Microsoft Vista Ultimate and Microsoft Vista Enterprise Both 32 bit and 64 bit versions of Windows Vista are supported except for the limitations identified in Business Communications Manager 450 System Overview NN40160 103 Prerequisites e Element Manager is compatible with Windows 98SE Windows 2000 Windows XP and Windows Vista Windows 2000 server Windows Server 2003 and Windows Server 2008 operating systems e A minimum 256 MB of RAM is required 512 MB of RAM is recommended e 150 MB of available hard disk space is required e BCM Ele
88. tion 1 Connect the miniature jack of the music source output 3 5 mm mono audio jack to the music source input on the BCM450 main unit BCM450 Music jack 3 5 mm mono audio jack Music source Sleeve Tip Music signal Ring No connection Sleeve Ground 2 Adjust the volume of the music source to an appropriate level by placing a call and placing it on hold and then adjust the volume at the music source End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Copyright 2006 2009 Nortel Networks LAN connection Connect the LAN cables to provide LAN access to your system and to enable connection of IP devices to the LAN through the BCM450 main unit LAN connection procedures This task flow shows you the sequence of procedures you perform to connect your BCM450 system to the LAN To link to any procedures go to LAN connection navigation Figure 14 LAN connection procedures Connecting the main unit to the LAN Connecting IP devices to the LAN Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 76 LAN connection LAN connection navigation e Connecting the main unit to the LAN page 76 e Connecting IP devices to the LAN page 76 Connecting the main unit to the LAN
89. ty system installation page 82 e 1T7406e cordless telephone installation page 82 Installing an emergency telephone You can use an emergency telephone to make calls when no power is going to the BCM450 system You can connect an emergency telephone to every CTM GATM installed in your BCM450 system Prerequisites e ACTM GATM MBM installed in your BCM450 system For more information about installing MBMs see MBM installation page 43 e A single line analog telephone is required Procedure steps Step Action 1 Connect a single line analog telephone to the auxiliary port on the CTM GATM 2 Connect an analog PSTN line cable to the line 1 port of the CTM GATM Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 82 Telephone installation End IP phone installation Configure the system to automatically assign DNs to the Nortel IP Phones If you choose to manually assign DNs choose DNs from unused DNs in the digital range However port numbers are assigned from DS30 01 ports 0101 0132 first then from DS30 08 if ports are available and DS30 07 if the system uses a 3 5 DS30 split If no ports are available on those DS30 blocks the system can assign digital set port numbers Also ensure that you do not assign DNs that are assigned to Call Center mailboxes CDNs Mobility system installation All radi
90. u install your BCM450 system you must ensure that your site and hardware meet the environmental electrical and site telephony requirements Navigation e Environmental requirements e Electrical requirements e Site telephony wiring requirements Environmental requirements Your site must meet the following environmental requirements The installation area must be e aminimum of 4 m 13 ft from equipment such as photocopiers electrical motors and other equipment that produces electromagnetic radio frequency and electrostatic interference e within 1 5 m 5 ft of a three wire grounded electrical outlet e clean dry well ventilated and free of traffic and excess dust e within the temperature range of 5 C and 50 C 40 F and 120 F e from 20 to 80 noncondensing relative humidity e structurally strong and with enough space to support the BCM450 units e a minimum of 46 cm 18 in from the floor Attention The installation area must be of sufficient height from the floor to prevent water damage Electrical requirements Your site must meet the following electrical requirements Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 104 Preinstallation reference Power must be supplied from a nonswitched unobstructed outlet within 1 5 m 5 ft of the BCM450 units If you use a power bar the total length o
91. u the sequence of procedures you perform to install an MBM in a main unit or an expansion cabinet To link to any procedure go to MBM installation procedures page 44 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 44 MBM installation Figure 9 MBM installation procedures Installing MBM in the expansion cabinet Installing MBM in main unit Configuring the MBM in Bement Setting MBM dip htanager and switches setting the DIP switches Installing the MBM in the main unit Configuring the Installing the MBM MBM in Bement in the expansion Manager cabinet MBM installation navigation e Configuring the G4x16 or G8x16 DIP switches page 45 e Configuring the GASM DIP switches page 46 e Configuring the GATM DIP switches page 46 e To connect the fiber cables page 48 e Configuring MBMs for main unit installation page 50 e Fiber expansion module configuration page 47 e Configuring MBMs for expansion cabinet installation page 51 e Installing an MBM in the main unit or an expansion cabinet page 52 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks MBM installation 45 Configuring the G4x16 or G8x16 DIP switches Use this procedure to configure the DIP switches before you install the G4
92. u the sequence of tasks you perform to install a main unit To link to any tasks go to BCM450 main unit installation navigation page 26 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 26 BCM450 main unit installation Figure 4 BCM450 main unit installation tasks Equipment No lin unit desktop rack installation Yes Min unit rack in unit wall mount installation mount installation BCM450 main unit installation navigation e Installing the BCM450 main unit on a rack page 27 e BCM450 main unit wall mount installation page 31 e BCM450 main unit desktop installation page 35 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Installing the BCM450 main unit on a rack BCM450 main unit rack mount installation procedures Attach the rack mount brackets to the BCM450 main unit Prerequisites e Use only the screws supplied with the rack mount bracket Other screws can damage the BCM450 main unit Procedure steps Step Action 1 Place the BCM450 main unit on a flat clean surface 2 Align the screw holes between the BCM450 main unit and the right rack mount bracket 3 Fasten the bracket to the BCM450 main unit using four screws Nortel Business Communications Manager 450 1 0 Installation
93. x16 or G8x16 MBM into the main unit Prerequisites e For information about lines and DNs settings for the G4x16 and G8x16 MBMs see G4x16 and G8x16 wiring chart page 137 Procedure steps Step Action 1 Locate the Module Select and Mode Country Select DIP switches at the rear of the G4x16 or G8x16 MBM Rear of MBM or LOT Module Select Mode Country Select 2 Configure the Module Select DIP switches on the left side at the rear of the module to on up 3 Configure the Mode Country Select DIP switches on the right side at the rear of the module to off down The G4x16 and G8x16 MBMs automatically download the country profiles End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 46 MBM installation Configuring the GASM DIP switches Use the procedure to configure the DIP switches before you install the GASM into the main unit Prerequisites e For information about the GASM DIP switch settings see GASM DIP switch configuration page 107 Procedure steps Step Action 1 Locate the Module Select and Mode Country Select DIP switches at the rear of the GASM Rear of MBM 12345 op ALL LL Module Select Mode Country Select 2 Configure the Module Select DIP switches on the left side at the rear of the module to on up 3 Configure the Mode Se
94. ystem NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 138 Wiring charts reference The analog telephones lines connect to the G4x16 or G8x16 through the lower RJ 21 amphenol connector on the front of the MBM To view the G4x16 G8x16 connectors see Figure 31 G4x16 G8x16 connectors page 138 Figure 31 G4x16 G8x16 connectors RJ 21 amphenol connector for 16 digital telephones RJ 21 amphenol connector for 4 or 8 analog PSTN lines Power Status RJ 21 pin out The digital telephones such as the Business Series Telephones connect to the upper RJ 21 amphenol connector on the front of the G4x16 or G8x16 MBM DSM16 and DSM32 wiring chart Digital telephones such as the Business Series Telephones connect to the Digital Station Module DSM16 or DSM32 through the RJ 21 connectors on the front of the media bay module The DSM16 has a single RJ 21 connector and the DSM32 has two RJ 21 connectors To view the DSM16 and DSM32 connectors see Figure 32 DSM16 and DSM32 RJ 21 connectors page 139 Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks Wiring charts reference 139 Figure 32 DSM16 and DSM32 RJ 21 connectors DSM16 DSM32 Il e elli eM i atus Power Status RJ 21 connector RJ 21 connectors 9 Power 1 25 Taena 26 50 RJ 21 pin ou
95. ystem plug the DIN connector of the power supply cord into the power supply connector receptacle 6 Plug the adapter into a standard AC outlet End Mounting the ATA2 to a wall After you connect the ATA2 you can mount it on a wall Prerequisites e You require 2 4 mm 8 screws e When using 0 5mm wire 24 AWG select a location within 800 m 2600 ft of the BCM450 main unit e Allow 12 5 cm 5 in clearance for the line jack terminal jack and power supply connector Procedure steps Step Action 1 Screw two 4 mm 8 screws into the wall 130 mm 5 1 4 in away from each other Leave 6 mm 1 4 in of the two screws showing 2 Align the slots at the back of the ATA2 unit over the screws Push the unit against the wall The line jack terminal jack and power supply connector must be at the top of the ATA2 End Nortel Business Communications Manager 450 1 0 Installation System NN40160 301 01 04 Standard July 2009 Copyright 2006 2009 Nortel Networks 88 Analog terminal adapter installation Testing insertion loss measurement from the CO to the analog device The maximum loss for ATA2 to Central Office CO configuration must not exceed 10 dB and must be greater than 10 dB Measure the total insertion loss between the CO and analog device by using standard dial up test lines with a transmission test set Prerequisites e You will need a transmission test set for exam

Download Pdf Manuals

image

Related Search

Related Contents

Little Dipper Processor    SubBass  Operational Manual - The Official Tsurumi Pump Store  4. Système de lubrification  Betriebsanleitung Parflare ECO  全項一括 (PDF 4.5MB)    Le compostage en collectif, mode d`emploi  Operating Instructions - ACS-CONTROL  

Copyright © All rights reserved.
Failed to retrieve file