Avaya Auto Voice VLAN Detection and Configuration SMB Business Ethernet Switch 50 User's Manual

image

Contents

1. 2 About this DOCUMENT 1 22200 c 3 Table Of Contents Aanes e 4 Appendix A Nortel IP Phone Configuration cccccsseccsseeeeeeeeeeenesesneeeneneeeseaeseseaeenseeeeeseeesnaesaseenenseaeees 15 List of Acronyms iie euenire Coumecec to doter ec suede cteeubedactedenvucte seedeupeceetesecatedestetadects 18 Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 4 Technical Note Auto Voice VLAN Detection and Configuration Introduction This application note describes the procedure to enable and configure the Auto Voice VLAN Detection and Configuration feature on the BES50 switches With this feature when connecting the BES50 to a compatible Nortel IP phone the BES50 switch automatically detects the presence of the IP phone and assigns the appropriate VLAN membership to its Ethernet port This is achieved by the Link Layer Discovery Protocol message exchange between the BES50 switch and the IP phone The IP phone learns the voice VLAN membership information carried in the LLDP messages and configures its Ethernet port accordingly The BES50 switch expects Ethernet frames originated from the IP phone are tagged with the appropriate VLAN ID and it also tags all outgoing frames towards the IP phone with the same voice VLAN ID Software Firmware Lineup The Auto Voice VLAN Detection and Configuration feature on
2. Access RW gt Summary Auto Device Detection Port Configuration Submit Q gt Configuration Trunk gt Statistics 1 None F meo I oul 802 1AB e pplications gt Spanning Tree 2 None T Enabled M oui 802 1AB fe 20 3 None e Enabled Iv oul 802 148 fe gt Priority 4 Non Enabled Iv oui 802 1AB e gt QoS 5 Auto Enabled F OUI vi 802 1AB fe gt Address Table V Auto Device Detection 6 None 7 T Enabled M OUI l 8021AB o ii irn 7 None s T Enabled Iv oul F 802 148 e obal Settings Port Configuration 8 None gt Enabled Iv oui 802148 fe diis m 9 None z T Enabled M oul T 802 148 fe pplication Filtering e SNIP 10 None v Enabled Iv oui 802 1AB fe V Administration 11 None gt T Enabled Iv OUI l 802 1AB e System Information Poca 12 None z I Enabled IV oul 80214AB fe Cable Test 13 None x Enabled Iv oui 802 148 e 2s i gt pu 14 None z Enabled IV oul 802 148 b 7 Reset 15 None gt T Enabled M oul l 802 1AB fe gt Support 16 None gt Enabled Iv oui I 802 1AB fe 7 None gt T Enabled Iv OUI 802 1AB fe 18 None z T Enabled M oul l 8021AB e 19 None z T Enabled M OUI l 8021AB e z Copyright 2006 Nortel Inc All rights reserved Done Step 5 Connect IP Phone to BES50 Connect a compatible Nortel IP phone to the port with auto voice VLAN detection enabled e g port 5 in the previous example Step 6 Check Auto Voice VLAN Detection Status
3. e Select and press the Query button e Check and ensure that device is discovered as Nortel IP phone and the phone firmware version is correct Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 12 Technical Note Auto Voice VLAN Detection and Configuration hi ela Contact Applications gt LLDP gt Remote Information Detail Access RW gt summary LLDP Remote Device Information Q gt Configuration c c gt Statistics Interface Pon 5 Trunk V Applications Query gt Spanning Tree gt VLAN Local Port 5 V LLDP Chassis Type Network Address Configuration Chassis ID 01 C0 A48 64 65 00 Port Configuration Port Type MAC Address gt E Port Description Nortel IP Phone Remote Port Information Borel 00 0A E4 04 DE 64 Remote Trunk Information System Name Remote Information Detail System Description Nortel IP Telephone 2004 Firmware 0604DBG 9 Device Statistics System Capabilities Supported Bridge Telephone E 9 Device Statistics Detail System Capabilities Enabled Telephone a Management Address gt Address Table VLAN ID gt Auto Device Detection Port And Protocol VLAN ID gt IGMP VLAN Name Application Filtering Protocol Identity Hex 88 CC SNTP MAC PHY Configuration Status Auto Neg Y M Administration Supported ES Wi System Infarmation MAC PHY Configuration Status Auto Neg Quick Start Enabled Yes Cable Test MAC PHY Configuration Status Auto Neg cc gp Advertis
4. Configuration Port Configuration Trunk Configuration Local Information Remote Port Information Remote Trunk Information Remote Information Detail Device Statistics Device Statistics Detail gt Priority gt aos gt Address Table gt Auto Device Detection gt IGMP Application Filtering SNTP V Administration System Information Quick Start Cable Test Applications gt LLDP gt Configuration LLDP Global Configuration Settings Transmission Interval 5 32768 30 seconds Hold time Multiplier 2 10 Delay Interval 0 8192 Reinitialization Delay 0 10 Notification Interval 0 3600 4 P seconds E 2 seconds Js seconds Note The Transmission Interval must be greater than or equal to 4 Delay Interval Copyright 2006 NortelInc All rights reserved Done ex cz Q e Gu Step 3 Enable Global Voice VLAN Detection In order to use the auto voice VLAN detection this feature must first be enabled on a global basis From the WebUI navigate to the Applications gt Auto Device Detection gt Voice VLAN gt Global Settings panel Selected the checkbox labeled Auto Detection Status Fill the Voice VLAN ID created in Step 1 in our previous example VLAN ID 10 Select and press the Submit button While this configuration step is identical for both BESBOFE and BES50GE switches the WebUI panels of these two switches are slightly different The following screens
5. LLDP Enable Y DHCP Y DHCP Full Speed A Cfg XAS N Voice 802 1Q Y VOICE VLAN Y VLAN Cfg Auto LLDP Med N LLDP VLAN Y DHCP Y VLAN Filter N Media Bits 8 Leave data port settings at default enabled no data Vlan After going through all the settings the IP phone will restart NORTEL IP Phone 1120E 1140E Power cycle the IP phone Wait until you hear the power on music tone When you see the Nortel name label press the four function keys under the display individually in order from left to right The login password is 26567 738 Configure the phone attributes as indicated below To navigate press the right or left sides of the 4 position rocker switch Press middle button on the rocker switch to edit a setting To change a value press the top or bottom of the 4 position rocker switch n some case LLDP support may depend on the IP phone firmware version Please check phone firmware version as well to ensure LLDP capability is supported Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 15 Technical Note Auto Voice VLAN Detection and Configuration Enable 802 1x EAP Not Checked Enable 802 1ab LLDP Checked DHCP Full Disable Voice 802 1Q Not Checked Network Port Speed Auto Voice Vlan LLDP VLAN Name VLAN Filter Not Checked Control Priority Bits Auto Media Priority Bits Auto 6 Leave data port settings at default enabled no data Vlan 7 After going through all the settings press Apply and R
6. the BES50 switches is designed to work with designated Nortel IP phone Please check software or firmware version of the Nortel IP phone and the BES50 switches to ensure this feature is supported The following BES50 switches and Nortel IP phones were tested in this application note Device Model Firmware Software BES50 FE BES50FE 24T PWR 1 0 3 0 BES50 GE BES50GE 24T PWR 1 0 5 0 IP Phone 2001 NTDU90 0604DBG IP Phone 2002 NTDU91 0604DAD IP Phone 2004 NTDU92 0604DBG IP Phone 1120E NTYSO3 0624C4N IP Phone 1140E NTYS05 0625C4D IP Phone 1220 NTYS19 062AC57 IP Phone 1230 NTYS20 062AC57 Please ensure the BES50 switches are using at least the software version specified in this application note or later software version Consult the document Using the Nortel Business Ethernet Switch 50 Series NN47924 301 for the detailed software upgrade procedures Step 1 Create a VLAN with the name voice e From the WebUI navigate to the Applications gt VLAN gt 802 1Q VLAN gt Static List panel e Create a new VLAN with the name voice NOTE all lower case without the quote and select an unused VLAN ID between 0 4094 e Select and press the Submit button Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 5 Technical Note Auto Voice VLAN Detection and Configuration hi ela Contact Access RW gt Summary VLAN Static List gt Configuration Eee ee us
7. AN 1 Unit 1 Port 5 Dynamic Current Dynamic Address Table Copyright 2006 Nortel Inc All rights reserved Dons Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 14 Technical Note Auto Voice VLAN Detection and Configuration Appendix A Nortel IP Phone Configuration The Auto Voice VLAN Detection and Configuration feature on the BES50 switches is designed to work with designated Nortel IP phone The IP phone must support Link Layer Discovery Protocol LLDP able to learn voice VLAN membership information carried in the LLDP messages and have the capability to configure its Ethernet port according to the received VLAN information This appendix provides examples of how to configure specific models of Nortel IP phone to take advantage of the BES50 Auto Voice VLAN Detection and Configuration feature Please refer to the respective user manual of relevant Nortel IP phone for more detailed configuration information NORTEL IP Phone 1220 1230 Qc NOOR 8 9 Power cycle the IP phone Wait until you hear the power on music tone When you see the Nortel name label press the four function keys under the display individually in order from left to right The first password is 2264 Select 3 Network Configuration The second password is 26567 738 Configure the phone attributes as indicated below Press OK to navigate to the next attribute Press backspace to change a setting EAP Enable N
8. After the IP phone is connected wait for the IP phone and the BES50 switch discover each other The following simple steps can be used to check whether the Voice VLAN is automatically configured when the IP phone is connected VLAN Membership e From the WebUI navigate to the Applications gt VLAN gt 802 1Q VLAN Current Table panel e From the pull down menu select the voice VLAN ID in our previous example the VLAN ID is 10 e Check and ensure that the port in which the IP phone is connected to in our previous example port 5 is included in the Egress Ports list but not included in the Untagged Ports list Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 11 Technical Note Auto Voice VLAN Detection and Configuration NORTEL Contact Applications gt VLAN gt 802 1Q VLAN gt Current Table Access RW gt summary VLAN Current Table 2 gt Configuration VLAN ID 10 gt Statistics V Applications gt Spanning Tree Up Time at Creation OdOh8 min 57 s V VLAN Status Permanent V 802 10 VLAN SICVRP Status Egress Ports Untagged Ports Basic Information Current Table Uniti Ports none Static List ir ir Copyright 2006 NorteLInc All rights reserved IP phone LLDP information e From the WebUI navigate to the Applications gt LLDP gt Remote Information Detail panel e From the pull down menu select the port in which the IP phone is connected to in our previous example port 5
9. Technical Note Auto Voice VLAN Detection and Configuration SMB Business Ethernet Switch 50 Version NN70000 002 issue 1 00 Date July 08 2008 Status Released Copyright 2008 Nortel Networks All rights reserved The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is the property of Nortel Networks Technical Note Auto Voice VLAN Detection and Configuration Revision History Revision Issue Date Document Change Description Ver Iss Status 0 01 2008 07 08 Released First external release version Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks Technical Note Auto Voice VLAN Detection and Configuration About this Document This document is intended for people responsible for deployment and support of the Nortel Business Ethernet Switch 50 This may include Customer System Engineering Channel Partner Engineering Nortel Solutions Engineering Knowledge Systems Education Services Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 3 Technical Note Auto Voice VLAN Detection and Configuration Table of Contents RODA
10. d Voice VLAN ID 40 Voice VLAN Aging Time Mins Telephony OUI Lists fi 440 ex cz Q Ge Qu ex cz Q Hew none il Version NN70000 002 issue 1 00 Add Remove Copyright 2006 NortelInc Al rights reserved Telephony OUI Mask Description Copyright 2008 Nortel Networks FF FF FF 00 00 00 7 p Qu Technical Note Auto Voice VLAN Detection and Configuration Step 4 Enable Per Port Voice VLAN Detection The final configuration step is to enable voice VLAN detection on the ports in which IP phones may connect to While both the BES50FE and BES50GE switch need to enable the same Voice VLAN Mode attribute the WebUI panels of these two switches are slightly different The following screenshot illustrates the configuration procedure for BES50GE e From the WebUI navigate to the Applications gt Auto Device Detection gt Voice VLAN gt Port Configuration panel e Move to the row corresponding to the target Ethernet port E g for port 5 move to the row labeled 5 e From the pull down menu of the Voice VLAN Mode select Auto mode e Select and press the Submit button NORTEL Contact Applications gt Auto Device Detection gt Voice VLAN gt Port Configuration Access RW gt Summary Auto Device Detection Port Configuration Submit gt Configuration gt Statistics 1 None z B ieil e V Applications gt Spanning Tree 2 None gt E
11. ed Cap Hex MAC PHY Configuration Status MAU Type 15 gl Copyright 2006 NortelInc All rights reserved Done IP phone MAC address e From the WebUI navigate to the Applications gt Address Table gt Dynamic Addresses panel e Select the Interface checkbox and click on the radio box labeled Port e From the interface port pull down menu select the port in which the IP phone is connected to in our previous example port 5 e Select and press the Query button e Check and ensure that MAC address of the Nortel IP phone is discovered and associated with the correct Ethernet port in our previous example port 5 Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 13 Technical Note Auto Voice VLAN Detection and Configuration NQRTEL Contact Access RW gt Summary gt Configuration gt Statistics V Applications gt Spanning Tree gt VLAN gt LLDP gt Priority gt aos V Address Table Address Aging Static Addresses Dynamic Addresses gt Auto Device Detection gt IGMP Application Filtering SNTP V Administration System Information Quick Start Cable Test gt Security 7 Logout 7 Reset gt Support Applications gt Address Table gt Dynamic Addresses Dynamic Addresses Q Query by Iv Interface pon s v C Trunk v I MAC Address T VLAN hos Address Table Sort Key Address z Dynamic Address Table Dynamic Address Counts 1 00 0A E4 0A DE 64 VL
12. eset to restart the phone NORTEL IP Phone 2001 1 Power cycle the IP phone When you see the Nortel Networks name label press the four keys under the display individually in order from left to right 3 Configure the phone attributes as indicated below Press OK to go to the next attribute Press backspace to change a setting EAP Enable N LLDP Enable Y DHCP Y Speed Auto Cfg XAS N Voice 802 1Q Y VOICE VLAN Y VLAN Cfg Auto LLDP Med N LLDP VLAN Y VLANFILTER N Ctrl pBits Auto Media pBits Auto Data VLAN N GARP Ignore N PSK SRTP N 4 After going through all the settings the set will restart NORTEL IP Phone 2002 2004 2 Power cycle the IP phone 3 When you see the Nortel Networks name label press the four keys under the display individually in order from left to right 4 Configure the phone attributes as indicated below Press OK to go to the next attribute Press backspace to change a setting EAP Enable N LLDP Enable Y DHCP Y Cached IP N DHCP Full Cfg XAS N VOICE VLAN Y Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 16 Technical Note Auto Voice VLAN Detection and Configuration VLAN Cfg Auto LLDP Med N LLDP VLAN Y VLANFILTER N PC Port Off DUPLEX Auto GARP Ignore N PSK SRTP N 5 After going through all the settings the set will restart Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 17 Technical Note Auto Voice VLAN Detection and Config
13. hot illustrates the BES50GE WebUI panel Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks NORTEL Contact Access RW gt Summary gt Configuration gt Statistics V Applications gt Spanning Tree gt VLAN gt LLDP gt Priority gt aos gt Address Table V Auto Device Detection V Voice VLAN Global Settings Port Configuration gt IGMP Application Filtering SNTP V Administration System Information Quick Start Cable Test gt Security 7 Logout 7 Reset gt Support Applications gt Auto Device Detection gt Voice VLAN gt Global Settings Technical Note Auto Voice VLAN Detection and Configuration Voice VLAN Global Settings Auto Detection Status Voice VLAN ID Voice VLAN Aging Time Mins W Enabled Copyright 2006 NorteLInc All rights reserved The following screenshot illustrates the BES50FE WebUI panel ale Contact Access RW gt Summary gt Configuration gt Statistics V Applications gt Spanning Tree gt VLAN gt LLDP gt Priority gt aos gt Address Table V Auto Device Detection V Voice VLAN Global Settings Port Configuration gt IGMP Application Filtering SNTP V Administration System Information Quick Start Cable Test gt Security 7 Logout 7 Reset gt Support Applications gt Auto Device Detection gt Voice VLAN gt Global Settings Voice VLAN Global Settings Auto Detection Status Enable
14. nabled o x Hee 3 None v I Enabled e gt Priority 4 None v Enabled e gt ore DF E k gt Address Table V Auto Device Detection E None z T Enabled fe dun 7 None v T Enabled e obal Settings Port Configuration 8 None E Enabled f MEUM NN 9 None v T Enabled e Application Filtering e SNTP 10 None v I Enabled e V Administration 11 None v Enabled e System Information Quick Start 12 None x lI Enabled e Cable Test 13 None v I Enabled e yis 14 None v I Enabled e Reset 15 None v Enabled e gt Support 16 None z Tl Enabled e ig None v Enabled e 18 None 7 Enabled e 18 None v I Enabled e Copyright 2006 Nortel Inc All rights reserved Done The following screenshot illustrates the configuration procedure for BES5OFE e From the WebUI navigate to the Applications gt Auto Device Detection gt Voice VLAN gt Port Configuration panel Move to the row corresponding to the target Ethernet port E g for port 5 move to the row labeled 5 From the pull down menu of the Voice VLAN Mode select Auto mode Under the Discovery Protocol attribute select the checkbox labeled 802 1AB Select and press the Submit button Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 10 Technical Note Auto Voice VLAN Detection and Configuration NORTEL Contact Applications gt Auto Device Detection gt Voice VLAN gt Port Configuration
15. rks Technical Note Auto Voice VLAN Detection and Configuration hi ela Contact Applications gt VLAN gt 802 1Q VLAN gt Static List Access RW gt summary VLAN Static List Q gt Configuration E eee gt Statistics 1 Defaultvlan Enabled VLAN ID 1 4094 V Applications 10 voice Enabled dd gt Spanning Tree VLAN Name VAN Remove V 802 10 VLAN zd Status T Enabled GVRP Status Basic Information Reload Current Table Static List Static Table Static Membership by Por Port Configuration Trunk Configuration gt LLDP gt Priority gt QoS gt Address Table gt Auto Device Detection gt IGMP Application Filtering SNTP V Administration System Information Quick Start Cable Test Copyright 2006 NortelInc All rights reserved bee L Step 2 Enable Link Layer Discovery Protocol LLDP The Auto Voice VLAN detection feature uses LLDP for the IP phone and the BES50 to discover each other and to exchange voice VLAN information e From the WebUl navigate to the Applications gt LLDP gt Configuration panel e Selected the checkbox labeled Enabled e Select and press the Submit button Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 7 Technical Note Auto Voice VLAN Detection and Configuration NORTEL Contact Access RW gt Summary gt Configuration gt Statistics V Applications gt Spanning Tree gt VLAN V LLDP
16. se mmm gt Statistics 1 Defaultvian Enabled V Applications Add gt Spanning Tree V VLAN Remove M 802 10 VLAN z Status GVRP Status Basic Information Current Table Static List Static Table Static Membership by Por Port Configuration Trunk Configuration gt LLDP gt Priority gt aos gt Address Table gt Auto Device Detection gt IGMP Application Filtering SNTP V Administration System Information Quick Start Cable Test NORTEL Contact Access RW gt Summary VLAN Static List gt Configuration gt Statistics V Applications gt Spanning Tree V VLAN V 802 10 VLAN GVRP Status Basic Information Current Table Static List Static Table Static Membership by Por Port Configuration Trunk Configuration gt LLDP gt Priority gt aos gt Address Table gt Auto Device Detection gt IGMP Application Filtering SNTP V Administration System Information Quick Start Cable Test Applications gt VLAN gt 802 1Q VLAN gt Static List Applications gt VLAN gt 802 1Q VLAN gt Static List 1 DefaultVlan Enabled 4 Copyright 2006 NortelInc All rights reserved YLAN Name zi E Status Copyright 2006 Nortel Inc All rights reserved VLAN ID 1 4094 VLAN Name VLAN ID 1 4094 a Q Reload T roie Reload Version NN70000 002 issue 1 00 Copyright 2008 Nortel Netwo
17. uration List of Acronyms BES Nortel Networks Business Ethernet Switch Version NN70000 002 issue 1 00 Copyright 2008 Nortel Networks 18