Home
Aube Technologies TH131-15S User's Manual
Contents
1. 5 C 59 F to 95 F Accuracy 0 2 C 0 36 F Storage 20 C to 50 4 F to 120 F Heating cycle length 15 seconds Software Class A Controller Electronic Size H W D e TH131 78 9 x 78 9 x 16 3 mm 3 1 x 3 1 x 0 64 in e TH133 78 9 x 78 9 x 18 mm 3 1 x 3 1 x 0 71 in TH131 15S amp TH133 15S V Warranty AUBE TECHNOLOGIES INC THREE 3 YEAR LIMITED WARRANTY Aube warrants this product excluding battery to be free from defects in the workmanship or materials under normal use and service for a period of three 3 years from the date of purchase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions Aube shall repair or replace it at Aube s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or it contact Aube Aube will make the determination whether the product should be returned or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Aube s sole responsibility shall be to repair or replace the product within the terms stated above AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDI
2. NG ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some regions do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE THREE YEAR DURATION OF THIS WARRANTY Some regions do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from region to region ZA Customer Assistance If you have any questions about the product installation or operation or concerning the warranty contact us at il 705 Montrichard 10 rue Amp re Saint Jean sur Richelieu 95500 Gonesse Quebec Canada J2X 5K8 France Tel 450 358 4600 Tel 33 0 1 34 07 99 00 Toll Free 1 800 831 AUBE Fax 33 0 1340799 19 Fax 450 358 4650 Email advaube comintes com Email aube service honeywell com For more information on our products go to www aubetech com 400 131 022 A 1 11 06 2 2 a technologies Applications This document describes the connections when the PB130 024T power base is used on any TH13x 15S ser
3. Position A UP A AF AF UP A AF F DOWN F Position the switch on the back of the control module according to your application 3 2 Minimum and Maximum Limits TH131 15S only Use the two potentiometers on the back of the control module to set the minimum and maximum tem perature limits Depending on your application the potentiometers limit the following temperature gt ambient temperature A gt floor temperature F or AF Use a flat tip screwdriver to rotate the potentiometers until the notch points to the desired temperature limit 400 131 022 A 1 11 06 1 2 Operation 4 1 Temperature Adjustment TH131 15S Use the dial on the front of the thermostat to set the desired tempera ture NOTE If the dial is placed at a temperature beyond the high or low temperature limit the temperature will be maintained at that limit see section 3 2 TH133 15S Remove the control module from the base and use the dial on the back of the control module to set the desired temperature 4 2 On Off Switch TH131 15S only Use the On Off switch to turn the thermostat Off when it is not used e g in the summer Specifications Setpoint range 7 C 15 C to 35 C 45 F 59 F to 95 F Minimum temperature limit 5 C to 25 C 41 F to 77 F Maximum temperature limit 15 C to 3
4. aube technologies TH131 155 amp TH133 158 User Guide Electronic Thermostat WARNING This thermostat provides fast cycling control and MUST therefore be used ONLY with solid state relays The use of electromechani cal relays will result in reduced life expectancy and possibility of overheating of these devices TH131 15S Pilot wire indicator Heating indicator Europe only On Off switch Temperature selection dial TH133 15S Rear View Front View NOTE Even if the following illustrations show the TH131 model only they can also apply to the TH133 model Description This user guide covers the following thermostat models e TH131 15S A F AF e TH133 15S A F AF The TH131 15S model is designed for residential applications whereas the TH133 model is designed for public areas as its controls are hidden and thus protected against unauthorized access Both models can be configured for the following applications Type Application A Controls the ambient room temperature F Controls the floor temperature AF Controls the ambient temperature and limits the floor temperature TH131 15S amp TH133 15S Installation Control Module Power Base NOTE Keep the thermostat s air vents clean and free from obstruc tions Configuration 3 1 Application Types Type Switch
5. ies thermostat When used on a TH13x 15S thermostat this low voltage power base must be connected to the line voltage load using a solid state relay SSR The PB130 024T is compatible with most solid state relays however the following Aube relays are optimized for use with this power base e RT850 solid state relay SSR e RT850T solid state relay SSR with built in 24 V transformer Supplied Parts One 1 power base Two 2 plastic anchors Two 2 mounting screws Installation Guidelines gt For a new installation choose a location about 1 5 m 5 ft above the floor gt The thermostat must be installed on an inside wall facing the heating system except for floor heating systems gt Avoid locations where there are air drafts top of staircase air outlet dead air spots behind a door direct sunlight or concealed chimney or stove pipes except for floor heating systems Installation Procedure The installation must be carried out by an electrician and must comply to local electrical codes Turn off power to the heating system at the main electrical panel to avoid electrical shock Wire the base according to your application See typical wiring diagrams in sections 4 1 and 4 2 On NUL Fora floor heating system installation con nect the floor sensor between the S and R ter minals rn I S O O S OS Secure the base to the wall using the provided screws and
6. wall anchors Configure the switches located on the control module if any Refer to the user guide Install the control module onto the base Apply power to the heating system O00 O Verify the installation by checking that the heating system can be turned On or Off using the thermostat PB130 024T PB130 0241 Installation Instructions 24 V Low Voltage Power Base 4 1 Single SSR with Built in Transformer RT850T PB130 024T C W R Electrical Panel Blue Red L2 L1 Black Heater 4 2 Multiple SSRs with External Transformer PB130 024T L1 o gt Electrical T CWRS Panel AILS OS B z L2 Black VDC 4 External 24 V VAC e Transformer OQ Red COM VDC VAC COM Heater Technical Specifications Maximum load 0 5 A 24 VAC Operating temperature 0 C to 50 C 82 F to 122 F Storage 20 C to 50 C 4 F to 122 F Size H gt W D 75 x 75 x 13 mm 2 9 x 2 9 x 0 5 in Wire gauge 14 to 22 AWG 400 130 011 A 1 11 06 1 1