Contents
1. until the beginning of the next program Programming You can set up to 7 programs To set a program you need to enter its start time ON and its end time OFF 1 Pry the switch door open using a small screwdriver Press the PGM button to display a program and its On or Off time For example when you first press PGM program number 1 P1 and its On time ON will appear will appear instead of the time if the program is not set inactive Press the DAY button to select the day to which you want to apply the program NOTE If you want to apply the program to every day of the week press DAY until all the days are displayed This still counts as 1 program not 7 ON v ON P i MO TU WE TH FR SA SU 400 033 001 C 30 11 06 1 2 Press the HOUR and MIN buttons to set the ON time time when you want the lights to turn on If you have selected the 12 hour format ensure that PM appears on the screen when an afternoon time is displayed After you have programmed the ON time press the PGM button to display the OFF time time when you want the lights to turn off Repeat steps 3 through 5 to program the OFF time If the program ON time is set for every day 3 R of the week the program OFF time will automatically be set for every day ee To set another program repeat steps 2 through 6 Programs that are not set will remain inactive Pre
2. amages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE THREE YEAR DURATION OF THIS WARRANTY Some provinces states or regions do not allow limita tions on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from one province state or region to another FA Customer Assistance If you have any questions on the product installation or operation contact us at 705 Montrichard Avenue Saint Jean sur Richelieu Quebec J2X 5K8 Canada Tel 450 358 4600 Toll free 1 800 831 AUBE Fax 450 358 4650 Email aube service honeywell com For more information on our products go to www aubetech com 400 033 001 C 30 11 06 2 2
3. aube technologies Applications The TI033 programmable wall switch has been designed to control lightings and motors Load type Maximum load Examples incandescent lights halogen lights block heater 2400 W Resistive load 20 A 120 V e fluorescent lights 2400 W compact fluorescent lights CFL 20A 120V sodium lamps electronic ballasts Inductive load pool filter pumps Motor 1 hp z Fans installation NOTE This switch cannot be used if there are not at least 2 white wires joined by a connector inside the electrical box O cut power at the circuit breaker to avoid electric shock Remove the existing switch install the new switch as shown in the diagram below 4 Apply power at the circuit breaker black C ran white neutral 120 VAC black line Power On 1 Pry the switch door open from the bottom using a small screwdriver Ensure the ON OFF selector is set a to ON H e H Control 4 Reset the switch using a paper clip ce n t 0 00 and MO will flash meim selector If the display is blank e Ensure the ON OFF selector is properly engaged in the ON posi tion Push it to the right using a small screwdriver T1033 T1033 Installation and User Guide Programmable Wall Switch Settin
4. d by a rechargeable battery The screen is blank during the power outage Certifications CSA amp UL T1033 V Warranty AUBE warrants this product excluding battery to be free from defects in the workmanship or materials under normal use and ser vice for a period of three 3 years from the date of purchase by the consumer If at any time during the warranty period the product is determined to be defective or malfunctions AUBE shall repair or replace it at AUBE s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii contact AUBE AUBE will make the determination whether the product should be returned or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by AUBE that the defect or mal function was caused by damage which occurred while the product was in the possession of a consumer AUBE s sole responsibility shall be to repair or replace the product within the terms stated above AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCI DENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WAR RANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some provinces states or regions do not allow the exclusion or limitation of incidental or consequential d
5. g the Clock NOTE The switch displays the time in 24 hour format by default or following a reset To change to 12 hour format or vice versa proceed as follows a Press one of the control buttons to ensure the MAN or AUTO indicator is displayed b Press the MIN and HOUR buttons simultaneously and brief tly 0 00 display 24 hour 12 00 display 12 hour Set the time using the HOUR and MIN buttons If you have selected the 12 hour format ensure that PM appears on the screen when an afternoon time is displayed Set the day by using the DAY button Press one of the control buttons or close the switch door to return to normal operation Selecting the Operating Mode The programmable switch has 2 operating modes manual MAN and automatic AUTO To switch mode press the switch door for 3 seconds 6 Manual Mode The programmable switch operates as a regular switch Briefly press the switch door to turn the lights ie a 3 M L TU OFF On or Off The mode MAN and state ON or OFF 5 are displayed Automatic Mode The programmable switch follows the programmed schedule The mode AUTO state ON or OFF ee aij and current program number are displayed iM 2 25 To temporarily override the programmed schedule briefly press the switch door The new state ON or OFF will flash to show that this state is temporary The override remains in effect until you press the switch door again or
6. ss one of the control buttons or close the switch door to return to normal operation Clearing a Program Press the PGM button until the desired program is selected Hold the PGM button for 3 seconds appears when the program is erased Troubleshooting e Verify circuit breaker at main panel Ensure the ON OFF selector is at ON e Reset the switch using a paper clip Blank display Faded or irregular Ambient temperature below freezing display point Cannot switch between First press one of the control buttons so 24 hour format and that MAN or AUTO appears on display 12 hour format Programs do not run as expected Make sure the switch is properly pro grammed e Note that indicates an inactive pro gram 00 00 indicates midnight If the switch has been configured for 12 hour format check that PM appears on the left side of the screen when an afternoon time is displayed The switch resets itself The reset is caused by the load Install a without apparent rea snubber AC 130 03 at each relay con son when used to con tactor trol an inductive load such as a relay ora contactor Technical Specifications Supply 120 VAC 50 60 Hz Maximum load 2400 watts resistive or inductive 1 HP motor Operating temperature range 5 F to 122 F 15 C to 50 C Storage temperature range 4 F to 122 F 20 C to 50 C Power outage The programs are protecte
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung 020-100939-02_LIT MAN USR TVC-1700_ES.book Longshine LCS-8141A specifiche tecniche - Virgilio Siti Xoom 1. Package Contents 3. Media Converter Chassis Front Panel 2 X408BV-FHD Manual VIOS. DVDUV0801. Manuel d`utilisation des armoires de stockage au sec Acrylique ESDA Copyright © All rights reserved.