Home

Attwood 6126 User's Manual

image

Contents

1. Potable Water Pump 6126 Mounting Instructions SAVE THESE INSTRUCTIONS Form Number 69239 Rev B 03 11 FEATURES The Potable Water Pump is a rugged small sized fresh water pump used to deliver water to a faucet Ideal for use with the Attwood 6142 Faucet Hand Pump It is made of ABS non corro sive FDA approved plastic Meets U S Coast Guard Safety Standards Sections 33 CFR 183 410 and 183 425 Listed by the International Association of Plumbing and Mechanical Officials IAPMO Attwood marine hardware navigation lighting interior lighting bilge pumps and other marine accessories are specified more than any other brand by America s best known boat manufacturers as original equipment Look to Attwood for quality replacement parts and add on marine accessories CAUTION The Potable Water Pump is designed to pump fresh potable water only It must not be used to pump gasoline or other flammable liquids TOOLS AND MATERIALS REQUIRED 1 Drill and suitable drill bits Screwdriver Wire strippers Four 4 wire connectors or equivalent One 1 in line fuse holder with 2 amp fuse Two 2 10 panhead screws length must not protrude through deck 7 Suitable length of 3 8 I D hose for pump to tank and pump to faucet 8 Four 4 stainless steel screw adjustable hose clamps 9 Additional wire if needed in 16 or 18 gauge size INSTALLATION INSTRUCTIONS 1 Select a suitable location
2. for this pump keeping in mind that it must be a dry area The pump has intake and outlet fittings to fit 3 8 I D soft plastic tubing or 1 4 female pipe thread cut off hose barb if necessary Teflon plumbers tape must be used for all threaded connections and hose clamps for all tubing con nections NOTE This product is designed to be used with the Attwood 6142 3 Way Electric Faucet which includes an integral ON OFF switch However it may also be used with any 12 volt DC water system with an ON OFF switch rated for 2 amps or more serv ice providing that the recommended 2 amp fuse is also used oar OMN 2 After installing the pump connect the pump s black lead wire directly to the 12 volt battery negative connector Connect the pump s brown wire lead to one wire of an in line fuse holder and connect the other fuse holder wire to one lead wire from the Electric Faucet Connect the other Electric Faucet lead wire directly to the 12 volt battery positive connector See Figure 1 Added wire must be 18 gauge or larger An optional power ON OFF switch such as Attwood 7589 or 7563 may be installed as a master switch as shown in Figure 2 The pump may be threaded directly into the tank However this is a centrifugal pump and must be positioned lower than the source of water to operate Do not install on a surface higher than the bottom of your fresh water supply tank NOTE When installing outlet nozzle should al
3. or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state 2003 Attwood Corporation 1016 N Monroe Street Lowell MI 49331 0260 www attwoodmarine com
4. se lack of proper maintenance unauthorized repairs or modifications or other causes not arising out of defects in materials and workmanship Attwood s obligations under this warranty are limited to repair of the product at Attwood s plant or replacement of the product at Attwood s option and at Attwood s expense Any expenses involved in the removal reinstallation or transportation of the product are not covered by this warranty The product must be returned to Attwood s plant at the address indicated above postage prepaid with proof of original purchase including date If Attwood is unable to replace the product and repair is not commercially practicable or cannot be timely made or if the original consumer purchaser is willing to accept a refund in lieu of repair of replacement Attwood may refund the purchase price less an amount for depreciation The acceptance by Attwood of any product returned or any refund provided by Attwood shall not be deemed an admission that the product is defective or in violation of any warranty This warranty is Attwood s only express warranty of this product No implied warranty shall extend beyond one 1 year from the date of original consumer purchase Attwood shall not be liable for any damages for loss of use of this product nor for any other incidental or consequen tial damages costs or expenses Some states do not allow limitations on how long an implied warranty lasts or the exclusion
5. ways be higher than inlet nozzle See Figure 3 Attwood 6142 3 WAY ELECTRIC FAUCET CITY WATER CONNECTION 30 40 PSI FUSE AND PRESSURE HOLDER LIMITING I CHECK TEE VALVE 12 VOLT BATTERY Attwood 6126 POTABLE WATER PUMP FIGURE 1 OPTIONAL MASTER SWITCH INSTALLATION Attwood 7589 or 7563 N TO TO POTABLE BATTERY WATER PUMP FIGURE 2 OUTLET ABOVE INLET OUTLET BELOW INLET INCORRECT CORRECT FIGURE 3 CAUTION This product is not water resistant and must be installed in a dry location Do not use synthetic rubber sealant Silicone RTV etc or any sealant which smells like vinegar to seal the pump or its fittings Use of these materials may cause the pump to crack It is best to use plumbers Teflon tape where required CAUTION ALWAYS protect the pump and the wiring with a 2 amp fuse For 12 volt DC use only m ATTWOOD LIMITED WARRANTY BILGE PUMPS ATTWOOD CORPORATION 1016 North Monroe Lowell Michigan 49331 Attwood warrants to the original consumer purchaser that this Attwood Potable Water Pump will be free from defects in materials and workmanship under normal use and service for a period of one 1 year from the date of original consumer purchase This warranty does not extend to any batteries or fuses used with the pump This limited warranty is not applicable if the pump has been damaged by accident improper installation unreasonable u

Download Pdf Manuals

image

Related Search

Related Contents

Service Manual - Linfotech.co.uk  Nokia N97 Bedienungsanleitung  OLC(T) 20_rev C.2_ EN  Télécharger - Radio Télévision Suisse Romande  Yaesu - FT-8000 user manual    Samsung 22" TV Monitor cu difuzoare încorporate Manual de utilizare  PROCEDURE DI SICUREZZA - Itis Leonardo da Vinci  Guia do Usuário da Impressora em Cores Phaser® 6000/6010  Curtis RCD237UKT User's Manual  