Home

Atlas MLGC240B User's Manual

image

Contents

1. 2051 TEST MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO E3 1 Second OFF then Flip the light switch off for one sec ond then back on to toggle between AUTO and MANUAL MODE Manual mode works only with the ON TIME switch in the 1 5 or 20 position Le back on Mode Switching Summary Move ON TIME Switch to 1 5 or 20 minutes Flip light switch off for one second then If you get confused while switching modes turn the power off for one minute then back on After the calibration time the control will be in the AUTO mode Dual Light Level Control Light comes on half bright for selected time after dusk Off 3 hr 6 hr until dawn If motion is sensed the light turns on full bright for the ON TIME 1 5 or 20 minutes then returns to dim mode 240 028 A 598 1094 01 INSTALLATION For easy installation select an existing light with a wall switch for replacement Wall Mount For under eave installation the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock Eave Mount For eave mount only O Swing the sensor head towards the clamp screw joint O Then rotate the sensor head clockwise 180 so the controls face down af r Controls a Pe Controls lt If the sensor pops ou
2. Damages occurring during transit are not covered by this warranty including UPS shipments To obtain warranty service mail sales receipt as proof of purchase date and a brief explanation of the nature of the defect to the address listed below You will receive by mail a Return Goods Authorization number and full instructions for returning defective merchandise All returned goods must be accompanied by a Return Goods Authorization number issued by Atlas Lighting Products Inc NOTE No other warranty written or verbal is authorized by Atlas Lighting Products Inc This warranty gives you specific legal rights and you may also have other rights which vary from state to state Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above exclusion and limitations may not apply to you For information regarding replacement parts please write to Atlas Lighting Products Inc Attn Customer Service Department P O Box 2348 Burlington NC 27216 4 598 1094 01
3. electrical shock keep lamp holders 30 below horizontal Keep lamps at least 1 2 5 cm from the sensor Do not al low the lamps to block the lens O Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180 from the factory setting When screwing in the floodlamps do not overtighten 598 1094 01 2 TEST AND ADJUSTMENT O Turn on the circuit breaker and light switch NOTE Sensor has about 1 2 minutes warm up period before it will detect motion When first turned on wait about 1 2 minutes O Turn the RANGE control to the mid position DUAL LIGHT LEVEL to OFF and the ON TIME control to the TEST position MAX o ON TIME DUAL LIGHT LEVEL ea cL es O RANGE MINUTES HOUR Bottom of Sensor Avoid aiming the control at Objects that change temperature rapidly such as heating vents and air conditioners These heat sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor 240 8 ft 2 4 m e e 70 ft 100 ft 21 m 30 5 m Boosted Maximum Range Maximum Coverage Angle The detector is most sensitive to motion across its field of view Sensor Least Sensitive Most Sensitive 598 1094 01 O Lo
4. Auto Heat or light from the lamps may be turning the Light Control on and off Reposition the lamps away from the sensor Heat being reflected from other ob jects may be affecting the sensor Reposition sensor Light Control is in the Test mode and warming up Flashing is normal un der these conditions Turn Boost off Light may be leaking through the Dual Light Level is on g floodlamp reflectors Make sure the metal lamp protectors are installed Sensor is detecting its own lights Reposition lamps to keep area be low sensor relatively dark Lights flash once then stay off in Manual Mode FIVE YEAR LIMITED WARRANTY Atlas Lighting Products Inc warrants against defects in materials or workmanship for a period of five years from the date of purchase for use and agrees to repair or at our option replace a defective unit without charge for either parts or labor IMPORTANT This warranty does not cover damage resulting from accident misuse of abuse lack of reasonable care the affixing of any attachment not provided with product alteration of any attachments factory installed loss of parts or subjecting the fixture to any but the specified electrical service This warranty does not cover failure of the bulb due to accidents abuse misuse vandalism power surges and acts of nature such as lightning damage No responsibility is assumed for any special incidental or consequential damages
5. Atlas Lighting Products GUARDIAN rro Z40 SERIES Models MLGC240B MLGC240W Features e Turns on lighting when motion is detected e Automatically turns lighting off e Dual Light Level e Photocell keeps the lighting off during daylight hours e LED indicates motion was sensed day or night This package includes a Lamp Holders 6 Screws 3 sizes included 2 Shells 2 Wire Connectors lt lt Mounting Bolt Q Rubber Plug li Gasket Mounting Strap Plastic Hanger Requirements The Light Control requires 120 volts AC If you want to use Manual Mode the control must be wired through a switch Some codes require installation by a qualified electrician This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations 2003 Atlas Lighting Products Inc OPERATION On Time Works 5 Seconds 1 5 20 min Until Dawn 3 6 Hr to Dawn resets to Auto Mode at dawn Note When first turned on wait about 1 2 minutes for the circuitry to calibrate TEST Day Night Test Auto Manual Accent Put ON TIME switch on the sensor bottom to TEST and the Dual Light Level switch OFF ON TIME DUAL LIGHT LEVEL TEST 1520 Off 3 6 Dusk to Dawn AUTO Put the ON TIME switch inthe 1 5 or ON TIME 20 minute position
6. osen the clamp screw in Clamp the sensor ball joint and gen si Screw tly rotate the sensor An O Walk through the coverage N Ball area noting where you are Joint when the lights turn on Move the sensor head up down or sideways to change the cov erage area Keep the sensor at least 1 2 5 cm away Aim Sensor from the lamps Down for Short O Adjust the RANGE as Coverage needed RANGE settoo high may increase false triggering O Secure the sensor head by tightening the clamp screw Do not overtighten the screw Aim Sensor O Setthe amount of ON TIME Higher for Long you want the lights to stay on Coverage after motion is detected 1 5 or 20 minutes O Set the DUAL LIGHT LEVEL switch to the amount of time after dusk you want the lights on at low level Off 3 6 Hrs Dusk to Dawn SPECIFICATIONS Range Up to 70 ft 21 m 100 ft 30 5 m with Range Boost varies with surrounding temperature Sensing Angle Up to 240 Electrical Load Up to 300 Watts Incandescent Maximum Up to 150 Watts Maximum each lamp holder 120 VAC 60 Hz TEST AUTO and MANUAL MODE 1 5 20 minutes Off 3 6 Hours Dusk to Dawn Power Requirements Operating Modes Time Delay Dual Light Level Atlas Lighting Products Inc reserves the right to discon tinue products and to change specifications at any time without incurring any obligation to incorporate new fea tures in produc
7. t of the ball joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp screw when done Wire THE LiGHT CONTROL Turn power off at the fuse or circuit breaker Remove the existing light fixture Install the mounting strap as shown using two screws that fit your junction box O The plastic hanger can be used to hold the fixture while wiring The small end of the plastic hanger can be threaded through the hole in the center of the cover plate The small end then goes into one of the slots on the mounting strap O Route the Light Control s wires through the large gasket holes OU dU as shown Secure with wire connectors Mounting Black to Black White to White Strap Rubber Plug Mounting Bolt Gasket Junction box ground wire to green ground screw on fixture O Twistthe junction box wires and fixture wires together Mount THE LiGHt CONTROL O Align the Light Control cover plate and cover plate gasket Secure with the mounting bolt O Align the three slots in the decorative shell with the lamp holder pins Push the shell in and then twist clockwise to lock Repeat for other shell i k O Push the Rubber Plug firmly into place O Ifawetlocation junction box was not used caulk the wall plate mounting surface with silicone weather sealant To avoid water damage and
8. ts previously sold TROUBLESHOOTING GUIDE If you experience a problem with your Light Control first follow this guide For additional assistance write to Atlas Lighting Products Inc e Customer Service Department P O Box 2348 Burlington NC 27216 SYMPTOM Lights will not POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Light switch is turned off Lights stay on 1 A flood lamp is positioned too close come on Lights come on in daylight Lights come on for no apparent reason Flood light is loose or burned out Fuse is blown or circuit breaker is turned off Daylight turn off is in effect Re check after dark Incorrect circuit wiring if this is a new installation Re aim the sensor to cover de sired area Light Control may be installed in a relatively dark location Light Control is in Test Set control switch to an ON TIME position Light Control may be sensing small animals or automobile traf fic Re aim sensor Range is set too high Reduce Range continuously Lights flash on and off to the sensor or pointed at nearby objects that cause heat to trigger the sensor Reposition the lamp away from the sensor or nearby objects Light Control is pointed toward a heat source like an air vent dryer vent or brightly painted heat reflective surface Reposition sensor Reduce Range Light Control is in Manual Mode Switch to

Download Pdf Manuals

image

Related Search

Related Contents

  Leica IPC et Leica IPS  APOLL APOLLO 3 - Elephant Dental  LONWORKS インタフェースカード LONWORKS Interface Card "OPC  Samsung BX2331  ELN Manual - LabCollector  Camry CR 4110  centrale apricancello keq002a00 2 motori monofase 230vac  À propos de CDJ_Aggregator Création d`un périphérique agrégé  installation instructions & important info  