AMX RDC-DC User's Manual

image

Contents

1. e RESET button By pressing the Reset button located on the RDC DC circuit board it is possible to restart the processor without having to Installation Sheet RDC DC Control Card 120 240 or 277 VAC power down the unit or disconnect AXlink or PROlink Reset does not affect any saved presets or curve settings e MEMORY PROTECT on off jumper The memory protect jumper is set to Off by default To protect saved curve settings and presets from accidental recording put the jumper in the On position Caution Pre Installation Notes e All Class 1 wiring must be connected to proper terminals e All control wiring must be connected to proper terminals e Disconnect power while installing or connecting the unit e Keep top and bottom air bents clear at all times e Test loads for shorts before connecting e Use low voltage wires with a 300 volt rating or greater e Use field installed copper conductors e All electrical ratings are for continuous duty e For indoor use only e AC lighting loads only Connecting RDM Series to the AMX Lighting Master Pin 4 GND Pin 3 RLY Pin 2 DIM o Pin 1 12 V RDC DC 4 pin module connector A 4 pin plug from a RDM series module Note The 4 pin plugs from the module connector to the 4 pin connector on the master black plug cover facing up FIG 2 Connecting RDM series Connectin
2. Vater IT S FOUR WORLD TAKE CONTROL The RDC DC 6 Channel Control Card module controls up to six dimmable channels with six satellite connectors for RDM series dimmer or switching modules The RDC DC is designed for use with the Radia enclosures ina modular digital dimming system It is controlled by AXlink PROlink or by dry contact closures The module s 120 240 and 277 VAC rating is CE UL and C UL approved 8 Mounting points gee 240 VAC Line Input External 12 V power connector optional AXlink DIP switch O Ee PROIink DIP Pe o T switch er REPRE DEES ES MEMORY PROTECT jumper RESET button n AXlink connector Dry closure ase contacts i PROlink connector j l n LED indicators 4d Control Ports i i 1 amm sa a alee im L SA S E e ta C r FIG 1 RDC DC control card RDC DC UL and C UL Ratings Line Input e 120 VAC 2W G 10 50 60 Hz 50 mA e 240 VAC 2W G 10 50 60 Hz 25 mA e 277 VAC 2W G 10 50 60 Hz 22 mA Control Input e AXlink e PROlink e Eight dry closures Control Output e Six control channels e Max total current sourcing 300 mA 12 VDC Specifications e Dimensions HW 10 0 x 2 75 254 0 mm x 69 85 mm e 12 VDC power optional e Torque terminals to 20 in lbs 2 3 N M e Max wire size 10 AWG 4 mm e Wire stripping length 0 28 7 mm e Weight 1 2 Ibs 0 54 kg e Control current 300 mA for six ports Button Jumper Information
3. g AXlink Connect the 4 pin captive wire AXlink from the RDC DC to the Central Con troller for AXlink control of the dimming system pwr optional PWR AXP AXP Central RDC DC AXM AXM Controller GND GND FIG 3 AXlink wiring Connecting PROlink Connect the orange 4 pin captive wire PROlink connector from the RDC DC to a PRO DP8 PROlink wall panel PRO DP8 Pack 1 Pack 2 12 12 PR PR PR PR GND GND FIG 4 PROlink wiring Connecting Dry Closures Use the 8 common dry closures with a WPD8 eight button wall panel 1 2 34 5 6 7 8 COM Each contact 1 8 is pre programmed with a default preset Refer to the AMX Lighting Control System instruction manual for details on dry closure default presets and recording new presets FIG 5 Dry closures connection Each contact closure connection 1 8 is pre programmed with a default preset The table below shows the default presets for each contact closure Dry Closure Default Presets Contact Closure Default Function Channel 1 at 100 in 1 second Channel 2 at 100
4. in 1 second Channel 4 at 100 in 1 second Channel 5 at 100 in 1 second a ae Channel 6 at 100 in 1 second Pack on channels 1 6 Pack off channels 1 6 All other channels are undefined Setting AXlink and PROlink Address Numbers AXlink Address PROlink Address MEE o Test FI Set the AXlink address number Use the PROlink DIP switch to set 1 255 for the RDC DC This the PROlink address number for the number must match the device RDC DC 1 10 number in your Axcess program Pin 8 on the PROlink DIP switch is a test switch that turns all circuits on to full FIG 6 Setting AXlink and PROlink address numbers Lighting Application Drawing Panel Oy yyy OO OY BA All neutrals are common to the Neutral block in the enclosure Provide a separate neutral for each load AMX Corporation reserves the right to alter specifications without notice at any time For full warranty information refer to the AMX Instruction Manual s associated with your Product
5. s 043 019 2242 8 01 2001 AMX Corporation All rights reserved The AMX logo is a trademark of AMX Corporation AMX Corporation reserves the right to alter specifications without notice at any time 3000 research drive richardson TX 75082 USA 469 624 8000 800 222 0193 fax 469 624 7153 technical support 800 932 6993