Home

American Standard Williamsburg 2806E User's Manual

image

Contents

1. Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES Abrasive cleaners must not be used since they will scratch and dull the surface Dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax 752872 100 REV C 4 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE
2. E i L 108mm 51mm 4 1 4 List of Required Tools and Supplies Tools Supplies GENERAL SPECIFICATIONS FOR 2806E WHIRLPOOL e Level e Nails INSTALLED SIZE ___72 x 36 x 21 1 2 In 1829 x 914 x 546mm WEIGHT 135 Lbs 61 Kg e Tape Measure i Putty WEIGHT w WATER 744 Lbs 338 Kg A GAL TO OVERFLOW 73 Gal 276 L g Pipe Wrench 2 Caulking waterproof WHIRLPOOL MIN OPERATING VOL 44 Gal 167 L e Slip Joint Pliers e 1x3or2x2 BATHING WELL AT SUMP 45 x 24 In 1143 x 610mm 3 BATHING WELL AT RIM 60 x 30 In 1524 x 762 mm e Screw Driver Stringers WATER DEPTH TO OVERFLOW 14 1 2 In 368mm FLOOR LOADING 41 Lbs Sq Ft 198 ikgs Sq m e Standard gt Drop Cloth PROJECTED AREA en Woodworking Tools e 20 amp GFI CUBE FT 49 4 e Personal Safety Outlet WHIRLPOOL ELECTRICAL SPECIFICATIONS Equipment e Cement Plaster PUMP 2 1 HP 14 4 AMPS 120V Caulking Gun Grout GENERAL INSTALLATION INFORMATION Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection and during installation protect the bath from construction damage After installation and before enclosing with wallboard tile etc water test the unit and check for leaks Do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void
3. WILLIAMSBURG ELITE 6 HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS 2806E SERIES Amoran Staudard WHIRLPOOL INSTALLATION INSTRUCTIONS a 1829mm ermm Saon 7 THANK YOU 4 ON ORE for selecting an American Standard bath Your new bath is shipped to you after careful inspection The a 229 x 330mm whirlpool version is completely assembled with pump 9 X 13 ae TA _ FLOOR motor and system piping All you need to finish the CUTOUT installation are your selected fittings and electrical connections for a whirlpool 914mm S e FITTING DECK To insure maximum performance and pleasure from this product please follow the instructions and cautions 140mm 5 1 2 I PROVIDE a TO PUMP FOR SERVICE ON ALL INSTALLATIONS AQUTLINE OF va CUTOUT Ril OF DRAIN List of Optional Components not included ONERRLOW e Flex Jet Pulse Jet Kit e Flex Jet Soft Jet Kit G L OF e E Z Install Heater 108mm E LEVELING STRINGER List of Required Components not included e Drain e Bath Filler T hee NOT FOR SUPPORT i L IN LINE HEATER i D REMOVABLE 4 i BLANK m 546mm i 1 1 2 J 495mm DJ 19 172 51m 4 INTEGRAL 2 i FEET N see your Home Depot Retailer SUPPORT ROUGH FLOOR i 1 1 2 N P T M THREADS 7 T 1 1 2 O D TAILPIEC
4. acing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the roughing in drawing for suggested opening size and location dimensions 3 Replace whirlpool and re shim the integral support feet shimming the entire length of the support feet Secure the shims using construction adhesive silicone mortar or equivalent materials VVhile not a necessity the use of a foundation base consisting of cement e g Sakrete mortar or grout will help provide a solid and secure installation TYPICAL PIER TYPE SIMENSIONG INSTALLATION MINIMUM DIMENSION FOR FACE TO FACE OF SUBSTRUCTURE DRAIN END OF WHIRLPOOL i lt 889mm 5 4 Ai a 10mm 3 8 17 3 4 R xX 435mm ie R UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610MM IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED oe SEE CUTOUT TEMPLATE PROVIDED 34 1 4 752872 100 REV C 2 ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electri
5. cian and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be installed on a 120 vac 20 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential ADDING THE E Z INSTALL HEATER REQUIRES A SEPARATE 15 AMP MAXIMUM GFCI CIRCUIT ELECTRICAL INSTALLATION SEPARATE 20 AMP GFCI OUTLET WHIRLPOOL MOUNTED 120 VAC AIR SWITCH OR WALL TIMER ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 752872 100 REV C 3 WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations for copper conductors Rati only Always follow 241 120V Power Line local and national Motor Hi Performance 10 8 electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occured during transit
6. the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others Check for availability of optional American Standard wall tiling bead required for recess installations Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth WARNING Do not lift whirlpool by the piping harness at any time FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS American Standard Inc 2003 All product names listed herein are trademarks of American Standard Inc unless otherwise noted 752872 100 REV C INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown Locate studs as required Ensure roughing in dimensions are proper plumb and square Provisions must be made in all installations for an access opening for servicing the pump and controls It is strongly recommended that an additional opening be provided for access to the drain components NOTE The apron should not be used as the primary access opening 1 Position the whirlpool into the installation opening and level the deck shimming the integral support feet as necessary 2 Install drain components to the whirlpool following the manufacturers instructions Before repl