1. Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE E Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B E Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 andhand tighten Fig A Fig B Fig C STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use ngers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal The Stopper can now be removed by lifting it out of the Drain Fig F _ REMOVE CAM REMOVE CAM CAP M968599 Rev 1 1 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed
2. RISERS MUST BE PURCHASED SEPARATELY Fig B Connect water supply to FAUCET with 1 2 IPS FLEXIBLE SUPPLIES 5 or 3 8 0 D BULL NOSE RISERS 6 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect 1 1 4 O D taifgiece on POP UP DRAIN to waste outlet 2 opens and If STOPPER 2 does not open and close properly then refer 4 D CouUPLING 5 D NUT FLEXIBLE j SUPPLIES 6 3 8 O D BULL NOSE RISERS 1 7 COMPRESSION NUT 3 8 COMPRESSION CONNECTION fA FERRULE G P rs gt M968599 Rev 1 1 1 0 TEST INSTALLED FITTING With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks Remove AERATOR 3 using KEY 3a supplied Operate both HANDLES 1 to ush water lines thoroughly Replace AERATOR 3 CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and Il lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in SINK If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions LUE Release POP UP KNOB 4 down and check all drain connections and P trap for leaks Tign if necessary KO OUTLET 7 SERVICE To change direction of handle Turn valve to OFF position Remove SET SCREW 6 with 5 64 Hex Wrench
3. 0 442 1902 Weekdays 8 00 a m to 6 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST IN MEXICO 01 800 839 12 00 Product names listed herein are trademarks of American Standard Inc AS America Inc 2007 NOT INCLUDED WITH FAUCET A919661 0020A TAILPIECE m M962458 0070A DRAIN MOUNTING KIT M968599 Rev 1 1
4. Installation GREEN TEA Instructions Centerset Lavatory Faucet 7010 201 with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American Standard faucets Speed Connect Drain e Fewer parts installs in less time Never needs adjustment Certi ed to comply with ANSI A112 18 1 e Guaranteed to seal properly the first time every time M968599 Rev 1 1 Your new American Standard faucet is designed to work only with the Speed Connect drain To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools A a RY p B Ab Screwdriver Channel Locks Adjustable Wrench Tubing Cutter INSTALL FAUCET AON cuppice nefore beginning Insert FAUCET 1 and CABLE CONNECTOR 2 FLEXIBLE INLET TUBE 3 and HOSE 4 through mounting holes of Sink or Mounting Surface Fig A Assemble LOCKNUTS 6 onto SHANKS 5 from under side of Sink Hand tighten rmly Fig B HAND TIGHTEN SINK OR MOUNTING SURFACE SA VZV AATA ZYY Vy i Gs 2 3 POP UP DRAIN Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B J a Wig REMOVE FLANGE Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 from drain
5. Pull HANDLE 1 UP rmly to release from ADAPTER 5 64 HEX WRENCH Remove ADAPTER SCREW 3 from ADAPTOR 2 Pull off ADAPTER 2 Remove SPRING CLIP 4 Lift STOP WASHER 5 turn 90 and replace Replace SPRING CLIP 4 Replace ADAPTER 2 and ADAPTER SCREW 3 Find correct position of HANDLE ASSEMBLY 1 by adjusting male teeth on ADAPTER 2 to female teeth in HANDLE ASSEMBLY 1 Push HANDLE 1 down onto ADAPTER 2 Tighten SET SCREW 6 with 5 64 Hex Wrench OPTIONAL SPOUT LOCKING FEATURE The Pull Out SPOUT 1 can be locked to the SPOUT BASE 2 if desired E To secure the Pull Out SPOUT 1 to SPOUT BASE 2 tighten the SET SCREW 3 clockwise in the back of the SPOUT BASE 2 with a 2 5mm hex wrench 2 5mm HEX WRENCH 1 3 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M968599 Rev 1 1 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position Follow CABLE ADJUSTMENT PROCEDURE If Stopper does not raise up fully or sink drains too slowly Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e
6. body Fig A Thread LOCKNUT 3 clockwise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE From under side of SINK install DRAIN BODY 1 up through drain outlet Note No plumber s putty OUTLET or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 rmly FLANGE GASKET AND POP UP KNOB m Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible Fig A m POP UP KNOB 1 must be fully down Fig B NOT VISIBLE Tighten LOCKNUT 1 rmly with Adjustable Wrench or Channel Locks DRAIN paca M968599 Rev 1 1 F ATTACH CABLE CONNECTOR Thread CABLE CONNECTOR onto DRAIN BODY CONNECTION hand tighten Fig A 1 clockwise 2 and Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 O D Fig B CHECK OPERATION OF POP UP Operate LIFT KNOB closes 1 to verify that STOPPER Note to the troubleshooting section of these instructions SPOUT WATER SUPPLY AND WASTE CONNECTIONS Fig A From under mounting surface connnect FLEXIBLE INLET TUBE 1 to HOSEEND 2 and tighten with wrenches Attach WEIGHTS as shown 3 to HOSE 4 at bottom of loop in Hose NOTE FLEXIBLE SUPPLIES OR BULL NOSE
7. or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J LOOP TOWARD REAR OF SINK Re install the Cam Cap making sure the guide teeth are facing outward If the Cam Cap does not snap into place then rotate the Cam to make sure it is fully inserted Fig K DRAIN Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Troubling Shooting Guide to complete installation Stopper will be Locked Mode in Locked mode and not be removable Vandal Proof Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if neces
8. sary to make sure it is fully inserted Fig J Re install the Gam Cap making sure the guide teeth are facing FRONT OF SINK outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Troublingshooting Guide to complete installation Stopper will be Unlocked Mode in Unlocked mode and removable INSTALL CAM CAP M968599 Rev 1 1 GREEN TEA Centerset Lavatory Faucet with Speed Connect Pop Up Drain Americam Standard A953051 0070A CHECK VALVE A912692 0070A 7010 201 M916570 YYYOA HANDLE KIT M922866 0070AA AERATOR MS922372 0070A AERATOR KEY M962624 YYY0A M921371 0070A LIFT ROD amp KNOB ADAPTER Replace the YYY with appropriate nish code CHROME 002 STAINLESS STEEL 075 M918331 0070A A918049 0070A ADAPTER 994053 0070A CARTRIDGE M910840 0070A YZ al M962544 YYYOA PUTTY PLATE STOPPER l ASSEMBLY M952435 0070A CABLE ASSEMBLY A953051 0070A CHECK VALVE M962457 YYYOA M952425 YYYOA FLANGE DRAIN ASSEMBLY ASSEMBLY 065800 0070A ATTACHMENT NUT M922872 0070A CAM SEAT INSERT A M962552 0070A 7 CAM ASSEMBLY M913207 0070A TAILPIECE INSERT M962621 0020A HOSE amp WEIGHT M919660 0020A 6 TAILPIECE HOT LINE FOR HELP For toll free information and answers to your questions call 1 80

Download Pdf Manuals

image

Related Search

Related Contents

Pranchas e Modeladores Dúvidas Possíveis causas  Adesso iMouse S30  Service Manual    Der Einsatz von Weblogs und Wikis im Berufsschulunterricht  CREPE PERSILLEE AUX CHAMPIGNONS En cas hyperprotéiné et  GALEOW  WTi-type Piston Pump Heads User`s Guide  ALK Technologies 11 Laptop User Manual  NGS Jetway  