American Standard ERVR300A9P00A User's Manual

image

Contents

1. Figure 2 Figure 3 Percent Timer P T Control Optional Push Button Control 32 5042 02 Users Information PERCENT TIMER CONTROL PT The Percent Timer Control automatically energizes and de energizes the energy recovery ventilator every hour ensuring ventilation for the home around the clock The PT control has two status lights See Figure 2 Oneis the power light located in the upper left hand corner of the control The other light will be one of the Runtime lights The power light is on whenever the PT control is calling for the ERV torun The Runtime light is located along the right side of the control The Runtime light indicates the amount of time per hour the ERV will operate Set the control per your local code or ASHRAE Std 62 2 and your ventilator will run once every hour FOR CONSTANT OPERATION Press the fan icon until the 100 light is on The Runtime light turns on The ERV unit will run continuously FOR MINIMUM VENTILATION REQUIREMENT OPERATION Set the control at the percentage that meets local code or ASHRAE 62 2 Press the fan icon until the light for the percent desired is on TO TURN THE ERV OFF Press the fan icon until all lights are off The control is off The ERV motor is de energized Power is still persent inside the unit Always unplug cord from outlet before servicing GENERAL SETTINGS For systems installed in an area with high humidity The Percent Timer should be set to deliver
2. because of a manufacturing defect within one year from the date of original purchase Warrantor will furnish the required replacement part Any local transportation related service labor diagnosis calls refrigerant and related items are not included THIS LIMITED WARRANTY IS IN LIEU OF ANY EXPRESS WRITTEN LIMITED WARRANTY ACCOMPANYING ANY OF THE ABOVE INDOOR PRODUCTS If the heat transfer core should become defective because of a manufacturing defect within ten years from the date of original purchase Warrantor will furnish without charge the required replacement heat transfer core Any local transportation related service labor diagnosis calls and related items are not included This limited warranty does not cover failure of your ERV if it is damaged while in your possession damage caused by acts of God damage from unreasonable use of the ERV and or damage from failure to properly maintain the ERV as set forth in the Users Information Guide THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES WHETHER IN CONTRACT OR IN NEGLIGENCE EXPRESS OR IMPLIED IN LAW OR IN FACT INCLUDING BUT NOT SPECIFICALLY LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE AND IN NO EVENT SHALL WARRANTOR BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow limitations on how long an implied limited warranty lasts or do not allow the exclusion or limitation
3. MACAU A 32 5042 02 Energy Recovery Ventilator ERV E RVR 100A9P 00A E RVR 200A9P00A E RVR300A9P00A May be A or T 32 5042 02 Users Information GENERAL INFORMATION Understand the signal words WARNING AND CAUTION These words are safety alert words WARNING indicates hazards which could result in personal injury or death CAUTION is used to indicate unsafe practices which could result in minor injury or property damage A WARNING Disconnect Power Before Servicing Failure to follow the electrical servicing instruction may cause Personal Injury or Death A WARNING Do Not Use This Unit if Any Part Has Been Under Water Immediately Call A Qualified Service Technician To Inspect The ERV and To Replace Any Part of The Control System Which Has Been Under Water A CAUTION PERSONAL INJ URY HAZZARD Failure to follow filter service instructions may cause personal injury The access door swings down when unit is installed overhead Carefully hold the access door while unlatching and lowering The door should be removed prior to performing filter service FILTER SERVICE A Clean Filter Saves Money When the ERV provides fresh outdoor air into your home and exhausts indoor air to the outside dust and dirt particles build up on the air filters Excessive accumulation can block airflow decreasing the ERV s performance and increase energy usage To maintain top performance be sure to clean or replac
4. PANYING ANY OF THE ABOVE INDOOR PRODUCTS If the heat transfer core should become defective because of a manufacturing defect within ten years from the date of original purchase Warrantor will furnish without charge the required replacement heat transfer core Any local transportation related service labor diagnosis calls and related items are not included This limited warranty does not cover failure of your ERV if it is damaged while in your possession damage caused by acts of God damage from unreasonable use of the ERV and or damage from failure to properly maintain the ERV as set forth in the Users Information Guide THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES WHETHER IN CONTRACT OR IN NEGLIGENCE EXPRESS OR IMPLIED IN LAW OR IN FACT INCLUDING BUT NOT SPECIFICALLY LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE AND IN NO EVENT SHALL WARRANTOR BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow limitations on how long an implied limited warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state Parts will be provided by our factory organization through an authorized service organization in your area lis
5. e the ERV filters according to the instructions in this manual Clean filters every three months when the unit is in regular use or as needed to keep them clean How toremove and clean your filter 1 Release cam latches and carefully swing access door open The access door may be removed for ease of service by sliding the access door off Use caution when removing door 2 Remove the filter retainer springs Pull the filters out See Figure 1 3 Vacuum filters off with a hose attachment 4 Reinstall filters and retainer spring 5 Reinstall cover and fasten cam latches 2 FILTER SERVICE NOTES A The filters should be replaced after they have been cleaned several times Contact your installing dealer for service and replacement filters Replacement filter model numbers are as follows Model Filter ERVR100 BAYFLT10A1010A ERVR200 BAYFLT20A1020A ERVR300 BAYFLT20A1020A B Filters may be cut from a sheet or roll of 34 1 firm spun polyester filter hog hair media or material similar to the existing factory installed green blue filter in the unit The size of each filter 2 required per unit is listed as follows ERVR100 ERVR200 300 10 x10 10 x217 4 First letter of model number may be an A or T C Filters must always be used during unit operation or the heat transfer core will become blocked by particulate matter The filters supplied in the unit are typically abl
6. e to keep the heat transfer core clear for many months Finer filters may be used but must be cleaned more often HEAT TRANSFER CORE SERVICE The Heat Transfer Core may also be referred to as the Energy Exchange Element or Heat Exchanger Vacuum the Face of the Heat Transfer Core Yearly Particulate matter collects only on the entering faces of the heat transfer core The interior of the heat transfer core stays clean even if the element faces are covered particulates TO CLEAN THE HEAT TRANSFER CORE 1 Remove filter retainer spring and the filters see above 2 Vacuum the exposed faces of the heat transfer core with a soft brush attachment 3 After servicing the filters reinstall them and the filter retainer spring see above 4 Vacuum out dust from the rest of the unit case A CAUTION DO NOT WASH THE HEAT TRANSFER CORE Always handle the core carefully Keep it away from water or fire to avoid damaging it The heat transfer core can be replaced but is expensive 32 5042 02 Users Information Heat Transfer Core Filter Retainer Figure 1 Energy Recovery Ventilator with cover removed Power Light Runtime Lights Press Fan icon on touchpad one or more times to obtain desired Runtime Press once for 20 minutes twice for 40 minutes three times for 60 minutes Press the Fan icon for 5 seconds to cancel Press Fan icon on touchpad one or more times to obtain desired Runtime
7. ecovery ventilator for a short period of operation for example when you are using a bathroom The PB Control must be connected to a PT control to operate 20 40 60 minute ventilation control Press the fan icon and your ventilator will run for 20 minutes See Figure 3 Press again and the unit will run 40 minutes A third press provides for 60 minutes of operation Percent Timer Control does not need to be on for the PB Control to operate the ERV unit You can cancel a cycleat anytime J ust press the fan icon and hold for about five seconds You can start another cyde by pressing the fan icon NOTE for ERV systems with more than one control Another control other than the push button may be causing your ventilator to run If you wish to keep your ventilator from running check that none of your controls are calling for unit operation Installation 4 Install control in a standard 2 x 4 electrical box with a minimum depth of 1 5 with the two screws provided 5 Wire Size 18 gauge no more than 500 feet Wiring is non polar 6 Two wires from the PB Control should be attached to the PB positions on the terminal block on the back of the Percent Timer Control 7 For twoPB controls one wire from each can be twisted together and inserted into a single position on the terminal block on the Percent Timer Control The wires must be a 18 gage solid wire If more than two PB controls are attached or 18 gage stranded w
8. ire is used then pigtails must be inserted into the PB positions on the Percent Timer Control and the leads attached to the pigtails with wire nuts 8 UseLutron Decora cover plate to complete installation 32 5042 02 Users Information Limited Warranty Energy Recovery Ventilator ERV ERVR100 200 300 Parts Only Models for Residential Use This limited warranty is extended by American Standard Inc to the original purchaser and to any succeeding owner of the real property to which the ERV is originally affixed and applies to products purchased and retained for use within the U S A and Canada only If any internal functional part of your ERV fails because of a manufacturing defect within five years from the date of the original purchase Warrantor will furnish without charge the required replacement part Any local transportation related service labor diagnosis calls and related items are not included If compatible ERV controls are incorporated in the HVAC system and are installed at the same time as your ERV then if any Warrantor furnished internal functional part of the ERV controls fail because of a manufacturing defect within five years from the date of original purchase Warrantor will furnish the required replacement part Any local transportation related service labor diagnosis calls refrigerant and related items are not included THIS LIMITED WARRANTY IS IN LIEU OF ANY EXPRESS WRITTEN LIMITED WARRANTY ACCOM
9. of incidental or consequential damages so the above limitation or exclusion may not apply to you This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state Parts will be provided by our factory organization through an authorized service organization in your area listed in the yellow pages If you wish further help or information concerning this limited warranty contact American Standard Inc 6200 Troup Highway Tyler TX 75707 Attention Manager Field Operations Excellence GW 659 0106 This limited warranty is for commercial usage of this equipment and not applicable when this equipment is used for a residential application A commercial use is any application where the end purchaser uses the product for other than personal family or household purposes American Standard Inc 6200 Troup Highway Tyler 1X 75707 MMMM For more information contact Since the manufacturer has a policy of continuous product and product data improvement it reserves the right to your local dealer distributor change design and specifications without notice
10. ted in the yellow pages If you wish further help or information concerning this limited warranty contact American Standard Inc 6200 Troup Highway Tyler TX 75707 Attention Manager Field Operations Excellence GW 658 0106 This limited warranty is for residential usage of this equipment and not applicable when this equipment is used for a commercial application A commercial use is any application where the end purchaser uses the product for other than personal family or household purposes 32 5042 02 5 Limited Warranty Energy Recovery Ventilator ERV ERVR100 200 300 Parts Only Models for Commercial Use This limited warranty is extended by American Standard Inc to the original purchaser and to any succeeding owner of the real property to which the ERV is originally affixed and applies to products purchased and retained for use within the U S A and Canada only There is no warranty against corrosion erosion or deterioration If any internal functional part of your ERV fails because of a manufacturing defect within one year from the date of the original purchase Warrantor will furnish without charge the required replacement part Any local transportation related service labor diagnosis calls and related items are not included If compatible ERV controls are incorporated in the HVAC system and are installed at the same time as your ERV then if any Warrantor furnished internal functional part of the ERV controls fail
11. the Minimum Ventilation Requirements VACATION SETTINGS For systems installed in an area with high humidity f the A C system thermostat setting is elevated or set up while on vacation or for extended periods of time over 2 days the Percent Timer and ERV should be turned OFF After returning from vacation or when the system thermostat is lowered to normal daily setting the Percent Timer and ERV should be reset to the previous runtime WHEN WINDOWS ARE OPEN When windows are open in your home the Percent Timer and ERV should be turned OFF NOTE for ERV systems with more than one control Another control may be causing your ventilator to run even if the runtime light on this control is off If you wish to keep your ventilator from running check that none of your controls are calling for unit operation Installation 1 Install control in a standard 2 x 4 electrical box with a minimum depth of 1 5 with the two screws provided 2 Wire Size 18 gauge no more than 500 feet Wiring is non polar 3 Thetwowires fromthe ERV should be attached to the C and R positions on the terminal block on the back of the PT Control See Figure 13 4 UseLutron Decora cover plate to complete the installa tion supplied by installer PUSH BUTTON POINT OF USE CONTROL OPTIONAL ACCESSORY For use with all ERV models Operation The Push Button PB Point of use Control lets you manually turn on your energy r

Download Pdf Manuals

image

Related Search

Related Contents

LifeSize Room 220 Installationshandbuch 4.5  Seleziona e stampa pagina  TP-LINK TL-WN823N  Notification de la préfecture  los proyectos hacen los objetos eternos, las modas los  • Brugervejledning • Gebrauchsanleitung • Instructions for - OX-ON  the User Manual  VIDEOMIC PRO  smoothing shampo .  general conditions - Long Island School Nutrition Directors Association  