Allied Telesis AT-MC602 User's Manual
Contents
1. LINK Green A link has been established on the port ACT Green Data is being received on the ports LINE Port ERR Green An error has been detected on the port LINK Green A link has been established on the port AT MC601 and AT MC602 Installation and User s Guide MGMT Port The management port features a 8 pin DIN connector for connecting the network extenders to your laptop or PC compatible computer for configuration using the provided management cable Management The management cable included with the AT MC602 Provider unit Cable features a 9 pin RS 232 connector to attach to your computer and an 8 pin DIN connector to attach to the network extender Figure 5 Management Cable Table 5 lists the management cable connector pins and their signals Table 5 Management Cable Pinouts RS 232 Pin DIN Pin Signal 1 1 Not Used 2 2 TXD 3 8 RXD 4 5 DSR 5 6 GND 6 3 DTR 7 4 CTS 8 7 RTS 9 N A Not Used AT MC601 and AT MC602 Installation and User s Guide AC Power Supply Input Port External AC DC Power Adapter The network extender has a single DC power supply socket on the back panel The unit does not have a power switch To turn the network extender ON or OFF you connect or disconnect the power cord An external AC DC power adapter is included with the network extender for desktop or wall mount operation The power adapter supplies 12V DC to t
2. Simply switch the management cable to the other unit to correct the problem A Can t read link status This message occurs when the software cannot read the link status from the Provider side Perform the procedure described in Configuring the Subscriber Unit on page 45 to see if link recovery on the Subscriber unit solves the problem Q Please run this program on S side to set it in Install mode If S side is already in install mode then configuration can not be achieved as shown in Figure 29 AT MC60XCONF Please run this program on S side to set it in Install mode If S side is already in install mode then configuration can not be achieved Figure 29 Run on S Side Error Message 49 a AT MC601 and AT MC602 Installation and User s Guide This error message occurs when the Provider unit cannot achieve the link with the S or Subscriber side unit using the default speeds value Set the Subscriber to Install Mode as described in Configuring the Subscriber Unit on page 45 Configuration file was not found u Syntax error in configuration file u Configuration cannot be achieved These last three error messages indicate a problem with the configuration software Try re loading the software onto your computer 50 Appendix A Default Configuration Settings This appendix lists the AT MC601 and AT MC602 default settings Setti
3. Utiliser un adaptateur secteur conforme T V de 12 V dc 500 mA en courant continu amp 5 A Attention Le cordon d alimentation sert de mise hors circuit Pour couper l alimentation du mat riel d brancher le cordon ES 6 Danger De Foudre gt Danger NE PAS MANIER le mat riel ou les CABLES lors d activit orageuse 17 A Ne pas bloquer les fentes d a ration 68 N Ne pas connecter une ligne t l phonique au connecteur de signaux amp 9 Temp rature De Fonctionnement Ce mat riel est capable de tol rer une temp rature ambiante maximum de 40 degr s Celsius 64 10 Pour Tous Pays Installer le mat riel conform ment aux normes lectriques nationales et locales 59 AT MC601 and AT MC602 Installation and User s Guide Standardit T m tuote on seuraavien standardien mukainen 1 Radioaaltojen h irint EN55022 Luokka A FCC Part 15 Luokka A C TICK Gs 2 Kest vyys EN55024 G 3 S hk turvallisuus EN60950 UL60950 FCC Part 68 Turvallisuus G 4 A Tahtipisteeseen hub sy tett v n virran pit tulla ainoastaan sovittimesta Europe EC K yt TUV lisenssill valmistettua verkkosovitinta jonka tasaj nnitteen nimellisarvot ovat 12 Vdc 500 mA milliampeeria amp 5 N Huomautus Virtajohtoa k ytet n virrankatkaisulaitteena Virta katkaistaan irrottamalla virtajohto amp 6 Salamaniskuvaara Hengenvaara AL TYOSKENTELE laitteiden tai KAAPELEIDEN KANSSA SALAMOINNIN AIKANA arn N Ala tuki ilma
4. www alliedtelesyn com To find the contact information for your country select Contact Us then Worldwide Contacts New releases of management software for our managed products can be downloaded from either of the following Internet sites Allied Telesyn web site http www alliedtelesyn com Allied Telesyn FTP server ftp ftp alliedtelesyn com If you would prefer to download new software from the Allied Telesyn FTP server from your workstation s command prompt you will need FTP client software and you will be asked to log in to the server Enter anonymous as the user name and your email address for the password Chapter 1 Product Description The AT MC601 AT MC602 Extended Ethernet products are designed to transmit data at very high speeds over unshielded pairs of copper wires using VDSL technology on your existing telephone line Summary of Features VDSL Very high bit rate Digital Subscriber Line port PSTN Public Switched Telephone Network port 10 100 Mbps Ethernet port with an RJ 45 connector Auto MDI MDI X D D D D O Auto Negotiation for speed and duplex mode IEEE 803 3u compliant Status LEDs Management port AT S57 configuration software D D D O 12V DC external power supply input port Overview AT MC601 and AT MC602 Installation and User s Guide These devices can be used in multi dwelling units MDU multi tenant buildings MTU and in the hospitality industry such as airports hotels
5. The AT S57 configuration software is included on the Documentation CD provided with the units New releases of the AT S57 configuration software are available from the Allied Telesyn Web site at www alliedtelesyn com or from our FTP server at ftp alliedtelesyn com To log on to the FTP server enter anonymous for the user name and your email address for the password Management software for the AT MC601 and AT MC602 VDSL network extenders will have S57 as part of the file name Once you have a copy of the software on your computer connect the Provider unit to your computer using the management cable provided as shown in Figure 18 Attach the 9 pin RS 232 end of the cable to the COM 1 or COM 2 port on your computer Attach the 8 pin DIN end of the cable to the management port on the unit Figure 18 Connecting the Management Cable If the network extender is not already on power on the unit using the power cable provided Refer to Powering On the Subscriber Unit on page 29 for further instructions on how to power on the unit 36 AT MC601 and AT MC602 Installation and User s Guide Opening the Open the configuration software by double clicking the ATS57 Configuration application icon as you would with any other software program The AT Software MC60x Configurator pop up will appear as shown in Figure 19 AT MC60x Configurator x Select Serial Port comi About Figure 19 AT MC60x Configurator If you w
6. and set the rates by clicking the Apply button Then reports on the status of the attempt to configure the speeds selected from the upstream and downstream pull down menus will appear in this field A successful configuration attempt will cycle though the following status reports Looking for link status Checking signal noise ratio Loading a Configuration DS 1 41 US 2 81 This report will keep repeating with progressively higher upstream and downstream values until the set rate or the highest possible rate has been achieved Saving config on EEPROM S Side Saving config on EEPROM P Side Done 39 VDSL Status AT MC601 and AT MC602 Installation and User s Guide The Configuration Saved pop up shown in Figure 22 will appear when the set rate or the highest possible rate has been achieved AT MC60xConf Configuration saved Figure 22 Configuration Saved An unsuccessful configuration attempt may include the following status reports Loading defaults Can t read link status Done These negative status reports may also be accompanied by error message pop ups Error messages are explained in Troubleshooting on page 47 HIGH gt LOW LOW gt HIGH Allows you to choose the negotiation direction for the modem speed The default and preferred direction is Low gt High Choosing a negotiation direction determines how the modem searches for speeds When set to Low gt High the modem will start at minimum speeds an
7. components are included in your network extender package If any item is missing or damaged contact your Allied Telesyn sales representative for assistance A One AT MC601 or AT MC602 Network Extender Four protective feet Two Phillips head screws for wall mounting Two plastic anchors for wall mounting One power adapter One management cable provided for AT MC602 model only Documentation and configuration software CD EC De EE E Warranty and registration card 25 AT MC601 and AT MC602 Installation and User s Guide Installing the AT MC601 Subscriber Unit The AT MC601 Subscriber unit will most likely be used as a stand alone device or can be used as a desktop device or mounted onto a wall using the keyholes on the bottom of the unit The screws and plastic anchors used for mounting the unit are provided Using the To use the Subscriber unit on a desktop perform the following Subscriber Unit procedure on a Desktop 1 Remove all equipment from the package and store the packaging material in a safe place 2 Attach the four protective feet provided to each corner of the bottom of the unit as illustrated in Figure 6 13NY3H13 O30ON31X3 ISIA L 09OIN 1V LLL212 PIV WW NT Figure 6 Attaching Protective Feet to the Subscriber Unit 26 AT MC601 and AT MC602 Installation and User s Guide Wall Mounting The Subscriber unit can be mounted onto a wall using the keyholes on
8. A FCC Part 15 Class A C TICK Immunity EN55024 Electrical Safety EN60950 UL60950 FCC Part 68 Safety Power to the hub must be sourced only from the adapter Europe EC Use T V licensed AC adapter of 12 V DC min 500 mA Other Countries Use a Safety Agency Approved AC adapter of 12 V DC min 500 mA Caution Power cord is used as a disconnection device To de energize equipment disconnect the power cord Lightning Danger Danger Do not work on equipment or cables during periods of lightning activity Do not block air vents Do not connect a telephone line into the signal connector Operating Temperature This product is designed for a maximum ambient temperature of 40 degrees C All Countries Install product in accordance with local and National Electrical Codes 55 AT MC601 and AT MC602 Installation and User s Guide Normen Dieses Produkt erf llt die Anforderungen der nachfolgenden Normen 6 1 Hochfrequenzst rung EN55022 Klasse A FCC Part 15 Klasse A C TICK 2 St rsicherheit EN55024 3 Elektrische Sicherheit EN60950 UL60950 FCC Part 68 Sicherheit G 4 N Der Buchse darf nur aus dem Adpater Strom zugef hrt werden Europe EC Gebrauchen Sie einen von T V zugelassenen Wechselstromadapter f r Gleichstrom 12 Vdc 500 mA 5 N Vorsicht Das netzkabel dient zum trennen der stromversorgung Zur trennung vom netz kabel aus der steckdose ziehen 6 Gefahr Durch Blitzschlag Gefahr Keine Arbeiten am Ger t od
9. Ds LEDs PWR Wu PSTN AVA Allied Telesyn AT MC601 vbsL EXTENDED ETHERNET Management Port VDSL Line Port Ethernet Port PSTN Port Ethernet Status LEDs ED Ede VDSL Line LINK LEDs AME Nied Telesyn MC602 vos SEE ETHERNET Figure 2 Front Panels Figure 3 illustrates the rear panel of the AT MC601 and AT MC602 network extenders DC Power Supply Port M4 Self Clinching Nut Figure 3 Rear Panel AT MC601 and AT MC602 Installation and User s Guide Hardware Features The following sections describe these hardware features of the AT MC601 and AT MC602 network extenders Q VDSL Line port Q PSTN port 10 100 Mbps twisted pair Ethernet port Status LEDs Management port Management cable 12V DC power supply input port D D D D O D External AC DC power adapter Note The AT MC602 unit can only be installed in an AT MCR12 chassis VDSL Line Port The VDSL Line port allows you to connect the AT MC601 Subscriber unit to a telephone jack wall outlet and the AT MC602 Provider unit to the inside phone line at the wiring closet The two units need to be within 1 200 meters of each other in order for the port to operate properly The port transmits voice data at a frequency of 8 10 KHz and Ethernet data at frequencies of 300 KHz to 8 MHz This port features an RJ 11 connector Table 1 lists the RJ 11 port pinouts and their ass
10. Extended Ethernet AT MC601 AT MC602 Installation and User s Guide AN Allied Telesyn Simply connecting the world Copyright O 2004 Allied Telesyn Inc www alliedtelesyn com All rights reserved No part of this publication may be reproduced without prior written permission from Allied Telesyn Inc Microsoft is a registered trademark of Microsoft Corporation Netscape Navigator is a registered trademark of Netscape Communications Corporation All other product names company names logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners Allied Telesyn Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn Inc be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein even if Allied Telesyn Inc has been advised of known or should have known the possibility of such damages Electrical Safety and Emission Statement Standards This product meets the following standards U S Federal Communications Commission Declaration Of Conformity Manufacture Name Allied Telesyn Inc www alliedtelesyn com Declares that the product Exten
11. and convention centers These units are sold in pairs with the AT MC601 functioning as the subscriber and the AT MC602 functioning as the provider In an MDU such as a university dormitory the subscriber unit would be installed in each room and connected to a provider unit through the telephone outlet Each AT MC602 or provider unit would be located in the building wiring closet The AT MC601 Extended Ethernet unit can be used as a desktop or wallmount device while the AT MC602 unit must be installed in an AT MCR12 rackmount chassis Refer to Installing the AT MC602 Provider Unit on page 30 for installation details These units are easy to install They can be configured and managed through the MGMT port using the software provided on the installation CD When both the AT MC601 Subscriber and the AT MC602 Provider have been installed the network extender system topology shown in Figure 1 is complete Computer s IT J Telephone Ethernet Port a AT MC601 Subscriber zul EN an VDSL Line through wall interior phone line AT MC602 EB am Provider L Unit LA Internet Service Leleo PBX Provider Y Line Figure 1 Network Extender System Topology AT MC601 and AT MC602 Installation and User s Guide Location of Components Figure 2 illustrates the front panels of the AT MC601 and AT MC602 network extenders Ethernet osse gue E VDSL Line Status ACT EG LE
12. d keeps negotiating progressively higher speeds until it has achieved its maximum speed for the connection Apply Press the Apply button to set your data transfer rates and negotiation direction selections About Use the About button to display the version number of the AT S57 configuration software To view the VDSL Status screen click on the VDSL Status tab at the top of the menu 40 AT MC601 and AT MC602 Installation and User s Guide The VDSL Status screen is displayed in Figure 23 AT MC60x Configurator link DOWN er Le Pr riene me SS F 1 Figure 23 VDSL Status The parameters on the VDSL Status screen are described below These parameters are for viewing and monitoring purposes only They cannot be changed manually SNR of Received Signal The Signal to Noise Ratio on the VDSL line measured in decibels The SNR is a parameter of the constellation of the receive signal Corrected RS errors s Number of corrected Reed Solomon errors per second Mean Sguare Error An indication of the symbol error rate measured in decibels Full Constellation Link The highest possible OAM Quadrature Amplitude Modulation constellation which enables the highest line rates 41 Ethernet Status AT MC601 and AT MC602 Installation and User s Guide Reduced Constellation Link A lesser QAM constellation causing reduced line rates If the full constellation rate cannot be achieved because the received SNR is too l
13. d twisted pair cabling is recommended Auto MDI MDI X An RJ 45 twisted pair port on a 10 100 Mbps Ethernet network device can have one of two possible wiring configurations MDI or MDI X The RJ 45 port on a PC router or bridge is typically wired as MDI while the twisted pair port on a switch or hub is usually MDI X The AT MC601 and AT MC602 network extenders feature automatic MDI MDI X Each port automatically determines the configuration of the port on the device to which it is connected and then configures itself appropriately For example if a port on a network extender is connected to a port on a bridge which is typically wired as MDI the port on the network extender automatically configures itself as MDI X This feature allows you to use either straight through or crossover cables when connecting devices to the network extender AT MC601 and AT MC602 Installation and User s Guide Auto Negotiation The network extenders Auto Negotiate the speed and duplex mode of the Ethernet link so that the link comes up in the highest performance configuration supported by both ends Half and Full duplex Mode Duplex mode refers to the way an end node sends and receives data on the network An end node can operate in either half or full duplex mode depending on its capabilities An end node that is operating in half duplex mode can either send data or receive data but it cannot do both at the same time An end node that is operating in full d
14. ded Ethernet Model Numbers AT MC601 AT MC602 This product complies with FCC Part 15B Class A Limits This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device must not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Radiated Energy Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with instructions may cause harmful interference to radio or television reception which can be determined by turning the equipment off and on The user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connectthe equipment into an outlet on a circuit different from that to which the receiver is connected Consultthe dealer or an experienced radio TV technician for help Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Commu
15. djust and monitor the operating parameters of the media converter Some of the functions that you can perform with the software include A Determine the VDSL link status Q Set the upstream and downstream data transfer rates A Monitor the status of the VDSL parameters on both the local and remote units A Monitor the status of the Ethernet parameters on both the local and remote units A Link recovery The AT S57 configuration software is included on the Documentation CD included with the network extender The default settings may be adequate for some networks and may not need to be changed If this is true for your network then you can use the network extenders by simply connecting the units to your network as explained in Installation on page 20 Note The default settings for the configuration software can be found in Appendix A on page 51 To actively configure a network extender by changing or adjusting its operating parameters you must access the AT S57 software while connected to the AT MC602 Provider unit The AT S57 software has a menu interface that makes it very easy to use 35 AT MC601 and AT MC602 Installation and User s Guide Starting a Configuration Session Downloading Software Updates Cabling Preparations In order to configure and manage your AT MC601 and AT MC602 VDSL network extenders you need to download a copy of the configuration software onto the computers you will use to manage the units
16. e speed The default configuration parameters start at 0 94 Mbps upstream and downstream with negotiation set from Low High Select the option that corresponds to your mode choice and click the Apply button When the mode has been set the AT MC60x Configurator Done message will appear as displayed in Figure 26 AT MC60XCONF Done Figure 26 Done Message When you have finished setting the mode on the Subscriber unit click the Close button on the bottom right of the AT MC60x Configurator menu to exit from the configuration software 46 Chapter 4 Troubleshooting This chapter contains information on how to troubleshoot the AT MC601 and AT MC602 network extenders in the event a problem occurs Note If after following the instructions in this chapter you are unable to resolve the problem contact Allied Telesyn Technical Support for assistance Refer to Contacting Allied Telesyn Technical Support on page 9 for information on how to contact our Technical Support Department LEDs Check the PWR LED on the front of the network extender If the LED is OFF indicating that the network extender is not receiving power do the following a Ifthe network extender is inserted in the AT MCR12 chassis make sure that the power cord is securely connected to the power source and to the power connector on the back panel of the AT MCR12 chassis If the network extender stands alone make sure that the provided adapt
17. ecautions Please review the following safety precautions before you begin to install the network extenders Refer to Translated Electrical Safety and Emission Information on page 54 for translated safety statements in your language Caution Power to the hub must be sourced only from the adapter amp 4 Europe EC Use TUV licensed AC adapter of 12 V DC min 500 mA Other Countries Use a Safety Agency Approved AC adapter of 12 V DC min 500 mA Caution Power cord is used as a disconnection device To de energize equipment disconnect the power cord amp 5 Warning Lightning Danger Do not work on this equipment or cables during periods of lightning activity amp 6 Caution Air vents The air vents must not be blocked on the unit and must have free access to the room s ambient air for cooling 47 7 Caution Operating Temperature This product is designed for a maximum ambient temperature of 40 C amp 9 Caution All Countries Install this product in accordance with local and national electric codes amp 10 21 AT MC601 and AT MC602 Installation and User s Guide Additional Additional telecommunication related compliance warning statements Compliance Used with the AT MC601 and AT MC602 Extended Ethernet units are Warning listed below Statements Warning When using your telephone equipment basic safety precautions should always be followed to reduce the risk of fire electronic shock and injury to persons
18. ector de sefiales 9 Temperatura Requerida Para La Operaci n Este producto est disefiado para una temperatura ambiental m xima de 40 grados C amp 10 A Para Todos Los Pa ses Monte el producto de acuerdo con los C digos El ctricos locales y nacionales 64 AT MC601 and AT MC602 Installation and User s Guide Standarder Denna produkt uppfyller f ljande standarder s 1 Radiost rning EN55022 Klass A FCC Part 15 Klass A C TICK Gs 2 Immunitet EN55024 6 3 Els kerhet EN60950 UL60950 FCC Part 68 S kerhet GS 4 N Endast anslutningsenheten far vara kraftk lla till centralen Europe EC Anv nd en v xelstr msanslutningsenhet licensierad av T V Likstr m 12 Vdc 500 mA 5 Varning N tkabeln anv nds som str mbrytare f r att koppla fr n str mmen dra ur n tkabeln e 6 Fara F r Blixtnedslag A Fara ARBETA EJ p utrustningen eller kablarna vid ASKVADER e N Blockera inte luftventilerna 68 A Koppla inte telefonledning till signalkontakten EL 9 Driftstemperatur Denna produkt r konstruerad f r rumstemperatur ej verstigande 40 grader Celsius amp 10 N Alla L nder Installera produkten i enlighet med lokala och statliga best mmelser f r elektrisk utrustning 65
19. eee bae tete ele de ete edidere eee de pec AS deg 52 Physical Specifications a Environmental Sp cifications mii ARA 52 Power Sp cifications ect e RR RR RR Sd hees elment aeta 52 Safety and Electromagnetic Compatibility Certifications EEN 53 Appendix C Translated Electrical Safety and Emission Information EEN 54 Preface How This Guide This guide contains instructions on how to install and configure the AT MC601 and AT MC602 Extended Ethernet units is Organized This manual contains the following chapters and appendices Chapter 1 Product Description describes the features and components of the network extenders Chapter 2 Installation contains installation instructions for each unit Chapter 3 Configuration explains how to use the configuration software The AT S57 software is used to configure the network extenders Chapter 4 Troubleshooting provides information on how to resolve common problems that might occur with the network extenders Appendix A Default Settings lists the default software settings Appendix B Technical Specifications lists the technical specifications for the network extenders Appendix C Translated Electrical Safety and Emission Information contains multi language translations of the warnings and cautions in the manual AT MC601 and AT MC602 Installation and User s Guide Document Conventions This document uses the following conventions Note Notes provide additional info
20. er an den Kabeln w hrend eines Gewitters ausf hren ss 7 N Entl ftungs ffnungen nicht versperren 68 N Verbinden Sie nicht das Telefonkabel mit dem Signalverbindungsstecker 6 9 A Betriebstemperatur Dieses Produkt wurde fir den Betrieb in einer Umgebungstemperatur von nicht mehr als 40 C entworfen amp 10 Alle Lander Installation muf rtlichen und nationalen elektrischen Vorschriften entsprechen 56 AT MC601 and AT MC602 Installation and User s Guide Standarder Dette produkt tilfredsstiller de f lgende standarder s 1 Radiofrekvens forstyrrelsesemission EN55022 Klasse A FCC Part 15 Klasse A C TICK Gs 2 Immunitet EN55024 G 3 Elektrisk sikkerhed EN60950 UL60950 FCC Part 68 Sikkerhed S 4 N Str mforsyningen til apparatet m udelukkende tages fra tilpasningstransformatoren Europe EC Brug kun T V godkendt vekselstr mstransformator p 12 Vdc 500 mA 5 Advarsel Den str mf rende ledning bruges til at afbryde str mmen Skal str mmen til apparatet afbrydes tages ledningen ud af stikket ES 6 Fare Under Uvejr Fare UNDLAD at arbejde p udstyr eller KABLER i perioder med LYNAKTIVITET e N Ventilations bningerne m ikke blokeres SS 8 A Tilslut ikke telefonledninger til signalstikforbindelsen 9 Betjeningstemperatur Dette apparat er konstrueret til en omgivende temperatur p maksimum 40 grader C G 10 N Alle Lande Installation af produktet skal ske i overensstemmelse med lokal og nationa
21. er is securely connected to the power source and to the power connector on the back panel of the network extender Verify that the power outlet has power by connecting another device to it Q Try connecting the network extender to another power source A Try using a different power cord or a different power adapter A Check that the voltage from the power source is within the required levels for your region 47 AT MC601 and AT MC602 Installation and User s Guide Verify that the ACT LED for each twisted pair port is ON If a ACT LED is OFF do the following Q Verify that the end node connected to the port is powered ON and is operating properly Q Check that the twisted pair cable is securely connected to the port on the network extender and to the port on the end node Q Make sure that the twisted pair cable does not exceed 100 meters 328 feet Q Verify that you are using the appropriate category of twisted pair cable Category 3 or better for 10 Mbps operation Category 5 and Category 5E for 100 Mbps operation Q Make sure that the operating parameters of the port on the network extender are compatible with the end node to which the port is connected Error Messages When using the configuration software you may encounter the following error messages Q No answer from device as shown in Figure 27 AT MC60XCONF No answer from device Figure 27 No Answer Error Message This error message may occur when
22. gainst harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note Modifications or changes not expressly approved of by the manufacturer or the FCC can void your right to operate this equipment This equipment complies with Part 68 if the FCC rules and the requirements adopted by the ACTA On the bottom of the equipment is a label that contains among other information a product identifier in the following format US ASTOTOOBMC60X If requested this number must be provided to the telephone company FCC Part 68 Product Identifier This equipment complies with Industry Canada CS03 Standard Certificate Number IC 336A MC60X This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Industry Canada amp 1 amp 2 amp 3 4 gt 5 or 6 ss 7 6 8 6 9 N arto N gt gt gt gt RFI Emission EN55022 Class
23. he network extender Allied Telesyn supplies an approved safety compliant AC power adapter specifically designed for each region the network extender is sold Each type of power adapter has an unregulated output of 12V DCat 1A Note The power adapter mentioned above is not required to be used with the AT MC602 Provider unit because the AT MC602 Provider unit can only be installed in the AT MCR12 chassis AT MC601 and AT MC602 Installation and User s Guide Software Features The AT S57 software used to configure the AT MC601 and AT MC602 network extenders has the following features a a a Determine the VDSL link status Set the upstream and downstream data transfer rates Monitor the status of the VDSL parameters on both the local and remote units Monitor the status of the Ethernet parameters on both the local and remote units Link recovery Note The features listed here are further described in Configuration on page 35 Chapter 2 Installation This chapter contains the installation procedures for the network extenders The installation process is described in the following sections a E E E UE Installation Safety Precautions A Selecting a Site for the Network Extender Required Cables Unpacking the Network Extender Installing the AT MC601 Subscriber Unit Installing the AT MC602 Provider Unit Warranty Registration 20 AT MC601 and AT MC602 Installation and User s Guide Installation Safety Pr
24. he procedure for connecting the management cable is described in Cabling Preparations on page 36 Powering On Power on the Subscriber unit using the power adapter provided as the Subscriber shown in Figure 12 Unit Figure 12 Power On The Subscriber Unit 29 AT MC601 and AT MC602 Installation and User s Guide Installing the AT MC602 Provider Unit The AT MC602 Provider unit can only be installed in an AT MCR12 rackmount chassis A Warning To prevent exposure to electric shock the AT MC602 Provider Unit must be installed in a RESTRICTED ACCESS LOCATION and performed by QUALIFIED SERVICE PERSONNEL Note For Finland Norway and Sweden When the AT MC602 and the AT MCR12 are used a permanent ground conductor must be installed on the AT MCR12 chassis For installation instructions of this ground conductor refer to the AT MCR12 Media Converter Rackmount Chassis Installation Manual PN 613 10725 00 To install the Provider unit in an AT MCR12 rackmount chassis perform the following steps 1 Attach the unit to one of the sliders that will hold the unit in the chassis as shown in Figure 13 Figure 13 Rack Mount Set on Slider 30 AT MC601 and AT MC602 Installation and User s Guide 2 Then set the slider in the chassis as shown in Figure 14 Figure 14 Rack Mount Set in Rack 31 AT MC601 and AT MC602 Installation and User s Guide Cabling the To cable the Provider unit perform the follow
25. hrer Sprache nach Vigtigt Till g C indeholder oversatte sikkerhedsadvarsler der vedr rer installation af dette udstyr N r De ser symbolet amp skal De sla op i tillaeg C og finde de oversatte sikkerhedsadvarsler i Deres eget sprog Belangrijk Appendix C bevat vertaalde veiligheidsopmerkingen voor het installeren van deze apparatuur Wanneer u de 4 ziet raadpleeg Appendix C voor vertaalde veiligheidsinstructies in uw taal Important L annexe C contient les instructions de s curit relatives l installation de cet quipement Lorsque vous voyez le symbole reportez vous l annexe C pour consulter la traduction de ces instructions dans votre langue T rke Liite C sis lt t m n laitteen asentamiseen liittyv t k nnetyt turvaohjeet Kun n et amp symbolin katso k nnetty turvaohjetta liitteest C Importante l Appendice C contiene avvisi di sicurezza tradotti per l installazione di questa apparecchiatura Il simbolo 47 indica di consultare l Appendice C per l avviso di sicurezza nella propria lingua Viktig Tillegg C inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret Nar du ser 47 pner du til Tillegg C for finne den oversatte sikkerhetsinformasjonen p nsket spr k Importante O Anexo C cont m advert ncias de seguran a traduzidas para instalar este equipamento Quando vir o s mbolo 47 leia a advert ncia de seguran a traduzida no seu idioma no Anexo C Importa
26. ignments Table 1 VDSL RJ 11 Port Pinouts Pin Assignment 1 pass through 6 2 pass through 5 3 Ethernet and phone ring 4 Ethernet and phone tip 5 pass through 2 6 pass through 1 PSTN Port 10 100 Mbps Twisted Pair Ethernet Port AT MC601 and AT MC602 Installation and User s Guide The PSTN port allows you to connect the AT MC601 Subscriber unit to a telephone and the AT MC602 Provider unit to the outside telco box This port features an RJ 11 connector Table 2 lists the RJ 11 port pinouts and their assignments Table 2 PSTN RJ 11 Port Pinout Pin Assignment 1 pass through 1 6 2 pass through 2 5 3 Ethernet and phone ring 4 Ethernet and phone tip 5 pass through 5 2 6 pass through 6 1 The AT MC601 and AT MC602 network extenders each have one twisted pair Ethernet port The twisted pair ports feature RJ 45 connectors with a maximum operating distance of 100 meters 328 feet For the port pinout details refer to RJ 45 Port Pinouts on page 15 Type of Cabling The 10 100Base TX twisted pair port on the AT MC601 and AT MC602 network extenders are designed to operate with Category 3 or better unshielded twisted pair cables For 10 Mbps operation on the twisted pair ports Category 3 or better 100 ohm unshielded twisted pair cabling is required For 100 Mbps operation on the twisted pair ports Category 5 and Enhanced Category 5 5E 100 ohm unshielde
27. including the following 1 Donotusethis product near water for example near a bathtub washbowl kitchen sink or laundry tub in a wet basement or near a swimming pool 2 Avoid using a telephone other than a cordless type during an electrical storm There may be remote risk of electric shock from lightning 3 Donotuse the telephone to report a gas leak in the vicinity of the leak Caution To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord Caution Mechanical Mounting The attached rackmounting ears must be used to securely mount the device onto the rack 22 AT MC601 and AT MC602 Installation and User s Guide Selecting a Site for the Network Extender Observe the following requirements when choosing a site for your network extender a a D D D O Make sure that the AT MC602 Provider unit is installed in the AT MCR12 chassis If you plan to install the AT MCR12 in an equipment rack check to be sure that the rack is safely secured and that it will not tip over Devices in a rack should be installed starting at the bottom with the heavier devices near the bottom of the rack If you are installing the network extender on a table be sure that the table is level and secure The power outlet for the network extender should be located near the unit and should be easily accessible The site should provide for easy access to the ports on the front of the network ex
28. ing steps Provider Unit 1 First connectthe Ethernet cable from the Ethernet port to the Service Provider box in your wiring closet as shown in Figure 15 Internet Service Provider Figure 15 Ethernet to Internet Service Provider 2 Then connect a telephone line cable from the PSTN port to the outside telco box as shown in Figure 16 Figure 16 PSTN to Telco PBX Line 32 AT MC601 and AT MC602 Installation and User s Guide 3 Next connect a telephone line cable from the VDSL Line port to the wall interior telephone line as shown in Figure 17 so that the Provider unit can communicate with the Subscriber unit Wall Interior Phone Line p _ A Figure 17 VDSL Line to Wall Interior Phone Line Note The procedure for connecting the management cable is described in Cabling Preparations on page 36 Powering On Powering on the AT MC602 Provider Unit requires that the host the Provider equipment AT MCR12 rackmount chassis is powered on as well For Unit detailed information on how to power on the AT MCR12 unit refer to the AT MCR 12 Media Converter Rackmount Chassis Installation Manual 33 AT MC601 and AT MC602 Installation and User s Guide Warranty Registration When you have finished installing the network extender register your product by completing the enclosed warranty card and mailing it to Allied Telesyn 34 Chapter 3 Configuration The configuration software allows you to a
29. l lovgivning for elektriske installationer 57 AT MC601 and AT MC602 Installation and User s Guide Eisen Dit product voldoet aan de volgende eisen s 1 RFI Emissie EN55022 Klasse A FCC Part 15 Klasse A C TICK Gs 2 Immuniteit EN55024 Gs 3 Electrische Veiligheid EN60950 UL60950 FCC Part 68 Veiligheid G 4 A Stroom mag alleen via de adapter naar het apparaat toegevoerd worden Europe EC Gebruik een door TUV gekeurde wisselstroomadapter van 12 Vdc 500 mA amp 5 Waarschuwing Het toestel wordt uitgeschakeld door de stroomkabel te ontkoppelen Om het toestel stroomloos te maken de stroomkabel ontkoppelen 6 Gevaar Voor Blikseminslag Gevaar NIET aan toestellen of KABELS WERKEN bij BLIKSEM amp 7 N Ventilatiegaten niet blokkeren 68 N Sluit geen telefoonlijn aan op de signaalverbinding 6 9 A Bedrijfstemperatuur De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius amp 10 A Alle Landen het toestel installeren overeenkomstig de lokale en nationale elektrische voorschriften 58 AT MC601 and AT MC602 Installation and User s Guide Normes ce produit est conforme aux normes de suivantes s 1 Eemission d interf rences radio lectriques EN55022 Classe A FCC Part 15 Classe A C TICK amp 2 Immunit EN55024 3 S curit lectrique EN60950 UL60950 FCC Part 68 S curit G 4 A L alimentation du concentrateur doit tre uniquement fournie par Padaptateur Europe EC
30. lation iinan A E E EE EE E E E E EE A E ti Installation Safety Precautions Additional Compliance Warning Statements inner 22 Selecting a Site for the Network Extender ssrrsseresssseresssevessseresssserssssersssseresssesrsssseressseresssesssssserssseeresssesessseersssseresssesesssssrenssesesssseressserenesee 23 Cables Not IC Ue ist er sia 24 Unpacking the Network Extender sn 25 Installing the AT MC601 Subscriber Unit 1 26 Using the Subscriber Unit on a Desktop 26 Wall Mounting the Subscriber Unit 27 cabling the Subscriber Unit tn tei t t vasem eu av ma o ee amet ae 28 Powering On the Subscriber Unit tet e AO ab data 29 AT MC601 and AT MC602 Installation and User s Guide Installing the AT MC602 Provider Unit sn 30 Cabling the Provider Unit nr ater 32 Powering On the Provider Unit nes 33 MEE A E CL EEN 34 Chapter 3 Configuration e 35 Starting a Configuration Session 36 Downloading Software Updates 36 Cabling Preparations 36 Opening the Configuration Software een 37 Configuring the Provider Unit oeste tte RR CO UN BIER CIT Ethernet Status Configuring the Subscriber Unit Chapter 4 Appendix A Default Configuration Settings as n EN I RO I nes int 51 Appendix B Technical Specifications ree erat
31. low Use the tabs at the top of the menu to toggle between these screens When you have finished viewing or adjusting the parameters on the menu screens click the Close button on the bottom right of the menu to exit from the configuration software The Configuration screen displayed in Figure 21 is shown first by default S AT MC60x Configurator link DOWN Configuration VDSL Status Ethernet Status Upstream r Downstream Actual Mbps 11 26 Actual Mbps 2B Min Mbps 0 34 v Min Mbps 0 94 m Max Mbps 0 94 Max Mbps 0 94 v Status Low gt HIGH v About Close Figure 21 Configuration The parameters on the Configuration screen are described below Upstream Downstream The upstream and downstream data transfer rate 38 AT MC601 and AT MC602 Installation and User s Guide A Actual Mbps Displays the actual data transfer rate on the line The software automatically detects this speed Q Min Mbps Allows you to adapt the data transfer rate by setting a minimum speed Q Max Mbps Allows you to adapt the data transfer rate by setting a maximum speed The maximum and minimum speeds in Mbps available in the pull down menus are 0 94 1 06 1 41 1 88 2 11 2 81 3 75 4 22 5 63 7 50 8 44 11 26 15 01 16 88 upstream only Status This field will display Select speed to set until you have selected data rates from the upstream and downstream pull down menus
32. ng Default Provider Parameters Monitored Local Provider Speeds Upstream Max 94 Mbps Upstream Min 94 Mbps Downstream Max 94 Mbps Downstream Min 94 Mbps Flow Low to High Selected Ethernet Port Duplex Mode Auto Negotiate Speed Auto Negotiate MDI MDI X Auto Link Recovery Subscriber Unit Mode Normal 51 Appendix B Technical Specifications Physical Specifications Dimensions WxDxH 109 mm x 95 mm x 25 mm 4 29 in x 3 74 in x 0 98 in Weight 27 kg 0 6 Ibs Recommended Minimum Clearance on All Sides 5 08 cm 2 0 in Environmental Specifications Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 25 C to 70 C 13 F to 158 F Operating Humidity 596 to 9096 noncondensing Storage Humidity 596 to 9596 noncondensing Operating Altitude 3 000 m approx 10 000 ft Non operating Altitude 4 000 m approx 13 100 ft Power Specifications Power Consumption 6 Watts Input Supply Current 500 mA Input Supply Voltage 12V DC 52 AT MC601 and AT MC602 Installation and User s Guide Safety and Electromagnetic Compatibility Certifications Emission EN55022 Class A FCC Part 15Class A C TICK Immunity EN55024 Safety EN60950 UL60950 FCC Part 68 53 Appendix C Translated Electrical Safety and Emission Information Important This appendix contains multiple language translations for the safety statements in this guide Wichtig Dieser Anhang enth lt bersetzu
33. ngen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen Vigtigt Dette tillaeg indeholder overseettelser i flere sprog af sikkerhedsadvarslerne i denne h ndbog Belangrijk Deze appendix bevat vertalingen in meerdere talen van de veiligheidsopmerkingen in deze gids Important Cette annexe contient la traduction en plusieurs langues des instructions de s curit figurant dans ce guide T rke Tama liite sis lt t ss oppaassa esiintyv t turvaohjeet usealla kielell Importante questa appendice contiene traduzioni in piu lingue degli avvisi di sicurezza di questa guida Viktig Dette tillegget inneholder oversettelser til flere spr k av sikkerhetsinformasjonen i denne veiledningen Importante Este anexo cont m tradu es em v rios idiomas das advert ncias de seguran a neste guia Importante Este ap ndice contiene traducciones en m ltiples idiomas de los mensajes de seguridad incluidos en esta gu a Obs Denna bilaga inneh ller flerspr kiga vers ttningar av s kerhetsmeddelandena i denna handledning 54 AT MC601 and AT MC602 Installation and User s Guide Standards This product meets the following safety standards U S Federal Communications Commission Radiated Energy Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection a
34. nications Commission rules FCC Part 68 Product Identifier This equipment complies with Part 68 if the FCC rules and the requirements adopted by the ACTA On the bottom of the equipment is a label that contains among other information a product identifier in the following format US ASTOTOOBMC60X If requested this number must be provided to the telephone company Industry Canada This equipment complies with Industry Canada CS03 Standard Certificate Number IC 336A MC60X This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Warning In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures w AT MC601 and AT MC602 Installation and User s Guide RFI Emission EN55022 Class A FCC Part 15 Class A C TICK amp 1 Immunity EN55024 amp 2 Electrical Safety EN60950 UL60950 FCC Part 68 amp 3 Important Appendix C contains translated safety statements for installing this equipment When you see the amp go to Appendix C for the translated safety statement in your language Wichtig Anhang C enth lt bersetzte Sicherheitshinweise f r die Installation dieses Ger ts Wenn Sie amp sehen schlagen Sie in Anhang C den bersetzten Sicherheitshinweis in I
35. nte El Ap ndice C contiene mensajes de seguridad traducidos para la instalaci n de este equipo Cuando vea el s mbolo Gs Vaya al Ap ndice C para ver el mensaje de seguridad traducido a su idioma Obs Bilaga C inneh ller versatta s kerhetsmeddelanden avseende installationen av denna utrustning N r du ser skall du g till Bilaga C for att l sa det versatta s kerhetsmeddelandet p ditt spr k Contents Electrical Safety and Emission Statement ENEE 3 Pref ce RR How This Guide is Organized ja DOCUMENTCONVENTION Siamin sa sade Contacting Allied Telesyn Technical Support esse 9 Online Support ENEE 9 E mail and Telephone Support 9 Returning Products eneen 9 For Sales or Corporate Information sense 9 Obtaining Management Software Updates EENEG 9 Chapter 1 Product Description ENEE 10 Summary 0f Features a ca E SS Ea teo Lee edens a 10 OVERVIEW sil M 11 Location of Components reete ete o da ate EE eiie reete test AA S iei pe oet doces 12 Hardware Features srs ann Bets vali a Ua e amete edet ete tae ie ini iui 13 VDSL Line Port 13 PSTN Port 14 10 100 Mbps Twisted Pair Ethernet Port m Status LEDS EUR MGMT Kn lee a nine dentaal pl ta inca Management Cable eme ems AC Power Supply Input Port assor Bl pude da vahdi t dc External AC DC Power Adapter Software Features Enn Chapter 2 Instal
36. on on page 36 and then continue with the instructions in this section After you have selected the correct port and clicked the OK button the AT MC60x Configurator Select Mode screen will appear as displayed in Figure 25 Select Mode Normal Install ove Figure 25 Select Mode There are two options on the Select Mode screen Normal and Install These options are described below Normal The Normal mode sets the units to operate under normal parameters The units will attempt to establish a link using the parameters you set on the Configuration screen while connected to the Provider unit See Configuration on page 38 for a description of the Configuration screen Using the Normal mode will only allow the units to establish links that meet the criteria you have set The disadvantage to using the Normal mode is that if either of the upstream or downstream speeds you have set are unattainable the link attempt will fail because the units are not set to use the default parameters as back ups Install The Install mode enables a watchdog timer to monitor the link attempt process If the network extenders are not able to establish a link using the parameters you set on the Provider unit within a reasonable amount 45 AT MC601 and AT MC602 Installation and User s Guide of time a timeout will occur After a timeout the default configuration parameters will be used to establish a link with the highest possibl
37. ositivo de desconex o Para deseletrificar o equipamento desconecte o cabo de ALIMENTA O ES 6 Perigo De Choque Causado Por Raio Perigo N O TRABALHE no equipamento ou nos CABOS durante per odos suscet veis a QUEDAS DE RAIO 7 N N o bloqueie as aberturas de ventila o 68 N N o conecte uma linha telef nica ao conector de sinal 6 9 A Temperatura De Funcionamento Este produto foi projetado para uma temperatura ambiente m xima de 40 graus cent grados amp 10 Todos Os Pa ses Instale o produto de acordo com as normas nacionais e locais para instala es el tricas 63 AT MC601 and AT MC602 Installation and User s Guide Est ndares Este producto cumple con los siguientes est ndares s 1 Emisi n RFI EN55022 Clase A FCC Part 15 Clase A C TICK Gr 2 Inmunidad EN55024 a 3 Seguridad el ctrica EN60950 UL60950 FCC Part 68 Seguridad GS 4 A La energ a para el dispositivo central o hub debe provenir nicamente del adaptador Europe EC Utilizar un adaptador de corriente alterna autorizado TUV de 12 Vdc 500 mA amp 5 Atencion El cable de alimentacion se usa como un dispositivo de desconexion Para desactivar el equipo desconecte el cable de alimentaci n amp 6 Peligro De Rayos Peligro NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los equipos o en LOS CABLES durante TORMENTAS ELECTRICAS e N No bloquee las aberturas para ventilacion G 8 A No conectar ninguna l nea telef nica al con
38. ould like to verify that you are using the latest version of the configuration and management software click the About button on the bottom right of the AT MC60x Configurator pop up The About AT MC60x Configurator pop up will appear as shown in Figure 20 About AT MC60x Configurator x AT MC60x Configurator Version 2 0 0 Nn Allied Telesyn Copyright C 2001 Figure 20 About AT MC60x Configurator Select the computer port you are using from the pull down menu on the AT MC60x Configurator pop up and click OK If you are connected to the AT MC602 Provider unit and want to configure the network extenders continue with the next section Configuring the Provider Unit on page 38 If you are connected to the AT MC601 Subscriber unit to attempt link recovery continue with Configuring the Subscriber Unit on page 45 37 AT MC601 and AT MC602 Installation and User s Guide Configuring the Provider Unit Configuration After performing the procedure described in the previous section Starting a Configuration Session on page 36 if you are connected to the Provider unit the AT MC60x Configurator menu will appear The Configurator bar at the top of the menu indicates whether or not the Provider unit has established an Ethernet link by displaying link DOWN or link UP in brackets The AT MC60x Configurator menu has three screens Configuration VDSL Status and Ethernet Status The parameters on these screens are described be
39. ow then a reduced constellation link can be established and the software can automatically configure the Subscriber unit parameters TC Synchronized Transmission convergence is synchronized Ethernet Encapsulation Sync The process of encapsulating packets into frames at the VDSL link level is synchronized Remote I F Synchronized Remote interface is synchronized Signal Detected The VDSL signal is being detected by the software Link Fail Counter Number of unsuccessful link attempts Micro Interruption Occurred A micro interruption occurred AGC Converged Automatic gain control has converged on the VDSL link Timing Converged The timing acquisition function is converged This only occurs on the Subscriber remote unit ADC Saturation Analog to digital converter has been overloaded with interference Local Remote Select Local to view the parameters for the Provider unit Select Remote to view the parameters for the Subscriber unit The Remote option will only be available when an active link has been established To view the Ethernet Status screen click on the Ethernet Status tab at the top of the menu 42 AT MC601 and AT MC602 Installation and User s Guide The Ethernet Status screen is displayed in Figure 24 AT MC60x Configurator link DOWN Figure 24 Ethernet Status The parameters on the Ethernet Status screen are described below TxRx Counters The data fields in this section indicate the number and
40. reiki SS 8 N l liit puhelinlinjaa signaalin liittimeen amp 9 N K ytt l mp tila T m tuote on suunniteltu ymp r iv n ilman maksimil mp tilalle 40 C amp 10 A Kaikki Maat Asenna tuote paikallisten ja kansallisten s hk turvallisuusm r ysten mukaisesti 60 AT MC601 and AT MC602 Installation and User s Guide Standard Questo prodotto conforme ai seguenti standard 1 Emissione RFI interferenza di radiofrequenza EN55022 Classe A FCC Part 15 Classe A C TICK 2 Immunit EN55024 3 Sicurezza elettrica EN60950 UL60950 FCC Part 68 Norme Di Sicurezza amp 4 N Questo dispositivo deve essere alimentato solo mediante l adattatore Europe EC 7 Utilizzare Padattatore per c a da 12 Vdc 500 mA conforme alla normativa TUV 5 Attenzione Il cavo di alimentazione amp usato come dispositivo di disattivazione Per togliere la corrente al dispositivo staccare il cavo di alimentazione 6 Pericolo Di Fulmini Pericolo NON LAVORARE sul dispositivo o sui CAVI durante PRECIPITAZIONI TEMPORALESCHE e A Non ostruire le prese d aria G 8 A Non collegare una linea telefonica al connettore del segnale 9 Temperatura Di Funzionamento Questo prodotto amp concepito per una temperatura ambientale massima di 40 gradi centigradi 5 10 N Tutti I Paesi installare il prodotto in conformit delle vigenti normative elettriche nazionali 61 AT MC601 and AT MC602 Installation and User s Guide Sikkerhet
41. rmation Warning Warnings inform you that performing or omitting a specific action may result in bodily injury Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data AT MC601 and AT MC602 Installation and User s Guide Contacting Allied Telesyn Technical Support Online Support E mail and Telephone Support Returning Products For Sales or Corporate Information Obtaining Management Software Updates This section provides Allied Telesyn contact information for technical support as well as sales or corporate information You can request technical support online by accessing the Allied Telesyn Knowledge Base from the following web site http kb alliedtelesyn com You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions For Technical Support via E mail or telephone refer to the Support amp Services section of the Allied Telesyn web site http www alliedtelesyn com Products for return or repair must first be assigned a Return Materials Authorization RMA number A product sent to Allied Telesyn without a RMA number will be returned to the sender at the sender s expense To obtain a RMA number contact Allied Telesyn s Technical Support at our web site http www alliedtelesyn com You can contact Allied Telesyn for sales or corporate information at our web site http
42. snormer Dette produktet tilfredsstiller folgende sikkerhetsnormer s 1 RFI str ling EN55022 Klasse A FCC Part 15 Klasse A C TICK Gs 2 Immunittet EN55024 Gs 3 Elektrisk sikkerhet EN60950 UL60950 FCC Part 68 Sikkerhet GA N All str mtilf rsel m komme fra adapteren Europe EC Benytt TUV godkjent AC adapter p 12 Vdc 500 mA milliampere amp 5 Forsiktig Str mledningen brukes til frakoble utstyret For deaktivisere utstyret m str mforsyningen kobles fra ES 6 Fare For Lynnedslag Fare ARBEID IKKE p utstyr eller KABLER i TORDENVZER TT A Blokker ikke luftventilene SS 8 N Telefonlinje m ikke koples til signalkontakten GS 9 N Driftstemperatur Dette produktet er konstruert for bruk i maksimum romtemperatur p 40 grader celsius amp 10 N Alle Land Produktet m installeres i samsvar med de lokale og nasjonale elektriske koder 62 AT MC601 and AT MC602 Installation and User s Guide Padr es Este produto atende aos seguintes padr es Gs 1 Emiss o de interfer ncia de radiofrequ ncia EN55022 Classe A FCC Part 15 Classe A C TICK 2 Imunidade EN55024 6 3 Seguranca el ctrica EN60950 UL60950 FCC Part 68 Seguranca G 4 A Use somente o adaptador fornecido para alimenta o el trica do hub Europe EC Use um adaptador de corrente alternada com sa da DC de 12 Vdc 500 mA em conformidade com as especifica es da TUV 5 N Cuidado O cabo de alimenta o utilizado como um disp
43. tender This will make it easy for you to connect and disconnect cables as well as view the LEDs To allow proper cooling of the network extender air flow around the unit and through its vents on the side should not be restricted Do not place objects on top of the network extender Do not expose the network extender to moisture or water Make sure that the site is a dust free environment You should use dedicated power circuits or power conditioners to supply reliable electrical power to the network extenders 23 Cables Not Included AT MC601 and AT MC602 Installation and User s Guide The AT MC601 and AT MC602 network extenders require the three cables described in Table 6 below These cables are not included with the network extenders Port Table 6 Cables Cable Connector Ethernet Category 3 or better 100 ohm unshielded straight through or crossover twisted pair cable RJ 45 PSTN standard telephone cable RJ 11 VDSL Line standard telephone cable RJ 11 24 AT MC601 and AT MC602 Installation and User s Guide Unpacking the Network Extender To unpack the network extender 1 Remove all components from the shipping package and store the packaging material in a safe location Note You must use the original shipping material if you need to return the unit to Allied Telesyn 2 Place the network extender on a level secure surface 3 Make sure the following hardware
44. the Subscriber the bottom of the unit The screws and plastic anchors used for Unit mounting the unit are provided To wall mount the Subscriber Unit perform the following procedure 1 If attached remove the protective feet data cables and power cord from the unit 2 Selecta wall location for the device Install the screws and plastic anchors onto the wall as shown in Figure 7 MVA Figure 7 Installing the Screws and Plastic Anchors Onto The Wall 4 Position the switch onto the wall screws so that the ports are facing the ceiling as shown in Figure 8 NNNNNNNNNNNNNNNN j Figure 8 Positioning The Switch Onto The Wall Screws 27 AT MC601 and AT MC602 Installation and User s Guide Cabling the To cable the Subscriber unit perform the following steps Subscriber Unit i 1 First connect the Ethernet cable from the Ethernet port to the Ethernet port on the computer as shown in Figure 9 Figure 9 Ethernet to Computer 2 Then connect a telephone line cable from the PSTN port to the telephone as shown in Figure 10 Figure 10 PSTN to Telephone 28 AT MC601 and AT MC602 Installation and User s Guide 3 Next connect a telephone line cable from the VDSL Line port to the wall interior telephone line as shown in Figure 11 so that the Subscriber unit can communicate with the Provider unit Wall Interior Phone Line Figure 11 VDSL Line to Wall Interior Phone Line Note T
45. type of frames that have been transmitted and received via the Ethernet link Collision Counters The data fields in this section indicate the number and type of collisions that have occurred on the Ethernet link Error Counters The data fields in this section indicate the number and type of errors that have occurred on the Ethernet link Clear This button allows you to reset the counters clearing the values previously recorded by the software 43 AT MC601 and AT MC602 Installation and User s Guide Stop Start This button allows you to pause counting When you press Stop the counters remain at their present values When you press Start the counters continue adding to the values already recorded by the software Local Remote Select Local to view the parameters for the Provider unit Select Remote to view the parameters for the Subscriber unit The Remote option will only be available when an active link has been established 44 AT MC601 and AT MC602 Installation and User s Guide Configuring the Subscriber Unit In rare instances you may need to use the configuration software on the Subscriber unit to attempt link recovery If the configuration software detects a problem with the Subscriber unit while you are connected to the Provider unit it will prompt you to use the software on the Subscriber unit by displaying a pop up error message On these occasions follow the procedure described in Starting a Configuration Sessi
46. uplex mode can send and receive data simultaneously The best network performance is achieved when an end node can operate at full duplex since the end node is able to send and receive data simultaneously The AT MC601 and AT MC602 network extenders can operate in either half or full duplex mode The network extender can operate with end nodes capable of either half duplex full duplex or that can Auto Negotiate the duplex mode However it is important to remember that the two end nodes connected to the ports on the network extenders must be able to operate in the same duplex mode RJ 45 Port Pinouts Figure 4 illustrates the pin assignments of an RJ 45 connector and port ua lg Lei 1 8 1 Figure 4 RJ 45 Connector and Port Pin Assignments Table 3 lists the RJ 45 10Base T 100Base TX connector pins and their signals when the port is operating in either MDI or MDI X configuration Table 3 RJ 45 Port Pinouts Pin MDI Signal MDI X Signal 1 TX RX 2 TX RX 3 RX TX 6 RX TX Status LEDs AT MC601 and AT MC602 Installation and User s Guide The AT MC601 and AT MC602 network extenders feature the following status LEDs L Power Q Ethernet link and activity A VDSL Line link and error Table 4 defines the LEDs for the AT MC601 and AT MC602 network extenders Table 4 Status LEDs LED Color Description PWR Green Power is applied to the unit 10 100Base TX Port
47. your computer is not responding in which case you should re start your computer and try again Q Communication error the program will be closed Verify serial connection and restart the program as shown in Figure 28 Fatal Error Communication error the program will be closed Verify serial connection and restart the program Figure 28 Communication Error Message 48 AT MC601 and AT MC602 Installation and User s Guide If you are unable to establish a configuration session with the network extender and receive this error message checkto be sure that the management cable is securely connected to the management port on the network extender and to the RS 232 port on the computer Then make sure you are selecting the correct COM1 or COM2 port at the software prompt Q Max speed cannot be lower than min speed select different values This error message occurs when you select a maximum speed that is lower than the set minimum speed during the selection of speed ranges on the rate adaptation section on the Configuration menu screen Select a higher maximum value to correct the problem P side must be connected to start this procedure or S side must be connected to start this procedure These error messages occur when the management cable is connected to the wrong unit for the procedure you are trying to perform This could happen if you switch the management cable between the units without closing the software window
Download Pdf Manuals
Related Search
Related Contents
Exibição de fotos e vídeos um a um Télécharger le fichier Samsung 932MP Manuel de l'utilisateur Residents Manual Anleitung BMH 33-60S_SPK2:_ loewe e3000 chassis tv user manual COBY electronic DVD627 User's Manual Talc n° 2 blanc Charge de stucture lamellaire, bon grade de User Manual - Pacific-Wave American Dryer Corp. AD-24 User's Manual Copyright © All rights reserved.