Home
Air Oasis (120v) User's Manual
Contents
1. on the mounting plate that can be used as a guide Its recom mended to seal the edges of the mounting plate using aluminum insulation tape Contaminants 4
2. 911 org Step 4 Reverse steps 1 3 to set new AHPCO Cell in place Be sure to place the exposed tip of the fiber optic cord between the first rings of the new AHPCO Cell and in close proximity to the UV lamp This will ensure the indicator light functions properly Replacement Date Reminder The AHPCO Cell should be replaced every three years 3 Years Date 6 Years Date 9 Years Date Hg lamp contains mercury Manage in accord with disposal laws Find disposal centers at www earth911 org 6 Dual Induct Installation Instructions Step 1 Tear out the cut out template and trace the rectangle onto the ductwork Step 2 Drill holes at each corner of the rect angle Step 3 Cut the rectan gle out of the ductwork with a jig saw or a pair of metal cutting snips Step 4 s Remove the wax paper from the gasket Step 5 Insert unit into pre cut hole Step 6 Drill the metal tapping screws in to fs amp hold unit in place Tear this page off and cut the rectangle out Then place on the duct work in desired position and trace the rect angle Drill holes as indicated and then use a jig saw or metal cutting snips to cut out the rectangle CutOut Step 4 Plug the power cord into an electrical outlet You may optionally have an electrician wire the air purifier to your HVAC unit so that the air purifier only operates when your HVAC fan is running Once th
3. Troubleshooting Guide Problem Reason Solution Unit does not turn on 1 Power Cord 1 Check to make sure power cord is plugged in or properly connect ed to HVAC unit 2 Check to make sure UV lamp within AHPCO Cell in plugged in completely 2 AHPCO Cell Dual Induct 3 Make sure exposed 3 Indicator Light Not end of black fiber optic 1 20v Working cord is exposed to the UV light Owner s Manual This Manual Includes e Warranty e Safety Warnings e Installation Instructions e Operating Instructions e Replacement Directions e Troubleshooting Tips Amarillo TX 79118 l l A Before operating this unit or replacing the AHPCO Toll Free 1 800 936 1764 Fax 1 806 373 7799 Cell carefully read the contents of this manual www AirOasis com Copyright 2006 Air Oasis All Rights Reserved Important Safety Instructions When operating electrical appliances basic precautions should always be fol lowed WARNING To reduce the risk of fire electric shock or injury e Do not use outdoors or on wet surfaces e Use only as described in this manual e Do not use with damaged cord or plug If appliance is not working as it should has been dropped damaged left outdoors or dropped into water call customer service at 1 800 936 1764 e Do not unplug by pulling on cord To unplug grasp the plug not the cord e Do not handle plug or appliance with wet hands e Do not put any object into o
4. e unit is plugged in the indicator light should glow to indicate the AHPCO Cell is working properly Indicator Light Step 1 CAUTION Before attempting to service the Air Oasis unit be sure the power is off and unplugged f Remove three 3 screws at the top of the aluminum face plate Then slide the face plate up and off Step 2 Unplug the four pin lamp connec tors and fiber optic cords from the AHPCO Cell T Read all instructions carefully before operating your air purifier Table of Contents Safety Instructions and Cautions Table of Contents Warranty Maintenance and Customer Service Placement and Operation Cleaning AHPCO Cell Replacement Troubleshooting Guide 5 6 Warranty Air Oasis gives you the following limited warranty for this product only if it was origi nally purchased for residential or commercial use but not resale from Air Oasis or an Air Oasis Authorized Retail Dealer Air Oasis will repair or replace free of charge to the original purchaser any part that is found to be defective in material or workmanship within three 3 years of the date of purchase This limited warranty covers the replacement of a defective AHPCO Cell for a pe riod of three years This limited warranty does not apply to any part subjected to accident abuse cer tain commercial uses alteration misuse damage caused by act of God the use of voltages other than indicated on the label disp
5. layed on this product or service of this product by anyone other than Air Oasis Air Oasis does not authorize any person or representative to assume or grant any other warranty obligation with the sale of this product Air Oasis limited warranty is valid only if you retain proof of purchase from Air Oa sis or an Air Oasis Authorized Retail Dealer for this product If you purchase this product from any other source your purchase is AS IS which means Air Oasis grants you no warranty and that you not Air Oasis assume the entire risk of the quality and performance of this product including the entire cost of any necessary servicing or repairs of any defects Air Oasis liability for damages to you for any costs whatsoever arising out of this statement of limited warranty shall be limited to the amount paid for this product at the time of original purchase and Air Oasis shall not be liable for any direct indirect consequential or incidental damages arising out of the use or inability to use this product ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT INCLUD ING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE WARRANTY PERIOD AND NO WARRANTIES WHETHER EXPRESS OR IMPLIED WILL APPLY AFTER THIS PERIOD Some states do not allow limitations on the duration of implied warranties so the above limitation may not apply to you This warranty gives you specific legal right
6. penings e Turn off all controls before unplugging A CAUTION A AHPCO Cell contains Hg Mercury and should be disposed of according to disposal laws Find disposal centers at www earth911 org If the UV lamp is broken do not touch the cell or glass with your hands UV lamp may be hot and could cause serious burns if not handled properly Please wait until the AHPCO Cell has cooled to room temperature to remove from unit WARNING UV Light Hazard Harmful to skin and eyes Can cause temporary or permanent loss of vision Never look at the lamp while illuminated To prevent exposure to ultraviolet light be sure the pow er is disconnected before servicing WARNING RISK OF ELECTRICAL SHOCK CAN CAUSE INJU RY OR DEATH UNPLUG OR DISCONNECT UNIT FROM POWER SUPPLY BEFORE SERVICING Disclaimer The health aspects associated with the use of this product and its ability to aid in disinfection of environment air have not been investigated by UL located on front panel of fixture and in the instruction manual Step 3 Remove four 4 wing nuts secur ing the AHPCO Cell in place Then slide the AHPCO Cell up and out of the unit A CAUTION A UV lamp may be hot and could cause serious burns if not handled properly Please wait until AHPCO Cell has cooled to room tempera ture to remove from unit AHPCO Cell contains Hg Mer cury and should be disposed of according to disposal laws Find disposal centers at www earth
7. s and you may also have other rights which vary from state to state To obtain warranty service and return authorization number contact us at PH 800 936 1764 FAX 806 373 7799 or E mail to feedback airoasis com NOTE All returned packages that do not have an RMA will be refused 3 Maintenance and Customer Service If you require any additional information or have problems with your Air Oasis ap pliance you may call Air Oasis customer service at 1 800 936 1764 Please have your serial and model numbers found on bottom of the unit handy when calling Save your sales receipt to show if your Air Oasis appliance should ever need any warranty service Installation and Operation T Its strongly recommended that only a licensed electrician or HVAC installer properly install this unit The purifiers can be installed on either the return or supply side of the plenum Step 1 Cut a 3x5 hole in the plenum using a jig saw Make sure the hole is centered so that no part of the mounting plate is hang p ing off the edges of the plenum when the pe probe is inserted 7 E Step 2 Insert the probe into the 3 x5 hole until the back mounting plate is flush against the plenum surface We recommend mounting the unit with the rectangular side facing ei ther left or right but not down or up Step 3 Attach the mounting plate to the plenum surface using sheet metal screws There are predrilled holes
Download Pdf Manuals
Related Search
Related Contents
ORiNプロバイダ登録チェックリスト User`s Manual of ISaGRAF Embedded Controllers Frigidaire FGVU21F8QT Product Specifications Sheet 製品カタログ(PDF257KB) CANTIERE - Università degli Studi di Roma Tor Vergata HDL演習 Instructions for use Samsung S27E510C Manual de Usuario Copyright © All rights reserved.
Failed to retrieve file