Air King AIG6 User's Manual
Contents
1. 8 Wing Nut Washer Handle Y Transition _ Figure 8 4 Adjust the damper to balance airflow and tighten the wing nut to secure SECTION 8 Wiring the Fan CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION CAUTION ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES ORDINANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN 1 Remove the screws securing the terminal box cover plate located on the side of the motor Figure 9 5S7635036 New 9 06 WWW AIRKINGLIMITED COM 2 Run wiring from an approved wall switch carrying the appropriate rating One neutral white and one hot black lead connected to the switch Secure the electrical wires to the housing with an approved electrical connector Make sure you leave enough wiring in the terminal box to make the connections to the fan s pre wired electrical terminal strip 3 Insert the white wire from the house into the terminal strip port labeled N and tighten using a small regular screwdriver Insert the black wire from the wall switch into the terminal strip port labeled L and tighten using a small regular screwdriver Since the motor is isolated within a plastic housing grounding is not necessary Figure 10 Supply from house poy joe g 4 Ch
2. AIG6 5S7635015 Plaque de finition AIF4X 5S7635029 Plaque de finition AIF6X Grille AIG4 5S7635016 5S7635030 Grille AIG6 987635017 Plaque de finition AIF8X AIF10X 597635031 Vis AIF4X 597699021 Vis AIF6X AIF8X AIF10X 587699023 Support de montage AIF4X AIF6X 587635035 Support de montage AIF8X AIF10X 587635034 Passe c ble 5S7699020 5S7635036 New 9 06 Vis 5S7699024 WWW AIRKINGLIMITED COM Ressorts pour la grille 5S7635028 12 of 12
3. Bien lire toutes les instructions avant d installer ou d utiliser endommager le filage lectrique et autres utilit s cach es le ventilateur d vacuation 7 Les ventilateurs avec conduits doivent toujours tre vacu s 2 Utiliser cette unit seulement de la mani re pour laquelle le vers l ext rieur fabricant l a con u Si vous aviez des questions veuillez 8 Pour viter des dommages aux roulements des moteurs et ou contacter le fabricant des h lices bruyantes ou d s quilibr es emp cher la 3 Avant d effectuer un service ou de nettoyer l unit couper poussi re de cloison s che poussi re de construction etc l alimentation lectrique dans le panneau de distribution et d atteindre l unit de puissance verrouiller le dispositif de d connexion afin d viter que 9 Acceptable pour utilisation au dessus d une baignoire ou l alimentation ne revienne accidentellement Lorsque le dispositif d une douche lorsque install dans un circuit prot g par un ne peut tre verrouill fixer solidement un avis d avertissement disjoncteur de fuite de terre tel qu une tiquette au panneau de distribution 4 Le travail d installation et le c blage lectrique doivent tre effectu s par une des personne s qualifi e s en conformit avec tous les codes et normes applicables incluant la construction relative aux incendies 5 De l air en quantit suffisante est requis pour la bonne combustion et l vacuation de gaz par le c
4. l ext rieur par le biais d un capuchon de mur ou de plafond WWW AIRKINGLIMITED COM 9 of 12 REMARQUE Lorsqu un conduit isol flexible est utilis il est recommand de fixer l me de vinyle interne du trou d entr e et de sortie l aide d une vis de serrage ou de ruban adh sif et que le pare vapeur entourant le rev tement isolant soit fix l aide de ruban adh sif au ch ssis du ventilateur REMARQUE Lorsqu il est n cessaire de joindre un conduit flexible l ensemble collet clapet et qu un coude imm diat s av re n cessaire assurez vous qu il s agisse d un coude flexible de sorte assurer le bon fonctionnement des lames du clapet SECTION 7 Installation d un clapet d quilibrage facultatif Certains ensembles incluent un clapet d quilibrage facultatif permettant d ajuster le syst me Le clapet peut tre utilis l o les grilles seront fix es avec des conduits secondaires de longueurs in gales ou l o le d bit devra tre quilibr pour une raison ou une autre Pour installer le clapet en option 1 Le clapet doit tre install sur la branche secondaire la plus facilement accessible II s agit habituellement du conduit le plus court ou de celui avec le moins de coudes 2 Percez un trou de 7 94 mm environ 38 1 mm du bord sur le c t plat de l embranchement en Y 3 Ins rez l arbre du clapet dans le trou perfor l tape 2 Placez la rondelle la poign e et ensui
5. motor WARNING DO NOT USE IN KITCHENS SAVE THESE INSTRUCTIONS WWW AIRKINGLIMITED COM 1 of 12 INSTALLATION INSTRUCTIONS CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION SECTION 1 Preparing for Fan Installation 1 When selecting fan mounting location the following criteria should be considered a Mounting to minimize noise generated by fan operation Mounting the fan as far as possible from the intake point will minimize fan operating noise from being transmitted back through the duct work If the fan is to be used as a booster for moving the air between two rooms a central point along the duct may be optimal Insulated flexible type duct work recommended for all bathroom exhaust applications will result in much quieter operation It is recommended that a minimum 8 of insulated flexible ducting be used between any exhaust grill and fan for low noise level b Service accessibility Fan location should allow sufficient access for service SECTION 2 Installing the Fan 1 Using the 1 wood screws provided attach the fan mounting bracket to a support beam at the selected location Figure 1 Horizontal Mounting V Vertical Mounting ATA NOTE Fan mounting can be at any point along the duct and in any angle however vertical mounting is recommended to reduce condensation buildup in the fan If a horizontal installation is necessary and condensation buildup may
6. pose a problem wrap insulation around the fan to minimize buildup 2 Attach fan to the mounting bracket with the three 7 16 sheet metal screws provided making sure the wiring box is positioned for easy access Figure 2 5587635036 New 9 06 NOTE Bracket is provided with rubber vibration isolation grommets to prevent the transmission of sound through the structure Be careful not to over tighten Also care should be taken not to strip the plastic housing Screws are self tapping and do not require pilot holes Pilot holes no larger than 1 16 can be used to ease the installation however SECTION 3 Installing Supply Exhaust Grill 1 Select the grill mounting point within the area to be ventilated that does not interfere with a ceiling joist To ease installation locations of framing beams within the walls or joists supporting the ceiling should be considered Collar damper is provided with a perforated hanging strap for attachment directly to a beam or joist Allow sufficient space between the collar damper and the beam to attach the duct work If the location of the grill does not allow direct attachment a cross member mounted to the framing should be used 2 Bend the mounting straps attached to the collar outward so they are straight across Figure 3 Mounting Strap Mounting Strap Collar Damper Figure 3 SECTION 4 New Construction 1 Install the collar da
7. Models AIK14X AIK16X AIK24Y AIK26Y IMPORTANT INSTRUCTIONS OPERATING MANUAL AIF4X AIF6Y AIF8X AIF10X AlG4 AIG6 e e Ventilation Products E In Line Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DESCRIBED PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR FUTURE REFERENCE GENERAL SAFETY INFORMATION When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to person including the following WARNING DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED MAKE SURE ELECTRICAL SERVICE TO THE FAN IS LOCKED IN OFF POSITION 1 2 Read all instructions before installing or using exhaust fan Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes
8. Moteur AIK26Y 557635002 Plaque de finition AIK14X 587635029 Plaque de finition AIK16X Plaque de finition AIK24Y 587635029 587635030 Plaque de finition AIK26Y 587635030 Vis AIK14X 597699021 Vis AIK16X Vis AIK24Y 587699021 597699023 Vis AIK26Y 987699023 Support de montage 557635035 Support de montage 987635035 Passe c ble 5S7699020 Passe c ble 5S7699020 Vis 5S7699024 Vis 5S7699024 Vis 5S7699022 Assemblage collet clapet AIK14X Embranchement en Y AIK24Y 5S7635008 5S7635039 Embranchement en Y AIK26Y 597635010 Assemblage collet clapet AIK16X 557635015 Vis 997699022 Grille AIK14X 597635016 Grille AIK16X Assemblage collet clapet AIK24Y 587635039 997635017 Assemblage collet clapet AIK26Y 987635015 fF co co co eIn Ressorts pour la grille 6 Description 587635028 Grille AIK24Y 557635016 Grille AIK26Y 557635017 de pi ce de remplacement Moteur AIF4X 597635028 Moteur AIF6X 5S7635001 Ressorts pour la grille Description 587635028 de pi ce de remplacement Moteur AIF8X 5S7635003 Moteur AIF10X Assemblage collet clapet AIG4 5S7635039 5S7635004 Assemblage collet clapet
9. and standards including fire related construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS 5S7635036 New 9 06 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit Acceptable for use over a bathtub or shower when installed in a GFCI protected branch circuit Suitable for use with solid state speed control This unit has rotating parts and safety precautions should be exercised during installation operation and maintenance Guards must be installed when fan is within reach of personnel or within seven 7 feet of working level or when deemed advisable for safety NEVER place a switch where it can be reached from a tub or shower Do not insert or allow fingers or foreign objects to enter the
10. ate AIK26Y 557635030 Screw AIK14X 587699021 Screw AIK24Y 587699021 Screw AIK16X 987699023 Screw AIK26Y 557699023 Mounting Bracket 587635035 Mounting Bracket 587635035 Grommet 587699020 Grommet 557699020 Screw 587699024 Screw 587699024 Screw 587699022 Y Transition AIK24Y 557635008 Collar Damper Assembly AIK14X 587635039 Y Transition AIK26Y 557635010 Collar Damper Assembly AIK16X 587635015 Screw 987699022 Grill AIK14X 587635016 Collar Damper Assembly AIK24Y 557635039 Grill AIK16X 587635017 Collar Damper Assembly AIK26Y 587635015 SE EN ES EN EEE PO ER EN ES EN ER ER EE Grill Spring 5S7635028 Grill AIK24Y 587635016 Grill AIK26Y 557635017 Description Replacement Part Motor AIF4X 557635028 Motor AIF6X 557635001 Grill Spring Description 557635028 Replacement Part Motor AIF8X 987635003 Collar Damper Assembly AlG4 587635039 Motor AIF10X 587635004 Collar Damper Assembly AIG6 997635015 Cover Plate AIF4X 587635029 Grill AIG4 587635016 Cover Plate AIF6X 587635030 Grill AIG6 587635017 Cover Plate AIF8X AIF10X 587635031 Screw AIF4X 557699021 Screw AIF6X AIF8X AIF10X 587699023 Mounting Bracket AIF4X AIF6X 587635035 Mounting Brack
11. e permettent pas de limitation sur la dur e de la garantie implicite ou l exclusion ou la limitation de dommages indirects ou accessoires ainsi ces limitations et exclusions peuvent ne pas s appliquer vous Cette garantie vous donne des droits l gaux sp cifiques et vous pouvez aussi avoir des droits qui varient d un Etat l autre et d une province l autre POUR DES PIECES OU DE L ASSISTANCE TECHNIQUE Veuillez appeler au 1 800 465 7300 DU LUNDI AU VENDREDI ENTRE 8 00 HRE ET 16 00 HRE HNE VEUILLEZ NE PAS RETOURNER CE PRODUIT A LENDROIT DE L ACHAT D ORIGINE R f rencer le type et le style du produit localis sur l tiquette l int rieur du produit lorsque vous appelez Pour plus d information veuillez visiter le site Web de Air King au www airkinglimited com Installateur Date d installation Endroit de l achat Num ro de mod le 557635036 New 9 06 WWW AIRKINGLIMITED COM 11 of 12 Ensemble de pi ces de remplacement pour ventilateur T T O ititit TIITII orifice d entr e unique 2 D 6 Description DIAGRAMME DES PIECES DE REMPLACEMENT ventilateur orifice d entr e double de pi ce de remplacement Description Ensemble de pi ces de remplacement pour de pi ce de remplacement Moteur AIK14X 5S7635000 Moteur AIK16X Moteur AIK2aY 557635000 597635001
12. e peut tre grill ou un disjoncteur peut tre d cle nch 1a Remplacer le fusible ou r initialiser le disjoncteur l interrupteur est la position en marche 1b Le c blage n est pas raccord correctement alimentation de l unit V rifier que tous les fils sont raccord s La moteur est terminee y la moteur 2 Le ventilateur fonctionne mais l air Obstruction dans les conduits d vacuation V rifi r toute obstruction dans les conduits Les plus courantes sont des circule plus lentement que la normale oiseau dans le chapeau de toit ou mural l o le ventilateur s vacue s vacue vers l ext rieur Le r glage de la commande de vitesse n est pas assez lev Si une commande de vitesse est utilis e confirmez le r glage Cablage incorrect Coupez l alimenta branch s correcte ati ion de l unit Assurez vous que tous les fils sont 3 Le ventilateur fonctionne de mani re Le moteur est l che alimen unit Retirer la grille et v rifier que toutes les plus bruyante que la normale vis sont fr ea serr es Remettre l alimentation sur l unit Les vis pour l installation du ventilateur sont trop serr es Coupez l alimentation de l unit Desserrez les vis des passe c bles en caoutchouc Ventilateur endommag au cours de l exp dition Communiquez avec le vendeur pour un remplacement GARANTIE LIMIT E Tous les produits fabriqu s par Air King Limit
13. eck to make sure all wire connections are securely fastened to the terminal strip and replace the fan terminal box cover 5 Restore power and test your installation SECTION 9 Use and Care CAUTION MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT 1 Cleaning the Grill Remove grill and use a mild detergent such as dishwashing liquid and dry with a soft cloth NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS Completely dry grill before reinstalling Refer to instructions in Step 2 of Section 4 to reinstall grill 2 The fan s bearings are sealed and provided with an internal lubricating material no additional lubrication is necessary 4 of 12 Troubleshooting Guide Probable Cause Suggested Remedy 1 Fan does not operate when the switch is on A fuse may be blown or a circuit tripped Replace fuse or reset circuit breaker Wiring is not connected properly Turn off power to unit Check that all wires are connected Motor has stopped operating Replace motor 2 Fan is operating but air moves slower than normal Obstruction in the exhaust ducting Check for any obstructions in the ducting The most common are bird nests in the roof cap or wall cap where the fan exhausts to the outside Speed control not set high enough If a speed control is being used confirm the setting Incorrect wiring Turn off power to unit Check that all wires are connected correctly 3 Fan is operating
14. ed sont garantis pour un an partir de la date d achat contre les d fauts de main d uvre et ou de mat riel De plus tous les ventilateurs vacuateurs chaufferettes combin s ventilateur lumi re et ou les chaufferettes et les hottes de cuisine sont garantis pour cing ann es partir de la date d achat contre les d fauts de main d uvre et ou de mat riel Cette garantie ne couvre pas de co ts de transport ou de main d uvre ou le co t de remplacement de composantes faisant partie d entretien de routine tels que Filtres graisse des hottes de cuisine filtres au charbon ou combin filtre graisse charbon ampoules lectriques de remplacement dans les hottes de cuisine ou les combin s ventilateur lumi re chaufferette pour salle de bain Aussi tout dommage ou d faillance caus par un abus une mauvaise utilisation une installation fautive ou un entretien incorrect ne sera pas couvert par cette garantie De mani re effectuer une r clamation sous cette garantie vous devez tre l acheteur original du produit Il vous sera exig de pr senter la facture d achat originale Air King qui d montrera La date d achat l endroit de l achat et le mod le achet Le manquement rencontrer ces exigences annulera votre garantie Air King ne sera pas tenu responsable de quelque blessure corporelle ou dommage la propri t ou l immeuble que ce soit caus directement ou indirectement par le produit Certains tats n
15. et AIF8X AIF10X 587635034 Grommet 5S7699020 Screw 557699024 5587635036 New 9 06 WWW AIRKINGLIMITED COM Grill Spring 5S7635028 6 of 12 INSTRUCTIONS IMPORTANTES MANUEL D OPERATION Mod les AIK14X AIK16X AIK24Y AIK26Y e gt 14 AIF4X AIF6Y AIF8X AIF10X HinKing Ventilateur d vacuation AIG4 AIG6 Ventilation Products mE en serie LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D ASSEMBLER INSTALLER OPERER OU DE R PARER LE PRODUIT D CRIT PROT GEZ VOUS M ME ET LES AUTRES EN OBSERVANT TOUTE L INFORMATION DE S CURIT FAILLIR SE CONFORMER AUX INSTRUCTIONS PEUT R SULTER EN BLESSURE PERSONNELLE GRAVE ET OU EN DOMMAGE LA PROPRI T CONSERVER CES INSTRUCTIONS POUR R F RENCES FUTURES INSTRUCTIONS G N RALES DE S CURIT Lors de l utilisation d appareils lectriques des pr cautions de base doivent toujours tre suivies pour r duire les risques d incendie de choc lectrique et de blessures corporelles incluant ce qui suit AVERTISSEMENT NE PAS BRANCHER L ALIMENTATION AVERTISSEMENT POUR USAGE DE VENTILATION AVANT QUE LE VENTILATEUR NE SOIT COMPLETEMENT GENERALE EXCLUSIVEMENT NE PAS UTILISER POUR EVACUER INSTALLE ASSUREZ VOUS QUE LE SERVICE LECTRIQUE SUR DU MATERIEL ET DES VAPEURS DANGEREUSES OU EXPLOSIVES LE VENTILATEUR EST VERROUILLE A LA POSITION ETEINTE 6 Lors de coupe ou de per age des murs et plafonds ne pas 1
16. ications where ducting passes through unconditioned space or where noise is a factor Failure to use insulation could result in excessive condensation buildup within the duct and undesirable sound levels within the room Duct runs should have as few bends as possible NOTE Flexible insulated ducting may be used where allowed by local code For the quietest possible installations it is recommended a minimum of 8 of insulated flexduct be used between any exhaust grill and fan When using flexible type duct work duct should be stretched as tight and straight as possible Failure to do so could result in dramatic loss of system performance Flexible duct should be connected to the fan with screw clamps or duct tape All connections should be as airtight as possible to maximize system performance 1 Connect one end of the ducting not included to the room level collar damper and the other end to the Y transition Secure both ends in place using tape or a screw clamp to create as air tight a seal as possible Repeat this step for the other room level grill housing Figure 7 Exhaust to Wall Roof Cap Y Transition N Ducting Collar Damper T Figure 7 NOTE Units that include only one collar do not utilize the Y transition Follow the same instructions as in step 1 except connect the one end of the ducting directly to
17. izontale s av re n cessaire et que l accumulation de condensation pourrait occasionner un probl me enveloppez le ventilateur d isolant afin d en minimiser l accumulation 2 Fixezle ventilateur au support de montage en utilisant les trois vis t le de 1 11 mm incluses en vous assurant que la bo te de c blage soit facilement accessible Figure 2 5S7635036 New 9 06 Support REMARQUE Le support est muni de passe c bles isol s en caoutchouc pour la vibration afin d emp cher la transmission du son par le truchement de la structure Prenez soin de ne pas trop serrer De plus assurez vous de ne pas d nuder la gaine de plastique Les vis sont autotaraudeuses et ne requi rent pas d avant trous Cependant des avant trous n exc dant pas 1 52 mm peuvent tre utilis s afin de faciliter l installation SECTION 3 Installation de la grille d chappement d arriv e 1 Choisissez la ferrure d attache au sein du secteur tre ventil qui ne g ne pas une solive de plafond Afin de faciliter l installation l emplacement des poutres entre les murs ou les solives qui supportent le plafond devrait tre pris en compte Des collets clapets sont inclus avec une courroie perfor e de suspension pour fixer directement sur une poutre ou une solive Assurez vous de laisser suffisamment d espace entre le collet clapet et la poutre pour fixer le syst me de conduit Si l emplacement de la gri
18. lle ne permet pas de la fixer directement une traverse fix e au b ti devrait tre utilis e 2 Pliezles courroies de montage fix es au collet vers l ext rieur de sorte qu elles soient situ es juste en face Figure 3 Courroie de montage Courroie de montage Collet clapet Figure 3 SECTION 4 Nouvelle construction 1 Installez le collet clapet dans l emplacement choisi en fixant les vis bois de 25 40 mm incluses dans la courroie de montage La hauteur de l installation est d termin e par l paisseur finale du mat riel du mur ou du plafond Assurez vous que le bord du collet clapet soit au m me niveau que le mat riel du mur ou du plafond final Figure 4 WWW AIRKINGLIMITED COM 8 of 12 Montant Solive Collet clapet Collet clapet is Figure 4 Mat riel du mur plafond 2 Une fois le mat riel du mur plafond en place installez la grille dans le collet en la poussant fermement vers le collet jusqu ce qu elle soit effleurement du mat riau du mur plafond Figure 5 Grille SECTION 5 Construction Existante 1 Placez le collet clapet l emplacement choisi et tracez un cercle sur la surface A partir du c t int rieur de la pi ce coupez au travers de la surface Veuillez noter Prenez soin de ne pas endommager le plafond et faites une coupe lisse Figure 6 2 Placezle collet clapet dans l ouverture d coup e de
19. louder than normal Motor is loose 3a Turn off power to unit Confirm unit is mounted securely to bracket Restore power to unit Fan mounting screws too tight 3b Turn off power to the unit Loosen screws going through rubber grommets Fan damaged in shipping 3c Contact seller for replacement LIMITED WARRANTY All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and or material In addition all ventilating exhaust fans heaters combination fan lights and or heaters and range hoods are guaranteed for five years from the date of purchase against defects in workmanship and or material This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance such as range hood grease filters charcoal filters or combination charcoal grease filters replacement light bulbs in range hoods or bathroom fan light bulb heater combinations As well any damage or failure caused by abuse misuse abnormal usage faulty installation or improper maintenance will not be covered by this warranty In order to make a claim on this warranty you must be the original consumer of the product You will be required to present to Air King the original bill of sale showing date of purchase place of purchase and model purchased Failure to meet these requirements will void your warranty Air King will not be held resp
20. mper in the selected location using the provided 1 wood screws through the mounting strap The mounting height is determined by the thickness of the final wall ceiling material Ensure that the edge of the collar damper will be flush with the finished wall ceiling material Figure 4 WWW AIRKINGLIMITED COM 2 of 12 Joist Stud Va Collar Damper Collar Damper 4 lp Figure 4 Wall Ceiling Material 2 Once the wall ceiling material is in place install the grill into the collar by pushing it firmly inward towards the collar until it fits flush against the wall ceiling material Figure 5 SECTION 5 Existing Construction 1 Place the collar damper in the selected location and trace a circle onto the surface From the interior side of the room cut through the surface Please note Take care not to damage the ceiling and make a smooth cut Figure 6 2 Position the collar damper in the previously cut hole so that itis flush with the finished ceiling and secure to the joist stud using the provided 1 wood screws through the mounting strap Figure 4 3 Install the grill into the collar by pushing it firmly inward towards the collar until it fits flush against the wall ceiling material Figure 5 5S7635036 New 9 06 SECTION 6 Ducting CAUTION ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES NOTE Insulated ducting is required for bathroom exhaust appl
21. ntilateur les crit res suivants doivent tre pris en compte a Installation visant r duire le bruit g n r par le fonctionnement du ventilateur L installation du ventilateur aussi loin que possible du point d entr e emp chera en partie le bruit de son fonctionnement d tre retransmis par le truchement du syst me de conduits S il est utilis comme ventilateur de renfort pour assurer la distribution d air entre deux pi ces un point central au long du syst me de conduit pourrait s av rer optimal Un syst me de conduit flexible isol recommand pour toutes les installations de ventilateurs dans les salles de bain procurera un fonctionnement beaucoup plus silencieux Il est recommand d utiliser au moins 2 44 m de gaine flexible entre toute grille d chappement etle ventilateur pour minimiser le niveau de bruit b Accessibilit pour l entretien L emplacement du ventilateur devrait pr voir un acc s suffisant pour l entretien SECTION 2 Installation du ventilateur 1 En vous servant des vis bois de 25 mm incluses fixez le support de montage un montant de support l emplacement choisi Figure 1 Installation horizontale Installation verticale REMARQUE Le ventilateur peut tre install l emplacement de votre choix le long du conduit cependant une installation verticale est recommand e afin de minimiser l accumulation de condensation dans l unit Dans le cas o une installation hor
22. onduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les normes de s curit telles 13 NE JAMAIS placer un interrupteur un endroit qui puisse que celles publi es par la National Fire Protection Association tre atteint de la baignoire ou de la douche NFPA et de la American Society for Heating Refrigeration 14 Ne pas ins rer les doigts ou tout corps tranger dans le moteur and Air Conditioning Engineers ASHRAE et de celles des autorit s locales du code AVERTISSEMENT NEPASUTILISER DANS LES CUISINES 10 Peut tre utilis avec r glage de vitesse a semi conducteurs 11 Cette unit comprend des parties rotatives Des mesures de s curit devraient donc tre prises pendant son installation son fonctionnement et son entretien 12 Des gardes protectrices doivent tre install es lorsqu il est la port e du personnel ou l int rieur de 2 13 m d un niveau de travail ou lorsque cette mesure s av re n cessaire pour assurer la s curit CONSERVER CES INSTRUCTIONS 5S7635036 New 9 06 WWW AIRKINGLIMITED COM 70712 INSTRUCTIONS D INSTALLATION AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION SECTION 1 Pr paration en pr vision de l installation du ventilateur 1 Lorsque vous choisissez l emplacement pour l installation du ve
23. onsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts so these exclusions or limitations may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province FOR PARTS OR TECHNICAL ASSISTANCE Please call 1 800 465 7300 MONDAY THROUGH FRIDAY BETWEEN THE HOURS OF 8 AM AND 4 00 PM EST PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE Reference the type and style of product located on label inside of the product when you call For more information please visit our website wwwairkinglimited com Installer Installation Date Place of Purchase Model Number 5S7635036 New 9 06 WWW AIRKINGLIMITED COM Sof 12 REPLACEMENT PARTS DIAGRAM TIITII ITITI op ofo N Single Inlet Fan Kit Replacement Parts Description Replacement Part Description Replacement Part Motor AIK14X 587635000 Motor AIK24Y 557635000 Motor AIK16X 587635001 Motor AIK26Y 557635002 Cover Plate AIK14X 5S7635029 Cover Plate AIK24Y 557635029 Cover Plate AIK16X 587635030 Cover Pl
24. rendement du syst me Le conduit flexible devrait tre rattach au ventilateur l aide de serre joints ou de ruban conduits Toutes les connexions devraient tre aussi tanches que possible afin de maximiser le rendement du syst me 1 Raccordez une extr mit du conduit non inclus au collet clapet au niveau de la pi ce et l autre extr mit a l embranchement en Y Fixez les deux extr mit s en place en utilisant du ruban ou un serre joint afin de cr er un joint aussi tanche que possible R p tez cette tape pour le ch ssis de la grille de l autre pi ce Figure 7 Evacuation vers le capuchon du mur plafond 1 Ventilateur Embranchement en si Y LLA bs Conduit E amp E Collet clapet Z Figure 7 REMARQUE Les unit s qui incluent un seul collet n ont pas besoin d embranchement en Y Suivez les m mes directives qu l tape 1 sauf que vous raccordez l extr mit du conduit directement au ventilateur 2 Raccordez une extr mit du conduit la partie sup rieure de l embranchement en Y et l autre extr mit la prise d entr e du ventilateur Figure 7 3 Raccordez une extr mit du conduit l vacuation du ventilateur et l autre extr mit un capuchon de mur ou de plafond Figure 7 Toujours canaliser le ventilateur vers
25. rez l aide d un petit tournevis r gulier Ins rez le fil noir partir du commutateur mural dans le port de la plaquette de connexions tiquet L et serrez l aide d un petit tournevis r gulier Etant donn que le moteur est isol au sein d un bo tier de plastique il n est pas n cessaire de proc der une mise la terre Figure 10 Alimentation provenant de la maison 4 Assurez vous que toutes les connexions de c blage sont fix es de mani re s curitaire la plaquette de connexions et replacez le couvercle du bo tier de raccordement 5 R tablissez le courant et testez votre installation SECTION 9 Utilisation et entretien AVERTISSEMENT ASSUREZ VOUS QUE LE COURANT EST COUPE A PARTIR DU PANNEAU ELECTRIQUE AVANT DE PROCEDER A L ENTRETIEN DE LUNITE 1 Nettoyage de la grille Retirez la grille et nettoyez la l aide d un d tergent doux comme du savon vaisselle et s chez l ensuite avec un chiffon doux NE JAMAIS UTILISER DE TAMPONS ABRASIFS OU DE POUDRES A RECURER Ass chez la grille compl tement avant de la r installer Reportez vous aux instructions l tape 2 de la Section 4 pour r installer la grille 2 Les roulements du ventilateur sont scell s et munis d un mat riel lubrifiant interne aucune lubrification additionnelle n est requise 10 of 12 Guide de d pannage Cause Possible Solution Sugg r e 1 Le ventilateur ne fonctionne pas lorsque Un fusibl
26. sorte qu il soit effleurement du plafond final et fixez le la solive au montant en ins rant les vis bois de 25 40 mm incluses au travers de la courroie de montage Figure 4 3 Installez la grille dans le collet en la poussant fermement vers le collet jusqu ce qu elle soit effleurement du mat riau du mur plafond Figure 5 SECTION 6 Conduit AVERTISSEMENT TOUS LES CONDUITS DOIVENT TRE CONFORMES AVEC LES CODES DU BATIMENT LOCAUX ET NATIONAUX 5S7635036 New 9 06 REMARQUE Un conduit isol est requis pour les installations d vacuations de salles de bain lorsque le conduit passe par un emplacement non climatis ou dans un emplacement o le bruit repr sente un facteur important Le fait de ne pas utiliser d isolant pourrait entra ner une accumulation excessive de condensation au sein du conduit de m me qu un niveau de sonorit ind sirable dans la pi ce Les courses de conduits devraient pr senter aussi peu de coudes que possible REMARQUE Des conduits isol s flexibles peuvent tre utilis s l o le code local le permet Pour des installations au niveau de sonorit le plus bas possible il est recommand d utiliser au moins 2 44 m de conduit flexible entre toute grille d chappement et ventilateur Lors de l utilisation de syst mes de conduit de type flexible le conduit devrait tre tir aussi serr et droit que possible Le cas contraire pourrait entra ner une baisse dramatique de
27. te l crou oreille dans l arbre Figure 8 Ecrou oreille Poign e Rondelle lt 1 Embranchement en si Y mw Figure 8 4 Ajustez le clapet de sorte a quilibrer le d bit d air et serrez l crou oreille pour le fixer en place SECTION 8 C blage du ventilateur AVERTISSEMENT VOUS ASSURER QUE L ALIMENTATION EST COUPEE AU PANNEAU DE SERVICE AVANT DE COMMENCER L INSTALLATION AVERTISSEMENT TOUTES LES CONNEXIONS DOIVENT TRE FAITES EN CONFORMIT AVEC LES CODES LECTRIQUES LOCAUX OU NATIONAUX SI VOUS N TES PAS FAMILIER AVEC LES M THODES D INSTALLATION DE C BLAGE LECTRIQUE RECOURREZ AUX SERVICES D UN LECTRICIEN QUALIFI 1 Retirez les vis de la plaque du couvercle de la bo te de raccordement situ e sur le c t du moteur Figure 9 5S7635036 New 9 06 WWW AIRKINGLIMITED COM Bo te de raccordement 2 Passez le c blage d un calibre appropri partir d un commutateur mural approuv Un fil de connexion de neutre blanc et un fil de vivant fil noir branch au commutateur Fixez les fils lectriques au bo tier avec un connecteur lectrique approuv Assurez vous de laisser suffisamment de c blage dans le bo tier de raccordement afin de pouvoir effectuer les branchements la plaquette de connexions lectriques pr cabl e du ventilateur 3 Ins rez le fil blanc provenant de la maison dans le port de la plaquette de connexions tiquet N et ser
28. the fan 2 Connect one end of the ducting to the top of the Y transition and the other end to the intake of the fan Figure 7 3 Connect one end of the ducting to the exhaust of the fan and the other end to a wall or ceiling cap Figure 7 Always duct the fan to the outside through a wall or roof cap WWW AIRKINGLIMITED COM 3 of 12 NOTE When using insulated flex duct it is recommended that the inner vinyl core be screw clamped or taped to the inlet and outlet and that the vapor barrier surrounding the insulation be taped to the fan housing NOTE When attaching flex duct to the collar damper combination and an immediate elbow is necessary be certain that the elbow is installed with a soft bend to allow damper blades to operate properly SECTION 7 Installing Optional Balancing Damper Some kits include an optional balancing damper to allow for adjustment of the system The damper may be used where the grills will be connected using branches of unequal length or where the flow will need to be balanced for any reason To Install the optional damper 1 The damper must be installed on the branch with the least restriction This is generally the duct that is shortest or has the fewest bends 2 Drill a 5 16 hole approximately 1 1 2 from the edge on the flat side of the Y transition 3 _Insertthe shaft of the damper into the hole drilled in step 2 Place the washer handle then wing nut onto the shaft Figure