Home

Aiphone RY-3DL User's Manual

image

Contents

1. 9 KB DAR al a9 re a Tai inlet Knock out hole on top or bottom when surface running the cable a Front screw Notes Do not connect on b1 b3 of RY 3DL FEATURES e Selective door release with one button Door release contacts release the door where communication is established e Works with three different systems KB 3MRD MK 2MCD amp IE 2AD U e Normally open contacts for electric door strikes e Normally closed contacts for magnetic locks if corresponding door station is not used e 10 pin connector for CN12 is supplied with KB 3MRD AN Cut and insulate all the unused wires PS 2420 Li L2 L3 N C side of contact Sas 4 WIRING DIAGRAMS e MK 2MCD system with 2 door releases IE 2AD U with 2 door releases Pantilt door stations IE IF door stations Master Sub Sub Master IF DA IE 2AD U IEH 1CD IEH 1CD Sub MK DBC MK 2MCO MK 2HCD 2 RY 3DL e Terminal b3 remains unused e Powered by PS 1820 of system pera S pin connector 7 L2 L3 N C side of contact I CNG is located inside the unit 7 PS 1225 or AC trans 12V 16V AC A Cut off and insulate all the unused wires 7 TECHNICAL PRECAUTIONS e Do not remove rubber cover on front panel as inside components 5 MOUNTING _ will be exposed e Do not use any unused terminals for any other purpose e Do not attempt to connect two door releases to a single cont
2. 830674 0204 O P AIPHONE DOOR RELEASE ADAPTOR Model RY 3DL INSTALLATION amp OPERATION MANUAL 1 SYSTEM OUTLINE amp COMPONENTS The RY 3DL provides selective door release capability with the KB 83MRD Video Sentry Color Tilt MK 2MCD Video Sentry PanTilt Plus or IE 2AD U Chime Tone Intercom Normally Open and Normally Closed outputs are available PACKAGE CONTENTS e Door release adaptor RY 3DL e 6 pin connector for MK 2MCD Door release l j e Packet of screws EL 9S a e Installation amp Operation Manual Hras j i RF Sa ae TES N TO p d SYSTEM COMPONENTS KB 3MRD Color video system w 3 door releases Power supply PS 2420 MK 2MCD PanTilt video system w 2 door releases Power supply PS 1820 IE 2AD U Chime tone intercom w 2 door releases Power supply PS 1225 RY 3DL 3 Door release adaptor Powered by system power supply EL 9S RY 3DL KB 3MRD MK 2MCD IE 2AD U EL 9S Door release AC 12V 0 35A Powered by Refer to the Installation Manual packed with each master station AC transformer PT 1210N in USA or KVF in Europe 2 NAMES amp FEATURES 3 WIRING DIAGRAMS RY 3DL e KB 3MRD system with 3 door releases Kea Master Sub Sub Sub Sub sal 7 3 KB SMRD KB 3HRD KB 3HRD KB 3HAD KB 3HRD Cable inlet E gt a 2 R A EL as jh 3 a U Y Do not open the cover Single gang chassis with terminal blocks al KB DAR S
3. ranty covers bench repairs only and any repairs must be made at the shop or place designated in writing by Aiphone Aiphone will not be responsible for any costs incurred involving on site service calls ofe he eto efo whe ofe ofo ate ote ofe ofe eje ofe ofo ate fo ofo efe aje sfe efe afe eje afo ofa afe ole abe of ee efe efe efe opo ofo sjo cfo efa fe efe opo efe ofe efe fe spo ofe ede jo efo ele vfo of ofe ote ofe efo ofe sje oje efe oje of fe ofe AIPHONE CO LTD NAGOYA JAPAN AIPHONE CORPORATION BELLEVUE WA USA 3 Al PHO N E AIPHONE EUROPE N V ANTWERP BELGIUM A Providing Peace of Mind http www aiphone com 2 Printed in Japan E Sette ttees
4. rol terminal Ln Cn n 1 3 e When RY 3DL is mounted below master station the image may slightly vary at release of door release button Keep RY 3DL at least 10m 33 away from master station e When IE 2AD U does not have door station 2 or 1 connected eliminate use of door release 2 or 1 by disconnecting D2 or D1 terminal between RY 3DL and IE 2AD U Cleaning Clean the RY 3DL unit with a soft cloth dampened with neutral household cleanser Do not use any harsh cleaner or cloth AC Trans AC Trans L1 L2 L3 N C side of contact EB Fr Front screw Sa Screw 2 supplied 8 SPECIFICATIONS Ne e Power source 12 24V DC 30mA or 12 16V AC 60mA supplied from System s power supply PS 2420 1 Loosen front screw attached KB 3MRD s PS 1820 MK 2MCD 2 Disconnect and separate RY 3DL from chassis S 1225 or AC trans IE 2AD U 3 Attach the chassis to single gang box or directly e Relay contacts N O or N C output 1A at 50V AC 1A at 30V DC to wall surface For other types use a matching relay 4 Terminate wires on screw terminals and splice e Wiring 4 wires between KB 3MRD amp RY 3DL with wires from the master station 3 wires between MK 2MCD amp RY 3DL 4 wires between IE 2AD U amp RY 3DL 2 wires to each door release 6 OPERATIONS e Wiring distance 22AWG 18AWG the single door release button on the intercom will Master to RY 3DL _50m_ 100m 165 330 acti
5. vate the door release mechanism associated with RY 3DL EL 9S that door The adaptor can be installed with the power The distance secured may vary when using door release supplies for the system e Dimensions 140H x 74W x 42D mm 5 1 2 H x 3 W x 1 1 2 D e Weight Approx 200g 0 44lbs che e oe oe ete oe tea oe ote oe be ae he oe abe oe ae ake ae oe ake oe of ae feat ooo oe ebe oe af oe ete ob be ob oe be oe oe ok oe otro a oe of oe of ob af oe oe of oe abe oe abe ae vos oe When communication is established to a door station WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service k fora penoa of one year after delivery to the ultimate user and will repair free of charge or replace at no charge sb 3 should it become defective upon which examination shall disclose to be defective and under warranty Aiphone ps reserves unto itself the sole right to make the final decision whether thre is a defect in materials and or s workmanship and whether or not the product is within the warranty f This warranty shall not apply to any Aiphone product which has been subject to misuse neglect accident or to in violation of instructions furnished nor extended to units which have been repaired or altered outside of the factory This warranty does not cover batteries or damage caused by batteries used in connection with the product This war