Home
Aiphone IC-1AD User's Manual
Contents
1. Momentarilly depress CALL button After room station replies talk handsfree adg At room station Incoming call is announced by 4 stroke chime at IC 1AD U and ICR 1 if installed To reply simply pick up handset at IC 1AD U After communication hang up handset onto its cradle properly TPE sic 2 To operate door release vf While you hold your handset depress and hold door release button on IC 1 AD U E MEDIUM The visitor may open the door while buzzing sound is heard r 3 Adjusting chime volume LOW Adjust chime call volume to 3 levels as desired by the switch on IC 1AD U while chime call volume at ICR 1 remains unchanged WARRANTY amp Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one E year after delivery to the ultimate user and will repair free of charge or replace at no charge should it become defective upon which examination shall disclose to be defective and under warranty Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and or workmanship and whether or not the product is within the warranty This warranty shall not apply to any Aiphone product which has been subject to misuse neglect accident or to use in violation of instructions furnished nor extended to units which have been repaired or altered outside of the factory This warranty does no
2. lt gt AIPHONE 830515 0787 CHIME 1 1 AC DC CHIME TONE INTERCOM TYPE 1 DOOR 1 ROOM MODEL IC 1AD U 4C12 16V 50 60Hz or DC12 24V INSTRUCTIONS DIMENSIONS UNIT mm inch Chime volume control Door release button IC 1AD U SOs 3 1 87 FEATURES Simultaneous communication system for 1 each door station room station and door release Can be powered by a single bell transformer for both communication and door release May be combined with MC D MC U Video Intercom System hanging up handset shuts off video monitor Melodic 4 stroke chime with volume control Call extension device to announce a chime call from any door in a place remote from room station Select a most suitable door station from IC series door stations SPECIFICATIONS Power source IC IAD U May be powered by a bell transformer AC12 16V 135 mA or more OR a power supply DC12 24V 150 mA or more Current consumption 135 mA maximum AC12 16V 150 mA maximum DC12 24V Wiring and communication distance Single pair of wires Select the proper wire gauge to meet your requirements from the chart below Diameter of wires 0 5 mm 0 65 mm 0 8 mm 1 0 mm AWG 24 AWG 22 AWG 20 AWG 18 AWG Distance 90m w0 s0 750 _ 1 180 Door release Use a door release EL 9S AC12V 250 mA or of other manufacture which does not exceed AC12 16V 500 mA when powered by a system s bell transformer Bell tr
3. Terminals with the supplied screws Insert the prongs of the Onego box bracket into the holes of the body and pull the body ie a downward ta he Part TES an a Be careful not to attach the bracket upside down all 30 lt 8 Pe rie N 35 16 IJ se the MARK 6 for easier insersion al m a oe Sy Screw X2 E Wires for Wires for communication power supply WIRING DIAGRAM ROOM STATION IC 1AD U BELL TRANSFORMER Not supplied by AIPHONE AC12 16V 450mA or more CALL EXTENSION WHITE wire NON POLARIZED NOTES 1 Door station Wiring is non polarized Connect either terminal or on IC 1 AD V to either terminal or on door station 2 Door release As shown in the above diagram EL 9S can be powered by a system bell transformer 3 Call extension Wiring is non polarized Extend one pair of wires from ICR 1 and connect each to either WHITE wire on IC 1AD U 4 Bell transformer It is suggested that the bell transformer should be located close to the IC 1 AD U station Connect either output wire on bell transformer AC 2 16V to either terminal or on IC 1AD U Note When using a power supply DC12 24V observe polarity carefully en See OPERATIONS Room station Door station poe CALLING Dina t l ES p a _ DING DONG tili RI ii mm meee ee ee DOOR RELEASE 1 Communication At door station
4. ansformer for both communication and door release AC12 16V 450 mA or more for EL 98S AC12 16V 700 mA or more for other manufacture s BEFORE YOU INSTALL AND OPERATE THE EQUIPMENT Prohibitions and precautions Operation 1 DO NOT HOLD HOOK SWITCH DOWN WHILE PICKING UP HANDSET THE CHIME NEVER TONE SOUNDS THRU THE HANDSET RECEIVER ELEMENT AND COULD CAUSE HEARING DAMAGE Installation 1 DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES When you mount IC 1 AD U in place of existing bell or chime be sure to disconnect wires from the present transformer 2 Be sure to disconnect wires from bell transformer or power supply before you open the IC 1AD U unit or make wiring connections 3 Avoid running the connecting wires thru doors windows or between furniture which may pinch and disconnect the wires 4 IC 1AD U equipment must be installed in as dry and dust free environment as possible Maintenance l Clean your IC 1AD U equipment with a soft cloth dampened with neutral household cleanser Never use thinner nor benzine etc 2 Do not splash water on the door station by hose etc as pe x X X amp i SYSTEM LAYOUT Room station Call extension Door release EL 9S SUB BELL TRANSFORMER AC12 16V 450 mA A SINGLE BELL TRANSFORMER CAN SUPPLY POWER FOR BOTH COMMUNICATION AND DOOR RELEASE EL 9S COMPONENTS AVAILABLE Door stations Select either type fr
5. om the IC series door stations Announces a call from door by chime in a place remote from IC 1 AD U one per system IC 1AD U BACK VIEW 4 i 2 For power supply Connect to terminals on door station non polarized eee Ha Connect to electric door release or DC12 24V non polarized 1 Ce rrn L WHITE wire For call extension non polarized WHITE wire 3 Connect 2 wires to the wires from the ICR 1 non polarized se IC DC w plastic cover IC JA w stainless steel cover Flush mount Surface mount F Y lumi IC NA w plastic cover IC FY w aluminum cover Flush mount Semi flush mount IC RA w brown metal cover Semi flush mount IC DA R w plastic cover IC KA w brown metal cover Surface mount Semi flush mount ICR 1 Call extension EL 9S CASE amp CHASSIS IC D1 IC DL1 1 call IC D2 IC DL2 2 call IC D3 IC DL3 3 call IC D2 DL2 w anodized aluminum cover Surface mount i IC DL type with illumina iC D3 DL3 tion lamp Electric door release AC12V 250mA May be powered by a system s bell transformer one per system INSIDE VIEW 1 Remove 2 screws on back of the chassis and separate front case and chassis 2 As shown take out two WHITE wires thru a hole on the chassis WALL MOUNTING INSTALLATION Ic ADIU Mounting bracket Attach the mounting bracket to wall or one gang box
6. t cover batteries or damage caused by batteries used in connection with the product This warranty covers bench repairs only and any repairs must be made at the shop or place designated in writing by Aiphone Aiphone will not be responsible for any costs incurred involving on site service calls Aiphone Co Ltd Nagoya Japan Aiphone Corporation Bellevue Washington IC 1AD U INSTRUCTIONS E SS INTERCOM SYSTEMS gt Al PHONE HOME BUSINESS INDUSTRY Printed in Japan