Home

Tripp Lite SmartOnline 120kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS

image

Contents

1. Replacement Description By authorized service technician VOLTAGE REGULATION Voltage Regulation Description Online double conversion power conditioning Maintains continuous operation without using battery power during overvoltages to 276 477 3 phase 4 wire wye Overvoltaga Correction reducing output within 1 of nominal Maintains continuous operation without using battery power during brownout undervoltage conditions to 173 300 Undervoltage Correction 3 phase 4 wire wye USER INTERFACE ALERTS amp CONTROLS ON button turns UPS inverter on OFF button turns UPS inverter off LCD Display Control Buttons browse through Switches and select items displayed on LCD screen EPO Emergency Power Off button turns UPS output off and disables Bypass output Alarm Cancel Operation Power fail alarm can be silenced using alarm cancel switch Audible Alarm Alarms signal a variety of operational conditions low battery overload shutdown bypass and more LED Indicators 4 LED Display Displays normal AC input on battery power bypass input and fault conditions SURGE NOISE SUPPRESSION UPS AC Suppression Joule Rating 5960 UPS AC Suppression Response Instantaneous Time EMI RFI AC Noise Suppression PHYSICAL Installation Form Factors Supported Tower with Included Accessories UPS Power Module Dimensions 66 8 x 20 5 x 38 4 hwd in 3 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234
2. www tripplite com UPS Power Module Dimensions 169 7 x 52 1 x 97 5 hwd cm UPS Power Module Weight Ibs 835 3 UPS Power Module Weight kg 379 2 UPS Shipping Dimensions hwd in 76 1 x 28 5 x 48 2 UPS Shipping Dimensions hwd 193 3 x 193 3 x 122 4 cm i g ENVIRONMENTAL Op COMMUNICATIONS Communications Interface DB9 Serial EPO emergency power off Slot for SNMP Web interface Included Communications Cable DB9 cabling included LINE BATTERY TRANSFER Transfer Time No transfer time 0 ms in online double conversion mode Storage Temperature Range Relative Humidity PowerAlert Software Low Voltage Transfer to Battery Power Setpoint High Voltage Transfer to Battery Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode During a Power Failure High Availability UPS Features Green Energy Saving Features CERTIFICATIONS UPS Certifications Maintains continuous operation without using battery power during brownout undervoltage conditions to 173 300V AC 3 phase 4 wire wye Below this point output is maintained utilizing reserve battery power Maintains continuous operation without using battery power during overvoltages to 276 477V AC 3 phase 4 wire wye reducing output within 1 of nominal Above this point output is maintained utilizing reserve battery power Cold start operation supported Automatic inverter bypass High efficiency economy mode operation Schedula
3. LED display includes a real time event log screen with up to 500 events listed e Dynamic battery management screen optimizes battery function to lengthen service life and allow cold restart of the UPS e Built in RS 232 communication port works with included PowerAlert Software to provide shutdown commands and reporting on a single server e Accessory slot accepts an optional internal SNMPWEBCARD and MODBUSCARD accessory options e Emergency Power Off button turns UPS output OFF and disables Bypass output e Built in Emergency Power Off EPO dry contact interface supports remote emergency shutdown in large facilities Specifications General Info OUTPUT SE a Nominal Output Voitage s 220 380V 230 400V 240 415V 3 Phase Wye Supported Nominal Voltage Details Less than 3 output THD Frequency Compatibility 50 60 Hz Output Voltage Regulation Line 1 Mode Output Voltage Regulation Battery 4 40 Mode INPUT 2 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com 3 Phase Wye 4 wire L1 L2 L3 N G Less than 4 input harmonic distortion THD BATTERY Expandable Battery Runtime Battery set sold separate External Battery Pack Compatibility BP480V103 BP480V140 BP480V55 BP480V78 BP480V200 BP480V300 BP480V400 BP480V500 Expandable Runtime Description External battery pack wiring is contractor supplied DC System Voltage VDC 240VDC Battery
4. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 120kVA Modular 3 Phase UPS System Highlights On line Double Conversion International UPS E a I eas eae on line double conversion 3 MODEL NUMBER SU120KX2 phase UPS e 3 phase 220 380V 230 400V 240 415V 4 wire ground wye input amp output e Scalable modular N 1 redundant architecture helps assure 100 availability e Parallel up to 4 UPS systems for redundancy or increased capacity e IGBT amp DSP technology produce lt 4 input harmonic distiortion THDi e Hot swappable power modules Expandable runtime Package Includes e SU120KX2 UPS System e PowerAlert Software e Parallel communication cable Description Tripp Lite SU120KX2 120kVA SmartOnline Modular 3 Phase Intelligent True On Line Double Conversion UPS System provides 100 system availability with N 1 modular architecture and parallel capability In N 1 configurations SU120KX2 provides 6 self contained redundant 20kVA power modules that support 2 r ee e Instruction manual hot swappable maintenance while connected equipment remains powered In parallel applications configured and installed by a Tripp Lite authorized technician up to 4 SU120KX2 models can be connected to provide s Maranty information fail safe redundancy two 120kVA models supporting up to 120kVA or increased capacity two 120kVA models supporting up to 240kVA Larg
5. ble daily hours of economy mode operation CE 4 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com WARRANTY Product Warranty Period 2 year limited warranty International Product Warranty Period Mexico 2 year limited warranty ihe Warranty Period Puerto 2 year limited warranty 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 5 5
6. e capacity 120 000VA 96 000W UPS continually converts incoming AC power into filtered DC and resynthesizes output into perfectly regulated continuous sine wave AC output with less than 3 THD Zero transfer time assures compatibility with all equipment types High input power factor advanced IGBT inverter and Digital Signal Processor DSP technology produce less than 4 input total harmonic distortion THDi With low THDi generators run cooler and last longer allowing managers to save installation costs by installing a generator with a capacity equal to the equipment load 1 1 ratio Up to 97 efficiency option reduces operating costs and BTU output Hardwire input and output connections support a variety of permanent or PDU power connections Frequency is 50 or 60 Hz auto selectable SU120KX2 power modules are housed in a single small footprint tower compartment Compatible battery pack models BP480V55 BP480V78 BP480V103 and BP480V 140 sold separately are housed in a separate stand alone hardwired external battery compartment Battery runtime can be extended with additional stand alone hardwired external battery modules A manual bypass breaker and an automatic bypass function ensure 100 availability of connected equipment by safely passing through AC power if the UPS requires maintenance Features e True On Line Double Conversion 120kVA 120 000VA 96kW 96 000 watt SmartOnline Modular 3 Phase Intelligent UPS provides 100 system availabili
7. ty e Scalable modular N 1 configurations support hot swap replacement of any of the six self contained 20kVA power modules while connected equipment remains powered e Parallel applications enable the connection of 2 3 or 4 SU120KX2 models in parallel to enable advanced configurations for fail safe redundancy increased capacity and combinations of the two all parallel installations must be performed by a Tripp Lite authorized technician e Full time sine wave output with less than 3 output THD e High input power factor advanced IGBT inverter technology and Digital Signal Processor DSP technology produce low input THD THDi 1 5 Tripp Lite 1111 W 35th Street 6 Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e Less than 4 input THD THDi reduces installation costs by allowing 1 1 generator sizing e Extremely efficient operation up to 97 saves energy and reduces BTU output e Maintains continuous operation with zero transfer time through blackouts voltage fluctuations and surges e Removes harmonic distortion electrical impulses frequency variations and other hard to solve power problems e Wide input voltage correction range 173 300V 276 477V AC e Precision 1 output voltage regulation e 4 available battery modules BP480V55 BP480V78 BP480V103 and BP480V140 are housed in a separate stand alone hardwired external battery compartment Battery modules sold separately e Front panel combination LCD

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 サーモスタット付シャワーバス水栓  Osaka 2  OKI Semiconductor ML86V7667 Preliminary  MANUAL DE INSTRUÇÕES Monitor de Movimento KMV  Guide de Prise en Main V2  Contenido de la caja  52037102 TECHWOOD(KS 9260 A+ Gn) KAPAK    Philips SHS3211  ライカ ST4020  

Copyright © All rights reserved.
Failed to retrieve file