1. 370VDC FREQUENCY RANGE 47 63Hz INPUT EFFICIENCY Typ 76 83 83 86 86 86 AC CURRENT Typ 1 2AI115VAC 1A 230VAC INRUSH CURRENT max COLD START 60A twidth 5257s measured at 50 Ipeak at 230VAC LEAKAGE CURRENT 0 25mA 240VAC OVERLOAD 110 150 rated output power PROTECTION Protection type Hiccup mode recovers automatically after fault condition is removed 5 75 6 75V 13 8 16 2V 17 25 20 25V 27 6 32 4V 41 4 48 6V 55 2 64 8V OVER VOLTAGE Protection type Shut down o p voltage re power on to recover WORKING TEMP 30 70 C Refer to Derating Curve WORKING HUMIDITY 20 90 RH non condensing ENVIRONMENT STORAGE TEMP HUMIDITY 40 80 C 10 95 RH TEMP COEFFICIENT 0 03 C 0 50 C VIBRATION 10 500Hz 2G 10min 1cycle period for 60min each along X Y Z axes SAFETY STANDARDS UL879 except for LPV 60 5 UL1310 except for LPV 60 5 CSA C22 2 No 207 M89 except for LPV 60 5 LPV 60 48 CAN CSA C22 2 No 223 M91 except for LPV 60 5 LPV 60 48 IP67 approved design refer to TUV EN60950 1 SAFETY amp WITHSTAND VOLTAGE I P O P 3KVAC EMC ISOLATION RESISTANCE P O P gt 100M Ohms 500VDC 25 C 70 RH EMC EMISSION Compliance to EN55022 CISPR22 Class B EN61000 3 2 Class A EN61000 3 3 EMC IMMUNITY Compliance to EN61000 4 2 3 4 5 6 8 11 EN55024 light industry level criteria A MTBF 732Khrs min MIL HDBK 217F 25 C OTHERS DIMENSION 162 5 42 5 32mm L W H PACKING 0 4Kg 32pcs 13 8Kg 0 56CUFT NOT
2. 8AWG WH Ky re ACIN Blue A rail 81 5 Ts UL1007 16AWG AC L Brown on Red ye x V Black 3 5 X T case Max Case Temperature E Recommend Mounting Direction n Lf E Block Diagram fosc 65KHz EMI FILTER POWER RECTIFIERS f iy I P o amp 8 RECTIFIERS iii FILTER i an T ore jH pmi T ae CONTROL 7 ezm O v P _ E Derating Curve E Static Characteristics 100 100 230VAC 4 80 60 40 LOAD 20 ii 115VAC 30 15 0 15 30 40 50 AMBIENT TEMPERATURE C LOAD 70 HORIZONTAL 90 4 80 4 60 4 50 4 40l 4 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE V 60Hz File Name LPV 60 SPEC 2012 12 26
3. ANA MEAN WELL 60W Single Output Switching Power Supply L PV 60 series E Features e Constant voltage design e Universal AC input Full range e Withstand 300VAC surge input for 5 seconds e Protections Short circuit Overload Over voltage Cooling by free air convection e Fully encapsulated with IP67 level Note 8 eS a e Fully isolated plastic case e Class I power unit no FG lt e Class 2 power unit Pass LPS e Suitable for LED lighting and moving sign applications Note 7 e 100 full load burn in test e Low cost high reliability 2 years warranty SPECIFICATION o LPS IP67 AAN eav on A except for 5V 48V C MODEL LPV 60 5 LPV 60 12 LPV 60 15 LPV 60 24 LPV 60 36 LPV 60 48 DC VOLTAGE 5V 12V 15V 24V 36V 48V RATED CURRENT 8A 5A 4A 2 5A 1 67A 1 25A CURRENT RANGE 0 8A 0 5A 0 4A 0 2 5A 0 1 67A 0 1 25A RATED POWER 40W 60W 60W 60W 60W 60W OUTPUT RIPPLE amp NOISE max Note 2 80mVp p 120mVp p 120mVp p 150mVp p 150mVp p 150mVp p VOLTAGE TOLERANCE Note 3 8 0 5 0 LINE REGULATION 1 0 LOAD REGULATION 6 0 2 0 SETUP RISE TIME Note 6 500ms 20ms 230VAC 500ms 20ms 115VAC at full load for 5 36V 500ms 30ms 230VAC 500ms 30ms 115VAC at full load for 48V HOLD UP TIME Typ 50ms 230VAC 16ms 115VAC at full load VOLTAGE RANGE Note 4 90 264VAC 127
4. E 1 All parameters NOT specially mentioned are measured at 230VAC input rated load and 25 C of ambient temperature 2 Ripple amp noise are measured at 20MHz of bandwidth by using a 12 twisted pair wire terminated with a 0 1uf amp 47uf parallel capacitor 3 Tolerance includes set up tolerance line regulation and load regulation 4 Derating may be needed under low input voltage Please check the static characteristics for more details 5 The power supply is considered as a component that will be operated in combination with final equipment Since EMC performance will be affected by the complete installation the final equipment manufacturers must re qualify EMC Directive on the complete installation again Length of set up time is measured at first cold start Turning ON OFF the power supply may lead to increase of the set up time The unit might not be suitable for lighting applications in EU countries Please check with your local authorities for the possible use of the unit Suitable for indoor use or outdoor use without direct sunlight exposure Please avoid immerse in the water over 30 minute ONO File Name LPV 60 SPEC 2012 12 26 MW MEAN WELL 60W Single Output Switching Power Supply L PV 60 series E Mecha nical Specification Case No 976A Unit mm 600 30 162 5 600 30 3 5 UL1015 1
Download Pdf Manuals
Related Search
Related Contents
Guía del usuario de la impresora láser Phaser 5500 Nostalgia Electrics ICMP400WD Use and Care Manual PowerDirector 9 descargue el archivo PDF MODE D`EMPLOI ATLASTOUR Plus/Planner 取扱説明書 Avaya (303125-C User's Manual Copyright © All rights reserved.
Failed to retrieve file