Home
Bosch ISC-PDL1-W18G motion detector
Contents
1. Draft Insect and Small Animal Immunity The sealed optic chamber provides immunity to drafts and insects reducing false alarms Small animal immunity reduces false alarms caused by animals less than 4 5 kg 10 Ib such as rodents Remote Self Test A remote self test initiates when the walk test input switches to its true state The alarm relay and alarm LED activate for four seconds following a successful test The trouble relay activates and the alarm LED flashes following a failed test Input Power Supervision When the power is lower than 8 V a low input power trouble condition activates the trouble relay and causes the LED to flash The trouble condition clears automatically when power reaches or exceeds 8 V Trouble Memory When the walk test input switches to its true state for less than two seconds LED flashes to indicate the most recent trouble condition If there is no trouble in memory the LED does not flash After twelve hours or after the detector receives a second walk test pulse for two seconds or less the LED stops flashing and the trouble memory clears Certifications and Approvals The detectors are designed to also comply with the requirements of Australia C Tick Region Certification Europe CE 2004 108EC EMC Directive EMC 2006 95 EC Low Voltage Directive LVD 1999 5 EC Radio equipment and Telecommunications Terminal Equip ment R amp TTE W18G W18H USA UL ANSR Intrusion Detection Unit
2. curtains of detection Tri focus optics technology also includes two pyroelectric sensors which deliver twice the standard optical gain The sensors process multiple signals to deliver precise performance virtually free of false alarms E Range Adaptive Radar The microwave transceiver automatically adjusts its detection thresholds based on input from the PIR sensors Integrating the target audience distance information from the PIR significantly reduces false alarms from the microwave Doppler radar Sensor Data Fusion Technology Sensor data fusion technology is a unique feature that uses a sophisticated software algorithm to gather signals from five sensors two pyroelectric sensors range adaptive radar a room temperature sensor and 2 ISC PDL1 W18x Professional Series Tritech Detectors Microwave Anti mask The detector sends a supervision trouble signal if microwave reflective material is placed within 30 5 cm 1 ft of the detector Supervised Microwave and PIR The detector provides single technology coverage if the microwave subsystem fails Active White Light Suppression An internal light sensor measures the level of light intensity directed at the face of the detector Sensor data fusion technology uses this information to eliminate false alarms from bright light sources cae Coverage 18 m x 25 m or 8m x 10m Installers can use a DIP switch to select 18 m x 25 m or 8 mx 10 m 60 ft x 80 ft or 25 ft x 33 ft cover
3. for TriTech alarms e Yellow LED for microwave alarms e Red LED for PIR alarms Zones Zones 86 Frequency Information Radio Frequency No alarm or setup on critical Interference RFI immunity frequencies in the range from 26 MHz to 1 GHz at 50 V m Environmental Relative Humidity 0 to 95 non condensing Temperature Operating 29 C to 55 C 20 F to 130 F and Storage For UL Certificated installations 0 C to 49 C 32 to 120 F Environmental Class Il EN 50130 5 Protection Rating IP41 IKO4 EN 60529 EN 50102 Ordering Information ISC PDL1 W18G Professional Series Tritech Detector 10 525 GHz frequency Order number ISC PDL1 W18G ISC PDL1 W18H Professional Series Tritech Detector 10 588 GHz frequency For use in France and the United Kingdom Order number ISC PDL1 W1i8H Accessories B328 Gimbal mount Bracket Mounts on a single gang box and allows rotation of a detector Wires are hidden inside Order number B328 Swiveling B335 3 low profile mount Swiveling low profile plastic mount for wall mounting The vertical swivel range is 10 to 20 while the horizontal swivel range is 25 Available in triple packs Order number B335 3 B338 Universal Ceiling mount Bracket Swiveling plastic mount for ceiling mounting The vertical swivel range is 7 to 16 while the horizontal swivel range is 45 Order number B338 5 ISC PDL1 W18x Professional Series TriTec Represented
4. Intrusion Alarm Systems SC PDL1 W18x Professional Series Tritech Detectors ISC PDL1 W18x Professional Series TriTech Detectors www boschsecurity com BOSCH Invented for life gt 18m x 25 m 60 ft x 80 ft coverage field selectable to8 mx 10 m 25 ft x 33 ft EN50131 2 4 Grade 2 compliant Sensor data fusion technology Tri focus optics technology v v v v Range adaptive radar The ISC PDL1 W18x Professional Series TriTech a white light level sensor The microcontroller analyzes Detectors are exceptionally suited for commercial and compares the sensor data to make the most indoor applications Sensor data fusion technology intelligent alarm decisions in the security industry ensures that the detectors send alarm conditions based on precise information Tri focus optics eliminate coverage gaps and respond efficiently to intruders The powerful combination of unique features in the Professional Series delivers superior catch performance and virtually eliminates false alarms The self locking two piece enclosure built in bubble level flexible mounting height and three optional mounting brackets simplify installation and reduce service time Tri focus Optics Technology Tri focus optics technology uses optics with three specific focal lengths long range coverage middle range coverage and short range coverage The detector applies the three focal lengths to 86 detection zones which combine to make 11 solid
5. age Dynamic Temperature Compensation The detector automatically adjusts PIR sensitivity to identify human intruders at critical temperatures Dynamic temperature compensation detects human body heat accurately avoids false alarms and delivers consistent catch performance at all operating temperatures Cover and Wall Tamper Switch When an intruder removes the cover or attempts to separate the detector from the wall a normally closed contact opens to alert the control panel Self adjusting LED The LED brightness adjusts automatically to the surrounding light level A blue light emitting diode LED indicates dual alarms and activates during a walk test A yellow LED indicates microwave alarms and a red LED indicates PIR alarms Remote Walk Test LED Users can type a command through a keypad a control center or programming software to remotely enable or disable the walk test LED Users can locally enable or disable the walk test LED through the DIP switch Alarm Memory Alarm memory flashes the alarm LED to indicate stored alarms for use in multiple unit applications A switched voltage from the control panel controls the alarm memory Solid State Relays Solid state relays send silent alarm output signals to provide a higher level of security and reliability An external magnet does not activate the relay The solid state relay uses less current than a mechanical relay providing longer standby capacity during a power loss
6. by Americas Europe Middle East Africa Asia Pacific Bosch Security Systems Inc Bosch Security Systems B V Robert Bosch SEA Pte Ltd Security Systems 130 Perinton Parkway P O Box 80002 11 Bishan Street 21 Fairport New York 14450 USA 5600 JB Eindhoven The Netherlands Singapore 573943 Phone 1 800 289 0096 Phone 31 40 2577 284 Phone 65 6258 5511 Fax 1 585 223 9180 Fax 31 40 2577 330 Fax 65 6571 2698 security sales us bosch com emea securitysystems bosch com apr securitysystems bosch com www boschsecurity us www boschsecurity com www boschsecurity asia Bosch Security Systems 2012 Data subject to change without notice 2607960459 en V5 13 Apr 2012
7. m 4m 6m 8m 7ft Oft Selectable Short range Coverage 8 m x 10 m 25 ft x 33 ft Oft Om 2m 4m 6m 8m10m 12m 14m 16m 18m Mounting Considerations The recommended mounting height is 2 m to 3 m 7 ft to 10 ft Use an optional B328 Gimbal mount Bracket or B335 3 Low profile Swivel mount Bracket to surface mount the detector on a flat wall or in a corner Use an optional B338 Universal Ceiling Bracket to mount the detector on the ceiling Wiring Considerations Recommended wire size is 0 2 mm to 1 mm 26 AWG to 16 AWG Parts Included Quantity BP e e N X Component Detector Flat head screws Screw anchors Nylon cable tie Pattern Mask Installation Guide Technical Specifications Electrical Power Requirements Voltage Operating Current Maximum Current Standby Outputs Relay Tamper Trouble Mechanical Enclosure Design Color Dimensions Material Indicators 9 VDC to 15 VDC lt 25 mA 13 mA Solid state relay normally closed NC contacts power supervised 3 W 125 mA 25 VDC resistance lt 100 Normally closed NC contacts with cover on rated at 25 VDC 125 mA maximum Connect tamper circuit to 24 hour protection circuit Solid state relay normally closed NC contacts White 136 mmx 69 mmx 58mm 5 25 in x 2 75 in x 2 25 in High impact ABS plastic 4 ISC PDL1 W18x Professional Series Tritech Detectors Alarm Indicator Blue LED
8. s UL639 ANSR7 Intrusion Detection Units Certified for Canada cULus W18G ECO T3XISC PDL1 W18G Canada IC 1249A W18G Italy IMQ CA12 00833 G Brazil ANATEL 1282 06 1855 W18G Belgium INCERT B 509 0052 W18G INCERT B 509 0052 a China CEG 2009031901000559 W18G the Nether REQ 07223002 AA 00 W18G lands Sweden INTYG Nr11 850 W18G France AFNOR 2830390400A1 W18H Belgium INCERT B 509 0052 c W18G France AFNOR 2830390400B0 W18G 3 ISC PDL1 W18x Professional Series Tritech Detectors Installation Configuration Notes Fe Oft 7ft 13ft 20ft 26ft 33ft 39ft 46ft 52ft 59ft 4m 46ft 39ft 33ft 26ft 20ft 13ft 7ft 7ft 13ft 20ft 26ft 33ft 39ft 46ft Om 2m 4m 6m 8m 10m 12m14m 16m 18 7ft 13ft 20ft 26ft 33ft 39ft 46ft 52ft 59 m ft 10ft Om Oft Om 2m 4m 6m 8m10m 12m 14m 16m18m Oft 7ft 13ft 20ft 26ft 33ft 39ft 46ft 52ft 59ft 2m 7ft 0m Long range Coverage 18 m x 25 m 60 ft x 80 ft Oft 7ft 13ft 20ft 26ft 6m 20ft 4m Ae 13ih WD 2m WH Tf ZY a ot 77 om r oft om SS L 7ft 4m E 13ft S 6m 20ft 0m 2m 4m 6m 8m Oft 7ft 13ft 20ft 26ft 3m 10ft om oft 0m 2m 4m 6m 8m Oft 7ft 13ft 20ft 26ft 2m 0m 0m 2
Download Pdf Manuals
Related Search
Related Contents
VG2030m-1 (VS11234) Service Manual treadmill owner`s manual manuel d`utilisation du 電池ラベルを変更します。 User`s Manual - Embedded Artists Manual - Omnio Technologies OWI AMP-IC5 Speaker User Manual 大谷処理場精密機能検査報告書 Die Glasplattennegativsammlung der AEG Design House 560037 Instructions / Assembly Copyright © All rights reserved.