Home
Tripp Lite SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS w/ Battery
Contents
1. events listed e Dynamic battery management screen optimizes battery function to lengthen service life and allow cold restart of the UPS e Built in RS 232 communication port works with included PowerAlert Software to provide shutdown commands and reporting on a single server e Accessory slot accepts an optional internal SNMP card Model SNMPWEBCARD for remote shutdowns reboots and more e Emergency Power Off button turns UPS output OFF and disables Bypass output e Built in Emergency Power Off EPO dry contact interface supports remote emergency shutdown in large facilities Specifications OUTPUT Output Volt Amp Capacity VA 80000 Output Watt Capacity Watts 64000 Nominal Output Voltage s 220 380V 230 400V 240 415V 3 Phase Wye Supported Output Nominal Voltage 220 380V 230 400V or 240 415V AC 3 phase 4 wire ground wye 2 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Maintains pure sine wave output at all times regulated within 1 of nominal output voltage with less than 3 total harmonic distortion using IGBT Inverter Output Frequency Regulation Regulates line frequency at 50 or 60 Hz 05 Hz INPUT Output Voltage Regulation BATTERY Expandable Battery Runtime ln aaa runtime with additional stand alone external battery modules Models BP480V26B and DC System Voltage VDC 240VDC Full Load Runtime 3 5 minutes 64 000w with included batter
2. hardwired external battery e Warranty information compartment required for UPS operation backup battery support order separately Battery runtime can be extended with additional stand alone hardwired external battery modules A manual bypass breaker and an automatic bypass function ensure 100 availability of connected equipment by safely passing through AC power if the UPS requires maintenance A built in RS 232 communication port works with included PowerAlert Software to provide shutdown commands and reporting on a single server An accessory slot accepts an optional internal SNMP card Model SNMPWEBCARD for remote shutdowns reboots and more Front panel combination LCD LED display alerts users to a variety of UPS operational modes and conditions The LCD display includes a real time event log screen with up to 500 events listed A dynamic battery management screen optimizes battery function to lengthen service life and allow 1 5 Tripp Lite 1111 W 35th Street 6 Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com cold restart of the UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval An Emergency Power Off button turns the UPS output OFF and disables Bypass output A built in Emergency Power Off EPO dry contact interface supports remote emergency shutdown in large facilities Features e N 1 configuration If maintenance is required four self contained redundant 20
3. DC power and then resynthesizes it back into AC power with a pure sine wave Perfectly regulated continuous sine wave output with double conversion operation Runtime is expandable via additional external battery cabinet options Applications e Ideal for protecting mission critical equipment in computing networking or telecommunications environments zero transfer time assures compatibility with all equipment types High input power factor advanced IGBT inverter technology and Digital Signal Processor DSP technology produce less than 3 input total harmonic Package Includes e SU80KX UPS System e BP480V40C external battery pack e PowerAlert Software e Instruction manual distortion THDi With low THDi generators run cooler and last longer allowing managers to save installation costs by installing a generator with a capacity equal to the equipment load 1 1 ratio Extremely efficient operation up to 97 saves money by lowering electricity consumption Hardwire input and output connections support a variety of permanent or PDU style power connections The SU80KX features 220 380V 230 400V or 240 415V AC 3 phase 4 wire ground wye input and output It also features a wide input voltage correction range 173 300V 276 477V AC Frequency is 50 or 60 Hz auto selectable SU80KX power modules are housed in a single small footprint tower compartment Included battery module Models BP480V40C are housed in a separate stand alone
4. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com TRIPP LITE Highlights e 80 000 VA 80kVA 3 phase tower UPS w external battery SmartOnline 80kVA Modular 3 Phase UPS System On line Double Conversion International UPS w Battery ae MODEL NUMBER SU80KX 40C e N 1 redundant modular architecture helps assure 100 availability e 1 1 parallel capability allows for system redundancy or increased capacity e Low THDi reduces installation costs by permitting 1 1 generator sizing e 3 phase hardwire 220 380V 230 400V or 240 415V AC 3 phase 4 wire ground wye input output e IGBT technology and zero transfer time on line Description Tripp Lite s SU80KX 80kVA SmartOnline Modular 3 Phase Intelligent True On Line UPS System provides 100 system availability with N 1 modular architecture and 1 1 parallel capability In N 1 configuration the SU80KX provides four self contained redundant 20kVA power modules that can be hot swapped load remaining powered if maintenance is required In 1 1 configuration two SU80KX models connected in parallel can provide fail safe redundancy two 80kVA models supporting a 80kVA load or increased capacity two 80kVA models supporting a 160kVA load The SU80KX provides mission critical equipment with the highest level of power protection available Large capacity 80 000VA 64 000W UPS continually converts incoming AC power into filtered
5. kVA power modules can be hot swapped with the load remaining powered e 1 1 configuration Two SU80KX can be connected in parallel to provide either fail safe redundancy or increased capacity e High input power factor advanced IGBT inverter technology and Digital Signal Processor DSP technology produce low input total harmonic distortion THDi e Low THDi less than 3 reduces installation costs by allowing 1 1 generator sizing e Extremely efficient operation up to 97 saves money by reducing electricity consumption e True on line double conversion UPS with IGBT technology provides pure sine wave AC output at all times e Maintains continuous operation with zero transfer time through blackouts voltage fluctuations and surges e Removes harmonic distortion electrical impulses frequency variations and other hard to solve power problems e 80 000VA 64 000W power capacity with 3 phase hardwire input output connections e Wide input voltage correction range 173 300V 276 477V AC e Precision 1 output voltage regulation e Included battery module Model BP480V40C are housed in a separate stand alone hardwired external battery compartment required for UPS operation backup battery support order separately e Battery runtime can be extended with additional stand alone hardwired external battery modules Models BP480V26B and BP480V40C order separately e Front panel combination LCD LED display includes a real time event log screen with up to 500
6. tains continuous operation without using battery power during overvoltages to 276 477V AC 3 phase 4 wire Power wye reducing output within 1 of nominal Above this point output is maintained utilizing reserve battery power SPECIAL FEATURES Cold Start Inverter can be cold started via the control panel to enable temporary AC output during a power failure CERTIFICATIONS Certifications CE EN62040 1 1 WARRANTY Product Warranty Period 2 year limited warranty International Product Warranty Period Mexico 1 year limited warranty hte Warranty Period Puerto 2 year limited warranty Optional Coverage Extended warranties and on site service contracts available for select opportunities contact Tripp Lite for details 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 5 5
7. tional conditions low battery overload shutdown bypass and more Front Panel LCD Yes 3 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SURGE NOISE SUPPRESSION AC Suppression Joule Rating 5950 PHYSICAL Installation Form Factors Supported Tower with Included Accessories Shipping Dimensions hwd in 55 x 28 5 x 42 5 UPS 76 3 x 28 8 x 45 8 external battery cabinet Shipping Dimensions hwd cm 139 7 x 72 39 x 107 95 Shipping Weight Ibs 687 8 UPS 1960 Ibs external battery cabinet Shipping Weight kg 312 3 UPS 882 external battery cabinet Unit Dimensions hwd in 46 x 20 5 x 33 7 UPS 67 x 20 5 x 33 7 external battery cabinet ENVIRONMENTAL COMMUNICATIONS LINE BATTERY TRANSFER Transfer Time Line Power to Zero transfer time True on line UPS continuously converts incoming AC to DC then back to AC When line power Battery Mode is interrupted UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power 4 5 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Low Voltage Transfer to Battery Maintains continuous operation without using battery power during brownout undervoltage conditions to 173 300V Power AC 3 phase 4 wire wye Below this point output is maintained utilizing reserve battery power High Voltage Transfer to Battery Main
8. y pack Half Load Runtime 9 6 minutes 32 000w with included battery pack Battery Pack Accessory Optional External battery modules Models BP480V26B and BP480V40C Typical Battery Lifespan 3 6 years depending on usage Expandable Runtime Yes VOLTAGE REGULATION Voltage Regulation Description raSi double conversion process enables UPS to maintain output voltage within 1 of nominal voltage at all Overvoltage Correction Maintains continuous operation without using battery power during overvoltages to 276 477V AC 3 phase 4 wire wye reducing output within 1 of nominal Maintains continuous operation without using battery power during brownout undervoltage conditions to 173 300V Brownout Correction AC 3 phase 4 wire wye USER INTERFACE ALERTS amp CONTROLS Selectable LCD Display Displays Real Time Event Log with up to 500 events listed Also displays a wide range of Front Panel LEDs UPS operational and fault warning conditions including operational mode alarm shutdown conditions input output voltage frequency battery voltage load percentage and more 4 LED Display Displays normal AC input on battery power bypass input and fault conditions ON button turns UPS inverter on OFF button turns UPS inverter off LCD Display Control Buttons browse through Switches and select items displayed on LCD screen EPO Emergency Power Off button turns UPS output off and disables Bypass output Audible Alarm Alarms signal a variety of opera
Download Pdf Manuals
Related Search
Related Contents
MANUAL DE USUARIO Télécharger la Valise pédagogique MANUEL D`UTILISATION CU WAGNER Cantabria CA2001 y CA2002 REMKO AMT - F. Schünke Tecumseh AVC5538EXN Performance Data Sheet 保 証 書 BINHAS Documents COACHING.pmd Copyright © All rights reserved.
Failed to retrieve file