1. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com TRIPP LITE Highlights e 48V DC or 208 230V selectable AC input 208 230V 50 60 Hz pure sine wave output hardwired e 6000 waits continuous 9000 watts OverPower and 12000 watts DoubleBoost inverter output PowerVerter APS X 6000W 48VDC 208 230V Inverter Charger with Line Interactive AVR Hardwired MODEL NUMBER APSX6048VRNET e 3 stage 23 90 amp selectable wet dry cell battery charger Auto Transfer Switching Automatic Voltage Regulation e DB9 communication port for SNMPWEBSOLOHV management e Excellent for alternative power and standby power needs Applications e Ideal for RVs over the road Description trucking conversion vans and Tripp Lite s APSX6048VR DC to AC inverter with automatic line to battery transfer and integrated charging fleet service vehicles a system serves as an extended run UPS a standalone power source or an inverter Supplies up to 6000 watts of standalone alternative power continuous 208 or 230V sine wave AC power from any 48V battery or automotive DC source When hardwire AC source for off grid alternative input is energized commercial power passes through to connected equipment and the battery set is recharged tetas energy or export applications via 3 stage 23 90 amp charging system In UPS mode the APS system responds to blackouts and severe and as an uninterrup
2. ic Generator Starter jack enables user configuration of automatic generator start up as inverter batteries drop to 23 0 VDC and generator shutoff as inverter batteries are recharged to 28 2 VDC Remote battery temperature sensing connection function prolongs battery life by adjusting the charge float voltage level based on battery temperature DB9 communication port for SNUPWEBSOLOHV management Specifications General Info RoHS OVERVIEW Style Heavy duty with built in battery charger OUTPUT Frequency Compatibility 50 60 Hz Output Receptacles Hardwire Output Watts 6000 Continuous Output Capacity Watts 6000 Peak Output Capacity Watts 12000 Output Nominal Voltage 208 230V LINE POWER AC Maintains 208 230V nominal sine wave output from line power source INVERTER POWER SUPE OaE RE AC Maintains sine wave output voltage of 208 230 VAC 5 Output Frequency Regulation 50 60 Hz 0 3 Hz INPUT Nominal Input Voltage s Supported 208V AC 230V AC DC INPUT Requires 48VDC input source capable of delivering 138A for the required duration when used at full Recommended Electrical Service continuous capacity DC requirements increase during OverPower and DoubleBoost operation For automotive applications professional hardwire installation with 250A minimum battery system fusing is recommended Maximum Input Amps Watts A Full continuous load 145A at 48VDC AC INPUT 30 amps at 208 230VAC with ful
3. ine power to battery power to maintain continuous AC power to connected loads PHYSICAL ENVIRONMENTAL Relative Humidity 0 95 non condensing LINE BATTERY TRANSFER 3 4 Transfer Time Line Power to Battery Mode Low Voltage Transfer to Battery Power High Voltage Transfer to Battery Power SPECIAL FEATURES Load Sensing Remote Control Capability TVSS Grounding CERTIFICATIONS Certifications WARRANTY Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Dip switch selectable 20 millisecond full cycle 10 millisecond half cycle transfer times which are compatible with many computers servers and networking equipment verify transfer time compatibility of loads for UPS applications In 230V AC auto mode inverter charger switches to battery mode as line voltage drops to 170V AC user adjustable to 180V In 208V AC auto mode inverter charger switches to battery mode as line voltage drops to 165V user adjustable to 175V see manual In 230V AC auto mode inverter charger switches to battery mode as line voltage increases to 260V user adjustable to 270 see manual In 208V AC auto mode inverter charger switches to battery mode as line voltage increases to 235V user adjustable to 245V see manual Optional load sense function enables automatic inverter shutoff and startup as connected equipment is powered off and on Front panel load sense poten
4. l inverter and charger Input Connection Type DC INPUT Set of DC bolt down terminals AC INPUT Hardwire via built in terminal strip with cover plate 2 4 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Fcc A Kg Voltage Compatibility VAC 208 230 Voltage Compatibility VDC 8 BATTERY Expandable Battery Runtime Runtime is expandable with any number of user supplied wet or gel type batteries DC System Voltage VDC 48 Battery Pack Accessory Optional 98 121 sealed lead acid battery optional Battery Charge Selectable 23 90 amp VOLTAGE REGULATION Voltage Regulation Description Includes automatic voltage regulation to correct brownouts and over voltages back to usable levels Overvoltage Correction Over voltages are automatically reduced by 10 Brownout Correction Brownouts are automatically boosted by 10 and 20 USER INTERFACE ALERTS amp CONTROLS Set of 6 LEDs offer continuous status information on load percentage 6 levels reported and battery charge level 7 Front Panel LEDs levels reported See manual for sequences 3 position on off remote switch enables simple on off power control plus auto remote setting that enables distant on off control of the inverter system when used in conjunction with optional APSRM4 accessory when used in Switches inverter mode In AC uninterruptible power mode auto remote setting enables automatic transfer from l
5. pplications Tripp Lite recommends its APS Truck Inverter Chargers Package Includes e APSX6048VRNET Inverter Charger e Instruction manual with warranty information e Double Boost output supports momentary start up loads up to 200 of the continuous rating for up to 10 seconds see specification chart OverPower output supports longer duration overloads to 150 for up to 60 seconds e 3 stage selectable 23 90 amp battery charger with adjustable settings for wet gel battery types 1 4 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Set of 6 front panel LEDs display continuous status information Set of 4 dip switches support AC input selection of 230V selectable 50 60Hz frequency and selectable full or half cycle transfer times Set of 4 dip switches support wet gel battery charging profiles adjustable 260 270V 230V high voltage auto transfer during overvoltages and selectable 150 60V 170 180V 230V AC low voltage auto transfer during brownouts Set of 4 additional dip switches support battery equalization program and battery charger low high settings Automatic overload and thermal overheating shutoff Front panel remote control connector enables remote off on switching APSRM4 sold separately Load sensing control dial enables adjustable load threshold required to automatically turn the inverter on and off in DC mode as load conditions change Automat
6. tible power voltage fluctuations with a near instantaneous automatic transfer to battery derived AC output Includes a set of a P supply UPS NOTE For sump high current DC input terminals for simple installation user supplies batteries and cabling see owner s manual for recommendations Passes sine wave utility or generator power during battery charging and UPS line power operation and sine wave AC output in inverter and UPS backup modes Built in Automatic Voltage Regulation AVR corrects line power AC brownouts and overvoltages without using battery power during battery charging and UPS standby modes Reliable large transformer design with frequency control powers resistive electronic loads or large inductive motors compressors and other items with high current needs on startup Optional APSRM4 wired remote power switch with full status LEDs provides remote power inverter on off switching and continuous status information part APSRM4 sold separately Supports an unlimited amount of runtime with any number of user supplied batteries connected Highly adaptable to a variety of applications and site conditions with adjustable charger settings for wet gel battery types and selectable line to battery power transfer voltages DB9 communication port for SNUPWEBSOLOHV management Features e Supports 208 230V AC output from a 208 230V AC line power source or 48V DC battery source e 6000W continuous sinewave AC output in inverter mode pump a
7. tiometer can be set to shutoff or turn on inverter power in response to loads of any level up to 150 watts Main grounding lug connects inverter charger to earth or vehicle chassis ground RoHS compliant Product Warranty Period Worldwide 2 year limited warranty 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 414