1. Ajaj CISCO Data Sheet Cisco Nexus 7000 Series Switches Product Overview Cisco Nexus 7000 Series Switches combine high levels of scalability with operational flexibility Cisco Nexus 7000 Series Switches provide the foundation for Cisco Unified Fabric They are a modular data center class product line designed for highly scalable 1 10 40 100 Gigabit Ethernet networks with a fabric architecture that scales beyond 17 terabits per second Tbps Designed to meet the requirements of the most mission critical data centers the switches deliver continuous system operation and virtualized pervasive services The Cisco Nexus 7000 Series is based on the proven Cisco NX OS Software operating system with enhanced features to deliver real time system upgrades with exceptional manageability and serviceability The first in the next generation of switch platforms the Cisco Nexus 7000 Series Figure 1 provides integrated resilience combined with features optimized specifically for the data center for availability reliability scalability and ease of management Figure 1 Cisco Nexus 7000 Series Features and Benefits Coupled with Cisco NX OS the Cisco Nexus 7000 Series delivers a comprehensive set of features with nonstop operation in four chassis form factors e 18 slot chassis with 18 front accessible module slots and side to side airflow in a compact horizontal form factor with purpose built integrated cable management e 10 slot chassis wi
2. EN300 386 NEBS criteria levels SR 3580 NEBS Level 3 GR 63 CORE issue 3 and GR 1089 CORE issue 4 Verizon NEBS compliance Telecommunications Carrier Group TCG Checklist Qwest NEBS requirements Telecommunications Carrier Group TCG Checklist ATT NEBS requirements ATT TP76200 level 3 and TCG Checklist e ETSI ETSI 300 019 1 1 Class 1 2 Storage ETSI 300 019 1 2 Class 2 3 Transportation ETSI 300 019 1 3 Class 3 2 Stationary Use Reduction of Hazardous Substances ROHS 5 UL CSA IEC EN 60950 1 AS NZS 60950 Environmental standards Safety Warranty Cisco Nexus 7000 Series Switches come with the standard Cisco 1 year limited hardware warranty Software Requirements All Cisco Nexus 7000 Series chassis are supported by Cisco NX OS Software e The 4 slot chassis requires Cisco NX OS Software Release 6 1 2 or later e The 9 slot chassis requires Cisco NX OS Software Release 5 2 or later e The 10 slot chassis requires Cisco NX OS Software Release 4 0 or later e The 18 slot chassis requires Cisco NX OS Software Release 4 1 or later For the latest information about recommended releases see http www cisco com en US docs switches datacenter sw nx os recommended _releases recommended _nx os releases html 2012 2014 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 6 of 8 Ordering Information To place an order visit the Cisco Ordering homepage To download
3. IPv4 unicast in combination with supervisor and fabric modules OIR of all redundant components supervisor and fabric modules power supplies and fan trays Supports SNMPv3 v2c and v1 see Cisco NX OS Software release notes for details about specific MIB 2012 2014 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Cisco Nexus 7000 10 Slot Switch Supports all Cisco Nexus 7000 Series modules Supports Fabrici and Fabric2 modules Cisco NX OS Software Release 4 0 or later e Air filter e Lockable front module doors 5 76 bpps IPv4 unicast in combination with supervisor and fabric modules OIR of all redundant components Supervisor and fabric modules power supplies and fan trays Supports SNMPv3 v2c and v1 see Cisco NX OS Software release notes for details about specific MIB Cisco Nexus 7000 18 Slot Switch Supports all Cisco Nexus 7000 Series modules Supports Fabrici and Fabric2 modules Cisco NX OS Software Release 4 1 or later Lockable front module door 11 5 bpps IPv4 unicast in combination with supervisor and fabric modules OIR of all redundant components supervisor and fabric modules power supplies and fan trays Supports SNMPv3 v2c and v1 see Cisco NX OS Software release notes for details about specific MIB Page 4 of 8 Network management Programming interfaces Physical specifications Environmental specifi
4. dcservices For More Information For more information about the Cisco Nexus 7000 Series visit the product homepage at http www cisco com go nexus or contact your local account representative Ajai Americas Headquarters Asia Pacific Headquarters Europe Headquarters Cisco Systems Inc Cisco Systems USA Pte Ltd Cisco Systems International BY Amsterdam San Jose CA Singapore The Netherlands Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website at www cisco com go offices Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and or its affiliates in the U S and other countries To view a list of Cisco trademarks go to this URL www cisco com go trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 1110R Printed in USA C78 437762 09 02 14 2012 2014 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 8 of 8
5. supply slots Dimensions H x W x D 36 5 x 17 3 x 33 1 in 92 7 x 43 9 x 84 1 cm Chassis depth including cable management and chassis doors is 38 in 96 5 cm Unit is rack mountable in a standard 19 inch 482 6 mm EIA rack Weight e Chassis only 200 lb 90 kg e Fully configured 516 Ib 235 kg Power requirements 110 to 240 VAC Supports 6 to 7 5 kW AC and DC power supplies Airflow direction Bottom front of chassis to top back Operating temperature 32 to 104 F 0 to 40 C Operational relative humidity 5 to 90 noncondensing Operating altitude 500 to 13 123 ft agency certified 0 to 6500 ft Seismic Zone 4 per GR63 Floor loading 190 Ib per sq ft Operational vibration GR63 Section 5 4 2 ETS 300 019 1 3 Class 3 1 Section 5 5 Storage altitude 1000 to 30 000 ft Storage temperature 40 to 158 F 40 to 70 C e Storage relative humidity 5 to 95 noncondensing support Cisco DCNM 4 1 or later XML Scriptable CLI Cisco DCNM 4 1 web services Usable rack space 25RU 18 slot chassis 2 dedicated supervisor modules and 16 I O modules 5 fabric module slots 4 power supply slots Dimensions H x W x D 43 5 x 17 3 x 33 1 in 110 5 x 43 9 x 84 1 cm Chassis depth including cable management and chassis doors is 38 in 96 5 cm Unit is rack mountable in a standard 19 inch 482 6 mm EIA rack Weight e Chassis only 187 Ib 85 kg F
6. 00 Series is enabled by the powerful combination of high density and performance support for device virtualization and comprehensive reliability and availability features This consolidation increases the power efficiency by reducing wasted power from multiple partially loaded and inflexible systems Product Specifications Table 1 lists the product specifications for the Cisco Nexus 7000 Series chassis Table 1 Product Specifications Product compatibility Software compatibility Options Performance Reliability and availability MIBs Cisco Nexus 7000 4 Slot Switch Supports the following Cisco Nexus 7000 Series Supervisor and I O modules N7K SUP2 N7K SUP2E M224XP 23L M206FQ 23L M202CF 22L M132XP 12L M148GS 11L M148GT 11L M108X2 12L F248XP 25 F248XT 25 Does not use fabric modules Cisco NX OS Software Release 6 1 2 Or later Lockable front module door 1 44 billion packets per second bpps IPv4 Unicast in combination with supervisor module and built in fabric Online insertion and removal OIR of all redundant components supervisor modules power supplies and fan trays Supports Simple Network Management Protocol SNMP Versions 3 2c and 1 see Cisco NX OS Cisco Nexus 7000 9 Slot Switch Supports all Cisco Nexus 7000 Series supervisor and 1 O modules Supports Fabric2 modules Cisco NX OS Software Release 5 2 or later Lockable front module door 5 04 bpps
7. 7010 Chassis Power Supply Blank Slot Cover Cisco Nexus 7018 Chassis Power Supply Blank Slot Cover with Handle N7K C7018 RMK N7K C7018 CAB TOP N7K C7018 FD MB N7K C7018 BSK N7K C7018 F BLANK N7K SUP BLANK N7K MODULE BLANK N7K CLK BLANK N7K 3KPS BLANK H N7K PS BLANK H N7K PS BLANK N7K PS BLANK H Service and Support Cisco offers a wide range of services to help accelerate your success deploying and optimizing Cisco Nexus 7000 Series Switches in your data center Our innovative services are delivered through a unique combination of people processes tools and partners and are focused on helping you increase operation efficiency and improve your data center network Cisco Advanced Services use an architecture led approach to help you align your data center infrastructure with your business goals and provide long term value Cisco SMARTnet Service helps you resolve mission critical problems with direct access at any time to Cisco network experts and award winning resources With this service you can take advantage of the Cisco Smart Call Home service capability which offers proactive diagnostic information and real time alerts for your Cisco Nexus 7000 Series Switches Spanning the entire network lifecycle Cisco Services helps increase investment protection optimize network operations provide migration support and strengthen your IT expertise For more information about Cisco Data Center Services visit http www cisco com go
8. 9 slot 10 slot and 18 slot chassis and the backplane design on the 4 slot chassis support flexible technology upgrades as your needs change providing ongoing investment protection Cisco Nexus 7000 4 Slot Switch Chassis The Cisco Nexus 7000 4 Slot chassis with two I O module slots supports up to 96 x 1 and 10 Gigabit Ethernet ports 12 x 40 Gigabit Ethernet ports and 4 x 100 Gigabit Ethernet ports meeting the needs of small to medium size data centers co locations access and aggregation layer deployments high speed core deployments and smaller operation zones The Cisco Nexus 7000 4 Slot chassis also has two dedicated supervisor slots to provide full redundancy and high availability The 4 slot chassis does not require fabric modules The local I O module fabrics are connected back to back to form a two stage crossbar that interconnects the I O modules and the supervisor engines The backplane capacity is determined by the installed I O modules e Side to rear airflow increases the system density in a seven rack unit 7RU footprint optimizing the use of rack space The optimized density provides the capability to stack up to six 4 slot chassis in a 42RU rack e The fan tray with built in fan and controller redundancy helps ensure reliability of the system and support for hot swapping of fan trays The fan tray is on the top side of the chassis and draws the air from the right side of the chassis through the line card and supervisor slots and p
9. cations Software release notes for details about specific MIB support Cisco Data Center Network Manager DCNM 6 1 2 or later e XML Scriptable command line interface CLI Cisco DCNM 6 1 2 web services Usable rack space 7RU 4 slot chassis 2 dedicated supervisor modules and 2 I O modules 4 power supply slots Dimensions H x W x D 12 2 x 17 4 x 24 5 in 30 9 x 44 1 x 62 2 cm Chassis depth including cable management and chassis doors is 29 6 in 75 2 cm Unit is rack mountable in a standard 19 inch 482 6 mm Electronic Industries Alliance EIA rack Weight Chassis only 45 Ib 20 kg Fully configured 120 Ib 54 kg Power requirements 110 to 240 VAC Supports 3 kW AC DC power supplies Supports up to 6 chassis stacked in a 42RU rack Airflow direction Side to rear Operating temperature 32 to 104 F 0 to 40 C Operational relative humidity 5 to 90 noncondensing Operating altitude 500 to 13 123 ft agency certified 0 to 6500 ft Seismic Zone 4 per GR63 Floor loading 42 Ib per sq ft Operational vibration GR63 Section 5 4 2 ETS 300 019 1 3 Class 3 1 Section 5 5 Storage altitude 1000 to 30 000 ft Storage temperature 40 to 158 F 40 to 70 C Storage relative humidity 5 to 95 noncondensing Heat dissipation support Cisco DCNM 5 2 or later XML Scriptable CLI Cisco DCNM 5 2 web services U
10. es and fan trays are accessible from the back Cisco Nexus 7000 18 Slot Switch Chassis The Cisco Nexus 7000 18 Slot chassis with up to 16 I O module slots supports up to 768 x 1 and 10 Gigabit Ethernet ports 96 x 40 Gigabit Ethernet ports and 32 x 100 Gigabit Ethernet ports meeting the demands of the largest data center deployments It has two dedicated supervisor slots to provide full redundancy Side to side airflow increases the system density in a 25RU footprint optimizing the use of rack space The optimized density provides more than 16RU of free space in a standard 42RU rack for cable management and patching systems Independent variable speed system and fabric fans provide efficient cooling capacity to the entire system Fan tray redundancy features help ensure reliability of the system and support for hot swapping of fan trays I O modules and supervisor modules are accessible from the front and fabric modules power supplies and fan trays are accessible from the back Cisco Nexus 7000 Series Chassis Common Components All Cisco Nexus 7000 Series chassis have the following components Integrated cable management system designed to support the cabling requirements of a fully configured system at either or both sides of the switch allowing outstanding flexibility All system components can easily be removed with the cabling in place providing ease of maintenance tasks with little disruption A series of LEDs at the top of the chassi
11. ont Power supplies and fan trays are accessible from the back Cisco Nexus 7000 10 Slot Switch Chassis The Cisco Nexus 7000 10 Slot chassis with up to eight I O module slots supports up to 384 x 1 and 10 Gigabit Ethernet ports 48 x 40 Gigabit Ethernet ports and 16 x 100 Gigabit Ethernet ports meeting the demands of large data center deployments It has two dedicated supervisor slots to provide full redundancy Front to back airflow helps ensure that use of the Cisco Nexus 7000 10 Slot chassis addresses the requirement for hot aisle and cold aisle deployments without additional complexity The system uses dual system and fabric fan trays for cooling Each fan tray is redundant and composed of independent variable speed fans that automatically adjust to the ambient temperature helping reduce power consumption in well managed facilities while helping enable optimum operation of the switch The system design increases cooling efficiency and provides redundancy capabilities allowing hot swapping without affecting the system if either a single fan or a complete fan tray fails the system continues to operate without a significant degradation in cooling capacity The system supports an optional air filter to help ensure clean air flow through the system The addition of the air filter satisfies Network Equipment Building Standards NEBS requirements I O modules and supervisor modules are accessible from the front and fabric modules power suppli
12. ropagates it through the empty space on the left side of the chassis The air then flows up to the fan tray on the top side and finally flows out from the vent holes on the back side of the chassis e Even though Nexus 7004 does not have fabric modules fabric redundancy is still provided If the local fabric on one of the I O modules fails the entire I O module is taken offline e All modules including power supplies and the fan tray are accessible from the front Cisco Nexus 7000 9 Slot Switch Chassis e The Cisco Nexus 7000 9 Slot chassis with up to seven I O module slots supports up to 336 x 1 and 10 Gigabit Ethernet ports 42 x 40 Gigabit Ethernet ports and 14 x 100 Gigabit Ethernet ports meeting the demands of mission critical campus core and data center deployments It has two dedicated supervisor slots to provide full redundancy e Side to side airflow increases the system density in a 14RU footprint optimizing the use of rack space The optimized density provides the capability to stack up to three 9 slot chassis in a 42RU rack 2012 2014 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 2 of 8 Independent variable speed system and fabric fans provide efficient cooling capacity to the entire system Fan tray redundancy features help ensure reliability of the system and support for hot swapping of fan trays I O modules supervisor modules and fabric modules are accessible from the fr
13. s 7000 Series 10 Slot Accessories Cisco Nexus 7010 Air Filter Cisco Nexus 7000 Rack Mount Kit Cisco Nexus 7010 EMI Inlet Screen Kit Cisco Nexus 7010 Front Door Top Section including Cable Management Kit Cisco Nexus 7010 Front Door Kit Cisco Nexus 7000 Bottom Support Kit Cisco Nexus 7010 Fabric Module Blank 2012 2014 Cisco and or its affiliates All rights reserved This document is Cisco Public Information N7K C7009 N7K C7009 N7K C7009 FAN N7K C7004 N7K C7004 N7K C7004 FAN N7K C7010 N7K C7010 N7K C7010 FAN S N7K C7010 FAN F N7K C7018 N7K C7018 N7K C7018 FAN N7K C7004 RMK N7K C7004 FD MB N7K C7004 AFLT N7K C7009 RMK N7K C7009 CAB TOP N7K C7009 FD MB N7K C7009 BSK N7K C7009 F BLANK N7K C7009 CMK N7K C7010 AFLT N7K RMK N7K C7010 EMI SC N7K C7010 FD TOP N7K C7010 FD MB N7K BSK N7K FAB BLANK Page 7 of 8 Product Name Part Number Cisco Nexus 7000 Series 18 Slot Accessories Cisco Nexus 7018 Rack Mount Kit Cisco Nexus 7018 Front Top Section and Cable Mgmt Kit Cisco Nexus 7018 Front Door Kit Cisco Nexus 7018 Bottom Support Kit Cisco Nexus 7018 Fabric Module Blank Blank Panel Covers Cisco Nexus 7000 Series Supervisor Blank Slot Cover Cisco Nexus 7000 Series Module Blank Slot Cover Cisco Nexus 7000 Series Network Clock Card Blank Cisco Nexus 7000 Series 3 KW Power Supply Blank Slot Cover with Handle Cisco Nexus 7009 Chassis Power Supply Blank Slot Cover with Handle Cisco Nexus
14. s provide a clear summary of the status of the major system components alerting operators to the need to conduct further investigation These LEDs report the power supply fan fabric supervisor and I O module status 2012 2014 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 3 of 8 e A purpose built optional front module door provides protection from accidental interference with both the cabling and modules installed in the system The transparent front door allows easy observation of cabling and module indicators and status lights without any need to open the doors reducing the likelihood of faults caused by human interference The door supports a dual opening capability for flexible operation and cable installation while fitted The door can easily be completely removed for both initial cabling and day to day management of the system Energy Efficient Design The Cisco Nexus 7000 Series uses power supplies that are up to 90 percent efficient so less power is wasted as heat and more power is available for the system to use than with typical power supplies The fan modules in the chassis adjust to compensate for changing thermal characteristics At lower speeds they use less power In the 9 slot chassis the fan tray is designed to completely turn off the power for a row of fans when the corresponding slots are unused Consolidation of multiple switches in the Cisco Nexus 70
15. sable rack space 14RU 9 slot chassis 2 dedicated supervisor modules and 7 I O modules 5 fabric module slots 2 power supply slots Dimensions H x W x D 24 5 x 17 3 x 24 in 62 2 x 43 9 x 61 cm Chassis depth including cable management and chassis doors is 29 in 73 7 cm Unit is rack mountable in a standard 19 inch 482 6 mm EIA rack Weight e Chassis only 100 Ib 45 kg e Fully configured 300 Ib 136 kg Power requirements 110 to 240 VAC Supports 6 to 7 5 kW AC and DC power supplies Supports up to 3 chassis stacked in a 42RU rack Airflow direction Side to side Operating temperature 32 to 104 F 0 to 40 C Operational relative humidity 5 to 90 noncondensing Operating altitude 500 to 13 123 ft agency certified 0 to 6500 ft Seismic Zone 4 per GR63 Floor loading 104 Ib per sq ft Operational vibration GR63 Section 5 4 2 ETS 300 019 1 3 Class 3 1 Section 5 5 Storage altitude 1000 to 30 000 ft Storage temperature 40 to 158 F 40 to 70 C Storage relative humidity 5 to 95 noncondensing Heat dissipation 2012 2014 Cisco and or its affiliates All rights reserved This document is Cisco Public Information support Cisco DCNM 4 0 or later e XML Scriptable CLI Cisco DCNM 4 0 web services Usable rack space 21RU 10 slot chassis 2 dedicated supervisor modules and 8 I O modules 5 fabric module slots 3 power
16. software visit the Cisco Software Center Table 2 provides ordering information Table 2 Ordering Information Product Name Part Number System Cisco Nexus 7000 Series 9 Slot chassis including Fan Trays No Power Supply Cisco Nexus 7000 Series 9 Slot chassis No Fan Trays No Power Supply Cisco Nexus 7000 Series 9 Slot Fan Tray Spare Cisco Nexus 7000 Series 4 Slot Chassis including Fan Tray Cable Management Kit No Power Supply Cisco Nexus 7000 Series 4 Slot Chassis including Fan Tray Cable Management Kit No Power Supply Cisco Nexus 7000 Series 4 Slot Fan Tray Spare Cisco Nexus 7000 Series 10 Slot chassis including Fan Trays No Power Supply Cisco Nexus 7000 Series 10 Slot chassis including Fan Trays No Power Supply Cisco Nexus 7000 Series 10 Slot System Fan Tray Spare Cisco Nexus 7000 Series 10 Slot Fabric Fan Tray Spare Cisco Nexus 7000 Series 18 Slot chassis including Fan Trays No Power Supply Cisco Nexus 7000 Series 18 Slot chassis No Fan Trays No Power Supply Cisco Nexus 7000 Series 18 Slot Fan Tray Spare Cisco Nexus 7000 Series 4 Slot Accessories Cisco Nexus 7004 Rack Mount Kit Cisco Nexus 7004 Front Door Kit Cisco Nexus 7004 Air Filter Cisco Nexus 7000 Series 9 Slot Accessories Cisco Nexus 7009 Rack Mount Kit Cisco Nexus 7009 Front Top Section and Cable Mgmt Kit Cisco Nexus 7009 Front Door Kit Cisco Nexus 7009 Bottom Support Kit Cisco Nexus 7009 Fabric Module Blank Cisco Nexus 7009 Center Mount Kit Cisco Nexu
17. th 10 front accessible vertical module slots and front to back airflow and an integrated cable management system 2012 2014 Cisco and or its affiliates All rights reserved This document is Cisco Public Information Page 1 of 8 e 9 slot with 9 front accessible module slots and side to side airflow in a compact horizontal form factor with purpose built integrated cable management e 4 slot chassis with all front accessible module slots and side to back airflow in a small form factor with purpose built integrated cable management All Cisco Nexus 7000 Series chassis use a passive mid plane architecture providing physical connectors and copper traces for interconnecting the fabric modules and the I O modules for direct data transfer All intermodule switching is performed via the crossbar fabric ASICs on the individual I O modules and fabric modules In the case of Cisco Nexus 7004 chassis since there are no fabric modules the mid plane provides the connectors and traces to interconnect the fabric ASICs on the I O modules directly A scalable fully distributed fabric architecture composed of up to five fabric modules combined with the chassis midplane delivers up to 550 Gbps per slot for 8 8 Tops 9 9 Tbps and 18 7 Tbps of forwarding capacity in the 9 slot 10 slot and 18 slot switches respectively The 4 slot chassis delivers up to 1 92 Tbps of forwarding capacity in combination with the built in fabric system The midplane design on the
18. ully configured 696 Ib 316 kg Power requirements 110 to 240 VAC Supports 6 to 7 5 kW AC and DC power supplies Airflow direction Side to side Operating temperature 32 to 104 F 0 to 40 C Operational relative humidity 5 to 90 noncondensing Operating altitude 500 to 13 123 ft agency certified 0 to 6500 ft Seismic Zone 4 per GR63 Floor loading 190 Ib per sq ft Operational vibration GR63 Section 5 4 2 ETS 300 019 1 3 Class 3 1 Section 5 5 Storage altitude 1000 to 30 000 ft Storage temperature 40 to 158 F 40 to 70 C Storage relative humidity 5 to 95 noncondensing Heat dissipation Page 5 of 8 Maximum 3500W per Maximum 7500W per Heat dissipation Maximum 18 000W per chassis actual chassis actual Maximum 12 000W per chassis actual dissipation will be lower dissipation will be lower chassis actual dissipation will be lower depending on the chassis depending on the chassis dissipation will be lower depending on the chassis configuration configuration depending on the chassis configuration configuration Regulatory e EMC compliance compliance FCC Part 15 CFR 47 USA Class A ICES 003 Canada Class A EN55022 Europe Class A CISPR22 International Class A AS NZS CISPR22 Australia and New Zealand Class A VCCI Japan Class A KN22 Korea Class A CNS13438 Taiwan Class A CISPR24 EN55024 EN50082 1 EN61000 3 2 EN61000 3 3 EN61000 6 1